    MAGNETIC FLOW METER ELMAG 60H

    SALIENT FEATURES

    DESCRIPTION

    DIMENSIONAL DETAILS

    1

    Line Size Flange Diameter

    ‘D’

    Diameter of Raised Face

    ‘R’

    Diameter of Bolt Hole

    Circle ‘DBC’

    Diameter of Bolt Hole

    No. of

    Holes

    Flange Distance

    ‘FD’

    Flow Range(m3/hr) at 0.03m/s to 6m/s

    Inch NB Minimum Maximum ½” 15 88.9 34.9 60.3 15.9 4 200 0.019 3.817 3/4” 20 98.4 42.9 69.8 15.9 4 200 0.033 6.785 1 ” 25 107.9 50.8 79.4 15.9 4 200 0.053 10.602

    1 ½ ” 40 127.0 73 98.4 15.9 4 200 0.135 27.143 2” 50 152.4 92.1 120.6 19.0 4 200 0.212 42.4115

    2 ½ ” 65 177.8 104.8 139.7 19.0 4 200 0.358 71.675 3 ” 80 190.5 127.0 152.4 19.0 4 200 0.542 108.573 4” 100 228.5 157.2 190.5 19.0 8 250 0.848 169.646 5 ” 125 254.0 185.7 215.9 22.2 8 250 1.325 265.071 6” 150 279.4 215.9 241.3 22.2 8 300 1.9085 381.703 8” 200 342.9 269.9 298.4 22.2 8 350 3.3929 678.584 10” 250 406.4 323.8 361.9 25.4 12 450 5.3014 1060.28 12” 300 482.6 381.0 431.8 25.4 12 500 7.6340 1526.81 14” 350 533.4 469.9 476.2 28.6 12 500 10.3908 2078.16 16” 400 596.9 533.4 539.7 28.6 16 600 13.5716 2714.33 18” 450 635.0 584.2 577.8 31.7 16 600 17.1766 3435.33 20” 500 698.5 692.1 635.0 31.7 20 600 21.2057 4241.15 24” 600 812.8 692.1 749.3 34.9 20 600 30.5362 6107.25

    Ø DBC

    Ø Bolt Hole

    Lining

    R

    D

    Fig. Side View

    E L E C T RON E T

    E L MAG -6 0 H

    FD

    Fig. Front View

    Note : For Line size above 600NB consult factory. Typical mounting dimensions for reference. Standard factory calibration for 0.2 to 2 m/s velocity. Flow meter should be selected with the help of

    Nomograph recommended full scale velocity. Flow indication of 5 digit max. up to 99999

    Full bore type Suitable for conductive liquids 2 wire system with HART communication Material option depending upon process data Empty pipe indication Local Indication through Graphics LCD Maintenance free Simple & cost effective construction Inbuilt Data Logger

    The ELMAG-60H is a micro-controller based 2 wire full bore type electromagnetic flow transmitters specially used for various industrial applications. These flow transmitters accurately measure the flow rate of conductive liquids & slurries in closed pipes. Due to its simple & rigid design, the flow transmitter is an obstruction- less & maintenance-free instrument in place of conventional mechanical flow measuring device. The use of ‘Pulsed DC’ technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 mA DC inearly proportional to volumetric flow, The instrument is based on Faraday’s law of electromagnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity & corresponding electrical output is provided with respect to easuring voltage.

  • ELECTRONET Powered by

    ORDERING INFORMATION

    2

    MAGNETIC FLOW METER ELMAG 60H TECHNICAL SPECIFICATIONS

    Media Conductivity Viscosity Line Size Excitation Type of Output Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction

    Power Supply Power Consumption Response Time Electronics Transmitter Enclosure Process Connections Mounting Operating Conditions

    : Liquids (Conductive) : > 5 µs/cm : 200 cp max : 15 NB to 600 NB : Pulsed DC coil : 4 to 20mA DC, 2 wire HART : COG Graphic LCD display - 5 digit for Flow Rate & 8 digit for Totalizer Flow : As per requirement (Factory Calibrated for std. 2m/s velocity) : +/- 0.5% M.V.(For 20 to 100% flow) : +/- 0.5% of M.V. : +/- 0.2% of M.V. : +/- 0.1% per °C : 85° C max for Rubber Lining & 220°C for PTFE Lining : 10 kg/cm² max (higher on request) : Lining - Neoprene Rubber / Hard Rubber / EPDM / PFA / PTFE

    Flange - MS / CS / SS316 Electrode - SS 316L/ Hastalloy C / Platinum / Tantalum Coil Housing - MS / SS 304 / SS316

    : 24 V DC : < 40mW :

  • ELECTRONET Powered by

    ● Suitable for conductive liquid ● Maintenance free ● Insertion Type ● Local Indication through LCD ● Simple & cost effective construction ● Unit conversion facility ● Material option depending upon process data ● Universal Power Supply 90 to 260V AC Optional 24V DC ● Communication port (Optional)

    SALIENT FEATURES

    DESCRIPTION

    The ELMAG-100 is a micro-controller based full bore type electromagnetic flow meters specially used for various industrial applications. These flow meters accurately measures the flow rate of conductive liquid & slurries in closed pipes. Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device.The use of ‘Pulsed DC’ technology offers highest ability & better measuring accuracy in the form of electrical signal 4 - 20mA DC linearly proportional to volumetric flow. The instrument is based on Faraday’s law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid following through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range.

    TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output

    : : : : : :

    Display : Calibration Range : Accuracy : Linearity : Repeatability : Process Temperature : Process Pressure : Material of construction :

    Power Supply :

    Power Consumption : Response Time : Temperature Coefcient : Process Connections : Mounting : Operating Conditions : Transmitter Enclosure :

    Liquids (Conductive) > 5 µs/cm 200 cp max 200 NB to 2000 NB Pulsed DC 1) 4 to 20 mA DC 2) Pulse 16 x 2 LCD - 4 digit for Flow Rate & 8 digit for Totalised Flow As per requirement (Factory Calibrated up to 4NB) +/- 2% of F. S. (for 20 to 100% ow) +/- 0.5% of F. S. +/- 1% of F. S. 85 ºC max. 10 kg/cm2max Electrode - SS 316L Retractable Assembly - MS / SS 304 Wetted Parts - SS 316 Option 1: 24 V DC Option 2: 90 - 250 V AC, 50 Hz < 10 VA < 1 Sec +/- 0.01% per ºC ASA 150, 2” Flanged, as per table B 16.5 Insertion type Temperature 0 to 55 ºC / Humidity 5 to 95% non condensing Die Cast Aluminium IP 68

    OPTIONAL Communication Port :

    Remote Electronics :

    RS 485 supporting MODBUS RTU Protocol GSM connectivity Weather-proof, IP-65, wall mounted

    INSERTION TYPE ELECTROMAGNETIC FLOW METER ELMAG-100

    3

  • ELECTRONET Powered by

    DIMENSIONAL DETAILS

    1000mm

    120 mm

    200 mm

    90 mm

    FLOW INLET

    CMRI CERTIFIED DIE CAST ALUMINIUM FLAMEPROOF HOUSING

    5 mm GASKET NEOPRENE

    100m

    m

    26.5 mm

    2” SS FLANGE ASA 150 B-16.5

    19 mm

    19 mm

    2” SS FLANGE ASA 150 B-16.5

    19mm

    47mm

    M20 x 1.5,DOUBLE COMPRESSION CABLE ENTRY

    49 mm

    1&1/2” Ball Valve 290mm

    2” SS FLANGE ASA 150 B-16.5

    15 mm

    120 mm Adjustable

    26.5 mm

    LINE SIZE 200NB to 2000NB FLOW OUTLET

    PP ELMAG-100

    ELECTROMAGNETIC FLOW METER

    ELMAG-200E

    E L E C T R O N ET

    Line Size/6

    Note : • Typical mounting dimensions for reference • Standard factory calibration for 0 to 2m/Sec velocity

    Line Size (mm)

    Flow min

    (m/3hr)

    Flow normal (m/3hr)

    Flow max

    (m/3hr)

    Flow (MLD)

    200 5.66 113.10 565.50 2.714 250 8.84 176.71 883.55 4.241 300 12.72 254.47 1272.35 6.107 350 17.32 346.36 1731.80 8.313 400 22.62 452.39 2261.95 10.857 500 35.34 706.86 3534.30 16.965 600 50.89 1017.88 5089.40 24.429 700 69.27 1385.44 6927.20 33.250 800 90.48 1809.56 9047.80 43.429 900 114.51 2290.22 11451.10 54.965

    1000 141.37 2827.43 14137.15 67.858 1200 203.58 4071.50 20357.50 97.716 1400 277.09 5541.76 27708.80 133.002 1600 361.91 7238.22 36191.10 173.717 1800 458.04 9160.88 45804.40 219.861 2000 565.49 11309.72 56548.60 271.433

    *Due to our continuous product revisions, Design, Speci› cations and Model Number are subject to change without notice. *Accuracy de› ned at lab conditions. Note : GSM output is without SIM card & SCADA viewing software.

