www.iso-therm.com
V E R T IC A L A C C U M U L ATO R S
12 3/41416182024303642485460667278849096
848484849696969696
108120120120144144144144144
2233445688
1010101012121212
B2233445688
1010101012121212
AOAHDIA.MODEL DIMENSIONS (INCHES)
TEMPERATURE F
AV370445535575670845
105012102010256031504520587075008000
102501312016700
SHIP WEIGHT (Ib)
VOL³)
*LOAD(TR)
5.047.028.84
11.3114.8920.9132.8547.0967.8592.25
140.12171.02204.22298.20351.11408.35473.10539.76
2937486276
110175254347456576714864
10321215141316081835
Level Column NPS: 1 1/4".
Aspirating option available.Boil-out or subcooling coil if required.
Vent/Drain NPS: 3/4" x 3000# F- CPLG.Horizontal orientation an option.
*Ammonia @ 0°F. For other saturation temperature & refrigerants use the table below.
o
REFRIGERANTR-717R-22
R-744R-507a
401.501.00
-0.63
301.390.93
-0.58
201.250.892.200.55
101.130.802.100.50
01.000.741.970.46
-100.860.671.820.42
-200.720.581.690.36
-300.600.501.540.31
-400.480.431.410.27
-500.380.351.270.22
D1
A
C
BE1
OAH
18”TYP.
A:B:C:D:E:
InletOutletLiquid Make-upRelief/DrainLevel Column
DIA.
PERFORATED PLATE
E2
D2
www.iso-therm.com
TEMPERATURE F
12 3/41416182024303642485460667278849096
848484849696969696
108120120120144144144144144
2233445688
1010101012121212
B2233445688
1010101012121212
AOAHDIA.MODEL DIMENSIONS (INCHES)
AV370445535575670845
105012102010256031504520587075008000
102501312016700
SHIP WEIGHT(Ib)
VOL³)
*LOAD(TR)
5.047.028.84
11.3114.8920.9132.8547.0967.8592.25
140.12171.02204.22298.20351.11408.35473.10539.76
2937486276
110175254347456576714864
10321215141316081835
Level Column NPS: 1 1/4".
Subcooling coil if required.
Vent/Drain NPS: 3/4" x 3000# F- CPLG.Horizontal orientation an option.
*Ammonia @ 0°F. For other saturation temperature & refrigerants use the table below.
o
REFRIGERANTR-717R-22
R-744R-507a
401.501.00
-0.63
301.390.93
-0.58
201.250.892.200.55
101.130.802.100.50
01.000.741.970.46
-100.860.671.820.42
-200.720.581.690.36
-300.600.501.540.31
-400.480.431.410.27
-500.380.351.270.22
V E R TIC A L IN TER C O O LER
B
F1 B E1 F1
E
A
F2
C
OAH
A:B:C:D:
InletOutletLiquid Make-UpDrop Leg
DIA.
DIA.
OAL
E2
D
E2 C A D
E1, E2: Relief/DrainLevel ColumnF1, F2:
HORIZONTAL
VERTICAL
TEMPERATURE F o
REFRIGERANTR-717R-22
R-744R-507a
401.501.00
-0.63
301.390.93
-0.58
201.250.892.200.55
101.130.802.100.50
01.000.741.970.46
-100.860.671.820.42
-200.720.581.690.36
-300.600.501.540.31
-400.480.431.410.27
-500.380.351.270.22
S UR G E V E SS EL S
www.iso-therm.com
MODEL*HSV/VSV DIA. OAL/OAH A B C D E1, E2
DIMENSIONS (INCHES) **CAPACITY(TR)
SHIP WEIGHT(lb)
Level Column NPS: 1 1/4".
*HSV is for horizontal surge vessel, while VSV is for vertical surge vessel.
Split flow design an option.
12041605200624063008360842104810541260126612721278138413
12 3/416202430364248546066727884
486072729696
120120144144144144156156
334448888
1010101010
2233455668888
10
3/43/41
1 1/41 1/2
222
2 1/22 1/2
3333
334448888
1010101010
3/43/43/43/43/43/43/43/43/43/43/43/43/43/4
20355585
120175250325470585700850
10001160
250400600700
115014002000260035004800620075008200
10500
**For Ammonia @ 0 F . Other saturation temperature & refrigerants use the following table. o
BDCA
A:B:C:D:
InletOutletVentRelief
DIA.
OAL
OIL P O TS
www.iso-therm.com
SIDE VIE WELEVATION VIEW
L EVE L C OL UM N S
1/2” DRAIN CPLG.
