PRIMERGY TX200 S4 Server Options Guide Edition April 2008

PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

Embed Size (px)

Citation preview

Page 1: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

PRIMERGY TX200 S4 Server Options Guide

Edition April 2008

Page 2: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2008 Fujitsu Siemens Computers GmbH.

All rights reserved.

Delivery subject to availability. The right to technical modification is reserved.

All hardware and software names used are trade names and/or trademarks of their respective manufacturers.

Page 3: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide

Contents

1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 7

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . . 7

1.3 Expansions and conversions . . . . . . . . . . . . . . . . . . 9

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 11

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 15

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 214.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 21

4.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 224.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 22

4.3 System fans and traverse . . . . . . . . . . . . . . . . . . . 244.3.1 Removing the system fan 1 . . . . . . . . . . . . . . . . . . . 244.3.2 Removing the system fan 2 . . . . . . . . . . . . . . . . . . . 254.3.3 Removing the traverse with the air duct over the main memory . 254.3.4 Removing the system fan 3 . . . . . . . . . . . . . . . . . . . 26

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 27

5.1 Equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 27

5.2 Expanding/replacing the main memory . . . . . . . . . . . . 28

Page 4: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

Options Guide TX200 S4

Contents

6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

6.1 Installing a second processor . . . . . . . . . . . . . . . . . 31

6.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 35

6.3 Replacing the heat sink . . . . . . . . . . . . . . . . . . . . . 37

7 Accessible drives and LSP . . . . . . . . . . . . . . . . . . . 39

7.1 Installing an accessible 5.25-inch drive . . . . . . . . . . . . 39

7.2 Installing the multibay . . . . . . . . . . . . . . . . . . . . . . 427.2.1 Installing a LSP in the multibay . . . . . . . . . . . . . . . . . . 46

7.3 Installing a hard disks extension box . . . . . . . . . . . . . 48

8 Expansion cards and BBU . . . . . . . . . . . . . . . . . . . 57

8.1 Installing expansion cards . . . . . . . . . . . . . . . . . . . 57

8.2 Installing a BBU . . . . . . . . . . . . . . . . . . . . . . . . . 61

8.3 Installing the Performance Adapter . . . . . . . . . . . . . . 64

9 SATA SW RAID . . . . . . . . . . . . . . . . . . . . . . . . . . 65

9.1 Inserting the RAID key . . . . . . . . . . . . . . . . . . . . . 65

10 Parallel interface for printers . . . . . . . . . . . . . . . . . . 67

10.1 Installing a parallel interface . . . . . . . . . . . . . . . . . . 67

11 Conversion to hot-plug PS and redundant system fans . . . 69

12 Conversion from a floorstand model to a rack model . . . . . 81

Page 5: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide

Contents

13 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

13.1 System fans and traverse . . . . . . . . . . . . . . . . . . . 8513.1.1 Installing the system fan 3 . . . . . . . . . . . . . . . . . . . . 8513.1.2 Installing the traverse with the air duct over the main memory . 8613.1.3 Installing the system fan 2 . . . . . . . . . . . . . . . . . . . . 8613.1.4 Installing the system fan 1 . . . . . . . . . . . . . . . . . . . . 87

13.2 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 8913.2.1 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 89

13.3 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 9013.3.1 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 90

14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

14.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Page 6: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 7: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 7

1 PrefaceThe PRIMERGY TX200 S4 server is an Intel-based server for mid-size and large companies. The server is suitable for use as a file server and also as an application, information or Internet server. It is available as a floorstand or rack model. The floorstand model can be converted to a rack model using an optional conversion kit.

1.1 Concept and target groups

This Options Guide shows you how to extend and upgrade your server.

V CAUTION!

The activities described in this manual may only be performed by technical specialists.

I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server.

1.2 Documentation overview

More information on your PRIMERGY TX200 S4 can be found in the following documents:

– “Quick Start Hardware - PRIMERGY TX200 S4” leaflet (only included as a printed copy)

– “Quick Start Software - Quick Installation Guide” leaflet (only included as a printed copy)

– “Safety notes and other important information” manual

– “Warranty” manual

– “Customer Self Service (CSS)” manual

– “Ergonomics” manual

– “Returning used devices” manual

– “Helpdesk” leaflet

– Technical manual for the system board D2509

Page 8: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

8 Options Guide TX200 S4

Documentation overview Preface

– “PRIMERGY TX200 S4 Server Operating Manual”

– “PRIMERGY TX200 S4 Server Options Guide”

– “BIOS Setup V4.06 / FirstBIOS Desktop Pro V5.0 /TrustedCoreTM V6.0” manual

– “iRMCS2 - integrated Remote Management Controller” manual

– "LSI SATA Software RAID User’s Guide"

– "Integrated RAID for SAS User’s Guide"

– “SAS/SATA Controller MegaRAID 1064 / 1068 / 1078 Installation Guide”

I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the ServerView Suite supplied with every server.

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL: http://manuals.fujitsu-siemens.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

If you need a replacement copy of the ServerBooks DVD, send the details of your server to the following e-mail address: [email protected]

Further sources of information:

– Manual for the monitor– Documentation for boards and drives– Documentation for your operating system– Information files on your operating system

Page 9: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 9

Preface Expansions and conversions

1.3 Expansions and conversions

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency as the first.

Main memory expansion

6 slots (2 slots form a memory bank) are provided for the main memory. Each memory bank can be populated with two 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 Gbyte FDB667/PC2-5300F fully buffered DIMM memory modules.

Accessible drives

Three 5.25-inch bays are available for accessible drives. In these bays you can install DVD/DVD-RW drives, magnetic tape drives, a multibay (slimline DVD and FDD/ServerView Local Service Panel) or a hard disks extension box.

ServerView Local Service Panel

The system board supports the CSS (Customer Self Service) functionality (description see the operating manual). You can install a ServerView Local Service Panel for an easier identification of the defective components.