    ORDERING INFORMATION 04 All

    03 4-20mA + HART

    09 None 03 25 mtr.

    200 mm to 2000 mm

    R Remote 02 SS304 02 Pulse + 4-20mA 02 230V AC 03 GSM 02 10 mtr. 09 None 02 SS L Local 01 Aluminium 01 4-20 mA 01 24V DC 02 RS 485 01 5 mtr. 01 Data logger 01 MS

    SERIES Line Size Electronics Electronics Enclosure

    Output Power Supply

    Communi- cation Port

    Remote Cable Length

    Data Logging

    Retractable Sensor Assembly

    ELMAG-100 400 mm L / R E 01 F 01 G 02 H 02 I 02 J 01 K 02

    INSERTION TYPE ELECTROMAGNETIC FLOW METER ELMAG-100

    4

  • ELECTRONET Powered by

    ELECTROMAGNETIC FLOW METER ELMAG 200

    ● Suitable for conductive liquids ● Maintenance free ● Full bore type ● Local Indication through LCD ● Simple & cost effective construction ● Empty pipe indication ● Material option depending upon process data ● Universal Power Supply 90 to 260V AC Optional 24V DC ● Communication port (Optional) ● HART Communication

    SALIENT FEATURES

    DESCRIPTION

    The ELMAG-200 is a micro-controller based full bore type electromagnetic flow meters specially used for various

    industrial applications. These flow meters accurately measures the flow rate of conductive liquid & slurries in closed pipes.

    Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of conventional

    mechanical flow measuring device. The use of ‘ Pulsed DC’ technology offers highest ability & better measuring accuracy in

    the form of electrical signal 4 - 20mA DC linearly proportional to volumetric flow. The instrument is based on Faraday’s law of

    electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid following through this

    magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with

    respect to measuring flow range.

    250 mm

    OD

    P P

    ELEMLMAAGG--220000MH

    ELEECLETCRTORMOAMGAGNNEETTIICC FFLLOOWWMMETEETRER

    ELECTRONET

    H

    W FD

    ELECTRONET MODEL : SR. NO :

    Meter Size

    OD (mm)

    W (mm)

    H (mm)

    FD (mm)

    Flow Range (m³ /hr) Min Normal Max

    15 NB 88.9 100 180 200 0.03 1.2723 6.4

    20 NB 98.4 100 180 200 0.11 2.2619 11

    25 NB 107.9 100 180 200 0.18 3.5341 18

    32 NB 117.5 100 210 200 0.29 5.7906 29

    40 NB 127.0 100 210 200 0.45 9.05 45

    50 NB 152.4 100 210 200 0.71 14.14 71

    65 NB 177.8 100 220 200 1.19 23.892 119

    80 NB 190.5 100 240 200 1.81 36.19 181

    100 NB 228.5 150 274 250 2.83 56.55 283

    125 NB 254.0 175 300 250 4.42 88.35 442

    150 NB 279.4 175 330 300 6.36 127.23 636

    200 NB 342.9 175 390 350 11.3 226.18 1130

    250 NB 406.4 244 440 450 17.66 353.41 1766

    300 NB 482.6 250 520 500 25.43 508.91 2543

    350 NB 533.4 250 520 550 34.62 692.68 3462

    400 NB 596.9 250 520 600 45.22 904.72 4522

    450 NB 635.0 623 632 698 57.23 1145.04 5723

    500 NB 698.5 623 686 768 70.65 1413.63 7065

    600 NB 812.8 818 772 918 101.74 2035.63 10174

    DIMENSIONAL DETAILS

    OD : Flange Diameter H : Coil Housing Height

    W : Coil Housing width FD : Flange to Flange distance

    5

  • ELECTRONET Powered by

    TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output

    : : : : : :

    : : : : :

    Display Engineering Unit Calibration Range Accuracy Linearity Repeatability

    Process Temperature : Process Pressure : Material of construction :

    Power Supply :

    Temperature Coefcient :

    Power Consumption : Isolation : Response Time : Transmitter Enclosure : Process Connections : Mounting : Operating Conditions :

    Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 600 NB Pulsed DC 1) 4 to 20 mA DC, Isolated, HART 2) Pulse 16 x 2 LCD - 4 digit for Flow Rate & 8 digit for Totalised Flow User Programmable (m³ /hr by default) As per requirement (Factory Calibrated for std. 2m/s velocity) +/- 0.5% of F. S. (for 20 to 100% ow) +/- 0.5% of F. S. +/- 0.2% of F. S. +/- 0.05% per °C 85° C max for Rubber Lining & 120°C for PTFE Lining 10 kg/cm² max (higher on request) Lining - Rubber (5mm +/-1mm thick) / PTFE (Teon) (3mm +/-1mm thick) Flange - CS / MS / SS Electrode - SS 316L / Hastalloy C / Platinum Coil Housing - MS / SS 304 Option 1 : 24 V DC Option 2 : 90 - 260 V AC, 50 Hz < 10 VA 1.4 KV between Input, Output & Power Supply < 1 Sec Die cast Aluminium IP 66, ow tube IP 68 ASA 150 anged, as per table B 16.5 In-Line Horizontal (Vertical on request) Temperature 0 to 55°C / Humidity 5 to 95% non condensing

    Electronics

    Communication Port :

    : Remote Electronics

    Note :- For process conditions other than above please consult factory. OPTIONAL

    1) RS 485 supporting MODBUS RTU Protocol 2) GSM Communication 3) 4-20mA with HART

    ORDERING INFORMATION

    SERIES Line Size Electronics Lining Material

    Flange Coil Housing

    Electrode Electronics Material Enclosure

    Output Power Supply

    5 mtr.

    09 None 03 25 mtr.

    02 230V AC 02 GSM 02 10 mtr.

    4-20mA + HART 4-20mA + Pulse

    03

    02 SS304 02

    MS 01 SS 316L 01 Aluminium 01 4-20 mA 01 24V DC 01 RS 485 01 01 CS / MS 01

    02 SS304

    03 SS316 08 Other R Remote 02 Rubber L

    Local 01 PTFE 15 mm to 600 mm

    ELMAG-200 65 mm L / R A 02 B 01 C 01 D 01 E 01 F 01

    Communi- cation Port

    G 02 H 01

    Remote Cable Length

    I 02

    Data logging J 02

    *Due to our continuous product revisions, Design, Speci‹cations and Model Number are subject to change without notice. *Accuracy de‹ned at lab conditions. Note : GSM output is without SIM card & SCADA viewing software.

    Consult Factory

    04 All

    02 None 01 Datalogger

    08 Other

    03 SS316 03 Platinum

    02 SS 304 02 Hyst C

    ELECTROMAGNETIC FLOW METER ELMAG 200

    6

  • ELECTRONET Powered by

    BATTERY POWERED ELECTROMAGNETIC FLOW METER ELMAG-600

    Full bore type Suitable for conductive liquid Battery Operated Data Logging facility for 5 Years Local Indication through Graphics LCD Communication port (Optional) Empty pipe indication(Optional) Maintenance free Simple & cost effective construction Inbuilt Data Logger

    SALIENT FEATURES

    DESCRIPTION

    The ELMAG-600, is a battery-powered Electromagnetic flow meters are ideal when connecting to a power is difficult or expensive. When no mains power is available, the battery powered ELMAG-600 gives the flexibility to install a reliable flow meter, virtually anywhere, without distorting accuracy & performance. ELMAG-600 is provided with 2 years continuous battery operation. The flow meter is extremely easy to use, simple to install & requires no regular maintenance. The product is engineered for various industrial as well as domestic applications such as Municipal & Industrial Water applications, Cooling tower, Water treatment, etc. The graphic display provides indication for flow rate & totalized flow with key selection. The display auto shuts off after 10 minutes, which saves the battery life. The display can be turned ON by pressing the 'enter' key.

    TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction

    Power Supply Low Bat indication Battery Life Response Time Transmitter Enclosure Process Connections Mounting Operating Conditions Data Logging

    : Liquids (Conductive) : > 5 µs/cm : 200 cp max : 15 NB to 600 NB : Pulsed DC : COG Graphic LCD display- 5 digit for Flow Rate & 8 digit for Totalizer Flow : As per requirement (Factory Calibrated ) : +/- 0.5% of M.V. (for 20 to 100% flow) : +/- 0.5% of M.V. : +/- 0.2% of M.V. : +/- 0.05% per °C : 85° C max for Rubber Lining & 220°C for PTFE Lining : 10 kg/cm² max (higher on request) : Lining - Neoprene Rubber / Hard Rubber / EPDM / PFA / PTFE

    Flange - MS /CS / S316 Electrode - SS 316L/ Hastalloy C / Platinum / Tantalum

    Coil Housing - MS / SS 316 : Inbuilt Battery 3.6 V, 19 Ah ( 2 nos) : Provided : 2 to 10 years depending on sampling time. :

  • ELECTRONET Powered by

    DIMENSIONAL DETAILS

    Ø DBC

    Ø Bolt Hole

    Lining

    R

    FD

    Fig. Front View

    D

    Fig. Side View

    E L MAG 6 0 0

    Note : For Line size above 600NB consult factory. Typical mounting dimensions for reference. Standard factory calibration for 0.2 to 2 m/s velocity. Flow meter should be selected with the help of

    Nomograph recommended full scale velocity. Flow indication of 5 digit max. up to 99999

    0 1 5

    0.2% 0.1%

    0.0%

    1.0% 0.9%

    0.8%

    0.7%

    0.6%

    0.5%

    0.4%

    0.3%

    Mea

    surin

    g er

    ror (

    % M

    .V)

    2 3 4 Flow Velocity

    6 m/s

    DIMENSIONAL DETAILS OF FLANGE(AS PER ASA150 # B-16.5): Flow Nomograph Line Size Flange

    Diameter ‘D’

    Diameter of Raised Face

    ‘R’

    Diameter of Bolt Hole

    Circle ‘DBC’

    Diameter of Bolt Hole

    No. of

    Holes

    Flange Distance

    ‘FD’

    Flow Range(m3/hr) at 0.03m/s to 6m/s

    Inch NB Minimum Maximum ½” 15 88.9 34.9 60.3 15.9 4 200 0.019 3.817 3/4” 20 98.4 42.9 69.8 15.9 4 200 0.033 6.785 1 ” 25 107.9 50.8 79.4 15.9 4 200 0.053 10.602

    1 ½ ” 40 127.0 73 98.4 15.9 4 200 0.135 27.143 2” 50 152.4 92.1 120.6 19.0 4 200 0.212 42.4115

    2 ½ ” 65 177.8 104.8 139.7 19.0 4 200 0.358 71.675 3 ” 80 190.5 127.0 152.4 19.0 4 200 0.542 108.573 4” 100 228.5 157.2 190.5 19.0 8 250 0.848 169.646 5 ” 125 254.0 185.7 215.9 22.2 8 250 1.325 265.071 6” 150 279.4 215.9 241.3 22.2 8 300 1.9085 381.703 8” 200 342.9 269.9 298.4 22.2 8 350 3.3929 678.584 10” 250 406.4 323.8 361.9 25.4 12 450 5.3014 1060.28 12” 300 482.6 381.0 431.8 25.4 12 500 7.6340 1526.81 14” 350 533.4 469.9 476.2 28.6 12 500 10.3908 2078.16 16” 400 596.9 533.4 539.7 28.6 16 600 13.5716 2714.33 18” 450 635.0 584.2 577.8 31.7 16 600 17.1766 3435.33 20” 500 698.5 692.1 635.0 31.7 20 600 21.2057 4241.15 24” 600 812.8 692.1 749.3 34.9 20 600 30.5362 6107.25

    ORDERING INFORMATION

    * Accuracy defined at lab conditions.

    * Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice.

    * GSM output is without SIM card & SCADA viewing software. * For better accuracy consult factory.

    08 Other

    05 PTFE

    04 PFA 04 Tantalum

    03 EPDM 03 Platinum 03 Pulse

    02 Remote 02 SS 304 02 Hard Rubber

    02 SS 316 08 Other 02 SS 316 02 Hyst. C 02 GSM 02 10mtr

    15NB To 600NB

    01 Local 01 Aluminum 01 Neoprene Rubber

    01 MS /CS 01 ASA 150 01 MS 01 SS 316L 01 RS232 01 5mtr

    Series Line Size Electronics Electronic Enclosure

    Lining Material

    Flange Material

    Flange Rating

    Coil Housing

    Electrode Material

    Comm. Output

    Remote Cable Length

    ELMAG 600 A 150NB B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01

    BATTERY POWERED ELECTROMAGNETIC FLOW METER ELMAG-600

    8

  • ELECTRONET Powered by

    ELECTRONIC WATER METER ELMAG-600W SALIENT FEATURES

    DESCRIPTION The ELMAG-600W, battery-powered Electromagnetic water meters, are ideal when connecting to a power is difficult or expensive. When no mains power is available, the battery powered ELMAG-600W gives the flexibility to install a reliable flow meter, virtually anywhere, without distorting accuracy & performance. ELMAG-600W is provided with 2 years’ continuous battery operation. The water meter is extremely easy to use, simple to install & requires no regular maintenance. The product is engineered for various industrial as well as domestic applications such as Municipal & Industrial Water applications, Cooling tower, Water treatment, etc. The graphic display provides indication for flow rate & totalized flow with key selection. The display auto shuts off after 10 minutes, which saves the battery life. The display can be turned ON by pressing the 'enter' key. IT’S AN ELECTRONIC WATER METER.

    Electronic replacement to mechanical water meter Battery Powered Real time data Reliable connectivity Durability Accurate measurement Zero maintenance Tampering protection Low pressure loss Simple installation Simple & cost effective construction

    TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction Power Supply Low Bat indication Battery Life Response Time Transmitter Enclosure Process Connections Operating Conditions Data Logging

    : Water : > 5 µs/cm : 200 cp max : 15 NB to 40 NB : Pulsed DC : COG Graphical LCD display- 4 digit for Flow Rate & 6 digit for Totalizer Flow : As per requirement (Factory Calibrated) : +/- 1% of M.V. : +/- 1% of M.V. : +/- 0.5% of M.V. : +/- 0.05% per °C : 65 ºC max : 5 kg/cm² max : Electrode - SS 316L : Inbuilt Battery 3.6 V, 19 Ah : Provided : 2 to 10 years depending on sampling time. :

  • ELECTRONET Powered by

    H

    D

    L

    Meter Size

    L (mm)

    D (mm)

    H (mm)

    Flow Range (m³ /hr)

    Min Normal Max

    15 NB 88.9 100 180 0.03 1.2723 6.4

    20 NB 98.4 100 180 0.11 2.2619 11

    25 NB 107.9 100 180 0.18 3.5341 18

    32 NB 117.5 100 210 0.29 5.7906 29

    40 NB 127.0 100 210 0.45 9.05 45

    D : Diameter H : Height L : Length

    Note : ● Typical mounting dimensions for reference ● Standard factory calibration for 0.2 to 2 m/s

    velocity ● Max. flow range in LPH/LPM is upto 9999

    DIMENSIONAL DETAILS

    ELECTRONIC WATER METER ELMAG-600W

    SERIES

    ELMAG-600W

    * Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. * For GSM communication, SIM card & SCADA viewing software will be in customers scope. * Accuracy defined at lab conditions. * For better accuracy consult factory.

    05 40NB

    04 32NB

    03 25NB 03 Pulse (Open Collector)

    02 20NB 02 AMR-GSM

    01 15NB 01 RS232

    Line Size Communication Output

    A 01 B 01

    ORDERING INFORMATION

    10

  • ELECTRONET Powered by

    TWO WIRE ELECTROMAGNETIC FLOW METER ELMAG-600H SALIENT FEATURES Full bore type Suitable for conductive liquids 2 wire system with HART communication Material option depending upon process data Empty pipe indication Local Indication through Graphics LCD Maintenance free Simple & cost effective construction Inbuilt Data Logger

    DESCRIPTION

    The ELMAG-60H is a micro-controller based 2 wire full bore type electromagnetic flow transmitters specially used for various industrial applications. These flow transmitters accurately measure the flow rate of conductive liquids & slurries in closed pipes. Due to its simple & rigid design, the flow transmitter is an obstruction- less & maintenance-free instrument in place of conventional mechanical flow measuring device. The use of ‘Pulsed DC’ technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 mA DC inearly proportional to volumetric flow, The instrument is based on Faraday’s law of electromagnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity & corresponding electrical output is provided with respect to easuring voltage.

