Upload
trinhkhanh
View
238
Download
0
Embed Size (px)
Citation preview
| 1
FOR PROFESSIONALS
Product Catalog
A BONE ANCHORED FACIAL PROSTHETIC SOLUTION
ContentsSterile products Vistafix 3 System 4
Sterile products Prior generation Vistafix 6
Prosthetic and lab components 8
Reusable instruments 12
Osscora surgical set and accessories 13
Compatibility of reusable instruments 14
Training equipment and accessories 15
Instrument and component guide Vistafix 3 System 16
Instrument and component guide Prior generation Vistafix 17
Retention component guide 18
Index 19
NOTE : • Imagesinthisguidearenottoscale. • Notallproductsareavailableinallmarkets.Productavailabilityissubjecttoregulatory approvalintherespectivemarkets.
The Cochlear™ Vistafix® 3 System consists of:
• CochlearVistafixVXI300Implant(Vistafix3Implant)• CochlearVistafixVXA300Abutment(Vistafix3Abutment)
The prior generation Vistafix System consists of:
• CochlearVistafixSTFixtures(flangeless)• Standardabutments
| 54 |
Sterile productsAllimplants,abutmentsandcoverscrewsaremade oftitanium.Allsterileproductsareforsingleuseonly.
Cochlear Vistafix 3 ImplantsUsedforVistafixone-stageortwo-stagesurgery.
Cochlear Vistafix 3 AbutmentsTheVXA300Abutmentsareonlycompatible withVXI300Implants.
NOTE:TheVXA300Abutmentscrewsshouldbetightenedto25Ncm.
Cochlear Vistafix 3 Healing AbutmentThe healing abutment is used during healing and allowsthecliniciantoselectingafinalabutmentheightafterhealinghasoccurred,oncethefinaltissuethicknessisknown.Themarkingsonthehealing abutment can be used to indicate the thicknessofthesofttissue.Thehealingabutmentismountedontheimplant.
NOTE:TheVXA300Healingabutmentshouldbetightenedto25Ncm.
92994 VXA300 Abutment3.5mm 92995 VXA300Abutment4.5mm
92996 VXA300Abutment6mm 92997 VXA300Abutment7.5mm
93100 VXI300Implant 3mm,Ø4.5mm
93101VXI300Implant 4mm,Ø4.5mm
92998VXA300Healingabutment
Cover screw
NOTE:ThecoverscrewconicalisonlycompatiblewithVXI300Implants.
DrillsStainlesssteel.
NOTE:Theguidedrillhasaremovablespacerfordrillingtodifferentdepths.
WARNINg: Theguidedrillsandwideningdrillsfeaturedhereareonlycompatiblewiththe Vistafix3System,andCANNOTbeusedwith priorgenerationVistafixImplantsandFixtures.
Biopsy punch
NOTE:Thebiopsypunchisonlysoldinpacksof10.
Healing capThe healing cap is used to hold the dressing inplaceduringhealing.
93102Coverscrewconical forVistafixVXI300Implant
92139 Guide drill 3+4mm,Ø2.3mm
92141 Widening drill withcountersink4mm, Ø4.1mm
92140 Widening drill withcountersink3mm, Ø4.1mm
90802HealingcapØ14mm
90940BiopsypunchØ4mm
90801 HealingcapØ6.5mm
Vistafix 3 System
| 76 |
Flangeless implantsImplantshaveamachinedtitanium surfaceandhexagonalconnection.
Healing abutment and healing caps
Cover screw
NOTE:CoverscrewisforpriorgenerationVistafixonly.
Instruments – reusable
90478 Connection to handpiece 90941 Abutmentclamp for counter-torque
90438 FixtureST 3mm,Ø3.75mm
90436 Healing abutment Unigrip 7 mm
90801 Healingcap Ø6.5mm
Standard abutments
NOTE: Standard abutments are only compatiblewithpriorgeneration Vistafix Implants
Drills
Instruments for limited space – reusable
90415 Guide drill 3+4mm,Ø1.8mm
90238 Fixturemount Unigrip short
90456 Screwdriver for hexagon 17 mm
90416 Drill countersink3mm, Ø3.3mm
90380 Drill Machine screwdriverUnigrip20mm
90459 Screwdriver Unigrip20mm
90417 Drill countersink4mm, Ø3.3mm
90453 Screwdriverfor internalhexagon20mm
90620 Coverscrew spacewithinternalhexagon
90780 Standard abutment 3 mm
90778 Standard abutment 4 mm
90776 Standard abutment5.5mm
90774 Standard abutment 7 mm
90440 FixtureST 4mm,Ø3.75mm
90802Healingcap Ø14mm
Sterile productsPrior generation Vistafix
| 98 |
Prosthetic and lab componentsBarconstructioncomponents.