Hard disks extension box

Two 5.25-inch bays for accessible drives can be used to install a hard disks extension box.

Two variants of the hard disks extension box are available:

– Variant 1:

one bay for a ServerView Local Service Panel, one bay for a slimline DVD drive and two bays for 3.5“ hard disks

– Variant 2:

eight bays for 2.5“ hard disks

Page 10: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

10 Options Guide TX200 S4

Expansions and conversions Preface

Additional expansion cards in the PCI slots

The system board offers seven PCI slots:

– 2 x PCI-X slots(64 bit / 133 MHz IOOPTM)– 4 x PCI-Express slots, Gen1, mechanical PCIe x8– 1 x PCI-Steckplatz (32 Bit / 33 MHz)

Performance Adapter SNR: S26361-D2504

The Performance Adapter combines two PCIe x4 slots to one PCIe x8 slot. If the adapter has been installed in slot 2 (or 7), slot 1 (or 6) can be operated as PCIe x8.

SATA Software RAID

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

Parallel interface for printers

As an option, a parallel interface can be provided for printers.

Conversion standard power supply to hot-plug power supply and standard system fans to redundant system fans

The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules.

If one power supply module fails, the other power supply module guarantees the unrestricted operation and the defective power supply module can be replaced be replaced while the system is operating (hot-plug).

The standard system fans can be upgraded to redundant system fans. If the redundant system fans are installed, the fans are operating in a redundant configuration. A defective system fan can be replaced during the next service.

Conversion from a floorstand model to a rack model

The floorstand model can be optionally converted to allow the server to be installed into any typical rack systems.

Page 11: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 11

Preface Notational conventions

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

“Quotation marks” indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 12: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 13: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 13

2 ProcedureV CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

I Procedures which are identical for the floorstand and rack models are only described for the floorstand model.

Ê First of all, carefully read the safety instructions in the chapter “Safety instructions” on page 15 et seq..

Ê Make sure that all necessary manuals (see the section “Documentation overview” on page 7) are available; print the PDF files if required. Most importantly, you will need the operating manual for the server and the technical manual for the system board.

Ê Shut the server down correctly, switch it off, disconnect the power plugs and open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Carry out the expansion or upgrade of your server as described in the pertinent chapter.

I Installation and removal of the hot-plug components are described in the operating manual.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Ê Start the operating system and make the appropriate configuration if necessary (see the operating manual).

Page 14: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 15: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 15

3 Safety instructionsI The following safety instructions are also provided in the manual “Safety

notes and other important information”.

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS failures must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Page 16: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

16 Options Guide TX200 S4

Safety instructions

Before starting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● This unit should not be operated in ambient temperatures above 35 °C.

● If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors.

● The unit automatically adjusts itself to a mains voltage in a range of 100 V - 240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded shock-proof sockets or insulated sockets of the rack's internal power supply with tested and approved power cables.

● Ensure that the device is connected to a grounded shockproof socket close to the device.

Page 17: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 17

Safety instructions

V CAUTION!

● Ensure that the power sockets on the device and the grounded shock-proof sockets are freely accessible.

● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded shockproof sockets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded.

● The EN 50173 and EN 50174-1/2 standards apply for LAN cabling. The minimum requirement is the use of a category 5 screened LAN cable for 10/100 Mbps Ethernet, or a category 5e cable for Gigabit Ethernet. The requirements from the ISO/IEC 11801 specification must also be met.

● Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual.

● Never connect or disconnect data transmission lines during a storm (risk of lightning strike).

● Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team.

Page 18: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

18 Options Guide TX200 S4

Safety instructions

V CAUTION!

● Proper operation of the system (in accordance with IEC 60950-1/ EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expan-sions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet.

● The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: hot-plug power supply units/CCS components can be replaced.

● The warranty is void if the server is damaged during installation or replacement of system expansions.

● Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.

Batteries

V CAUTION!

● Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board).

● Replace the lithium-battery on the system board in accordance with the instructions in the technical manual for the system board.

Working with CDs/DVDs and CD/DVD drives

When working with devices with CD/DVD drives, these instructions must be followed.

Page 19: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 19

Safety instructions

V CAUTION!

● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance.

Damaged and imbalanced CDs/DVDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD fragments can pierce the cover of the CD/DVD drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

I You can prevent mechanical damage and damage to the CD/DVD drive, as well as premature CD/DVD wear, by observing the following sugges-tions:

– Only insert CDs/DVDs in the drive when needed and remove them after use.

– Store the CDs/DVDs in suitable sleeves.– Protect the CDs/DVDs from exposure to heat and direct sunlight.

Laser information

The CD/DVD drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The CD/DVD drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the CD/DVD drive casing!

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Page 20: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

20 Options Guide TX200 S4

Safety instructions

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 21: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 21

4 PreparationV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

4.1 Floorstand model

4.1.1 Opening the server

Ê Exit all applications and shut down the server properly.

Ê Press the On/Off button if the server has not been switched off by the operating system.

Ê Pull all power connectors out of the power outlets.

Figure 2: Opening the server

Ê Open the latch (1).

The opening of the latch pushes back the side cover and disengages the hooks on the top of the side cover.

Ê Remove the side cover (2).

1

2

Page 22: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

22 Options Guide TX200 S4

Rack model Preparation

4.2 Rack model

Ê Exit all applications and shut down the server properly.

Ê Press the On/Off button if the server has not been switched off by the operating system.

Ê Pull all power connectors out of the power outlets.

4.2.1 Opening the server

Pulling the server out of the rack and opening the server

Figure 3: Loosening the knurled screws

Ê Loosen the two knurled screws (1) and pull the server as far as possible out of the rack (2).

Ê Open the latch (see also the figure 2 on page 21).

Ê Remove the top cover.

Removing the server from the rack and opening the server

Depending on how accessible the server is in the rack cabinet, it can make sense to remove the server from the rack cabinet:

Ê Disconnect all cables on the rear of the server.

