PRIMERGY RX300 S3 Operating Manual Edition December 2006

PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

Embed Size (px)

Citation preview

Page 1: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

PRIMERGY RX300 S3 Operating Manual

Edition December 2006

Page 2: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Fax forms for sending us your comments are included inthe back of the manual.

There you will also find the addresses of the relevantUser Documentation Department.

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2006 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 3: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Overview of the Documentation . . . . . . . . . . . . . . . . 7

1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1.3 Notational Conventions . . . . . . . . . . . . . . . . . . . . 18

1.4 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . 18

2 Installation Steps: Overview . . . . . . . . . . . . . . . . . 21

3 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . 23

3.1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

3.2 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 29

3.3 Transporting the Server . . . . . . . . . . . . . . . . . . . . 30

3.4 Notes on Installing into the Rack . . . . . . . . . . . . . . . 30

3.5 Environment Protection . . . . . . . . . . . . . . . . . . . . 31

4 Hardware Installation . . . . . . . . . . . . . . . . . . . . . 33

4.1 Unpacking the Server . . . . . . . . . . . . . . . . . . . . . 34

4.2 Installing/Removing the Server into/from the Rack . . . . . 344.2.1 Mounting into the PRIMECENTER/DataCenter Rack . . . . . . 384.2.2 Mounting into 3rd-Party Racks . . . . . . . . . . . . . . . . . 414.2.3 Installing the Server . . . . . . . . . . . . . . . . . . . . . . . 42

4.3 Connecting Devices to Server . . . . . . . . . . . . . . . . 44

4.4 Connecting the Server to the Line Voltage . . . . . . . . . . 45

4.5 Instructions on Connecting and Disconnecting Cables . . 47

5 Preparation for Use and Operation . . . . . . . . . . . . . . 49

5.1 Operating and Indicator Elements . . . . . . . . . . . . . . 495.1.1 The Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Page 4: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

Operating manual RX300 S3

Contents

5.1.2 The Rear Side . . . . . . . . . . . . . . . . . . . . . . . . . . 545.1.3 Indicators on the hot-plug CPU and System Fans . . . . . . . 57

5.2 Switching the Server ON and OFF . . . . . . . . . . . . . . 58

5.3 Configuring the Server . . . . . . . . . . . . . . . . . . . . 605.3.1 Configuration with ServerStart . . . . . . . . . . . . . . . . . 605.3.2 Configuration without ServerStart . . . . . . . . . . . . . . . . 61

5.4 Starting up Hot-Plug PCI Slots . . . . . . . . . . . . . . . . 62

5.5 Cleaning the Server . . . . . . . . . . . . . . . . . . . . . . 63

6 Property and Data Protection . . . . . . . . . . . . . . . . . 65

6.1 BIOS Setup Security Functions . . . . . . . . . . . . . . . . 65

7 Troubleshooting and Tips . . . . . . . . . . . . . . . . . . . 67

7.1 Power-On Indicator Remains Dark . . . . . . . . . . . . . . 67

7.2 The Server switches itself OFF . . . . . . . . . . . . . . . . 68

7.3 The Monitor Remains Dark . . . . . . . . . . . . . . . . . . 68

7.4 Flickering Stripes Across the Monitor . . . . . . . . . . . . 69

7.5 No Monitor Display or the Display Drifts . . . . . . . . . . . 69

7.6 No Mouse Pointer Displayed on the Monitor . . . . . . . . . 69

7.7 The Floppy Disk Cannot be Read or Written . . . . . . . . . 70

7.8 Incorrect Time and/or Date . . . . . . . . . . . . . . . . . . 70

7.9 System Fails to Boot . . . . . . . . . . . . . . . . . . . . . . 70

7.10 Drives Are Reported as „Dead“ . . . . . . . . . . . . . . . . 71

7.11 Added Drive Reported Defective . . . . . . . . . . . . . . . 71

7.12 Hot-Plug PCI Error Indicator Lighting . . . . . . . . . . . . 72

7.13 Hot-Plug PCI Power Indicator not Lighting after Replacing the Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

7.14 Error Messages on the Monitor . . . . . . . . . . . . . . . . 73

8 Hot-plug Components . . . . . . . . . . . . . . . . . . . . . 75

8.1 Hot-plug Power Supply Units . . . . . . . . . . . . . . . . . 75

Page 5: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual

Contents

8.1.1 Removing the Dummy Module . . . . . . . . . . . . . . . . . 758.1.2 Adding a hot-plug Power Supply Unit . . . . . . . . . . . . . . 768.1.3 Replacing a Hot-plug Power Supply Unit . . . . . . . . . . . . 76

8.2 Hot-plug Hard Disk Drives . . . . . . . . . . . . . . . . . . . 778.2.1 Handling Hard Disk Drives/HDD Modules . . . . . . . . . . . . 778.2.2 Removing/installing the dummy module . . . . . . . . . . . . . 788.2.3 Installing/Removing HDD Module . . . . . . . . . . . . . . . . 808.2.4 Hot-swap for HDD Modules . . . . . . . . . . . . . . . . . . . 87

8.3 Replacing a Hot-plug Fan . . . . . . . . . . . . . . . . . . . 888.3.1 Replacing the Fan . . . . . . . . . . . . . . . . . . . . . . . . 89

8.4 Replacing hot-plug PCI Boards . . . . . . . . . . . . . . . . 908.4.1 Mounting the PCI board into the pull out aid . . . . . . . . . . 94

8.5 Opening/Closing the Housing . . . . . . . . . . . . . . . . . 95

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . 103

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Page 6: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error
Page 7: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 7

1 IntroductionThe PRIMERGY RX300 S3 server is an Intel-based server for mid-size networks and large companies. The server is suitable for use as a file server and also as an application, information or Internet server.

The PRIMERGY RX300 S3 server offers a high level of reliability and avail-ability through highly developed hardware and software components. These include hot-plug hard disk drive modules, redundant CPU fans, system fans and power supply units, and hot-plug PCI slots, the ServerView Suite server management software, „Prefailure Detection and Analysing“ (PDA) and „Automatic Server Reconfiguration and Restart“ (ASR&R).

Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the the lockable rack door.

The rack model occupies 2 height units (HU) in the rack.

1.1 Overview of the Documentation

I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the ServerView Suite delivered with each server system.

The PDF files for the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL: http://manuals.fujitsu-siemens.com (click industry standard server).

Concept and Target Group of this Manual

This operating manual describes how to install, how to operate and how to expand your server.

This operating manual is intended for those responsible for installing the hardware and operating the system. The manual contains all the information required for mounting and operating your PRIMERGY RX300 S3 .

Knowledge of hardware and data transmission is required, as well as basic knowledge of the operating system used.

Page 8: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

8 Operating manual RX300 S3

Overview of the Documentation Introduction

Additional server documentation

The PRIMERGY RX300 S3 documentation also includes:

– “Quick Start Hardware - PRIMERGY RX300 S3 ” (leaflet)– “Quick Start Software - PRIMERGY ServerView Suite” (leaflet)– “Warranty” manual (print version supplied with the system, PDF file available

on the ServerBooks DVD supplied)– “Safety notes and other important information” manual (print version

supplied with the system, PDF file available on the ServerBooks DVD supplied)

– “Ergonomics” manual (PDF file available on the ServerBooks DVD supplied)– “Returning used devices” manual (PDF file available on the ServerBooks DVD

supplied)– “Helpdesk” (leaflet with worldwide helpdesk telephone numbers)– Technical Manual for the D2119 system board (PDF file available on the

ServerBooks DVD supplied)– “BIOS Setup” (PDF file available on the ServerBooks DVD supplied)– “PRIMERGY RX300 S3 Server Options Guide” (PDF file available on

the ServerBooks DVD)

I The “Options Guide” describes the server expansion and modifi-cation options.

– “ServerView Suite” includes the ServerStart Disc 1, the ServerStart Disc 2 and the ServerBooks DVD. The PDF version of the “PRIMERGY ServerView Suite - ServerStart” user manual is also available on the ServerBooks DVD.

I If you need a replacement copy of the -ServerBooks DVD, send the details of your sever to the following e-mail address: [email protected]

– “Global Array Manager Client Software User’s Guide” (PDF file available on the ServerBooks DVD)

– “Global Array Manager Server Software User’s Guide” (PDF file available on the ServerBooks DVD)

– “Integrated Mirroring User’s Guide” (PDF file available on the ServerBooks DVD)

I If you need a backup of the ServerBooks-DVD send the details of your server via email address: [email protected].

Page 9: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 9

Introduction Features

Further sources of information

– technical manual for the rack– manual for the monitor– server management manual ServerView– manual for the Remote Test and Diagnostic System RemoteView– in the documentation for the boards and drives– operating system documentation– information files of your operating system

(see also “Related Publications” on page 103).

1.2 Features

System board

The features of the system board (D2119 are described in the technical manual for the system board in relation to the hardware and in the BIOS setup manual (see “Related Publications” on page 103).

Slots for additional boards

There are up to fife extension slots for additional controller boards on the system board of the server:

Figure 1: PCI slots: basic configuration

LAN 1 LAN 2+

Page 10: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

10 Operating manual RX300 S3

Features Introduction

* The hot-plug functionality are indicated by two LEDs (6 and 7) on each slot (see section “The Rear Side” on page 56).

Pos. Slot No. Type Features PCI-Board

1 1standard

PCI X64 bit/133 MHz

low-profile

2 2

3 3hot-plug * PCI express x4

4 4

5 5 standard PCI express x8

Table 1: PCI slots: basic configuration

Page 11: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 11

Introduction Features

Optionally the possibility exists to install full height PCI boards only. In this case three standard slots via a 3-way riser card are available:

Figure 2: PCI slots: optional configuration

Hard disk drives

The server provides two drive cages for one of the following hard disk drive configurations:

that can accommodate

● 3.5-inch SAS/SATA hard disk drives: up to six (2x3) hard disk drive modules (HDD modules), each accomodating one 3.5-inch SAS/SATA hard disk drive with a maximum height of 1 inch

● 2.5-inch SAS hard disk drives: up to twelf (2x6) HDD modules, each accomodating one 2.5-inch SAS hard disk drive with a maximum height of 15 mm

The module is connected to the SAS/SATA backplane without cables. This allows hard disk drive modules to be simply plugged in or pulled out (for further details see section “Hot-plug Hard Disk Drives” on page 77).

The hard disk drive system is designed for SAS/SATA with a seperate channel for each of the hard disk drives.

Pos. Slot No.

Type Features PCI board

1 6

standard 64 bit/133 MHz

short, full height2 7

3 8 full length, full height

Table 2: PCI slots: optional configuration

LAN 1 LAN 2+

Page 12: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

12 Operating manual RX300 S3

Features Introduction

If the server has a corresponding RAID configuration, defective HDD modules can also be exchanged online (hot-swap).

Onboard SAS controller with IME functionality

For operating internal hard disk drives the SAS controller with Integrated Mirroring Enhanced functionality is available. Integrated Mirroring Enhanced offers additionally RAID 0,1 functionality for the internal disk configuration (IME level 1).

