MiSeq The Most Accurate and Easiest to Use
Benchtop Sequencer in the World
2 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Upgraded MiSeqs ship fully loaded
– Hardware
Compensator
Syringe
PC
– Software
MCS2.0
Upgraded MiSeqs Started Shipping August 7, 2012 Customers are talking!
3 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
The MiSeq Trade-In Program is in the News
Illumina’s trade-in program was a
‘win-win’ for my lab. Demand for 454
had decreased and the box was
more expensive to operate than
other platforms.
Shrikant Mane, Yale core
The labor that’s required to run the PGM
and GS Jr is immense and messy and
still too variable. With MiSeq we can with
high confidence set up a qPCR library
quant and set up a run in less than 30’
after library is generated.
Anonymous, Clinical Seq
4 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
What Our Customers are Saying About Their MiSeq
Upgrades
We achieved 8.9Gb output after our
MiSeq upgrade!
Pioner Hi-Bred
We achieved almost 10 Gb output on PhiX
after MiSeq upgrade and >80% Q30.
Shrikant, Yale
I believe that the 2x250 data gave us an assembly that was almost
exactly equivalent to a shotgun 454 FLX+ assembly in terms of
Contig number and N50 (though obviously cheaper and faster, and
The data are better for SNP calls with MiSeq)
Nick Bergman, NBACC/DHS
5 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
New Worldwide Grant Program!
What is it: MiSeq Grant Program
Who can apply: Anyone! Novice or experienced with NGS!
How to apply: Complete short abstract (500 or less words) on ILMN.com for
judging
6 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Prize Package
Three grants, each including:
– One (1) MiSeq system
– Ten (10) Sequencing reagent kits
– Choice of sample prep:
Nextera XT DNA Sample Prep (384 Samples) or
TruSeq Custom Amplicon (384 Samples)
– BaseSpace cloud computing analysis and storage
– Avadis NGS, a biologist-friendly bioinformatics desktop tool
7 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Judging Criteria, Timeline & Outbound Marketing
Scoring Criteria
– Scientific Merit
– Originality
– Fit with MiSeq
Timeline
– Campaign Launch: 8/22
– Submissions due: 10/15
– Internal Judging: 10/16 – 11/2
– ASHG Winner Announcement: 11/6
8 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
MiSeq v2 Chemistry Dramatically Improves Performance Longer Read Length, Same Great End-of-Read Quality
Quality scores at the 250th base with new chemistry similar to those at the
150th base with earlier chemistry (E. coli data)
Read 1 Read 2
9 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
MiSeq Reagent Portfolio Options at Every Read Length – Support for Multiple Applications
50-cycle 300-cycle 500-cycle
25bp
50bp
250bp 250bp
250bp 250bp
400bp 100bp
25bp 150bp 150bp
Single Read 50bp
–RNA-Seq,
–Chip-Seq
–Short Amplicon
Paired end 2x25bp
–Library QC
Paired end 2x150bp
–TSCA
–Small Genome de novo
–Standard Amplicon
Standard PE 2x250bp
Overlapping PE 2x250bp
(2x consensus in overlap)
Asymmetric PE generate
long (400+ bp) “fragment-
like” reads
150bp 150bp
Overlapping 2x150bp
– FFPE amplicon
10 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Easy Forward & Backward Compatibility Mix and Match v1 and v2 kits with both instrument types
MiSeq v2 reagents are compatible with
legacy instruments
– Requires MCS 2.0 (available now!)
– Enables 2x250bp sequencing
– Single surface imaging only
MiSeq v1 reagents can be run on
upgraded MiSeq instruments
– Single surface imaging only
– v1 specifications
MiSeq
Instrument
Upgraded
MiSeq
MiSeq Kit v1
MiSeq Kit v2
Up to 1.5Gb
Up to 2x150
Up to 2.5Gb
Up to 2x250
Up to 7.5Gb
Up to 2x250
Up to 1.5Gb
Up to 2x150
12 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
MiSeq Continuous Performance Improvements
Up to 4 M clusters/run
Up to 2 x 250 bp read length
ETA: late Q4 2012
100’s Mb
7 Gb
1-1.5 Gb
Gb
15-17 M clusters/run
2 x 250 bp read length
4.4-5.1 Gb at 2 x 150
7.5-8.5 Gb at 2 x 250
<5 min cycle time
5-7 M clusters/run
2 x 150 bp read length
5 min cycle time
• Read lengths get longer
- 66% increase
• Output grows
- 3 fold improvement
in number of clusters run
13 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Setting New Standards in Benchtop Sequencing MiSeq is the most accurate and easiest to use benchtop sequencer in the world
Greater sequencing coverage for somatic mutation detection in gene panels
Higher multiplexing capability for sequencing of bacterial genomes
Improved de novo assembly of small genomes
Profile several gene expression samples per run
That’s almost 6Gb of Q30 data!
14 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
MiSeq System Performance Improving System Utility
Key Improvements
– Chemistry
Faster Clustering
Faster PE Chemistry
Faster SBS Cycle Time ~2 min
chemistry
– Yields Faster Run Times
– Hardware
More imageable area (dual surface)
Faster onboard PC
– Software
Illumina Experiment Manager
MiSeq Control Software
Real Time Analysis
MiSeq Reporter
16 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Accelerated Flow Cell scanning (through partial scanning of FC)
Faster run times!
