Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Pro
Bar
®
ProBar ® Flowmeter
Product Data Sheet 00813-0100-4761; DS-4010
WHEN COMPARED WITH TRADITIONALDP FLOW MEASUREMENT, THEPROBAR FLOWMETER OFFERSGREATER VALUE AND PERFORMANCE
HIGH PERFORMANCE
• ±0.5% of rate reference accuracy
• 10:1 flow turndown
• Liquids
• Gases and steam (Consult Factory)
• 4—20mA and HART® flow outputs
REDUCED INSTALLATION COSTS
• Installation time reduced by 90%
• Fugitive emission points reduced by 80%
• NEW 2-line scalable display
REDUCED OPERATING COSTS
• Significantly lower pressure drop thanorifice or vortex meters
• Low operating costs
• Low maintenance costs
HIGH RELIABILITY
• ISO 9001 company
• NIST Traceable Calibration
COMPLETE POINT SOLUTIONS™
Complete Point Solutions provides fully engineered measurement solutions, combining best product and practices for improved performance, reliability, and cost of ownership.
The capability of the world’s finest industrial measurement instrumentation is further increased by combining it with a premier offering of complimentary products. This system is engineered and assembled by Rosemount Inc. to make it easy for you to specify and order the correct equipment for your process measurement needs.
We complement our field instruments with a wide range of technologies; including, manifolds, primary elements, process flanges and seals, and temperature sensors and accessories.
Complete Point Solutions is designed to provide you with Best-in-Class equipment — allowing you to save on installation costs, and improve the reliability and capability of your process.
Take advantage of our vast experience in process measurement, and start improving your process with Complete Point Solutions.
Flow-247
P R O B A R
Flow-248
ProBar ® Flowmeter
ProB
ar®
F L O W M E T E RPROBAR FLOWMETER- - - - - - - - - - - - - - - - - - - - - - - - - - 251REINVENTING DP FLOW MEASUREMENT- - - - - - - - - - - - - 251
Per formance
THE PROBAR FLOWMETER - - - - - - - - - - - - - - - - - - - - - - 252
Benef i ts
LOW INSTALLATION COSTS- - - - - - - - - - - - - - - - - - - - - - 254LOW OPERATING COSTS- - - - - - - - - - - - - - - - - - - - - - - - 255
Features
FEATURE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 256BENEFIT- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 256
Ins tal lat ion( Fo l low the PIPES Plan for Qua l i t y Ins tal lat ion .)
PIPE ORIENTATION - - - - - - - - - - - - - - - - - - - - - - - - - - - 257INSIDE PIPE DIAMETER (ID) - - - - - - - - - - - - - - - - - - - - - 257PIPE PENETRATION - - - - - - - - - - - - - - - - - - - - - - - - - - - 257ELECTRONICMOUNTING - - - - - - - - - - - - - - - - - - - - - - - 258STRAIGHT RUN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 258
Siz ing and How To Order
1. CHOOSE AMOUNTING METHOD- - - - - - - - - - - - - - - - - 2592. CHOOSE ASENSORSIZE - - - - - - - - - - - - - - - - - - - - - - 2603. VERIFY MODEL AND SENSORSIZE - - - - - - - - - - - - - - - 2614. CHOOSE THEMODEL OOPTIONS- - - - - - - - - - - - - - - - - 2635. VERIFY PROCESS ANDPIPE INFORMATION - - - - - - - - - - 264
P R O B A R
Rosemount Inc.
Pro
Bar
®
F L O W M E T E ROrdering In format ion— Model PBR
MODEL PBR+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - - 265MODEL PBR+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - - 267MODEL PBR+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - - 270MODEL PBR+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - - 273
Ordering In format ion— Model PBF
MODEL PBF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - - 281MODEL PBF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - - 284MODEL PBF+25H/26H - - - - - - - - - - - - - - - - - - - - - - - - 287MODEL PBF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - - 293MODEL PBF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - - 296MODEL PBF+45H/46H - - - - - - - - - - - - - - - - - - - - - - - - 299MODEL PBF+45M/46M - - - - - - - - - - - - - - - - - - - - - - - - 302
Ordering In format ion— Model PNT
MODEL PNT+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 310
Ordering In format ion— Model PNF
MODEL PNF+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 312MODEL PNF+10H- - - - - - - - - - - - - - - - - - - - - - - - - - - - 314MODEL PNF+10M - - - - - - - - - - - - - - - - - - - - - - - - - - - 316
Ordering In format ion— Model PNW
MODEL PNW+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - 318
Ordering In format ion— Model PHT
MODEL PHT+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 325MODEL PHT+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 328MODEL PHT+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 331
Ordering In format ion— Model PHF
MODEL PHF+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 340MODEL PHF+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 343MODEL PHF+25H- - - - - - - - - - - - - - - - - - - - - - - - - - - - 346MODEL PHF+25M - - - - - - - - - - - - - - - - - - - - - - - - - - - 349MODEL PHF+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 352MODEL PHF+45S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 355MODEL PHF+45H- - - - - - - - - - - - - - - - - - - - - - - - - - - - 358MODEL PHF+45M - - - - - - - - - - - - - - - - - - - - - - - - - - - 361
Spec i f ica t ions
FUNCTIONAL SPECIFICATIONS- - - - - - - - - - - - - - - - - - - - 371PERFORMANCESPECIFICATIONS- - - - - - - - - - - - - - - - - - - 372PHYSICAL SPECIFICATIONS- - - - - - - - - - - - - - - - - - - - - - 373SENSOR- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 373
Flow-249
Flow-250
ProBar ® Flowmeter
ProB
ar®
®
P R O B A R ®
F l o w m e t e r
Pro
Bar
®
Rosemount Inc.
PROBAR FLOWMETER
The ProBar flowmeter is a highly accurate insertion flowmeter. It measures volumetric flow rate for liquids, gases, and steam in line sizes from ½-inch to 72 inches. With fully integrated Rosemount® electronics and the Annubar® sensor, the ProBar flowmeter provides a ±0.5% of rate reference accuracy over a 10:1 flow turndown. By fully calibrating the integral ProBar flowmeter, Dieterich Standard, Inc. has eliminated the “percent of full scale” accuracy and turndown limitations associated with differential pressure (DP) technology.
Dieterich Standard, Inc. has joined with Rosemount Inc. to provide the latest technology in DP flow solutions. Rosemount Inc. is the technology leader in offering the highest performance and highest quality in DP transmitters. The 3051CD™ provides 0.075% accuracy, 100:1 rangeability, and the best stability of any industrial transmitter. In the years since its introduction, the 3051CD has become the new standard in DP sensing technology.
As a member of the Rosemount Inc. team, Dieterich Standard, Inc. combines 3051CD based electronics with the latest in DP primary technology— Diamond II+ Annubar primary flow element.
REINVENTING DPFLOW MEASUREMENTBy combining integrated electronics with insertion flowmeter technology, the ProBar flowmeter provides the lowest total cost of any precision flowmeter. Installation costs are reduced by insertion through a small tap into existing piping, and no plumbing is required between the electronics and the sensing element. Due to the aerodynamic shape of the sensing element, the ProBar flowmeter provides low operating costs. In addition, the sensor is insensitive to wrap, wear, and plugging. When compared with traditional DP flow measurement, the ProBar flowmeter offers greater value and performance. Together, Dieterich Standard, Inc. and Rosemount Inc. are reinventing DP flow measurement.
Flow-251
ProBar ® Flowmeter
Flow-2
ProB
ar®
Performance
THE PROBAR FLOWMETER
Reference Accuracy ± 0.5%and Turndown 10:1The ProBar flowmeter has better performance than vortex, insertion turbine, or DP flowmeters. Based on proven technology and NIST traceable calibration, the ProBar flowmeter is far superior to “percent of full scale” DP flowmeters.
FIGURE 1. Accuracy % Rate.
Sensor Design is Based on ProvenAnnubar Primary Flow Element Technology
The ProBar flowmeter is based on DP flow measurement technology. A DP is generated across the third generation Diamond II+ Annubar sensor. The linearity of the Diamond II+ is the key to the ProBar flowmeter’s accuracy and turndown capabilities. The DP signal generated is proportional to the flow rate in accordance with Bernoulli’s Theorem.
FIGURE 2. Bernoulli’s Theorem.
FIGURE 3. Diamond II+ Design.Diamond II+ design provides a fixed separation point
for linear, repeatable performance.
Compared to TraditionalDP Flow Measurement
When compared to traditional DP flow measurement, ProBar flowmeter improves the “percent of full scale” errors caused by the transmitter at high turndowns, and error caused by the primary element over the entire turndown. When comparing a ProBar flowmeter to an orifice plate and DP transmitter at a 10:1 flow turndown, the ProBar flowmeter maintains a ±0.5% reference accuracy while the errors caused by “percent of full scale” limitations of the transmitter can lead to a 5% inaccuracy.
FIGURE 4. ProBar DP Flow Measurement.
V12
2gc---------- P1
ρ-------+ V22
2gc---------- P2
ρ-------+=
25252
Rosemount Inc.
Pro
Bar
®
FIGURE 5. ProBar Flowmeter Diagram.
Patented Characterization Process
The ProBar flowmeter is calibrated over a wide turndown in a NIST traceable calibration flow laboratory. A characterization curve is formed and programmed into the electronics. The result is a linearized flowmeter that matches the actual volumetric flow rate with a +0.5% reference accuracy.
FIGURE 6. Patented Characterization Process.
The Probar Flowmeter Calibration Process
1. Reference flow is introduced to the ProBar flowmeter in a NIST traceable laboratory.
2. The ProBar flowmeter output is recorded over flow range.
3. Statistical regression analysis is used to arrive at the characterization curve.
4. The Characterization curve is programmed into the ProBar flowmeter electronics via patented process.
5. The ProBar flowmeter is tested a second time for verification of +0.5% of rate accuracy — a calibration test record is generated.
Test Data
The ProBar flowmeter calibration process provides an actual calibration test record that shows the ProBar flowmeter maintains +0.5% accuracy over a 10:1 flow turndown at reference conditions. Each ProBar flowmeter comes with a certified NIST traceable report that shows the results from the Dieterich Standard, Inc. flow laboratory.
FIGURE 7. Certified NIST Traceable Report.
PatentedPak-Lok ®
mountingfor safe
installationor optional
flangemounting
The sensor spans the entirepipe and senses the flowprofile. Calibrated in a NISTtraceable flow laboratory, ithas proven reliable inhundreds of thousandsof applications.
3
12
4
5
Cha racter iza tion Test
Veri f ication TestF low Turndown
Flow Turndown
Smart electronicslinearize theflowmeter over a wideflow turndown. WithProBar flowmeterelectronics, thespecifications can bemaintained for fiveyears with noadjustments. A4—20mA outputproportional to flowrate and HARTcommunicationsis standard.
Integratedmanifold forisolation andcalibration
Optional integralRTD (not shown)
Flow-253
ProBar ® Flowmeter
Flow-2
ProB
ar®
Benefits
LOW INSTALLATION COSTS
Compare ProBar Flowmeter Installation
The ProBar flowmeter offers low installation costs when compared to traditional DP flow measurement. The fully integrated electronics and sensor eliminate fittings, tubing, valves, manifolds, adapters, and mounting brackets and reduce welding and installation time.
See the ProBar flowmeter manual for the recommended installation of the ProBar flowmeter.
FIGURE 8. ProBar Flowmeter vs. Traditional DP.
TABLE 1. ProBar Flowmeter vs. Traditional DP.
Compare ProBar FlowmeterInstallation Costs
When compared to an orifice and vortex installation, the ProBar flowmeter saves installation and hardware costs while offering superior accuracy and turndown. The larger the line size, the more value the ProBar flowmeter offers.
FIGURE 9. Installation Cost Comparison.Ref: 6”SCH40, 100# Steam, 11,300PPH
Easy Plug-And-Play InstallationThe ProBar flowmeter provides the lowest cost installation of any precision flowmeter. The easy “plug-and-play” installation of the ProBar flowmeter includes four steps:
1. Drill a hole into the existing process piping.2. Weld a fitting onto the pipe.3. Insert the ProBar flowmeter.4. Wire to the DCS, recorder, or HART host.
FIGURE 10. Plug-and-Play Installation.