I To configure Integrated Mirroring Enhanced the controller has its own RAID-Select Utility. For further information see “Integrated Mirroring User’s Guide“ on the ServerBooks DVD (choose Controllers from the menu).

Onboard RAID5 processor

The RAID functionality of the onboard SAS controller can be upgraded: The RX300 S3 comes with an onboard RAID5 processor which can be activitated via an optional upgrading kit (SAS MegaRAID PCI Express). RAID level 0, 1, 10, 5 and 50 are supported. You find further information in the Options Guide (see “Related Publications” on page 103).

Accessible drives / components

Various mounting locations are available:

– one location for a 3.5 inch slimline 1.44 MB floppy disk drive (optionally) or for a LocalView module (optionally)

– one location for a slimline DVD-/DVD-ROM drive (optionally)

The accessible drives integrated in this locations cannot be replaced online.

A USB tape drive can be installed optionally in the left drive cage (see also the configurator under “Related Publications” on page 103). As a result, two mounting locations are occupied in the drive cage:

I – In case of 3.5-inch HDD configurations these mounting locations are no longer available for HDD modules.

The magnetic tape drive cannot be replaced online.

Page 13: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 13

Introduction Features

USB interface

The two USB interfaces on the front of the server supports activities carried out by the service technician. The maximum length of the external cable are three meters.

Power supply

In its basic configuration, the server has a hot-plug multi-range power supply unit that adjusts automatically to any power voltage in the range from 100 V - 240 V. An additional power supply unit can be installed optionally in order to ensure redundancy of the power supply. If one power supply unit fails, the redundant configuration ensures operation can continue uninterrupted. The defective power supply unit can be replaced online (for further details see section “Hot-plug Power Supply Units” on page 75).

Ventilation

The server is cooled by one or two fan units (redundant configuration). One fan unit with three CPU fans and one system fan is integrated in the standard system fan configuration. If two fan units are installed, each of them form a redundant unit.

If one fan in one redundant unit fails, the other fan unit ensures operation can continue uninterrupted. The defective fan can be replaced online (for further details see section “Replacing a Hot-plug Fan” on page 88).

Every processor has a heatpipe. The processors are cooled additionally by the three and/or six CPU fans in the fan units.

High level of availability and reliability

When memory data is accessed, 1-bit errors in the main memory are recog-nized and automatically corrected with the ECC (Error Correcting Code) method. The patented memory scrubbing function regularly starts up the EDC mechanism and thus ensures continuous data integrity.

The memory modules used support SDDC technology (Chipkill™), which in addition increases the effectiveness of the monitoring and correction of memory errors.

Support is likewise provided for hot-spare memory technology, in which a memory bank is used like a replacement bank. If a memory module fails, the bank with the defective memory is automatically deactivated and the replacement bank is activated in its place (assuming it has been configured

Page 14: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

14 Operating manual RX300 S3

Features Introduction

appropriately in the BIOS; see BIOS Setup under “Related Publications” on page 103). The deactivated memory bank is no longer used and the faulty memory module can be replaced at the next opportunity. In order to be able to use the hot-spare memory function, all occupied memory banks must have an identical memory configuration.

ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the case of an error and automatically „hides“ the defective system components.

The PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers analyzes and monitors all components important for system reliability.

Optional RAID functionality of the onboard SAS controller supports RAID Levels 0, 1, 10, 5 and 50 and increase system availability.

The hot-plug HDD modules provide additional availability.

Server management

Server management is implemented with the aid of the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens Computers. PDA reports the threat of a system error or overloading early on so that preventative measures can be taken.

ServerView enables the management of all PRIMERGY servers in the network via a central console. The following key features are supported among others by ServerView in this context.

● Remote power-on (Wake On LAN)

● Temperature monitoring of the CPU and the surrounding area

● Monitoring of the utilization of the PCI buses

● Detailed status and error reports for bus systems, processors and main memory

● Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event of failure of memory modules or processors

● Power monitoring

● Early detection of a defective fan

● Watchdog timer for operating system monitoring and application monitoring with ASR&R

Page 15: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 15

Introduction Features

Further information on ServerView server management is provided in the associated documentation (see “Related Publications” on page 103).

Page 16: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

16 Operating manual RX300 S3

Features Introduction

ServerStart

You can configure the PRIMERGY server quickly and purposefully with the ServerStart software provided. User-guided menus are available for installing the server operating system (for further details see section “Configuring the Server” on page 60).

Service and support

PRIMERGY servers are service-friendly and modular, thus enabling quick and simple maintenance.

The handles and locks (touch points) of the different hot-plug components are colored green to ensure simple and immediate recognition.

In order to avoid damage to components by incorrect handling when they are being installed and removed, green highlighting also identifies the component areas that can be touched without causing damage to the respective component.

PRIMERGY Diagnostic LEDs arranged on the system board identify the component (memory module, CPU) on the system board that is not functioning correctly.

The flash EPROM program supplied with the Fujitsu Siemens Computers utilities supports a fast BIOS update.

The integrated Remote Management Cotnroller (iRMC) as well as the optional remote test and diagnostics system allow the PRIMERGY RX300 S3 server to be maintained from remote locations. Remote diagnosis can be performed as a result for system analysis, remote configuration and remote restart should the operating system or hardware fail.

RemoteView

RemoteView is the remote management solution from Fujitsu Siemens Computers for Intel-based PRIMERGY systems. RemoteView and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operability in the event of errors.

Page 17: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 17

Introduction Features

Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution.

RemoteView helps

● switch ON/OFF the system remotely

● monitor systems and analyze the cause of faults

● prepare error resolution or to have this process initiated independently if possible

● identify potential sources of error

● configure the system

● adjust system settings and initiate system restarts from a remote location

Page 18: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

18 Operating manual RX300 S3

Notational Conventions Introduction

1.3 Notational Conventions

The following notational conventions are used in this manual:

1.4 Technical Data

Electrical data (hot-swap power supply unit)

National and international standards

text in italics indicate commands, menu items or software programs

„Quotation marks“ indicate names of chapters and terms that are being emphasized

Ê describes activities that must be performed in the order shown

V CAUTION! pay particular attention to texts marked with this symbol; failure to observe this warning may endanger your life, destroy the system or lead to the loss of data

I indicates additional information, notes and tips

Power supply unit Multi-range

Rated voltage range 100 V - 240 V

Frequency 50 Hz - 60 Hz

Rated current in basic configuration: 4,2 A - 1,4 A / 100 V - 240 V

Max. rated current 8,5 A - 3,8 A / 100 V -240 V

Effective power 681 W

Apparent power 689 VA

Heat dissipation 2452 kJ/h (2324 btu/h)

Main power fuse 16 A

Protection class I

Product safety IEC 60950-1 / EN 60950-1 / UL 60950-1, CAN/CSA-C22.2 No. 60950-1

Page 19: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 19

Introduction Technical Data

Mechanical values

Weight

approx. 25 kg (depending on the configuration)

Ventilation clearance

at least 200 mm on the front and on the rear side

Ergonomics EK1-ITB 2000

Electromagnetic compatibility FCC class AVCCI class A /JEIDACNS 13438 class AC-Tick class A

Interference emission EN 55022 class A

Harmonic current EN 61000-3-2

Flicker EN 61000-3-3

Interference immunity EN 55024

International standards FCC class AVCCI class A / JEIDAC-Tick class ABSMI class A

CE label according to EU direc-tives

Low-Voltage Directive 73/23/EEC(product safety)Electromagnetic Compatibility 89/336/EEC

Width (without front panel) 445 mm

Total depth (with front panel) 785 mm

Height 85 mm bzw. 2HE

Installation depth 745 mm

cabling depth in the rack 100,0 mm (1000 mm Rack empfohlen)

Page 20: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

20 Operating manual RX300 S3

Technical Data Introduction

Environmental conditions

Condensation during operation must be avoided!

Noise level

Environment class 3K2Environment class 2K2

EN 60721 section 3-3EN 60721 section 3-2

Temperature: Operation (3K2) Transport (2K2)

15°C .... 35°C- 25°C .... 60°C

Humidity 10% .... .85%

Sound power level LWAd (ISO 9296) ≤ 7,1 B (standby) ≤ 7,3 B (operating)

Sound pressure level at bystander position LpAm (ISO 9296)

≤ 57 dB(A) (standby) ≤ 58 dB(A) (operating)

Page 21: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 21

2 Installation Steps: OverviewIn this chapter you will find an overview of the steps necessary to install your server system. Links guide you to sections where you can find more detailed information on the individual steps:

Ê At first, please take notice of chapter “Important Notes” on page 23ff,

Ê The server is accompanied by several loose items. Keep these items in a safe place. They are required for fitting additional add-on components.

Ê Unpack the system, check the contents of the package for visible transport damage and check whether the delivery agrees with the details in the delivery note (see section “Unpacking the Server” on page 34).

Ê Transport the server to the place where you want to set it up.

Ê Make sure all necessary manuals (see section “Overview of the Documen-tation” on page 7) are available; possibly print of the PDF files.

Ê Mounting the server into the rack (see section “Installing/Removing the Server into/from the Rack” on page 34).

Ê Cable the server. Please also refer to the section “Connecting Devices to Server” on page 44 and section “Instructions on Connecting and Discon-necting Cables” on page 47.

Ê Connect the system to the line voltage (see section “Connecting the Server to the Line Voltage” on page 45).

Ê Make yourself familiar with the operating and indicator elements on the front and on the rear side of the server (see section “Operating and Indicator Elements” on page 49).

Ê Configure and install the desired operating system and applications. To do so, you have the following possibilities:

– Remote configuration and installation with ServerStart:

With the ServerStart-DVD provided, you can configure the server and install the operating system in a convenient manner.

To find out how to operate ServerStart and for further information, refer to the corresponding booklet „PRIMERGY ServerView Suite - ServerStart“.

You find additional information for configuration in section “Configuration with ServerStart” on page 60).

Page 22: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

22 Operating manual RX300 S3

Installation Steps: Overview

– Local configuration and installation with and/or without ServerStart (see section “Configuration with ServerStart” on page 60 and/or section “Configuration without ServerStart” on page 61).

I For further information on remote or local installation of the server please refer to the ServerStart manual. The manual contains a “Quick Step Guide“. A PDF version of the manual is contained on the PRIMERGY ServerBooks DVD.

Page 23: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 23

3 Important NotesIn this chapter you will find essential information regarding safety when working with your server.

3.1 Safety

I The following safety notes are also provided in the “Safety ” manual.

This device complies with the relevant safety regulations for data processing equipment.

If you have any questions about where you can set up the device, contact your sales outlet or our customer service team.

V CAUTION!

The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability.

Page 24: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

24 Operating manual RX300 S3

Safety Important Notes

Before operating the device

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device (see section “Technical Data” on page 20).

