96
PRODUCT CATALOGUE NEWS 2013 simply perfect.

Product catalogue NEWS 2013 - MEDENTIKA · PDF file3 Dear customers and business partners, MEDENtika haS CharaCtEr. and it is this character that gives us a morally sound base. in

  • Upload
    hadiep

  • View
    224

  • Download
    1

Embed Size (px)

Citation preview

Product catalogue NEWS 2013

simply perfect.

2

Your Customer Number

3

Dear customers and business partners,

MEDENtika haS CharaCtEr. and it is this character that gives us a morally sound base. in a world that is becoming more and more focused on the laws that drive market forces, we feel that this position is not only right, but important.

What characterises Medentika is also our belief in the power of our ideas and in the innova-tive power of our products. We are Medentika – and if the Medentika label is on the pack-et, there is more than just an implant component inside, but an implant component that bears the knowledge and the experience that we have been putting into our products since Medentika was founded. We offer our customers our enthusiasm – a feature we use to perfect our products on a daily basis. We take this task seriously, but we also embrace it with passion. and the result is an original product manufactured with the highest interface precision from an extremely wide range of prosthetics.

this catalogue reflects our attitude in every single product – and it features over 400 new parts. take a look, for instance at the implant bearing, individually reamed bars, bridges and abut-ments. these solutions open up new, even more diverse treatment options for you and greater comfort and better functionality for your patients.

Yours,Jürgen kälber, Bernd Gaddum, Frank Fix and the entire Medentika team

Precision and Functionality implant Components made in Germany

4

medentiCAD®

digital options

titanium bases1. and 2. Generation

individualAbutments medenti-BASe Bridges and Bars

Medentika Titanium bases:

Suitable for a variety of indications and implant systems..

Individual, single unit titanium abutments:

Construct independently or model manually.

With Medenti-BASE®-Abutments:

Create multi-unit bar and bridge constructions. Constructed digitally or modelled manually.

With MedentiCAD bridges and bars:

Create multi-unit bridge and bar constructions with CaD/CaM.

Whether you are using hybrid abutments on a titanium base, individual titanium abutments or multiple unit bridges and bars: with MedentiCaD you have a wide range of options for creating high precision and functional prosthetics.

5

MedentiCaD bridges and bars allow you to create individual, multi-unit bridge and bar constructions with CaD/CaM on MedentiBaSE abutments.

You can either opt for bar and bridge constructions screwed directly onto MedentiBaSE abutments, or for passive-fit with bar and bridge constructions screwed with MedentiBaSE ad-hesive caps.

You can use our existing CaD system in association with our free-of-charge MedentiCaD library for bridges and bars, avoiding any further investments.

Login to MedentiCaD® to send the bridge or bar construc-tion you have made. On receipt of the construction data the bridge or bar you constructed is produced in high precision and then dispatched to you

barstitanium 2 implants CoCr 2 implants

3 implants 3 implants

4 implants 4 implants

5 implants 5 implants

6 implants 6 implants

7 implants 7 implants

8 implants 8 implants

bridgestitanium 2 implants CoCr 2 implants

3 implants 3 implants

4 implants 4 implants

5 implants 5 implants

6 implants 6 implants

7 implants 7 implants

8 implants 8 implants

medentiCAD®

Bridges and barsNEW

B-Serie6 B-Series

Products indicated with ® are registered brand names of respective manufactures.

the B-Series abutments are compatible with

Sky Bredent® implants

B-Series

LaB aNaLOG

Stainless Steel

NEW

implant connection 3,5–5,5

article Number B 50

aButMENt SCrEW

titanium ti6aL4V

torx t6

recommended torque: 25 Ncm

NEW

implant connection 3,5–5,5

article Number B 60

LaB SCrEW

red-coated

NEW

implant connection 3,5–5,5

article Number B 60 L

implant connection 3,5–5,5

NEW

The B-Series abutments are compatible with Sky Bredent® Implants B-Series

B-S

eri

es

Sky

Bre

den

7

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 25 Ncm

NEW

implant connection 3,5–5,5

article Number B 1000

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 5,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 25 Ncm

NEW

implant connection 3,5–5,5

article Number B 1100

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 25 Ncm

NEW

implant connection 3,5–5,5

article Number B 1500

SCaNBODY 2. GENEratiON

titanium, special-coated incl. Screw

for titanium Base 2. Generation and MedentiCaD abutment

for intra-oral scanning

sterilisable

NEW

implant connection 3,5–5,5

article Number B 1400

MedentiCaD-aButMENt

the customised, single-part abutment incl. abutment screw

titanium Grade 5 CF

recommended torque: 25 Ncm

NEW

implant connection 3,5–5,5

article Number B 9000

implant connection 3,5–5,5

medentiCAD®

B-Serie8 B-Series

NEW

MedentiCaD Wax uP BaSE

incl. Screw incl. Scan

Steel

attENtiON: For use on the Model only!

implant connection 3,5–5,5

article Number B 9100

implant connection 3,5–5,5

The B-Series abutments are compatible with Sky Bredent® Implants B-Series

B-S

eri

es

Sky

Bre

den

9

MedentiBaSE-aButMENt

for bars and bridges

titanium Grade 5 CF

implant connection 3,5–5,5 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5

article Number B 4000 B 4100 B 4200 B 4300 B 4400

MedentiBaSE PrOSthEtiC-COMPONENtS NEW

Bridge screw B 4600 titanium Cap B 4700 incl. Bridge screw Plastic Cap B 4710 incl. Bridge screw Gold Cap Castable B 4720 incl. Bridge screw

recommended torque: 15 Ncm

article Number B 4600 B 4700 B 4710 B 4720

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit NEW

titanium adhesive Cap short B 4800 incl. Bridge screwPlastic adhesive Casing short B 4810 incl. Modelling screwtitanium adhesive Cap long B 4820 incl. Bridge screwPlastic adhesive Casing long B 4830 incl. Modelling screw

recommended torque: 15 Ncm

article Number B 4800 B 4810 B 4820 B 4830

MedentiBaSE SCaNBODY B 4900 NEW for MedentiBaSE-aButMENt

Stainless Steel, special-coated

incl. Bridge screw

for bridges and bars

for intra-oral scanning

sterilisable

article Number B 4900

MedentiBaSE COVEr CaP B 4610 NEW

MedentiBaSE iMPLaNt PiCk uP B 4620

MedentiBaSE LaB aNaLOG 4630

MedentiBaSE SCrEW DriVEr/ratChEt M 11-6

article Number B 4610 B 4620 4630 M 11-6

MedentiBaSE Finisher Connection geometry M 17 NEW MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap B 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

article Number M 17 M 18

implant connection 3,5–5,5

medentiBASE®

B-Serie10 B-Series

medentiLOC®

attENtiON: You always require a driver hex 1,26 mm M 03-1 or M 10-1 to screw in the MedentiLOC abutments.

MedentiLOC aButMENt

titanium Grade 5 CF

titanium Nitrit Coating

one-piece

implant connection 3,5–5,5 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number B 2000 B 2100 B 2200 B 2300 B 2400

MedentiLOC aButMENt

aNGLED 15°

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection 3,5–5,5 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number B 2500-1 B 2600-1 B 2700-1 B 2800-1 B 2900-1

turNiNG iNStruMENt FOr MedentiLOC- aButMENt

StraiGht/aNGLED

Lab Screwdriver/ratchet

NEW

type MedentiLOC straight

MedentiLOC straight

MedentiLOC angled

MedentiLOC angled

article Number M 03-1 M 10-1 M 03-7 M 10-7

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type MedentiLOC straight

MedentiLOC angled

article Number 56 57

iNSErt

For machining holder prosthetic dentistry

Stainless Steel

NEW

implant connection 3,5–5,5

article Number B 40

MaChiNiNG hOLDEr PrOSthEtiC DENtiStrY M 04Stainless Steel massiveFits all seriesMaChiNiNG hOLDEr PrOSthEtiC DENtiStrY iN WOODEN tOOL BOx MB 05

Box incl. machining holder prosthetic dentistry and allen key

NEW

article Number M 04 MB 05

The B-Series abutments are compatible with Sky Bredent® Implants B-Series

B-S

eri

es

Sky

Bre

den

11

NOVaLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

B-Serie12 B-Series

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 88

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,5-5,5 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number B 5000 B 5100 B 5200 B 5300 B 5400

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

NEW

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

The B-Series abutments are compatible with Sky Bredent® Implants B-Series

B-S

eri

es

Sky

Bre

den

13

14 C-Series

implant connection 3,3 3,8 4,3

Products indicated with ® are registered brand names of respective manufactures.

the C-Series abutments are compatible to

Camlog® implants

C-Series

aButMENt SCrEW

titanium ti6aL4V

hex 1,26 mm

recommended torque: 20 Ncm

NEW

implant connection 3,3 3,8 4,3

article Number C 60 C 60 C 60

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 20 Ncm

NEW

implant connection 3,3 3,8 4,3

article Number C 1500 C 1510 C 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short C 4800 incl. Bridge screwPlastic adhesive Casing short C 4810 incl. Modelling screwtitanium adhesive base long C 4820 incl. Bridge screwPlastic adhesive base long C 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number C 4800 C 4810 C 4820 C 4830