Traditional ProBar Flowmeter
16 Fittings & tubing 0
4 Valves 0
1 Manifold Integral
2 Adapter unions 0
1 Transmitter mountingbracket
0
50 linear inches Welding 4 linear inches
33 Leak points 6
Traditional DPInstallation
ProBar FlowmeterInstallation
ProBar Flowmeter
Vortex
Orifice
6 inch (150 mm) pipe,water 300# ANSI
Flowmeter or sensor
Mounting hardware
Transmitter
Manifold, valves & bracket
Weld (mounting)
Fittings & Tubing
Wiring
Start-up (Cal/Config)
25454
Rosemount Inc.
Pro
Bar
®
LOW OPERATING COSTS
Low Permanent Pressure Loss
The ProBar flowmeter has the lowest pressure drop and operating cost of any DP or vortex flowmeter. The aerodynamic shape of the ProBar flowmeter does not restrict the flow like the bluff body of a vortex shedder or the restrictive opening of an orifice plate.
FIGURE 11. Permanent Pressure Loss.Ref: 6”SCH40, 100# Steam, 11,300PPH
Energy Cost SavingPermanent pressure loss can be converted directly into energy costs in the form of compressor costs for gas, electrical costs for pumping liquids, and fuel costs for generating steam. Energy savings increase with line size and flow rate. The payback time for a ProBar flowmeter can be as short as six months in energy savings alone. Contact your local salesperson for a cost savings analysis of your application.
FIGURE 12. Energy Costs.Ref: 6”SCH40, 100# Steam, 11,300PPH
Low Maintenance Costs
The ProBar flowmeter sensor shape is designed to prevent wear and plugging that could affect calibration. The electronics are the most stable in the industry and will not drift outside of the total performance specification. Recalibration should not be required in a five-year period, providing significant savings in maintenance costs.
FIGURE 13. Non-plug design.
Reliability• ISO 9001 certified
• NIST traceable calibration
• Proven technology supplied by leading manufacturers
• 300 sales and service centers in 120 countries
• 90 years experience in flow measurement solutions
FIGURE 14. ProBar Flowmeter Reliability.
ÿþýüýýý
ÿüýýý
ÿþüýýý
ÿýý
ÿý
ÿþý
8”(200mm)
12”(300mm)
14”(400mm)
4”(100mm)
ProBar Flowmeter
Vortex
Orifice
ÿþý
ÿþ
ý þ
þ
Flow-255
ProBar® Flowmeter
Flow-2
ProB
ar®
Features
FEATURE BENEFIT
Integral RTDA three wire 100 Ω platinum RTD is inserted into a sealed, pressure retaining thermowell in the sensor. Connections are made through an explosion-proof junction box.
Designs by other vendors that do not provide a sealed thermowell are a potential hazard when removal of the RTD is required. The integral RTD eliminates hardware and installation costs.
A single pipe penetration allows measurement of mass flow, including temperature.
FIGURE 15. Integral RTD.
Pak-Lok ® MountingPak-Lok mounting seals and secures the ProBar flowmeter firmly against the inside opposite wall simply and without high torque requirements. This design safely retains the sensor under high process pressures. It also provides additional structural support by placing the sensor in compression.
Allows safe and simple installation of ProBar flowmeter.
FIGURE 16. Pak-Lok Mounting.
Flanged Pipe SectionA good installation of the sensor is assured with the flanged pipe section option. The pipe can be made to any length for easy replacement of other piping components.
The ProBar flowmeter can be mounted in a flanged pipe section for easy installation between existing flanges.
FIGURE 17. Flanged Pipe Section.
Direct Mount Integral ManifoldThe ProBar flowmeter electronics can be mounted directly to the sensor by means of either a 3- or 5-valve manifold. Upwards of 28 potential leak paths can be eliminated. The integral mount can be used in all fluids except where the temperature exceeds 500 °F (260 °C).
Allows the electronics to be mounted directly to the sensor, eliminating costs and leak paths. FIGURE 18. Direct Mount
Integral Manifold.
Elbow MountProBar flowmeter can be installed two pipe diameters from the centerline of an elbow and still provide good accuracy and repeatability: +3% without calibration.
ProBar flowmeter can achieve good accuracy two pipe diameters from an elbow.
FIGURE 19. Elbow Mount.
Flo-Tap ProBar FlowmeterFlo-Tap ProBar flowmeter is perfectly suited to retrofit applications because the Flo-Tap can be hot-tapped without interruption of the flow, and without system shutdown.
Allows insertion and retraction without system shutdown.
FIGURE 20. Bi-directionalFlow Measurement.
Bi-directional Flow MeasurementThe symmetrical design, along with the controlled separation point provided by the exclusive diamond–shaped sensor means a single ProBar flowmeter is all that is required for bi-directional flow measurement.
A single ProBar flowmeter can provide accurate bi–directional flow measurement.
Integrated Electronics Mounting
56
Rosemount Inc.
Pro
Bar
®
Installation (Follow the PIPES Plan for Quality Installation.)
The performance of any flow measurement device depends greatly upon the quality of the installation. This is also true for ProBar flowmeter. Studies have shown that greater than 70% of flow measurement problems are traceable to installation error. Installation of ProBar flowmeter is very simple, but attention must be paid to simple principles. These principles are common to all DP devices and most flowmeters in general. The Dieterich Standard, Inc. acronym for these principles is “PIPES”:
Pipe orientation
Inside diameter
Pipe penetration
Electronics mounting
Straight run
PIPE ORIENTATION
The sensor must be installed in the proper orientation relative to the pipe and the fluid measured. This must be specified at the time of order placement. For gases, the electronics must be mounted above the pipe. For liquid and steam, the electronics must be mounted below the pipe. See the I/O manual for detailed installation instructions.
FIGURE 21. Pipe Orientation.
INSIDE PIPE DIAMETER (ID)
It is important to use the exact pipe ID in ProBar flowmeter installations to avoid flow measurement errors. Throat diameter is a squared factor for DP flow measurement devices. With the ProBar flowmeter, the pipe itself forms the throat. Using the pipe as the throat of the meter reduces permanent pressure loss and the effect of wear on the throat.
FIGURE 22. Pipe ID.
PIPE PENETRATION
The sensor mounting hole must be smooth and the correct size to avoid disturbing the flow profile. Drilling is the only acceptable method to properly prepare the mounting hole. See hole size recommendations in the manual 00809-0100-4761.
FIGURE 23. Sensor Mounting Hole.
ÿþý
þý þý
þýþý
PreferredLocationMounting
Liquid or Steam InstallationGas Installation
Flow CD2
DP=
257Flow-257
Flow-2
ProBar® Flowmeter
ProB
ar®
ELECTRONIC MOUNTING
Mounting of the electronics can be either integral or remote. Integral is preferred because of simplified installation, fewer leak points, faster response, and greater accuracy. Remote mounting is required when the process temperature exceeds 500 °F (260 °C) or when there is excessive vibration. Where remote mounting of the electronics is required, it is important that the orientation of the electronics relative to the sensor is correct. For gases, the electronics must be above the sensor and for liquids, below the sensor. It is critical to review the I/O manual on this topic and on commissioning.
FIGURE 24. Electronic Mounting.
STRAIGHT RUN
To obtain published accuracy, sufficient straight run is required to produce a fully developed flow profile. Shorter lengths are possible, but accuracy will be affected. See Table 2 for recommended straight run requirements for the ProBar flowmeter.
Straight run requirements are also more stringent for achieving the highest accuracy. The recommended values shown are upstream straight run requirements. Four diameters are required downstream.
TABLE 2. Upstream Straight Run Requirements.
Remote MountingIntegral Mounting
Location With Vanes Without Vanes
After an elbow 8 10
Two elbows out of plane 8 28
After a modulating control valve 8 30
After an expansion 8 18
After a constriction 8 12
58
Rosemount Inc.
Flow-259
Pro
Bar
®
Sizing and How To Order
1. CHOOSE A MOUNTING METHOD
PBR
FIGURE 25. Regular ThreadedPak–Lok Assembly.
Mounting MethodThreaded Pak–Lok.Pipe Sizes2 in. to 72 in.(50 mm to 1800 mm).
PBF
FIGURE 26. Flanged.
Mounting MethodFlanged.Pipe Sizes2 in. to 72 in. (50 mm to 1800 mm).
PHF
FIGURE 27. High PressureFlanged Flo–Tap.
Mounting MethodFlanged Flo–Tap for pressure equivalent to ANSI Class 600 Flanges.Pipe Sizes2 in. to 72 in. (50 mm to 1800 mm).
PHT
FIGURE 28. High PressureThreaded Flo-Tap.
Mounting MethodThreaded Flo-Tap for pressure equivalent to ANSI Class 600 Flanges.Pipe Sizes2 in. to 72 in. (50 mm to 1800 mm).
PNF
FIGURE 29. Flanged In–Line.
Mounting MethodFlanged In–Line.Pipe Sizes½ in. to 2 in. (25 mm to 50 mm).
PNT
FIGURE 30. Threaded In-Line.
Mounting MethodThreaded In–Line.Pipe Sizes½ in. to 2 in. (25 mm to 50 mm).
PNW
FIGURE 31. Butt Weld In-Line.
Mounting MethodButt Weld In–Line.Pipe Sizes½ in. to 2 in. (25 mm to 50 mm).
Flow-260
ProBar ® Flowmeter
ProB
ar®
2. CHOOSE A SENSOR SIZE
The following table is a guideline for selecting the correct sensor.
TABLE 3. Sensors and Pipe Sizes.
Conversions for Verifications of Flowsfor Fluids Other Than Air and Water
1. To convert GPM of water to GPM of any other fluid, divide the maximum GPM by the square root of the specific gravity of the liquid.
2. To convert SCFM of air to SCFM of any other gas, divide the max SCFM by the square root of the specific gravity of the other gas.
3. To convert standard flow rates to actual flow rates (gas):
4. To convert volume flow to mass flow:
5. To convert U.S. to metric units:
Sensor Pipe Sizes
10 - PNT, PNW & PNF ½ in. to 2 in.(DIN 15-DIN 50)
15/16 2 in. to 5 in.(DIN 50-DIN 125)
25/26 4 in. to 42 in.(DIN 100-DIN 1000)
35/36 10 in. to 72 in.(DIN 200 to DIN 1800)
45/46 16 in. to 72 in.(DIN 250 to DIN 1800)
GPMotherGPMwater
SGother--------------------------------=
SCFMotherSCFMair
SGother-----------------------------=
35.302Pf
Tf 460+( )---------------------------× xACFM
ACFMTf 460°F+( )
Pf 35.302×( )----------------------------------- SCFM××
Pf = Flowing pressure (psia)Tf = Flowing temperature (°F)
PPMGPM DensityofLiquid lb ft
3⁄( )×7.48
----------------------------------------------------------------------------------------------=
PPM ACFM DensityofGas×=
LPM GPM 3.78533×=
lb hr⁄ 2.205× kg hr⁄=
NM3
H SCFH35.37------------------=
Rosemount Inc.
Flow-261
Pro
Bar
®
3. VERIFY MODEL & SENSOR SIZE
Compare the maximum allowable flow below to your maximum flow rates.
hw = maximum differential pressure in inches of water column. ½ in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute 30 in. to 42 in. Sch Std.
GPM = maximum water flow in gallons per minute 48 in. to 72 in. Actual I.D.
