41
PROASYS ® Mike Hyde – Northern Neck EC Kevin Fulks – Ozark EC (MO) Bill Ntwali – Aclara

PRO asys ®

  • Upload
    junior

  • View
    101

  • Download
    1

Embed Size (px)

DESCRIPTION

PRO asys ®. Mike Hyde – Northern Neck EC Kevin Fulks – Ozark EC (MO) Bill Ntwali – Aclara. Overview. Common uses of PRO asys ® Operate the system stand-alone or in conjunction with other outage systems. Different ways to view results Email notifications and map configurations - PowerPoint PPT Presentation

Citation preview

Page 1: PRO asys ®

PROASYS®

Mike Hyde – Northern Neck ECKevin Fulks – Ozark EC (MO)

Bill Ntwali – Aclara

Page 2: PRO asys ®

Overview

• Common uses of PROASYS®

• Operate the system stand-alone or in conjunction with other outage systems.

• Different ways to view results• Email notifications and map configurations• Understand PROASYS

® related database tables and their

relationships.• Best practices for outage management

Page 3: PRO asys ®

Documentation

Map DataMinimum Requirements

SerialnumberProt_device_networkSubstation_locationsTransformer_LocationsMeter_Locations

Page 4: PRO asys ®

PROASYS®

The PROASYS WebEx is a 120 minute live demo.Remaining WebEx Classes:

•May 18•June 9•July 7•August 31

•September 8•October 25•November 22•December 10

Page 5: PRO asys ®

PROASYS Ping (Map)

Page 6: PRO asys ®

PROASYS Ping (Web)

Page 7: PRO asys ®

Outage Event

Shows jobs running in PROASYS

Page 8: PRO asys ®

(From page 32 of the PROASYS User Guide)

HierarchyTraverse Network

(From page 25 of the PROASYS User Guide)

Page 9: PRO asys ®

Minimum Requirements for Traverse Network functionality:

• Serialnumber

• Prot_device_network

Table Relationships

Page 10: PRO asys ®

Table Relationships

Minimum Requirements for map display:

• Serialnumber

• Prot_device_network

• Substation_locations

• Transformer_Locations

• Meter_Locations

Page 11: PRO asys ®

Table RelationshipsHierarchy, Location, Outage, Blink & Voltage

Page 12: PRO asys ®

Hierarchy

Page 13: PRO asys ®

SERIALNUMBER Table

Page 14: PRO asys ®

SERIALNUMBER Table

Updating SERIALNUMBER TableText file from Milsoft

SQL script generated by utility program

Page 15: PRO asys ®

PROT_DEVICE_NETWORK Table

Page 16: PRO asys ®

PROT_DEVICE_NETWORK Table

Creating PROT_DEVICE_NETWORK Table

Text file from Milsoft SQL script generated by utility program

Page 17: PRO asys ®

Source Code

Page 18: PRO asys ®

Hierarchy

Page 19: PRO asys ®

PROASYS Submission

• Commands are inputted via SQL into the ODMARM_INPQ table

• 4 Commands– START – Starts the new batch job– Add – Specifies the devices to ping– Close – Closes the batch job– Cancel – Cancel the job

Page 20: PRO asys ®

The MeatThe queries used to insert jobs into PROASYS

Page 21: PRO asys ®

Group ID

Page 22: PRO asys ®

Start Command Creation

Page 23: PRO asys ®

Start Command SQL

Page 24: PRO asys ®

Add

Page 25: PRO asys ®

Close

Page 26: PRO asys ®

End of Job ActionsFast Ping (OOB)

Page 27: PRO asys ®

End of Job ActionsFast Ping (Homegrown)

Page 28: PRO asys ®

End of Job Actions

Voltage Ping (OOB)

Page 29: PRO asys ®

End of Job ActionsVoltage Check - Homegrown

Page 30: PRO asys ®

External Data Uses

• Meter_Voltage_Reading• Meter_Blink_Counts• Outage_Summary• Outdet_log• Outdet_Status_defs• Outage_Counts• Outage_Summary

Page 31: PRO asys ®

METER_VOLTAGE_READING

Page 32: PRO asys ®

METER_BLINK_COUNTS

Page 33: PRO asys ®

OUTAGE_SUMMARY

Page 34: PRO asys ®

OUTDET_LOG

Page 35: PRO asys ®

OUTDET_STATUS_DEFS

Page 36: PRO asys ®

Ping Results (Web - Live)

Ping ResultsReport

Page 37: PRO asys ®

Ping Results (Web - Live)

Ping ResultsDevice Hierarchy

Page 38: PRO asys ®

PingBotOutage Received • Web• IVR• Phone• CRC

Page 39: PRO asys ®

PingBotCheck Account Status• Active –

– Ping– Notify Dispatchers &

Duty Supervisors– Check ping results– Notify Dispatchers &

Duty Supervisors• In-Active

Notify Customer Service

Page 40: PRO asys ®

Resources

• PROASYS User Guide (Y10338TM)• PROASYS Third Party Interface

Technical Manual (Y10576-TUM)• Table Information• Portal – Discussion Threads• Right here

Page 41: PRO asys ®

Future Plans

• Map icons – Differentiate Voltage pings• Enhance PingBot• Determine actual failed device• Alerts to trucks (AVL)