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

● The server automatically sets itself to a voltage in the ranges of 200 V - 240 V. Make sure that your local voltage is within this range.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug(s) from the grounded insulated socket(s).

Page 25: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 25

Important Notes Safety

V CAUTION!

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.

● Data and signal cables must be adequately shielded.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

● Route the cables in such a way that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Make sure that no objects (such as bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug(s) and contact your sales outlet or customer service team.

● Proper operation of the device (in accordance with IEC 60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● You may only set those resolutions and refresh rates specified in the „Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Page 26: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

26 Operating manual RX300 S3

Safety Important Notes

V CAUTION!

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

● The components marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.

Notes on handlingCDs and CD-/DVD-ROM drives

V CAUTION!

● Use only CDs in proper condition in the CD-/DVD-ROM drive of your server to prevent data loss, damage to the device and injuries.

● Therefore, check each CD for damage, cracks, breakage etc. before inserting it in the drive.

Please note that any additional labels applied may change the mechanical properties of a CD and cause imbalance.

Damaged and imbalanced CDs can break at high drive speeds (data loss).

Under certain conditions sharp-edged pieces of broken CDs can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).

Page 27: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 27

Important Notes Safety

I You protect the CD-/DVD-ROM drive and prevent mechanical damage, as well as premature wearing of the CDs, by observing the following suggestions:

– Only insert the CDs in the drive when needed and remove them after use.

– Store the CDs in suitable sleeves.– Protect the CDs from exposure to heat and direct sunlight.

Note about the laser

The CD-/DVD-ROM drive is classified for laser class 1 according to IEC 60825-1.

V CAUTION!

The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.

Never remove parts of the CD-/DVD-ROM drive assembly!

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board). If possibly inserted auxiliary boards contain batteries/accus the appropiate references in the associated manuals are to be considered.

● Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste.

● The battery must be disposed of in accordance with local regulations concerning special waste.

Page 28: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

28 Operating manual RX300 S3

Safety Important Notes

V ● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board (see “Related Publications” on page 103). If possibly inserted auxiliary boards contain batteries/accus the appropiate references in the associated manuals are to be considered.

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 3: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug(s) from the power socket(s) before inserting or removing components containing ESDs.

● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Only touch the components at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

Page 29: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 29

Important Notes CE Certificate

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Other important points:

● When cleaning the device, please observe the relevant notes in section “Cleaning the Server” on page 63.

● Keep this operating manual and all additional documentation (such asthe technical manual, CD) together with the device. All documentation should be included if the device is passed on to a third party.

3.2 CE Certificate

The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC „Electromagnetic compatibility“ and 73/23/EEC „Low voltage directive“. The device therefore qualifies for the CE certificate (CE=Communauté Européenne).

Page 30: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

30 Operating manual RX300 S3

Transporting the Server Important Notes

3.3 Transporting the Server

V CAUTION!

Only transport the server to the new site in its original packaging or in packaging that protects it from knocks and jolts. Do not unpack the server until it is at its installation location.

If you need to lift or transport the server, ask other people to help you.

3.4 Notes on Installing into the Rack

V CAUTION!

● For safety reasons, at least two people are required to install the system in the rack because of its weight and size.

● When connecting and disconnecting cables, observe the relevant notes in the chapter „Important notes“ in the technical manual for the corresponding rack. The technical manual is supplied with the corre-sponding rack.

● Make sure when installing the rack that the anti-tilt mechanism is properly mounted.

● For safety reasons, no more than one unit may be removed from the rack at any one time during installation and maintenance work.

● If several units are removed from the rack at the same time, there is a risk that the rack will tilt forward.

● The rack must be connected to the power supply by an authorized specialist (electrician).

● If the server is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for non-industrial (public) power supply networks for the type A connector.

Page 31: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 31

Important Notes Environment Protection

3.5 Environment Protection

Environmentally-friendly product design and development

This product has been designed in accordance with the Fujitsu Siemens Computers standard for “environmentally friendly product design and devel-opment”. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of disassembly and recycling have been taken into account.

This saves resources and thus reduces the harm done to the environment.

Notes on saving energy

Devices that do not have to be switched on permanently should be switched off until they are needed as well as during long breaks and after completion of work.

Notes on packaging

Please do not throw away the packaging. You may need it later for transporting your system unit. If possible, the device should only be transported in its original packaging.

Information on handling consumables

Please dispose of printer consumables and batteries in accordance with the applicable national regulations.

In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufac-turer, dealer or an authorized agent for recycling or disposal.

All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants:

Cd Cadmium Hg Mercury Pb Lead

Labels on plastic casing parts

Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them.

Page 32: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

32 Operating manual RX300 S3

Environment Protection Important Notes

Returns, recycling and disposal

Details regarding the return and recycling of devices and consumables within Europe can also be found in the “Returning used devices” manual, via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn:

Fujitsu Siemens ComputersRecycling CenterD-33106 Paderborn

Tel. +49 5251 8 18010

Fax +49 5251 8 18015

The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EG on waste electrical and electronic equipment (WEEE).This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at www.fujitsu-siemens.com/recycling.

Page 33: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 33

4 Hardware InstallationV CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 23.

Do not expose the server to extreme environmental conditions (see section “Technical Data” on page 18). Protect it from dust, humidity, and heat.

Never expose a HDD module to a temperature shock (see section “Handling Hard Disk Drives/HDD Modules” on page 77).

Avoid the formation of condensation inside and on the outside of the hard disk drives before setting up the server must be acclimatized in its operating environment for an acclimatization time (table 3).

I The temperature difference in table 3 represents the difference between the operating temperature and the external, transport or storage temperature.

Temperature difference (°C)(operating environment/outside temperature)

Minimum acclimatization time

(hours)

5 3

10 5

15 7

20 8

25 9

30 10

Table 3: Acclimatization time

Page 34: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

34 Operating manual RX300 S3

Unpacking the Server Hardware Installation

4.1 Unpacking the Server

V CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 23.

If you need to lift or transport the server, ask other people to help you.

Do not unpack the server until it is at its installation location.

Ê Transport the server to the place where you want to set it up.

It is recommended not to throw away the original packaging material as it may be required for transportation at a later date.

Ê Unpack all individual parts.

Ê Check the delivery for any damage during transport.

Ê Check whether the delivery agrees with the details on the delivery receipt.

The identification rating plate is located on the rear area on the server.

Notify your supplier immediately should you discover that the delivery does not correspond to the delivery receipt.

4.2 Installing/Removing the Server into/from the Rack

V CAUTION!

● Please observe the safety notes in chapter “Important Notes” on page 23 and in the section “Notes on Installing into the Rack” on page 30.

● At least two people are needed to position the server into/out of the rack.

● The rack can tip over when more than one unit is pulled out.

● The server may not occupy the top height unit of the rack (38 HU/42 HU PRIMECENTER Rack and/or DataCenter Rack), as otherwise no board and/or fan can be replaced even with the unit pulled out completely.

Page 35: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 35

Hardware Installation Installing/Removing the Server into/from the Rack

Requirements of the rack

The rack systems of the Fujitsu Siemens Computers (PRIMECENTER Rack and DataCenter Rack) support fully the installation of the PRIMERGY server systems. The installation into the at present usual rack systems of different foreign manufacturers (3rd-Party Rack) is supported to large part.

To accommodate the ventilation concept and ensure proper ventilation of the components in the rack, any unused areas must be closed using dummy covers.

The power is supplied via the socket strips available in the rack.

The main features of the rack systems of the Fujitsu Siemens Computers are:

PRIMECENTER Rack

– Frontally bolted telescopic rails.

The rails are provided with a linear alignment possibility to ensure also an adjustment to different rack depths.

– Extended cable management within the lateral rack area.

DataCenter Rack

– Frontally bolted telescopic rails (except within the rear left area where a support bracket is used).

– Extended cable management within the lateral rack area.

The mounting of the rails in the different racks is described in the next sections.

The mounting of the cable management is described in detail in the Technical Manual to the respective rack.

To rack systems of different foreign manufacturers the following applies:

Page 36: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

36 Operating manual RX300 S3

Installing/Removing the Server into/from the Rack Hardware Installation

3rd-Party Rack

Certain boundary conditions are to be fulfilled:

– Installation dimensions (see the dimensions shown in figure 4 on page 37).

– The operability of the safety mechanisms at the server e.g. stoppers or holding back systems must be guaranteed.

– The form of the rack support uprights must ensure the frontal screwing on of the rails.

– Frontally bolted telescopic rails.

The rails are provided with a linear alignment possibility to ensure also an adjustment to different rack depths.

– No support of the cable management (delivered with the mounting kit).

– Climatic conditions.For the ventilation of the installed server a large extent unhindered air intake in the rack front and air discharge in the rear cover of the rack are necessary.

1 rack front side

2 rack rear side

A rack depth (comparison PRIMECENTER Rack 940/1000 mm)

B rack width (comparison PRIMECENTER Rack 700 mm)

C clearance of the 19-inch installation level

C1 front 19-inch installation level

C2 rear 19-inch installation level

D area for cable routing (cable area depth) and ventilation

E area for front panel and ventilation

F right and left area for support systems

P PRIMERGY installation depth

a1 front left support upright

a2 front right support upright

b1 rear left support upright

b2 rear right support upright

Page 37: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 37

Hardware Installation Installing/Removing the Server into/from the Rack

In principle the ventilation concept plans that the necessary cooling is reached by the horizontal self-ventilation of the installed devices (air flow from the front to the rear).

– Power supply.For the installation in 3rd-Party Racks it is to be made certain that appro-priate socket strips are present.

Figure 4: Mechanical conditions

Page 38: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

38 Operating manual RX300 S3

Installing/Removing the Server into/from the Rack Hardware Installation

4.2.1 Mounting into the PRIMECENTER/DataCenter Rack

For mounting the server into the PRIMECENTER/DataCenter Rack the following parts are necessary:

– support bracket– one left and one right telescopic rail (assembled) – M5-10 screws including plugwashers

I – Alternatively, M5x10 screws with separate plugwashers can be used. In this case, two plugwashers must be pre-mounted at the support uprights and the support bracket.

– In this section instructions and figures include the vario rail.

– General information are provided in the Technical Manual for the PRIMECENTER and/or DataCenter Rack (see also “Related Publica-tions” on page 103).

For mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack, the delivered support bracket must first be mounted on the rear left support upright. The bracket must be mounted level with the lower edge of the device.

Figure 5: Mounting the support bracket

Ê Place the support bracket at the appropriate height on the left rear support upright (insert the positioning nub (n) into the corresponding hole) and secure the bracket as described in the Technical Manual of the corre-sponding Rack.

Page 39: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 39

Hardware Installation Installing/Removing the Server into/from the Rack

Figure 6: Removing the outermost telescopic rail

Ê Open the telescopic rail completely (1).

Ê Unlock the outermost telescopic rail (2) and remove it.

Ê Repeat the steps with the second telescopic rail.

I To fasten the telescopic rails, no flange nuts are necessary since the rails are equipped with threaded holes.