STD. 1 1/2”LEVEL EYE
TYP.
3/4” FLOATCONNECTION
OPTIONALPROBE CPLG.
1 1/4” COLUMNCONNECTION
TYP.
STD. NPS is 3”; Larger Diameter offered if required. For other requirements, please contact the factory.
STD. 3” NPS
DIMENSIONS (INCHES) SHIP WEIGHT(lb)
VOL( ³)DIA.
6 5/88 5/8
10 3/412 3/4
MODELOP
OP-603OP-803
OP-1003OP-1203
OAL36363636
A3/43/43/43/4
B3/43/43/43/4
C3/43/43/43/4
D3/43/43/43/4
5595
135185
0.551.001.541.91
Heater connection offered if required.
A
E1 D E2
E1 D B C1E2
E3
E3
C2
C1
C2
B
A
A:B:
C1, C2:D:
E1:E2:E3:
Liquid InletLiquid OutletLevel ColumnEqualPurgeReliefDrain
DIA.
OAL
OAHDIA.
18”TYP . VERTICAL
HORIZONTAL
HIGH PRESSURE RECEIVERS
www.iso-therm.com
DIMENSIONS (INCHES) SHIP WEIGHT(lb)
**PUMP DOWN(lb) R-717
VOL.( ³)
MODEL*RH/RV DIA. OAL / OAH A B D E1 E2 E3
12081212141014121610161218121814201220142412241424163014301630183616361842164218481648185416541860186020721872208418842096189620
12 3/412 3/4
141416161818202024242430303036364242484854546060727284849696
96144120144120144144168144168144168192168192216192216192216192216192216216240216240216240216240
3/4 3/43/411
1 1/41 1/41 1/41 1/2
22 1/22 1/2
333333344455666688
1010
1/2 1/2 1/2 3/4 3/4
1111
1 1/41 1/41 1/41 1/41 1/21 1/21 1/21 1/21 1/21 1/2
222
2 1/2333334455
1/21/23/43/43/43/41111
1 1/41 1/41 1/42 1/22 1/22 1/22 1/22 1/22 1/2 2 1/2 2 1/22 1/22 1/22 1/2
33335555
1/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/21/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
1/21/21/21/21/21/21/21/21/21/23/43/43/43/43/43/43/43/43/43/43/43/43/43/41111
1 1/41 1/41 1/41 1/4
1/21/21/21/21/21/21/21/21/21/23/43/43/43/43/43/43/43/43/43/43/43/43/43/41111
1 1/41 1/41 1/41 1/4
6.139.33
10.7112.7113.6116.4121.0024.6025.6228.8236.0542.2548.4566.4776.2766.08
109.94124.14148.00167.20193.19218.38241.10272.90334.77373.97480.12535.32645.41723.57832.42927.38
180273314372399481615721751844
105612381420194722342522322136374336489856606398706379959810
10955140241562018765211252432726996
430640610720690820930
1080103011901240143016201800203022702450274028903220439048904950552077208510
121001350016725184212212624178
*RH: Horizontal receiver; RV: Vertical Receiver. ** Capacity based on 80% full at 96°F. Level Column NPS: 1 1/4".
DIMENSIONS (INCHES) SHIP WEIGHT(lb)
MODEL*RHTS/RVTS **CAPACITY (MBH)
DIA. OAL / OAH A, B D EC804
1004120514061606180620062407300736074208
143228405575765960
12001900297046707560
8 5/810 3/412 3/4
1416182024303642
4848607272727278788496
1 1/41 1/2
22 1/2
3345688
1 1/21 1/2
22 1/2
3344568
22
2 1/234455688
1 1/41 1/2
22 1/2
3344568
100130190360410450510660830
14002000
E
E
D
C
C
BA
A
D
A:B:C:D:E:
Liquid refrigerant inlet from condenserLiquid refrigerant overflow to receiverLiquid return to thermosyphon coolerReturn from thermosyphon coolerGas return to condenser
DIA.
OAL
OAH
DIA.