    TECHNICAL SPECIFICATIONS Media Conductivity Viscosity Line Size Excitation Type of Output Display Calibration Range Accuracy Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of construction

    Power Supply Power Consumption Response Time Electronics Transmitter Enclosure Process Connections Mounting Operating Conditions

    : Liquids (Conductive) : > 5 µs/cm : 200 cp max : 15 NB to 600 NB : Pulsed DC coil : 4 to 20mA DC, 2 wire HART : COG Graphic LCD display - 5 digit for Flow Rate & 8 digit for Totalizer Flow : As per requirement (Factory Calibrated for std. 2m/s velocity) : +/- 0.5% M.V.(For 20 to 100% flow) : +/- 0.5% of M.V. : +/- 0.2% of M.V. : +/- 0.1% per °C : 85° C max for Rubber Lining & 220°C for PTFE Lining : 10 kg/cm² max (higher on request) : Lining - Neoprene Rubber / Hard Rubber / EPDM / PFA / PTFE

    Flange - MS / CS / SS316 Electrode - SS 316L/ Hastalloy C / Platinum / Tantalum Coil Housing - MS / SS 304 / SS316

    : 24 V DC : < 40mW :

  • ELECTRONET Powered by

    DIMENSIONAL DETAILS

    Ø DBC

    Ø Bolt Hole

    Lining

    R

    D

    Fig. Side View

    E L E C T RON E T

    E L MAG -6 0 H

    Note : For Line size above 600NB consult factory. Typical mounting dimensions for reference. Standard factory calibration for 0.2 to 2 m/s velocity. Flow meter should be selected with the help of

    Nomograph recommended full scale velocity. Flow indication of 5 digit max. up to 99999

    0.2% 0.1%

    0.0%

    0 1

    1.0% 0.9%

    0.8%

    0.7%

    0.6%

    0.5%

    0.4%

    0.3%

    Mea

    surin

    g er

    ror (

    % M

    .V)

    2 3 4 5 6 m/s Flow Velocity

    FD

    Fig. Front View

    DIMENSIONAL DETAILS OF FLANGE(AS PER ASA150 # B-16.5): Flow Nomograph Line Size Flange

    Diameter ‘D’

    Diameter of Raised Face

    ‘R’

    Diameter of Bolt Hole

    Circle ‘DBC’

    Diameter of Bolt Hole

    No. of

    Holes

    Flange Distance

    ‘FD’

    Flow Range(m3/hr) at 0.03m/s to 6m/s

    Inch NB Minimum Maximum ½” 15 88.9 34.9 60.3 15.9 4 200 0.019 3.817 3/4” 20 98.4 42.9 69.8 15.9 4 200 0.033 6.785 1 ” 25 107.9 50.8 79.4 15.9 4 200 0.053 10.602

    1 ½ ” 40 127.0 73 98.4 15.9 4 200 0.135 27.143 2” 50 152.4 92.1 120.6 19.0 4 200 0.212 42.4115

    2 ½ ” 65 177.8 104.8 139.7 19.0 4 200 0.358 71.675 3 ” 80 190.5 127.0 152.4 19.0 4 200 0.542 108.573 4” 100 228.5 157.2 190.5 19.0 8 250 0.848 169.646 5 ” 125 254.0 185.7 215.9 22.2 8 250 1.325 265.071 6” 150 279.4 215.9 241.3 22.2 8 300 1.9085 381.703 8” 200 342.9 269.9 298.4 22.2 8 350 3.3929 678.584 10” 250 406.4 323.8 361.9 25.4 12 450 5.3014 1060.28 12” 300 482.6 381.0 431.8 25.4 12 500 7.6340 1526.81 14” 350 533.4 469.9 476.2 28.6 12 500 10.3908 2078.16 16” 400 596.9 533.4 539.7 28.6 16 600 13.5716 2714.33 18” 450 635.0 584.2 577.8 31.7 16 600 17.1766 3435.33 20” 500 698.5 692.1 635.0 31.7 20 600 21.2057 4241.15 24” 600 812.8 692.1 749.3 34.9 20 600 30.5362 6107.25

    TWO WIRE ELECTROMAGNETIC FLOW METER ELMAG-600H

    ORDERING INFORMATION

    * Accuracy defined at lab conditions.

    *Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. *GSM output is without SIM card & SCADA viewing software. * For better accuracy consult factory.

    08 Other

    05 PTFE

    04 PFA 04 Tantalum

    03 EPDM 03 Platinum

    02 Remote 02 SS 304 02 Hard Rubber

    02 SS 316 08 Other 02 SS 316 02 Hyst. C 02 4-20mA + HART

    09 10mtr

    15NB To 600NB

    01 Local 01 Aluminum 01 Neoprene Rubber

    01 MS / CS 01 ASA 150 01 MS 01 SS 316L 01 4-20mA 01 5mtr

    Series Line Size Electronics Electronic Enclosure

    Lining Material

    Flange Material

    Flange Rating

    Coil Housing

    Electrode Material

    Output Remote Cable Length

    ELMAG 60H A 15NB B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01

    12

  • ELECTRONET Powered by

    ● Suitable for conductive liquid ● Maintenance free ● Full bore type ● Simple & cost effective construction ● Power Supply 24V DC ● Supported by “ Flow view” software

    SALIENT FEATURES

    ELECTROMAGNETIC FLOW METER ELMAG-800

    DESCRIPTION

    The ELMAG-800 is a micro-controller based full bore type electromagnetic flow meters specially used for various industrial domestic applications. These flow meters accurately measures the flow rate of conductive liquid & slurries in closed pipes. Due to simple & rigid design, the flow meter is an obstruction less & maintenance free instrument in place of conventional mechanical flow measuring device. The use of ‘ Pulsed DC’ technology offers highest ability & better measuring accuracy in the form of electrical signal in the form of RS 485 communication linearly proportional to volumetric flow. The instrument is based on Faraday’s law of electro-magnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range.

    TECHNICAL SPECIFICATIONS

    Media Conductivity Viscosity Line Size Excitation Type of Output Calibration Range Accuracy Linearity Repeatability Temperature Coefficient : Process Temperature : Process Pressure : Material of construction :

    Power Supply Power Consumption Isolation Response Time Transmitter Enclosure Process Connections Mounting Operating Conditions Communication

    : : : : : : : : :

    Liquids (Conductive) > 5 µs/cm 200 cp max 15 NB to 200 NB Pulsed DC RS 485 As per requirement (Factory Calibrated for std. 2m/s velocity) +/- 0.5% of F. S.(for 20 to 100% flow) +/- 0.5% of F. S. +/- 0.2% of F. S. +/- 0.05% per °C 85° C max for Rubber Lining 10 kg/cm² max (higher on request) Lining - Rubber (5mm +/-1mm thick) Flange - CS / MS Electrode - SS 316L Coil Housing - MS 24 V DC < 10 VA 1.4 KV between Input, Output & Power Supply < 1 Sec Die cast Aluminium IP-66, flow tube IP-68 ASA 150 flanged, as per table B 16.5 (other on request) In-Line (Horizontal OR Vertical) Temperature 0 to 55 C / Humidity 5 to 95% non condensing RS 485

    : : : : : : : : :

    13

  • ELECTRONET Powered by

    DIMENSIONAL DETAILS FLOW NOMOGRAPH

    H

    W FD

    MO D E L :

    ELECTRONET S R . N O :

    Meter Size

    OD (mm)

    W (mm)

    H (mm)

    FD (mm)

    Flow Range (m³ /hr)

    Min Normal Max

    15 NB 88.9 100 180 200 0.03 1.2723 6.4

    20 NB 98.4 100 180 200 0.11 2.2619 11

    25 NB 107.9 100 180 200 0.18 3.5341 18

    32 NB 117.5 100 210 200 0.29 5.7906 29

    40 NB 127.0 100 210 200 0.45 9.05 45

    50 NB 152.4 100 210 200 0.71 14.14 71

    65 NB 177.8 100 220 200 1.19 23.892 119

    80 NB 190.5 100 240 200 1.81 36.19 181

    100 NB 228.5 150 274 250 2.83 56.55 283

    125 NB 254.0 175 300 250 4.42 88.35 442

    150 NB 279.4 175 330 300 6.36 127.23 636

    200 NB 342.9 175 390 350 11.3 226.18 1130

    ELECTRONET ELMAG 800

    OD : Flange Diameter H : Coil Housing Height

    W : Coil Housing width FD : Flange to Flange distance Note :

    ▪Typical mounting dimensions for reference ▪Standard factory calibration for 0 to 2m/Sec velocity ▪ Max. Flow range in LPH / LPM is upto 9999

    ▪Flow meter should be selected with the help of Nomograph recommended full scale velocity

    ELECTROMAGNETIC FLOW METER ELMAG-800

    *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions.

    15 mm to 200 mm

    SERIES Line Size

    ELMAG-800 65 mm

    ORDERING INFORMATION

    14

  • ELECTRONET Powered by

    ORIFICE FLOW METER

    SALIENT FEATURES

    DESCRIPTION

    15

    ● Orifice Design as per BS EN ISO 5167 ● Range of Orifice types 1) Concentric Square Edge 2) Quarter Circle 3) Segmental 4) Eccentric

    The Orifice plate is the most common differential pressure flow primary element. It is based on proven technology has no moving parts and is suitable for high temperature and pressure applications. Orifice plates are recommended for clean liquids, gases and low velocity steam flows. Flow measurement using Orifice plates requires the accurate location of up stream and downstream pressure tappings. Various types of orifice carrier assemblies are available to suit a wide range of applications

    TECHNICAL SPECIFICATIONS

    Service Line Size Type

    Materials

    Orice Assembly

    : Liquid, Gas and Vapor Application : ½” to 20” : 1) Concentric Square Edge 2) Quarter Circle 3) Segmental 4) Eccentric

    : 1) Orifice plate with ANSI B16.36 Flange 2) Integral Orifice. 3) Carrier ring type

    : SS316 Std.(Others on Request)

    TYPES OF ORIFICE

    4. Eccentric: Suitable for measurement of dirty fluids and 2 phase flow preferred to segmental pipelines of diameters less than 350 mm.