15The C-Series abutments are compatible withCamlog® Implants C-Series

C-S

eri

es

Cam

log

®

MedentiBaSE Finisher connection geometry M 17 NEW MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap C 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

article Number M 17 M 18

NOVaLOC™ PrOCESSiNG PaCkaGE Matrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

16 C-Series

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,3 mm

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number C 5000 C 5100 C 5200 C 5300 C 5400

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,8 mm

recommended torque: 30 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number C 5010 C 5110 C 5210 C 5310 C 5410

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 4,3 mm

recommended torque: 30 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number C 5020 C 5120 C 5220 C 5320 C 5420

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

17The C-Series abutments are compatible withCamlog® Implants C-Series

C-S

eri

es

Cam

log

®

18 D-Series

implant connection 3,3 3,8/4,3

LaB aNaLOG

Stainless Steel

NEW

implant connection 3,3 3,8/4,3

article Number D 50 D 51

aButMENt SCrEW

titanium ti6aL4V

hex 1,26 mm

recommended torque: 20 Ncm

NEW

implant connection 3,3 3,8/4,3

article Number D 60 D 60

LaB SCrEW

red-coated

NEW

implant connection 3,3 3,8/4,3

article Number D 60 L D 60 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 20 Ncm

NEW

implant connection 3,3 3,8/4,3

article Number D 3500 D 3510

Products indicated with ® are registered brand names of respective manufactures.

the D-Serie abutments are compatible with

Conelog® implants

D-Series

19The D-Series abutments are compatible with Conelog® Implants D-Series

D-S

eri

es

Co

nel

og

®

implant connection 3,3 3,3 3,8/4,3 3,8/4,3

medentiCAD®

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 0,65 1,15 0,65 1,15

implant connection 3,3 3,3 3,8/4,3 3,8/4,3

article Number D 1000 D 1200 D 1010 D 1210

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 5,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 0,65 1,15 0,65 1,15

implant connection 3,3 3,3 3,8/4,3 3,8/4,3

article Number D 1100 D 1300 D 1110 D 1310

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,65 mm

recommended torque: 20 Ncm

NEW

implant connection 3,3 3,8/4,3

article Number D 1500 D 1510

SCaNBODY 2. GENEratiON

titanium, special-coated incl. Screw

for titanium Base 2. Generation and MedentiCaD abutment

for intra-oral scanning

sterilisable

NEW

implant connection 3,3 3,8/4,3

article Number D 1400 D 1410

MedentiCaD-aButMENt

the customised, single-part abutment incl. abutment screw

titanium Grade 5 CF

recommended torque: 20 Ncm

NEW

implant connection 3,3 3,8/4,3

article Number D 9000 D 9010

20 D-Series

implant connection 3,3 3,8/4,3

NEWMedentiCaD Wax uP BaSE

incl. Screw incl. Scan

Steel

attENtiON: For use on the Model only!

implant connection 3,3 3,8/4,3

article Number D 9100 D 9110

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short D 4800 incl. Bridge screwPlastic adhesive Casing short D 4810 incl. Modelling screwtitanium adhesive base long D 4820 incl. Bridge screwPlastic adhesive base long D 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number D 4800 D 4810 D 4820 D 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap D 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

implant connection 3,3 mm

two-piece incl. Screw

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number D 2500-1 D 2600-1 D 2700-1 D 2800-1 D 2900-1

21The D-Series abutments are compatible with Conelog® Implants D-Series

D-S

eri

es

Co

nel

og

®

MedentiLOC aButMENt

aNGLED 15° - tYPE 2

titanium Grade 5 CF

titanium Nitrit Coating

implant connection 3,3 mm

two-piece incl. Screw

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number D 2500-2 D 2600-2 D 2700-2 D 2800-2 D 2900-2

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

implant connection 3,8/4,3 mm

two-piece incl. Screw

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number D 2510-1 D 2610-1 D 2710-1 D 2810-1 D 2910-1

MedentiLOC aButMENt

aNGLED 15° - tYPE 2

titanium Grade 5 CF

titanium Nitrit Coating

implant connection 3,8/4,3 mm

two-piece incl. Screw

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number D 2510-2 D 2610-2 D 2710-2 D 2810-2 D 2910-2

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

22 D-Series

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,3 mm

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number D 5000 D 5100 D 5200 D 5300 D 5400

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,8/4,3 mm

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number D 5010 D 5110 D 5210 D 5310 D 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

23The D-Series abutments are compatible with Conelog® Implants D-Series

D-S

eri

es

Co

nel

og

®

24 E-Series

LaB SCrEW

red-coated

NEW

implant connection NP 3,5 rP 4,3 WP 5,0 6,0

article Number E 60 L E 61 L E 61 L E 61 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection NP 3,5 rP 4,3 WP 5,0

article Number E 3500 E 3510 E 3520

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr CaM

Products indicated with ® are regi-stered brand names of respective manufactures.

the E-Series abutments are compatible with

Nobel Biocare replace Select® implants

E-Series

implant connection NP 3,5 rP 4,3 WP 5,0 6,0

25The E-Series abutments are compatible with Nobel Biocare Replace Select® Implantat E-Series

E-S

eri

es

No

bel

Bio

care

R

epla

ce S

elec

implant connection NP 3,5 rP 4,3 WP 5,0 6,0

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 35 Ncm

NEW

implant connection NP 3,5 rP 4,3 WP 5,0

article Number E 1500 E 1510 E 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short E 4800 incl. Bridge screwPlastic adhesive Casing short E 4810 incl. Modelling screwtitanium adhesive base long E 4820 incl. Bridge screwPlastic adhesive base long E 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number E 4800 E 4810 E 4820 E 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap E 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection NP 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number E 2500-1 E 2600-1 E 2700-1 E 2800-1 E 2900-1

tYPE 2 = aNGLED OVEr CaM

26 E-Series

MedentiLOC aButMENt

aNGLED 15°- tYPE 2

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection NP 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number E 2500-2 E 2600-2 E 2700-2 E 2800-2 E 2900-2

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection rP 4,3 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number E 2510-1 E 2610-1 E 2710-1 E 2810-1 E 2910-1

MedentiLOC aButMENt

aNGLED 15° - tYPE 2

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection rP 4,3 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number E 2510-2 E 2610-2 E 2710-2 E 2810-2 E 2910-2

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

NEW

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque: 35 Ncm

NEW

implant connection NP 3,5 rP 4,3

article Number E 64 E 65

27The E-Series abutments are compatible with Nobel Biocare Replace Select® Implantat E-Series

E-S

eri

es

No

bel

Bio

care

R

epla

ce S

elec

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

28 E-Series

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection NP 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number E 5000 E 5100 E 5200 E 5300 E 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection rP 4,3 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number E 5010 E 5110 E 5210 E 5310 E 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

29The E-Series abutments are compatible with Nobel Biocare Replace Select® Implantat E-Series

E-S

eri

es

No

bel

Bio

care

R

epla

ce S

elec

30 F-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are registered brand names of respective manufactures.

the F-Series abutments are compatible with

Nobel active® implantsNobel replace® Conical Connection implants

F-Series

LaB aNaLOG

Stainless Steel

NEW

implant connection 3,0

article Number F 52

aButMENt SCrEW

titanium ti6aL4V

uG

recommended torque 3,0: 15 Ncm

NEW

implant connection 3,0

article Number F 66

LaB SCrEW

red-coated

NEW

implant connection 3,0 NP 3,5 rP 4,3/5,0

article Number F 66 L F 60 L F 61 L

implant connection 3,0 NP 3,5 rP 4,3/5,0

31The F-Series abutments are compatible withNobel Active® Implants F-Series

F-Se

rie

sN

ob

el A

ctiv

e® +

No

bel

Rep

lace

®

Co

nic

al C

on

nec

tio

n

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque 3,0: 15 Ncm recommended torque NP/rP: 35 Ncm

NEW

implant connection 3,0 NP 3,5 rP 4,3/5,0

article Number F 3520 F 3500 F 3510

medentiCAD®

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 3,5 MM

titanium

incl. abutment screw

recommended torque 3,0: 15 Ncm

NEW

Gingiva height (mm) 0,65

implant connection 3,0

article Number F 1020

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 5,5 MM

titanium

incl. abutment screw

recommended torque 3,0: 15 Ncm

NEW

Gingiva height (mm) 0,65

implant connection 3,0

article Number F 1120

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,65 mm

recommended torque 3,0: 15 Ncm recommended torque NP/rP: 35 Ncm

NEW

implant connection 3,0 NP 3,5 rP 4,3/5,0

article Number F 1520 F 1500 F 1510

SCaNBODY 2. GENEratiON

3,0: titanium, special-coated incl. Screw

for titanium base 2. Generation and MedentiCaD abutment

for intra-oral scanning

sterilisable

NEW

implant connection 3,0

article Number F 1420

implant connection 3,0 NP 3,5 rP 4,3/5,0

tYPE 2 = aNGLED OVEr EDGE

32 F-Series

implant connection 3,0 NP 3,5 rP 4,3/5,0

MedentiCaD-aButMENt

the customised, single-part abutment incl. abutment screw

titanium Grade 5 CF

recommended torque 3,0: 15 Ncm

NEW

implant connection 3,0

article Number F 9020

NEWMedentiCaD Wax uP BaSE

incl. Screw incl. Scan

Steel

attENtiON: For use on the Model only!

