Upload
others
View
45
Download
0
Embed Size (px)
Citation preview
d u n a n s e n s i n g . c o m
MKT00010 Rev. A, 20175.1.17 v6.1
Pressure Transducers
Catalog
Our company….
DunAn Sensing LLC is a Silicon Valley, Calif., based company
founded in 2014. Our leadership and many members of our
engineering staff have a long track record in the MEMS pressure
sensor industry. We offer high-performance OEM pressure
sensors, transducers, and transmitters, which are sealed and
compatible with harsh media.
Our pressure sensor products do not require isolation from the
media that are being measured unlike traditional-type packages
that require welded metal membranes and cavities to be filled
with oil. The simpler construction of our pressure sensing
solution, which is based on our introduction of DURAsense™, an
innovative MEMS packaging technology which eliminates the
need for the traditional method of metal diaphragm welding
and oil-fill to achieve media-compatibility, provides superior
Accuracy, Reliability, and Affordability.
Our low-cost OEM pressure sensor can be manufactured in
standard packages and can also be customized to fit any specific
application for which we recommend you to work with one of
our Custom Engineering specialists.
2
d u n a n s e n s i n g . c o m
A c c u r a c y
Rel iabi l i ty
Affordability
The DURAsense® Difference
Sensitivity and Response Time
Durable and Harsh Media Compatible
Scalable and Customizable
•
3
d u n a n s e n s i n g . c o m
Table of Contents Page
AP Series 4
BP Series 5
HP & LP Series 6
IP Series 7
TP Series 8 - 9
VP Series 10
XP Series 11
Electrical Specifications 12
Application Schematic 13
Electrical Connection 14
Connector Pin Out(* TP Series only)
15*- 16
Part Number Ordering 17
Dimensional Drawings 18 - 26
Installation Note 27 – 28
CP Series New Product 29 – 36
Contact Information 37
Table of Contents
AP Series
Application Schematic
TP Series
Dimensional Drawings
HP & LP Series
Connector Pin Out (* TP Series only)
XP Series
CP Series New Product
BP Series
Electrical Connection
VP Series
Installation Note
IP Series
Part Number Ordering
Electrical Specifications
Contact Information
Page
4
13
8 - 9
18 - 26
6
15*-16
11
29-36
5
14
10
27 - 28
7
17
12
37
4
AP Series
Features Absolute or Sealed Gage Available in Aluminum, Brass, and
Stainless Steel Built-in Packard connector RoHS Compliant Extended Operating Temp Range
Applications Engine Oil Transmission Oil Fuel Pressure
The AP Series pressure transducers utilizes back-sidepiezo-resistive technology that is compatible with harshmedia and ideal for under-the-hood environment.
TECHNICAL SPECIFICATIONSAccuracy @ 25°CLinearity, repeatability, hysteresis, and calibration
±0.5 %Span
Total Error Band ±1.0 %Span 0°C to 80°C ±1.5 %Span -20°C to 125°C ±2.0 %Span -40°C to 140°C
Pressure Ranges 0-15 through 0-750 psi (absolute or sealed gage)
Operating Temperature Range -40°C to 140°C
Storage Temperature -40°C to 150°C
Proof Pressure 3X rated pressure (Maximum 1500 psi)
Burst Pressure 5X rated pressure (Maximum 2500 psi)
Cycle Life 10 Million + F.S cycles
Vibration 5g (33Hz)
Drop (any axis) 1 m
Housing Materials Aluminum, Brass, or Stainless Steel*
Electrical Connection IP67
Media Engine Oil, Fuel, Hydraulic, Non-corrosive gases
Sealing Material Viton (Consult Factory for other seal material options)
Approvals and Marks (UL Listed File E480159, Class III)
4
OUTPUT OPTIONS (See Electrical Specifications page 12 for details)
Ratiometric 0.5-4.5VDC (typical) *
Absolute Voltage 0-5VDC1-5VDC0-10VDC
Current Loop 4-20mA
* Standard
5
BP SeriesFeatures Power Supply 2.7V to 5.5V Low Supply Current < 0.3mA @ 3V 0.5V to 4.5V ratiometric output
Applications Solar Power HVAC/Refrigeration Heat Pumps Compressors Hydraulics
The BP series is designed to operate with low powerconsumption and ideal for battery usage. This series utilizesback-side piezo-resistive technology that is compatible withharsh medias.