90446 Gold bar Ø2x50mm
Prosthetic components for Cochlear Vistafix 3 SystemDuringtheprostheticwork,thegoldbarissoldered to the gold cylinders and the clips incorporatedintheacrylicoftheprosthesis.
NOTE: The gold cylinder 4 mm can be ground down1mmtoa3mmgoldcylinder.Thegoldscrewshouldbetightenedto10Ncm.
NOTE:Forfullretentionforce,theclipattachmentshouldbeactivatedbycarefullycompressingthetwolamellae.
90338GoldscrewUnigrip for gold cylinder
Prosthetic lab components compatible with both Cochlear Vistafix 3 and prior generation Vistafix
90796 Guidepin20mm
93184 Gold cylinder 4 mm forVistafixVXA300
93192 Impression coping squared for VistafixVXA300
93185 Abutment replica for VistafixVXA300
90842 Clip attachmentØ2mm
90448 Gold bar Ø2x100mm
Prior generation Vistafix prosthetic components
90374 Abutment replica
90772 Gold cylinder 4 mm
90379 Impression coping squared
90794 Guidepin10mm
| 1110 |
DeSCrIPTION PrODuCT ImAge
DeSCrIPTION PArT
NumBer
HeIgHT (mm)
DIAmeTer (mm)
reTeNTION
FOrCe (N)
AurICulAr mAgNeT Magnet for auricular magnacaps
MLL2-OR-S 2.7 5.5 19.4
PrOSTHeSIS mAgNeTS Micro magnetMini magnetMidi magnetMaxi magnet
M0-SM1-SM2-SM3-S
1.993.23.23.9
4.54.55.55.5
4.26.510.511.5
PrOSTHeSIS mAgNeTS (Lip design)
Micro lip magnetMini lip magnetMidi lip magnetMaxi lip magnet
ML0-SML 1-SML2-SML3-S
1.993.23.23.9
4.54.55.55.5
4.26.510.511.5
PrOSTHeSIS mAgNeTS (Long lip design)
Maxi long lip magnet MLL3-S 3.9 5.5 11.5
AurICulAr mAgNACAP for Vistafix 3 System
Auricularmaximagnacap for Vistafix 3 System
VF-MC2-OR-S 2.7 5.26
mAgNACAPS for Vistafix 3 System
Mini magnacap for Vistafix 3 System
Maxi magnacap for Vistafix 3 System
VF-MC1-S
VF-MC2-S
2.1
2.1
4.4
5.1
AurICulAr mAgNACAP for prior generation Vistafix
Auricularmaximagnacap for prior generation Vistafix
BMC2-OR-S 2.7 5.5*
mAgNACAPS for prior generation Vistafix
Mini magnacap for prior generation Vistafix Maxi magnacap for prior generation Vistafix
B-MC1-S
B-MC2-S
2.1
2.1
4.4
5.1
mAgNABuTmeNTS for prior generation Vistafix
Mini magnabutment Maxi magnabutments for prior generation Vistafix only
E-MA1-SE-MA2-S
3.63.6
4.45.1
Magnet components (manufactured by Technovent Ltd).
*Atfittingsurface.