1/2” RELIEF
VERTICAL
HORIZONTAL
B
1/2” RELIEF
T H E R M O S Y P H O N R E C EIVE R S
www.iso-therm.com
*RHTS: Horizontal receiver; RVTS: Vertical receiver.** Capacities listed are for R-717. For R-22, multiply heat of rejection by 0.70. For R-507a, use multiplier of 0.67.
www.iso-therm.com
MODELRVTS
DIA. OAH A B C D E G/H/J/K STANDPIPEEMPTY
WEIGHT(lb)301236124216481654166016721884189618
303642485460728496
144144192192192192216216216
45556688
10
1 1/21 1/2
2233345
344455668
45556688
10
344455668
3/4 3/4 3/4 3/4 3/4
11
1 1/41 1/4
688888
101010
200027003600440065007300
100001300016000
E HJ
G
A
F1
F2
C
K
B
D
A:B:C:D:E:
F1,F2:G:H:J:K:
Liquid inletLiquid outletTS supplyTS returnEqualizationLevel columnDrainReliefVentTSOC drain
DIA.OAH
18”TYP.
STANDPIPE
HIGH PRESSURE THER M OSYP HO N RECEIVERS
www.iso-therm.com
Dimensions are in inches.Level Column NPS: 1 1/4”.Horizontal orientation an option.
www.iso-therm.com
E1
F
L
K
A
G1
G2
G3
M
C
J
H
B
E2
D
A:B:C:D:
E1,E2:F:
G1,G2,G3:H:J:K:L:M:
Gas inletGas outletOil outletReliefBlowdownOil returnSight glassTemp. transmitterOil drainOil returnUpper transmitterOil heater
VERTICAL COALESCING OIL SEPARATORS
www.iso-therm.com
Coalescing elements to be supplied by customer. If not, please contact the factory.Horizontal orientation an option.Prefix for vertical model: CSV; For horizontal: CSHStainless demister pad offered if required. Angle supports are standard; others offered if required. Standard 20” OD manway with davits offered; other options offered if required. Following information required for quotation:
Gas flow rate (mass or volume) Suction temperature Discharge pressure Gas composition (type, molecular weight, etc.)
Typical diameters range from 16” OD to 60” OD. For larger diameter, please contact the factory.
www.iso-therm.com
B
C
A
FP
PKGHEIGHT
A:
B:
C:
D:
Wet return
Dry suction
Liquid make-up
Pump suction
DIA.
OAL
D1 D2
FRONT VIEWSIDE VIEW
HORIZONTAL PUMP RECIRCULATORS
www.iso-therm.com
MODELHPR
DIA. OAL *PKGHEIGHT
*BASELENGTH A B DC FP*BASE
WIDTHCAPACITY
(TR)SURGE VOL
³)EMPTY
WEIGHT(lb)OPERATINGWEIGHT(lb)
2412301236124212481254126013721384149614
108151201514416
24303642485460728496
108120144
144144144144144144156156168168180180192
9096
102108114120126138156168180192216
156156156156156156168168180180196196204
3642485460727890
102114132144168
556688
10121212121616
456688
10101012121416
11 1/41 1/41 1/41 1/21 1/2
22 1/22 1/2
3344
44444566888
1012
222
2 1/22 1/2
33346668
85135195280365530650940
13501770225027804000
11182942597187
125182241340411637
31003500390050006400750080009200
1100015000182002050040000
42004400530070009200
1100012500162002400035000455005500091000
LW
o
Bare vessels also available.*Base length, base width, & package height may vary.Dimensions in inches.
TEMPERATURE F o
REFRIGERANT SINGLE STAGE TWO STAGE40
1.501.00
-0.63
R-717R-22
R-744R-507a
301.390.93
-0.58
201.250.892.200.55
101.130.802.100.50
01.000.741.970.46
-100.860.671.820.42
-101.000.741.970.46
-200.890.691.890.44
-300.750.601.760.38
-400.600.501.540.31
-500.500.451.470.28
AMMONIA FLOW, gpm/TROVERFEED RATE TEMPERATURE F
400.1410.2120.2830.423
2: 13: 14: 16: 1
300.1370.2060.2750.412
200.1340.2010.2680.401
100.1310.1960.2610.391
00.1270.1910.2540.382
-100.1240.1860.2490.373
-200.1210.1820.2430.364
-300.1190.1780.2330.356
-400.1160.1740.2320.349
-500.1140.1710.2280.342
D1
PKGHEIGHT
A:B:C:D:
Wet returnDry suctionLiquid make-upPump suction
OAH
A
D2
B
C
FP
DIA.