TECHNICAL SPECIFICATIONS
Accuracy @ 25°C (linearity, repeatability, hysteresis, and calibration) ± 0.5% Span
Total Error Band ±1.0 %Span 0°C to 80°C ±1.5 %Span -20°C to 125°C
Pressure Ranges 0-15 PSI through 0-750 PSI (absolute or sealed gage)Operating Temperature Range -40°C to 125°CStorage Temperature Range -40°C to 150°CProof Pressure 3X rated pressure (Maximum 1500 psi)Burst Pressure 5X rated pressure (Maximum 2500 psi)Cycle Life >2 Million FS cyclesVibration 5g (33Hz)Drop (any axis) 1 mHousing Materials Brass, Aluminum, or stainless steel*Electrical Connection Packard, SwiftProtection IP67Media RefrigerantSealing Material Neoprene (Consult factory for other seal material options)
Approvals and Marks (UL Listed File E480159, Class III)
5
ELECTRICAL SPECIFICATIONS Min Typ Max Unit
Supply Voltage (Vsupply) 2.7 3 5.5 VDCSupply Current @ 3V - - 0.3 mAOutput Voltage (ratiometric 1) 10% to 90% typical, other ranges are available VsupplyUpper Clipping LevelLower Clipping Level
-5%
--
95%- Vsupply
Overvoltage Protection - - 5.5 VDCReversed Polarity Protection No -Short Circuit Protection (Vo to Vsupply, Vo to ground) - Yes -Output Load - 2 - KΩInsulation Resistance @ 500VDC for 1 minute 100 - - MΩDielectric Strength - 1800 for 1 sec - VACResponse Time - 25 - msIEC61000-4-2 ESD ±2KV Terminal / ±4KV Contact Discharge / ±8KV Air DischargeIEC61000-4-3 Radiated 10V/m (80-1000MHz)
IEC61000-4-4 Transient/Burst 1KVIEC61000-4-6 Conducted 3V
* Standard
6
Features Piezoresistive MEMS sensing Digital Trimming High Accuracy Wide Operating Temperature Range Refrigerant Media Compatibility Various connectors with color coded Long Life Rugged Design for outdoor use
Applications HVAC Commercial Refrigeration Heat Pumps Compressors Hydraulics
TECHNICAL SPECIFICATIONSAccuracy @ 25CLinearity, repeatability, hysteresis, and calibration
±0.5 %Span
Total Error Band ±1.0 %Span 0°C to 80°C ±1.5 %Span -20°C to 125°C ±2.0 %Span -40°C to 125°C
Pressure Ranges 0-100 through 0-750psi (absolute or sealed gage)Operating Temperature Range -40°C to 125°CStorage Temperature -40°C to 150°CProof Pressure 3X rated pressure (Maximum 1500 psi)Burst Pressure 5X rated pressure (Maximum 2500 psi)Cycle Life 10 Million + FS cyclesVibration 5g (33Hz)Drop (any axis) 1 mHousing Materials Stainless steel* or BrassElectrical Connection IP67Media RefrigerantSealing Material Neoprene (Consult Factory for other seal material options)
Approvals and Marks (UL Listed File E480159, Class III)
6
OUTPUT OPTIONS (See Electrical Specifications page 12 for details)
Ratiometric 0.5-4.5VDC (typical) *
Absolute Voltage 0-5VDC1-5VDC0-10VDC
Current Loop 4-20mA
* Standard
HP & LP Series
The HP and LP series are specially designed for use inHVAC/refrigeration applications, in the most demandingenvironments, where low cost is needed yet maintaininghigh accuracy, long term reliability, and long life. Theseseries are also very well suited for many other hydraulic andair compressor applications.
7
IP Series
Features Absolute or Sealed Gage Available in Brass or Stainless Steel Built-in Packard connector Various Outputs RoHS Compliant
Applications Vacuum Air Pressure
The IP Series pressure transducers utilize back-side piezoresistive technology and are suitable for vacuum and low to medium pressure applications.