1

21

Page 23: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 23

Preparation Rack model

Figure 4: Loosening the screws in the rack cabinet

Ê Loosen the screws (1+2) on the left and the right side at the rear side.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

Ê Loosen the two knurled screws at the front side (see the figure 3 on page 22) and pull the server carefully out of the rack.

V CAUTION!

If you pull out the server too far, the server will fall down.

Ê Lift the server out of the rails and place it on a table, for example.

Ê Open the latch (see also the figure 2 on page 21).

Ê Remove the top cover.

1

2

Page 24: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

24 Options Guide TX200 S4

System fans and traverse Preparation

4.3 System fans and traverse

4.3.1 Removing the system fan 1

Figure 5: Removing the system fan 1

Ê Disconnect the fan cable from the connector FAN1 SYS on the system board.

Ê Push the lock (1) of the air duct inward.

Ê Push the air duct to the front side (2) until the pins on the PSU casing and the traverse disengage.

Ê Remove the air duct with the integrated system fan 1.

1

2

Page 25: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 25

Preparation System fans and traverse

4.3.2 Removing the system fan 2

Figure 6: Removing the system fan 2

Ê Disconnect the fan cable from the connector FAN2 SYS on the system board.

Ê Pull the lock (1) in direction of the traverse and swivel the system fan 2 up and out.

Ê Remove the system fan 2 in direction of the arrow (2).

4.3.3 Removing the traverse with the air duct over the main memory

Ê Remove the system fan 1 and system fan 2.

Figure 7: Removing the traverse

Ê Push the lock (1) and pull out the traverse (2).

Ê Unhook the traverse (3).

1

2

312

Page 26: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

26 Options Guide TX200 S4

System fans and traverse Preparation

Ê Take the traverse with the memory air duct carefully out of the housing.

4.3.4 Removing the system fan 3

Ê Remove the system fan 1, the system fan 2 and the traverse.

Figure 8: Removing the system fan 3

Ê Disconnect the fan cable from the connector FAN3 SYS on the system board.

Ê Push the lock in direction of the arrow (1).

Ê Pull the system fan 3 in direction of the arrow (2) to disengage the four hooks.

Ê Remove the system fan 3 (3).

2

3

1

Page 27: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 27

5 Main memoryV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

The system board supports up to 24 Gbyte of main memory. Main memory 6 slots (2 slots form a memory bank) are provided for the main memory. Each memory bank is equipped with two 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 FBD667/PC2-5300F Fully Buffered DIMM memory modules.

As memory bank 1 is already equipped either with 1 Gbyte, 2 Gbyte, 4 Gbyte or 8 Gbyte of memory in the basic unit, the memory extensions can be performed up to two times for memory banks 2 and 3.

ECC with memory scrubbing and with the Single Device Data Correction (SDDC, Chipkill) function is standard.

5.1 Equipping rules

Figure 9: Configuration of the main memory in memory banks and memory modules

– The memory modules have to be based on x4 or x8 organised single or dual ranked FDB667/PC2-5300 fully buffered DIMM modules and must be populated in pairs. It is only allowed you use memory modules released by Fujitsu Siemens Computers.

– Each pair must consist of identical memory modules.

– The module capacity between pairs can differ: pair 1A/1B can be populated with two 512 Mbyte modules and pair 2A/2B with two 1 Gbyte modules.

DIMM-3B

DIMM-2B

DIMM-1B

DIMM-3A

DIMM-2A

DIMM-1A

Page 28: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

28 Options Guide TX200 S4

Expanding/replacing the main memory Main memory

The following table shows the prescribed equipping order:

5.2 Expanding/replacing the main memory

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21 et seq..

Figure 10: Removing a memory module

Ê Fold the assembly brackets outwards on both sides of the corresponding slot (1).

Ê If the slot was equipped: pull the memory module out of the slot (2).

module pair 1A/1B(black)

module pair 2A/2B(blue)

module pair 3A/3B(blue)

equipped empty empty

equipped equipped empty

equipped equipped equipped

12

1

Page 29: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 29

Main memory Expanding/replacing the main memory

Figure 11: Installing a memory module

Ê Fold the assembly brackets outwards on both sides of the corresponding slot.

Ê Carefully press the memory module into the slot (1) until the fastening tabs on both sides of it engage (2).

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

21

2

Page 30: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 31: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 31

6 ProcessorsV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

V CAUTION!

Processors are modules which can react extremely sensitively to electro-static discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never push a processor over a surface.

6.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor and a heat sink.

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have at least the same clock frequency as the first processor. If the two processors have different clock frequencies, they both will operate with the lower clock frequency.

For dual operation, use a suitable multiprocessor operating system.

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21 et seq..

Page 32: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

32 Options Guide TX200 S4

Installing a second processor Processors

Installing the processor and the heat sink

Figure 12: Releasing the lever

Ê Release the socket lever by pressing it sideways and pull it upward as far as it will go (1).

Ê Open the cover (2).

Figure 13: Inserting the second processor

Ê Position the second processor over the socket and then carefully press it into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners (a). To avoid damaging the processor, do not force it into the socket.

1

2

a

1

Page 33: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 33

Processors Installing a second processor

Figure 14: Fastening the second processor

Ê Close the cover (1).

Ê Push down the socket lever slowly (2) until it hooks in place (3).

Ê Remove the plastic cover (4).

Figure 15: Removing the protective cover

Ê Remove the protective cover on the underside of the heat sink.

1

2

3

4

Page 34: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

34 Options Guide TX200 S4

Installing a second processor Processors

Figure 16: Installing the heat sink

Ê Place the heat sink on the processor socket.

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

V CAUTION!

Never install a processor without a heat sink and CPU fan as otherwise the processor may overheat, causing the processor and system board to fail.

