Flex Pins Lock Smart- Tip™ probe into test unit. Press firmly. With thumb and forefinger, squeeze chamber 1 until capsule breaks. Gently shake test unit for 2-3 seconds. 3 Test Preparation 4 Identification Do not continue unless probe is locked below the Flex Pins and cannot be removed from the test unit. STOP 5 Proceed to Dilution (steps 6-9), regardless of whether or not a color appeared. Results With , thumb and forefinger squeeze chamber 2 until capsule breaks. Gently shake test unit for 2-3 seconds. Dilution 6 7 Wait 5 minutes. The test window will warm up. This is normal. With , thumb and forefinger squeeze chamber 3 until capsule breaks. Dilution 8 Gently shake test unit for 2-3 seconds. 9 The test window will warm up. This is normal. The appearance of an intense yellow color indicates the presence of Piperonal. The appearance of an orange color indicates the presence of Safrole or 1-phenyl-2-propaneone (BMK). If none of the above colors develop, the above list precursors are not present. The appearance of a red-brown color indicates the presence of 3,4-Methyleneedioxyphenyl-2 propanone (PMK, MDP2P). Procedure Card for IDT0270 DRUG PRECURSOR TESTING KITS Read Before Use As a precaution, gloves and eye protection should be worn when handling drug substances and using test units. Do not puncture any part of unit. Do not remove probe once a capsule is broken. In the unlikely event of a spill, rinse affected area thoroughly with water. Keep out of reach of children. All results are presumptive. If necessary, further testing by a competent drug testing lab can provide additional identification. TM MDMA/ METHAMPHETAMINE PRECURSORS Substance Test Disposal After Dilution, the test kit is safe to dispose of in the trash. ID enta enta World Leader in Forensic Products 01-19 Sample suspected substance. 1 2 Test Preparation Remove the Smart-Tip™ probe from test unit. Touch Smart- Tip™ probe to sample. Make sure the tip is completely covered. Draw a sample using the pipette. Insert the tip of the pipette into the hole of the test unit. Place 2-3 drops into the hole. Liquid Powder Manufactured by IDenta Ltd www.identa-corp.com Patented Technology Made in Israel

Procedure Card for IDT0270 · 2021. 1. 13. · TM MDMA/ METHAMPHETAMINE PRECURSORS Substance Test Disposal After Dilution, the test kit is safe to dispose of in the trash. IDenta

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • 5

    FlexPins

    Lock Smart-Tip™ probe into test unit. Press firmly.

    With thumb and forefinger, squeeze chamber 1 until capsule breaks.

    G e n t l y shake test unit for 2-3 seconds.

    3

    Test

    Pre

    para

    tion 4

    Iden

    tific

    atio

    n

    Do not continue

    unless probe is locked

    below theFlex Pins

    and cannot be removed

    from the test unit.

    STOP

    5

    Proceed to Dilution (steps 6-9),regardless of whether or not a color appeared.

    Resu

    lts

    With , thumb and forefingersqueeze chamber 2 until capsule breaks.

    Gently shake test unit for 2-3 seconds.

    Dilu

    tion

    6 7Wait 5 minutes.

    The test window

    will warm up.

    This is normal.

    With , thumb and forefingersqueeze chamber 3 until capsule breaks.

    Dilu

    tion

    8 Gently shake test unit for 2-3 seconds.9

    The test window

    will warm up.

    This is normal.

    The appearance of an intense yellow color

    indicates the presence of Piperonal.

    The appearance of an orange color indicates the presence

    of Safrole or 1-phenyl-2-propaneone (BMK).

    If none of the above colors develop,the above list precursors are not present.

    The appearance of a red-brown color indicates the presence

    of 3,4-Methyleneedioxyphenyl-2 propanone (PMK, MDP2P).

    Procedure Card for IDT0270

    DRUG PRECURSOR TESTING KITS

    ReadBefore Use

    As a precaution, gloves and eye protection should be worn when handling drug substancesand using test units. Do not puncture any part of unit. Do not remove probe once a capsuleis broken. In the unlikely event of a spill, rinse affected area thoroughly with water.Keep out of reach of children. All results are presumptive. If necessary, further testingby a competent drug testing lab can provide additional identification.

    TM

    MDMA/METHAMPHETAMINE

    PRECURSORSSubstance Test

    Disposal After Dilution, the test kit is safe to dispose of in the trash.

    IIDDentaentaWorld Leader inForensic Products

    01-19

    Sample suspected substance.

    1 2

    Test

    Pre

    para

    tion

    Remove the Smart-Tip™ probe fromtest unit.

    Touch Smart-Tip™ probeto sample.Make surethe tip iscompletelycovered.

    Draw a sample using the pipette. Insert the tip ofthe pipette into the hole of thetest unit. Place2-3 drops intothe hole.

    LiquidPowder

    Manufactured by IDenta Ltdwww.identa-corp.comPatented Technology

    Made in Israel