TECHNICAL SPECIFICATIONSAccuracy @ 25°CLinearity, repeatability, hysteresis, and calibration
±0.5 %Span
Total Error Band ±1.0 %Span 0°C to 80°C ±1.5 %Span -20°C to 125°C ±2.0 %Span -40°C to 125°C
Pressure Ranges 0-15psi through 0-750psi (absolute, or sealed gage)
Operating Temperature Range -40°C to 125°C
Storage Temperature -40°C to 150°C
Proof Pressure 3X rated pressure (Maximum 1500 psi)
Burst Pressure 5X rated pressure (Maximum 2500 psi)
Cycle Life 10 Million + F.S cycles
Vibration 5g (33Hz)
Drop (any axis) 1 m
Housing Materials Brass or Stainless Steel *
Electrical Connection IP67
Media Non-corrosive gases Sealing Material Fluorosilicone (Consult Factory for other seal material options)
Approvals and Marks (UL Listed File E480159, Class III)
7
OUTPUT OPTIONS (See Electrical Specifications page 12 for details)
Ratiometric 0.5-4.5VDC (typical)*
Absolute Voltage 0-5VDC1-5VDC0-10VDC
Current Loop 4-20mA
* Standard
8
TP SeriesFeatures Accurate Real-Time Superheat Measurement Wide Temperature Range Simultaneous Pressure and Temperature In-flow Media Temperature Measurement
Applications HVAC Commercial Refrigeration Heat Pumps Compressors Hydraulics
The TP series provides pressure and temperature sensors in asingle robust and light package. The TP series is ideal for real-time accurate superheat measurement.
* Standard
TECHNICAL SPECIFICATIONS
Accuracy @ 25°C (linearity, repeatability, hysteresis, and calibration) ± 0.5% Span
Total Error Band±1.0 %Span 0°C to 80°C±1.5 %Span -20°C to 125°C
Pressure Ranges 0-15 PSI through 0-750PSI (absolute or sealed gage)Operating Temperature Range -40°C to 125°CStorage Temperature Range -40°C to 150°CProof Pressure 3X rated pressure (Maximum 1500 psi)Burst Pressure 5X rated pressure (Maximum 2500 psi)Cycle Life >1 Million FS cyclesVibration 5g (33Hz)Drop (any axis) 1 mHousing Materials Brass* or AluminumElectrical Connection Yazaki 4-pin, TE AMP-quadlokProtection IP67Media Refrigerant
Sealing Material Neoprene (Consult factory for other seal material options)
Approvals and Marks (UL Listed File E480159, Class III)
8
ELECTRICAL SPECIFICATIONS Min Typ Max Unit
Supply Voltage (Vsupply) 4.75 5 5.25 VDCSupply Current - 6 8 mAOutput Voltage (ratiometric 1) 10% to 90% typical, other ranges are available VsupplyUpper Clipping LevelLower Clipping Level
-5%
--
95%- Vsupply
Overvoltage Protection - - 16 VDCReversed Polarity Protection -16V - - VDCShort Circuit Protection - Yes -Output Load - 10 - KΩInsulation Resistance @ 500VDC for 1 minute 100 - - MΩDielectric Strength - 1800 for 1 sec - VACResponse Time - < 5 - msIEC61000-4-2 ESD ±2KV Terminal / ±8KV Contact Discharge / ±15KV Air DischargeIEC61000-4-3 Radiated 50V/m (80-1000MHz)IEC61000-4-4 Transient/Burst 1KVIEC61000-4-6 Conducted 3V
9
TP SeriesTEMPERATURE SPECIFICATIONS Min Typical Max UnitTemperature Sensor type NTC (negative temperature coefficient )Resistance at 25°C 10 KΩB-constant 25°C/50°C - 3380 - KB-constant 25°C/85°C (reference value) 3434 KB-constant 25°C/100°C (reference value) 3455 KResistance Value tolerance @25°C ± 1%B-constant (25C/50°C) tolerance ± 1%
Transfer Function
1𝑇𝑇𝑇𝑇 −
1𝑇𝑇𝑇𝑇𝑇𝑇𝑇𝑇 =
ln( 𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑇𝑇𝑇𝑇)𝐵𝐵𝐵𝐵
Where T and To is absolute temperature (°K)R= Resistance in ambient temperature T (°K)Ro = Resistance in ambient temperature To (°K)B= B-constant of thermistor°K=°C+273.15
050
100150200250
-50 -25 0 25 50 75 100 125 150
Resis
tanc
e (kΩ
)
Temperature ( °C)
Resistance vs. Temperture
Temp (°C) Rt(kΩ) Temp (°C) Rt(kΩ)