implant connection 3,0

article Number F 9120

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short F 4800 incl. Bridge screwPlastic adhesive Casing short F 4810 incl. Modelling screwtitanium adhesive base long F 4820 incl. Bridge screwPlastic adhesive base long F 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number F 4800 F 4810 F 4820 F 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap F 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

33The F-Series abutments are compatible withNobel Active® Implants F-Series

F-Se

rie

sN

ob

el A

ctiv

e® +

No

bel

Rep

lace

®

Co

nic

al C

on

nec

tio

n

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection NP 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number F 2500-1 F 2600-1 F 2700-1 F 2800-1 F 2900-1

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection rP 4,3/5,0 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number F 2510-1 F 2610-1 F 2710-1 F 2810-1 F 2910-1

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque NP/rP: 35 Ncm

implant connection NP 3,5 rP 4,3/5,0

article Number F 64 F 65

34 F-Series

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

35The F-Series abutments are compatible withNobel Active® Implants F-Series

F-Se

rie

sN

ob

el A

ctiv

e® +

No

bel

Rep

lace

®

Co

nic

al C

on

nec

tio

n

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection NP 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number F 5000 F 5100 F 5200 F 5300 F 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection rP 4,3/5,0 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number F 5010 F 5110 F 5210 F 5310 F 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

36 H-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are regi-stered brand names of respective manufactures.

the h-Series abutments are compatible with

Biomet 3i Certain® implants

h-Series

LaB SCrEW

red-coated

NEW

implant connection 3,4 4,1 5,0

article Number h 60 L h 60 L h 60 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 20 Ncm

NEW

implant connection 3,4 4,1

article Number h 3500 h 3510

implant connection 3,4 4,1 5,0

37The H-Series abutments are compatible withBiomet 3i Certain® Implants H-Series

H-S

eri

es

Bio

met

3i C

erta

in®

implant connection 3,4 4,1 5,0

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 20 Ncm

NEW

implant connection 3,4 4,1 5,0

article Number h 1500 h 1510 h 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short h 4800 incl. Bridge screwPlastic adhesive Casing short h 4810 incl. Modelling screwtitanium adhesive base long h 4820 incl. Bridge screwPlastic adhesive base long h 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number h 4800 h 4810 h 4820 h 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap h 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

medentiLOC®

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

tYPE 2 = aNGLED OVEr EDGE

38 H-Series

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

39The H-Series abutments are compatible withBiomet 3i Certain® Implants H-Series

H-S

eri

es

Bio

met

3i C

erta

in®

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,4 mm

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number h 5000 h 5100 h 5200 h 5300 h 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 4,1 mm

recommended torque: 20 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number h 5010 h 5110 h 5210 h 5310 h 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

40 I-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are regi-stered brand names of respective manufactures.

the i-Series abutments are compatible with

Biomet 3i® outer hex implants

i-Series

LaB SCrEW

red-coated

NEW

implant connection 3,4 4,1 5,0

article Number i 61 L i 61 L i 61 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection 3,4 4,1

article Number i 3500 i 3510

implant connection 3,4 4,1 5,0

41The I-Series abutments are compatible withBiomet 3i® outer hex Implants I-Series

I-Se

rie

sB

iom

et 3

i® o

ute

r h

ex

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,6 mm

recommended torque: 35 Ncm

NEW

implant connection 3,4 4,1 5,0

article Number i 1500 i 1510 i 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short i 4800 incl. Bridge screwPlastic adhesive Casing short i 4810 incl. Modelling screwtitanium adhesive base long i 4820 incl. Bridge screwPlastic adhesive base long i 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number i 4800 i 4810 i 4820 i 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap i 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

medentiLOC®

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

implant connection 3,4 4,1 5,0

tYPE 2 = aNGLED OVEr EDGE

42 I-Series

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

43The I-Series abutments are compatible withBiomet 3i® outer hex Implants I-Series

I-Se

rie

sB

iom

et 3

i® o

ute

r h

ex

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,4 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number i 5000 i 5100 i 5200 i 5300 i 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 4,1 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number i 5010 i 5110 i 5210 i 5310 i 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

44 K-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are reg-istered brand names of respective manufactures.

the k-Series abutments are compatible with

Nobel Biocare Brånemark® implants

k-Serie

LaB SCrEW

red-coated

NEW 3,80 Eur 3,80 Eur 3,80 Eur

implant connection 3,5 4,1 5,1

article Number k 60 L k 61 L k 62 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection 3,5 4,1

article Number k 3500 k 3510

implant connection 3,5 4,1 5,1

45The K-Series abutments are compatible withNobel Biocare Brånemark® Implants K-Series

K-S

eri

es

No

bel

Bio

care

Brå

nem

ark®

implant connection 3,5 4,1 5,1

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,6 mm

recommended torque: 35 Ncm

NEW

implant connection 3,5 4,1 5,1

article Number k 1500 k 1510 k 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short k 4800 incl. Bridge screwPlastic adhesive Casing short k 4810 incl. Modelling screwtitanium adhesive base long k 4820 incl. Bridge screwPlastic adhesive base long k 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number k 4800 k 4810 k 4820 k 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap k 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

medentiLOC®

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

tYPE 2 = aNGLED OVEr EDGE

46 K-Series

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

47The K-Series abutments are compatible withNobel Biocare Brånemark® Implants K-Series

K-S

eri

es

No

bel

Bio

care

Brå

nem

ark®

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number k 5000 k 5100 k 5200 k 5300 k 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 4,1 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number k 5010 k 5110 k 5210 k 5310 k 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

48 L-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are regi-stered brand names of respective manufactures.

the L-Series abutments are compatible with

Straumann Bone Level® implants

L-Series

aButMENt SCrEW

titanium ti6aL4V

torx t6

recommended torque: 35 Ncm

* L 63 for: L 310 r, L 1510

NEW

implant connection NC 3,3 rC 4,1/4,8 rC 4,1/4,8

article Number L 60 L 60 L 63*

LaB SCrEW

red-coated

NEW

implant connection NC 3,3 rC 4,1/4,8

article Number L 60 L L 60 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection NC 3,3 rC 4,1/4,8

article Number L 3500 L 3510

implant connection NC 3,3 rC 4,1/4,8

49The L-Series abutments are compatible withStraumann Bone Level® Implants L-Series

L-Se

rie

sSt

rau

man

n B

on

e Le

vel®

implant connection NC 3,3 rC 4,1/4,8

tYPE 2 = aNGLED OVEr EDGE

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection NC 3,3 rC 4,1/4,8

Gingiva height (mm) 1,0 0,8

article Number L1500 L 1510

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short L 4800 incl. Bridge screwPlastic adhesive Casing short L 4810 incl. Modelling screwtitanium adhesive base long L 4820 incl. Bridge screwPlastic adhesive base long L 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number L 4800 L 4810 L 4820 L 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap L 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection NC 3,3 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number L 2500-1 L 2600-1 L 2700-1 L 2800-1 L 2900-1

MedentiLOC aButMENt

aNGLED 15°- tYPE 2

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection NC 3,3 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number L 2500-2 L 2600-2 L 2700-2 L 2800-2 L 2900-2

50 L-Series

MedentiLOC aButMENt

aNGLED 15°- tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection rC 4,1/4,8 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number L 2510-1 L 2610-1 L 2710-1 L 2810-1 L 2910-1

MedentiLOC aButMENt

aNGLED 15°- tYPE 2

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection rC 4,1/4,8 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number L 2510-2 L 2610-2 L 2710-2 L 2810-2 L 2910-2

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque: 35 Ncm

implant connection NC 3,3 rC 4,1/4,8

article Number L 62 L 62

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

51The L-Series abutments are compatible withStraumann Bone Level® Implants L-Series

L-Se

rie

sSt

rau

man

n B

on

e Le

vel®

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection NC 3,3 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number L 5000 L 5100 L 5200 L 5300 L 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection rC 4,1/4,8 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number L 5010 L 5110 L 5210 L 5310 L 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

52 N-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are regi-stered brand names of respective manufactures.

the N-Series abutments are compatible with

Straumann SynOcta® implants

N-Serie

aButMENt SCrEW

titanium ti6aL4V

torx t6

recommended torque: 35 Ncm

* N 62 for:

