Click here to load reader
Upload
phamtram
View
215
Download
1
Embed Size (px)
Citation preview
AC centrifugal fanbackward curved
R2E133-BH66-05
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type R2E133-BH66-05
Motor M2E052-BF
Phase 1~ 1~
Nominal voltage VAC 230 230
Frequency Hz 50 60
Type of data definition fa fa
Valid for approval / standard CE CE
Speed min-1 2800 3300
Power input W 24 27
Current draw A 0.11 0.13
Motor capacitor µF 1 1
Capacitor voltage VDB 400 400
Capacitor standard P0 (CE) P0 (CE)
Min. back pressure Pa 0 0
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 45 60
Starting current A 0.20 0.21ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unitSubject to alterations
Item no. 10277-5-9980 · Revision 78380 · Release 2014-05-08 · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanbackward curved
R2E133-BH66-05
Technical features
Mass 0.7 kg
Size 133 mm
Surface of rotor Partially cast in aluminium
Material of impeller PA plastic 6, fiberglass-reinforced
Number of blades 7
Direction of rotation Clockwise, seen on rotor
Type of protection IP 44; Depending on installation and position
Insulation class "B"
Max. permissible ambient motortemp. (transp./ storage)
+ 80 °C
Min. permissible ambient motortemp. (transp./storage)
- 40 °C
Mounting position Any
Condensate discharge holes None
Operation mode S1
Motor bearing Ball bearing
Touch current acc. IEC 60990(measuring network Fig. 4, TNsystem)
< 0.75 mA
Motor protection Thermal overload protector (TOP) wired internally
Cable exit Variable
Protection class I (if protective earth is connected by customer)
Product conforming to standard CE
Approval CCC; EAC
Item no. 10277-5-9980 · Revision 78380 · Release 2014-05-08 · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanbackward curved
R2E133-BH66-05
Product drawing
1 Connection line PVC, 4x brass lead tips crimped
2 Accessory part: Inlet nozzle 09566-2-4013, not included in the standard scope of delivery
3 Screw depth max. 5 mm
Connection screen
U1 blue Z brown U2 black
PE green/yellow
Item no. 10277-5-9980 · Revision 78380 · Release 2014-05-08 · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanbackward curved
R2E133-BH66-05
Charts: Air flow 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]320300280260240220200180160140120100806040200
qv[cfm]180160140120100806040200
p fs[
Pa]
190
185
180
175
170
165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
pfs
_E
[IN
H2O
]
0,76
0,74
0,72
0,7
0,68
0,66
0,64
0,62
0,6
0,58
0,56
0,54
0,52
0,5
0,48
0,46
0,44
0,42
0,4
0,38
0,36
0,34
0,32
0,3
0,28
0,26
0,24
0,22
0,2
0,18
0,16
0,14
0,12
0,1
0,08
0,06
0,04
0,02
0
p f s[Pa]1
2
3
4
Air performance measured as per ISO 5801Installation category A. For detailedinformation on the measuring set-up, pleasecontact ebm-papst. Suction-side noiselevels: LwA measured as per ISO 13347 /LpA measured with 1m distance to fan axis.The values given are valid under themeasuring conditions mentioned above andmay vary according to the actual installationsituation. With any deviation from thestandard set-up, the specific values have tobe checked and reviewed with the unitinstalled.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
50
50
50
50
n
min-1
2800
2710
2700
2710
Pe
W
24
25
26
26
I
A
0.11
0.11
0.11
0.11
qv
m3/h
290
235
175
115
pfs
Pa
0
50
100
130
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 10277-5-9980 · Revision 78380 · Release 2014-05-08 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC centrifugal fanbackward curved
R2E133-BH66-05
Charts: Air flow 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]380360340320300280260240220200180160140120100806040200
qv[cfm]220200180160140120100806040200
p fs[
Pa]
270
260
250
240
230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
pfs
_E
[IN
H2O
]
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
p f s[Pa]1
2
3
4
Air performance measured as per ISO 5801Installation category A. For detailedinformation on the measuring set-up, pleasecontact ebm-papst. Suction-side noiselevels: LwA measured as per ISO 13347 /LpA measured with 1m distance to fan axis.The values given are valid under themeasuring conditions mentioned above andmay vary according to the actual installationsituation. With any deviation from thestandard set-up, the specific values have tobe checked and reviewed with the unitinstalled.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
60
60
60
60
n
min-1
3300
3150
3125
3145
Pe
W
27
29
29
29
I
A
0.13
0.13
0.13
0.13
qv
m3/h
340
280
220
130
pfs
Pa
0
60
120
180
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase
Item no. 10277-5-9980 · Revision 78380 · Release 2014-05-08 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com