-40 195.652 45 4.917-35 148.171 50 4.161-30 113.347 55 3.535-25 87.559 60 3.014-20 68.237 65 2.586-15 53.65 70 2.228-10 42.506 75 1.925-5 33.892 80 1.6690 27.219 85 1.4525 22.021 90 1.268
10 17.926 95 1.1115 14.674 100 0.97420 12.081 105 0.85825 10 110 0.75830 8.315 115 0.67235 6.948 120 0.59640 5.834 125 0.531
9
10
VP SeriesFeatures Voltage outputs (0-5V, 1-5V, 0-10V) High Accuracy Wide Operating Temperature Range Compact Package with variety of thread ports and
electrical connections
Applications HVAC Commercial Refrigeration Heat Pumps Compressors Hydraulics
TECHNICAL SPECIFICATIONSAccuracy @ 25°CLinearity, repeatability, hysteresis, and calibration
±0.5 %Span
Total Error Band ±1.0 %Span 0°C to 80°C ±1.5 %Span -20°C to 125°C ±2.0 %Span -40°C to 125°C
Pressure Ranges 0-15 PSI through 0-750PSI (absolute or sealed gage)
Operating Temperatures -40°C to 125°C
Storage Temperature Range -40°C to 150°C
Proof Pressure 3X rated pressure (Maximum 1500psi)
Burst Pressure 5X rated pressure (Maximum 2500psi)
Cycle Life 10 Million + FS cycles
Vibration 5g (33Hz)Drop (any axis) 1 m
Housing Material Stainless Steel*, Brass
Electrical Connection IP67
Media Compatibility Refrigerants, oil, water and steam
Approvals and Marks (UL Listed File E480159, Class III)
10
The VP series is the standard high performance, high accuracy 0-5V/1-5V/0-10V pressure transducer that meets toughest industrial requirements
OUTPUT OPTIONS (See Electrical Specifications page 12 for details)
Absolute Voltage 0-5VDC1-5VDC0-10VDC *
* Standard
11
XP SeriesFeatures 4-20mA Current Loop Transmitter High Accuracy Wide Operating Temperature Range Compact package with variety of thread ports
and electrical connections.
Applications HVAC Commercial Refrigeration Heat Pumps Compressors Hydraulics
The XP series is the standard high performance, high accuracy 4-20mA current loop transmitter that meets toughest industrial requirements.
TECHNICAL SPECIFICATIONS
Accuracy @25°CLinearity, repeatability, hysteresis, and calibration
±0.5 %Span
Total Error Band ±1.0 %Span 0°C to 80°C ±1.5 %Span -20°C to 125°C ±2.0 %Span -40°C to 125°C
Pressure Ranges 0-15 PSI through 0-750PSI (absolute or sealed gage)
Operating Temperatures -40°C to 125°C
Storage Temperature Range -40°C to 150°C
Proof Pressure 3X rated pressure (Maximum 1500 psi)
Burst Pressure 5X rated pressure (Maximum 2500psi)
Cycle Life 10 Million + FS cycles
Vibration 5g (33Hz)
Drop (any axis) 1 m
Housing Materials Stainless Steel*, Brass
Electrical Connection IP67
Media Compatibility Refrigerants, oil, water and steam
Approvals and Marks (UL Listed File E480159, Class III)
11
OUTPUT OPTIONS (See Electrical Specifications page 12 for details)
Current Loop 4-20mA
* Standard
12
Electrical Specifications
1
Electrical Specifications Min Typ Max UnitSupply Voltage 9 24 33 VDCSupply Current 24 mAOutput 4 to 20 mAOvervoltage Protection +33 VDCReversed Polarity Protection -33 VDCShort Circuit Protection YesOutput Load 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉 − 9𝑉𝑉𝑉𝑉
20𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚Ω
Insulation Resistance @ 500VDC for 1 minute 100 MΩElectrical Housing Isolation 1800 for 1 sec VACResponse Time 10 mSIEC61000-4-2 ESD ±2KV Terminal / ±8KV Contact Discharge / ±15KV Air DischargeIEC61000-4-3 Radiated 50V/m (80-1000MHz)IEC61000-4-4 Transient/Burst 1KVIEC61000-4-6 Conducted 3V
Electrical Specifications Min Typ Max UnitSupply Voltage (Vsupply) 4.75 5 5.25 VDCSupply Current - 6 8 mAOutput Voltage 10% to 90% typical, other ranges are available VsupplyUpper Clipping LevelLower Clipping Level
-5%
--