    1. Square Edge : For general applications in clean fluids - the most widely used design. Suitable for pipes up to 1000 mm diameter

    Concentric Square Edge 2. Quarter Circle :

    Suitable for measurement of low Reynolds number flows in pipelines of diameter less than 750 mm.

    Quarter Circle

    3. Segmental:

    Suitable for measurement for measurement of dirty fluids and 2 phase flow - allows passage of extraneous matter . Suitable for pipes up to 350mm

    Segmental Eccentric

    ● Non IBR and IBR certified Orifice assembly ● Availableinwidevarietyofmaterials ● Nomovingparts,simpleconstruction ● Maintenance-free

  • ELECTRONET Powered by 16

    ORIFICE FLOW METER ANSI B 16.36 ORIFICE FLANGES

    Orifice Flanges are intended for use instead of standard pipe flanges when an orifice plate or flow nozzle must be installed. Pairs of pressure tappings are machined into the orifice flange, making separate orifice carriers or tappings in the pipe wall unnecessary . The range of orifice flanges covers all standard sizes and ranges, and all common flange materials. Flanges are available in socket weld or weld neck form, and are typically supplied with two ½” NPT tappings in each flange. Jacking screws to ensure ease of removal of the primary flow element are provided. Orifice flanges are supplied complete with bolting and gasket kits.

    INTEGRAL ORIFICE ANSI B 16.36 ORIFICE FLANGE ASSEMBLY

    Typically consisting of a factory assembled section of pipe with an orifice plate mounted between two flanges near the center of the run, terminated with a flange at each end to connect to the process. Building the assembly in the factory allows us to control all the variables which can lead to inaccuracies which can arise if the system is assembled by untrained personnel on-site. Other advantages include reduced installation time; the completed section only needs to be bolted into the pre-prepared line. The complete assembly can be calibrated to provide the maximum accuracy .

    INTEGRAL ORIFICE PLATE ASSEMBLY

    ORIFICE MATERIAL ● 316 Stainless Steel ● Hastelloy®C276 ● Hastelloy®B3 ● Monel®400 ● Titanium ● Tantalum ● PTFEandPVDF.

  • ELECTRONET Powered by

    Ultrasonic M

    eter

  • ELECTRONET Powered by

    DOMESTIC AMR ULTRASONIC FLOW METER ASIONIC 400W • Ultrasonic transit time measurement • Long Battery life • RF Connectivity • Meets OIML(R49) & MID standards • Bidirectional flow measurement • Inbuilt data logging

    ULTRASONIC FLOW METER ASIONIC-400W

    ASIONIC 400W is designed to measures the velocity of a fluid in a sealed pipeline fitted with transducers. This enables calculation of flow and volume based on time of flight principle. ASIONIC 400W is a static water meter which has no moving parts to avoid wear and tear. The electronic unit having inbuilt LCD display to continuously indicate and log / record the following parameters: a. Flow rate b. Total volume c. Forward and reverse flow d. Battery status e. Unit of measurement f. Real time ASIONIC 400W is an integral and hermetically closed static water meter intended for the registration of cold and hot water consumption. ASIONIC 400W is constructed as a vacuum chamber of molded composite material. Thus, the electronics are fully protected against penetration of water. This means that the meter can, without problems, be placed in e.g. bathrooms, where it is sprayed with water daily, and it is also suitable for mounting in meter wells, which are frequently filled with water. The meter can and must only be opened by Oilog ‘s authorized service center by means of special tools, if the meter has been opened, and seal have thus been broken, the meter is no longer valid for billing purpose. Furthermore, the factory guarantee no longer applies. The water meter is powered by an internal lithium battery with up to 10 years lifetime. the battery can be changed by one of the Oilog ’s authorized service center / personnel.

    SALIENT FEATURES

    TECHNICAL SPECIFICATIONS

    17

  • ELECTRONET Powered by

    Q3

    Indicating range (minimum values)

    m³/h

    m³ Q 3 ≤ 6.3

    9 999

    Testing Pressure : 16 Bar Nominal Pressure : 10 Bar Minimum Pressure : 0.1 Bar Pressure Loss : < 0.63 Bar Media Temperature : 0.1 to 60 OC Relative Humidity : 100% Ambient Temperature : 70 OC Max. mean temperature over 24 hours : 55 OC Remote Reading : Wireless M-Bus(incripted-protects personal data against unauthorized monitoring) Reprogramming / Downloading Store Data : Through Optical Port using proprietary Water AMR software Data Storage Facility : Up to 10 Years Battery life : 10 Years RF Frequency : 865.5 MHz Available line sizes : 15, 20, 25, 32, 40 NB MOC : SS / ABS Process Connection : BSP Threading(Male) ALARM

    Battery Low Alarm Meter Tamper Alarm Meter Open Alarm Meter Dry Alarm Reverse Flow Alarm Meter Overload Flow Alarm Meter Overload Pressure Alarm Continuous Zero Flow Alarm Leak / Continuous Flow Alarm Communication Signal / Indication

    The MPE for the upper flow rate zone (Q2≤Q≤ Q4) is ±2% for temperature from 0.1CO and ± 3% for temperature grater than 30OC.to 30CO, The MPE for the lower flow rate zone (Q1≤Q≤ Q2) is ±5% regardless of the temperature range.

    ACCURACY

    ULTRASONIC FLOW METER ASIONIC-400W

    18

  • ELECTRONET Powered by

    DIMENSIONAL DETAILS

    D : Diameter H : Height L : Length

    ELECTRONET MODEL :

    SR. NO :

    Meter Size

    L (mm)

    D (mm)

    H (mm)

    Flow Range (m³ /hr)

    Min Normal Max 15 NB 88.9 100 180 0.03 1.2723 6.4

    20 NB 98.4 100 180 0.11 2.2619 11

    25 NB 107.9 100 180 0.18 3.5341 18

    32 NB 117.5 100 210 0.29 5.7906 29

    40 NB 127.0 100 210 0.45 9.05 45

    50 NB 152.4 100 210 0.71 14.14 71

    H

    L

    D

    Note : ● Typical mounting dimensions for reference ● Standard factory calibration for 0 to 2m/Sec velocity ● Max. Flow range in LPH / LPM is upto 9999

    *Due to our continuous product revisions, Design, Speci› cations and Model Number are subject to change without notice.

    *Accuracy de› ned at lab conditions & higher sampling rate.

    09 None 15 mm to

    50 mm 02 SS 03 GSM 01 CS / MS 02 RS 485

    SERIES Line Size Flange Communi- cation Port

    ASONIC 400 50 mm A 01 B 02

    ORDERING INFORMATION

    ULTRASONIC FLOW METER ASIONIC-400W

    19

  • ELECTRONET Powered by 19

    SALIENT FEATURES • Ultrasonic measurement using transit time technology • EMI / EMC Compliant • Single / Dual / Quad beam technology for precise measurements • Maintenance free • Excellent long term stability & reliability • Inline / Hot retractable sensor assembly • Simple & cost effective construction • Empty pipe indication • Low start flow measuring capability to earn revenue from every drop of liquid

    delivered • IP 68 Construction • No pressure drop

    ULTRASONIC FLOW METER ASIONIC-200

    The Serie ASIONIC-200 is a micro-controller based full bore type Ultrasonic Flow Meter, specially used for various industrial applications. These flow meters accurately measures the flow rate of liquid in closed pipes. Due to its simple& rigid design, the flow meter is an obstruction-less & maintenance free instrument in place of conventional mechanical Flow measuring devices. The system is well suited to most environments. Programming of the flow meter is simple and can be accomplished with 4 keys available on instrument , It provides access to an extensive range of diagnostic information. Meter is manufactured in several flow meter consoles to meet the specific requirements of various applications.

    DESCRIPTION

    : Sonically conductive liquids : 200 cp maximum : 50 NB to 2000 NB : 6 digit for Flow Rate & 8 digit for Totalised Flow : As per requirement (Factory Calibrated) : Single, Dual & four path

    Media Viscosity Line Size Display Calibration Range Acoustic Paths Accuracy* :

    Turbidity Linearity Repeatability Temperature Coefficient Process Temperature Process Pressure Material of Construction Power Supply

    Communication Port Analog Output Response Time Transmitter Enclosure Process Connections Operating Conditions Data logging Sensor Pair Sensor MOC Electronics

    : Smaller than 10,000ppm (mg/ltr) with a low level of air bubble content : ± 0.5% of M.V. : ± 0.2% of M.V. : ± 0.05% perOC : -20OC to 85OC maximum : 15 kg/cm2maximum : Flow tube - SS / MS / CS : 1) 230V AC,50 Hz

    2) 24V DC,+20%, -15% / 20 Watts Max. : RS-485 MODBUS RTU : 4 - 20 mA : < 1Sec : Die Cast Aluminum IP-66, flow tube IP-68 : ANSI 150 flanged, as per table B 16.5 : Temperature -20 to 75OC / Humidity 5 to 95% non condensing : for 10 years (per day 1 sample) : As per requitement : SS 316 : 1) Integral 2) Remote

    Note : For process conditions other than above, please consult factory.