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 35: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 35

Processors Replacing the processor

6.2 Replacing the processor

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have at least the same clock frequency as the first processor. If the two processors have different clock frequencies, they both will operate with the lower clock frequency.

For dual operation, use a suitable multiprocessor operating system.

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21 et seq..

Ê Loosen the four screws of the heat sink in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Remove the residual thermal paste from the underside of the heat sink.

Ê Clean the underside of the heat sink using a lint-free cloth.

Figure 17: Removing an old processor

Ê Release the socket lever by pressing it sideways and pull it upward as far as it will go (1).

Ê Open the cover (2).

Ê Lift the installed processor carefully out of the socket (3).

1

3

2

Page 36: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

36 Options Guide TX200 S4

Replacing the processor Processors

Figure 18: Inserting a new processor

Ê Position the new processor over the socket and thenplace it carefully into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners (a). To avoid damaging the processor, do not force it into the socket.

Figure 19: Fastening the new processor

Ê Close the cover (1).

Ê Push down the socket lever slowly (2) until it hooks in place (3).

Ê Apply a small amount of thermal paste to the upper side of the new processor.

a

1

1

2

3

Page 37: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 37

Processors Replacing the heat sink

Ê Ensure a thin and even distribution of the thermal paste.

Ê Place the heat sink on the processor socket (see page 34).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

6.3 Replacing the heat sink

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21et seq..

Ê Loosen the four screws of the heat sink socket in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Clean the upper side of the processor using a lint-free cloth.

Ê Remove the protective cover from the new heat sink (see page 33).

Ê Place the heat sink on the processor socket (see page 34).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 38: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 39: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 39

7 Accessible drives and LSPV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

Three 5.25-inch bays are available for accessible drives. In these bays you can install DVD/DVD-RW drives, magnetic tape drives, a multibay (slimline DVD and FDD/ServerView Local Service Panel) or a hard disks extension box.

7.1 Installing an accessible 5.25-inch drive

The 5.25-inch drives available are magnetic tape drives and DVD-ROM burners. These drives can be installed in the free 5.25-inch bays.

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

I If you install a magnetic tape drive with double height (3.2-inch), two dummy modules of the free 5.25-inch bays must be removed.

Figure 20: Removing the screws of the dummy module

Ê Remove the two screws (see the circles).

Page 40: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

40 Options Guide TX200 S4

Installing an accessible 5.25-inch drive Accessible drives and LSP

Figure 21: Removing the dummy module

Ê Push the dummy module out of the bay frontward.

V CAUTION!

Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Ê Push the new drive about halfway into the bay.

Ê Connect the data cable to the accessible drive (see the cabling plans in the Appendix).

Ê Connect the power cable to the accessible drive (see the cabling plans in the Appendix).

Ê Push the drive fully into the bay and fasten it with two screws.

Page 41: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 41

Accessible drives and LSP Installing an accessible 5.25-inch drive

Figure 22: Example cabling CD drive

Ê Connect the data cable to the system board (see the cabling plans in the Appendix).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 42: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

42 Options Guide TX200 S4

Installing the multibay Accessible drives and LSP

7.2 Installing the multibay

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the dummy module from a 5.25-inch bay for accessible drives:

Ê Remove the two screws of the corresponding bay.

Ê Push the dummy module out of the bay frontward.

V CAUTION!

Keep the dummy modules for future use. If you remove the multibay again and do not replace it with new drives, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 23: Pushing the floppy drive in the multibay

Ê Push the floppy drive in the multibay and fasten it with two screws on each side.

I You can install a LSP (ServerView Local Service Panel) instead of the floppy drive (see section “Installing a LSP in the multibay” on page 46).

Page 43: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 43

Accessible drives and LSP Installing the multibay

Figure 24: Removing the slimline dummy module

Ê Pull up the green touch point.

Ê Pull out the slimline dummy module frontward.

Figure 25: Removing the slimline frame

Ê Expand the frame sideward.

Page 44: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

44 Options Guide TX200 S4

Installing the multibay Accessible drives and LSP

Figure 26: Inserting the slimline drive in the frame

Ê Insert the slimline drive in the frame: the four noses fasten the drive to the frame.

Ê Push the slimline drive with its frame in the bay of the multibay until it engages.

Figure 27: Cabling of the slimline drive

Ê Connect the PS adapter cable to the slimline drive (see the cabling plans in the Appendix).

Ê Connect the SATA cable to the slimline drive (see the cabling plans in the Appendix).

Page 45: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 45

Accessible drives and LSP Installing the multibay

Figure 28: Installing the multibay

Ê Push the multibay with its cables in the lower bay until the holes fit to the threads.

Ê Fasten the multibay with two screws (see the circles).

Ê Connect the PS adapter cable of the slimline drive to a power plug (see the cabling plans in the Appendix).

Ê Connect a power plug to the floppy drive (see the cabling plans in the Appendix).

Ê Connect the floppy cable to the floppy drive and to the connector Floppy on the system board (see the cabling plans in the Appendix).

Ê Connect the SATA cable of the slimline drive to the system board (see the cabling plans in the Appendix).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 46: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

46 Options Guide TX200 S4

Installing the multibay Accessible drives and LSP

7.2.1 Installing a LSP in the multibay

Figure 29: LSP frame

Figure 30: Inserting a LSP in the frame

Ê Push the LSP in the frame until it engages in the upper recess (see the circle).

Page 47: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 47

Accessible drives and LSP Installing the multibay

Figure 31: Inserting a LSP in the multibay

Ê Push the frame in multibay from the rear side and fasten the frame with two screws on each side.

Figure 32: Cabling the LSP

Ê After installing the multibay in the server: connect the free plug of the I2C cable to the LSP.

Page 48: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

48 Options Guide TX200 S4

Installing a hard disks extension box Accessible drives and LSP

7.3 Installing a hard disks extension box

Two 5.25-inch bays for accessible drives can be used to install a hard disks extension box.

