4
Pc Pressurecheck A compact water supply, designed to boost your system back into full compliance.

Pressurecheck Brochure 071016 - Project Fire ProductsBrochure.pdf · construction work, extensive planning & co-ordination and costly visits (and re-visits) by electricians, ... Pressurecheck™

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Pressurecheck Brochure 071016 - Project Fire ProductsBrochure.pdf · construction work, extensive planning & co-ordination and costly visits (and re-visits) by electricians, ... Pressurecheck™

Pc

Pressurecheck

A compact water supply, designed to boost your system back into full compliance.

Page 2: Pressurecheck Brochure 071016 - Project Fire ProductsBrochure.pdf · construction work, extensive planning & co-ordination and costly visits (and re-visits) by electricians, ... Pressurecheck™

Pressurecheck is our highly engineered compact water supply solution designed to bring your sprinkler system back into full compliance.

Taking up roughly two car parking spaces, Pressurecheck is a very compact alternative to a pump and tank system. Pressurecheck works by drawing water from the town-mains supply to feed a sprinkler system which cannot reliably meet the minimum pressures required for a specific risk. It can also be used as a direct alternative to traditional pump and tanks systems, increasing valuable revenue space and streamlining installation.

As Pressurecheck is built and fully tested in our factory, it can be delivered and installed quickly with minimal disruption. Offering a unique plug-and-play design means that installation time and overall costs are dramatically reduced.

Code CompliantFire protection regulations specify that sprinkler systems must be supplied at a minimum pressure appropriate to the fire risk. Any reduction in town main pressure can render a fire protection system non-compliant.

Pressurecheck boosts the sprinkler system pressure in situations where the towns-mains pressure is unsuitable and has been designed as an engineering solution to meet code standards (clause 9.2.2 (BS EN12845:2015)).

Pressurecheck has a WRAS approved back-flow prevention system with a reduced pressure zone (RPZ), this means that no water that enters the sprinkler system will be able to contaminate the drinking water supply.

Space SavingIn an increasingly crowded world, where space is at a premium, space saving solutions are becoming essential. Not only does Pressurecheck deliver massive space savings, it also simplifies the project planning, installation and commissioning stages.

In most cases, traditional pump and tank solutions often require lengthy installation periods, involving construction work, extensive planning & co-ordination and costly visits (and re-visits) by electricians, fitters and tank engineers etc.

Pressurecheck, however, is pre-built in the factory and arrives fully pre-wired and tested, ready to be connected to the sprinkler system.

Many of the headaches traditionally associated with contracting can be eradicated by using Pressurecheck and because of the off-site nature of the product, we can dramatically reduce the on-site costs normally caused by snagging issues and complications that invariably crop up.

• Space saving• Plug-and-play design• 100% factory assembled and tested• Easy delivery• BS EN12845 code compliant• Quick and easy on-site installation• Fully pre-wired• Simplified project planning• WRAS approved system• LPCB appoved equipment• Perfect alternative to pump and tanks

systems• Modular - can fit through a standard

size doorway• Reduced on-site costs

Looking for a way to boost the water supply to your sprinklers?

Page 3: Pressurecheck Brochure 071016 - Project Fire ProductsBrochure.pdf · construction work, extensive planning & co-ordination and costly visits (and re-visits) by electricians, ... Pressurecheck™

Under normal operating conditions the sprinkler system is supplied via the town-mains. The blue route shows water from the town-mains ‘A‘ passing through the RPZ ‘B‘ and supplying the sprinkler system connected at ‘C‘. Should the town-mains supply drop below the required pressure, route 2 is automatically initiated. The pump ‘D‘ is activated, drawing water from the AVC (Anti Vacuum Chamber) ‘E‘. The town main then refills the AVC via the high capacity float valves ‘F‘.

How it Works

Space saving - Pressurecheck roughly takes up two car parking spaces, ideal for buildings with limited access or space.

Sustainability - No new building/or pump house is required giving massive savings in construction materials, multiple site visits, building waste and disruption.

Modular design - Pressurecheck can be broken down into parts for easy delivery and positioning in-situ (each part fits through a standard size door).

Quick and easy installation - It’s unique plug-and-play design means that installation time and overall costs are dramatically reduced.

Compliant - Pressurecheck is BS EN12845 compliant, WRAS approved and only uses LPCB approved components.

Factory assembled and tested - Simplifies the projects planning, installation and commissioning stages.

System Highlights

Towns main supply

Fire pump boosted

E

C

D

AB

F

Pressurecheck is always able to maintain the correct system operating pressure even when mains pressure is unreliable.

Page 4: Pressurecheck Brochure 071016 - Project Fire ProductsBrochure.pdf · construction work, extensive planning & co-ordination and costly visits (and re-visits) by electricians, ... Pressurecheck™

Quality Design & BuildEvery Pressurecheck is fully assembled, wired and tested before it leaves the factory. Assembled in a tightly controlled manufacturing environment, every model is subjected to a set programme of stringent quality inspections. The unit is fully air and water tested before arriving on-site and because all the wiring has been completed in-house, the unit arrives ready for installation.

Pressurecheck incorporates only LPCB and WRAS compliant components. All the pipes and components are safely protected and supported by five purpose-built, corrosion resistant steel frames. Each frame has been coated using a thermoplastic powder to ensure it’s fully protected to operate in damp or hazardous environments.

Modular DesignPressurecheck’s smart design enables the unit to be disassembled into small sections (see diagram below)capable of fitting through a single door frame. This makes it ideal for existing buildings with limited access. When in position, the sections can be easily re-assembled and connected up ready for commissioning.

Pressurecheck™ is a registered product name of Project Fire Products Ltd. We reserve the right to change product specifications as a part of our continuous improvement policy. This document is Copyright and the property of Project Fire Products Ltd and must not be copied or reproduced without its written permission.

Designed and manufactured in the UK by Project Fire Products Ltd. Patent pending 2280368.

Project Fire Products LtdPasturefields Industrial Estate Pasturefields LaneHixonStaffordshireST18 0PH

System DesignPressurecheck SystemOur Pressurechecks come pre-configured to your buildings requirements, rated at either OH1, OH2 or OH3 hazard classification with a 15m, 30m or 45m rated fire pump determined by the highest sprinkler head on the installation.

The unit is pre-wired and assembled in our factory, fully tested and can then be disassembled into separate sections for delivery to site and easy on-site installation.

Volumetric/ModularOur Pressurechecks can be built as either volumetric (one piece) or modular units designed to fit through a standard single door frame if site access is an issue.

SizeThe Pressurecheck unit and its compact design takes up a floor space of approximately 3.5x3.5 metres with a ceiling height of 3 metres depending on the system configuration.

01889 271 [email protected]

(Picture for illustrative purposes only)