Page 40: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

40 Operating manual RX300 S3

Installing/Removing the Server into/from the Rack Hardware Installation

Mounting the telescopic rails on Vario Rails

Figure 7: Mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack

Ê Position (1) the left rail onto the support bracket (b) by inserting the small horizontal lead (c) in the corresponding hole.

Ê Press the rail together (2), position it onto the front support upright, and release it again. This will clamp the rail between the front left support upright and the support bracket. The rail will be adjust automatically in the rack clearance depth.

Ê Secure the rail on the support upright (a) and on the support bracket (b), each with two screws M5x10 including plugwashers (3).

Ê Repeat the steps with the right rail (to be mounted on the right support uprights).

Ê Mount the PRIMECENTER/DataCenter Rack cable management as described in the Technical Manual of the PRIMECENTER Rack.

Ê Mount the server (see section “Installing the Server” on page 42).

Ê With the server inserted route the cables as described in the technical manual of the corresponding rack.

Page 41: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 41

Hardware Installation Installing/Removing the Server into/from the Rack

4.2.2 Mounting into 3rd-Party Racks

For mounting the server into the 3rd-Party Rack the following parts are necessary:

– one left and one right telescopic rail (assembled) – M5-10 screws including plugwashers

I – Alternatively, M5x10 screws with separate plugwashers can be used. In this case, two plugwashers must be pre-mounted at the support uprights and the support bracket.

– In this section instructions and figures include the vario rail.

Ê Take the manual of the rack manufacturer regarding the mechanical instal-lation and/or the climatic conditions to assistance.

V CAUTION!

With the installation in 3rd-Party Rack it is to be made certain that the air flow is ensured from the front to the rear in the rack.

Ê Mount the necessary manufacturer original parts (like support bracket or cable management).

I Sometimes a number of parts of the delivered mounting kit cannot be used because original parts of the 3rd-Party Rack are to be used.

Ê Remove the outermost telescopic rail as described on page 39 (figure 6).

Rack with clearance depth 735 mm

For rack systems with clearance depth 735 mm an adjustment of the delivered rails is not necessary.

Ê Mount the telescopic rails in the 3rd-Party Rack as described in section “Mounting into the PRIMECENTER/DataCenter Rack” on page 38.

Ê Mount the server (see section “Installing the Server” on page 42) and route the cables as described in the original manual of the Rack.

Page 42: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

42 Operating manual RX300 S3

Installing/Removing the Server into/from the Rack Hardware Installation

Rack with clearance depth differing from 735 mm

For rack systems with clearance depth differing from 735 mm a length adjustment of the delivered rails is to be made before mounting it into the rack. This length adjustment is possible within the scope of the slide element.

Ê Mount the telescopic rails as described in section “Mounting into the PRIME-CENTER/DataCenter Rack” on page 38.

Ê Mount the server (see section “Installing the Server” on page 42) and route the cables as described in the original manual of the Rack.

4.2.3 Installing the Server

Figure 8: Preparing the server

Ê Attach the telescopic rail to the server, one onto each side (see arrow 1 in figure 8). Push the telescopic rails towards the server front until they lock in place (see arrow 2 in figure 8).

Ê Open the telescopic rails completely toward the front. They must click into place so that you can no longer push them back.

1

1

2

Page 43: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 43

Hardware Installation Installing/Removing the Server into/from the Rack

Figure 9: Installing the server

V CAUTION!

At least two people are needed to position the server in the rack.

Ê Insert the prepared server into the projecting internal telescopic rails (1) until the rails click into place.

Ê Release the locking mechanism of both rails (2) and insert the server completely into the rack (3).

Ê Fasten the server (4) using two knurled screws (front panel).

To remove the server, follow the same procedure in the reverse order.

2

3

3

4

4

1

Page 44: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

44 Operating manual RX300 S3

Connecting Devices to Server Hardware Installation

4.3 Connecting Devices to Server

The ports for external devices are on the rear of the server. Which additional ports are available on your server depends on the options and/or the PCI boards installed.

The standard ports (figure 10) are marked with symbols, and some are color-coded.

Figure 10: Ports and connectors

I Some of the devices that can be connected may require special drivers (see the documentation for the connected device).

Ê Connect the data cables to the server and peripherals.

1 Mouse port (PS/2) (green) 5 USB port 1 and 2 (black)

2 LAN port 2 (10/100/1000 MBps) 6 Serial port COM1 (turquoise)

3 LAN port 1(10/100/1000 MBps) 7 Keyboard port (PS/2) (purple)

4 Monitor port (VGA) (blue) 8 Power supply connectors

1

27 6 5 4 3

8

LAN 1 LAN 2

LAN 1 LAN 2+

+

Page 45: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 45

Hardware Installation Connecting the Server to the Line Voltage

You find two additional USB ports (1) on the front of the server (figure 11).

Figure 11: Front side: USB ports 3 and 4

Connecting the keyboard, mouse and monitor

Ê Connect the monitor, the keyboard and mouse to the standard ports of the server (see table and figure 10 on page 44).

I If a separate graphics card is installed in a slot, the graphic controller on the system board is automatically deactivated. The corresponding monitor port can not be used. Plug the data cable of the monitor into the monitor port of the graphics card.

Ê Connect the power cable of the monitor to the mains socket strip of the rack.

V CAUTION!

The rated current for the monitor can be found on the technical data label on the monitor or in the operating manual for the monitor.

4.4 Connecting the Server to the Line Voltage

In its basic configuration level the server has a hot-plug power supply unit. A second hot-plug e power supply unit can be added to achieve redundant power supply. If a defect occurs in one power supply unit, the respective other power supply unit ensures further operation.

!

Page 46: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

46 Operating manual RX300 S3

Connecting the Server to the Line Voltage Hardware Installation

V CAUTION!

The server automatically sets itself to a voltage in the range of 200 V - 240 V. Make sure that your local voltage is within this range.

Figure 12: Connecting the server to the line voltage

Ê Connect the insulated connector of the power cable to the power supply unit of the server (1), and the power plug into the mains socket strip of the rack (see Technical Manual of the rack).

I A phase redundancy in the power supply of the server can be set up if two hot-plug power supply units are installed.

In this case the two power supply units can be directly connected to two different phases.

Page 47: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 47

Hardware Installation Connecting and Disconnecting Cables

4.5 Instructions on Connecting and Disconnecting Cables

V CAUTION!

Be sure to read the documentation for the peripheral devices before connecting them.

Do not connect or disconnect data cables during a thunderstorm.

When removing a cable, always hold it by the plug. Never unplug a cable by pulling at the cable itself.

Connect and disconnect the cables in the order described below.

Connecting cables

Ê Turn off all power and equipment switches.

Ê Pull all power plugs out of the grounded power sockets.

Ê Plug all cables into the server and peripherals.

Ê Plug all data communication cables into the utility sockets.

Ê Plug all power cables into the grounded power sockets.

Disconnecting cables

Ê Turn off all power and equipment switches.

Ê Pull all power plugs out of the grounded power sockets.

Ê Unplug all data communication cables from the utility sockets.

Ê Disconnect the relevant cables from the server and all the peripherals.

Page 48: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error
Page 49: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 49

5 Preparation for Use and Operation

V CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 23.

5.1 Operating and Indicator Elements

5.1.1 The Front

The operating and indicator elements on the front side are show in figure 13 on page 50.

Operating elements

ON/OFF button

When the system is switched OFF, it can be switched ON again by pressing the ON/OFF button. When the system is operating, pressing the ON/OFF button will switch OFF the system.

I The ON/OFF button does not disconnect the server from the mains. To disconnect from the mains completely, remove the power plug(s).

NMI NMI button

I Please do not press! The NMI button may only be used by Service.

RST Reset button

Pressing the reset button reboots the system.

Page 50: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

50 Operating manual RX300 S3

Operating and Indicator Elements Preparation for Use and Operation

Figure 13: The front side

Indicators on the control panel

ID Identification (ID) button

The ID indicators on the front and on the rear of the server lights up (blue) when the ID button is pressed. The two ID indicators are synchronized.

1 HDD BUSY indicator 7 Drive access indicator

2 HDD FAULT indicator 8 Global Error indicator

3 Floppy disk drive indicator 9 ON/OFF button

4 ID indicator 10 NMI button

5 ID button 11 Reset button

6 Power-on indicator 12 CD-ROM-/DVD-ROM indicator

Power-on indicator (bicolor)

Lights orange when the server is switched OFF, but mains voltage is present (standby mode).

Lights green when the server is switched ON.

!

!

Page 51: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 51

Preparation for Use and Operation Operating and Indicator Elements

Indicators on the drives

CD-/DVD-ROM indicator

Lights green when the storage medium is being accessed.

Floppy disk drive indicator

Lights green when the storage medium is being accessed.

Drive access indicator (green)

An internal SAS drive (HDD) is being accessed.

Global Error indicator

Does not light when the system is ok. No service incident or critical event has occurred.

Lights orange when a prefailure event has been recognized. Users can check system- and eventlog or via ServerView for event details.

Flashes orange when a critical event has occurred. Users can check BIOS Setup, system- and eventlog or via ServerView for event details.

If the event is still acute after a power failure, the indicator is activated after the restart.

ID ID indicator (blue)

Lights blue when the system has been selected by pressing the ID button. To deactivate, press the button again.

The ID indicator can also be activated via ServerView and its status reported to ServerView.

!

Page 52: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

52 Operating manual RX300 S3

Operating and Indicator Elements Preparation for Use and Operation

Indicators on the optional USB hot-plug tape drive

Figure 14: USB Hot-plug tape drive

Hard disk drive indicators

Figure 15: 3.5-inch HDD module: indicators

1 Clean indicator

2 Media indicator

3 Drive indicator

Table 4:

1 23

Page 53: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 53

Preparation for Use and Operation Operating and Indicator Elements

Figure 16: 2.5-inch HDD module: indicators

LED green

HDD BUSY

– lights: HDD in active phase– does not light: HDD inactive

LED orange

HDD FAULT (in conjunction with a RAID controller)

– does not light: No HDD Error– lights: HDD Faulty or Rebuild Stopped (drive defective/needs

replacing, a rebuild process was stopped or the HDD module is not correctly inserted)

– slow blink: HDD Rebuild (the data is restored by the RAID controller after changing a hard disk drive)

– fast blink: HDD Identify– four fast blinks/pause: HDD Predicted Fault– two fast blinks/pause: HDD Hot Spare (Hot spare drive active. The

corresponding drive has failed).

Page 54: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

54 Operating manual RX300 S3

Operating and Indicator Elements Preparation for Use and Operation

5.1.2 The Rear Side

Figure 17: Connection panel: indicators

Indicators on the connection panel

1 - 4: Indicators on the connection panel (see page 54)

5, 6: Indicators on the hot-plug PCI slots (see page 56)

7, 8: Indicators on the hot-plug PSU (see page 57)

1 Global Error indicator (orange)

Does not light when the system is ok. No service incident or critical event has occurred.