Two variants of the hard disks extension box are available:

– Variant 1:

one bay for a ServerView Local Service Panel, one bay for a slimline DVD drive and two bays for 3.5“ hard disks

– Variant 2 (special release required):

eight bays for 2.5“ hard disks

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the dummy modules from two 5.25-inch bays for accessible drives:

Ê Remove the two screws of the corresponding bay.

Ê Push the dummy module out of the bay frontward.

V CAUTION!

Keep the dummy modules for future use. If you remove the hard disks extension box again and do not replace it with new drives, the dummy modules must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 49: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 49

Accessible drives and LSP Installing a hard disks extension box

Removing and pushing inward of the metal brackets

The upper drives lay on four metal brackets. You have to remove and push inward the four metal brackets before it is possible to insert the hard disks extension box.

Figure 33: Removing the metal brackets - first step

Ê Break the two metal brackets out of the housing using a screws driver.

V CAUTION!

The sharp cant may hurt you!

Page 50: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

50 Options Guide TX200 S4

Installing a hard disks extension box Accessible drives and LSP

Figure 34: Removing the metal brackets - second step

Figure 35: Removing the metal brackets - third step

Ê Turn the two metal brackets around until they break out.

Page 51: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 51

Accessible drives and LSP Installing a hard disks extension box

Figure 36: Pushing inward the metal brackets - first step

Ê Break through the pointy sides of the two inner metal brackets using a screws driver.

Figure 37: Pushing inward the metal brackets - second step

Ê Push the metal brackets inward until they cannot blockade the interior space of the bay.

Page 52: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

52 Options Guide TX200 S4

Installing a hard disks extension box Accessible drives and LSP

3.5“ hard disks extension box

Ê Push the metal brackets inward until they cannot blockade the interior space of the bay.

Figure 38: Installing 3.5“ hard disks extension box

Ê Push the hard disks extension box fully into the bay and fasten it with four screws.

Figure 39: Example connecting the power cable

Ê Connect the power cable to the hard disks extension box (see the cabling plans in the Appendix).

Page 53: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 53

Accessible drives and LSP Installing a hard disks extension box

Figure 40: Example connecting the SATA cable

Ê Connect the SATA cable to the hard disks extension box and the second port of a controller (see the cabling plans in the Appendix).

I It is possible to install a slimline drive in the hard disks extension box. The procedure is the same as for installing the slimline drive in the multibay.

I It is possible to install a LSP in the hard disks extension box. In this case you can push the LSP in the top bay of the hard disks extension box without using a frame.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 54: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

54 Options Guide TX200 S4

Installing a hard disks extension box Accessible drives and LSP

2.5“ hard disks extension box

Ê Push the metal brackets inward until they cannot blockade the interior space of the bay.

Figure 41: Installing 2.5“ hard disks extension box

Ê Push the hard disks extension box fully into the bay and fasten it with three screws.

Figure 42: Example connecting the SATA cables to the controller

Ê Connect the SATA cable to the hard disks extension box and the second port of a controller (see the cabling plans in the Appendix).

Page 55: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 55

Accessible drives and LSP Installing a hard disks extension box

Figure 43: Example connecting the power and SAS cables

Ê Connect the power cables and the SAS cables to the hard disks extension box (see the cabling plans in the Appendix).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 56: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 57: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 57

8 Expansion cards and BBUV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

8.1 Installing expansion cards

The system board offers seven PCI slots:– 2 x PCI-X slots(64 bit / 133 MHz IOOPTM)– 4 x PCI-Express slots, Gen1, mechanical PCIe x8– 1 x PCI-Steckplatz (32 Bit / 33 MHz)

The hardware of the system board optimizes the speed of the PCI bus (IOOP™) for PCI slots 4 and 5, depending on how the slots are equipped. If only one of this two slots is occupied, the PCI bus speed is 133 MHz. If both slots are occupied, the PCI bus speed is 100 MHz.

I Performance Adapter SNR: S26361-D2504:

The Performance Adapter combines two PCIe x4 slots to one PCIe x8 slot. If the adapter has been installed in slot 2 (or 7), slot 1 (or 6) can be operated as PCIe x8.

I Modular RAID:

If a SAS or a SAS RAID controller for the internal hard disks should be installed in the SATA base unit, you have to connect the SATA CD-ROM to the SATA MLC1 connector on the system board using the cable T26361-Y3969-V201 (see figure 83 on page 98). This cable must be ordered seperately. After the installation the default settings in the BIOS setup must be set to enable the booting from the CD-ROM.

I Boot controller:

As default slot 1 is configured for the Boot controller. If a Boot controller should be operated in a different slot, it is necessary to modify the BIOS (Advanced/ PCI Configuration/ PCI SLOTS Configuartion/Option ROM Scan: enabled, see the manual BIOS-Setup). The option ROM Scan specifies whether the BIOS of the adapter in this PCI slot is started by the system BIOS.

Page 58: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

58 Options Guide TX200 S4

Installing expansion cards Expansion cards and BBU

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the system fan 2 as described in the section “Removing the system fan 2” on page 25.

Figure 44: Loosening the locking levers

Ê Press on the two green locking levers in the direction of the arrow and push the locking levers out of the housing.

Page 59: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 59

Expansion cards and BBU Installing expansion cards

Figure 45: Opening the slot locking bar

Ê Open the slot locking bar.

Page 60: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

60 Options Guide TX200 S4

Installing expansion cards Expansion cards and BBU

Figure 46: Removing the slot cover

Ê Remove the PCI slot cover.

V CAUTION!

Keep the slot cover for further use. If the expansion card is removed again and not replaced with a new one, the slot cover has to be reinstalled to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures.

Ê Unpack the new expansion card, and make the desired settings. You should read the accompanying documentation supplied with the expansion card beforehand.

Ê Install the expansion card into the PCI slot and press it carefully into the associated plug-in location on the system board until it engages properly.

