Primergy PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystem Günter Benkelberg Fujitsu Siemens Computers GmbH cognitas PS 81730 München e-mail: Internet:[email protected] Tel.: 0 52 51 / 8 - 1 48 91 Fax: (++49) 700 / 372 00000 U41181-J-Z156-3-74 Sprachen: En Edition November 2002

PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Embed Size (px)

Citation preview

Page 1: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Primergy

PRIMERGY SX10 / PRIMEPOWER BG57Storage Subsystem

Günter BenkelbergFujitsu Siemens Computers GmbH cognitas PS81730 Münchene-mail: Internet:[email protected].: 0 52 51 / 8 - 1 48 91Fax: (++49) 700 / 372 00000U41181-J-Z156-3-74Sprachen: En

Edition November 2002

Page 2: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Comments… Suggestions… Corrections…The User Documentation Department would like to know your opinion on this manual. Your feedback helps us to optimize our documentation to suit your individual needs.

Fax forms for sending us your comments are included at the back of the manual.

There you will also find the addresses of the relevant User Documentation Department

Copyright and Trademarks

Copyright © 2002 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

This manual is printed on paper treated with chlorine-free bleach.

Page 3: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Introduction

Important Notes

Installation

Preparation for Use and Operation

Troubleshooting

Related Publications and Index

Page 4: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER
Page 5: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.2 Notational Conventions . . . . . . . . . . . . . . . . . . . . . . 31.3 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . 72.1 Notes on Safety . . . . . . . . . . . . . . . . . . . . . . . . . . 72.2 Electrostatic-Sensitive Component Label . . . . . . . . . . . . . 92.3 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 102.4 RFI Suppression . . . . . . . . . . . . . . . . . . . . . . . . . 102.5 Notes on Mounting in the Rack . . . . . . . . . . . . . . . . . 102.6 Notes on Transportation . . . . . . . . . . . . . . . . . . . . . 112.7 Environmental Protection . . . . . . . . . . . . . . . . . . . . 11

3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 133.1 Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . 133.2 Unpacking the Storage Subsystem . . . . . . . . . . . . . . . 143.3 Installing and Uninstalling the Storage Subsystem

in and from the Rack . . . . . . . . . . . . . . . . . . . . . . . 153.4 Requirements of the Rack . . . . . . . . . . . . . . . . . . . . 153.5 Installing in the PRIMECENTER Rack . . . . . . . . . . . . . 193.6 Installing in the DataCenter Rack . . . . . . . . . . . . . . . . 223.7 Installing in the Classic Rack . . . . . . . . . . . . . . . . . . 223.8 Installing in 3rd-Party Racks . . . . . . . . . . . . . . . . . . . 223.9 Installing the Server . . . . . . . . . . . . . . . . . . . . . . . 233.10 Setting the SCSI ID . . . . . . . . . . . . . . . . . . . . . . . 243.11 Connecting the Storage Subsystem . . . . . . . . . . . . . . . 253.11.1 Connecting SCSI Cables . . . . . . . . . . . . . . . . . . . . 263.11.2 Connecting the Power Cable . . . . . . . . . . . . . . . . . . 273.12 Connecting and Disconnecting Cables . . . . . . . . . . . . . 28

4 Preparation for Use and Operation . . . . . . . . . . . . . . 294.1 Display Components . . . . . . . . . . . . . . . . . . . . . . . 294.2 Controls for Switching on/off the Storage Subsystem . . . . . . 304.3 Alarm Function . . . . . . . . . . . . . . . . . . . . . . . . . . 31

U41181-J-Z156-3-74

Page 6: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Contents

5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . 335.1 Opening the Storage Subsystem Housing . . . . . . . . . . . . 335.2 Storage Subsystem Cannot be Switched on . . . . . . . . . . . 355.3 SCSI Devices are not Detected . . . . . . . . . . . . . . . . . . 355.4 Incorrect SCSI ID . . . . . . . . . . . . . . . . . . . . . . . . . 355.5 Fan Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365.6 Replacing the Backup Unit . . . . . . . . . . . . . . . . . . . . 36

Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

U41181-J-Z156-3-74

Page 7: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

1 IntroductionThe demand for scalable storage capacity and the increasing trend towards rack-based servers have generated a need for correspondingly compact and powerful backup systems that can guarantee the necessary data security.