N 310, N 320, N 410, N 420, N 810, N 820, N 910, N 920, N 1000, N 1010, N 1020, N 1100, N 1110, N 1120

NEW

implant connection NNC 3,5 NN 3,5 rN 4,8 WN 6,5 rN 4,8 WN 6,5

article Number N 65 N 60 N 61 N 61 N 62*

LaB SCrEW

red-coated

* N 62 L for:N 310, N 320, N 410, N 420, N 810, N 820,N 910, N 920, N 1000, N 1010, N 1020,N 1100, N 1110, N 1120

NEW

implant connection NNC NN 3,5 rN 4,8 WN 6,5 rN 4,8 WN 6,5

article Number N 65 L N 60 L N 61 L N 61 L N 62 L*

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection NNC 3,5 NN 3,5 rN 4,8 WN 6,5

article Number N 3530 N 3500 N 3510 N 3520

implant connection NNC 3,5 NN 3,5 rN 4,8 WN 6,5

53The N-Series abutments are compatible withStraumann SynOcta® Implants N-Series

N-S

eri

es

Stra

um

ann

Syn

Oct

implant connection NNC 3,5 NN 3,5 rN 4,8 WN 6,5 WN 6,5

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 35 Ncm

NEW

implant connection NNC 3,5 rN 4,8 WN 6,5

article Number N 1530 N 1510 N 1520

medentiBASE®

MedentiBaSE NNC 3,5

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short NNC 4800 incl. Bridge screwPlastic adhesive Casing short NNC 4810 incl. Modelling screwtitanium adhesive base long NNC 4820 incl. Bridge screwPlastic adhesive base long NNC 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number NNC 4800 NNC 4810 NNC 4820 NNC 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap NNC 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

MedentiBaSE rN 4,8

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive base N 4800 incl. Bridge screwPlastic adhesive base N 4810 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number N 4800 N 4810

MedentiBaSE Finisher connection geometry rN 4,8

MedentiBaSE Finisher screw head

Carbide

this is used to finish the fitting surfaces for the plastic cap N 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

connection geometry

screw head

article Number M 19 M 18

tYPE 2 = aNGLED OVEr EDGE

54 N-Series

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection rN 4,8 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5

article Number N 2510 N 2610 N 2710 N 2810 N 2910

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque: 35 Ncm

implant connection rN 4,8

article Number N 64

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

55The N-Series abutments are compatible withStraumann SynOcta® Implants N-Series

N-S

eri

es

Stra

um

ann

Syn

Oct

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection NNC 3,5 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5

article Number N 5030 N 5130 N 5230 N 5330 N 5430

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection rN 4,8 mm

recommended torque: 35 Ncm

NEW

Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5

article Number N 5010 N 5110 N 5210 N 5310 N 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

56 R-Series

the r-Series abutments are compatible with

Zimmer tapered Screw-Vent® implantsMiS® SEVEN implants (hexagon socket)Biohorizons® implants (hexagon socket)

r-Series

tYPE 1 = aNGLED OVEr FLat tYPE 2 = aNGLED OVEr EDGE

COMPariSON Chart Zimmer tapered Screw-Vent® / MiS® Seven / Biohorizons®

Products indicated with ® are registered brand names of respective manufactures.

Biohorizons® Platform 3,0 mm

Platform 3,5 mm

Platform 4,5 mm

Platform 5,7 mm

Implant Ø 3,00 3,80 4,60 5,80

Lab analog Ø 3,00 3,50 4,50 5,70article Number tP3ia SYia SGia SBiaimplant connection

Medentika R-Series Lab analog

XX 3,50 4,50 5,70

article Number xx r 50 r 51 r 52

Zimmer tapered Screw-Vent®

Platform 3,5 mm

Platform 4,5 mm

Platform 5,7 mm

Implant Ø 3,70 4,10 4,70 6,00

Lab analog Ø 3,50 3,50 4,50 5,70article Number ia3 ia3 ia4 ia5

implant connection

Medentika R-Series Lab analog

3,5 3,5 4,5 5,7

article Number r 50 r 50 r 51 r 52

MiS® Seven Narrow-Platform

Standard-Platform

Wide-Platform

Implant Ø 3,30 3,30 3,75 4,20 5,00 6,00

Lab analog Ø 3,30 4,20 4,20 4,20 4,50 4,50article Number MN-rSM10 MD-rSM10 MD-rSM10 MD-rSM10 MW-rSM10 MW-rSM10

implant connection

Medentika R-Series Lab analog

XX 3,50 3,50 3,50 4,50 4,50

article Number xx r 50 r 50 r 50 r 51 r 51

57Zimmer Tapered Screw-Vent® ImplantsMIS® SEVEN Implants (hexagon socket)BioHorizons® Implants (hexagon socket)

The R-Series abutmentsare compatible with R-Series

R-S

eri

es

Zim

mer

Tap

ered

Scr

ew-V

ent®

MIS

® S

even

, B

ioH

ori

zon

tYPE 2 = aNGLED OVEr EDGE

LaB SCrEW

red-coated

NEW

implant connection 3,5 4,5 5,7

article Number r 60 L r 60 L r 60 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 30 Ncm

NEW

implant connection 3,5 4,5

article Number r 3500 r 3510

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

Gingiva height 0,3 mm

recommended torque: 30 Ncm

NEW

implant connection 3,5 4,5 5,7

article Number r 1500 r 1510 r 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short r 4800 incl. Bridge screwPlastic adhesive Casing short r 4810 incl. Modelling screwtitanium adhesive base long r 4820 incl. Bridge screwPlastic adhesive base long r 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number r 4800 r 4810 r 4820 r 4830

implant connection 3,5 4,5 5,7

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap r 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

58 R-Series

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection 3,5 mm

recommended torque: 30 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number r 2500-1 r 2600-1 r 2700-1 r 2800-1 r 2900-1

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque: 30 Ncm

implant connection 3,5 4,5 5,7

article Number r 62 r 62 r 62

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing titanium PEEk

article Number 2010.601 2010.611

59Zimmer Tapered Screw-Vent® ImplantsMIS® SEVEN Implants (hexagon socket)BioHorizons® Implants (hexagon socket)

The R-Series abutmentsare compatible with R-Series

R-S

eri

es

Zim

mer

Tap

ered

Scr

ew-V

ent®

MIS

® S

even

, B

ioH

ori

zon

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,5 mm

recommended torque: 30 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number r 5000 r 5100 r 5200 r 5300 r 5400

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

60 S-Series

LaB aNaLOG

Stainless Steel

NEW

implant connection 3,0

article Number S 53

aButMENt SCrEW

titanium ti6aL4V

hex 1,26 mm

recommended torque: 3,0: 15 Ncm

NEW

implant connection 3,0

article Number S 67

LaB SCrEW

red-coated

NEW

implant connection 3,0 3,5/4,0 3,5/4,0 4,5/5,0

article Number S 67 L S 60 L S 60 L S 61 L

implant connection 3,0 3,5/4,0 4,5/5,0

Products indicated with ® are registered brand names of respective manufactures.

the S-Series abutments are compatible with

astra tech OsseoSpeed® implants

S-Series

61S-Series

S-Se

rie

sA

stra

Tec

h O

sseo

Sp

eed

®

The S-Series abutments are compatible withAstra Tech OsseoSpeed® Implants

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 3,0: 15 Ncm3,5/4,0: 20 Ncm4,5/5,0: 20 Ncm

NEW

implant connection 3,0 3,5/4,0 4,5/5,0

article Number S 3530 S 3500 S 3520

StraiGht aButMENtGiNGiVa hEiGht 1,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 3,0: 15 Ncm

NEW

abutment Ø (mm) 3,5

implant connection 3,0

article Number S 130

aNGLED aButMENt 16°GiNGiVa hEiGht 1,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 3,0: 15 Ncm

NEW

abutment Ø (mm) 3,5

implant connection 3,0

article Number S 230

medentiCAD®

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 3,0: 15 Ncm

NEW

Gingiva height (mm) 0,6

implant connection 3,0

article Number S 1030

titaNiuM BaSE FOr ZirkONiuM aButMENt 2. GENEratiON

Wax uP hEiGht 5,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 3,0: 15 Ncm

NEW

Gingiva height (mm) 0,6

implant connection 3,0

article Number S 1130

implant connection 3,0 3,5/4,0 3,5/4,0 4,5/5,0

62 S-Series

implant connection 3,0 3,5/4,0 3,5/4,0 4,5/5,0 4,5/5,0

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 3,5/4,0: 25 Ncm4,5/5,0: 25 Ncm

NEW

Gingiva height (mm) 0,6 0,6

implant connection 3,5/4,0 4,5/5,0

article Number S 1500 S 1520

SCaNBODY 2. GENEratiON

titanium, special-coated incl. Screw

for titanium base 2. Generation and MedentiCaD abutment

for intra-oral scanning

sterilisable

NEW

implant connection 3,0

article Number S 1430

MedentiCaD-aButMENt

the customised, single-part abutment incl. abutment screw

titanium Grade 5 CF

recommended torque: 3,0: 15 Ncm

NEW

implant connection 3,0

article Number S 9030

NEWMedentiCaD Wax uP BaSE

incl. Screw incl. Scan

Steel

attENtiON: For use on the Model only!