Improved workaround for RFID read failures
Less customer complaints
Optional email notification for
RTA completion
MiSeq Reporter analysis completion
Fatal error during sequencing
Post-run wash now required to ensure extended life of MiSeq valves
MiSeq Control Software
17 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Improved speed & performance (up to 35% improvement)
New user interface with better performance and improved graphics
Improved sample sheet validation before analysis
User can edit sample sheet on the fly through the user interface
New default aligner/variant caller:
MiSeq Reporter
Workflow Default Aligner Default Variant Caller
Resequencing BWA GATK
Custom Amplicon (TSCA) Banded Smith-
Waterman
GATK
PCR Amplicon (Nextera) BWA GATK
Library QC BWA N/A
*Can switch back to old Eland/Starling through config setting
18 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
RTA v1.16
Improved low diversity detection logic
If low diversity detected, switch to new matrix/phasing logic to improve detection
Address low diversity challenges especially for 16S metagenomics
BaseSpace Broker v2.0
Status of run (e. Paused, stopped) communicated to BaseSpace
Users can monitor run in real-time through BaseSpace via browser (no need for SeqMonitor)
Avadis NGS desktop software for Amplicon, RNA-Seq, ChIP-Seq, Small RNA analysis
ILMN customers get discount to Avadis software license http://bit.ly/IlluminaNGS
RTA, BaseSpace, and Avadis NGS
MiSeq instruments connected to BaseSpace will automatically receive Updater
Customers can manually update via Updater available at MyIllumina:
(http://icomadmin/Download/Edit/iHJn1IjhlUC9Wf63yynCrg)
20 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
MiSeq Hardware Upgrades
Upgrade Part Part Function Benefits
Single Board
Computer(SBC)
Controls image processing
and data analysis
Improved computational ability
to handle increased system
output
Compensator
Lens
Enables dual-surface
imaging of the flowcell
Higher output by running 14
tiles on top and bottom
surfaces.
Reagent valve
and syringe
Valve responsible for
reagent delivery to the
flowcell
Improved robustness when
used with new auto-wash
recipe in MCS.
21 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Start MiSeq Upgrade
Pre-Upgrade Activities
Upgrade SBC Board/E-box
hardware
Replace the hard drive
Install and adjust the
compensator
Upgrade the syringe
Restore and configure files
Qualify the Upgrade
All done!
MiSeq Upgrade Workflow: ~ 1 day to complete
Valve Swap if needed
23 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
New Features for TruSeq Custom Amplicon (TSCA) Available August 31st
Increased plexity up to 1,536 amplicons per reaction – designs
covering up to ~600 kb of total content
More flexible amplicon sizes – smaller to enable custom panel support
for FFPE, and larger to take advantage of 2 × 250 bp read lengths
supported on the MiSeq system
Designs for non-human genomes – Early access to selectable
reference genomes for mouse, rat, and bovine
24 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
MiSeq improvements empower applications
What do 15M clusters and 2x250 bp reads give you?
Amplicon-based applications
– Larger TSCA up to 1,536
amplicons
– Higher sample throughput for
smaller amplicon panels
– Deeper coverage for rare somatic
mutations
– Larger amplicons
– Bidirectional sequencing of
smaller amplicons <250 bp for
ultimate confidence in results
Small Genomes
– Higher sample throughput per run
– Better de novo assemblies
– Larger insert Nextera XT protocol
coming soon!
26 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
RNA-Seq Applications
GEx Profiling Transcriptome Analysis
“Gene” level fold change
High Reproducibility
Simple Analysis
• 50 bp , SR or PE
• 5 – 10M reads
Discovery
Diff exp. of alt. transcripts
Detection of cSNPs, gene
fusions
• 50-75 bp, PE
• 50-100M reads
27 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
70
MiSeq 2 output will dramatically increase demand for RNA analysis
Increased output attractive to larger customer base
Fits broader range of study designs, including small mammalian studies
Competitive environment heavily pushing replacement for GEx arrays
5-10 M reads of 50 bp length from mRNA will give performance better than
any microarray
Paired end capabilities only available on MiSeq!
RNA-Seq application important for MiSeq
70 70
28 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Introducing TruSeq ChIP Sample Prep
(Shipping Aug. 2012)
Directly MiSeq Compatible
Multiplexed ChIP-Seq analysis
– 24 unique indexes
Streamlined workflow
Low sample input requirement (5ng)
Only $54 per sample!!
– >75% reduction relative to
legacy
Offers multiple improvements over current ChIP-Seq Sample Prep kits!
29 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Introducing Nano and Micro MiSeq Reagent Kits
Cost‐effective pricing for the amount of output that is
“just right”
31 COMPANY CONFIDENTIAL – DO NOT DISTRIBUTE
Compatibility Matrix
HW
upgraded? SW
version
Reagent
version Kit size
Clusters PF
(M) Paired
End Read Length
(bp) Output (Mb) Output (Gb)
no MCS
1.2 1
50-cycle 5 2 25 250 0.25
300-cycle 5 2 150 1500 1.5
no MCS
2.0 1
50-cycle 5 2 25 250 0.25
300-cycle 5 2 150 1500 1.5
no MCS
2.0 2
50-cycle 5 2 25 250 0.25
300-cycle 5 2 150 1500 1.5
500-cycle 5 2 250 2500 2.5
yes MCS
2.0 2
50-cycle 15 2 25 750 0.75
300-cycle 15 2 150 4500 4.5
500-cycle 15 2 250 7500 7.5