95%- Vsupply
Overvoltage Protection - - 16 VDCReversed Polarity Protection -16V - - VDCShort Circuit Protection - Yes -Output Load - 10 - KΩInsulation Resistance @ 500VDC for 1 minute 100 - - MΩDielectric Strength - 1800 for 1 sec - VACResponse Time - < 5 - msIEC61000-4-2 ESD ±2KV Terminal / ±8KV Contact Discharge / ±15KV Air DischargeIEC61000-4-3 Radiated 50V/m (80-1000MHz)IEC61000-4-4 Transient/Burst 1KVIEC61000-4-6 Conducted 3V
Electrical Specifications Min Typ Max UnitSupply Voltage: output (0-5 VDC & 1-5 VDC) 9 24 33 VDCSupply Voltage: output (0-10 VDC) 12 24 33 VDCSupply Current 24 mAOutput 0-5 / 1-5 / 0-10 VDCOvervoltage Protection 33 VDCReversed Polarity Protection -33 VDCOutput Load ≥10 KΩInsulation Resistance @ 500VDC for 1 minute 100 MΩElectrical Housing Isolation 1800 for 1 sec VACResponse Time 10 mSIEC61000-4-2 ESD ±2KV Terminal / ±8KV Contact Discharge / ±15KV Air Discharge
IEC61000-4-3 Radiated 50V/m (80-1000MHz)
IEC61000-4-4 Transient/Burst 1KVIEC61000-4-6 Conducted 3V
ABSOLUTE VOLTAGE OUTPUT: VP SERIES and Option on HP & LP/AP/IP SERIES
CURRENT LOOP 4-20mA: XP SERIES and Option on HP & LP/AP/IP SERIES
RATIOMETRIC (Output is proportional to Voltage supply): AP/HP & LP/IP SERIES
13
Current Loop 4-20mA: Output Characteristic Graph and typical application schematic
Absolute Voltage: Output Characteristic Graph and typical application schematic
Application Schematic
13
10.0
0.0
Zero Full Scale
OUTPUT (VDC)
PRESSURE
Normal Operating Range
20.0
4.0
Zero Full Scale
OUTPUT (mA)
PRESSURE
Normal Operating Range
Ratiometric: Output Characteristic Graph and typical application schematic
95% Vdd (Ceiling Clamp)
90% Vdd
10% Vdd
5% Vdd (Floor Clamp)
4.75
4.50
0.50
0.25
Zero Full Scale
OUTPUT (VDC)
PRESSURE
Normal Operating Range
Vdd
Vo
Ground
R Loa
d Process Monitor/
Controller
PRESSURETRANSDUCER(Ratiometric)
5V
+
-
Vdd
Vo
Ground
R Loa
d Process Monitor/
Controller
PRESSURETRANSDUCER
(0-10V)
24V
+
-
+
-
4-20mA
Process Monitor/Controller
PRESSURETRANSMITTER
(4-20mA)
RLoad
24V
14
Electrical ConnectorsConnector Type Code Picture
Potable connector 1-Black*2-Blue
Yazaki Connector
3 – Black*4 – Blue
Packard Metric 5- Black *6- Blue7- Red8- YellowG- Green
Shielded Boot Cable 9- 2m*A- 1m
Swift B-Black*C-BlueD-red
4-pin Yazaki Connector (TP series only) E- Black
4-pin AMP MQSTM connector(TP Series only) F- Black
14* Standard
15
TP Series only
15
YAZAKI 4-PIN CONNECTOR
4-pin AMP MQSTM CONNECTORNPT1/8-27 NPT1/4-18
M12x1.257/16-20 UNF Male
NPT1/8-27 NPT1/4-18
M12x1.257/16-20 UNF Male
Pin Out
Pin Out
16
Connector Pin Out
16
Vsupply
Vout
Ground Vsupply +Vsupply -
N/CPACKARD CONNECTOR PACKARD CONNECTOR
YAZAKI 3-PIN CONNECTOR YAZAKI 3-PIN CONNECTOR
POTABLE CONNECTOR POTABLE CONNECTOR
SWIFT CONNECTOR SWIFT CONNECTOR
SHIELDED BOOT CABLE SHIELDED BOOT CABLE
Ratiometric, 0-5V, 1-5V, 0-10V 4-20mA
Vsupply
Vout
Ground
N/C
Vsupply
Vout
Ground
N/C
Vo
Ground
Vsupply
Vsupply(Red)
Vo (White)
Ground(Black)
Vsupply+ Vsupply-
N/C
N/C
Vsupply+ Vsupply-
N/C
N/C
Vsupply+(Red)
Vsupply- (Black)
N/C
Vsupply + Vsupply -
17
Part Number Ordering
O-Ring Materials
* The compatible refrigerants are based on recommendation from Various o-ring manufacturers
Thread Selection Table Thread AvailabilityThreadCode
Thread TP HP AP IP BP XP VP
1 7/16-20 UNF Female, 1/4SAE, Schrader Hex-Body • • • •2 7/16-20 UNF Female, Schrader • • • •3 7/16-20 UNF Male, 1/4SAE Flare • • • • • •4 7/16-20 UNF Male • • • • • • •5 3/8-24 UNF-2A Male • • • • •6 1/2-20 UNF-2A Male, Flare • • • • • •7 1/4OD Copper tube, 3mm tip • • • •8 1/4OD Copper tube, 7mm tip • • • •