DeSCrIPTION PrODuCT ImAge
DeSCrIPTION PArT NumBer
HeIgHT (mm) DIAmeTer (mm)
lAB COmPONeNTS Mini hand capfit toolMaxi hand capfit toolMini latch capfit toolMaxi latch capfit tool
CF1CF2CF3CF4
Transfer magnet MT1MT2
3.23.2
4.55.5
Lab analog capfor prior generation Vistafix
B-LAC1B-LAC2
2.12.1
4.45.1
Lab analog capfor Vistafix 3 System • Mini magnacap •Maximagnacap and auricular magnacap
V-LAC1V-LAC2
2.12.1
4.45.1
Lab analog abutment LAA1LAA2
2.53.5
4.45.1
Locator ringsfor prior generation Vistafix
LR1LR2
LR-LL2
| 1312 |
reusable instruments
90381 Machine screwdriverUnigrip25 mm
90397 Machine screwdriverabutment
90459ScrewdriverUnigrip20mm
90944 Raspatorium
92142 Implant inserter
Osscora surgical set and accessoriesOsscora surgical setAlltheOsscorasurgicalsetsaredeliveredwith thefollowingarticles:• Motorwith3.5mcableincludingmotorprotective
cover,lockingpins(2pcs)andclips(10pcs)
• Osscoracontra-anglehandpieceincluding sprayclips(2pcs)andnozzlecleaner
• Irrigationtubingset(6pcs)
• FootcontrolS-N1
• Irrigationstand
• Powerable
91053 Osscora surgical set 115 V
AccessoriesThefollowingcomponentcanbeordered as an accessory to the Osscora surgical set:
91102 Sterilizationcassette
Spare partsThefollowingarticlescanbeorderedasspare parts for the Osscora surgical set:
91050 Osscorahandpiece20:1 91054 Osscora motor withcable3.5m
04032600 Motor protectivecover
91116 Drill indicator for WS-75 and Osscora
90943 Dissector
90469 ScrewdriverUnigrip 95 mm
92143 MultiwrenchwithISOadapter
92347 ISO adapter forMultiwrench.Spare part for Multi wrench. For compatibility with ISO instruments such as implant inserter.
92290 Square adapter forMultiwrench.For compatibility withfixture mount on implants with hexagonal connection.
92353 ISO adapter forsurgicalwrench.For compatibility with ISOinstruments such as implant inserter.
90408Screwdriverfor internal hexagon
93183 Counter torquewrenchforVistafixVXA300
90139 Surgical organizer
90146 Instrument organizer
Allinstrumentsareorderedindividually.Forinstrumentcompatibility,seepage14.Forcleaningandsterilizationguidelines please see the Vistafix Treatment and SurgeryGuide.
NOTE: The instruments in this page are used for the Vistafix3System.Inadditiontothis,thereareinstrumentsusedforthepriorgenerationimplantsystem,seepriorgenerationVistafix,page14.
Wrench adapters
| 1514 |
Training equipment and accessories
Training equipment
Accessories
91040 Abutmentcleaningbrush
91153 ½Skullmodel withsofttissue
90643 ¼Skullmodel, plastic temporal bone
90644 ½Skullmodel,plastic temporal bone
92150 Dummy implant 4 mm
93385 Dummy VistafixVXA300Abutment6mm
Compatibility of reusable instruments
91050Osscorahandpiece20:1
92347 ISO adapter for Multiwrench
92353 ISO adapter for surgicalwrench
90478Connection to handpiece
90381Machinescrew-driverUnigrip25mm
92142 Implant inserter
VXI300Implant
92143Multiwrench
90338GoldscrewUnigrip for gold cylinder
Standard abutments withhexagonal
connection
Prior generation Vistafix series
VXA300Healingabutment
VXA300Abutment
NOTE: Theabovechartexplainscompatibilitybetweenbothnewandpriorgenerationsofinstruments.