Figure 1: The PRIMERGY SX10 / PRIMEPOWER BG57storage subsystem

The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem provides a flexible means of consolidating rack-based data security. The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem makes it possible to install present-day backup units (such as DLT 8000, LTO, DDS4, Autoloader, etc.) in a separate 19” cabinet and provides two 3.2”-high or four 1.6”-high slots for this purpose. The storage subsystem is also ready to accommodate future backup units.

The storage subsystem offers a simple, flexible and low-priced solution for avoiding backup constraints and enabling expansion.

The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem can be connected via onboard controllers or SCSI host bus adapters and has been equipped with an LVD interface module for this purpose.

U41181-J-Z156-3-74 1

Page 8: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Target Group Introduction

The interface module accommodates the logic for controlling the power supply and monitoring the fan. It also establishes a connection between the external and internal cabling.

The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem is cooled by a fan. The fan is monitored to make sure it does not fall below the nominal speed.

The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem possesses an integrated power supply unit.

The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem occupies three height units (3 HU) in the 19” rack.

1.1 Target Group

This manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. The operating manual contains all the information required for installing and operating your system.

Knowledge of the hardware and data transfer as well as a basic knowledge of the operating system used is required to understand the various expansion options.

2 U41181-J-Z156-3-74

Page 9: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Introduction Notational Conventions

1.2 Notational Conventions

1.3 Technical Data

Text in italics indicate commands and input in the main body of text

"Quotation marks" indicate references to other chapters or manuals

Ê Text following this symbol describes activities that must be performed in the order shown

I This symbol is followed by supplementary information, remarks and tips

V Pay particular attention to texts marked with this symbol. Failure to observe this warning endangers your life, destroys the system, or may lead to loss of data.

Table 1: Notational conventions

Electrical data power supply unit

Rated voltage 100 V-125 V / 200 V-240 V

Tolerance of the rated voltage +6% / -10%

Rated frequency 50 Hz / 60 Hz

Max. rated current 240 V / 2.0 A 100 V / 4.0 A

Max. apparent power (heat transfer) 200 W

Effective power of typical peripheral devices

(the actual effective power will depend on the number and type of peripheral devices installed)

DLT8000 39 W

LTO 50 W

SLR100 23.1 W

Mammoth 18 W

U41181-J-Z156-3-74 3

Page 10: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Technical Data Introduction

Magneto Optical Disk 15 W

Dimensions and weight

Height (mm) 132.35

Width (mm) 482.6

Rack space requirement (mm) 445

Rack height units 3 height units (U)

Rack cable space (mm) 100

Depth (mm) 485

Weight (kg) approx. 9.2 (depending on configu-ration)

Environmental conditions (according to DIN EN 60721-3-x)

Climate/operation (class 3K3):

Temperature (°C) 15 to 35

Relative humidity (%) 5 to 85

Climate/transport (class 2K2):

Temperature (°C) -25 to 60

Relative humidity (%) 15 to 98

Mechanical environmental conditions

Operation class 3M2

Transport class 2M1

Standards complied with

Product safety and ergonomics IEC 60950 (DIN EN 60950), UL 1950, CSA 22.2 No. 950

Electromagnetic compatibility

Emitted interference EN 55022, class B; FCC part 15, class B

Noise immunity EN 50024

Effective power of typical peripheral devices

4 U41181-J-Z156-3-74

Page 11: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Introduction Technical Data

FCC verification Class B

VCCI verification Class B

CE label EMC guideline 89/339/EEC;EN 61000-3-2; EN 61000-3-3

Product safety 73/23/EEC

Approval certification GS, CSA US/C, CB certificate

Noise development (ISO 9296) Operation

Workstation-relatedsound pressure level (LpAm)

max. 56 dB(A)

Maintenance areas and ventilation distances

Specified by the rack

U41181-J-Z156-3-74 5

Page 12: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER
Page 13: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

2 Important Notes

2.1 Notes on Safety

In this section you will find information that you must note when using the storage subsystem.

This device complies with the relevant safety standards for IT equipment, including electronic office machines, intended for use in the office environment.

I You will also find the following safety instructions in the manual entitled “Safety, Guarantee and Ergonomics“, which also includes other notes on guarantee and ergonomics. Also pay attention to the notes in the manual for the connected PRIMERGY system.

If you have any questions relating to setting up and operating your system in the environment where you intend to use it, please consult our service organization.

V ● The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.

● Transport the device in its original packaging or in other suitable packaging, which will protect it against shock or impact.