implant connection 3,0

article Number S 9130

63S-Series

S-Se

rie

sA

stra

Tec

h O

sseo

Sp

eed

®

The S-Series abutments are compatible withAstra Tech OsseoSpeed® Implants

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short S 4800 incl. Bridge screwPlastic adhesive Casing short S 4810 incl. Modelling screwtitanium adhesive base long S 4820 incl. Bridge screwPlastic adhesive base long S 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number S 4800 S 4810 S 4820 S 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap S 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

64 S-Series

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15°

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection 3,5/4,0 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number S 2500 S 2600 S 2700 S 2800 S 2900

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque: 25 Ncm

implant connection 3,5/4,0

article Number S 65

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

65S-Series

S-Se

rie

sA

stra

Tec

h O

sseo

Sp

eed

®

The S-Series abutments are compatible withAstra Tech OsseoSpeed® Implants

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,5/4,0 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number S 5000 S 5100 S 5200 S 5300 S 5400

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

66 T-Series

tYPE 1 = aNGLED OVEr FLat

DEtaiLED ViEW

Exact view of the direction of the angulation (indexing) of all angled abutments.

tYPE 2 = aNGLED OVEr EDGE

Products indicated with ® are reg-istered brand names of respective manufactures.

the t-Series abutments are compatible with

Dentsply-Friadent Frialit/xive® implants

t-Series

implant connection 3,4 3,8 4,5 5,5

LaB SCrEW

red-coated

NEW

implant connection 3,4 3,8 4,5 5,5

article Number t 60 L t 60 L t 60 L t 60 L

tEMPOrarY aButMENt

titanium Grade 5 CF

incl. abutment screw

recommended torque: 25 Ncm

NEW

implant connection 3,4 3,8 4,5

article Number t 3500 t 3505 t 3510

67T-Series

T-S

eri

es

Den

tsp

ly-F

riad

ent

Fr

ialit

/Xiv

The T-Series abutments are compatible withDentsply-Friadent Frialit/Xive® Implants

tYPE 2 = aNGLED OVEr EDGE

medentiCAD®

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 0,3 0,3 0,6 0,6

implant connection 3,4 3,8 4,5 5,5

article Number t 1500 t 1505 t 1510 t 1520

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short t 4800 incl. Bridge screwPlastic adhesive Casing short t 4810 incl. Modelling screwtitanium adhesive base long t 4820 incl. Bridge screwPlastic adhesive base long t 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number t 4800 t 4810 t 4820 t 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap t 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

68 T-Series

medentiLOC®

attENtiON: to screw in the angled MedentiLOC abutments you need a special turning instrument Driver hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection 3,4 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number t 2500-1 t 2600-1 t 2700-1 t 2800-1 t 2900-1

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection 3,8 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number t 2505-1 t 2605-1 t 2705-1 t 2805-1 t 2905-1

MedentiLOC aButMENt

aNGLED 15° - tYPE 1

titanium Grade 5 CF

titanium Nitrit Coating

two-piece incl. Screw

implant connection 4,5 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number t 2510-1 t 2610-1 t 2710-1 t 2810-1 t 2910-1

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

aNGLED

Lab Screwdriver/ratchet

type MedentiLOC angled

MedentiLOC angled

article Number M 03-7 M 10-7

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

MedentiLOC

LaB aNaLOG

Stainless Steel

NEW

type Gingiva height measuring tool altustM

MedentiLOC angled

article Number 2013.901 57

69T-Series

T-S

eri

es

Den

tsp

ly-F

riad

ent

Fr

ialit

/Xiv

The T-Series abutments are compatible withDentsply-Friadent Frialit/Xive® Implants

SCrEW for MedentiLOC-aButMENt

aNGLED

recommended torque: 25 Ncm

implant connection 3,4 3,8 4,5

article Number t 62 t 62 t 62

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

incl. mounting insert

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

70 T-Series

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,4 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number t 5000 t 5100 t 5200 t 5300 t 5400

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,8 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number t 5005 t 5105 t 5205 t 5305 t 5405

OPtiLOC™ aButMENt

titanium Nitrit Coating

one-piece

implant connection 4,5 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number t 5010 t 5110 t 5210 t 5310 t 5410

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert white : retention value: light retention insert yellow : retention value: medium

retention insert green : retention value: strong

Mounting Collar Silicone

2 Pieces per package

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

71T-Series

T-S

eri

es

Den

tsp

ly-F

riad

ent

Fr

ialit

/Xiv

The T-Series abutments are compatible withDentsply-Friadent Frialit/Xive® Implants

72 Y-Series

aButMENt SCrEW

titanium ti6aL4V

hex 1,0 mm

recommended torque: 25 Ncm

NEW

implant connection 3,5-7,0

article Number Y 61

LaB SCrEW

red-coated

NEW

implant connection 3,5-7,0

article Number Y 61 L

implant connection 3,5-7,0

Products indicated with ® are registered brand names of respective manufactures.

the Y-Series abutments are compatible with

Dentsply-Friadent ankylos® implants

Y-Series

73Y-Series

Y-S

eri

es

Den

tsp

ly-F

riad

ent

A

nky

los®

The Y-Series abutments are compatible withDentsply-Friadent Ankylos® Implants

medentiCAD®

SCaNBODY 2. GENEratiON

rOtatiNG

titan, special-coated

inkl. Screw

for titanium Base bars and bridges

for intra-oral scanning

sterilisable

NEW

implant connection 3,5-7,0

article Number Y 1400

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 3,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 0,65 1,15

implant connection 3,5-7,0 3,5-7,0

article Number Y 1500 Y 1700

titaNiuM BaSE FOr BarS aND BriDGES rOtatiNG

Wax uP hEiGht 5,5 MM

titanium Grade 5 CF

incl. abutment screw

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 0,65 1,15

implant connection 3,5-7,0 3,5-7,0

article Number Y 1600 Y 1800

medentiBASE®

MedentiBaSE aDhESiVE CaP FOr PaSSiVE-Fit

titanium adhesive Cap short Y 4800 incl. Bridge screwPlastic adhesive Casing short Y 4810 incl. Modelling screwtitanium adhesive base long Y 4820 incl. Bridge screwPlastic adhesive base long Y 4830 incl. Modelling screw

recommended torque: 15 Ncm

NEW

article Number Y 4800 Y 4810 Y 4820 Y 4830

MedentiBaSE Finisher connection geometry M 17 MedentiBaSE Finisher screw head M 18

Carbide

this is used to finish the fitting surfaces for the plastic cap Y 4710 after casting. the finishers are used in the processing holder prosthetic M 04.

NEW

article Number M 17 M 18

implant connection 3,5-7,0

74 Y-Series

medentiLOC®

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

NOVaLOC™ PrOCESSiNG PaCkaGEMatrix housing titanium/PEEk retention insert weiß : abzugsgewicht: light retention insert gelb : abzugsgewicht: medium

retention insert grün : abzugsgewicht: strong

Mounting collar Silicone

2 Stück pro Packung

incl. Montageeinsatz

Material Matrix housing

titanium PEEk

article Number 2010.601 2010.611

75Y-Series

Y-S

eri

es

Den

tsp

ly-F

riad

ent

A

nky

los®

The Y-Series abutments are compatible withDentsply-Friadent Ankylos® Implants

PLEASE NOTE: All OptilocTM abutments are available at the end of 2013.Find more details about OptiloctM abutments on page 82

OPtiLOCtM aButMENt

titanium Nitrit Coating

one-piece

implant connection 3,5-7 mm

recommended torque: 25 Ncm

NEW

Gingiva height (mm) 1 2 3 4 5

article Number Y 5000 Y 5100 Y 5200 Y 5300 Y 5400

OPtiLOC™ PrOCESSiNG PaCkaGE NEW

Matrix housing CoCr/PEEkretention insert weiß : abzugsgewicht: light retention insert gelb : abzugsgewicht: medium

retention insert grün : abzugsgewicht: strong

Mounting collar Silicone

2 Stück pro Packung

Material Matrix housing

CoCr PEEk

article Number 2012.501 2012.511

turNiNG iNStruMENt

FOr OPtiLOCtM aButMENt

Lab Screwdriver/ratchet

type short long

article Number M 11-9 M 10-9

GiNGiVa hEiGht MEaSuriNG tOOL aLtuStM

NEW

type Gingiva height measuring tool altustM

article Number 2013.901

76

tools

77Tools

To

ols

WOODEN tOOL BOx „MEDENtika“without prostetic tools

article Number MB 01

WOODEN tOOL BOx

„Manual insert long“

Wooden tool box offers space for the optional ratchet M 12 and further Manual inserter

Content: M 10-1, M 10-2,M 10-3, M 10-4, M 10-5

article Number MB 04-k

WOODEN tOOL BOx

„Manual insert short“

Wooden tool box offers space for the optional ratchet M 12 and further Manual inserter