90762Surgicalwrench
90397Machinescrewdriverabutment
90941Abutmentclamp
93183 Vistafix counter torquewrench
92290SquareadapterforMultiwrench
STfixturewith fixture mount
Prior generation Vistafix series
| 1716 |
PATIENT COMPONENTS
VX
I300
Impl
ants
Cove
r scr
ewV
XA
300
Abu
tmen
tsH
ealin
g ca
p an
d ab
utm
ent
ASSOCIATED INSTRUMENTS
90802 Healingcap Ø14mm
92143 Multiwrenchwith
ISO adapter
Insertion
Instrument and component guide
93100 3 mm
93101 4 mm
92142 Implant inserter
93102 CoverscrewconicalforVistafixVXI300Implant
90459 ScrewdriverUnigrip
20mm
90469 Screwdriver
Unigrip 95 mm
92994 3.5mm
92995 4.5mm
92996 6 mm
92997 7.5mm
90397 Machinescrewdriver
abutment
93183 Counter torque wrenchfor
VistafixVXA300
90397 Machine screwdriverabutment
92998 VXA300Healing
abutment
93183 Counter torque wrenchfor
VistafixVXA300
90469 Screwdriver
Unigrip 95 mm
92143 Multiwrenchwith
ISO adapter
90459 Screwdriver
Unigrip20mm
92143 Multiwrenchwith
ISO adapter
LABORATORY COMPONENTS
gol
d cy
linde
r an
d go
ld s
crew
Impr
essi
on c
opin
gs
and
guid
e pi
ns
ASSOCIATED INSTRUMENTS
90794 Guide pin 10mm
90796 Guide pin 20mm
PATIENT COMPONENTS ASSOCIATED INSTRUMENTS
90469 Screwdriver
Unigrip 95 mm
90469 Screwdriver
Unigrip 95 mm
90469 Screwdriver
Unigrip 95 mm
90338 Goldscrew
Unigrip
93184 Gold cylinder
4 mm for Vistafix VXA300Abutment
90459 ScrewdriverUnigrip
20mm
90381 Machinescrew-driver
Unigrip 25 mm
93192 Impression
coping squared for
VistafixVXA300
93185 Abutmentreplica for
VistafixVXA300
92143 Multiwrenchwith
ISO adapter
LABORATORY COMPONENTS
gol
d cy
linde
r an
d go
ld s
crew
Impr
essi
on c
opin
gs
and
guid
e pi
ns
ASSOCIATED INSTRUMENTS
90794 Guide pin 10mm
90796 Guide pin 20mm
PATIENT COMPONENTS ASSOCIATED INSTRUMENTS
90381 Machinescrew-driver
Unigrip 25 mm
90469 Screwdriver
Unigrip 95 mm
90338 Goldscrew
Unigrip
90772 Gold cylinder
90459 ScrewdriverUnigrip
20mm
90379 Impression
coping squared
90374 Abutment
replica
Instrument and component guidePrior generation Vistafix
PATIENT COMPONENTS
Prio
r gen
erat
ion
V
ista
fix im
plan
tsPr
ior g
ener
atio
n
Vis
tafix
Abu
tmen
tsH
ealin
g ca
p an
d
abut
men
t
ASSOCIATED INSTRUMENTS
FOR TIgHTENINgFOR TIgHTENINg
FOR HEALINg CAPFOR HEALINg CAP
FOR COUNTER TORqUEFOR COUNTER TORqUE
90802 Healingcap Ø14mm
92143 Multiwrenchwith
ISO adapter
FOR HEALINg ABUTmENT
90438 3mm,
Ø3.75mm
90440 4mm,
Ø3.75mm
90397 Machinescrewdriver
abutment
90941 Abutmentclamp
90436 Prior generation
Healingabutment
90469 Screwdriver
Unigrip 95 mm
92143 Multiwrenchwith
ISO adapter
90459 Screwdriver
Unigrip20mm
ImPOrTANT: Only the listedguide drills are compatible with the prior generation Vistafix implants. The guide drill and countersink drills CANNOT be used with the Vistafix 3 System implants.
90417 Countersink 4mm,
Ø3.3mm
90416 Countersink 3mm,
Ø3.3mm
90478 Connection to
handpiece
Cove
r scr
ew
90620 Coverscrewspacewith
internal hexaon
90453 Screwdriver
for internal hexagon
90780 3 mm
90778 4 mm
90776 5.5mm
90774 7 mm
90941 Abutmentclamp
90415 3+4mm, Ø1.8mm
Vistafix 3 System
FOR INSERTIONImPOrTANT: Only the listedguide drills are compatible with the Vistafix 3 Systemimplants. The guide drill andwidening drills CANNOT beused with the prior generation Vistafix implants.