● Read the notes on environmental conditions in the section “Technical Data” on page 3 before setting up and operating the device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

U41181-J-Z156-3-74 7

Page 14: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Notes on Safety Important Notes

V ● Check that the rated voltage specified on the device’s ID plate is the same as the local line voltage.

● The device must only be connected to a properly grounded wall outlet (the device is fitted with a tested and approved power cable).

● Make sure that the protective grounded outlet of the building’s wiring system is freely accessible.

● Before opening the unit, switch off the device and then pull out the power plugs.

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

● The system unit and the directly connected external storage subsystems should be connected to the same power supply distributor. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the storage subsystem has failed during a power failure.

● Make sure that no objects (such as jewelry or paper clips) or liquids fall or spill into the device (risk of electric shock or short circuit).

● In emergencies (e.g. damage to housing, power cords or controls or ingress of liquids or foreign bodies), immediately power down the device, pull out the power plugs and notify your service department.

● Note that proper operation of the system (in accordance with IEC 60950/DIN EN 60950) is guaranteed only if slot covers are installed on all vacant slots and/or dummies on all vacant bays and the housing cover is fitted (cooling, fire protection, RFI suppression).

8 U41181-J-Z156-3-74

Page 15: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Important Notes Electrostatic-Sensitive Component Label

2.2 Electrostatic-Sensitive Component Label

Components that are sensitive to electrostatic-sensitive discharge (ESD) may be identified by the following sticker:

Figure 2: Electrostatic-sensitive component sticker

You must follow the instructions below when handling modules containing electrostatic-sensitive components:

Ê Discharge static electricity from your body (for example by touching a grounded metal object) before handling modules containing electrostatic-sensitive components.

Ê The equipment and tools you use must be free of static charge.

Ê Remove the power plug before installing or removing modules containing electrostatic-sensitive components.

Ê Only hold modules containing electrostatic-sensitive components by their edges.

Ê Do not touch any of the pins or track conductors on a module containing electrostatic-sensitive components.

Ê Use a specially designed grounding strap to connect you to the system unit as you install the modules.

Ê Place all components on a static-safe base.

I A full description of the handling of modules containing electrostatic-sensitive components can be found in “Guidelines on handling electro-static sensitive devices and modules (ESD)” or “ITS Circular 4/95”.

I An EGB kit can be ordered from sales or from an authorized speciality store under the order number 8501 and part number 06431046.

U41181-J-Z156-3-74 9

Page 16: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

CE Certificate Important Notes

2.3 CE Certificate

2.4 RFI Suppression

All other equipment that is connected to this product must also have radio noise suppression in accordance with EC Guideline 89/336/EEC.

Products that meet this requirement are accompanied by a certificate to that effect issued by the manufacturer and/or bear the CE mark. Products that do not meet this requirement may only be operated with the special permission of the BZT (Bundesamt für Zulassungen in der Telekommunikation).

2.5 Notes on Mounting in the Rack

● When connecting and disconnecting cables, observe the notes in the documentation for your PRIMERGY system and the comments in the chapter "Important notes" in the corresponding rack operating manual supplied with the rack.

● Ensure that the anti-tilt bracket is correctly mounted when you set up the rack.

● For safety reasons, no more than one unit may be withdrawn from the rack at any one time during installation and maintenance work.

● If more than one unit is withdrawn from the rack at any one time, there is a danger that the rack will tilt forward.

● The power supply to the rack must be installed by an authorized specialist (electrician).

The shipped version of this device complies with the require-ments of the EEC directives 89/336/EEC "Electromagnetic compatibility" and 73/23/EEC "Low voltage directive". The device therefore qualifies for the CE certificate (CE=Communauté Européenne).

10 U41181-J-Z156-3-74

Page 17: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Important Notes Notes on Transportation

2.6 Notes on Transportation

I Transport the storage subsystem in its original packaging or in other suitable packaging that will protect it against shock or impact.Do not unpack it until all transport maneuvers are completed.

If you need to lift or transport the storage subsystem, ask someone to help you if necessary.

2.7 Environmental Protection

Environmentally Friendly Product Design and Development

This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and devel-opment”.

This means that the designers have taken into account important criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.

This saves resources and thus reduces the harm done to the environment.

Notes on Saving Energy

Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work.

Notes on Packaging

We recommend that you do not throw away the original packaging in case you need it later for transportation. If possible, devices should be transported in their original packaging.

Notes on Dealing with Consumables

Plesae dispose batteries in accordance with local government regulations.