Lights orange when a prefailure event has been recognized. Users can check system- and eventlog or via ServerView for event details.

Flashes orange when a critical event has occurred. Users can check BIOS Setup, system- and eventlog or via ServerView for event details.

If the event is still acute after a power failure, the indicator is activated after the restart.

LAN 1 LAN 2

LAN 1 LAN 2+

+

Page 55: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 55

Preparation for Use and Operation Operating and Indicator Elements

2 ID indicator (blue)

Lights blue when the system has been selected by pressing the ID button on the front. To deactivate, press the button again.

The ID indicator on the front also lights up at the same time. The two ID indicators are synchronized.

The ID indicator can also be activated via ServerView and its status reported to ServerView.

3 LAN transfer rate indicator (bicolor)

Lights orange for a LAN transfer rate of 1 Gbps.

Lights green for a LAN transfer rate of 100 Mbps.

Does not light for a LAN transfer rate of 10 Mbps (or there is no LAN connection available).

4 LAN active indicator (green)

Lights green when a LAN connection is available.

Does not light when there is no LAN connection available.

Flashes when a LAN transfer occurs.

Page 56: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

56 Operating manual RX300 S3

Operating and Indicator Elements Preparation for Use and Operation

Indicators on hot-plug PCI slots

The indicators on these slots behave differently depending on whether (table 5) or not (table 6 on page 57) the operating system supports hot-plug functionality:

Power indicator

(6)/(green)

Error indicator

(5)/(orange)

Status description

does not light

does not light

1. Device switched off.

2. Device operating but PCI slot not powered up. One board may be installed or removed.

flashing does not light

Device operating.

PCI slot is in enable or disable sequence.

Wait until the green LED has changed its status (does not light after disable or lights after enable sequence).

lights does not light

Device operating.

PCI slot powered up. No board may be installed or removed.

does not light

lights Device operating: a problem has occurred.

There are two possible causes for this status:

– The MRL sensor was pressed without authori-zation. This status cannot be exited (NMI initiated: see section “Hot-Plug PCI Error Indicator Lighting” on page 72).

– There was a power failure during the enable sequence (the PCI slot is reset to disable status).

Table 5: Operating system with hot-plug functionality: hot-plug PCI indicator modes

Page 57: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 57

Preparation for Use and Operation Operating and Indicator Elements

Indicators on hot-plug power supply unit

5.1.3 Indicators on the hot-plug CPU and System Fans

For each CPU/system fan a bicolor status indicator (LED on the system board) is assigned. These status indicators are visible only with open housing. The respective LED is set via commands in the server management.

Power indicator

(6)/(green)

Error indicator

(5)/(orange)

Status description

does not light

does not light

Device switched OFF.

lights does not light

Device operating.

PCI slot powered up.

Table 6: Operating system without hot-plug functionality: hot-plug PCI indicator modes

LED Color State Meaning

7 Operation orange ON Line Voltage OK (standby mode)

green ON Server operating

8 Diagnosis orange ON PSU prefailure

ON/OFF PSU fail

LED Meaning

green lights fan operating

orange lights fan prefailure message

flashes fan is defective

Page 58: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

58 Operating manual RX300 S3

Switching the Server ON and OFF Preparation for Use and Operation

5.2 Switching the Server ON and OFF

V CAUTION!

If after switching ON the server there is nothing but flickering stripes on the screen, switch the server OFF immediately (see section “Flickering Stripes Across the Monitor” on page 69).

The ON/OFF button does not disconnect the server from the mains. To disconnect from the mains completely, remove the power plug(s).

Switching the server ON

The power-on indicator (position 6 on figure 13 on page 50) lights orange (standby mode).

– First system installation:

Ê Press the ON/OFF button (position 9 in figure 13 on page 50).

Ê Insert the ServerStart-DVD and/or an installation disk in the corre-sponding drive.

Ê Follow the instructions on the monitor (see also section “Configuration with ServerStart” on page 60 and/or section “Configuration without ServerStart” on page 61).

– System already installed:

Ê Press the ON/OFF button (position 9 in figure 13 on page 50).

The server is switched ON, performs a system test and boots the operating system.

Switching the server OFF

Power-on indicator (position 6 on figure 13 on page 50) lights green.

Ê Shut down the operating system in an orderly manner.

Ê Press the ON/OFF button (position 9 in figure 13 on page 50) and/or send a corresponding control signal (see “Other ON/OFF options” on page 59).

The server switches OFF and remains in standby mode.

Page 59: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 59

Preparation for Use and Operation Switching the Server ON and OFF

Other ON/OFF options

In addition to the ON/OFF button, the server can be switched ON and OFF in the following ways:

– Specified switch-on time/switch-off time

The server is switched ON or OFF at a time specified in the ServerView program.

– Ring indicator

The server is switched ON via an internal or external modem.

– Wake On LAN (WOL)

The server is switched on by a command via the LAN (Magic Package).

– After power failure

The server automatically reboots following a power failure (depending of the settings in the BIOS).

Page 60: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

60 Operating manual RX300 S3

Configuring the Server Preparation for Use and Operation

5.3 Configuring the Server

This section contains information about configuring the server and installing the operating system.

I Make sure that the energy saving functions are disabled in the BIOS Setup during server operation.

5.3.1 Configuration with ServerStart

Configuring IME (RAID Level 1)

The server is equipped with an onboard SAS controller with Integrated Mirroring Enhanced functionality. Configure IME before you begin with ServerStart.

I To configure Integrated Mirroring Enhanced the controller has its own RAID-Select Utility. For further information see “Integrated Mirroring User’s Guide“ on the ServerBooks DVD (choose Controllers from the menu).

With the ServerStart-DVD provided, you can configure the server and install the operating system in a convenient manner. The menu-guided configuration includes the server configuration with the SCU and the RAID configuration with the GAM (Global Array Manager).

I Descriptions of operating systems not covered in the RAID controller manual are provided in the appropriate readme files on the driver diskettes.

To find out how to operate ServerStart and for further information, refer to the “PRIMERGY ServerView Suite - ServerStart“ user manual (see “Related Publi-cations” on page 103).

If you use ServerStart, you can skip the following section on how to configure the server and install the operating system. Continue with section “Starting up Hot-Plug PCI Slots” on page 62.

Page 61: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 61

Preparation for Use and Operation Configuring the Server

5.3.2 Configuration without ServerStart

Configuring IME (RAID Level 1)

The server is equipped with an onboard SAS controller with Integrated Mirroring Enhanced functionality.

I To configure Integrated Mirroring Enhanced the controller has its own RAID-Select Utility. For further information see “Integrated Mirroring User’s Guide“ on the ServerBooks DVD (choose Controllers from the menu).

Configuring the onboard SAS controller with RAID functionality

You will find a description of the onboard SAS controller configuration in the Technical Manual for the system board (see “Related Publications” on page 103).

The configuration of the RAID functionality will be accomplished with the GAM (Global Array Manager).(see “Related Publications” on page 103)

Configuring the PCI RAID controller

If your server is fitted with a PCI RAID controller, you must configure it as described in the related documentation.

Installing the operating system

Ê Insert the installation media ofthe operating system you want to install in the corresponding drive.

Ê Reboot the server.

Ê Follow the instructions on the monitor and in the manual for the operating system.

If your server is equipped with a RAID controller, please read how to install the desired operating system in the related manual.

Page 62: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

62 Operating manual RX300 S3

Starting up Hot-Plug PCI Slots Preparation for Use and Operation

5.4 Starting up Hot-Plug PCI Slots

V CAUTION!

Please note the safety instructions in chapter “Important Notes” on page 23.

In addition to standard slots, the server also has two hot-plug PCI slots. These hot-plug PCI slots allow boards to be installed and removed during operation assuming the operating system supports this functionality.

Every hot-plug PCI slot is assigned two indicators that signal the current status of the slot. The indicators are visible externally on the rear of the server (see figure 17 on page 54).

The possible indicator modes and their meaning are explained in table 5 on page 56 and table 6 on page 57.

If it is attempted to remove the relevant board despite the illuminated green indicator, the slot is automatically powered off to protect the board and the system from any damage (an NMI is initiated/blue screen, system reboot necessary).

V CAUTION!

Not all currently available operating systems support the hot-plug functionality.

The PCI hot-plug software (PCI Card HotReplace) is located on the ServerStart DVD supplied or is installed with the ServerView agents. You will find additional information on installation and operation in the file “README for the PCI Hot Plug Software V3.0” on the ServerStart DVD.

PCI components may only be installed and removed by personnel with the appropriate technical training.

Page 63: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 63

Preparation for Use and Operation Cleaning the Server

5.5 Cleaning the Server

V CAUTION!

Switch the server off and pull the power plug(s) out of the grounded-contact power socket.

Do not clean any interior parts yourself; leave this job to a service technician.

Do not use any cleaning agents that contain abrasives or may corrode plastic.

Ensure that no liquid enters the system. Ensure that the ventilation areas of the server and the monitor are clear.

Clean the keyboard and the mouse with a disinfecting cloth.

Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out.

Page 64: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error
Page 65: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 65

6 Property and Data ProtectionThe server is protected against unauthorized access by means of the lockable rack door.

To protect your system and data internally against unauthorized access, you can use the BIOS Setup security functions.

6.1 BIOS Setup Security Functions

The Security menu in BIOS Setup offers you various options for protecting your data from unauthorized access. By combining these options you can achieve optimum protection for your system.

I You will find a detailed description of the Security menu and how to assign passwords in the manual for the BIOS Setup and on the ServerBooks DVD (see also “Related Publications” on page 103).

Preventing unauthorized BIOS Setup calls

You can activate this protection by entering a setup password in the Security menu. In addition, you can suppress the Press F2 for Setup message in the Security menu. This message is then no longer displayed while the server's startup routine is in progress.

Preventing unauthorized system access

You can activate this protection by entering a system password in the Security menu.

Preventing unauthorized access to the boards with their own BIOS

You can activate this protection by selecting the value Extended for the Setup Password Lock field in the Security menu.

Preventing the system from booting from the floppy disk drive

You can activate this protection by selecting the value Diskette Lock for the System Load field in the Security menu.

Page 66: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

66 Operating manual RX300 S3

BIOS Setup Security Functions Property and Data Protection

Preventing unauthorized writings of floppy disks

To activate this protection, select the value Disabled for the Diskette Write field in the Security menu.

Protecting BIOS from being overwritten

To activate this protection, select the value Disabled for the Flash Write field in the Security menu.

Protecting the server from being switched on by an external device

To activate this protection select the value Disabled for the Remote Power On field in the Security menu.

Protecting the server from being switched off by a program

To activate this protection select the value Disabled for the Soft Power Off field in the Security menu.

Page 67: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 67

7 Troubleshooting and TipsV CAUTION!

Observe the safety information in the „Security“ manual and in chapter “Important Notes” on page 23.

If a problem occurs, try to resolve it as described:

– in this chapter,– in the documentation for the attached devices,– in the help systems of the software used.

