Primary Offering 2010 10 - Morocco

Embed Size (px)

Citation preview

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    1/127

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    2/127

    Schneider Electric 2-Energy J. VAGNON 12/10/2010

    AIS Motor starter

    VCB Contactor

    Vacuum interrupters,

    mechanisms,

    actuators

    SF6 CB

    GIS

    Primary Distribution: Offering

    VCB

    Core

    components

    SF6 CBVCB Contactor

    Components

    VCB

    AIS & Motor Starter GIS

    Switchgears(Indoor

    & Outdoor)

    Live tank / Dead TankOutdoor

    Engineered

    Switchgear

    Solutions

    Power Houses / Trackside subs Innovative solutionsPackages

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    3/127

    Circuit Breaker

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    4/127

    Schneider Electric 15-Energy J. VAGNON 12/10/2010

    PIX range

    HVX & FPX VA/H

    Local offering

    GCB

    VX range

    Railway

    Furnace

    BLV

    VISAX EOX

    HVX-O

    China

    HVXO 36 FP

    36/40.5kV

    app.

    Niche segment market andlegacy product

    Core business market

    Actual range of PDS circuit breaker (IEC, GB, GOST & IEEE)Circuit breaker range

    >

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    5/127

    Schneider Electric 16-Energy J. VAGNON 12/10/2010

    Circuit Breaker Range

    HVX range

    VA & VX rangeBLV range

    FP & FPX range

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    6/127

    Schneider Electric 17-Energy J. VAGNON 12/10/2010

    DNF7 China, EOX2500A31,5kA36kVHVX O

    Chinese OEM (KYN28), OEM3150A

    3150A

    50kA

    31.5kA

    12kV

    24 kV

    HVX OOvermolded

    PIX-Compact, PIX-MV, OEM2500A31,5kA17,5kVHVX

    compact

    PIX, PIX High, GCB up to 15kA 50kA

    * Up to 5000A with air forced cooling

    3150A

    5000A*

    50kA17,5kVHVX B

    PIX, PIX double busbar, PMX, OEM2500A40kA

    31,5kA

    17,5kV

    24kV

    HVX A

    PIX, PI, PMX, OEM1250A25kA12kVHVX S

    OpenPole

    Applications & CommentsInIscUn

    HVX range

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    7/127

    Schneider Electric 18-Energy J. VAGNON 12/10/2010

    20

    630

    40

    31,5

    25

    50

    kA

    250016001250 3150

    HVX-SHVX-A

    HVX-B

    HVX-0

    HVXCompact

    Existing and on going HVX range for 12kVHVX range

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    8/127

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    9/127

    Schneider Electric 20-Energy J. VAGNON 12/10/2010

    20

    630

    40

    31,5

    25

    50

    kA

    250016001250 3150

    HVX-A

    Existing and on going HVX range for 24kVHVX range

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    10/127

    Schneider Electric 21-Energy J. VAGNON 12/10/2010

    Fixed type Draw-out typemanual/motor operation

    HVX - F HVX - E

    HVX

    Type and variants with circuit-breaker

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    11/127

    Schneider Electric 22-Energy J. VAGNON 12/10/2010

    Disconnecting TruckUTX-E up to 12 kV

    Disconnecting TruckUTX-E up to 24 kV

    Metering TruckMTX-E with primary fuse

    MTX and UTX - Variant modules

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    12/127

    Schneider Electric 23-Energy J. VAGNON 12/10/2010

    HVX range

    HVX is the consequent development of a new

    generation of circuit breakers as part of a long termproduct platform.

    Core product, designed for the worldwide use up to 24

    kV.

    Very compact design for use in metal-clad switchgearthrough metal enclosed design.

    The HVX block structure creates a economicalsolution for each application.

    HVX up to 24kV

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    13/127

    Schneider Electric 24-Energy J. VAGNON 12/10/2010

    HVX S HVX A(for PIX)

    HVX B(for PIX)

    HVX B(for PIX High)

    HVX Compact(for PIX Compact)

    HVX up to 24kV

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    14/127

    Schneider Electric 25-Energy J. VAGNON 12/10/2010

    IEC 60056, VDE 0670 part 101-108, BS5311, NF-C64

    12 kV 17,5 kV 24 kV

    Rated current A 630-2500 630-2500 630-2500

    Rated short-circuit

    making current kA 40-100 40-100 40-80

    PCS (pole centre spacing) (mm) 165(-F) 185/ 210/185/ 210 210 275(-F)

    Rated short-time

    current kA 16-40 16-40 16-31,5

    3 s 3 s 3s

    HVX RatingsHVX Standard

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    15/127

  • 8/10/2019 Primary Offering 2010 10 - Morocco

    16/127

    Schneider Electric 27-Energy J. VAGNON 12/10/2010

    Up to 2500 A

    Up to 1250A

    Two cubicle width 600mm and 800mmTwo CB for the range

    Standard = IEC + GOST + 50/60Hz

    Open pole design

    Range optimised for 12kV and use at 17.5kV withadditional insulation material

    2 new VCBs based on standard components

    PIX Compact Truck with Vacuum Circuit

    Breaker HVX Compact