U41181-J-Z156-3-74 11

Page 18: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Environmental Protection Important Notes

Notes on Labeling Plastic Housing Parts

Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them.

Take-Back, Recycling and Disposal

For details on take-back and reuse of devices and consumables within Europe, contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling center in Paderborn:

Fujitsu Siemens Computers GmbHRecycling CenterD-33106 Paderborn

Tel. ++49 5251 8180-10

Fax ++49 5251 8180-15

Further Information on Environmental Protection

The Fujitsu Siemens Computers GmbH representative for environmental protection will be happy to answer any further questions you may have concerning environmental protection.

Fujitsu Siemens Computers GmbHReferat UmweltschutzWerner-von-Siemens-Straße 6D-86159 Augsburg

Tel. +49 821 804-2386

Fax +49 821 804-2706

12 U41181-J-Z156-3-74

Page 19: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

3 Installation

3.1 Installation Steps

V Please take note of the safety information in the chapter “Important Notes” on page 7.

Do not expose the storage subsystem to extreme environmental condi-tions (see section “Technical Data” on page 3). Protect it from dust, humidity and heat.

Ê Unpack the storage subsystem (see next section “Unpacking the Storage Subsystem”).

Ê Mount the storage subsystem in the rack (see section “Installing and Uninstalling the Storage Subsystem in and from the Rack” on page 15).

Ê Set the SCSI bus addresses of the installed backup units (see section “Setting the SCSI ID” on page 24).

Ê Attach the cables according to the (rack) configuration required.

Ê Connect the storage subsystem to the power supply (see section “Connecting the Power Cable” on page 27).

Ê Start up the storage subsystem (see chapter “Preparation for Use and Operation” on page 29).

U41181-J-Z156-3-74 13

Page 20: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Unpacking the Storage Subsystem Installation

3.2 Unpacking the Storage Subsystem

V Please take note of the safety information in the chapter “Important Notes” on page 7.

Ask somebody for help with carrying the storage subsystem

It is recommended that you do not throw away the original packaging material! It may be required for transport at a later date.

Ê Unpack all the individual parts.

Ê Check the delivery for damage incurred during transport.

Ê Check whether the delivery matches the details on the delivery note.

Ê Check whether all necessary details have been entered on the first page of the guarantee coupon booklet.

Should you discover any damage caused during transport or notice that the delivery does not match the delivery note, notify your supplier immediately.

14 U41181-J-Z156-3-74

Page 21: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

InstallationInstalling and Uninstalling the Storage Subsystem in and from t

3.3 Installing and Uninstalling the Storage Subsystem in and from the Rack

V ● Please observe the safety precautions and references to mounting into the rack in chapter “Important Notes” on page 7.

● At least two people are needed to position the server in the rack.

● The rack can tip over if more than one unit is removed.

3.4 Requirements of the Rack

The rack systems of the Fujitsu Siemens Computers GmbH (19-Inch (Classic) Rack, DataCenter Rack and PRIMECENTER Rack) fully support the installation of the PRIMERGY server systems. The installation in rack systems of several other manufacturers (3rd-Party Rack) available at present is supported to a large part.

To accommodate the ventilation concept and ensure proper ventilation of the components in the rack, any unused areas must be closed using dummy covers.

Power is supplied via the socket strips available in the rack.

U41181-J-Z156-3-74 15

Page 22: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Requirements of the Rack Installation

The main features of the rack systems of the Fujitsu Siemens Computers GmbH are:

PRIMECENTER Rack

– Frontally bolted telescopic rails or sliding rails.

The assembly brackets and/or the sliding rails are provided with a linear alignment facility to ensure also an adjustment to different rack depths (except in the rear left area, where a support bracket is used).

– Extended cable management within the lateral rack area.

DataCenter Rack

– Frontally oraterally (using a grid) bolted telescopic rails or sliding rails (except within the rear left area, where a support bracket is used).

– Extended cable management within the lateral rack area.

19-Inch (Classic) Rack

– Laterally (using a grid) bolted telescopic rails or sliding rails.

The mounting of the telescopic rails and the assembly brackets in the different racks is described in the next sections.

The mounting of the cable management is described in detail in the Technical Manual for the respective rack.

16 U41181-J-Z156-3-74

Page 23: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installation Requirements of the Rack

3rd-Party Rack

The following general conditions apply to rack systems of several other manufacturers:

– Installation dimensions (see the dimensions shown in figure 3 on page 18).