10 G1/4 Male • • • • • •11 NPT 1/8-27 Male • • • • • • •12 NPTF 1/8-27 Male (F: Fuel) • • • • • •13 NPT 1/4-18 Male • • • • • • •14 G3/8 Male • • • • • •15 M12x1.25 Male • • • • • • •16 M16x1.5 Ermeto Male • • • • • •17 7/16-20 UNF Female, 1/4SAE, Schrader Hex-Port • • • •
Material Compatible with
NeopreneRefrigerants, Ammonia, carbon dioxide, Propane, ButaneR22, R134A, 404A,407A,407C,407F,410A,417A,422A,422D,427A,438A,448A,449A,450A,507A,513A *
Viton Engine Oil, Transmission Oil, Hydraulic Oil
Fluorosilicone Fuels, Mineral oils
HNBR HFA, HFB, HFC hydraulic oils
Buna-N Petroleum oil, mineral oil and grease, propane, butane, diesel fuel
Product Series
1
H V P 0750 S 01 - S 1 5
Output Type
2
Pressure Unit
3
Pressure Range
4-7
Pressure Type
8
Port Threat 9-10
Always dash
11
Housing Material
12
O-ring Material
13
Electrical Connector
14
A- AP (Automotive)H- HP (HVAC)I - IP (Industrial)
B- BP (Battery Power)T- TP (Pressure & Temp)
V- VP (Absolute Voltage)
X— XP (4-20mA)
V- RatiometricF- 0-5VG- 1-5VH- 0-10VI- 4-20mA (XP Series)
P- PSIB- BarK- kPaM- MPa
A- AbsoluteS- Sealed Gage
1 - Neoprene2 - viton3 - Flurosilicone4 - HNBR5 - Buna-N
1- Potable connector black2- Potable connector blue3- Yazaki connector black4- Yazaki connector blue5- Packard black6- Packard blue7- Packard red8- Packard yellowG- Packard GreenJ- Packard White9- Boot cable 1mA- Boot cable 2mH- Boot cable 5mB- Swift blackC- Swift blueD- Swift redE- Yazaki 4 pin blackF- AMP Quadlok 4-pin blackK- M12 Black
01- 7/16 - 20 UNF Female, 1/4 SAE, Shrader Hex-Body02- 7/16 - 20 UNF Female, Shrader03- 7/16 - 20 UNF Male, 1/4 SAE Flare04- 7/16 - 20 UNF Male05- 3/8 - 24 UNF Male06- 1/2 - 20 UNF Male, 1/4 SAE07- 1/4 OD Copper tube, 3mm tip08- 1/4 OD Copper tube, 7mm tip10- G1/4 Male11- NPT 1/8-27 Male12- NPTF 1/8-27 Male13- NPT 1/4-18 Male14- G 3/8 Male15- M12x1.25 Male16- M16x1.5 Male17- 7/16-20 UNF Female, 1/4 SAE, Shrader Hex-Port
A- AluminumB- BrassS- Stainless Steel
PSI/kPa: XXXXBar: XX.X
MPa: X.XX
V, F, G,H, I
V
F, G, H
I
Consult factory for other options
18
NPT 1/8-27 Male, HEX24
18
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
19
NPT 1/4-18 Male, HEX24
19
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
20
7/16-20 UNF Female, 1/4SAE, Shrader, HEX24
20
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
21
7/16-20 UNF Male, 1/4SAE Flare, HEX24
21
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
22
1/4OD Copper Tube
22
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mAPackard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
23
G1/4 Male, HEX24
23
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
24
1/2-20 UNF Male, 1/4SAE, HEX24
24
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
25
M16x1.5 Male, HEX24
25
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
26
G3/8 Male, HEX24
26
Ratiometric
0-5V, 1-5V, 0-10V, 4-20mA
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
Packard Connector Yazaki Connector
Potable ConnectorSwift Connector
Shielded Boot Cable
272727
282828
29
CP10 SeriesFeaturesPiezoresistive MEMS SensingDual-in-Line PackageCurrent ExcitationAbsolute, Gage, Differential0°C to 80°C CompensatedHigh SensitivityHigh Accuracy
ApplicationsMedical InstrumentsAir Flow MeasurementFactory AutomationProcess Control
The CP10 series is temperature compensated, piezoresistive silicon pressure sensor in a dual-in-line package. It is designed for cost sensitive applications that requires high performance and long-term stability over a wide temperature range. A gain set resistor is included to normalize the FSO.