If you fail to correct the problem, proceed as follows:

Ê Make a list of the steps and the circumstances that led to the fault. Also make a list of any error messages that were displayed.

Ê Switch OFF the server.

Ê Contact our customer service team.

7.1 Power-On Indicator Remains Dark

The power-on indicator remains dark after switching ON.

Power cord incorrectly connected

Ê Make sure that the power cable is correctly connected to the server and to the grounded socket.

Power supply overloaded

Ê Pull the server power plug(s) out of the power socket(s).

Ê Wait a few seconds before you plug it into the grounded socket(s) again.

Ê Switch ON your server.

Page 68: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

68 Operating manual RX300 S3

The Server switches itself OFF Troubleshooting and Tips

7.2 The Server switches itself OFF

Server management has detected an error

Ê Check the error list or the ErrorLog file in the ServerView program, and attempt to eliminate the error.

7.3 The Monitor Remains Dark

Monitor is switched OFF

Ê Switch ON your monitor.

Screen has gone blank

Ê Press any key on the keyboard.

or

Ê Deactivate screen blanking (screen saver). Enter the appropriate password.

Brightness control is set to dark

Ê Set the brightness control on the monitor to light. For detailed information, please refer to the Operating Manual supplied with your monitor.

Power cable or monitor cable not connected

Ê Switch OFF the monitor and the server.

Ê Check whether the power cable is properly connected to the monitor and to the grounded socket.

Ê Check whether the monitor cable is properly connected to the server and monitor (if it is plugged in with a connector). If a separate graphics card is installed in the server, then the monitor cable must be connected to the graphics card.

Ê Switch ON the monitor and the server.

Page 69: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 69

Troubleshooting and Tips Flickering Stripes Across the Monitor

7.4 Flickering Stripes Across the Monitor

V CAUTION!

Switch OFF the server immediately. Risk of damaging the server.

Monitor does not support the set horizontal frequency

Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or corresponding software for the screen controller for how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

7.5 No Monitor Display or the Display Drifts

The wrong horizontal frequency or resolution has been selected for the monitor or for the application program.

Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or corresponding software for the screen controller for how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

7.6 No Mouse Pointer Displayed on the Monitor

Mouse driver not loaded

Ê Check whether the mouse driver is properly installed and is present when the application program is started. Detailed information can be found in the user manuals for the mouse, the operating system or the application program.

Page 70: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

70 Operating manual RX300 S3

The Floppy Disk Cannot be Read or Written Troubleshooting and Tips

Mouse controller disabled

The mouse controller on the system board must be enabled if you use the supplied mouse.

Ê Check in the BIOS Setup that the mouse controller is Enabled.

7.7 The Floppy Disk Cannot be Read or Written

Ê Check whether the write protection for the floppy disk is activated.

Ê Check the entry for the floppy disk drive in the BIOS Setup.

Ê Check in the BIOS Setup whether the floppy disk drive controller and write permission are enabled (see technical manual for system board on the PRIMERGY ServerBooks DVD).

7.8 Incorrect Time and/or Date

Ê Set the time and/or date in the operating system or in BIOS Setup.

I If the time and date are repeatedly wrong when you switch ON your server, you must change the lithium battery. Contact our Service group.

7.9 System Fails to Boot

The system will not boot after installing a new hard disk drive.

Incorrect SAS configuration

Ê In the SAS configuration menu check the settings for the hard disk drives (SAS Device Configuration) and the additional settings.

Page 71: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 71

Troubleshooting and Tips Drives Are Reported as „Dead“

7.10 Drives Are Reported as „Dead“

This error message may occur when the onboard SAS controller supports RAID functionality or the server has a PCI RAID controller:

RAID controller configuration incorrect

Ê Check and correct the settings for the drives with the RAID controller utility.

Further information is provided in the manual on the RAID controller.

7.11 Added Drive Reported Defective

RAID controller is not configured for this hard disk drive

The drive was probably installed when the system was switched OFF.

Ê Reconfigure the RAID controller for the drive with the corresponding utility. Information is contained in the documentation on the RAID controller.

or

Ê Reinstall the drive while the system is switched ON.

If the hard disk drive continues to be shown as defective, then replace it (see section “Installing/Removing HDD Module” on page 80 and section “Hot-swap for HDD Modules” on page 87).

Page 72: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

72 Operating manual RX300 S3

Hot-Plug PCI Error Indicator Lighting Troubleshooting and Tips

7.12 Hot-Plug PCI Error Indicator Lighting

MRL sensor was pressed without authorization

The locking slide for the relevant hot-plug PCI board bay was activated without authorization.

V CAUTION!

The locking slide may only be activated if both indicators for the relevant PCI slot are not lighting.

If there is a board in the PCI slot whose MRL sensor was illegally pressed, an NMI is initiated (Blue Screen).

Ê Press the ON/OFF button for longer than five seconds or remove the power plug(s).

Ê Reboot the server.

7.13 Hot-Plug PCI Power Indicator not Lighting after Replacing the Board

Incorrect PCI board installed

Only PCI boards of the same type and with the same settings may be exchanged.

If the boards do not match, the new board is not commissioned: the enable sequence is aborted after five seconds and the flashing power indicator extin-guishes.

Ê Check the new PCI board for type and settings (mode, speed).

Ê Repeat the replacement process.

V CAUTION!

Observe the safety information in the in chapter “Important Notes” on page 23.

Page 73: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 73

Troubleshooting and Tips Error Messages on the Monitor

Power failure during enable sequence

The enable sequence was aborted. The PCI board was either not installed correctly (tilted) or the PCI board is defective.

Ê Remove and insert the PCI board correctly.

Ê Repeat the enable process (see section “Replacing hot-plug PCI Boards” on page 90).

If the error occurs again, it is probable that the PCI board is defective.

Ê Repeat the enable process with a new PCI board.

If the error continue to occur, contact our Service group.

7.14 Error Messages on the Monitor

The meanings of the error messages are explained in the manual for the BIOS Setup and in the documentation for the relevant components and programs on the PRIMERGY ServerBooks DVD.

Page 74: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error
Page 75: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 75

8 Hot-plug ComponentsThis chapter describes how to handle hot plug components and/or how to modify your server hardware.

The hot swap procedure (online replacement) increases the availability of the system operation and guarantees a high degree of data integrity and fail-safe performance.

I Upgrades or replacements of permanently installed components are described in the Options Guide and/or in the Service Supplement and may only be performed by Service staff.

V CAUTION!

Please observe the safety information in chapter “Important Notes” on page 23.

8.1 Hot-plug Power Supply Units

I A redundant power supply can be created by installing a second hot-plug power supply unit (optional). If one power supply unit fails, the other unit ensures operation can continue. The defective power supply unit can be replaced online (hot-swap).

8.1.1 Removing the Dummy Module

The slot for the second power supply unit is provided with a dummy module that must be removed before installing a second power supply unit.

Ê Release the fastening screw and remove the dummy module from the slot.

V CAUTION!

Keep the dummy module for future use. If the power supply unit is removed again and not replaced with a new unit, the dummy module must be reinstalled due to cooling, to comply with applicable EMC regulations (regulations on electromagnetic compatibility) and to protect against fire.

Page 76: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

76 Operating manual RX300 S3

Hot-plug Power Supply Units Hot-plug Components

8.1.2 Adding a hot-plug Power Supply Unit

Ê Insert the second power supply unit, lock it in the free location (see section “Replacing a Hot-plug Power Supply Unit”) and connect it to the line voltage (see section “Connecting the Server to the Line Voltage” on page 45).

8.1.3 Replacing a Hot-plug Power Supply Unit

Figure 18: Unlocking and removing the power supply unit

V CAUTION!

Before replacing a non defective power supply unit in a non-redundant configuration (only one power supply unit present) the server must be switched OFF.

Ê Remove the cable from the installed power supply unit.

Ê Push the transport look (green latch) in the direction of the arrow (1) and pull the power supply unit out of the location (2).

Ê Insert the new power supply unit in the empty location until it engages.

I Make sure that the power supply unit engages correctly in the mounting location and is locked in position.

This is the only way to avoid the power supply unit being shaken out of its mountings and damaged during transport.

Ê Connect up the power supply unit.

Page 77: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 77

Hot-plug Components Hot-plug Hard Disk Drives

8.2 Hot-plug Hard Disk Drives

Up to six 3,5-Zoll SAS/SATA hard disk drives or twelf 2,5-Zoll SAS hard disk drivescan be installed in the PRIMERGY RX300 S3 server.

The hard disk drives are mounted on a carrier that allows defective drives to be replaced or new drives to be added online (hot-swap). The hard disk drive and the carrier constitute the hard disk drive module (HDD module).

The hot-swap function (online replacement) can only be performed if the RAID is configured appropriately. Further information about the RAID configuration or RAID level can be found in the RAID controller documentation.

When replacing a HDD module, refer to the hard disk drive indicators in the table on page 53 as well as section “Hot-swap for HDD Modules” on page 87.

8.2.1 Handling Hard Disk Drives/HDD Modules

Hard disk drives incorporated in the HDD modules are highly sensitive electro-magnetic devices and must be handled with great care. It is as likely as not that incorrect handling will lead to partial and/or total failure of the hard disk drives. These failures will result in data errors and to loss of data or to total corruption of the hard disk drive.

Please observe the following rules, which will help avoid such problems occurring:

● Store and transport HDD modules only within the limits stipulated in the specification.

● When transporting HDD modules (even over short distances), always use the original packaging (ESD labeling).

● Never expose a HDD module to a temperature shock. Avoid the formation of condensation inside and on the outside of the hard disk drive. The hard disk drives may only be exposed to defined temperature and climatic conditions.

● Always put the HDD module down carefully, with its largest surface facing downwards, to avoid the danger of tipping over.

Page 78: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

78 Operating manual RX300 S3

Hot-plug Hard Disk Drives Hot-plug Components

8.2.2 Removing/installing the dummy module

Free slots are provided with a dummy module that must be removed before installing an additional HDD module.

Removing/installing the 3.5-inch dummy module

Figure 19: Removing the 3.5-inch dummy module

Ê Press both tabs on the dummy module together (see figure 19) until the locking mechanism disengages and remove the dummy module from the mounting location.

The dummy module is installed in the reverse order.

V CAUTION!

Keep the dummy module for future use. If the HDD module is removed again and not replaced with a new module, the dummy module must be reinstalled due to cooling, to comply with applicable EMC regulations (regulations on electromagnetic compatibility) and to protect against fire.

Page 79: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 79

Hot-plug Components Hot-plug Hard Disk Drives

Removing/installing the 2.5-inch dummy module

Figure 20: Removing the 2.5-inch dummy module

Ê Press both tabs on the dummy module together until the locking mechanism disengages (1) and remove the dummy module from the mounting location (2).

The dummy module is installed in the reverse order.

V CAUTION!

Keep the dummy module for future use. If the HDD module is removed again and not replaced with a new module, the dummy module must be reinstalled due to cooling, to comply with applicable EMC regulations (regulations on electromagnetic compatibility) and to protect against fire.