– The operability of the server safety mechanisms, e.g. stoppers or holding back systems, must be guaranteed.

– The form of the rack support uprights must ensure the frontal screwing on of the telescope rails.

– Climatic conditions.An air intake unimpeded to a large extent in the rack front and an air discharge in the rear cover of the rack are necessary for the ventilation of the installed server.In principle, the ventilation concept envisages that the necessary cooling is reached by the horizontal self-ventilation of the installed devices (air flow from the front to the rear).

– Power supply.Presence of appropriate socket strips must be ensured for the installation in 3rd-Party Racks.

1 rack front side2 rack rear sideA rack depth (comparison PRIMECENTER Rack 940/1000 mm)B rack width (comparison PRIMECENTER Rack 700 mm)C clearance of the 19-inch installation levelC1 front 19-inch installation level

C2 rear 19-inch installation levelD area for cable routing (cable area depth) and ventilationE area for front panel and ventilationF right and left area for support systemsP PRIMERGY installation deptha1 front left support upright

a2 front right support uprightb1 rear left support uprightb2 rear right support upright

U41181-J-Z156-3-74 17

Page 24: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

18

U41

181-

J-Z

156-

3-74

Fig

ure

3:M

echa

nica

l con

ditio

ns

C (4

50 m

m +

1 )

B

-0

E

45 mm

1C1

Req

uir

emen

ts o

f th

e R

ack

Inst

alla

tion

710 - 815 mm

b2 a2

a1b1

2

D

min

. 15 m

m

F

F

C2

min. 100 mm

PRIMERGY

A

P

Page 25: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installation Installing in the PRIMECENTER Rack

3.5 Installing in the PRIMECENTER Rack

For installation in the PRIMECENTER Rack, the rack mounting kit delivered with the subsystem is used.

Figure 4: Rack mounting kit

Ê Install the support structure as shown in the figure.

S l i d i n g r a i lr e a r l e f t

S l i d i n g r a i lf r o n t l e f t

S l i d i n g r a i lf r o n t r i g h t

S l i d i n g r a i lr e a r r i g h t

T a p e t i t e I I M 4 s c r e w2

2

2

U41181-J-Z156-3-74 19

Page 26: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installing in the PRIMECENTER Rack Installation

Figure 5: Installing the support structure in the PRIMECENTER Rack

For mounting the left telescopic rail in the PRIMECENTER Rack, the delivered support bracket must first be mounted on the rear left support upright. The bracket must be mounted level with the lower edge of the device.

Ê Refer to the assembly instructions in the Technical Manual for the PRIME-CENTER Rack (see also “Related Publications” on page 39).

I For better orientation the height units are marked on the support uprights.

Ê Mount the support angle at the appropriate height on the left rear support upright as described in the Technical Manual of the PRIMECENTER Rack.

Ê Insert the support structure in the rack.

Ê Place the mounting springs in the appropriate holes of the support bracket or support upright at the marked attachment points and screw the support structure tight at the 19“ profiles on the front and the rear (see figure on page).

S u p p o r t b r a c k e t 1 H U

S l i d i n g r a i lr e a r l e f t

S l i d i n g r a i lf r o n t l e f t

S l i d i n g r a i lf r o n t r i g h t

S l i d i n g r a i lr e a r r i g h t

1 9 " m o u n t i n g s p r i n g

T a p e t i t e I I M 4 s c r e w

1

2

1

2

1

2

12

12

1 2

2

2

20 U41181-J-Z156-3-74

Page 27: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installation Installing in the PRIMECENTER Rack

Ê Also make sure that there is a length adjustment.

Ê Loosen the scews for the length adjustment slightly to ensure that the support structure is installed in the rack without too much tension.

Ê After this, fasten the screws again tightly.

I The maximal moment of fixation for the Tapetite II M4 screws is 170 Ncm.

Ê Place the cage nuts for fastening the front panel in the appropriate holes of the front support uprights.

Ê Insert the server and fasten it using the two knurled screws (section “Installing the Server” on page 23)

Ê Route the cables with the server inserted as described in the Technical Manual of the PRIMECENTER Rack.

Figure 6: Installing the sliding rails in the PRIMECENTER Rack

1

2

1 9 " m o u n t i n g s p r i n g

T a p e t i t e I I M 4 s c r e w

U41181-J-Z156-3-74 21

Page 28: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installing in the DataCenter Rack Installation

3.6 Installing in the DataCenter Rack

The installation in the DataCenter Rack is carried out in the same way as was described for the PRIMECENTER Rack.