Content:M 11-1, M 11-2,M 11-3, M 11-4, M 11-5

article Number MB 05-k

MaChiNiNG hOLDEr PrOSthEtiC DENtiStrY iN WOODEN tOOL BOx

Box incl. machining holder prosthetic dentistry and allen key

Content: M 04 and allen key

article Number MB 05

78

COMPartMENt BOx

without content

Polystyrene plastic

30 compartments

article Number MB 04

PrOSthEtiC traY

without prosthetic tools

sterilisable

Massive PPP milled

Stainless Steel sliding cover

laser cutted

custom equippedarticle Number M 13

Offers space for: torque ratchet M 12 and inserts for M 12, M 10-1, M 11-1, M 10-2, M 11-2, M 10-3, M 11-3, M 10-4, M 11-4, M 10-5 M 11-5, M 11-6

tOrquE ratChEt

with torque adjustment up to max. 40 Ncm

Stainless Steel hardened

type ratchet/handshaft

article Number M 12

MedentiBaSE SCrEW DriVEr/ratChEt

two-piece

Stainless Steel

article Number M 11-6

aDaPtEr FOr ratChEt M 12

handshaft to iSO-Shaft

article Number M 14

79Tools

To

ols

iNSErt FOr LaBOratOrY SCrEW-DriVEr aND ratChEt

Stainless steel hardened

iSO-long/short for ratchet M 01 hand-long/short for ratchet M 12

C-SeriesD-Seriesi-Seriesr-SeriesS-SeriesMedentiLOC straight

hex 0,05“ (1,26 mm)

type iSO-long iSO-short hand-long hand-short

article Number M 03-1 M 09-1 M 10-1 M 11-1

iNSErt FOr LaBOratOrY SCrEW-DriVEr aND ratChEt

Stainless steel hardened

iSO-long/short for ratchet M 01 hand-long/short for ratchet M 12

t-Seriesh-Series

hex 1,20 mm

type iSO-long iSO-short hand-long hand-short

article Number M 03-2 M 09-2 M 10-2 M 11-2

iNSErt FOr LaBOratOrY SCrEW-DriVEr aND ratChEt

Stainless steel hardened

iSO-long/short for ratchet M 01 hand-long/short for ratchet M 12

Y-Series

hex 1,00 mm

type iSO-long iSO-short hand-long hand-short

article Number M 03-3 M 09-3 M 10-3 M 11-3

iNSErt FOr LaBOratOrY SCrEW-DriVEr aND ratChEt

Stainless steel hardened

iSO-long/short for ratchet M 01 hand-long/short for ratchet M 12

N-SeriesL-SeriesB-Series

torx t6

type iSO-long iSO-short hand-long hand-short

article Number M 03-4 M 09-4 M 10-4 M 11-4

iNSErt FOr LaBOratOrY SCrEW-DriVEr aND ratChEt

Stainless steel hardened

iSO-long/short for ratchet M 01 hand-long/short for ratchet M 12

E-SeriesF-Seriesk-SeriesuG

type iSO-long iSO-short hand-long hand-short

article Number M 03-5 M 09-5 M 10-5 M 11-5

80

turNiNG iNStruMENt FOr MEDENtiLOC- aButMENt

StraiGht/aNGLED

iSO for ratchet M 01

hand for ratchet M 12

type MedentiLOC straight

MedentiLOC straight

MedentiLOC angled

MedentiLOC angled

article Number M 03-1 M 10-1 M 03-7 M 10-7

turNiNG iNStruMENt FOr NOVaLOCtM- aButMENt

hand for ratchet M 12

type short long

article Number M 11-8 M 10-8

turNiNG iNStruMENt FOr OPtiLOCtM- aButMENt

hand for ratchet M 12

type short long

article Number M 11-9 M 10-9

LaBOratOrY SCrEW DriVEr

for iSO-inserts

Stainless Steel

torque 10 Ncm

article Number M 03

MaChiNiNG hOLDEr PrOSthEtiC DENtiStrY

Stainless Steel massive

fits for all inserts of machining holder

article Number M 04

MedentiBaSE Finisher connection geometry MedentiBaSE Finisher connection geometry rN 4,8 MedentiBaSE Finisher screw head

hartmetallthis is used to finish the fitting surfaces for the plastic cap 4710 after casting.

the finishers are used in the processing holder prosthetic M 04. Finisher M 19 is used for plastic cap N 4710.

NEW

connection geometry

connection geometry

rN 4,8

screw head

article Number M 17 M 19 M 18

81Tools

To

ols

PiNS

For titanium base

anodized aluminium

8,00 Eur 8,00 Eur

fits for: C 1500 - C 1520h 800 - h 820h 1000 - h 1020h 1100 - h 1120h 1500 - h 1520k 800, k 1000k 1100, k 1500N 800, N 1000N 1100S 1030, S 1130S 1530t 800 - t 820t 1000 - t 1020t 1100 - t 1120t 1500 - t 1520

fits for: B 1000, B 1100B 1500D 1000, D 1010D 1100, D 1110D 1200, D 1210D 1300, D 1310D 1500, D 1510F 800, F 1000F 1100, F 1200F 1300, F 1500L 801, L 811L 1000, L 1010L 1100, L 1110L 1500, L 1510S 800, S 1000S 1100, S 1200S 1300, S 1500

article Number M 05-1 M 05-2

PiNS

For titanium base

anodized aluminium

fits for: S 820S 1020, S 1220S 1120, S 1320S 1520

fits for: E 800 - E 830E 1000 - E 1030E 1100 - E 1130E 1500 - E 1520F 810, F 1010F 1110, F 1210F 1310, F 1510i 800 - i 820i 1000 - i 1020i 1100 - i 1120i 1500 - i 1520k 810, k 1010k 1110, k 1510N 810, N 820N 1010, N 1020N 1110, N 1120N 1510, N 1520r 800 - r 820r 1000 - r 1020r 1100 - r 1120r 1500 - r 1520

article Number M 05-3 M 05-4

82

Optiloc™

For all those who want to stop searching for the optimal attachment system

or

simply dream of a small diameter Locator®.

83OptilocTM

Slimmer than Locator®, lower than ball attachments.

Optimal dimensions of the matrix housing allow the placement in narrow spaces.

the clever technology also allows a proper fixation of the denture on only 2 implants. the Optiloc™ matrix tolerates small movements of the denture without uncoupling from the abutment.

Well-known problems when fixing a matrix housing chair-side have been solved with Optiloc™.

the matrix has a clear defined position on the abut-ment which also reduces the risk of composite inte-gration into the housing.

1. Optimal dimensions

2. Optimal combination of Locator® and ball abutment

84

the unique design of the abutment facilitates the daily insertion of the denture and prevents the retention inserts from being damaged.

the abutment holds independently on the screw driver and can be safely transferred to the im-plant. improved material properties reduce the wear of abutments. available in various gingiva heights and compatible on a variety of implant systems.

the Optiloc™ matrix system is based on the es-tablished Novaloc™ technology.

Different retention forces fixate the denture and divergences can be corrected up to 40 degrees between two implants. the Optiloc™ system of-fers an optimal user-friendliness and longevity.

3. Optimal comfort for the patient

4. Optimal user-friendliness and wear resistance

5. Optimal matrix system

85OptilocTM

Picture Part no. Part description Specifications Amount per pack-

age

Preis EUR

2012.201 OptilocTM Equipment Box

Incl. 2 tools tool brown 2012.341 tool grey 2012.351 (without initial load)

1 pc.

2012.501OptilocTM Processing package CoCr

• CoCr matrix housing (1 pc)• retention insert white (1 pc)• retention insert yellow (1 pc)• retention insert green (1 pc)• Mounting collar, silicone (1 pc)

2 pcs.

2012.511OptilocTM Processing package PEEK

• PEEk matrix housing (1 pc)• retention insert white (1 pc)• retention insert yellow (1 pc)• retention insert green (1 pc)• Mounting collar, silicone (1 pc)

2 pcs.

2012.301OptilocTM Matrix housing CoCr

Matrix housing: CoCr 4 pcs.

2012.302OptilocTM Matrix housing PEEK

Matrix housing: PEEk 4 pcs.

2012.303OptilocTM Matrix housing elliptic, CoCr

Matrix housing: CoCr 4 pcs.

2012.304OptilocTM Matrix housing elliptic, PEEK

Matrix housing: PEEk 4 pcs.

special accessory

2012.305OptilocTM Matrix housing CoCr with attachment option

Matrix housing: CoCr 4 pcs.

special accessory

2012.310OptilocTM Retention insert red

PEEkRetention force:

extra-light

4 pcs.

2012.311OptilocTM Retention insert white

PEEkRetention force:

light 4 pcs.

2012.312OptilocTM Retention insert yellow

PEEkRetention force:

medium 4 pcs.

2012.313OptilocTM Retention insert green

PEEkRetention force:

strong 4 pcs.