At standard conditions: Air — 60 °F at 14.73 psia
Water — 60 °F, specific gravity 1.0, viscosity 1.12 centipoise
Nom.pipe
size (ininches)
Sensor 10
PNT PNF PNW
SCFM hw GPM SCFM hw GPM SCFM hw GPM
.5 180.52 1500 50.943 180.52 1500 50.943 180.52 1500 50.943
.75 307.79 1500 89.404 307.79 1500 89.404 307.79 1500 89.404
1 498.82 1500 144.9 498.82 1500 144.9 498.82 1500 144.9
1.25 765.68 1180 222.41 765.68 1180 222.41 765.68 1180 222.41
1.5 902.04 884 262.02 902.04 884 262.02 902.04 884 262.02
2 1174.9 552 341.28 1174.9 552 341.28 1174.9 552 341.28
Sensor 15 Sensor 16
PBR PBF PHF PBR PBF
SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
2 1236.1 611 359.05 502.91 84.3 133.37 1555 967 451.7 1236.1 611 359.05 1322 699 384.04
2.5 1531.9 451 440.14 639.74 66.9 169.52 1886.4 699 547.95 1531.9 451 440.14 1641 529 476.68
3 2010.5 314 567.07 859.71 50.5 227.41 2408.7 478 699.65 2010.5 314 567.07 2175.3 380 623.82
3.5 2408.7 246 671.26 1046.1 41.7 276.37 2852.6 369 822.13 2408.7 246 671.26 2639.5 305 747.44
4 2816 199 777.38 1237.1 35.1 326.48 3331.3 294 944.89 2816 199 777.33 3126.9 253 876.53
5 3723.8 137 1013.6 1663.7 25.6 438.17 4364.9 195 1209.3 3723.8 137 1013.6 4213.3 180 1161.9
Sensor 25 Sensor 26
PBR PBF PHF PBR PBF
SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
4 6263.45 1090 1819.4 2827.2 189 757.59 7347.5 1500 2134.3 6263.4 1090 1819.4 7047.5 1380 2047.1
5 8148.5 747 2366.9 3798.1 138 1017.3 10066 1140 2924 8148.5 747 2366.9 9366.4 987 2720.7
6 10088 549 2930.2 4839.5 107 1293.6 12299 816 3572.4 10088 549 2930.2 11783 749 3422.6
8 14100 346 4028.2 6867.4 71.2 1827.3 16486 489 4788.8 14100 346 4029.2 16570 494 4813.2
10 18737 235 5232.7 9125.3 50.2 2418.5 21270 318 6087.1 18737 235 5232.7 22053 348 6367.7
12 23218 174 6391.4 11299 38 2986.8 26142 228 7316.3 23218 174 6391.4 27773 263 7857.8
14 25971 147 7099.9 12665 32.6 3343.5 29131 190 8071.7 25971 147 7099.9 31411 226 8803.3
16 30390 116 8238.9 14829 26.1 3908.1 33874 147 9274.7 30390 116 8238.9 37265 182 10320
18 34880 94.2 9397.7 17017 21.4 4479.2 38584 117 10473 34880 94.2 9397.7 43086 149 11819
20 39558 77.7 10608 19311 17.8 5077.3 43384 94.5 11699 39558 77.7 10608 49210 124 13401
24 48768 55.7 12990 23901 13 6275.5 52897 66 14140 48768 55.7 12990 61463 90.6 16567
30 65577 35.6 17355 32211 8.43 8445.5 70325 41.1 18648 65577 35.6 17355 83933 59.3 22399
36 80406 25.2 21207 39598 6.03 10374 85555 28.6 22592 80406 25.2 21207 103900 42.6 27573
42 95305 18.8 25083 47023 4.53 12313 100650 21 26510 95305 18.8 25083 123750 32 32725
ProBar ® Flowmeter
Flow-262
ProB
ar®
hw= maximum differential pressure in inches of water column. ½ in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute 30 in. to 42 in. Sch Std.
GPM = maximum water flow in gallons per minute 48 in. to 72 in. Actual I.D.
At standard conditions: Air — 60 °F at 14.73 psia
Water — 60 °F, specific gravity 1.0, viscosity 1.12 centipoise
Nom.pipe
size (ininches)
Sensor 35 Sensor 36
PBR PBF PHF PBR PBF
SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
8 20661 768 6001.4 9950.2 153 2678.7 24501 1080 7116.8 20661 768 6001.4 24387 1070 7083.8
10 26823 521 7791.3 13239 108 3547.4 31224 706 9069.8 26823 521 7791.3 32204 751 9351.3
12 32883 385 9507.2 16469 82.3 4395.6 37485 505 10088 32833 385 9507.2 39824 570 11568
14 37058 327 10589 18488 70.7 4923.8 41364 421 12015 37058 327 10589 44625 490 12962
16 43668 258 12287 21590 56.7 5760.1 48040 325 13791 43668 258 12287 52273 394 15184
18 50338 209 13998 24947 46.6 6609.8 55095 258 15553 50338 209 13998 60481 324 17429
20 57299 172 15783 28344 38.8 7496.1 62559 210 17439 57299 172 15783 69596 270 19774
24 71017 123 19303 36548 28.3 9259.1 76801 146 21031 71017 123 19303 87990 198 24491
30 96282 78.9 25837 47441 18.4 12477 103040 91.1 27763 96282 78.9 25837 121480 130 33165
36 118650 56 31613 58452 13.2 15348 125830 63.3 33611 118650 56 31613 151120 93.2 40783
42 141020 41.8 37402 69564 9.95 18248 148640 46.6 39491 141020 41.8 37402 181070 70.3 48505
48 163400 32.4 43205 80662 7.76 21144 171330 35.7 45353 163400 32.4 43205 211020 54.9 56240
60 208140 21.1 54825 102920 5.1 26954 216230 22.8 56991 206140 21.1 54825 270800 36.1 71712
72 253470 14.9 66623 125280 3.61 32793 261750 15.9 68822 253470 14.9 66623 330970 25.6 87327
Sensor 45 Sensor 46
PBR PBF PHF PBR PBF
SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
10 41878 1270 12165 20133 256 5461.5 45513 1500 13220 41878 1270 12165 45513 1500 13220
12 51142 940 14855 24994 195 6766.1 59210 1260 17199 51142 940 14855 61288 1350 17803
14 56913 797 16532 28092 168 7590.1 65325 1050 18975 56913 797 16532 68661 1160 19944
16 66100 630 19200 33012 135 8888.1 74858 808 21744 66100 630 19200 80698 939 23441
18 75353 511 21888 38019 111 10201 84461 642 24539 75353 511 21888 92738 774 26938
20 85108 422 24722 43418 93.2 11618 94565 521 27469 85108 422 24722 105460 648 30634
24 106480 303 30297 53975 68.2 14374 114620 364 33207 106480 303 30291 130590 475 37933
30 146170 194 40515 73415 44.7 19448 156190 226 43729 146170 194 40515 178800 313 51462
36 181760 138 49627 90648 32.1 23938 192700 157 52933 181760 138 49627 226020 226 63508
42 217210 103 58712 108240 24.3 28517 229510 116 62307 217210 103 58712 273660 171 75649
48 251110 78.8 67379 125770 19 33086 265390 88.6 71446 251110 78.8 67379 321370 134 87865
60 321930 51.5 85653 160730 12.5 42190 337470 56.8 89952 321930 51.5 85653 416410 88.4 112220
72 392880 36.3 103990 195900 8.86 51374 408770 39.4 108340 392800 36.3 103990 511830 62.8 136780
Rosemount Inc.
Flow-263
Pro
Bar
®
4. CHOOSE THE MODEL OPTIONS
Model Numbers Description Page Numbers
PBR+15/16S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 265
PBR+25/26S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 267
PBR+35/36S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 270
PBR+45/46S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 273
PBF+15/16S ProBar® + Flowmeter—Flanged, SST page 281
PBF+25/26S ProBar® + Flowmeter—Flanged, SST page 284
PBF+25/26H ProBar® + Flowmeter—Flanged, Hastelloy–C page 287
PBF+25/26M ProBar® + Flowmeter—Flanged, Monel page 290
PBF+35/36S ProBar® + Flowmeter—Flanged, SST page 293
PBF+45/46S ProBar® + Flowmeter—Flanged, SST page 296
PBF+45/46H ProBar® + Flowmeter—Flanged, Hastelloy–C page 299
PBF+45/46M ProBar® + Flowmeter—Flanged, Monel page 302
Line Sizes—2 in. and larger
PNT+10S ProBar® + Flowmeter—In-Line Threaded, SST page 310
PNF+10S ProBar® + Flowmeter—In-Line Flanged, SST page 312
PNF+10H ProBar® + Flowmeter—In-Line Flanged, Hastelloy-C page 314
PNF+10M ProBar® + Flowmeter—In-Line Flanged, Monel page 316
PNW+10S ProBar® + Flowmeter—In-Line Butt Weld, SST page 318
Line Sizes—½ in. to 2 in.
PHT+15S ProBar® + Flowmeter—Threaded Flo-Tap, SST page 325
PHT+25S ProBar® + Flowmeter—Threaded Flo-Tap, SST page 328
PHT+35S ProBar® + Flowmeter—Threaded Flo-Tap, SST page 331
PHF+15S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 340
PHF+25S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 343
PHF+25M ProBar® + Flowmeter—Flanged Flo-Tap, Monel page 349
PHF+35S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 352
PHF+45S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 355
PHF+45H ProBar® + Flowmeter—Flanged Flo-Tap, Hastelloy-C page 358
PHF+45M ProBar® + Flowmeter—Flanged Flo-Tap, Monel page 361
Flow-264
ProBar ® Flowmeter
ProB
ar®
5. VERIFY PROCESS AND PIPE INFORMATION
Configuration InformationWhen ordering a ProBar, it is important to include all of the flowing conditions and pipe information for your application. This will ensure that you receive the correct product for your application. Please see the ProBar Configuration Data Sheet 00806–0100–4761.
Dimension CodesCertain dimensions are critical to the fabrication of the primary flow element assembly. The following codes can be specified in the model callout “string” and Dieterich Standard, Inc. will build the primary flow element assembly to suit. If no dimension is specified, cataloged components will default to standard dimensions.
ODH
ODH is the outside diameter of the pipe to the top of the ProBar head (Figure 25). If this dimension is specified for a flanged, Flo–Tap, or Regular model, the neck of the primary flow element just below standard dimension can be considered a minimum. This dimension does not apply to in–line sensors or to Model 45S.
FIGURE 25. ODH.
ODF
ODF is the outside diameter of the pipe to the face of the mounting flange (Figure 26). This dimension applies only to DFF, DHF, DSF, NFF, SPF, SFF, and SSF models. If Dieterich Standard, Inc. is not supplying the mounting hardware, this dimension must be specified. If Dieterich Standard, Inc. is providing the mounting flange assembly, note the following:
• The standard ODF is a minimum.
• The extensions must be at least 2 inches longer than the minimum ODF.
FIGURE 26. ODF.
ODV
ODV is the outside diameter of the pipe to the top of the isolation valve (Figure 27). ODV applies to Flo–Tap models only, and only when the customer supplies some or all of the mounting hardware.
FIGURE 27. ODV.
NL
NL is the nipple length for DNW, DNF, and DNT-10 in-line models (Figure 28). Additional length can be specified to fit specific piping configurations. The extra length will be applied upstream of the sensor unless otherwise specified.
FIGURE 28. NL.
CMH
CMH is the customer mount height distance from the outside of the pipe to the top of the appropriately sized NPT threaded female mounting coupling (Figure 29). Supply these values for Regular and Flo–Tap models that are being installed in a customer’s mounting or saddle.
FIGURE 29. CMH.
ODH
ODF
ODV
CMH
Rosemount Inc.
Pro
Bar
®
Ordering Information—Model PBRMODEL PBR+15S/16S
Model Product Description
PBR+15SPBR+16S
ProBar® + Flowmeter - RegularProBar® + Flowmeter - Regular with Opposite SIde Support
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple,1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow,1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple,1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Port, SST
Code Mounting Hardware
MP2C0MP2S0MR2C0MR2S0
Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, CSPak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, SSTPak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, CSPak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Flow-265
Flow-2
ProBar ® Flowmeter
ProB
ar®
66
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum 1/2—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G1/2
Code Opposite Side Support (Required for Model 16S ONLY)
MS2C0MS2CWMS2S0MS2SW
Contoured Weld Fitting and Plug, 1/2—14 NPT, CSContoured Weld Fitting and Plug, 1/2 in. Socket Weld Port, CSContoured Weld Fitting and Plug, 1/2—14 NPT, SSTContoured Weld Fitting and Plug, 1/2 in. Socket Weld Port, SST
Code Optional Auxiliary Mounting (Mounting Alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT2CMT2SME2CME2AME2KME2PME2SNB20NC20ND20NE20NF20
Contoured Weld Fitting, 1/2—14 NPT, CSContoured Weld Fitting, 1/2—14 NPT, SSTWeld Coupling, 1/2—14 NPT, CSWeld Coupling, 1/2—14 NPT, AluminumWeld Coupling, 1/2—14 NPT, CopperWeld Coupling, 1/2—14 NPT, PVCWeld Coupling, 1/2—14 NPT, SSTSaddle, Double Strap, 2.35-2.56, 1/2—14 NPT, IronSaddle, Double Strap, 2.41-2.91,1/2—14 NPT, IronSaddle, Double Strap, 2.97-3.54,1/2—14 NPT, IronSaddle, Double Strap, 4.14-4.80,1/2—14 NPT, IronSaddle, Double Strap, 5.94-6.70,1/2—14 NPT, Iron
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
LMZ
Multipoint Flow Calibration (ID <= 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBR+15S 020 HA2S0 CA2C0 MP2C0 1 A 1 A
MODEL PBR+15S/16S
Pro
Bar
®
Rosemount Inc.