FRONT VIEWSIDE VIEW
TEMPERATURE F o
REFRIGERANT SINGLE STAGE TWO STAGE40
1.501.00
-0.63
R-717R-22
R-744R-507a
301.390.93
-0.58
201.250.892.200.55
101.130.802.100.50
01.000.741.970.46
-100.860.671.820.42
-101.000.741.970.46
-200.890.691.890.44
-300.750.601.760.38
-400.600.501.540.31
-500.500.451.470.28
AMMONIA FLOW, gpm/TROVERFEED RATE TEMPERATURE F
400.1410.2120.2830.423
2: 13: 14: 16: 1
300.1370.2060.2750.412
200.1340.2010.2680.401
100.1310.1960.2610.391
00.1270.1910.2540.382
-100.1240.1860.2490.373
-200.1210.1820.2430.364
-300.1190.1780.2330.356
-400.1160.1740.2320.349
-500.1140.1710.2280.342
VERTICAL PUMP RECIRCULATORS
www.iso-therm.com
MODELHPR
DIA. OAL *PKGHEIGHT
*BASELENGTH A B DC FP*BASE
WIDTHCAPACITY
(TR)SURGE VOL
³)EMPTY
WEIGHT(lb)OPERATINGWEIGHT(lb)
2410301036114211481254126013721384149614
108151201514416
24303642485460728496
108120144
120120132132144144156156168168180180192
186186198198210210222222234234246246258
606672788496
102114126138156168192
3642485460727890
102114132144168
556688
10121212141618
456688
10101012121416
11 1/41 1/41 1/41 1/21 1/22
2 1/22 1/2
34 4 4
4444556688
101012
2223333446688
106142223300389496658907
13151660222526404408
162436486882
111137192244324381500
28003200390048006100680075008500
1100013800180002000033500
4400 4800 5800 8400
10800 13000 14800 18500 27500 37500 47300 50000 91800
W L
o
Bare vessels also available.*Base length, base width, & package height may vary.Dimensions in inches.
P U M P R E CIR C U L ATO R PA C K A G E S
www.iso-therm.com
ASME Design; 250# for Recirculator, 300# for Oil Pot @ MDMT of -20 F to 300 F Dual Relief Valve for Recirculator, Single Relief Valve for Oil Pot Spring Drain Valve for Oil Pot Level Column with the following: Level Eyes High level float switch 1 1/4’’ Isolation Valves Level Probe
2 pumps offered: 1 for operation and other as a standby Liquid Makeup Assembly
Solenoid, strainer, hand expansion valve with bypass loop and Isolation valves Motorized valve or hand expansion valve
Piped and mounted on steel skid Pressure tested per ASME; PED option with CE nameplate available 1 coat standard shop primer
Other options offered, but not limited to: Controller installed in NEMA 4 Box Isotherm PLC based control panel with starters NEMA control box with wiring Multiple float switches Post Weld Heat Treatment Third Pump connection for expansion Dual Pressure rating Design for shipment in two pieces with flanges, if required For other requirements, please contact the factory
www.iso-therm.com
HORIZONTAL VERTICALThe following lists Isotherm’s standard design:
PLATE EXCH A NGER PACKAGES
www.iso-therm.com
The following lists Isotherm’s standard design:
www.iso-therm.com
ASME Design; 250# for PHE, 300# for Oil Pot @ MDMT of -20°F to 300°F Dual Relief Valve for PHE Package, Single Relief Valve for Oil Pot Spring Drain valve for Oil Pot
Level Column with the following: Level Eyes High level float switch 1 1/4” isolation valves Level Probe
Liquid Makeup Assembly Solenoid, strainer, hand expansion valve with bypass loop & isolation valves Motorized valve or hand expansion valve
Piped and mounted on steel skid Pressure tested per ASME; PED option with CE nameplate available 1 coat standard shop primer
Other options offered, but not limited to: Controller installed in NEMA 4 box Isotherm PLC based control panel with starters NEMA control box with wiring Post Weld Heat Treatment of Surge Vessel For other options, please contact the factory
Please refer to our Plate-and-Frame (PHE) brochure for the various sizes of PHE’s and Surge Vessels.
Corporate Office:7401 Commercial Blvd. EastArlington, Texas 76001United States of AmericaPhone: +1 817 472 9922Fax: +1 817 472 5878E-mail: [email protected]
South America Office:El Salvador 275Santa PatriciaLa Molina, LimaPhone: +51 1655 1134Cell: +51 986612443E-mail: [email protected]
Middle East Office:702- Siddiq Trade Centre72- Main BoulevardGulberg Lahore, Pakistan Phone: +92 42 357 87689Cell: +92 345 765 6313E-mail: [email protected]
www.iso-therm.com
Other types offered are:
Low Pressure Receivers Pilot Receivers Liquid Transfer Packages