2012.314OptilocTM Retention insert blue

PEEkRetention force:

extra-strong

4 pcs.

special accessory

2012.315OptilocTM Retention insert black

PEEkRetention force:

ultra-strong

4 pcs.

2012.321 OptilocTM Model analogue aluminium 4 pcs.

2012.322OptilocTM

Forming/fixing matrix PEEk 4 pcs.

2012.323 OptilocTM Processing spacer POM C 4 pcs.

2012.324OptilocTM

Mounting collar SiliconeSilicone 10 pcs.

2012.331OptilocTM Model analogue reposition aid + laboratory abutment driver blue

aluminium, Steel 1 pc.

2012.341OptilocTM Mounting and de-mounting tool for Retentions inserts (brown)

aluminium, Steel 1 pc.

2012.351OptilocTM

Matrix housing extractor (grey)

aluminium, Steel 1 pc.

86

Matrix system for MedentiLOC®

10 reasons why you choose Novaloc™

the Novaloc™ matrix system with its newly developed technology is a ready-made con-nective element to fix removable dentures to MedentiLOC® abutments.

Matrix housing in beige PEEk; the solution when there is very little space or when not using metal is a prerequisite.

1. Matrix hOuSiNG MaDE OF titaNiuM Or PEEk

2. StrESS-FrEE MOuNtiNG aND rEMOViNG OF rEtENtiON iNSErtS

1. Mount retention inserts 1. hold demounting tool vertically over the retention insert

2. insert into the matrix housing

2. Set up with slight pressure

3. Clearly audible “click” 3. remove vertically upwards

iNSErt rEMOVE

87NovalocTM

1. Mount model analogue

1. heat extraction head

Special design:No more hot finger!

1. use the stainless steel finish

2. insert model analogue

2. heat matrix housing briefly

2. insert at an angle into the bore of the mounting insert

absolutely safe handling

3. apply leverage to remove matrix housing

3. By tipping easily removed from the matrix housing

3. thE iNGENiOuS NOVaLOC™ MODEL aNaLOGuE rEPOSitiON aiD

4. thE CLEVEr DEMOuNtiNG tOOL FOr MOuNtiNG iNSErtS

5. thE uSEr-FriENDLY NOVaLOC™ EquiPMENt BOx

6. thE “5-SECONDS” Matrix hOuSiNG ExtraCtOr

• No caps in the inventory• Ensures overview and order• Ordering number legible in the cover• No separation when the cover is closed• three special instruments for all sorts of manipulations

88

9. PrOCESSiNG SPaCEr NOW With BLOCkiNG CharaCtEriStiCS

7. NOVaLOC™ ONLY rEquirES 4 rEPLaCEMENt MaLES

8. FOrMiNG/FixiNG Matrix FOr a SaFE aND aCCuratE POSitiONiNG iN thE MOuth.

Conventional damage to Nylon inserts commercially available until now

a 5° inclination for the shaping of a self-retaining box for matrix attachment

For additional mechanical blocking

retention forcelight

retention forcemedium

retention force strong

retention forceextra-strong

Easy to understand colour code according to retention force.

Multivalent can also be used as a fixing matrix for templates, bite registers and rails

NEW: Clearly smaller and more precise than those form-ing matrices commercially available until now

10. CLEarLY LESS WEar aND tEar aS WELL aS SErViCiNG ExPENSE at thE rEtENtiON iNSErtS • Novaloc™ retention inserts need no central retention element

(considerable advantage with regard to damage) • PEEk has better physical properties and is considerably more hygienic than Nylon

89NovalocTM

Picture Part no. Part description Specifications Amount per pack-

age

Preis EUR

2010.101 NovalocTM Equipment Box Incl. 3 tools (without load)

1 pc.

2010.601NovalocTM

Processing package Titanium

• titanium matrix housing incl. mounting insert (1 pc)

• retention insert white (1 pc)• retention insert yellow (1 pc)• retention insert green (1 pc)• Mounting collar, silicone (1 pc)

2 pcs.

2010.611NovalocTM

Processing package PEEK

• PEEk matrix housing incl. mounting insert (1 pc)

• retention insert white (1 pc)• retention insert yellow (1 pc)• retention insert green (1 pc)• Mounting collar, silicone (1 pc)

2 pcs.

2010.701NovalocTM Matrix housing Titanium (incl. black mounting insert)

Matrix housing: titaniumMounting insert: PEEk

4 pcs.

2010.702NovalocTM Matrix housing PEEK (incl. black mounting insert)

Matrix housing: PEEkMounting insert: PEEk

4 pcs.

special accessory

2010.703

NovalocTM Matrix housing Titanium with attachment option (incl. black mounting insert)

Matrix housing: titaniumMounting insert: PEEk

4 pcs.

special accessory

2010.710NovalocTM

Retention insert redPEEkRetention force:

extra-light

4 pcs.

2010.711NovalocTM

Retention insert whitePEEkRetention force:

light 4 pcs.

2010.712NovalocTM

Retention insert yellowPEEkRetention force:

medium 4 pcs.

2010.713NovalocTM

Retention insert greenPEEkRetention force:

strong 4 pcs.

2010.714NovalocTM

Retention insert bluePEEkRetention force:

extra-strong

4 pcs.

special accessory

2010.715NovalocTM

Retention insert blackPEEkRetention force:

ultra-strong

4 pcs.

2010.721 NovalocTM Model analogue aluminium 4 pcs.

2010.722NovalocTM Forming/fixing matrix

PEEk 4 pcs.

2010.723NovalocTM

Processing spacer whitePOM C 4 pcs.

2010.724NovalocTM

Mounting collar, SiliconeSilicone 10 pcs.

2010.725NovalocTM

Mounting insert, blackPEEk 4 pcs.

2010.731NovalocTM Demounting tool for mounting inserts + model analogue reposition aid (blue)

aluminium, Steel 1 pc.

2010.741NovalocTM Mounting and de-mounting tool for Retention inserts (brown)

aluminium, Steel 1 pc.

2010.751NovalocTM Matrix housing Extractor (grey)

aluminium, Steel 1 pc.

90

Altus™ GiNGiVa hEiGht MEaSuriNG tOOL

too high or low lying abutments finally belong to the past!

Locates the highest gingiva position

read the measurement results outside the oral cavity and choose the correct abutment height.

quick positioning without screwing

ACCURATE DETERMINATION OF ThE gINgIvA LEvELS WITh ALTUS™ BEFORE ChOOSINg AN ABUTMENT

RECORD ThE CORRECT hEIghT WITh EASE.

91AltusTM

Locates the highest gingiva position

quick positioning without screwing

Gingiva plate

the altus™ gingiva height measuring tool allows the precise measurement of the gingiva height above the implant for ac-curate determination and choice of the abutment height.

altus™ convinces with ease of use. the positioning onto the implant is done with ease. No time-consuming screwing into the implant.

its specially shaped gingiva plate locates the highest gingiva position in all situations around the implant.

altus™ guarantees longevity in use and can be sterilized easily in the autoclave.

altus™ has a guide for tweezers to even access the most dif-ficult positions in the mouth.

altus™ gingiva height measuring tool consists of a slider (PEEk) and a multifunctional scale part (titanium).

altus™ can be used on a variety of platforms (expandable on request).

92

gUARANTEE

MEDENtika not only offers a 30 year guarantee for the Medentika and MedentiCaD abutments made from titanium manufactured and supplied by MEDENtika, including the abutment screw, but additionally offers a guarantee on the implants of other manufacturers inserted with the abutment. immediate restorations are specifically excluded from this guarantee. the guarantee for the implant applies for example if the manufacturer of the implant inserted with the abut-ment restricts or refuses to offer its guarantee on this because the implant was combined with a MEDENtika or MedentiCaD abutment.

For further information on this, consult our guarantee terms which we hereby explicitly refer you to.

as at: February 2013

93

as at: January 2012

gUARANTEE CONDITIONS

From 1 January 2012 we provide a guarantee on our original Medentika and MedentiCaD abutments („our products“), and additionally a guarantee on implants of other manufacturers combined with our products as follows:

We guarantee the replacement of our products without additional costs if they reveal material or manufactur-ing defects or they do not comply with our quality standards.

We guarantee the reimbursement of proven material costs for a replacement implant if an implant of another manufacturer was combined with our products after its integration and the manufacturer of the implant there-fore refuses to provide its guarantee for the implant because it was combined with our products.

the guarantee period for our products is 30 (thirty) years from delivery. We provide a guarantee on implants of other manufacturers for the same period of time as the manufacturer also provides a guarantee, but for a maximum period of 30 years from delivery. No new guarantee or extension of the guarantee is linked with the guarantee performance.

Our Locator and MedentiLOC abutments and Novaloc and SFiBar components are excluded from this guaran-tee. a guarantee period of 3 (three) applies for these products. all the die plates and their inserts are subject to natural wear and tear and are excluded from the guarantee.