MODEL PBR+25S/26SModel Product Description
PBR+25SPBR+26S
ProBar® + Flowmeter - RegularProBar® + Flowmeter - Regular with Opposite Side Support
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATS0HATSBHATSDHATSN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD,B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVDS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line,1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line,1/2 in. Socket Weld Port, SSTParallel, Vertical Line,1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee,1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Port, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle valve, Nipple,1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Flow-267
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Instrument Connections (Continued)
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Code Mounting Hardware
MR4C0MR4S0MP4C0MP4S0
Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, CSPak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, SSTPak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum 1/2—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G1/2
Code Opposite Side Support (Required for Model 26S ONLY)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1in. Socket Weld Port, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1in. Socket Weld Port, SST
Code Optional Auxiliary Mounting (Mounting Alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT4CMT4SME4CME4AME4KME4PME4SNE40NF40NG40NH40NJ40
Contoured Weld Fitting, 1—11.5 NPT, CSContoured Weld Fitting, 1—11.5 NPT, SSTWeld Coupling, 1—11.5 NPT, CSWeld Coupling, 1—11.5 NPT, AluminumWeld Coupling, 1—11.5 NPT, CopperWeld Coupling, 1—11.5 NPT, PVCWeld Coupling, 1—11.5 NPT, SSTSaddle, Double Strap, 3.74-4.55OD, 1—11.5 NPT, IronSaddle, Double Strap, 5.94-6.7in.OD,1—11.5 NPT, IronSaddle, Double Strap, 8.54-10.1OD,1—11.5 NPT, IronSaddle, Double Strap, 10.64-12.12,1—11.5 NPT, IronSaddle, Double Strap, 12.6-14.3OD,1—11.5 NPT, Iron
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2in. Pipe/Panel, SST Bolts
MODEL PBR+25S/26S
68
Rosemount Inc.
Pro
Bar
®
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBR+25S 040 HAMS0 C0000 MP4C0 1 A 1 A
MODEL PBR+25S/26S
Flow-269
Flow-2
ProBar ® Flowmeter
ProB
ar®
MODEL PBR+35S/36SModel Product Description
PBR+35SPBR+36S
ProBar® + Flowmeter - RegularProBar® + Flowmeter - Regular with Opposite Side Support
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1,Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATS0HATSBHATSDHATSN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD,B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, with 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line,1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
70
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam,1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Code Mounting Hardware
MP6C0MP6S0MR6C0MR6S0
Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, SSTPak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, CSPak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum 1/2-14Epoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G1/2
Code Opposite Side Support (Required for Model 36S ONLY)
MS6C0MS6CWMS6S0MS6SW
Contoured Weld Fitting and Plug, 11/2—11.5 NPT, CSContoured Weld Fitting and Plug, 11/2 in. Socket Weld Port, CSContoured Weld Fitting and Plug, 11/2—11.5 NPT, SSTContoured Weld Fitting and Plug, 11/2 in. Socket Weld Port, SST
Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT6CMT6S
Contoured Weld Fitting,11/2—11.5 NPT, CSContoured Weld Fitting,11/2—11.5 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
MODEL PBR+35S/36S
Flow-271
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBR+35S 120 HAMS0 C0000 MP6C0 1 A 1 A
MODEL PBR+35S/36S
72
Rosemount Inc.
Pro
Bar
®
MODEL PBR+45S/46SModel Product Descriptions
PBR+45SPBR+46S
ProBar® + Flowmeter-RegularProBar® + Flowmeter-Regular with Opposite Side Support
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATS0HATSBHATSDHATSN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0HVDSNHVMS0HVPS0HVTSB
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, with 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line,1/2 in. Socket Weld Port, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line,1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0CP2SSSP2S0SP2SS
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2SSCC2S0CC2SSSC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Flow-273
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Mounting Hardware
MPDC0MPDS0
Pak-Lok, with Contoured Weld Fitting, 3—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 3—11.5 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum 1/2—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G1/2
Code Opposite Side Support (Required for Model 46S ONLY)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in. BW, CSContoured Weld Fitting and Cap, 3 in. BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
MODEL PBR+45S/46S
74
Rosemount Inc.
Pro
Bar
®
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBR+45S 240 HAMS0 C0000 MPDC0 1 A 1 A
MODEL PBR+45S/46S
Flow-275
ProBar ® Flowmeter
Flow-
ProB
ar®
276276
Rosemount Inc.
Pro
Bar
®
Flow-277
ProBar ® Flowmeter
Flow-
ProB
ar®
278278
Rosemount Inc.
Pro
Bar
®
Flow-279
ProBar ® Flowmeter
Flow-
ProB
ar®
280280
Rosemount Inc.
Pro
Bar
®
Ordering Information—Model PBFMODEL PBF+15S/16S
Model Product Description
PBF+15SPBF+16S
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in., Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in., Socket Weld Port, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in., Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in., Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0CP2SSSP2S0SP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in., Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in., Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in., Socket Weld Port, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CB2SSCC2S0CC2SSSC2S0SV2S0SV2SSCB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Sensor Flange
FNMS0FLMS0FJMS0FC4S0FB4S0FA4S0
DIN 25 PN 100, 316 SSTDIN 25 PN 40, 316 SSTDIN 25 PN 16, 316 SST1 in. ANSI Class 600, RF, SST1 in. ANSI Class 300, RF, SST1 in. ANSI Class 150, RF, SST
Flow-281
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Flanged Mount
FA4CFA4SFB4CFB4SFC4CFC4SFJMCFJMSFLMCFLMSFNMCFNMS
1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SSTDIN 25 PN 16, CSDIN 25 PN 16, 316 SSTDIN 25 PN 40, CSDIN 25 PN 40, 316 SSTDIN 25 PN 100, CSDIN 25 PN 100, 316 SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABC
Epoxy-Poly-Aluminum 1/2—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5
Code Housing Material
DJKLM
Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Aluminum G1/2
Code Opposite Side Support (Required for Model 16S ONLY)
MS2C0MS2CWMS2S0MS2SW
Contoured Weld Fitting and Plug, 1/2—14 NPT, CSContoured Weld Fitting and Plug, 1/2 in., Socket Weld Port, CSContoured Weld Fitting and Plug, 1/2—14 NPT, SSTContoured Weld Fitting and Plug, 1/2 in., Socket Weld Port, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–Proof
Code Optional Manifolds
356781
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SSTCoplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
Code Optional Calibration
LMZ
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special Calibration
MODEL PBF+15S/16S
82
Rosemount Inc.
Pro
Bar
®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QM8QT1QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)EN 10204 3.1B Material CertsHydrostatic Test EP-4017Extended Hydro EP-4046
Typical Model Number PBF+15S 020 HAMS0 C0000 FA4S0 FA4C 1 A 1 A
MODEL PBF+15S/16S
Flow-283
Flow-2
ProBar ® Flowmeter
ProB
ar®
MODEL PBF+25S/26SModel Product Description
PBF+25SPBF+26S
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0HAXS0
Direct and Integral Mount HeadsDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATS0HATSBHATSDHATSN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in., Socket Weld Port, SSTParallel, Horizontal Line,1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in., Socket Weld Port, SST
HPVS0HPVSSHV2S0HV2SS
Parallel, Vertical Line,1/2 in., Socket Weld Port, SSTParallel, Vertical Line,1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in., Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple,1/2—14 NPT, CSNeedle Valve, Nipple and Tee,1/2—14 NPT, CSNeedle Valve, Elbow, 1/2— 14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0CP2SSSP2S0SP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in., Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in., Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in., Socket Weld Port, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
84
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CB2SSCC2S0CC2SSSC2S0SV2S0SV2SSCB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Sensor Flange
FNPS0FLPS0FJPS0FC6S0FB6S0FA6S0
DIN 40 PN 100, 316 SSTDIN 40 PN 40, 316 SSTDIN 40 PN 16, 316 SST11/2 in. ANSI Class 600, RF, SST11/2 in. ANSI Class 300, RF, SST11/2 in. ANSI Class 150, RF, SST
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFJPCFJPSFLPCFLPSFNPCFNPS
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SSTDIN 40 PN 16, CSDIN 40 PN 16, 316 SSTDIN 40 PN 40, CSDIN 40 PN 40, 316 SSTDIN 40 PN 100, CSDIN 40 PN 100, 316 SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum 1/2—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G1/2
Code Opposite Side Support (Required for Model 26S ONLY)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in., Socket Weld Port, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
MODEL PBF+25S/26S
Flow-285
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QM8QT1QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)EN 10204 3.1B Material CertsHydrostatic Test EP-4017Extended Hydro EP-4046
Typical Model Number PBF+25S 040 HAMS0 C0000 FA6S0 FA6C 1 A 1 A
MODEL PBF+25S/26S
86
Rosemount Inc.
Pro
Bar
®
MODEL PBF+25H/26HCode Product Description
PBF+25HPBF+26H
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADH0HADHBHADHNHAMH0HAPH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, with 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-C
HATH0HATHBHATHDHATHN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C
HVDH0HVDHBHVDHNHVMH0HVPH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CIntegral, with 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-C
HVTH0HVTHBHVTHDHVTHN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
HA2H0HA2HSHP2H0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-CAxial, Horizontal Line, 1/2 in., Socket Weld Port, Hastelloy-CParallel, Horizontal Line,1/2—14 NPT, Hastelloy-C
HPVH0HV2H0
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0SP2S0CA2S0SA2S0
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CA2H0CP2H0
Needle Valve - HastelloyNeedle Valve, Elbow, 1/2—14 NPT, Hastelloy-CNeedle Valve, Nipple, 1/2—14 NPT, Hastelloy-C
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 11/2—14 NPT, CSOutside Stem and Yoke Gate, Vertical Line, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Flow-287
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Instrument Connections (Continued)
CC2S0SC2S0SV2S0CB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Sensor Flange
FC6H0FB6H0FA6H0
11/2 in. ANSI Class 600, RF, Hastelloy-C11/2 in. ANSI Class 300, RF, Hastelloy-C11/2 in. ANSI Class 150, RF, Hastelloy-C
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0 -.5 to 0 - 25 inH20 (0-.12 to 0-6.22 kPa)0 - 2.5 to 0 - 250 inH20 (0 -.62 to 0 - 62.2 kPa)0 - 10 to 0 - 830 inH20 (0 - 2.48 to 0 - 206 kPa)
Code Output
A 4— 20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum 1/2—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G1/2
Code Opposite Side Support (Required for Model 26H ONLY)
MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
MODEL PBF+25H/26H
88
Rosemount Inc.
Pro
Bar
®
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBF+25H 040 HAMH0 C0000 FA6H0 FA6C 1 A 1 A
MODEL PBF+25H/26H
Flow-289
Flow-2
ProBar ® Flowmeter
ProB
ar®
MODEL PBF+25M/26MModel Product Description
PBF+25MPBF+26M
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADM0HADMBHADMNHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1,Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HATM0HATMBHATMDHATMN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount,5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDM0HVDMBHVDMNHVMM0HVPM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1,Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HVTM0HVTMBHVTMDHVTMN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD,B31.1,Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0HA2MSHP2M0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, MonelAxial, Horizontal Line, ½ in., Socket Weld Port, MonelParallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0HV2M0HV2MS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, ½ in., Socket Weld Port, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0SP2S0CA2S0SA2S0
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2M0CA2M0
Needle Valve - MonelNeedle Valve, Nipple, 1/2—14 NPT, MonelNeedle Valve, Elbow, 1/2—14 NPT, Monel
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Yoke, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
90
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CC2S0SC2S0SV2S0CB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Sensor Flange
FC6M0FB6M0FA6M0
1½ in. ANSI Class 600, RF, Monel1½ in. ANSI Class 300, RF, Monel1½ in. ANSI Class 150, RF, Monel
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6S
1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0 -.5 to 0 - 25 inH20 (0 -.12 to 0 - 6.22 kPa)0 - 2.5 to 0 - 250 inH20 (0 -.62 to 0 - 62.2kPa)0 - 10 to 0 - 830 inH20 (0 - 2.48 to 0 - 206kPa)
Code Output
A 4–20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G½316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Opposite Side Support (Required for Model 26M ONLY)
MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
MODEL PBF+25M/26M
Flow-291
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material - Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBF+25M 040 HAMM0 C0000 FA6M0 FA6C 1 A 1 A
MODEL PBF+25M/26M
92
Rosemount Inc.