Current Excitation Ceramic Sensors
TECHNICAL SPECIFICATIONSPressure Ranges Gage and Differential
5psi, 15psi, 30psi, 50psi, 100psi
Absolute15psi, 30psi, 50psi, 100psi
For other pressure range, please contact DunAn Sensing.Operating Temperature Range -40°C to 125°CCompensated -00°C to 80°CStorage -50°C to 150°CMax Pressure 6 3XMedia Compatibility7 Compatible with Exposed MaterialsPositive differential and gauge ports Dry Gases onlyAbsolute, Negative differential ports Dry Gases only
Approvals and Marks
ELECTRICAL SPECIFICATIONS Min Typical Max UnitFS Output (FSO) 2,3 75 100 125 mVZero Pressure Output 3 -2 - 2 mVLinearity 4,8 -0.1 -Pressure Hysteresis -0.1 - 0.1 %FSOInput Impedance 2,500 4,000 6,000 ΩOutput Impedance 4,000 5,000 6,000 ΩThermal Span Accuracy 3,5,8 -0.5 - 0.5 %FSOThermal Zero Accuracy 3,5,8 -0.5 - 0.5 %FSOTemperature Coefficient- Resistance 5 - 0.2 - %/°CThermal Zero Hysteresis 5 - 0.1 - %FSOInput Excitation - 1.5 2.0 mA
1. Ambient temperature (25°C).2. Output span of unamplified sensor using the gain set
resistor and the circuit shown in the schematic drawing.3. Compensation resistors are included in the sensor
package; no additional external resistor required.4. Best fit straight line.5. Temperature range 0°C to 80°C reference to 25°C.
6. 3X or 200psi maximum, whichever is less.7. Exposed material are pyrex, ceramic, silicon, epoxy, RTV, and
stainless steel.8. 5psi (0.34KPa) specifications:
o Linearity: ± 0.25 %FSOo TC-Span: ± 0.75 %FSOo TC-Zero: ± 0.75 %FSO
29
30
MECHANICAL DIMENSIONS inch (mm) ELECTRICAL CONNECTIONS
Package Diagram Schematic Diagram
CP10 Series Current Excitation Ceramic Sensors
0.6 in (15.24mm)
0.58 in(14.73mm)
0.32 in(8.13mm)
0.37 in (9.4mm)
0.2 in(5.1mm)
0.10 in (2.54mm)
8 X 0.34 in(8.64mm)
0.16 in(4.06mm)
8 X 0.02 in(0.51mm)
0.49 in(12.44mm)
0.125 in(3.18mm)
0.55 in (14mm)
CERAMIC SUBSTRATE
CERAMIC COVER
TUBE
0.37 in(9.4mm)
0.01 in(0.25mm)
1 2 3 4
8 7 6 5
0.12 in(3.05mm)
1. All dimensions are for reference only.2. Lead Pins can be either in the same or the opposite of the tube.
Not use for Gauge
Used for positive differential
Not use for absolute
+
-
+
-
Out-
Out+
Sup+
Sup-
GainSet
1
100kΩ
100kΩ
A1
A2
GROUND
OUT+
OUT-
3.012VAmplified FSO
5
6
3
287
4
NC NC
PRESSURE SENSOR
I
Lead Connection1 Out (-)2 Supply (-)3 Out (+)4 Supply (+)5 Gain Set Resistor (+)6 Gain set Resistor (-)7 N/C8 N/C
30
PART NUMBER FOR ORDERING
CP10- 015 A U L
Pressure Range(psi)
005015030050100
Pressure Type
A= AbsoluteD= DifferentialG= Gauge
Lead Configuration
U = UpD = Down
Tube Options
L= LongS = ShortN = None
31
CP20 SeriesFeatures Piezoresistive MEMS Sensing Dual-in-Line Package Voltage Excitation Absolute, Gage, Differential 0°C to 80°C Compensated High Sensitivity High Accuracy
Applications Medical Instruments Air Flow Measurement Factory Automation Process Control
Voltage Excitation Ceramic Sensors
1. Ambient temperature (25°C).2. Output span of unamplified sensor using the
current set resistor and the circuit shown in the schematic drawing.