Ê Close the slot locking bar and press on the two green locking levers at the server’s rear side until they engage.

Ê If required, connect the cables to the expansion card and other components.

Ê Install the system fan 2 as described in the section “Installing the system fan 2” on page 86.

Page 61: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 61

Expansion cards and BBU Installing a BBU

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

8.2 Installing a BBU

You can install up to two Battery Backup Units (BBU).

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the system fan 1, the system fan 2 and the traverse as described in the section “System fans and traverse” on page 24 et seq..

Figure 47: Connecting the cable to the BBU

Ê Connect the cable to the BBU and the expansion card.

V CAUTION!

Make sure that the connector side with two pin rows is on the top. Otherwise you risk short-circuits.

Page 62: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

62 Options Guide TX200 S4

Installing a BBU Expansion cards and BBU

Ê Install the expansion card.

Figure 48: Inserting the BBU

Ê Push the BBU in the housing.

Side with one pin row: Side with two pin rows:

Page 63: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 63

Expansion cards and BBU Installing a BBU

Figure 49: Position screws

Ê Fasten the BBU with three screws at the outer side (the first BBU in the front range, a second BBU in the middle range).

Ê Install the traverse, the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

BBU 1BBU 2

Page 64: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

64 Options Guide TX200 S4

Installing the Performance Adapter Expansion cards and BBU

8.3 Installing the Performance Adapter

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the system fan 1 and the system fan 2 as described in the section “System fans and traverse” on page 24 et seq..

Figure 50: Performance Adapter in slot 7

Ê Insert the Performance Adapter in slot 2 or slot 7.

Ê Install the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 65: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 65

9 SATA SW RAIDV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

9.1 Inserting the RAID key

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the system fan 2 as described in the section “Removing the system fan 2” on page 25.

Figure 51: Inserting the RAID key

Ê Insert the RAID key in the round socket on the system board.

Ê Install the system fan 2 as described in the section “Installing the system fan 2” on page 86.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 66: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 67: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 67

10 Parallel interface for printersV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

10.1 Installing a parallel interface

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the system fan 1, the system fan 2 and the traverse as described in the section “System fans and traverse” on page 24 et seq..

Ê Install the parallel interface as described in the section “Installing expansion cards” on page 57 et seq..

Figure 52: Routing the cable

Ê Route the cable as shown in the photo.

Ê Connect the cable’s connector to the parallel port connector on the system board.

Page 68: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

68 Options Guide TX200 S4

Installing a parallel interface Parallel interface for printers

Ê Install the traverse, the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 69: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 69

11 Conversion to hot-plug PS and redundant system fans

V CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

Ê Remove the system fan 1, the system fan 2 and the traverse as described in the section “System fans and traverse” on page 24 et seq..

Figure 53: Removing the power cables

Ê Disconnect all power cables from the system board and the drives (see the cabling plans in the Appendix).

Ê Thread the power cables through the openings.

Page 70: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

70 Options Guide TX200 S4

Conversion to hot-plug PS and redundant system fans

Figure 54: Removing the PSU

Ê Remove the four screws and pull the power supply unit inward and take it out of the server.

Figure 55: Removing the adapter metal cover

Ê Remove the six screws and push the adapter metal cover inward in a slight angle and take it out of the server.

Page 71: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 71

Conversion to hot-plug PS and redundant system fans

Figure 56: Installing the Power backplane in the PS cage

Ê Insert the Power backplane in the PS cage.

Ê Push the Power backplane in direction of the arrow until it engages in the guidances of the PS cage.

Ê Fasten the Power backplane with one screw (see circle).

Page 72: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

72 Options Guide TX200 S4

Conversion to hot-plug PS and redundant system fans

Figure 57: Breaking out the pre-cut plate

Ê Break out the pre-cut plate for the plug of the redundant fan using a screws driver.

Figure 58: Inserting the redundant fan

Ê Insert the redundant fan with its holder in the four recesses at the rear side of the housing.

Page 73: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 73

Conversion to hot-plug PS and redundant system fans

Figure 59: Fastening the holder

Ê Push the holder to the left side until the four hooks engage.

Ê Fasten the holder with three screws.

Page 74: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

74 Options Guide TX200 S4

Conversion to hot-plug PS and redundant system fans

Figure 60: Installing the PS cage

Ê Push the PS cage from the rear side into the housing. In the floorstand model the Power backplane is positioned under the top cover, and in the rack model at the right-hand side cover (seen from front side).

V CAUTION!

Make sure that the noses of the PS cage engage in the housing (see circles).

Page 75: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 75

Conversion to hot-plug PS and redundant system fans

Figure 61: Fastening the PS cage

Ê Fasten the PS cage with three screws.

Figure 62: Cabling of the redundant fan

Ê Connect the cable T26139-Y3908-V101 to the system board connector Fan4 SYS and to the fan connector (see the cabling plans in the Appendix).

Page 76: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

76 Options Guide TX200 S4

Conversion to hot-plug PS and redundant system fans

Figure 63: PS cabling - step 1

Ê Thread the power cable T26139-Y3758-V5 through the recess.

Ê Connect the power cable to the connector X3 on the Power backplane.

Ê Connect the power cable to the connector PWR1 on the system board.

Page 77: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 77

Conversion to hot-plug PS and redundant system fans

Figure 64: PS cabling - step 2

Ê Thread the power cable T26139-Y3952-V2 through the recess.

Ê Connect the power cable to the connector X4 on the Power backplane.

Ê Connect the power cable to the connectors PWR3, PWR2 and PC98 on the system board.

Page 78: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

78 Options Guide TX200 S4

Conversion to hot-plug PS and redundant system fans

Figure 65: PS cabling - step 3

Ê Thread the power cable T26139-Y3952-V101 through the recess.

Ê Connect the power cable to the connector X5 on the Power backplane.

Ê Connect the plugs of the power cable to the drives and the HDD backplanes (see the cabling plans in the Appendix).