Pro
Bar
®
MODEL PBF+35S/36SModel Product Description
PBF+35SPBF+36S
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0HAXS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATS0HATSBHATSDHATSN
Direct and Integral Mount Heads - Horizontal Line With RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line With RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, ½ in., Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, ½ in., Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, ½ in., Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, ½ in., Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CA2S0SA2S0CP2SSSP2SS
Needle Valve - SSTNeedle Valve, Elbow, ½ in., Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple, ½ in., Socket Weld Port, SSTNeedle Valve, Nipple and Tee, ½ in., Socket Weld Port, SST
SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Flow-293
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Instrument Connections (Continued)
SC2S0SV2S0CB2S0SB2S0CB2SSCC2SSSV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in., Socket Weld Port, SST
Code Sensor Flanges
FNRS0FLRS0FJRS0FC8S0FB8S0FA8S0
DIN 50 PN 100, 316 SSTDIN 50 PN 40, 316 SSTDIN 50 PN 16, 316 SST2 in. ANSI Class 600, RF, SST2 in. ANSI Class 300, RF, SST2 in. ANSI Class 150, RF, SST
Code Flanged Mount
FA8CFA8SFB8CFB8SFC8CFC8SFJRCFJRSFLRCFLRSFNRCFNRS
2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SSTDIN 50 PN 16, CSDIN 50 PN 16, 316 SSTDIN 50 PN 40, CSDIN 50 PN 40, 316 SSTDIN 50 PN 100, CSDIN 50 PN 100, 316 SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Opposite Side Support (Required for Model 36S ONLY)
MS6C0MS6CWMS6S0MS6SW
Contoured Weld Fitting and Plug, 1½—11.5 NPT, CSContoured Weld Fitting and Plug, 1½ in., Socket Weld Port, CSContoured Weld Fitting and Plug, 1½—11.5 NPT, SSTContoured Weld Fitting and Plug, 1½ in., Socket Weld Port, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
356781
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SSTCoplanar Bracket, 2 in., Pipe/Panel, SST Bolts
MODEL PBF+35S/36S
94
Rosemount Inc.
Pro
Bar
®
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBF+35S 120 HAMS0 C0000 FA8S0 FA8C 1 A 1 A
MODEL PBF+35S/36S
Flow-295
Flow-2
ProBar ® Flowmeter
ProB
ar®
MODEL PBF+45S/46SModel Product Description
PBF+45SPBF+46S
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0HAXS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATS0HATSBHATSDHATSN
Direct and Integral Mount Heads - Horizontal Line With RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line With RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0HSHS0
Remote Mount - Horizontal LineParallel, Horizontal Line, ½ in., Socket Weld Port, SSTAxial, Horizontal Line, ½ in.—14 NPT, SSTAxial, Horizontal Line, ½ in., Socket Weld Port, SST
Parallel, Horizontal Line,½ in.—14 NPT, SSTStack Head with Purge, Horizontal Line, ½ in.—14 NPT, SST
HPVS0HPVSSHV2S0HV2SSHSVS0
Parallel, Vertical Line, ½ in., Socket Weld Port, SSTParallel, Vertical Line, ½ —14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in., Socket Weld Port, SSTStack Head with Purge, Vertical Line, ½—14 NPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SS
Needle Valve - SSTNeedle Valve, Elbow, ½ in., Socket Weld Port, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in., Socket Weld Port, SSTNeedle Valve, Nipple and Tee, ½ in., Socket Weld Port, SST
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
96
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in., Socket Weld Port, SST
Code Sensor Flanges
FBDS0FNTS0FLTS0FJTS0FCDS0FADS0
3 in. ANSI Class 300, RF, SSTDIN 80 PN 100, 316 SSTDIN 80 PN 40, 316 SSTDIN 80 PN 16, 316 SST3 in. ANSI Class 600, RF, SST3 in. ANSI Class 150, RF, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDSFJTCFJTSFLTCFLTSFNTCFNTS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SSTDIN 80 PN 16, CSDIN 80 PN 16, 316 SSTDIN 80 PN 40, CSDIN 80 PN 40, 316 SSTDIN 80 PN 100, CSDIN 80 PN 100, 316 SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Opposite Side Support (Required for Model 46S ONLY)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
MODEL PBF+45S/46S
Flow-297
Flow-2
ProBar ® Flowmeter
ProB
ar®
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBF+45S 240 HAMS0 C0000 FADS0 FADC 1 A 1 A
MODEL PBF+45S/46S
98
Rosemount Inc.
Pro
Bar
®
MODEL PBF+45H/46HModel Product Description
PBF+45HPBF+46H
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADH0HADHBHADHNHAMH0HAPH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, with 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-C
HATH0HATHBHATHDHATHN
Direct and Integral Mount Heads - Horizontal Line With RTDIntegral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold,RTD,B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C
HVDH0HVDHBHVDHNHVMH0HVPH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CIntegral, with 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-C
HVTH0HVTHBHVTHDHVTHN
Direct and Integral Mount Heads - Vertical Line With RTDIntegral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, B31.1,Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
HA2H0HA2HSHP2H0
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, Horizontal Line, ½ in., Socket Weld Port, Hastelloy-CParallel, Horizontal Line, ½—14 NPT, Hastelloy-C
HPVH0HV2H0HSVH0
Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, Hastelloy-C.Axial, Vertical Line, ½—14 NPT, Hastelloy-C.Stack head with purge, Vertical Line, ½—14 NPT, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0SP2S0
Needle Valve - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
CP2H0Needle Valve - HastelloyNeedle Valve, Nipple, ½—14 NPT, Hastelloy-C
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, ½—14 NPT½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code Sensor Flanges
FCDH0FBDH0FADH0
3 in. ANSI Class 600, RF, Hastelloy-C3 in. ANSI Class 300, RF, Hastelloy-C3 in. ANSI Class 150, RF, Hastelloy-C
Flow-299
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Opposite Side Support (Required for Model 46H ONLY)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
MODEL PBF+45H/46H
00
Rosemount Inc.
Pro
Bar
®
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBF+45H 240 HAMH0 C0000 FADH0 FADC 1 A 1 A
MODEL PBF+45H/46H
Flow-301
Flow-3
ProBar ® Flowmeter
ProB
ar®
MODEL PBF+45M/46MModel Product Description
PBF+45MPBF+46M
ProBar® + Flowmeter - FlangedProBar® + Flowmeter - Flanged with Opposite Side Support
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADM0HADMBHADMNHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HATM0HATMBHATMDHATMN
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDM0HVDMBHVDMNHVMM0HVPM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HVTM0HVTMBHVTMDHVTMN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0HA2MSHP2M0
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in., Socket Weld Port, MonelParallel, Horizontal Line, ½—14 NPT, Monel
HPVM0HV2M0HV2MSHSVM0
Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½ in., Socket Weld Port, MonelStack Head with Purge, Vertical Line, ½—14 NPT, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0SP2S0
Needle Valve - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
CP2M0Needle Valve - MonelNeedle Valve, Nipple, ½—14 NPT, Monel
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate, Vertical Line, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate, Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code Sensor Flanges
FCDM0FBDM0FADM0
3 in. ANSI Class 600, RF, Monel3 in. ANSI Class 300, RF, Monel3 in. ANSI Class 150, RF, Monel
02
Rosemount Inc.
Pro
Bar
®
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Opposite Side Support (Required for Model 46M ONLY)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion–ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion–Proof, AxialIntegral RTD, Explosion–Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion–Proof and Intrinsic Safety ApprovalFM Explosion–Proof ApprovalFM Explosion–Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion–Proof Approval
MODEL PBF+45M/46M
Flow-303
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Optional Calibration
LMZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in. to 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Multipoint Flow Calibration (18 in. to 20 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA2Q21Q23Q29QJ2QM2QT2QT8
Certified ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PBF+45M 240 HAMM0 C0000 FADM0 FADC 1 A 1 A
MODEL PBF+45M/46M
04
Rosemount Inc.
Pro
Bar
®
Flow-305
ProBar ® Flowmeter
Flow-
ProB
ar®
306306
Rosemount Inc.
Pro
Bar
®
Flow-307
ProBar ® Flowmeter
Flow-
ProB
ar®
308308
Rosemount Inc.
Pro
Bar
®
Flow-309
ProBar ® Flowmeter
Flow-3
Ordering
Ordering Information—Model PNTMODEL PNT+10S
Model Product Description
PNT+10S ProBar® + Flowmeter - In-line Threaded
Code Line Size
005007010012015020
½ in. (12.5 mm)¾ in. (19 mm)1 in. (25 mm)1¼ in. (31 mm)1½ in. (37.5 mm)2 in. (50 mm)
Code Fittings
HAMS0HADS0HADSBHADSNHAPS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HVMS0HVDS0HVDSBHVDSNHVPS0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HF1SSHM1S0
Remote MountFittings, ¼ in. Socket Weld Ports, SSTFittings, ¼—18 NPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0SP1C0
Needle Valve - CSNeedle Valve, Nipple, ¼—18 NPT, CSNeedle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0SP1S0
Needle Valve - SSTNeedle Valve, Nipple, ¼—18 NPT, SSTNeedle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0SB1S0
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal Based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG 13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
10
Rosemount Inc.
Pro
Bar
®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety CertificateKEMA/CENELEC Explosion-Proof Approval
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PNT+10S 010 HAMS0 C0000 1 A 1 A
MODEL PNT+10S
Flow-311
Flow-3
ProBar ® Flowmeter
ProB
ar®
Ordering Information—Model PNFMODEL PNF+10S
Model Product Description
PNF+10S ProBar® + Flowmeter - In-line Flanged
Code Line Size
005007010012015020
½ in. (12.5 mm)¾ in. (19 mm)1 in. (25 mm)1¼ in. (31 mm)1½ in. (37.5 mm)2 in. (50 mm)
Code Fittings
HAMS0HADS0HADSBHADSNHAPS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HVMS0HVDS0HVDSBHVDSNHVPS0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HF1SSHM1S0
Remote MountFittings, ¼ in. Socket Weld Ports, SSTFittings, ¼—18 NPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0SP1C0
Needle Valve - CSNeedle Valve, Nipple, ¼—18 NPT, CSNeedle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0SP1S0
Needle Valve - SSTNeedle Valve, Nipple, ¼—18 NPT, SSTNeedle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0SB1S0
Gate ValveOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code Flanged Mount
FASFBSFCSFJSFLSFNS
ANSI Class 150, Weld-Neck RF, SSTANSI Class 300, Weld-Neck RF, SSTANSI Class 600, Weld-Neck RF, SSTDIN PN 16, SSTDIN PN 40, SSTDIN PN 100, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal Based on HART
Code Fill Fluid
12
SiliconeInert Fill
12
Rosemount Inc.
Pro
Bar
®
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG 13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety CertificateKEMA/CENELEC Explosion-Proof Approval
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PNF+10S 010 HAMS0 C0000 FAS 1 A 1 A
MODEL PNF+10S
Flow-313
Flow-3
ProBar ® Flowmeter
ProB
ar®
MODEL PNF+10HModel Product Description
PNF+10H ProBar® + Flowmeter - In-line Flanged
Code Line Size
005007010012015020
½ in. (12.5 mm)¾ in. (19 mm)1 in. (25 mm)1¼ in. (31 mm)1½ in. (37.5 mm)2 in. (50 mm)
Code Fittings
HADH0HADHNHAMH0HAPH0HADHB
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
HVDH0HVDHNHVMH0HVPH0HVDHB
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
HM1H0Remote MountFittings, ¼—18 NPT, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0SP1C0
Needle Valve - CSNeedle Valve, Nipple, ¼—18 NPT, CSNeedle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0SP1S0
Needle Valve - SSTNeedle Valve, Nipple, ¼—18 NPT, SSTNeedle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0SB1S0
Gate ValveOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code Flanged Mount
FAHFBHFCH
ANSI Class 150, Weld-Neck RF, Hastelloy-CANSI Class 300, Weld-Neck RF, Hastelloy-CANSI Class 600, Weld-Neck RF, Hastelloy-C
Code DP Ranges
123
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 in H2O (0-.62 to 0-62.2 kPa)0-10 to 0-830 in H2O (0-2.48 to 0-206 kPa)
Code Output
A 4–20 mA with Digital Signal Based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG 13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
14
Rosemount Inc.