    TECHNICAL SPECIFICATIONS

    Line Size ±0.5% of MV ±1% of MV ±2% of MV 50 to 300NB Single path ---- ---- 350 to 600NB Dual path Single path ---- 650 to 2000NB Four path Dual path Single path

  • ELECTRONET Powered by 19

    ULTRASONIC FLOW METER ASIONIC-400W

    Fig. 2 Side View

    Note:- Standard factory calibration for 0.2 to 2m/Sec velocity Typical mounting dimensions for reference Max. Flow range in LPH / LPM is up to 999999 For line size above 600NB consult factory for dimensions & flow range

    W Fig. 1 Front View

    H

    A

    A S I ONIC 2 0 0

    ELECTRONET

    DIMENSIONAL DETAILS OF FLANGE(AS PER ASA150 # B-16.5): Line Size Flange

    Diameter ‘D’

    Diameter of Raised Face

    ‘R’

    Diameter of Bolt Hole

    Circle ‘DBC’

    Diameter of Bolt Hole

    No. of

    Holes

    Flange Distance

    ‘FD’

    Flow Range(m3/hr) at 0.03m/s to 6m/s

    Inch NB Minimum Maximum 2” 50 152.4 92.1 120.6 19.0 4 200 0.212 42.4115

    2 ½ ” 65 177.8 104.8 139.7 19.0 4 200 0.358 71.675 3 ” 80 190.5 127.0 152.4 19.0 4 200 0.542 108.573 4” 100 228.5 157.2 190.5 19.0 8 250 0.848 169.646 5 ” 125 254.0 185.7 215.9 22.2 8 250 1.325 265.071 6” 150 279.4 215.9 241.3 22.2 8 300 1.9085 381.703 8” 200 342.9 269.9 298.4 22.2 8 350 3.3929 678.584 10” 250 406.4 323.8 361.9 25.4 12 450 5.3014 1060.28 12” 300 482.6 381.0 431.8 25.4 12 500 7.6340 1526.81 14” 350 533.4 469.9 476.2 28.6 12 500 10.3908 2078.16 16” 400 596.9 533.4 539.7 28.6 16 600 13.5716 2714.33 18” 450 635.0 584.2 577.8 31.7 16 600 17.1766 3435.33 20” 500 698.5 692.1 635.0 31.7 20 600 21.2057 4241.15 24” 600 812.8 692.1 749.3 34.9 20 600 30.5362 6107.25

    DIMENSIONAL DETAILS

    INSTALLATION DRAWING

    ASIONIC 200

    ELECTRONET

    10D

    Pipe Support

    Pipe Support

    Valve

    Pipe Support

    Pipe Support

    Flow In

    Valve

    Flow Out

    Valve

    5D

  • ELECTRONET Powered by 19

    ULTRASONIC FLOW METER ASIONIC-400W

    ORDERING INFORMATION

    *Due to our continuous product improvisations, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions.

    04 15 mtr 03 650-

    2000NB 03 Four 08 Other 03 10 mtr

    02 350-600NB

    02 Remote 02 Dual 02 Fixed Inline

    02 SS316 08 Other 02 SS 304 02 4-20mA + RS485 02 24V DC 02 5 mtr

    01 50-300NB 01 Local 01 Single 01 Hot retractable insertion

    01 MS 01 ASA 150 01 Aluminum 01 4-20mA 01 230V AC 01 0 mtr

    SERIES Line Size Electronics No. of paths Sensor Construction

    Flow Tube Flange Rating Electronics Enclosure

    Output Power Supply Remote Cable Length

    ASIONIC 200 A 01 B 01 C 01 D 01 E 01 F 01 G 01 H 01 I 01 J 01

  • ELECTRONET Powered by

    • Increased Meter Reading Efficiency Through High Performance AMR. • Accurate meter reading collection. • Leak, tamper, and reverse flow alarms. • Highly reliable RF communication with data encryption facility. • Innovative remote Walk By automated reading solution. • Uploads .CSV file to PC from Handheld unit over USB. • Frequent transmit mode. • Local display of HHU for operator convenience.

    SALIENT FEATURES

    DESCRIPTION The AMR 600 offers Walk By automated reading solution for efficient data collection with fewer efforts. Integrated RF transmitter with our own water meters makes it even more reliable and Cost effective. Eliminates the need for physical access or visual inspection of water meters, allowing gathering data from meters located in paces that are not easily accessible. Also eliminates the errors were present in manual meter reading system.

    TECHNICAL SPECIFICATIONS RF frequency band Display Transmission Interval RF output power Reception sensitivity Modulation technique Flow Meter Parameter readings

    HHU data Output Handheld memory Size Handheld Power Supply RF Bit rate

    : 865 MHz – 867 MHz : 16 x 2 LCD : 13 Sec – 17 Sec : +12 dBm : Down to -107 dBm : FSK (Phase Shift Keying) : Meter ID, Total Flow count, Battery Low flag, Back Flow flag, Leak detection flag, Meter Tampering flag

    : CSV file over USB : 512 Kb (4000 Records), Expandable (Optional) : 2.4 V AA cell batteries : 25 kbps

    *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions & higher sampling rate.

    AMR OPERATING SCHEME

    AUTOMATIC METER READER AMR 600

    20

  • ELECTRONET Powered by

    Turbine Flow M

    eters

  • ELECTRONET Powered by

    TWO WIRE TURBINE FLOW METER FL-100

    ● 2 wire System ● Simple & cost effective construction ● Suitable for non conductive clear liquids. ● Local display as 8X1 LCD ● Durable & Versatile ● Easy maintenance ● Die Cast Aluminium IP-68 housing ● Remote display optionally available

    SALIENT FEATURES

    DESCRIPTION

    The FL-100 is a 2 wire turbine flow transmitter specially used for various industrial applications. The flowing media engages a vaned rotor causing it to rotate at an angular velocity proportional to flow rate. The pick-up coil senses the spinning motion of the rotor inside the pipe & converts it into a pulsating electrical signal. Summation of the pulsating electrical signal is directly related to the total flow. The frequency is linearly proportional to flow rate which is converted to electrical signal 4 - 20 mA .

    TECHNICAL SPECIFICATIONS

    Media Viscosity Line Size Display

    : : : :

    Transmitter Electronics :

    Remote Electronics Cable : Type of Output :

    Calibration Range : Accuracy : Linearity : Repeatability : Pressure Drop : Turn down ratio : Process Temperature : Process Pressure : Material of construction :

    Power Supply : Power Consumption : Response Time : Temperature Coefficient : Transmitter Enclosure : Process Connections :

    Mounting Operating Conditions

    : :

    Liquids (Clear) 100 cp max 15 NB to 150 NB 8 x 1 LCD - 4 digit for flow rate & 8 digit for totalised flow (Flow rate & totalised flow will be visible through toggle key) Option 1 : Integral Option 2 : Remote 25 mtr max 1) 4 to 20 mA DC 2) Pulse - 30mA Peak-Peak As per requirement (Factory Calibrated) +/- 1% of F. S. (For 20 to 100% flow) +/- 1% +/- 1% Approx. 0.28 kg/cm2 at max. Flow 10 : 1 to 100 : 1 0 to 850C max 0 to 10 kg/cm² max Bearings - Tungsten Carbide Sleeve / V Jewel Rotor - SS 410 / 17.4 PH Shaft - Tungsten Carbide Body / Support / Flange - SS 24 V DC < 0.5 VA < 100 mSec +/- 0.01% per 0C Die Cast Aluminum IP 68 1)ASA 150 RF ,flanged as per table B 16.5 2) BSP (M), Threaded ( Upto 50 NB only) 3)SS Tri-clover ( Upto 50 NB only) In-Line ( Horizontal or Vertical ) Temperature 0 to 55 0C / Humidity 5 to 95% non condensing

    Note : For process conditions other than above please consult factory.

    21

  • ELECTRONET Powered by

    DIMENSIONAL DETAILS

    D : (OD)Outer Diameter of Flange No. of Holes : For ½” to 3” & 4” to 6” C : Thickness of flange R : Diameter of Raised face DBC : Diameter of bolt circle d : Size of Hole FD : Flange Diameter

    Magnetic pick-up assembly

    SS 316 Flange RF

    DBC

    D mm

    Line Size

    Flow Range Flange Details ANSI 150(B 16.5)

    m³/hr LPM D C R DBC d FD 15NB 0.4 to 4.0 6.6 to 66.6 88.9 11.2 35.1 60.5 15.8 200 20NB 0.8 to 8.0 13.3 to 133.3 98.6 12.7 42.9 69.9 15.8 200 25NB 1.6 to 16.0 26.6 to 266.6 108.0 14.2 50.8 79.3 15.8 200 40NB 3.4 to 34.0 56.6 to 566.6 127.0 17.5 73.2 98.6 15.8 200 50NB 6.8 to 68.0 113.0 to 1133.0 152.4 19.1 90.2 120.7 15.8 200

    100NB 13.5 to 135.0 225.0 to 2250.0 190.5 23.9 127.0 152.4 19.1 200 150NB 27.0 to 270.0 450.0 to 4500.0 228.6 23.9 157.2 190.5 19.1 250

    FD

    30 mm D

    P

    FL-100

    100 mm

    R

    d

    Note : ▪ Typical mounting dimensions for reference

    ORDERING INFORMATION

    *Due to our continuous product revisions, Design, Specifications and Model Number are subject to change without notice. *Accuracy defined at lab conditions.