92139 Guide drill 3+4mm, Ø2.3mm
92140 Widening drill withcountersink 3mm,Ø4.1mm
92141 Widening drill withcountersink 4mm,Ø4.5mm
FOR HEALINg ABUTmENT
90381 Machinescrew-driver
Unigrip 25 mm
| 1918 |
retention component guidePART NAME PART NUMBER PAGE
¼Skullmodel,plastictemporalbone 90643 15
½Skullmodelwithsofttissue 91153 15
½Skullmodel,plastictemporalbone 90644 15
Abutmentclamp 90941 7
Abutmentreplica 90374 8
AbutmentreplicaforVistafixVXA300 93185 8
Auricularmagnet MLL2-OR-S 10
Auricularmaximagnacap,forpriorgenerationVistafix BMC2-OR-S 10
Auricularmaximagnacap,forVistafix3System VF-MC2-OR-S 10
BiopsypunchØ4mm 90940 5
Cleaningbrush 91040 15
Connectiontohandpiece 90478 14
CountertorquewrenchforVistafixVXA300 93183 12
CoverscrewconicalforVistafixVXI300Implant 93102 5
Coverscrewspacewithinternalhexagon 90620 6
Dissector 90943 12
Drillcountersink3mm 90416 6
Drillcountersink4mm 90417 6
Drill indicator for WS-75 and Osscora 91116 12
DummyImplant4mm 92150 15
DummyVistafix3Abutment 93385 15
FixturemountUnigripshort 90238 7
FixtureST3mm,flangeless 90438 6
FixtureST4mm,flangeless 90440 6
GoldbarØ2x100mm 90448 9
GoldbarØ2x50mm 90446 9
Goldcylinder4mmforpriorgenerationVistafix 90772 8
Goldcylinder4mmforVistafixVXA300 93184 8
GoldscrewUnigripforgoldcylinder 90338 9
Guidedrill3+4mmØ1.8mmforpriorgenerationVistafix 90415 6
Guidedrill3+4mmØ2.3mm 92139 5
Guidepin10mm 90794 9
Guidepin20mm 90796 9
HealingabutmentUnigrip7mm 90436 7
HealingcapØ14mm 90802 7
HealingcapØ6.5mm 90801 7
Implant inserter 92142 12
Impressioncopingsquared 90379 8
ImpressioncopingsquaredforVistafixVXA300 93192 8
Instrumentorganizer 90146 12
ISOadapterforMultiwrench 92347 12
ISOadapterforsurgicalwrench 92353 12
Labanalogabutment LAA1 11
Labanalogabutment LAA2 11
LabanalogcapforpriorgenerationVistafix B-LAC1 11
LabanalogcapforpriorgenerationVistafix B-LAC2 11
LabanalogmaximagnacapforVistafix3System V-LAC2 11
LabanalogminimagnacapforVistafix3System V-LAC1 11
Locator rings for prior generation Vistafix LR1 11
Locator rings for prior generation Vistafix LR2 11
Locator rings for prior generation Vistafix LR-LL2 11
Machinescrewdriverabutment 90397 12
MachinescrewdriverUnigrip20mm 90380 12
MachinescrewdriverUnigrip25mm 90381 12
Maxihandcapfittool CF2 11
Maxilatchcapfittool CF4 11
Maxilipmagnet ML3-S 10
Maxilonglipmagnet MLL3-S 10
MaximagnabutmentsforpriorgenerationVistafixonly E-MA2-S 10
MaximagnacapforpriorgenerationVistafix B-MC2-S 10
IndexPART NAME PART NUMBER PAGE
MaximagnacapforVistafix3System VF-MC2-S 10
Maximagnet M3-S 10
Microlipmagnet ML0-S 10
Micromagnet M0-S 10
Midilipmagnet ML2-S 10
Midimagnet M2-S 10
Minihandcapfittool CF1 11
Minilatchcapfittool CF3 11
Minilipmagnet ML1-S 10
MinimagnabutmentforpriorgenerationVistafixonly E-MA1-S 10
MinimagnacapforpriorgenerationVistafix B-MC1-S 10
MinimagnacapforVistafix3System VF-MC1-S 10
Minimagnet M1-S 10
Motorprotectivecover 4032600 13
MultiwrenchwithISOadapter 92143 12
Osscorahandpiece20:1 91050 13
Osscoramotorwithcable3.5m 91054 13
Osscorasurgicalset115V(US,Canada) 91053 13
Raspatorium 90944 12
Screwdriverforhexagon 90408 12