Pro
Bar
®
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety CertificateKEMA/CENELEC Explosion-Proof Approval
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PNF+10H 010 HAMH0 C0000 FAH 1 A 1 A
MODEL PNF+10H
Flow-315
Flow-3
ProBar ® Flowmeter
ProB
ar®
MODEL PNF+10MModel Product Description
PNF+10M ProBar® + Flowmeter - In-line Flanged
Code Line Size
005007010012015020
½ in. (12.5 mm)¾ in. (19 mm)1 in. (25 mm)1¼ in. (31 mm)1½ in. (37.5 mm)2 in. (50 mm)
Code Fittings
HADMNHADM0HADMBHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HVDMNHVDM0HVDMBHVMM0HVPM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HM1M0Remote MountFittings, ¼—18 NPT, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0SP1C0
Needle Valve - CSNeedle Valve, Nipple, ¼—18 NPT, CSNeedle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0SP1S0
Needle Valve - SSTNeedle Valve, Nipple, ¼—18 NPT, SSTNeedle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0SB1S0
Gate ValveOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code Flanged Mount
FAMFBMFCM
ANSI Class 150, Weld-Neck RF, MonelANSI Class 300, Weld-Neck RF, MonelANSI Class 600, Weld-Neck RF, Monel
Code DP Ranges
123
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 in H2O (0-.62 to 0-62.2 kPa)0-10 to 0-830 in H2O (0-2.48 to 0-206 kPa)
Code Output
A 4–20 mA with Digital Signal Based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG 13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
16
Rosemount Inc.
Pro
Bar
®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety CertificateKEMA/CENELEC Explosion-Proof Approval
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PNF+10M 010 HAMM0 C0000 FAM 1 A 1 A
MODEL PNF+10M
Flow-317
Flow-3
ProBar ® Flowmeter
ProB
ar®
Ordering Information—Model PNWMODEL PNW+10S
Model Product Description
PNW+10S ProBar® + Flowmeter - In-line Butt Weld
Code Line Size
005007010012015020
½ in. (12.5 mm)¾ in. (19 mm)1 in. (25 mm)1¼ in. (31 mm)1½ in. (37.5 mm)2 in. (50 mm)
Code Fittings
HAMS0HADS0HADSBHADSNHAPS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HVMS0HVDS0HVDSBHVDSNHVPS0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HF1SSHM1S0
Remote MountFittings, ¼ in. Socket Weld Ports, SSTFittings, ¼—18 NPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0SP1C0
Needle Valve - CSNeedle Valve, Nipple, ¼—18 NPT, CSNeedle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0SP1S0
Needle Valve - SSTNeedle Valve, Nipple, ¼—18 NPT, SSTNeedle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0SB1S0
Gate ValveOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4–20 mA with Digital Signal Based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly-Aluminum ½—14 NPTEpoxy-Poly-Aluminum CM 20Epoxy-Poly-Aluminum PG 13.5Epoxy-Poly-Aluminum G½316 SST ½—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly-Aluminum G½
18
Rosemount Inc.
Pro
Bar
®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5-Valve Manifold, CS5-Valve Manifold, SST3-Valve Manifold, CS3-Valve Manifold, SST
Code Optional Mounting Brackets
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate) - Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety CertificateKEMA/CENELEC Explosion-Proof Approval
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number PNW+10S 010 HAMS0 C0000 1 A 1 A
MODEL PNW+10S
Flow-319
ProBar ® Flowmeter
Flow-
ProB
ar®
320320
Rosemount Inc.
Pro
Bar
®
Flow-321
ProBar ® Flowmeter
Flow-
ProB
ar®
322322
Rosemount Inc.
Pro
Bar
®
Flow-323
ProBar ® Flowmeter
Flow-
ProB
ar®
324324
Rosemount Inc.
Pro
Bar
®
Ordering Information—Model PHTMODEL PHT+15S
Model Product Description
PHT+15S ProBar® + Flowmeter - Threaded Flo-Tap
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HVMS0HVDS0HVDSBHVDSNHVPS0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, 1/2 in. Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SSCB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Packing Gland
GV3S0GV3C0GH3S0GH3C0
Graphite, 3/4—14 NPT, SSTGraphite, 3/4—14 NPT, CSUrethane, 3/4—14 NPT, SSTUrethane, 3/4—14 NPT, CS
Flow-325
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Insert/Retract
IHRSIHRC
Manual, Dual, SST RodsManual, Dual, CS Rods
Code Isolation Valve
VT3SGVT3CG
Gate ValveGate Valve, 3/4—14 NPT, SSTGate Valve, 3/4—14 NPT, CS
VT3SBVT3CB
Ball ValveBall Valve, 3/4—14 NPT, SSTBall Valve, 3/4—14 NPT, CS
Code Mounting Hardware
MH3C0MH3S0
Weld Coupling and Nipple, 3/4—14 NPT, CSWeld Coupling and Nipple, 3/4—14 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
LMZ
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special Calibration
MODEL PHT+15S
26
Rosemount Inc.
Pro
Bar
®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHT+15S 020 HAMS0 C0000 GV3S0 IHRC VT3CG MH3C0 2 A 1 A
MODEL PHT+15S
Flow-327
Flow-3
ProBar ® Flowmeter
ProB
ar®
MODEL PHT+25SModel Product Description
PHT+25S ProBar® + Flowmeter - Threaded Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATSNHATS0HATSDHATSB
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, SST
HVMS0HVDS0HVDSBHVDSNHVPS0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, 1/2 in. Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
28
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SSCB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Packing Gland
GV5S0GV5C0GH5S0GH5C0
Graphite, 11/4—11.5 NPT, SSTGraphite, 11/4—11.5 NPT, CSUrethane, 11/4—11.5 NPT, SSTUrethane, 11/4—11.5 NPT, CS
Code Insert/Retract
IHRSIHRCIHDS
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST Rods
Code Isolation Valve
VT5SGVT5CG
Gate ValveGate Valve, 11/4—11.5 NPT, SSTGate Valve, 11/4—11.5 NPT, CS
VT5SBVT5CB
Ball ValveBall Valve, 11/4—11.5 NPT, SSTBall Valve, 11/4—11.5 NPT, CS
Code Mounting Hardware
MH5C0MH5S0
Weld Coupling and Nipple, 11/4—11.5 NPT, CSWeld Coupling and Nipple, 11/4—11.5 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
MODEL PHT+25S
Flow-329
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Optional Manifolds
356789
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SSTSpecial Manifold
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHT+25S 040 HAMS0 C0000 GV5SO IHRC VT5CG MH5C0 2 A 1 A
MODEL PHT+25S
30
Rosemount Inc.
Pro
Bar
®
MODEL PHT+35SModel Product Description
PHT+35S ProBar® + Flowmeter - Threaded Flo-Tap
Code Line Size
100120140160180200240300340360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)34 in. (864 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. (1520 mm)72 in. (1820 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATSNHATS0HATSDHATSB
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, SST
HVMS0HVDS0HVDSBHVDSNHVPS0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, 1/2 in. Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
Flow-331
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Instrument Connections (Continued)
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SSCB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Packing Gland
GV8S0GV8C0GH8S0GH8C0
Graphite, 2—11.5 NPT, SSTGraphite, 2—11.5 NPT, CSUrethane, 2—11.5 NPT, SSTUrethane, 2—11.5 NPT, CS
Code Insert/Retract
IHRSIHRCI990IHDS
Manual, Dual, SST RodsManual, Dual, CS RodsSpecial Insert/Retract AssemblyGear, Dual, SST Rods
Code Isolation Valves
VT8SGVT8CG
Gate ValveGate Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CS
VT8SBVT8CB
Ball ValveBall Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, CS
Code Mounting Hardware
MH8C0MH8S0
Weld Coupling and Nipple, 2—11.5 NPT, CSWeld Coupling and Nipple, 2—11.5 NPT, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
MODEL PHT+35S
32
Rosemount Inc.
Pro
Bar
®
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHT+35S 120 HAMS0 C0000 GV8C0 IHDS VT8CG MH8C0 2 A 1 A
MODEL PHT+35S
Flow-333
ProBar ® Flowmeter
Flow-
ProB
ar®
334334
Rosemount Inc.
Pro
Bar
®
Flow-335
ProBar ® Flowmeter
Flow-
ProB
ar®
336336
Rosemount Inc.
Pro
Bar
®
Flow-337
ProBar ® Flowmeter
Flow-
ProB
ar®
338338
Rosemount Inc.
Pro
Bar
®
Flow-339
Flow-3
ProBar ® Flowmeter
ProB
ar®
Ordering Information—Model PHFMODEL PHF+15S
Model Product Description
PHF+15S ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Head Mount - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Head Mount - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, 1/2 in. Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections)
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SSCB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
40
Rosemount Inc.
Pro
Bar
®
Code Packing Gland
GV4SCGV4SBGV4SAGH4SCGH4SBGH4SA
Graphite, 1 in. ANSI Class 600, SSTGraphite, 1 in. ANSI Class 300, SSTGraphite, 1 in. ANSI Class 150, SSTUrethane, 1 in. ANSI Class 600, SSTUrethane, 1 in. ANSI Class 300, SSTUrethane, 1 in. ANSI Class 150, SST
Code Insert/Retract
IHRSIHRC
Manual, Dual, SST RodsManual, Dual, CS Rods
Code Isolation Valve
VC4SGVC4CGVB4SGVB4CGVA4SGVA4CG
Gate ValveGate Valve, 1 in. ANSI Class 600, SSTGate Valve, 1 in. ANSI Class 600, CSGate Valve, 1 in. ANSI Class 300, SSTGate Valve, 1 in. ANSI Class 300, CSGate Valve, 1 in. ANSI Class 150, SSTGate Valve, 1 in. ANSI Class 150, CS
VB4SBVB4CBVA4SBVA4CB
Ball ValveBall Valve, 1 in. ANSI Class 300, SSTBall Valve, 1 in. ANSI Class 300, CSBall Valve, 1 in. ANSI Class 150, SSTBall Valve, 1 in. ANSI Class 150, CS
FA4CFA4SFB4CFB4SFC4CFC4S
Other1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-Proof
Code Optional Manifolds
356789
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SSTSpecial Manifold
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
MODEL PHF+15S
Flow-341
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
LMZ
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+15S 020 HAMS0 C0000 GV4SA IHRS VA4CG 1 A 1 A
MODEL PHF+15S
42
Rosemount Inc.
Pro
Bar
®
MODEL PHF+25SModel Product Description
PHF+25S ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)5 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATSNHATS0HATSD
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, 1/2 in. Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CA2S0SA2S0CP2SSSP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Flow-343
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Instrument Connections (Continued)
CC2S0SC2S0SV2S0CB2S0SB2S0CB2SSCC2SSSV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Code Packing Gland
GV8SCGV8SBGV8SAGH8SCGH8SBGH8SA
Graphite, 2 in. ANSI Class 600Graphite, 2 in. ANSI Class 300Graphite, 2 in. ANSI Class 150Urethane, 2 in. ANSI Class 600, SSTUrethane, 2 in. ANSI Class 300, SSTUrethane, 2 in. ANSI Class 150, SST
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VB8SGVB8CGVA8SGVA8CG
Gate ValveGate Valve, 2 in. ANSI Class 300, SSTGate Valve, 2 in. ANSI Class 300, CSGate Valve, 2 in. ANSI Class 150, SSTGate Valve, 2 in. ANSI Class 150, CS
VB8SBVB8CBVA8SBVA8CB
Ball ValveBall Valve, 2 in. ANSI Class 300, SSTBall Valve, 2 in. ANSI Class 300, CSBall Valve, 2 in. ANSI Class 150, SSTBall Valve, 2 in. ANSI Class 150, CS
Code Flanged Mount
FA8CFA8SFB8CFB8SFC8CFC8S
2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
MODEL PHF+25S
44
Rosemount Inc.