3.7 Installing in the Classic Rack

To install the server in the Classic (19-inch) Rack, please use a sliding rail of the rack manufacturer.

The rack mounting kit delivered with the server cannot be used for this rack.

3.8 Installing in 3rd-Party Racks

If your rack matches the general conditions for 3rd-Party Racks, you can use parts of the rack mounting kit delivered with the server. The delivered support bracket and the cable management may not be required.

For installing the server in a 3rd-Party Rack the following parts from the rack mounting kit are required:

– Two telescopic rails (assembled)– Eight mounting springs with Tapetite II M4 screws.

Ê Refer to the original manual of the rack manufacturer regarding the mechanical installation and/or the climatic conditions.

V When installing the server installation in 3rd-Party Racks, make sure that there is air flow in the rack from the front to the rear.

I A number of parts of the delivered rack mounting kit may not be compatible, because original parts of the 3rd-Party Rack must to be used.

V Make sure that the server security mechanismus, e. g. stoppers and holding back systems, will function properly.

Ê Insert the server (see section “Installing the Server” on page 23).

Ê Route the cables as described in the original manual of the rack.

Ê Secure the server on the front panel using two knurled screws.

22 U41181-J-Z156-3-74

Page 29: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installation Installing the Server

3.9 Installing the Server

Install the support structure as described for the PRIMECENTER Rack.

The following steps can be performed by a single person:

Figure 7: Fastening the server

Ê Push the server into the rack as far as it will go (1).

Ê Secure the server within the rack using two knurled screws (2).

To uninstall the server, proceed in reverse order.

2

2

U41181-J-Z156-3-74 23

Page 30: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Setting the SCSI ID Installation

3.10 Setting the SCSI ID

Set the SCSI ID (bus address) using the coding jumpers of the installed backup unit involved.

The SCSI IDs must be unique (assigned only once in the SCSI string) and are freely selectable from SCSI ID 0 to SCSI ID 6 (SCSI ID 7 is always used by the host adapter).

I There is an adhesive device label on the back of the storage subsystem. Enter the device type name and the SCSI ID of the installed backup units on this label.

This makes it easier to identify the backup units.

Figure 8: Adhesive device label

24 U41181-J-Z156-3-74

Page 31: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installation Connecting the Storage Subsystem

3.11 Connecting the Storage Subsystem

The ports are on the rear of the storage subsystem.

Figure 9: Ports on PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem

(1) Voltage switch 115 V/230 V

(2) 4 x SCSI storage subsystem ports: 68-pin SCSI connector

(3) Insulated connector

1 2

3

U41181-J-Z156-3-74 25

Page 32: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Connecting the Storage Subsystem Installation

3.11.1 Connecting SCSI Cables

Ê Switch off the CPU.

Ê You can assign up to four 68-pin SCSI ports on your storage subsystem but you must make sure that Channels A through D are assigned in the correct order.

Figure 10: SCSI ports

26 U41181-J-Z156-3-74

Page 33: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Installation Connecting the Storage Subsystem

3.11.2 Connecting the Power Cable

Ê Set the voltage to the desired voltage range (115 V or 230 V) using the voltage switch (1) on the back of the storage subsystem.

Ê Connect the power cable of the storage subsystem to a free insulated socket on the grounded connector strip in the rack (see the Technical Manual for the rack).

Figure 11: Insulated connector

1

U41181-J-Z156-3-74 27

Page 34: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Connecting and Disconnecting Cables Installation

3.12 Connecting and Disconnecting Cables

V The power plug must be pulled out.Never connect or disconnect cables during thunderstorms.When disconnecting a cable, always take hold of the plug. Never pull on the cable.

Connecting Cables

Connect the cables in the sequence shown below:

● Switch off all affected devices.

● Unplug all affected devices from the power supply.

Ê Mark the cables and make a note of the function of each cable. Above all, observe the safety notes in the chapter “Important Notes” on page 7.

Ê Plug all power cables into the correctly fused and grounded power outlets.

Ê If the devices have an articulated cable guide, secure the cables to the artic-ulated cable guide with the cable ties.

Disconnecting Cables

Disconnect the cables in the sequence shown below:

Ê Switch off all affected devices.

Ê Unplug all affected devices from the power supply.

Ê Disconnect all cables on the server and the storage subsystem.

