SHABEER AHMADAGE: 22 Years
Job Experience: 3.6Years Post Applied: Process Plant Operator
: : Urea plant CCR-1, Fatima Fertilizer company,Sadiqabad.Urea plant CCR-1, Fatima Fertilizer company,Sadiqabad.
: : (+92-3067722471),(+92-3360020122)(+92-3067722471),(+92-3360020122)
:: [email protected]@gmail.com
: shabeer.ahmad2471: shabeer.ahmad2471
Objective My goal is to become associated with a company where I can utilize my skills and gain further experience while enhancing the company’s productivity and reputation with the best use of my dedication, determination and resourcefulness.
Personal Information
Father’s Name Muhammad AshiqDate of Birth 17-12-1993Religion IslamMarital Status SingleDomicile Multan(Punjab)Nationality PakistaniC.N.I.C. Number 36303-2354051-7
Permanent address
Urea plant Fatima Fertilizer company, Sadiqabad.
Course Title Particular Year of Passing Percentage/ Marks Marks Board
D.A.E (Chemical)
2011 75.67% 2573/3400 P.B.T.E Lahore
Metric (Science) 200882% 697/850 BISE Multan
Professional Experience
Technical skills
Worked at following equipments &
machinery.
Centrifugal Compressors
P D Pumps Centrifugal
Pumps
FATIMA FERTILIZER,UREA UNIT:Enhancing personal professional experience at ever expanding Petro-Chemical industry, Fatima fertilizers. Working as plant operator in a challenging environment handling emergency situations along with obtaining thorough knowledge about STAMICARBON Technology used for UREA Production for 1.5 years (from 10-10-12 to till date).
Steam Turbine: 15 stages Steam Turbine of Impulse & Reaction Induction, Condensing and
Extraction type made by Siemens. 8.1M.W power having latest electronic governor System (WOODWARD 505E).
P D Compressors Surfaces
Condenser Electronic
Governors Condensing
Turbines
Safety & skill improvement
courses
Fire fighting Rescue
training Work permit
procedure Process
control Centrifugal
pump &compressor
Steam & steam turbine
Heat and heat exchangers
Safety standardsIMSISO:9001
Environment al Management System(EMS)
ISO:14001 Quality
control Management System(QMS)
ISO: 18001 Occupational
Health &
CO2 Compressor: Compressor is steam turbine Driven. 04 stages CO2 compressor (centrifugal type) made by HITACHI Japan 02 casing one horizontal split and second vertical split H2 converter is also introduced b/w two stages to remove Hydrogen Operating pressure 147 Kg/Cm2 and flow 47 Ton/Hr having latest surge control
system. Synthesis and High Pressure Decomposition Section:
Pool Reactor It consists of two parts (cooling part, adiabatic part) with operating conditions 145 kg/cm2 and 174-184 oC.
High pressure stripper Design CO2 stripping {falling film evaporator).Operating condition,145 kg/cm2 and 175-190 oC
High pressure scrubber Spherical scrubber having capacity of 9m3.Having ability to scrubs of the off gasses of the pool reactor by fresh ammonia and carbamate.
High Pressure Pumps High pressure Ammonia Pump (EBARA)
Multi stage centrifugal Pump (10 Stage) Motor Driven, 0.6 MW, 6526 RpmOperating Pressure 180 kg/cm2.
High pressure Carbamate Pump (EBARA) Multi stage centrifugal Pump (08 Stage) Motor Driven, 0.35 MW, 7249 Rpm
Operating Pressure 170 kg/cm2. High Pressure Flush pump (150 Kg/cm2). N/C analyzer & N/C metering system. Vacuum type leakage Detection system.
Low pressure (lP) and Vacuum Section. To purify and achieve 99 % urea solution concentration, following equipments are used in Low pressure and Vacuum sections with operating conditons:
Rectifying column 4.5 kg/cm2 (a) & 135 oC Low pressure carbonate condenser 3.5 kg/cm2 (a) & 50 oC Pre evaporator 0.45kg/cm2 (a) & 85 oC Double Evaporator 0.25kg/cm2 (a) & 130 oC , 0.02kg/cm2 (a) & 140C. Evaporator condenser 0.27kg/cm2 (a) & 50 oC
Waste water & process condensate treatment section (PCT): Double desorber€€ [3.8-4.0 kg/cm2 (a)] having 41 sieve trays to avoid back
mixing and solution down comers. A hydrolyser to break urea to its reactants (NH3 + CO2) by using 21 kg/cm2
steam also provided with 16 sieve trays and down comers.
Safety assessment series(OHSAS)
PSM Process
Safety Management System having 22 elements divided into two parts.
1 st Risk base consists on 10 elements
2 nd Behavior base elements consists on 12 elements.
Job Responsibilities: Reporting to “In-Charge Department” according to my responsibilities include: Understand the control logic and its valid reasoning. Smooth operation of plant by adjusting the process control variable according
to SOP. Maintaining the record of plant operating parameters for best communication. To handle the start up & shut down activities. To control plant maintenance under the safety environment. Strictly application of personal & equipment safety. Execution of “Permit to work” system for safely handling over jobs. Deep understanding with the equipment details & routine behavior. Suggest the suitable modification in working procedures to eliminate the
hazard &to improve the performance of various equipment, Monitoring of process plant parameters. Sound knowledge of the safety precautions & standard used during
the time of catastrophic conditions.
Skill & Competences
Effectively handled emergencies like compressor, turbine tripping Coordinating thirty days (injury/fire free) shutdown for major repair &
modification two times. Handling of emergencies in case of fire & ammonia leakages Commanding in language (Urdu, English)
Safety Trainings: Toxic gas release & its handling. Fire fighting & use of fire extinguisher. Explosive gas release. Working at height. Electric short circuit prevention Working at Confined space & validation of vessel entry permits. Importance of PPE’s (Personal Protection Equipments). Permit to work system.
SBM (stand by man) training.
Achievements Successfully handling of the following emergencies Cooling water failure Power failure Instrument Air failure Steam failure