Pro
Bar
®
Code Optional Manifolds
356789
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SSTSpecial Manifold
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+25S 080 HADSO C0000 GV8SA IHRC VA8SG FA87C 2 A 1 A
MODEL PHF+25S
Flow-345
Flow-3
ProBar ® Flowmeter
ProB
ar®
MODEL PHF+25HModel Product Description
PHF+25H ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADH0HADHBHADHNHAMH0HAPH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C.Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C.Direct Mount, No Manifold, Horizontal Line, Hastelloy-C.
HATH0HATHBHATHDHATHN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C.
HVDH0HVDHBHVDHNHVMH0HVPH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C.Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C.Direct Mount, No Manifold, Vertical Line, Hastelloy-C.
HVTH0HVTHBHVTHDHVTHN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C.
HA2H0HA2HSHP2H0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-C.Axial, Horizontal Line, 1/2 in. Socket Weld Port, Hastelloy-C.Parallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HPVH0HV2H0
Remote Mount - Horizontal LineParallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0SP2S0CA2S0SA2S0
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CA2H0CP2H0
Needle Valve - HastelloyNeedle Valve, Elbow, 1/2—14 NPT, Hastelloy-C.Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C.
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
46
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CC2S0SC2S0SV2S0CB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Packing Gland
GV6HCGV6HBGV6HA
Graphite, 11/2 in.ANSI Class 600, Hastelloy-C.Graphite, 11/2 in.ANSI Class 300, Hastelloy-C.Graphite, 11/2 in.ANSI Class 150, Hastelloy-C.
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VC6SGVC6CGVB6SGVB6CGVA6SGVA6CG
Gate ValveGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 11/2 in. ANSI Class 150, SSTGate Valve, 11/2 in. ANSI Class 150, CS
VB6SBVB6CBVA6SBVA6CB
Ball ValveBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, SSTBall Valve, 11/2 in. ANSI Class 150, CS
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
MODEL PHF+25H
Flow-347
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+25H 040 HAMH0 C0000 GV6HA IHRC VA6CG FA6C 1 A 1 A
MODEL PHF+25H
48
Rosemount Inc.
Pro
Bar
®
MODEL PHF+25MModel Product Description
PHF+25M ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADH0HADM0HADMBHADMNHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HATM0HATMBHATMDHATMN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDH0HVDM0HVDMBHVDMNHVMM0HVPM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HVTM0HVTMBHVTMDHVTMN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0HA2MSHP2M0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, MonelAxial, Horizontal Line, 1/2 in. Socket Weld Port, MonelParallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0HV2M0HV2MS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2 in. Socket Weld Port, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0SP2S0CA2S0SA2S0
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2M0CA2M0
Needle Valve - MonelNeedle Valve, Nipple, 1/2—14 NPT, MonelNeedle Valve, Elbow, 1/2—14 NPT, Monel
Flow-349
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Instrument Connections (Continued)
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2S0SB2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code Packing Gland
GV6MCGV6MBGV6MA
Graphite, 11/2 in. ANSI Class 600, MonelGraphite, 11/2 in. ANSI Class 300, MonelGraphite, 11/2 in. ANSI Class 150, Monel
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VC6SGVC6CGVB6SGVB6CGVA6SGVA6CG
Gate ValveGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 11/2 in. ANSI Class 150, SSTGate Valve, 11/2 in. ANSI Class 150, CS
VB6SBVB6CBVA6SBVA6CB
Ball ValveBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, SSTBall Valve, 11/2 in. ANSI Class 150, CS
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
MODEL PHF+25M
50
Rosemount Inc.
Pro
Bar
®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+25M 040 HAMM0 C0000 GV6MA IHRC VA6CG FA6C 1 A 1 A
MODEL PHF+25M
Flow-351
Flow-3
ProBar ® Flowmeter
ProB
ar®
MODEL PHF+35SModel Product Description
PHF+35S ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATSNHATS0HATSD
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVMS0HVPS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SSHA2S0HA2SSHP2S0
Remote Mount - Horizontal LineParallel, Horizontal Line, 1/2 in. Socket Weld Port, SSTAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Port, SSTParallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Port, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CA2S0SA2S0CP2SSSP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
52
Rosemount Inc.
Pro
Bar
®
Code Instrument Connections (Continued)
CC2C0SC2C0SV2C0CB2C0SB2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2S0SB2S0CB2SSCC2SSSV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Code Packing Gland
GV8SCGV8SBGV8SAGH8SCGH8SBGH8SA
Graphite, 2 in. ANSI Class 600Graphite, 2 in. ANSI Class 300Graphite, 2 in. ANSI Class 150Urethane, 2 in. ANSI Class 600, SSTUrethane, 2 in. ANSI Class 300, SSTUrethane, 2 in. ANSI Class 150, SST
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VB8SGVB8CGVA8SGVA8CG
Gate ValveGate Valve, 2 in. ANSI Class 300, SSTGate Valve, 2 in. ANSI Class 300, CSGate Valve, 2 in. ANSI Class 150, SSTGate Valve, 2 in. ANSI Class 150, CS
VB8SBVB8CBVA8SBVA8CB
Ball ValveBall Valve, 2 in. ANSI Class 300, SSTBall Valve, 2 in. ANSI Class 300, CSBall Valve, 2 in. ANSI Class 150, SSTBall Valve, 2 in. ANSI Class 150, CS
Code Flanged Mount
FA8CFA8SFB8CFB8SFC8CFC8S
2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
MODEL PHF+35S
Flow-353
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
356789
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SSTSpecial Manifold
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+35S 120 HAMS0 C0000 GV8SA IHDC VA8C 1 A 1 A
MODEL PHF+35S
54
Rosemount Inc.
Pro
Bar
®
MODEL PHF+45SModel Product Description
PHF+45S ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0HAXS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-valve Manifold, Horizontal Line, SST
HATSNHATS0HATSD
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HVDSBHVDSNHVMS0HVPS0HVTS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0SP2S0CP2SSSP2SS
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Port, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Code Packing Gland
GVDSCGVDSBGVDSA
Graphite, 3 in. ANSI Class 600Graphite, 3 in. ANSI Class 300Graphite, 3 in. ANSI Class 150
Flow-355
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VCDSGVCDCGVBDSGVBDCGVADCGVADSG
Gate ValveGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CSGate Valve, 3 in. ANSI Class 150, SST
VBDSBVBDCBVADCBVADSB
Ball ValveBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CSBall Valve, 3 in. ANSI Class 150, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
0123
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
356789
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SSTSpecial Manifold
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
MODEL PHF+45S
56
Rosemount Inc.
Pro
Bar
®
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+45S 240 HAMS0 C0000 GVDSA IHDS VADCG FADC 1 A 1 A
MODEL PHF+45S
Flow-357
Flow-3
ProBar ® Flowmeter
ProB
ar®
58
MODEL PHF+45HModel Product Description
PHF+45H ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADH0HADHBHADHNHAMH0HAPH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C.Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C.Direct Mount, No Manifold, Horizontal Line, Hastelloy-C.
HATH0HATHBHATHDHATHN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C.
HVDH0HVDHBHVDHNHVMH0HVPH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C.Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C.Direct Mount, No Manifold, Vertical Line, Hastelloy-C.
HVTH0HVTHBHVTHDHVTHN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C.Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C.
HA2H0HA2HSHP2H0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-C.Axial, Horizontal Line, 1/2 in. Socket Weld Port, Hastelloy-C.Parallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HPVH0HV2H0
Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0SP2S0
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2H0Needle Valve - HastelloyNeedle Valve, Nipple, 1/2—14 NPT, Hastelloy-C.
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Code Packing Gland
GVDHCGVDHBGVDHA
Graphite, 3 in. ANSI Class 600, Hastelloy-C.Graphite, 3 in. ANSI Class 300, Hastelloy-C.Graphite, 3 in. ANSI Class 150, Hastelloy-C.
Rosemount Inc.
Pro
Bar
®
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VCDSGVCDCGVBDSGVBDCGVADCGVADSG
Gate ValveGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CSGate Valve, 3 in. ANSI Class 150, SST
VBDSBVBDCBVADCBVADSB
Ball ValveBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CSBall Valve, 3 in. ANSI Class 150, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
MODEL PHF+45H
Flow-359
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+45H 240 HAMS0 C0000 GVDHA IHDC VADCG FADC 1 A 1 A
MODEL PHF+45H
60
Rosemount Inc.
Pro
Bar
®
MODEL PHF+45MModel Product Description
PHF+45M ProBar® + Flowmeter - Flanged Flo-Tap
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADM0HADMBHADMNHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, 5-Valve Manifold, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HATM0HATMBHATMDHATMN
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDM0HVDMBHVDMNHVMM0HVPM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HVTM0HVTMBHVTMDHVTMN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0HA2MSHP2M0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, MonelAxial, Horizontal Line, 1/2 in. Socket Weld Port, MonelParallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0HV2M0HV2MS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2 in. Socket Weld Port, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0SP2S0
Needle Valve - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2M0Needle Valve - MonelNeedle Valve, Nipple, 1/2—14 NPT, Monel
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Flow-361
Flow-3
ProBar ® Flowmeter
ProB
ar®
Code Packing Gland
GVDMCGVDMBGVDMA
Graphite, 3 in. ANSI Class 600, MonelGraphite, 3 in. ANSI Class 300, MonelGraphite, 3 in. ANSI Class 150, Monel
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VCDSGVCDCGVBDSGVBDCGVADCGVADSG
Gate ValveGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CSGate Valve, 3 in. ANSI Class 150, SST
VBDSBVBDCBVADCBVADSB
Ball ValveBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CSBall Valve, 3 in. ANSI Class 150, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code DP Ranges
123
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Code Output
A 4—20 mA with Digital Signal based on HART
Code Fill Fluid
12
SiliconeInert Fill
Code Housing Material
ABCDJKLM
Epoxy-Poly.-Alum. 1/2—14 NPTEpoxy-Poly.-Alum. CM20Epoxy-Poly.-Alum. PG13.5Epoxy-Poly.-Alum. G1/2316 SST 1/2—14 NPT316 SST CM 20316 SST PG 13.5Epoxy-Poly.-Alum. G1/2
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion-Proof, AxialIntegral RTD, Explosion-Proof, Parallel
Code Optional Manifolds
35678
Model 305 Manifold Bolted to Transmitter5 Valve Manifold, CS5 Valve Manifold, SST3 Valve Manifold, CS3 Valve Manifold, SST
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
MODEL PHF+45M
62
Rosemount Inc.
Pro
Bar
®
Code Optional Meters
124
LCD Meter (Rate)- Aluminum HousingLCD Meter (Rate) - SST HousingExternal LCD Rate and Total Display
Code Optional Hazardous Location Certificates
I5C6E5K5IDED
FM Intrinsic Safety ApprovalCSA Explosion-Proof and Intrinsic Safety ApprovalFM Explosion-Proof ApprovalFM Explosion-Proof and Intrinsic Safety ApprovalKEMA/CENELEC Intrinsic Safety ApprovalKEMA/CENELEC Explosion-Proof Approval
Code Optional Calibration
MLZNPOQRSTUVWXY
Multipoint Flow Calibration (ID ≤ 10 in.)Lab Flow Calibration (Average K) (<10 in.)Special CalibrationMultipoint Flow Calibration (12 in.)Multipoint Flow Calibration (14 in., 16 in.)Lab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in.-16 in.)Multipoint Flow Calibration (18 in., 20 in.)Lab Flow Calibration (Average K) (18 in.-20 in.)Multipoint Flow Calibration (24 in.)Lab Flow Calibration (Average K) (24 in.)Multipoint Flow Calibration (30 in.)Lab Flow Calibration (Average K) (30 in.)Multipoint Flow Calibration (36 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: PHF+45M 240 HAMM0 C0000 GVDMA IHDC VADCG FADC 1 A 1 A
MODEL PHF+45M
Flow-363
ProBar ® Flowmeter
Flow-
ProB
ar®
364364
Rosemount Inc.