28 U41181-J-Z156-3-74

Page 35: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

4 Preparation for Use and Operation

4.1 Display Components

Two LED displays are installed on the front of the unit, one indicating the status of the power supply and the other indicating the status of the fans in the storage subsystem.

Figure 12: Display components on the front of the PRIMERGY SX10 / PRIMEPOWER BG57 subsystem

The bicolor power LED indicates the status of the power supply and the output voltage:

The bicolor fan LED indicates the status of the fan unit:

(1) Power LED (green): The power supply is switched on and is working properly.Power-LED (yellow): Standby mode, the power supply is switched off.

(2) Fan LED (green): The fans are working properly. The fan speed is within the permitted range.Fan LED (red): Fan failure. The fans are not working properly or the fan speed is below 1000 Upm.

1

2

U41181-J-Z156-3-74 29

Page 36: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Operating controls Preparations for use and operation

4.2 Controls for Switching on/off the Storage Subsystem

The Off/Local/Remote switch is located on the rear of the storage subsystem:

Figure 13: Controls on the rear of the PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem

If you encounter problems, check the connections to the system unit and possibly also the position of the “Local/Remote” switch (see also chapter “Troubleshooting” on page 33).

(1) In the Off (left setting) position, the storage subsystem is switched off.

(2) In the Remote (center setting) position, the storage subsystem is switched on and off from the system unit via TERMPWR.

(3) In the Local (right setting) position, the storage subsystem is switched on as soon as power is available, regardless of the operating status of the system unit.

1

2

30 U41181-J-Z156-3-74

Page 37: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Preparations for use and operation Alarm function

4.3 Alarm Function

If the fan falls below a defined speed, this error is indicated by an acoustic signal in addition to the lighting of the red LED on the front of the storage subsystem.

Figure 14: Alarm function

The acoustic signal can be activated and deactivated using the ALARM ON/OFF jumper.

The recorded error is deleted by briefly switching off the storage subsystem.

1

2

U41181-J-Z156-3-74 31

Page 38: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER
Page 39: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

5 Troubleshooting

5.1 Opening the Storage Subsystem Housing

Ê Switch off the connected system unit and disconnect the storage subsystem from the power supply by removing the power plug from the power outlet.

Ê Remove all the cables from the storage subsystem.

Ê Loosen the two fixing screws at the front of the storage subsystem, pull the storage subsystem from the rack and place it on a smooth surface.

Figure 15: Opening the housing

Ê Using a screwdriver, remove the four fixing screws on the rear of the storage subsystem.

U41181-J-Z156-3-74 33

Page 40: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Opening the Storage Subsystem Housing Troubleshooting

Figure 16: Opening the housing

Ê Lift up the device cover at the back until the fixing brackets (three to the top, right and left of the housing cover) are released and the housing cover can be removed easily.

Figure 17: Opening the housing

Make sure when closing the housing that the fixing brackets on the housing cover lock precisely into place.

34 U41181-J-Z156-3-74

Page 41: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Troubleshooting Storage Subsystem Cannot be Switched on

5.2 Storage Subsystem Cannot be Switched on

Ê Check the position of the “Off/Local/Remote” switch and, if necessary, move the switch to the “Remote” or “Local” position (see also section “Controls for Switching on/off the Storage Subsystem” on page 30).

Ê Check the connections to the system unit and the connection to the power supply.

Ê Boot the system unit again.

5.3 SCSI Devices are not Detected

If the storage subsystem is switched on late (e.g. by plugging in the power cord), it may mean that the SCSI devices are not detected when the system unit is booted.

Ê Check the connection to the power supply.

Ê Switch the system unit off and on again.

5.4 Incorrect SCSI ID

The backup unit does not respond with the SCSI ID noted on the label (on the back panel of the storage subsystem), or there is an address conflict on the SCSI bus:

Ê Check the address jumpers of the backup unit involved. Refer to the documentation for the backup unit for help.

The address jumpers of most of the backup units are located on the back of the device.

Ê Open the storage subsystem housing (see section “Opening the Storage Subsystem Housing” on page 33) and set the SCSI ID (see section “Setting the SCSI ID” on page 24).

U41181-J-Z156-3-74 35

Page 42: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Fan Failure Troubleshooting

5.5 Fan Failure

The fan unit for cooling the storage subsystem is connected to the interface board (4-pin connection). The fan is monitored to ensure it maintains the correct speed. A fan failure is reported as soon as the fan speed falls below 1000 rpm (+/- 20%).