Page 80: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

80 Operating manual RX300 S3

Hot-plug Hard Disk Drives Hot-plug Components

8.2.3 Installing/Removing HDD Module

V CAUTION!

Under no circumstances should you remove a HDD module while the system is in operation if you are not sure that the hard disk drive is operated by a RAID controller and belongs to a disk array that is operating in RAID level 1,5 or 10.

V CAUTION!

The HDD module must be acclimatized in its operating environment for an acclimatization time (table 7).

V CAUTION!

The HDD modules (drives) must be marked clearly so that they can be put back into their original place after an upgrade. If this is not taken into account, existing data can be destroyed.

I So that the storage capacity of the hard disk can be recognized at a glance when the hard disk drive is replaced, several prefabricated stickers with the storage capacities are provided with the server. Each HDD module should bear a sticker indicating its capacity on the front (position 5 in figure 21 on page 81). Should no suitable sticker be available, blank stickers for labeling are also provided. The stickers are available in several colors to facilitate identification.

Temperature difference (°C)(operating environment/outside temperature)

Minimum acclimatization time

(hours)

5 3

10 5

15 7

20 8

25 9

30 10

Table 7: Acclimatization time for the HDD module

Page 81: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 81

Hot-plug Components Hot-plug Hard Disk Drives

The hard disk drives that can be ordered for the PRIMERGY RX300 S3 are delivered as HDD modules, with the hard disk drives preinstalled on carriers. The hard disk drive may only be removed from the carrier by personnel with the appropriate technical training in compliance with the appropriate ESD guide-lines (see section “Modules with electrostatic-sensitive components” on page 28).

Figure 21: 3.5-inch HDD module and dummy cover

Page 82: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

82 Operating manual RX300 S3

Hot-plug Hard Disk Drives Hot-plug Components

Figure 22: 2.5-inch HDD module and dummy cover

1 HDD module (hard disk drive carrier with installed hard disk drive)

2 IndicatorsHDD busy (LED greenHDD fault (LED orange)Description see table on page 52 in section „Hard disk drive indicators“.

3 Handle for locking and unlocking of the hard disk drive module

4 Locking button

5 Ridge for the application of a sticker with the current drive identifier

6 Dummy module

7 Locking tabs

Page 83: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 83

Hot-plug Components Hot-plug Hard Disk Drives

Unlocking the 3.5-inch HDD module

Figure 23: Unlocking the 3.5-inch HDD module

Ê Open the locking mechanism by pressing the locking button (1).

Ê Push the handle of the HDD module fully in the direction of the arrow.

I If the HDD modules are provided with a transport lock (1 in the next figure) remove these before you open the locking mechanism.

Figure 24: 3.5-inch HDD module: removing the transport lock

Page 84: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

84 Operating manual RX300 S3

Hot-plug Hard Disk Drives Hot-plug Components

Unlocking the 2.5-inch HDD module

Figure 25: Unlocking the 2.5-inch HDD module

Ê Open the locking mechanism by pressing the locking button (1).

Ê Push the handle of the HDD module fully in the direction of the arrow (2).

Page 85: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 85

Hot-plug Components Hot-plug Hard Disk Drives

Installing the 3.5-inch HDD module

Figure 26: Installing the 3.5-inch HDD module

Ê Unlock the HDD module as described in “Unlocking the 3.5-inch HDD module” on page 83.

Ê Carefully push the HDD module into the empty slot (1) until it stops.

Ê Push the handle completely in the direction of the arrow (2) until the locking mechanism (3) engages (4).

2

3

4

1

Page 86: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

86 Operating manual RX300 S3

Hot-plug Hard Disk Drives Hot-plug Components

Installing the 2.5-inch HDD module

I In case of 2.5-inch HDD configurations, no further 3.5-inch HDD modules can be installed.

Figure 27: Installing the 2.5-inch HDD module

Ê Unlock the HDD module as described in “Unlocking the 2.5-inch HDD module” on page 84.

Ê Carefully push the HDD module into the empty slot (1) until it stops.

Ê Push the handle completely in the direction of the arrow (2) until the locking mechanism (3) engages (4).

Page 87: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 87

Hot-plug Components Hot-plug Hard Disk Drives

8.2.4 Hot-swap for HDD Modules

V CAUTION!

The hot-swap function (online replacement) can only be performed if the RAID is configured appropriately.

Only remove a HDD module during operation if the drive is not being accessed. Observe the control LEDs for the corresponding HDD module (see the hard disk drive indicators in the table on page 53).

If you want to replace a HDD module during operation, proceed as follows:

Ê If you want to remove a HDD module that is not defective, set the drive first to offline via the software (RAID controller configuration software).

Ê Now pull out the HDD module a few centimeters.

Ê Wait for at least 60 seconds.

I This period is necessary for the RAID controller to recognize that a HDD module has been pulled out and for the hard disk drive to come to a stop.

Ê Pull out the HDD module fully.

Ê Insert the new HDD module.

If you remove a HDD module and do not replace it with a new module, insert a dummy module into the empty mounting location. Ensure that the dummy module engages correctly in the mounting location.

Page 88: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

88 Operating manual RX300 S3

Hot-plug Fans Hot-plug Components

8.3 Replacing a Hot-plug Fan

V CAUTION!

The actions described in this section may only be performed by personnel with the appropriate technical training. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment.

Please observe the safety information in chapter “Important Notes” on page 23.

In order to replace a defective fan, the housing cover must be removed as the fans are not directly accessible (see section “Opening/Closing the Housing” on page 95).

V CAUTION!

The housing cover must be replaced as fast as possible due to cooling, to comply with applicable EMC regulations (regulations on electromag-netic compatibility) and to protect against fire. The maximum opening time of the housing cover amounts to 15 minutes.

The server is at least equipped with one fan unit which includes four hot-plug fans. The server can be upgraded with a second fan unit with four hot-plug fans.

The prefailure of a fan is notified by the Global Error indicator on the front and rear of the server (lights orange). The defective fan can be identified (figure 28 on page 89) by the appropriate LED (only visible if the server housing is opened) and replaced online (hot-swap).

If only a fan unit is installed, a defective fan must be replaced immediately. If two fan units are installed, the fans are operating in a redundant configuration, in effect a defective fan can be replaced during the next service.

Page 89: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 89

Hot-plug Components Hot-plug Fans

8.3.1 Replacing the Fan

Ê Remove the housing cover (see section “Opening/Closing the Housing” on page 95).

Figure 28: Arrangement of the fans

Ê Identify which fan is defective by the LED 19-24 (lights/flashes orange).

Figure 29: Removing fan

Ê Pull the green handle in the direction of the arrow (1) and disengage the locking mechanism.

Ê Remove the fan from the cartridge (2).

Fan 4 CPUFan 5 CPUFan 6 CPUFan 2 sys

Fan 1 sys Fan 1 CPUFan 2 CPUFan 3 CPU

L23L24

L21L22

L27L28

L25L26

Front

Page 90: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

90 Operating manual RX300 S3

Hot-plug PCI Boards Hot-plug Components

Ê Place the removed fan away from the server.

V CAUTION!

Never place the removed/defective fan within the server, thus preventing a short circuit.

Ê Pull the green handle of the new fan, insert the fan into the fan cartridge and push the handle into position to engage the locking mechanism.

I The fans in the new fan unit are measured via express commands in the server management. As a function of the results the LED (see figure 28 on page 89) is set to light up green (fan o.k.) or to light up orange (fan defective).

Ê Replace the housing cover (see section “Opening/Closing the Housing” on page 95).

8.4 Replacing hot-plug PCI Boards

V CAUTION!

The actions described in this section may only be performed by personnel with the appropriate technical training. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment.

Please observe the safety information in chapter “Important Notes” on page 23.

In order to replace a hot-plug PCI board, the housing cover must be removed as the slots are not directly accessible (see section “Opening/Closing the Housing” on page 95).

V CAUTION!

The housing cover must be replaced as fast as possible due to cooling, to comply with applicable EMC regulations (regulations on electromag-netic compatibility) and to protect against fire. the maximum opening time of the housing cover amounts to 15 minutes.

The failure of a hot-plug PCI board is notified on the corresponding slot on the rear of the server (see table 5 on page 56).

Page 91: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 91

Hot-plug Components Hot-plug PCI Boards

Ê You should read the accompanying documentation supplied with the board beforehand.

I Only PCI boards of the same type and with the same settings may be exchanged. If the boards do not match, the new board will not be commissioned.

Ê Remove the housing cover (see section “Opening/Closing the Housing” on page 95).

Ê If necessary, start the PCI hot-plug software (PCI Card HotReplace). You will find operating instructions in the file “README for the PCI Hot Plug Software V3.0” on the ServerStart DVD.

Ê Deactivate the board using the relevant PCI hot-plug software or by pressing the button (a) (see figure 30 on page 92).

The power indicator for the hot-plug PCI slot (see table 5 on page 56) flashes green. The slot is in the disable sequence.

Ê Wait until the power indicator changes its status (not lighting). The slot is now powered off.

Page 92: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

92 Operating manual RX300 S3

Hot-plug PCI Boards Hot-plug Components

Figure 30: Installing hot-plug PCI board

Ê Move the locking slide on the card guide in the direction of the rear side (1).

V CAUTION!

The locking slide may only be moved if both indicators for the relevant PCI slot are not lighting.

The locking slide activates the MRL sensor, which informs the operating system that the PCI slot has been deactivated.

If the MRL sensor is activated without authorization (one of the LEDs is still lighting) and there is a board in the PCI slot, an NMI is initiated (blue screen). This state cannot be exited. There is a risk that data may be lost.

Ê Remove all cables attached to the board.

Ê Using the pull out aid, remove carefully the board out of the PCI slot (2).

a

1

2

Page 93: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 93

Hot-plug Components Hot-plug PCI Boards

Ê Lift the green movable snap-fits not more than 1 mm, and take the PCI board off.

Ê Mount the new PCI board into the pull out aid as described in the next section.

Ê Insert the pre-assembled PCI board into the hot-plug PCI slot.

Ê Secure the assembly with the locking slide on the card guide (move it in the direction of the server front side).

Ê Activate the board using the relevant software or by pressing the button (a).

The power indicator for the hot-plug PCI slot (see table 5 on page 56) flashes green. The slot is in the enable sequence.

Ê Wait until the power indicator lights constant. The slot is now powered on.

I If the boards do not match, the new board will not be commissioned (see section “Hot-Plug PCI Power Indicator not Lighting after Replacing the Board” on page 72).

Ê Replace the housing cover (see section “Opening/Closing the Housing” on page 95).

Page 94: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

94 Operating manual RX300 S3

Hot-plug PCI Boards Hot-plug Components

8.4.1 Mounting the PCI board into the pull out aid

Before installing the PCI board, it must be mounted into the pull out aid:

Figure 31: Mounting the PCI board into the pull out aid

Ê Press the two green snap-fits down completely (1) and remove it from the guidances (2).