Pro
Bar
®
Flow-365
ProBar ® Flowmeter
Flow-
ProB
ar®
366366
Rosemount Inc.
Pro
Bar
®
Flow-367
ProBar ® Flowmeter
Flow-
ProB
ar®
368368
Rosemount Inc.
Pro
Bar
®
Flow-369
Flow-3
ProBar ® Flowmeter
ProB
ar®
70
Rosemount Inc.
-371
Pro
Bar
®
Specifications
371Flow
FUNCTIONAL SPECIFICATIONS
Service (1)
Liquid, gas, or steam.
Pipe Sizes (2)
1/2 in. to 72 in. (12 mm to 1800 mm).
Ranges (3)
Range 0: 0-0.6 in. to 0-3 in. H20(0-0.15 to 0-7.5 kPa).
Range 1: 0-0.5 in. to 0-25 in. H20(0-0.12 to 0-7.22 kPa).
Range 2: 0-2.5 in. to 0-250 in. H20(0-0.62 to 0-62.2 kPa).
Range 3: 0-10 in. to 0-1000 in. H20(0-2.48 to 0-248 kPa).
Indication
Optional two-line, scalable digital LCD meter.
Output4-20mADC, flow rate output.
Digital HART protocol superimposed on a 4–20mA signal, available to any host that conforms to the HART protocol.
Power SupplyExternal power supply required. Operates on 10.5-55VDC with no load.
4–20mA Load Limitations
Maximum loop resistance is determined by the voltage level of the external power supply, as shown in the following flowmeter chart.
FIGURE 30. Load Limitations.For CSA Approval, powersupply must not exceed 42.2V.
Pressure Limits
0 to 1440 psig (100 barg) @ 100 °F (37.8 °C). Contact the factory for higher pressures.
TemperatureStorage: -50 °F to 230 °F (-46 °C to 110 °C).
With integral meter: -40 °F to 185 °F (-40 °C to 85 °C).
For HATSB, HVTSB, HADSB, and HVDSB head styles and regular flanged, Flo-Tap models: -40 °F to 750 °F (-40 °C to 398 °C).
Remote mount (SST and Monel):-40 °F to 850 °F (-40 °C to 454 °C).
Remote mount (Hastelloy-C):-40 °F to 900 °F (-40 °C to 482 °C).
Remote mount (Hastelloy-C) with remote temperature sensor :-40 °F to 1200 °F (-40 °C to 649 °C).
Ambient: -40 °F to 185 °F (-40 °C to 85 °C).
With integral meter: -4 °F to 175 °F (-20 °C to 80 °C).
Damping
Analog output response to a step input change is user selectable from 0 to 36 seconds for one time constant. This software damping is in addition to sensor module response time.
Turn on Time
Performance within specification less than two seconds after power is applied.
Humidity Limits
0 to 100% relative humidity.
(1) Fluid density and Reynolds number corrections should becompensated per DSI Annubar Handbook Equation #2.1-2.5.
(2) Consult the factory for line sizes > 72 inches. Multipointcalibration is available for line sizes 1/2 in. to 36 in. Consult thefactory for calibration ranges in larger line sizes.
(3) Consult the factory for calibration ranges for range 3.
1
1935
1500
500
0
10.5 20 30 40
42.4
55
Voltage (V dc)
Load
(O
hms)
OperatingRegion
1000
Flow-3
ProBar ® Flowmeter
ProB
ar®
PERFORMANCE SPECIFICATIONS
Accuracy (1)
(Including linearity, hysteresis, and repeatability)
Multipoint calibration: + 0.5% of rate (at reference conditions).
No Flow Calibration
+ 1.1% of volumetric flow rate.
+ 3% of volumetric flow rate, elbow mount.
Flow Turndown
10:1 flow turndown—multipoint calibration.(2)
5:1 flow turndown—no calibration.
Stability
+ 0.25% of URL for five years.
Time Response (Electronics Only)
Dead time (Td): 45 milliseconds (nominal).
Time constant (Tc): 55 milliseconds.
Update rate: 20 times per sec. (minimum).
Vibration Effect
Less than 0.1% of URL per g when tested from 15 Hz to 2000 Hz in any axis relative to pipe-mounted process conditions.
Power Supply Effect
Less than 0.005% of calibrated span per volt.
RFI Effect
0.1% of span from 20 MHz to 1000MHz and for field strength up to 30 V/m.
Ambient Temperature Effect
Per 50 °F (28 °C):
• +(0.0188% URL + 0.0938% span) spans from 1:1 to 10:1.
• +(0.038% URL + 0.188% span) spans from 10:1 to 100:1.
For range 1: +(0.18% URL + 0.375% span).
Static Pressure Effect
Zero error (can be calibrated out at line pressure).
• 0.1% of URL/1,000 psi (6.9MPa) for line pressures from 0 to 2,000 psi (0 to 13.7MPa).
• 0.2% of URL/1,000 psi (6.9MPa) for line pressure above 2,000 psi (13.7MPa).
For range 1:0.25% of URL/1,000 psi (6.9MPa).
Mounting Position Effect
Zero shifts up to 2.5 inches ws (0.62kPa) which can be calibrated out. No span effect.
ProBar Flowmeter Operating Limitations
See the ProBar® Flow Handbook (DS-4012 or 00807-0100-1192) for detailed information.
(1) Calibration not available for Range 0.Water Flow Calibration (Test condition: Water at 60 °F, 50 psig,in sch40, sch80, or sch std pipes) in totalizing test conditions.
(2) Flow turndown is based on the upper range limit of the rangeselected and may vary depending on customer application, orProBar operating limitations
Model Minimum Reynold’s Number (Re rod )
10 2300
½ inch 4000
15/16 6500
25/26 10000
35/36 15000
45/46 25000
Where:
Rerod = dVρm
ρ = fluid density in lbm/ft3
d = probe width in feet
V = velocity of fluid in ft/sec
m = fluid viscosity in lbm/ft–sec
72
Rosemount Inc.
Pro
Bar
®
PHYSICAL SPECIFICATIONS
Electrical Considerations
½ in.— 14 NPT, PG 13.5, and CM20 conduit. HART interface connections permanentlyfixed to terminal block.
SENSOR
316/316L SST.
Hastelloy–C (Flanged models, Sensors 10, 25/26, 45/46).
Monel (Flanged models, Sensors 10, 25/26, 45/46).
Integral Valve and Direct MountHead Styles (3 and 5 Valve)
Material
316 SST (Hastelloy–C and Monel options).
O–Rings
Teflon® (Grafoil above 500 °F [260 °C]).
Bolts
316 SST.
Flange and Isolation Valves
316L SST. Flange pressure limits are per ANSI B16.5 for 316 SST and material per SA182. Flange face finish ANSI B16.5, 125 to 250 RMS.
Packing Gland Assembly
Packing Gland
316 SST.
Packing
Graphite AFP–127.
Flange Mounting Hardware
(Includes nuts, bolts, and gasket) 316 SST or CS.
Temperature Options
Integral RTD
100 Ω Platinum RTD.
Remote
100 Ω Platinum RTD.
Spring loaded with ½ —14 NPT nipple and union.
Thermowell: ½ in. × ½ —14 NPT, 316 SST with½ in. CS weld couplet, u = 2 in. × 2 in.
Electronics
Stainless steel models.
• Vent valves and process flanges: 316 SST• Process isolating diaphragms: 316L SST• O-rings: Glass-filled TFE
Hastelloy-C Models
• Vent valves and process flanges: Hastelloy–C models.
• Process isolating diaphragms: Hastelloy–C models.
• O-rings: Glass-filled TFE.
Monel Models
• Vent valves and process flanges: Monel.• Process isolating diaphragms: Monel.• O-rings: Glass-filled TFE.
Hazardous Locations Certifications
Factory Mutual (FM) ApprovalsE5 — Explosion Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition Proof for Class II, Division 1, Groups E, F, and G. Dust-Ignition Proof for Class III, Division 1. NEMA 4X. Factory-sealed.
I5 — Intrinsically safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1 when connected in accordance with Rosemount drawings 03031-1019 and 00275-0081 (when used with HART Communicator Model 275), or 00268-0031 (when used with Rosemount Model 268 Communicator). Temperature Code T4. Non-incendive for Class I, Division 2, Groups A, B, C, and D. NEMA 4X. Factory-sealed.
K5 — Combination of E5 and I5. NEMA 4X. Factory-sealed.
FM Approved Entity Parametersfor Model 8900V (1)
(1) When connected in accordance with Rosemount drawings 3031-1019 and 00275-0081 (for use with the HART CommunicatorModel 275), or 00268-0031 (for use with the Rosemount Model268 Communicator.)
FMApprovedfor ClassI, II,andIII;Division 1 and 2; Groups
VMax = 40 V dcIMax = 165 mAIMax = 225 mAIMax = 160 mA (Option Code T1)PMax = 1 WCI = 0.01 µF (Output Code A)LI = 10 µHLI = 1.05 mH (Output Code A with T1)
A – GA – GC – GA – GA – GA – GA – GA – G
Flow-373
Flow-3
ProBar ® Flowmeter
ProB
ar®
00813-0100-4761 Rev. DA 11/98
¢00809-0100-4716;¤
Dieterich Standard Inc.5601 North 71st StreetBoulder, CO 80301Tel (303) 530-9600Fax (303) 530-7064
© 1998 Rosemount Inc.http://www.rosemount.com PR
INTED
INU.S. A.
Fisher-RosemountSingapore Pte Ltd.1 Pandan CrescentSingapore 128461Tel (65) 777-8211Fax (65) 777-0947Tlx RS 61117 FRSPL
Fisher-Rosemount LimitedHeath Place Bognor RegisWest Sussex PO22 9SHEnglandTel 44 (1243) 863 121Fax 44 (1243) 867 5541
Rosemount Inc.8200 Market BoulevardChanhassen, MN 55317 USATel 1-800-999-9307Telex 4310012Fax (612) 949-7001
Canadian Standards Association (CSA)
C6 — Explosion Proof for Class I, Division 1, Groups C, and D. Dust-Ignition Proof for Class II, Division 1, Groups E, F, and G. Dust-Ignition Proof for Class III, Division 1. Suitable for Class I, Division 2, Groups A, B, C, and D. CSA Enclosure-Type 4X. Factory-sealed.
Intrinsically safe for use in Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings 03031-1024. Temperature Code T3C. CSA Enclosure-Type 4X. Factory-sealed.
(2) When connected in accordance with Rosemount drawings00275-0082 and 3031-1024.
KEMA/CENELECED — Explosion Proof. EEx d IIC T5 (Tamb = 70 C); EEx d IIC T6 (Tamb = 40 C). Enclosure Type: IP65.
ID — Intrinsically Safe. EEx ia IIC T5 (Tamb = -45 to +40 °C); EEx ia IIC T54 (Tamb = -45 to +70 °C). Enclosure Type: IP65.Ui = 30V dc.Ii = 200 mA.Pi = 0.9 W.Ci = 0.012 µF.Li = 0.CSA Approved
Barriers for Model 8900V (2)
CSA Approvedfor ClassI, Division 1 and 2,Groups
Out
put
Cod
eA
≤ 30 V, ≥ 330 V ≤ 28 V, ≥ 300 V≤ 25 V, ≥ 200 V ≤ 22 V, ≥ 180 V A–D
≤ 30 V, ≥ 150 V C–D
Ou
tput
Cod
eM
Supply ≤ 28V, ≥ 300 VReturn ≤ 10 V, ≥ 47 V A–D
Supply ≤ 30 V, ≥ 150 VReturn ≤ 10 V, ≥ 47 V
C–D
May be protected by one or more of the following U.S. Patent Nos.4,559,836; 4,717,159; 5,710,370; 5,773,726; 4,633,713;and various foreign patents. Other foreign patents issued and pending.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.Coplanar, MV, and Multivariable are trademarks of Rosemount Inc.PlantWeb is a mark of the Fisher-Rosemount group of companies.Mass ProBar, ProBar, and Annubar are registered trademarks of Dieterich Standard Inc.HART is a registered trademark of the HART Communications Foundation.Monel is a registered trademark of International Nickel Co.Teflon is a registered trademark of E. I. du Pont de Nemours & Co.Hastelloy C and Hastelloy C-276 are registered trademarks of Cabot Corp.Windows is a trademark of Microsoft Corp.
74