Ê Check that the ventilation slots are not covered.

Ê Delete the recorded error by briefly switching off the storage subsystem.

If the error occurs again, contact your service partner.

5.6 Replacing the Backup Unit

The backup units are mounted on two frames within the storage subsystem. Two 1.6”-high or one 3.2”-high backup devices can be mounted in one frame. If you want to replace a backup unit, you must remove the frame together with the installed devices from the housing.

Ê Open the housing of the storage subsystem (see section “Opening the Storage Subsystem Housing” on page 33).

Ê Remove all the cables from the installed backup devices in the relevant frame.

36 U41181-J-Z156-3-74

Page 43: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Troubleshooting Replacing the Backup Unit

Figure 18: Releasing the mounting frame

Ê Release the mounting frame by removing it from its holders in the direction indicated.

Ê Remove the frame from the housing.

U41181-J-Z156-3-74 37

Page 44: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Replacing the Backup Unit Troubleshooting

Figure 19: Removing a backup unit

Ê Remove the screws and pull the defective unit from the frame.

To install a backup unit, you follow the same procedure in reverse order:

Ê Before you install the new backup unit, set the SCSI ID (see section “Setting the SCSI ID” on page 24).

I A flat cable is used for the internal SCSI cabling.

16- bit devices are connected directly, 8-bit devices require a 50-to-68-pin adapter. Mixed operation using both 8-bit and 16-bit devices is therefore possible.

38 U41181-J-Z156-3-74

Page 45: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Related PublicationsPlease apply to your local office for ordering the manuals.

[1] Safety, Guarantee and Ergonomics

[2] PRIMECENTER Rack-System für / Rack System for PRIMERGY, PRIMEPOWER, BS2000, STORAGE

[3] PRIMERGY DataCenter Rack

U41181-J-Z156-3-74 39

Page 46: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER
Page 47: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Index

"Local/Remote" switch 29

16-bit devices 3850-to-68-pin adapter 388-bit devices 38

Aadhesive labels on plastic housing

parts 12approval certification 5

Bbackup unit

replacing 36batteries,disposal 11

Ccables

connecting 28disconnecting 28

cage nut 20, 22CE label 5, 10clip

for telescopic rail 20, 21Consumables 11

Ddimension 4display components 29disposal of equipment 12

Eeffective power

peripheral devices 3electrical data 3electromagnetic compatibility 4, 10EMC guideline 5emitted interference 4environmental condition 4environmental protection 11

ergonomics 4

Ffan

failure 36frame 36

Hheight units 2, 20, 22housing 33housing cover 33

Llabel 24low voltage directive 10LVD interface module 2LVD/SE SCSI terminator 2

Mmaintenance area 5manufacturer’s notes 10mixed operation 38

Nnoise immunity 4noise level 5notational conventions 3

Ooperating components 29

Ppacking 11plastic housing parts, adhesive labels

12power connector 27product safety 4

Rrack assembly kit

mounting 22radio suppression 10

U41181-J-Z156-3-74 41

Page 48: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Index

recycling, equipment 12returning, equipment 12

Ssafety instructions 7saving energy 11SCSI ID 35, 38

setting 24server

height units 20, 22mounting rack assembly kit 22

spring nut 20standards, complied with 4support angle 20system port 26

Ttarget group 2technical data 3telescopic rail

clip 20, 21

Uunpacking 14

Vventilation 2ventilation distance 5

Wweight 4

42 U41181-J-Z156-3-74

Page 49: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Comments on PRIMERGY SX10 / PRIMEPOWER BG57Storage Subsystem

U41181-J-Z156-3-74

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation33094 PaderbornGermany

Fax: (++49) 700 / 372 00001

Internet: [email protected]://manuals.fujitsu-siemens.com

Page 50: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER
Page 51: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Comments on PRIMERGY SX10 / PRIMEPOWER BG57Storage Subsystem

U41181-J-Z156-3-74

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation33094 PaderbornGermany

Fax: (++49) 700 / 372 00001

Internet: [email protected]://manuals.fujitsu-siemens.com

Page 52: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER
Page 53: PRIMERGY SX10 / PRIMEPOWER BG57 Storage Subsystemmanuals.ts.fujitsu.com/file/4217/sx10-bg57-ba-en.pdf · The PRIMERGY SX10 / PRIMEPOWER BG57 storage subsystem ... SX10 / PRIMEPOWER

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009