Page 79: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 79

Conversion to hot-plug PS and redundant system fans

Figure 66: Installing the PS safe guard

Ê Install the PS safe guard and fasten it with one screw.

Ê Push the both power supply modules in the bays of PS cage until they engage (description see the operating manual).

Ê Install the traverse, the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85 et seq..

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85 et seq..

Page 80: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 81: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 81

12 Conversion from a floorstand model to a rack model

V CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

Figure 67: Removing the stabilizer

Ê Remove the two screws (1).

Ê Lift the server somewhat and remove the stabilizer.

I The stabilizer is no longer required.

Ê Open the server as described in the chapter “Preparation” on page 21 et seq..

1

1

Page 82: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

82 Options Guide TX200 S4

Conversion from a floorstand model to a rack model

Figure 68: Removing the front cover

Ê Release the three locks and open the front cover.

Ê Unhook the front cover at the other side and remove the front cover.

I The front cover is no longer required.

Ê Lay the server on its right-hand side. Get a second person to help you do this. The server can weigh up to 35 kg.

Page 83: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 83

Conversion from a floorstand model to a rack model

Figure 69: Position of the recesses

Ê Press the three hooks of the plastic front cover on the bottom side in the recesses (see the circles) of the housing.

Ê Press the plastic front cover onto the housing until the three tabs on the top side (see the circles) engage.

Figure 70: Installed plastic front cover

Ê Open the server as described in the chapter “Completion” on page 85 et seq..

Page 84: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

84 Options Guide TX200 S4

Conversion from a floorstand model to a rack model

Ê Install the rack model in the rack as described in the operating manual.

To enable the rack model to be presented correctly in ServerView, proceed as follows:

Ê Boot the system from the ServerStart DVD.

Ê Select your language in the first window, select „Status backup media - No status backup“ and click „Continue“.

Ê Read the terms of license and accept them.

Ê Continue with the Guided/Expert mode.

Ê Select “Tools - System Configuration Utilities - SCU Chassis Model Conversion“ and convert the server type to rack mounted.

Page 85: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 85

13 CompletionV CAUTION!

Follow the safety instructions in chapter “Safety instructions” on page 15 et seq..

13.1 System fans and traverse

13.1.1 Installing the system fan 3

Figure 71: Installing the system fan 3

Ê Put the hooks of the system fan 3 into the recesses on the server’s rear side (1).

Ê Push the system fan 3 in direction of the arrow until the lock engages (2).

Ê Connect the fan cable to the connector FAN3 SYS on the system board.

2

1

Page 86: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

86 Options Guide TX200 S4

System fans and traverse Completion

13.1.2 Installing the traverse with the air duct over the main memory

Ê Install the system fan 3 before.

Figure 72: Installing the traverse

Ê Insert carefully the traverse with the air duct over the main memory.

Ê Hook the traverse in place (1).

Ê Press on the traverse (2) until the lock (a) engages.

13.1.3 Installing the system fan 2

Ê Install the system fan 3 and the traverse before.

Figure 73: Installing the system fan 2

Ê Hook the system fan into the traverse (1) and press it in the housing until the lock engages (2).

2a

1

2

1

Page 87: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 87

Completion System fans and traverse

Ê Connect the fan cable to the connector FAN2 SYS on the system board.

13.1.4 Installing the system fan 1

Ê Install the system fan 3, the traverse and the system fan 2 before.

Ê Connect the fan cable to the connector FAN1 SYS on the system board.

Figure 74: Installing the system fan 1 (1)

Ê Insert carefully the air duct with the integrated system fan 1.

Refer also to the four bolts on the traverse and the housing of the power supply unit (see the circles).

1

Page 88: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

88 Options Guide TX200 S4

System fans and traverse Completion

Figure 75: Installing the system fan 2 (1)

Ê Push the air duct in direction of the arrow (2).

Make sure that the lock (a) engages.

a

2

Page 89: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 89

Completion Floorstand model

13.2 Floorstand model

13.2.1 Closing the server

Ê Open the latch.

Figure 76: Attaching the left-hand side cover

Ê Position the left-hand side cover in the five recesses (see circles) of the housing (1).

Ê Push the left-hand side cover against the housing and push down the latch (2) at the same time.

Closing the latch pushes the left-hand side cover to the front side and the hooks on the upper cant of the left-hand side cover engage.

Ê Insert the key.

Ê Lock the server.

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

2

1

Page 90: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

90 Options Guide TX200 S4

Rack model Completion

13.3 Rack model

13.3.1 Closing the server

Ê Open the latch.

Ê Position the top cover in the five recesses of the housing (see also the figure 76 on page 89).

Ê Push the top cover against the housing and push down the latch at the same time.

Closing the latch pushes the top cover to the front side and the hooks on the right-hand side cant of the top cover engage.

If you have not removed the server from the rack cabinet, please skip this step:

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Do not use the handles on the rack front cover to lift the server into the rack.

Ê Lower the server from above onto the rails.

Figure 77: Installing the server in a rack cabinet

Ê Push the server as far as it will go into the rack (1).

Ê Fasten the server in the rack using the two knurled screws (2).

1

2

1

2

Page 91: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 91

Completion Rack model

If you have not removed the server from the rack cabinet, please skip this step:

Figure 78: Fastening the server in the rack cabinet at the rear side

Ê Fasten the rack unit at the rear side with two screws (1+2) on the left and the right side.

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

1

2

Page 92: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 93: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 93

14 Appendix

14.1 Cabling

You will find suggestions for cabling on the next pages.