Screwdriverforhexagon17mm 90456 7
Screwdriverforinternalhexagon20mm 90453 7
ScrewdriverUnigrip20mm 90459 7
ScrewdriverUnigrip95mm 90469 12
SquareadapterforMultiwrench 92290 12
Standardabutment3mm 90780 6
Standardabutment4mm 90778 6
Standardabutment5.5mm 90776 6
Standardabutment7mm 90774 6
Sterilizationcassette 91102 13
Surgicalorganizer 90139 8
Transfer magnet MT1 11
Transfer magnet MT2 11
VXA300Abutment4.5mm 92995 4
VXA300Abutment6mm 92996 4
VXA300Abutment7.5mm 92997 4
VXA300Abutment3.5mm 92994 4
VXA300Healingabutment 92998 4
VXI300Implant3mm 93100 4
VXI300Implant4mm 93101 4
Wideningdrillwithcountersink3mm 92140 5
Wideningdrillwithcountersink4mm 92141 5
*Seewww.technovent.com
93101 4 mm
93100 3 mm
92994 3.5mm
92995 4.5mm
92996 6 mm
92997 7.5mm
93184 Gold cylinder
4 mm for VistafixVXA300
BAR RETENTION
90338 Goldscrew
Unigrip
90842 Clip attachment
Ø2mm
90446 or 90448
Gold bar Ø2x50mm Ø2x100mm
MAGNET RETENTION*
VF-mC1-S VF-mC2-S
Magnacaps for Vistafix 3 System*
mll2-Or-S Auricularmagnet
VF-mC2-Or-S Auricular
magnacap for Vistafix 3 System
m0-Sm3-S ml0-Sml3-S
mll3-S Prosthesis magnets*
MAGNET RETENTION*
mll2-Or-S Auricularmagnet
B-mC2-S Auricular
magnacap for prior generation Vistafix
mm0-S m0-Sm3-S
ml0-Sml3-S mll3-S
Prosthesis magnets*
mC1-S mC2-S
Magnacap
e-mA1-S e-mA2-S
Magnabutment
90772 Gold cylinder
for prior generation Vistafix
90440 4 mm
90438 3 mm
STANDARD ABUTmENTS FOR PRIOR gENERATION VISTAFIx ImPLANTSVxA300 ABUTmENTS
PRIOR gENERATION VISTAFIx ImPLANTSVxI300 ImPLANTS
90780 3mm
90778 4mm
90776 5.5mm
90774 7 mm
Prior generation VistafixUniversalVistafix 3 System
VFX002 ISS1 JUN12
Cochlear Americas13059EastPeakviewAvenueCentennial,CO80111USA
Telephone: 13037909010Support: 18004833123WebChat: www.CochlearAmericas.com
Cochlear Canada Inc2500-120AdelaideStreetWestToronto,ONM5H1T1Canada
Telephone: 14169725082Fax: 14169725083
©2012 Cochlear Limited. All rights reserved. Trademarks and registered trademarks are the property of Cochlear Limited or Cochlear Bone Anchored Solutions. The names of actual companies and products mentioned herein may be the trademarks of their respective owners.
www.CochlearAmericas.com
Asyourpatient’spartner,Cochlearbelievesitisimportanttoconveynotonlythebenefits,butalsothepotentialrisksassociatedwithaCochlearVistafixprocedure.
Vistafixiscontraindicatedinpatientswithinadequatebonequalityorquantitytoprovidestabilityandsupportfortheimplant,orinpatientswhowillbeunabletomaintainandcleantheskinaroundtheabutment.IntheU.S.andCanada,useoftheimplantedfixture isalsocontraindicatedinchildrenunderagefiveyears.
Allsurgicalproceduresincludeanelementofrisk,anditisimpossibletoguaranteesuccess.Thedevicemayfailtoosseointegrateforanumberofreasons,includingphysiologicalandsurgicalissuesaswellastraumaticimpacttotheimplantsite.Onrareoccasionstheskinaroundtheabutmentmaybecomeinflamedfromamildinfectionortheskinmaygrowbacktowardsitsoriginalthickness.ForcompleteinformationregardingtherisksandbenefitsofaVistafixprocedure,pleaserefertotheInstructionsforusefortheVistafiximplantavailableatwww.CochlearAmericas.com/VistafixIndications