Ê Place the PCI board into the slot of the pull out aid (3).

Ê Carefully press down the green snap-fits (4) until the PCI board is fixed.

Do not jam the board.

2

1

3

2

1

4

4

Page 95: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 95

Hot-plug Components Opening/Closing the Housing

8.5 Opening/Closing the Housing

V CAUTION!

The actions described in this section may only be performed by personnel with the appropriate technical training. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment.

Please observe the safety information in chapter “Important Notes” on page 23.

V CAUTION!

The housing cover must be replaced as fast as possible due to cooling, to comply with applicable EMC regulations (regulations on electromag-netic compatibility) and to protect against fire. The maximum opening time of the housing cover amounts to 15 minutes.

Figure 32: Opening the housing

Ê Push the two locking buttons (1) and remove the cover (2).

Ê For closing place the cover on the housing and slide it in the direction of the server front side until the locking mechanism engages.

2

1

12

Page 96: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error
Page 97: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 97

AbbreviationsAC

Alternating Current

ANSIAmerican National Standard Institut

ASR&RAutomatic Server Reconfiguration and Restart

ATAAdvanced Technology Attachments

BIOSBasic Input-Output System

BMCBaseboard Management Controller

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

Page 98: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

98 Operating manual RX300 S3

Abbreviations

DCDirect Current

DIMMDual Inline Memory Module

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCError Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EMCElectroMagnetic Compatibility)

EMPEmergency Management Port

EPPEnhanced Parallel Port

ESDElectroStatic Discharge

FPCFront Panel Controller

Page 99: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 99

Abbreviations

FRUField Replaceable Unit

FSBFront Side Bus

GAMGlobal Array Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntergrated Drive Electronics

IMEIntergrated Mirroring Enhanced

IRQInterrupt Request Line

LANLocal Area Network

Page 100: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

100 Operating manual RX300 S3

Abbreviations

LBALogical Block Address

LCDLiquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

MMFMulti Mode Faser

MRLManually Retention Latch

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analysing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

Page 101: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 101

Abbreviations

RAMRandom Access Memory

ROMRead-Only Memory

RSBRemote Service Board

RTCReal Time Clock

RTDSRemote Test- und Diagnose-System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SASSerial Attached SCSI

SATASerial ATA

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDDCSingle Device Data Correction

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

Page 102: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

102 Operating manual RX300 S3

Abbreviations

SELSystem Event Log

SMISystem Management Interrupt

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

USBUniversal Serial Bus

VGAVideo Graphics Adapter

Page 103: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 103

Related PublicationsPRIMERGY manuals are available as PDF file on the ServerBooks DVD. The ServerBooks DVD is part of the ServerView Suite delivered with each server system.

The actual version of the necessary manuals can be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL:http://manuals.fujitsu-siemens.com (choose: industry standard servers).

[1] Safety notes and other important information

[2] Warranty

[3] Ergonomics

[4] Returning used devices

[5] PRIMECENTER Rack Technical Manual

[6] PRIMECENTER LC Rack Technisches Handbuch

[7] DataCenter Rack Technical Manual

[8] LocalView User Manual

[9] PRIMERGY ServerView Suite ServerStart

[10] ServerView Server ManagementUser Manual

[11] ServerView ExtensionServerView Extension for HP OpenView NNM

[12] ServerView/Plus for Tivoli

Page 104: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

104 Operating manual RX300 S3

Related Publications

[13] RemoteView User Manual

[14] PRIMERGY RX300 S3 Options Guide

[15] System Board D2119 Technical Manual

[16] BIOS-Setup Reference Manual

[17] Integrated Mirroring User’s Guide

[18] Global Array Manager Client Software User’s Guide

[19] Global Array Manager Server Software User’s Guide

Page 105: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 105

Index

3rd-Party Rackinstalling in 41requirements 36

Aaccessible drives

CD-ROM 12DVD-ROM 12floppy disk drive 12tape drive 12

acclimatization time 80ASR&R 14availability 13

BBIOS

security functions 65BIOS update 16blue screen (error)

MRL sensor illegally activated 72

Ccable management 40cables

connecting 47disconnecting 47

CD-ROM driveindicator 50, 51

CE certification 18, 29chipkill 13cleaning

monitor, mouse, server, keyboard 63

closinghousing 95

componentshardware/software 7

configuringserver 16, 60

connecting

cables 47external devices 47

connectorspower supply 44

Consumables 31control panel 49correcting error 67CPU

fans 13

Ddata manipulation 7data protection 65DataCenter Rack

requirements 35delivery note 34devices

connecting to the server 44disconnecting

cables 47Disposal, devices 32drive

"dead" 71defective 71

drive accessindicator 50, 51

dummy moduleHDD module 78, 79power supply unit 75

DVD-ROM driveindicator 50

EECC 13EDC 13electrical data 18electromagnetic compatibility 18, 29EMC 18Environment Protection 31environmental conditions 20error

Page 106: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

106 Operating manual RX300 S3

Index

display drifts 69drive "dead" 71drive defective 71floppy disk cannot be read or

written 70incorrect PCI board installed 72MRL sensor illegally activated 72no mouse pointer 69power failure during enable

sequence 72screen remains dark 68screen shows flickering

stripes 69server switches off 68system does not boot 70wrong date 70wrong time 70

Error Correcting Code 13Error Detection Code 13error message

on screen 73ESD (devices sensitive to electrostatic

discharge) 28ESD-sensitive devices 28external devices

connecting 47

Ffan

replace 88fans

CPU 13system 13

faultdisplay drifts 69screen dark 69screen shows flickering

stripes 69system does not boot 70

features 9flash EPROM 16floppy disk

cannot be read or written 70floppy disk drive

indicator 50, 51

GGAM 60Global Array Manager (GAM) 60Global Error

indicator 50, 51, 54graphics card 45

Hhard disk drive 11

carrier 77handling 77HDD module 77hot-plug 77indicator 51, 52online replacing 87

HDD BUSYindicator 50

HDD FAULTindicator 50

HDD moduleacclimatization time 80carrier 80dummy module 77handling 77hard disk drive 80hot-plug 14installing/removing 80

height units 38hot-plug

fan 88HDD module 77PCI board 90PCI slot 7power supply unit 13, 45, 75tape drive 12

hot-plug PCIerror indicator 56, 62, 72power indicator 56, 62, 72

hot-plug PCI boardreplacing 90

hot-plug PCI power indicator

Page 107: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 107

Index

does not light when board replaced (error) 72

hot-plug PCI slot 9startup 62

hot-spare memorymemory module 13

hot-swaponline replacement 87

housingclosing 95opening 95

IID

indicator 50, 51, 54ID button 50IME (Integrated Mirroring

Enhanced) 60, 61indicators

CD-ROM 50drive access 50, 51DVD 50floppy disk drive 50Global Error 50, 51, 54hard disk drive 52HDD BUSY 50HDD FAULT 50hot-plug PCI 56, 62, 72ID 50, 51, 54LAN active 55LAN connection 55on the server 49power supply unit 57power-ON indicator 50power-on indicator 67tape drive 52

informationadditional 9

installingPCI hot-plug software 62server 42

installing in3rd-Party Rack 41PRIMECENTER Rack 38

Integrated Mirroring Enhanced (IME) 60, 61

LLabels 31LAN active

indicator 55LAN connection

indicator 55light-emitting diode (LED) 27lithium battery 27LocalView module 12low-voltage directive 18, 29

Mmains voltage

connecting the server 45meaning

of the symbols 18memory module

hot-spare memory 13memory scrubbing 13model rating plate 34monitor

display drifts 69mouse

no mouse pointer on the screen 69

MRL sensorillegally activated (error) 72

NNMI button 49, 50noise level 20notational conventions 18note about the laser 27

OON/OFF button 49, 50onboard SAS controller

configuring 61online replacement

hot-swap 87opening

Page 108: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

108 Operating manual RX300 S3

Index

housing 95operating system

installing 61operation 49operation elements 49overloading 14

Ppackaging 31, 34PCI hot-plug software

installing 62PCI slot

hot-plug 7PDA 14ports 44

keyboard port 44LAN port 44monitor port 44mouse 44USB port 44

power supplyconnectors 44redundant 13, 45

power supply unitadding 76dummy unit 76hot-plug 13, 45, 75indicators 57redundant 45replacing 76wide range 13

power-on indicator 50does not light 67

PRIMECENTER Rackinstalling in 38requirements 35

PRIMERGY DiagnosticLED 16

property protection 65

Rrack

requirements 35RAID controller

configuring 61not configured for hard disk

drive 71RAID level 14Recycling devices 32redundancy

fans 13power supply 13

reliability 13RemoteView 16replacing

hot-plug PCI board 90requirements

3rd-Party Rack 36DataCenter Rack 35PRIMECENTER Rack 35

reset button 49, 50Return of devices 32routing cables 40

Ssafety 23saving energy 31screen

error message 73flickering 69no display 69remains dark 68screen dark 69shows flickering stripes 69

security functions 7setup password 65system password 65unauthorized access 65

serverclosing the housing 95configuring 60connecting external devices 44connecting mains voltage 45control panel 49correcting error 67data protection 65dimensions 19electrical data 18

Page 109: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

RX300 S3 Operating manual 109

Index

environmental conditions 20height units 38hot-plug power supply unit 75ID button 50indicators 49, 50installing 42keyboard port 44LAN port 44monitor port 44mouse port 44NMI button 49, 50noise level 20ON/OFF button 49, 50opening the housing 95operation 49ports 44power-on indicator 50property protection 65reset button 49, 50routing cables 40safety standards 18service 16standards 18startup 49switches itself off (error) 68switching OFF 58switching ON 58technical data 18transport 30troubleshooting 67unpacking 34USB port 44ventilation clearance 19weight 19

server management 14ServerStart 16, 60ServerView 14

supported functions 14service

PRIMERGY Diagnostic LED 16server 16touch point 16

setup password 65standards 18

startuphot-plug PCI slot 62server 49

support bracket 38switching OFF

server 58switching ON

server 58switch-OFF time

define 59switch-ON time

define 59system

fans 13system board 9

PRIMERGY Diagnostic LED 16system does not boot 70system fans

redundant 13system password 65

Ttape drive

hot-plug 12indicator 52

target group 7technical data 18telescopic rail 40, 41, 42time, wrong 70touch point

service 16transport damage 34troubleshooting, server 67

Uunauthorized access 65unpacking

server 34

Vventilation

fans 13ventilation clearance 19

Page 110: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

110 Operating manual RX300 S3

Index

Wweight 19

Page 111: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

Comments on PRIMERGY RX300 S3 Betriebsanleitung

RX300 S3

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MünchenGermany

Fax: 0 700 / 372 00000

e-mail: [email protected]://manuals.fujitsu-siemens.com

Page 112: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error
Page 113: PRIMERGY RX300 S3 - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S3/pdf/ba.pdf · Fax forms for sending us your comments are included in ... 7.12 Hot-Plug PCI Error

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009