Page 94: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

94 Options Guide TX200 S4

Cabling Appendix

Figure 79: Red. PS, 3.5“ HD, USB, SATA, slimline drive

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3A

3C

40

08

91

97

FAN 4 SYSFAN 3 SYS

Y3925-V301 / A3C40087205

Y3973-V2 / A3C40073691

Page 95: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 95

Appendix Cabling

Figure 80: Red. PS, 2.5“ HD, 2.5“ hard disks extension box, SATA

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

FA

N2

SY

S

5

2.5

“S

AS

HD

D4

2.5

“S

AS

HD

D5

2.5

“S

AS

HD

D6

2.5

“S

AS

HD

D7

X1

X6

X1

X6

Y2

19

3-V

11

1P

2

P4

Y2

19

3-V

11

1

P7

P6

P8

Y3963-V103 / A3C40089197

Y3963-V103

Y3963-V102

SA

TA

DV

D-R

om

X1

Fo

rm

odula

rR

AID

use

Y3

96

9-V

20

1

Fro

nt

vie

wH

DD

0-3

left

Fro

nt

vie

w(f

loo

rsta

nd)

HD

D0

-3 le

ft

Fro

nt

vie

wH

DD

4-7

rig

ht

Fro

nt

vie

w H

DD

4-7

ri

gh

t

Y3969-V201 / A3C40091986

A3C40086493 A3C40086493A3C40086493

Y3963-V102 / A3C40087289Y3952-V2 /

A3C40087925

Page 96: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

96 Options Guide TX200 S4

Cabling Appendix

Figure 81: Standard PS, 3.5“ HD, USB, SATA, slimline drive

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3A

3C

40

08

91

97

Y3973-V2 / A3C40073691

Page 97: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 97

Appendix Cabling

Figure 82: Standard PS, 3.5“ HD, SATA

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3A

3C

40

08

91

97

P6

P1

8

P1

6P

15

P1

7P

7P

8P

9P

12

Page 98: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

98 Options Guide TX200 S4

Cabling Appendix

Figure 83: Standard PS, 2.5“ HD, 2.5“ hard disks extension box, SATA

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

FA

N2

SY

S5

Fro

nt

vie

w H

DD

4-7

ri

gh

t

P1

4

Y2

19

3-

V1

11

P1

9

P2

Y2

19

3-

V1

11

P1

8

P1

6P

15

P1

7

P3

Y2

19

3-

V1

11

Y2

19

3-

V1

11

P6

P7

P8

P9

P1

2

P5

P4

Page 99: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 99

Appendix Cabling

Figure 84: Standard PS, 3.5“ HD, SCSI, SATA, LSP

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

98

0-V

11

/ A

3C

40

08

076

5

SA

TA

/ D

VD

0.5

Frontpanel

Y3925-V301 / A3C40087205

LS

P (

CS

S m

od

ule

) /

optio

na

l

Page 100: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

100 Options Guide TX200 S4

Cabling Appendix

Figure 85: Standard PS, 3.5“ HD, 3.5“ hard disks extension box, slimline drive, LSP, BBU

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3/

A3

C4

00

891

97

BBU

A3C40080521

BB

U

Y3

99

0-V

1

Y3969-V201 / A3C40091986

P6

P7

P8

P9

X1

X5

P4

P5

Y3

96

3-V

20

2/

A

3C

40

089

270

X1

Y3925-V301 / A3C40087205

Frontpanel

Y3

98

7-V

2/

A3

C4

00

90

454

Intr

.

Page 101: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 101

AbbreviationsAC

Alternating Current

ANSIAmerican National Standards Institute

ASR&RAutomatic Server Reconfiguration and Restart

BIOSBasic Input-Output System

BMCBaseboard Management Controller

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

DCDirect Current

Page 102: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

102 Options Guide TX200 S4

Abbreviations

DIMMDual Inline Memory Module

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCError Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EGBElectrostatic Sensitive Devices

EMPEmergency Management Port

EPPEnhanced Parallel Port

EMVElektromagnetische Verträglichkeit (electromagnetic compatibility)

FPCFront Panel Controller

FRUField Replaceable Unit

FSBFront Side Bus

Page 103: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 103

Abbreviations

GAMGlobal Array Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntegrated Drive Electronics

IOOPIntelligent Organization of PCI

iRMCintegrated Remote Management Controller

IRQInterrupt Request Line

LANLocal Area Network

LBALogical Block Address

Page 104: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

104 Options Guide TX200 S4

Abbreviations

LCDLiquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

LWLOptical Waveguide

MMFMulti Mode Faser

MRLManual Retention Latch

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analyzing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

RAMRandom Access Memory

Page 105: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 105

Abbreviations

ROMRead-Only Memory

RSBRemote Service Board

RTCReal Time Clock

RTDSRemote Test and Diagnosis System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SASSerial Attached SCSI

SATASerial ATA

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

SELSystem Event Log

SMISystem Management Interrupt

Page 106: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

106 Options Guide TX200 S4

Abbreviations

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

USBUniversal Serial Bus

VGAVideo Graphics Adapter

ZCRZero Channel RAID

Page 107: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

TX200 S4 Options Guide 107

IndexAaccessible drives 9, 39

BBBU 61

Cconversion of floorstand model to rack

model 10, 81conversion standard PS to hot-plug

PS 10, 69

Ddual operation 31, 35

Eelectrostatic-sensitive devices

(ESD) 19ESD (electrostatic-sensitive

devices) 19expansion card 10, 57

Hhard disks extension box 9heat sink 37

Iinformation material, additional 8

Llaser information 19light emitting diode (LED) 19lithium battery 18

Mmain memory 9, 27meaning of the symbols 11multi-processor operating

system 31, 35

Nnotational conventions 11

Pparallel interface 10, 67Performance Adapter 10, 64processor 9, 31

RRAID key 65

SServerView Local Service Panel 9,

46

Ttarget group 7

Uupgrade standard system fan to red-

undant system fans 10, 69

Page 108: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server
Page 109: PRIMERGY TX200 S4 Server - Fujitsu Technology Solutionsmanuals.ts.fujitsu.com/file/4151/tx200s4-og-en.pdf ·  · 2011-10-06Edition April 2008. ... – “PRIMERGY TX200 S4 Server

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009