    04

    900 psi

    08

    Other 08

    Other 03

    Triclover

    03

    600 psi 03 25 Mtr

    15 mm to 150 mm

    02

    Remote 02

    V Jewel 02

    17.4 PH 02

    Pulse (Open Collector) 0

    2 Flange

    d 02

    300 psi 02 10 Mtr

    01

    Integral 01

    Tungsten Carbide Sleeve

    01 SS 410 01

    4-20 mA 01

    Threaded

    01

    150 psi 01 5 Mtr

    SERIES Line Size Electronics Bearing Rotor Output Process Connection

    Pressure Ratting

    Remote Cable Length

    FL-100 65 mm A 02 B 01 C 01 D 01 F 01 G 03 H 03

    TWO WIRE TURBINE FLOW METER FL-100

    22

  • ELECTRONET Powered by

    Flow Indicator / Totalizers

  • ELECTRONET Powered by

    ●Averaging of inputs for turbulent flow ●Software calibration

    Input : Linear / Square Rooted 4-20 mA, 1-5V / 0-5V, 0-10 KHz Display : 4 digit, 0.5” Red LED for Flow Rate & 8 digit, 0.3” Red LED for Totaliser Accuracy : Better than ± 0.25% of F. S. Power Supply : 90 - 250V AC, 50 Hz; OPTIONAL : 24V DC Mounting : Flush of the Panel DIN std. OR wall mounting WP enclosure Transmitter Supply : 24V DC, 30 mA Retransmission Output : 4 - 20 mA / 0-5 V, Isolated Alarm Output : Potential free Relay Contact - 2 nos. for High, Low / Batch Communication Port : RS 485 / RS 232 supporting MODBUS RTU protocol

    ● Averaging of inputs for turbulent flow ●Optional : Available with 3 inputs for Pressure, Temperature,

    Compensated Flow ● Optional : Available for OPEN CHANNEL Flow

    measurement Input : Linear / Square Rooted / 10 Point Linearisation Table 4-20 mA, 1-5 V / 0-5 V, 0-10 Khz Accuracy : Better than ± 0.25% of F. S. Power Supply : 90 - 250V AC, 50 Hz; OPTIONAL : 24V DC Mounting : Flush of the Panel DIN std. OR wall mounting WP enclosure Transmitter Supply : 24 V DC, 30 mA Retransmission Output : 4 - 20 mA / 0-5 V, Isolated Alarm Output : Potential free Relay Contact for High, Low / Batch Communication Port : RS 485 / RS 232 supporting MODBUS RTU protocol

    FLOW INDICATOR TOTALISER FL-244

    SPECIFICATIONS

    FLOW INDICATOR TOTALISER Micro-controller Based with LCD FL-600 / FL-600 PTC / FL-600 OC

    SPECIFICATIONS

    23

  • ELECTRONET Powered by

    ● Multi color bargraph display with 4 digit LED display for process variable

    ● Cold junction compensation for Thermocouple input. No. of Bargraph Segments : 101 Nos. No. of Channels : 01 No. (OPTIONAL : DUAL CHANNEL) Input : LINEAR : 4-20mA, 0-20mA, 0-6V, 1-5V, -20µA to +20µA / RTD /THERMOCOUPLE Accuracy : Better than ± 0.5% of F. S. for TC & ± 0.1% F.S. for other inputs Power Supply : 24V DC ± 10% OPTIONAL Transmitter Supply : 24 V DC, 30 mA / 60 mA Output : 4-20 mA / 0-5 V, Isolated per channel, Alarm Output : Potential free Relay Contact - 4 nos. Communication Port : RS 485

    ●Cold junction compensation for Thermocouple input. ●Open sensor indication, Software calibration.

    Input : 1 No; Universal - RTD / Thermocouple / Current /Voltage Display : 4 x 1 digit, 0.8”, 7 seg. Red LED Accuracy : Better than ± 0.5% of F. S for TC & ± 0.25% F. S. for other inputs Power Supply : 1) 24 V DC ; 2) 90 - 250 V AC, 50 Hz Enclosure : 1) Din std. ; 2) Weather-proof, IP-65; 3) Flameproof OPTIONAL Transmitter Supply : 24 V DC, 30 mA Retransmission Output : 4 - 20 mA / 0 - 5 V, isolated Alarm Output : Potential free Relay Contact - 2 nos. Communication Port : RS 485 / RS 232 with MODBUS RTU Protocol

    SPECIFICATIONS

    SPECIFICATIONS

    BARGRAPH INDICATORS DPI-160-1/ DPI – 160 -2

    UNIVERSAL INPUT PROCESS INDICATOR DPC-808

    24

  • ELECTRONET Powered by

    ●Cold junction compensation for Thermocouple input. ●Open sensor indication , Software calibration. No. of Input : 01 No. (OPTIONAL UPTO 3 INPUTS) Input : Universal - RTD / Thermocouple / Current /Voltage Display : 4 x 1 digit, 0.8”, 7 seg. Red LED (OPTIONAL – UPTO 3 DISPLAYS) Accuracy : Better than ± 0.5% of F. S for Thermocouple & ± 0.25% F. S. for other inputs Power Supply : 1) 24 V DC ; 2) 90 - 250 V AC, 50 Hz OPTIONAL Transmitter Supply : 24 V DC, 30 mA Retransmission Output : 4 - 20 mA / 0 - 5 V, isolated Alarm Output : Potential free Relay Contact - 2 nos Communication Port : RS 485 / RS 232 with MODBUS RTU Protocol

    ●Individual alarm output for each channel. ●Long lasting battery backup for memory. ●Cold junction compensation for TC input. No. of Channels : 8/16 nos. Input : DEDICATED : RTD/ TC/mA/ Voltage OR UNIVERSAL Display Scan Time : Programmable from 1 to 99 seconds Power Supply : 90 - 250 V AC, 50 Hz / 24 V DC Accuracy : Better than ± 0.25% F. S. for TC & RTD, ± 0.1% F. S. for other inputs Response Time : < 100 mSec per channel Output (common for all channels) : RS 232/RS485 ; Printer Port (80 column parallel) ; Relay output OPTIONAL Alarm Output (Individual per channel) : Potential free Relay Contacts for High & Low

    DIGITAL PROCESS INDICATOR DPC-100/200/300

    PROCESS SCANNER SC-204

    SPECIFICATIONS

    SPECIFICATIONS

    25

  • ELECTRONET Powered by

    ●Input from pH/ORP/Conductivity/DO2 Electrode and 4-20mA.

    ●Auto temperature compensation & Inbuilt memory for data logging. Power Supply : 1) 24 V DC ; 2) 85 to 265V AC, 50Hz Type of Inputs : From any pH / ORP / Conductivity / DO2 Electrode Input Range : 1) pH, 0 to 14 pH

    2) ORP, -2000 to 2000 mV 3)Conductivity, 0.01µS/cm to 10mS/cm 4)DO2, 0 to 20 ppm 5)Temperature, 0 to 150 deg C

    Output : 1) 4-20 mA DC, HART (HART Optional for one channel) 2)Potential free Relay Contact (1 c/o, 1 Amp) - 2 nos,

    programmable 3)Serial communication RS485/RS232

    ●On-line measurement. ●Auto/Manual temperature compensation

    Power Supply : 24 V DC Display : Local display 128X64 COG with backlit Type of Input : From Conductivity / PH / DO Electrode (Single I/P) Type of Output : 4 - 20 mA DC with HART COMMUNICATION, 2 wire Isolated Accuracy : ± 0.25% F. S. Response Time : < 1000 mSec Process Connection : Through BNC connector / Through Terminals Dimensions : 135 (H) x 249 (W) including cable gland x 170 (D) in mm approx. Mounting : 2” Pipe Mounting Housing : Cast aluminium with epoxy coating NEMA 4X (IP-65)

    ANALYTICAL TRANSMITTERS CT-100S / PH-100S / DO-100S

    DUAL INPUT ANALYSER UAC 100 Single / Dual channel.

    SPECIFICATIONS

    SPECIFICATIONS

    26

  • ELECTRONET Powered by

    ●Large selection of electrodes to suit a wide variety of applications.