No guarantee shall be granted:

• in the case of immediate restorations • For damage of other products or the implants due to external impacts such as accidents or comparable

events and incorrect treatment • For failure of the implants of other manufacturers, such as material or manufacturing faults• For failure of our products or the implants in the case of contraindications such as alcoholism, diabetes or

drug addiction• For further claims and consequential damages such as laboratory costs or the costs of clinical and/or dental

treatment.

this voluntary guarantee is supplementary to the guarantee rights defined by law and the product liability and does not effect these. in addition, our General terms and Conditions of Sale shall apply.

the assignment of rights from this guarantee requires our consent.

MEDENtika guarantee for our products and the implants of other manufacturers

1 aPPLiCatiON all our deliveries or services (hereinafter, „Service“) and offers - including

those in the future - are effected solely based on our General terms and Conditions of Business (hereinafter, „General terms“). these are a com-ponent of all contracts with us; they are also valid even if no particular reference is made to them. From our website, the General terms can be downloaded or printed as a file. Our General terms apply in relation to companies (§§ 14, 310 of the German Civil Code (Bürgerliches Gesetzbu-ch, „BGB“)). Our General terms have exclusive application. the customer‘s general terms and conditions of business do not apply, even if we have not separately objected to them. these do not become the content of a contract even if an order is accepted or carried out without any reserva-tion.

2 CONCLuSiON OF CONtraCtS unless otherwise expressly declared, our offers are non-binding. For the

scope and the subject matter of the Service, the delivery note is control-ling. if the delivery note includes changes to the customer‘s order, it is deemed to be agreed if the customer receives the Service without any res-ervation and does not object to the Service in writing within a reasonable period.

any reference to technical standards serves the purpose of describing the Service, and is not a warranty for a particular condition. information or il-lustrations (e.g. weights, measures, utility values and technical data) are only approximate, to the extent that the usability for the contractual pur-pose does not require exact conformity. Obvious mistakes and any error in printing, writing, computing or calculation do not result in any obliga-tion and cannot establish any claim.

3 PriCES, PaYMENt Our current list prices apply in every case. unless otherwise agreed, pay-ments are due 10 days after invoicing without any deduction. the timeli-ness of any payment is determined by the crediting of our account. the customer is entitled to a right of retention or the right to engage in a set-off only to the extent that its counterclaims are undisputed or have been established as legally effective.

4 DELiVErY the delivery period amounts to 1 to 2 business days (Mo. - Fr., excluding

holidays). the delivery period is deemed to be adhered to if the shipping company collects the package for shipment within this period. We assume no liability for any delay on the part of the shipping company. We shall insure our Service or the transport at the previous instruction and the ex-pense of the customer. any shipment is effected without any guarantee of the cheapest method, at the expense and risk of the customer.

5 rEtENtiON OF titLE For any Service, we reserve the right of ownership until the receipt of all

payments arising from the business relationship. in the event of a resale, the customer hereby assigns to us as security all claims arising from such resale against the custo-mer and/or its insurance policy. the customer is authorised to collect receivables in our name; this authorisation is revoca-ble.

6 riGhtS rELatiNG tO DEFECtS immediately after receipt, the customer must carefully examine the Ser-

vice that has been received. We must be immediately notified in writing of any defect („Defect Notice“). if there are any transport damages, the shipment company is to be provided documentation. in all other respects, § 377 of the German Commercial Code (handelsgesetzbuch, „hGB“) ap-plies. if there is no notification, the Service is deemed to be acceptable and in accordance with the order, unless this concerns a defect that was not recognisable upon the examination. Such defects must be notified im-mediately after their discovery. this does not apply to any fraudulent con-cealment of a defect. any resale or use of a Service subject to objection is deemed to be its approval, and the contract is deemed to be fulfilled; in this respect, any claim based on the defect is barred.

By entering into negotiations regarding Defect Notices, we do not waive the objection that such Defect Notices are not timely, unfounded or oth-erwise insufficient. any measure to reduce damages is not deemed to be the recognition of a defect.

Deviations from the agreed quality and scope caused by the materials, along with changes to the Service in the course of technical progress, in the design, the embodiment, the dimensions, the weight or the colour are permissible within the framework of tolerances customary in the industry, to the extent that they do not limit usability for the contractually planned use, there is no warranty and, upon an objective assessment, all of the facts are reasonable to the customer.

the customer is liable for unjustified Defect Notices, if the cause of the defect is in its area of responsibility and he was (at a minimum) negligent in not recognising this. We charge for expenses for which we are not re-sponsible within the framework of the liability for defects in accordance with our current list prices.

to the extent not attributable to us, we assume no warranty upon any un-suitable or improper use and/or improvement, any incorrect assembling and/or start-up by the customer or a third party, non-observance of pro-cessing guidelines or operating instructions, natural wear and tear, any incorrect or careless treatment or storage, maintenance or servicing that is not done on an orderly basis, any unsuitable operating material, any chemical, electro-chemical, electrical or environmentally caused influence. the same applies to changes to the Service undertaken without our con-sent, or the exchange of components or use of expendable materials that do not correspond to the original specifications, unless the defect is not based on such. the right to a price reduction is barred, unless the defect that is present is not merely immaterial, the defect was fraudulently con-cealed or the defect concerns a warranty for a particular condition.

in accordance with § 478 of the BGB, claims to recourse on the part of the customer exist only to that extent that the customer has not made an agreement with the consumer going beyond the statutory claims for defects. the suspension of the limitation period under § 479 of the BGB applies only if the customer has verifiably provided a guarantee to its customers.

7 LiaBiLitY in accordance with the statutory provisions, we are liable without any lim-

itation for personal injuries, under product liability law, upon the assump-tion of a warranty for a particular condition, for the malicious conceal-ment of defects, for damages that are based on intentional acts and to the extent that damages are covered by our operating liability insurance policy. Moreover, upon a grossly negligent violation of an obligation, we are liable according to the statutory provisions; solely upon a grossly neg-ligent violation of an obligation not substantial to the contract is our li-ability limited to foreseeable damages typical for contracts.

For slight negligence, we are liable upon the violation of material con-tractual obligations; such liability is hereby limited to foreseeable dam-ages typical for contracts, the emergence of which could be expected. in all other respects, our liability is barred. Material contractual obliga-tions are those whose fulfilment the proper carrying out of the contract is absolutely necessary and whose adherence the customer regularly re-lies and may rely.

Liability exclusions and limitations also apply for the benefit of our gov-erning bodies, statutory representatives, employees and other vicarious agents. the customer is obligated to maintain its own insurance policies in a scope customary in its industry and for its structure (particularly includ-ing business interruption insurance). any contributory negligence on the part of the customer must be taken into account.

8 LiaBiLitY LiMitatiON For any limitation of liability to foreseeable damages typical for contracts,

liability is limited to 50,000.00 euros per loss event; however, for all dam-ages within one calendar year, this is limited to the maximum of double this amount. We are also liable beyond the extent to which our insurer steps in to provide compensation for damages and furnishes payment.

any warranty claims on the part of the customer are time-barred in 12 months after the transfer/delivery of the Service. the statutory periods apply to deliberate or malicious content, to personal injuries or to claims under product liability law.

9 rEturN unopened, undamaged Services without signs of usage may be returned

within 4 weeks from the delivery date. a copy of the invoice must be at-tached. the customer shall bear the costs of the original shipment and the return. any shipment by mail subject to fees will not be accepted.

10 Data PrOtECtiON the customer provides its consent for our saving of its data (communica-

tion data, responsible employees, type and scope of its orders, etc.) until the contract is concluded. We may also use the data to inform customer of our products and Service, if these are typically used in connection with the products and Service that the customer acquired from us.

11 CONCLuDiNG PrOViSiONS any change or supplement to a contract that is not based on an individual

agreement requires written form (including by fax). this also applies to any waiver of the requirement of written form. if any provision of these terms and conditions is or becomes ineffective, this does not otherwise af-fect the validity of the terms and conditions. German law applies. For all disputes arising from the contract, the place of performance and area of jurisdiction of natural and legal entities that, upon the conclusion of the contract, are acting in the exercise of their commercial or independent professional activity (companies) is our registered office. however, we are entitled to bring suit against the customer at the court of the customer‘s residence.

gENERAL TERMS AND CONDITIONS OF BUSINESS OF MEDENTIKA gMBh

as at: January 2012

Medentika Gmbh

hammweg 8–1076549 hügelsheim

tel.: +49 (0)7229-69912-0Fax: +49 (0)7229-69912-20

E-Mail: [email protected]

Der WeberFink Gbr

Graphic Design Studio

www.weberfink.de

Design by:

Editor:

imprint

Product catalogue News 2013 Status July 2013: [PM 003_001]Medentika reserves the right to make modifications to the products through technical and dimensional improvements without prior notice; errors and printing errors excepted.

Edition:

Precision and Functionality:implant Components made in Germany

Medentika Gmbhhammweg 8–1076549 hügelsheim

tel.: +49 (0)72 29-69912-0Fax: +49 (0)72 29-69912-20

E-Mail: [email protected]