4
ProGrip self-gripping polyester mesh: specifically designed for suture-line reinforcement Actor Portrayal PREVENT HERNIAS. PROTECT PATIENTS.

PREVENT HERNIAS. PROTECT PATIENTS

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

ProGrip™ self-gripping polyester mesh: specifically designed for suture-line reinforcement

Actor Portrayal

PREVENT HERNIAS. PROTECT PATIENTS.

A NEWSOLUTIONFOR HERNIAPREVENTION.

EASY AND EFFECTIVE TO USEProGrip™ self-gripping polyester mesh helps prevent hernias after laparotomies.1,4 It’s also easy to use5-8 and:

· Provides excellent tissue integration9,†, ‡

· Limits the need for additional fixation7,10,†

Recommended for PreventionCompared with laparotomy closure, prophylactic mesh has been shown to effectively decrease the incidence of incisional hernias.11,12 That’s regardless of mesh location or composition and without significantly increasing the odds of wound morbidity.

Both the International Endohernia Society and the European Hernia Society favour the elective use of prophylactic mesh placement for high-risk patients.13,14

ProGrip™ self-gripping polyester mesh provides a spread and balanced fixation on the entire surface of the mesh. Surgeons — and their patients — can have confidence in a mesh that provides immediate fixation that’s strong and durable.2,3,†

† Additional fixation is at the surgeon’s discretion.‡ Animal data is not necessarily indicative of clinical

outcomes in humans.

RESORBABLE MICROGRIPSProvide immediate fixation with limited need for additional fixation1,4,10,†

SEMI-RESORBABLE MESHLeaves 50 percent of material after polylactic acid (PLA) absorption15,‡

MACROPOROSITYFavours better tissue integration and supports a lower foreign body reaction16-19,‡

Actor Portrayal

FOUR NEW SIZESFOR BETTEROUTCOMES.

Device classificationIntended for use in reinforcement of soft tissue where weakness exists, in procedures involving abdominal suture-line reinforcement.20

Material compositionBicomponent mesh constructed of hydrophilic monofilament polyethylene terephthalate (PET) knit with resorbable polylactic acid (PLA) microgrips.

FixationSelf-gripping over 100 percent of surface area.

Pore size20

1.1 mm to 1.7 mm.

Weight20

72 g/m² (before absorption) 39 g/m² (after absorption).

† Additional fixation is at the surgeon’s discretion.

The ProGrip™ self-gripping polyester mesh has dedicated sizes that offer a benefit to surgeons — prevention of incisional hernia with an optimal width for suture-line reinforcement.

10 x 8 cm

20 x 8 cm

30 x 8 cm

40 x 8 cm

References1. Blazquez Hernando LA, Garcıa-Urena MA, Lopez-Monclus J, et al. Prophylactic mesh can be used safely in the prevention of incisional hernia after bilateral subcostal

laparotomies. Surgery. 2016;160(5):1358–1366.2. Hopson SB, Miller LE. Open ventral hernia repair using ProGrip™ self-gripping mesh. Int J Surg. 2015;23(Pt A):137–140.3. Kapischke M, Schulze H, Caliebe A. Self-fixating mesh for the Lichtenstein procedure –– a prestudy. Langenbecks Arch Surg. 2010;395(4):317–322. This study was conducted

with Parietene ProGrip™ mesh.4. Sværdborg M, Damsgaard TE. Donor-site morbidity after pedicled TRAM breast reconstruction: a comparison of two different types of mesh. Ann Plast Surg. 2013;71(5):476–80.5. Based on internal test report #CDP-0007577-CR002, Design inputs. 2017.6. Based on internal test report #MC2009-004CR020, Functional trial: preclinical study report. 2010.7. Based on internal test report #0607CR027, Comparative test of gripping power in pigs. 2008.8. Based on internal test report #0607CR023, In vivo testing of Parietex™ ProGrip™ mesh. 2008.9. Hollinsky C, Kolbe T, Walter I, et al. Comparison of a new self-gripping mesh with other fixation methods for laparoscopic hernia repair in a rat model. J Am Coll Surg.

2009;208(6):1107– 1114. This study was conducted with Parietene ProGrip™ mesh.10. Verhelst J, de Goede B, Kleinrensink GJ, Jeekel J, Lange JF, van Eeghem KH. Open incisional hernia repair with a self-gripping retromuscular Parietex™ mesh: a retrospective

cohort study. Int J Surg. 2015;13:184–188.11. Wang XC, Zhang D, Yang ZX, Gan JX, Yin LN. Mesh reinforcement for the prevention of incisional hernia formation: a systematic review and meta-analysis of randomized

controlled trials. J Surg Res. 2017;209:17–29.12. Dasari M, Wessel CB, Hamad GG. Prophylactic mesh placement for prevention of incisional hernia after open bariatric surgery: a systematic review and meta-analysis. Am J Surg.

2016;212(4):615–622.e1.13. Bittner R, Bingener-Casey J, Dietz U, et al. Guidelines for laparoscopic treatment of ventral and incisional abdominal wall hernias (International Endohernia Society [IEHS])-Part III.

Surg Endosc. 2014;28(2):380–404.14. Muysoms FE, Antoniou SA, Bury K, et al; European Hernia Society. European Hernia Society guidelines on the closure of abdominal wall incisions. Hernia. 2015;19(1):1–24.15. Based on internal test report #RAT021, PLA degradation report. 2014.16. Weyhe D, Cobb W, Lecuivre J, et al. Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage: systematic analysis of

key parameters of meshes in a novel minipig hernia model. Int J Surg. 2015;22:46–53.17. Ventral Hernia Working Group, Breuing K, Butler CE, Ferzoco S, et al. Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique

of repair. Surgery. 2010;148(3):544–558.18. Lake SP, Ray S, Zihni AM, Thompson DM Jr, Gluckstein J, Deeken CR. Pore size and pore shape — but not mesh density — alter the mechanical strength of tissue ingrowth and

host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair. J Mech Behav Biomed Mater. 2015;42:186–197.19. Based on internal test report #Type GT8 textile TEX014, justifying for the pore size. 2015.†20. ProGrip™ self-gripping polyester mesh [instructions for use]. Trévoux, France: Sofradim Production; 2017.

ORDERING INFORMATION

To learn more about

ProGrip™ self-gripping polyester mesh, contact us under the country specific phone number below.

Ordering code Size Shape

TMP1008G 10 x 8 cm Rectangle

TMP2008G 20 x 8 cm Rectangle

TMP3008G 30 x 8 cm Rectangle

TMP4008G 40 x 8 cm Rectangle

© 2020 Medtronic. All rights reserved. 20-weu-progrip-new-mesh-sizes-4547276

medtronic.com/covidien/uk

Medtronic Limited Building 9, Croxley Park, Hatters Lane, Watford, WD18 8WW United Kingdom Tel: +44 (0)1923 212213 Fax: +44 (0)1923 241004

Medtronic Danmark A/S Arne Jacobsens Allé 17, 7. sal DK-2300 København S [email protected] Customer service DK, +4532481810 Customer service Nor, +4767103202 Customer service Swe, +46856858510 Customer service Fin, +358207281210

Medtronic Trading Nl BV Larixplein 4 5616 VB Eindhoven The Netherlands Customer service, +31(0)40 711 7555

Actor Portrayal