    ●Easy to install with stable performance & reliable measurement ●Range : 1) For pH, 0 to 14 pH

    2) For ORP, -2000 to 2000 mV 3) For Conductivity, 0.01µS/cm to 10mS/cm 4) For DO2, 0 to 20 ppm 5) For Temperature, 0 to 150 deg C System Accuracy : ± 2 % OF F.S. Operating Temperature Range : Customer to specify Operating Pressure : Customer to specify Temperature Compensation : Through RTD upto 100o C Cable Length : Upto 3 Mtrs

    ●Single channel ON/OFF Indicator controller. ●Open sensor indication. ●Software calibration.

    Power Supply : 1) 24 V DC ; 2) 90 - 250 V AC, 50 Hz Type of Input : From Conductivity / PH / DO Electrode (Single I/P) Display : 4 digit, 0.5” LED for pH & 16X2 LCD for Conductivity & DO Accuracy : Better than ± 0.25% F. S. Process Connection : Through BNC connector / Through Terminals Enclosure : 1) DIN Std. 2) Weather-proof, IP-65 Mounting : Flush of the Panel DIN std. & wall mount for FLP/WP enclosure Output : 1) 4-20 mA DC

    2)Potential free Relay Contact (1 c/o, 1 Amp) - 2 nos, programmable

    3)Serial communication RS485/RS232

    ANALYTICAL INDICATOR CONTROLLERS CT-801 / PH 104 / DO 801

    ANALYTICAL SENSORS CONDUCTIVITY SENSOR / pH - SENSOR / DO2 - SENSOR

    SPECIFICATIONS

    SPECIFICATIONS

    27

  • Mechanical M

    eters

  • ROTARY VANE WHEEL DRY-DIAL WATER METER

    DESCRIPTION

    TECHNICAL SPECIFICATIONS

    FEATURES

    Magnet drive, magnet-proof and resistance exterior magnet interference. Keep the reading easy and clear in a long-term service.

    * Magnet drive, magnet-proof and resistance exterior magnet interference.

    * Keep the reading easy and clear in a long-term service.

    * The cover can be turned discretional.

    * Selected high quality materials for steady & reliable characteristic and good looking.

    * Brass or stainless steel body, hot water meter, magnet-proof device and remote reading transmission system for option.

    Note: technical data conforms to ISO4064.

    Main Technical Data

    Size (mm) Q3/Q1

    Max Flow (m³/h)

    Nominal Flow (m³/h)

    Transitional Flow (m³/h)

    Min Flow (m³/h)

    40 50 20 16 0.512 0.320

    40 80 20 16 0.320 0.200

    Dimensions and weight

    Type size (mm) Length (mm)

    Width (mm)

    Height (mm)

    Connecting Thread

    Weight (kg)

    LXSG-40E 40 245 122 149 G2B 4.8

    28

  • ROTARY VANE WHEEL MULTI JET DRY METAL LXSG WATER METER

    DESCRIPTION

    FEATURES

    Rotary vane wheel multi jet water meter Dry type and magnet drive water meter Easy reading High accuracy Remote water meter for option. 201 or 304 stainless steel water meter Size 15mm-25mm ISO 4064 class B Horizontal type and vertical type are available Pulse output for option

    1. High quality stainless steel material, NO.201 or NO.304 2.Multi jet, dry dial or wet dial are available 3.Regular type and pulse-output communication for option. 4.Nice looking and perfect performance. 5.Magnet drive water meter, magnet-proof and resistance exterior magnet interference. 6.Water meter can keep the reading easy and clear in a long-term service. 7.The cover of water meter can be turned discretional. 8.Selected high quality materials for steady & reliable characteristic and good looking. 9.Brass or stainless steel body, hot water meter, magnet-proof device and remote reading transmission system for option

    Note: technical data confirm to ISO4064

    Water meter size and basic information are below: TYPE SIZE LENGTH WIDTH HEIGHT CONNECTING THREAD

    mm LXSG-15E 15 165 94/103 111 G3/4B LXSG-20E 20 195 94/103 111 G1B LXSG-25E 25 225 118 122 G1 1/4B LXSG-32E 32 230 118 122 G1 1/2B LXSG-40E 40 245 122 149 G2B LXSG-50E 50 280 125 184 G2 1/2B 300 165 172 GB4216.4-84 D=Φ165 D=Φ125

    TECHNICAL SPECIFICATIONS

    29

  • Valves and other accessories

  • JY -101 Brass gate valve Forged brass body size: 1/2“; 3/4“; 1“; 1-1/4“; 1-1/2“; 2" ;2-1/2“; 3“ and 4"

    JY -102 Brass gate valve Forged brass body size: 1/2“; 3/4“; 1“; 1-1/4“; 1-1/2“; 2" ;2-1/2“; 3“ and 4"

    JY -103 Brass gate valve (CXC) Forged brass body size: 1/2“; 3/4“; 1“; 1-1/4“; 1-1/2“; 2" ;2-1/2“; 3“ and 4"

    BRASS GATE VALVES

    30

  • JY -104 Brass gate valve Forged brass body size: 1/2“; 3/4“; 1“; 1-1/4“; 1-1/2“; 2”

    JY -105 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -106 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS GATE VALVES

    31

  • JY -107 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS GATE VALVES

    JY -108 Brass gate valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -109 Brass compression gate valve Forged brass body size 15mm; 18mm; 22mm; 28mm; 35mm; 42mm; 54mm

    JY -125 Brass gate valve with flange Cast brass body size 11/2" 2" 21/2" 3" 4"

    32

  • JY -110 Brass stop valve Forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2

    JY -111 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -112 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS STOP VALVES

    33

  • JY -113 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -114 Brass stop valve Cast or forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -115 Brass stop valve Cast or forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS STOP VALVES

    34

  • JY -116 Brass compression stop valve forged brass body size 15mm 22mm

    JY -117 Brass stop valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS STOP VALVES

    JY -124 Brass stop valve Cast or forged brass body size " 2

    35

  • JY -118 Brass check valve Cast brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3"4"

    JY -119 Brass check valve (CXC) Cast brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -120 Brass spring check valve forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"

    BRASS CHECK VALVES

    36

  • JY -121 Brass foot valve With stainless steel filter forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    J Y -122 Brass foot valve With brass filter Cast brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY -123 Brass Y pattern strainer With stainless steel filter Cast or forged brass body size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS FOOT VALVES

    37

  • JY-201 Brass ball valve (standard port) F/F Forged or cast brass body Steel handle size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"

    JY-202 Brass ball valve (Full port) F/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"

    JY-203 Brass ball valve (Full port) M/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    BRASS BALL VALVES

    JY-204 Brass ball valve (Full port) M/M Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    38

  • JY-205 Brass ball valve with drain (Full port) Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY-206 Brass ball valve (standard port) F/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"

    BRASS BALL VALVES

    JY-207 Brass ball valve (Full port) F/F Forged brass body Steel handle with plastic sleeve size 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    JY-208 Brass ball valve (Full port) F/F Forged brass body Steel handle with plastic sleeve size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

    39

  • ELECTRONET Powered by

    CONTACT US USA – Oilog Inc. 10370 Richmond Ave. Houston TX 77052. P: +1 832 778 8811 FAX: +1 832 778 8812 West Africa Plot 282 Trans Amadi Industrial Layout, P.M.B. 074, Port Harcourt, Nigeria. P: +234 84 463256 Middle East Region, India A-15, Shri Sadguru Saibara Co-operative Housing Society Ltd. 59 Nehru Rd. Vakola Bridge, Santacruz (E), Bombay. P: +91 22 6108036, 6174564 FAX: +91 22 6108029, 6150656 Email [email protected]

    OUR AGENT ON WATER SOLUTIONS Track United Cia. Ltda. Santo Domingo De Los Tsachilas Parroquia: SANTO DOMINGO DE LOSCOLORADOS Calle: VIA QUEVEDO Número: S/N lntersección: CARLOTA JARAMILLO Referencia: JUNTO A LA GASOLINERA MOBIL Kilómetro: 4l12. Ecuador Contact: Ing. Joao Reinoso Representante Legal Email: [email protected]

  • ELECTRONET Powered by

    Slide Number 1Slide Number 2Slide Number 3Slide Number 4Slide Number 5Slide Number 6Slide Number 7Slide Number 8Slide Number 9Slide Number 10Slide Number 11Slide Number 12Slide Number 13Slide Number 14Slide Number 15Slide Number 16Slide Number 17Slide Number 18Slide Number 19Slide Number 20Slide Number 21Slide Number 22Slide Number 23Slide Number 24Slide Number 25Slide Number 26Slide Number 27Slide Number 28Slide Number 29Slide Number 30Slide Number 31Slide Number 32Slide Number 33Slide Number 34Slide Number 35Slide Number 36Slide Number 37Slide Number 38Slide Number 39Slide Number 40Slide Number 41Slide Number 42Slide Number 43Slide Number 44Slide Number 45Slide Number 46Slide Number 47Slide Number 48Slide Number 49Slide Number 50Slide Number 51Slide Number 52Slide Number 53