3. Compensation resistors are included in the sensor package; no additional external resistor required.
4. Best fit straight line.5. Temperature range 0°C to 80°C reference to
25°C.
6. 3X or 200psi maximum, whichever is less.7. Exposed material are pyrex, ceramic, silicon, epoxy, RTV,
and stainless steel.8. 5psi (0.34KPa) specifications:
o Linearity: ± 0.25 %FSOo TC-Span: ± 0.75 %FSOo TC-Zero: ± 0.75 %FSO
The CP20 series is temperature compensated, piezoresistive silicon pressure sensor in a dual-in-line package. It is designed for cost sensitive applications that requires high performance and long-term stability over a wide temperature range. A gain set resistor is included to normalize the FSO.
TECHNICAL SPECIFICATIONSPressure Ranges Gage and Differential
5psi, 15psi, 30psi, 50psi, 100psi
Absolute15psi, 30psi, 50psi, 100psi
For other pressure range, please contact DunAn Sensing.Operating Temperature Range -40°C to 125°CCompensated -00°C to 80°CStorage -50°C to 150°CMax Pressure 6 3XMedia Compatibility7 Compatible with Exposed MaterialsPositive differential and gauge ports Dry Gases onlyAbsolute, Negative differential ports Dry Gases only
Approvals and Marks
ELECTRICAL SPECIFICATIONS Min Typical Max UnitFS Output (FSO) 2,3 49.5 50 50.5 mVZero Pressure Output 3 -2 - 2 mVLinearity 4,8 -0.1 -Pressure Hysteresis -0.1 - 0.1 %FSOInput Impedance 2,500 4,000 6,000 ΩOutput Impedance 4,000 5,000 6,000 ΩThermal Span Accuracy 3,5,8 -0.5 - 0.5 %FSOThermal Zero Accuracy 3,5,8 -0.5 - 0.5 %FSOTemperature Coefficient- Resistance 5 - 0.2 - %/°CThermal Zero Hysteresis 5 - 0.1 - %FSO
31
3232
PART NUMBER FOR ORDERING
CP20- 015 A U L
Pressure Range(psi)
005015030050100
Pressure Type
A= AbsoluteD= DifferentialG= Gauge
Lead Configuration
U = UpD = Down
Tube Options
L= LongS = ShortN = None
MECHANICAL DIMENSIONS inch (mm) ELECTRICAL CONNECTIONS
Package Diagram Schematic Diagram
Lead Connection1 Out (-)2 Supply (-)3 Out (+)4 Supply (+)5 Current Set Resistor (+)6 Current set Resistor (-)7 N/C8 N/C
Out-
Out+
Sup+
Sup-
Current Set
GROUND
OUT+
OUT-
+
-A1
Vref Vout (FSO) = 50mV
287 6 5
3
1
NC NC
4
PRESSURE SENSOR
0.6 in (15.24mm)
0.58 in(14.73mm)
0.32 in(8.13mm)
0.37 in (9.4mm)
0.2 in(5.1mm)
0.10 in (2.54mm)
8 X 0.34 in(8.64mm)
0.16 in(4.06mm)
8 X 0.02 in(0.51mm)
0.49 in(12.44mm)
0.125 in(3.18mm)
0.55 in (14mm)
CERAMIC SUBSTRATE
CERAMIC COVER
TUBE
0.37 in(9.4mm)
0.01 in(0.25mm)
1 2 3 4
8 7 6 5
0.12 in(3.05mm)
1. All dimensions are for reference only.2. Lead Pins can be either in the same or the opposite of the tube.
Not use for Gauge
Used for positive differential
Not use for absolute
CP20 Series Voltage Excitation Ceramic Sensors
33
CP30 SeriesFeatures Piezoresistive MEMS Sensing Dual-in-Line Package Absolute, Gage, Differential 0°C to 80°C Compensated High Sensitivity High Accuracy
Applications Medical Instruments Air Flow Measurement Factory Automation Process Control
The CP30 series are temperature compensated transducers packaged in a dual-in-line configuration. The CP30 series is designed for use with non-corrosive, non-ionic media such as air or dry gases. It offers various output options (analog or digital) with high performance and long-term stability.
Low to Medium Pressure Ceramic Transducer
TECHNICAL SPECIFICATIONSLinearity, repeatability, hysteresis, and calibrationPressure Accuracy (Total Error Band)
±0.5 %Span 25°C ±1.0 %Span -20°C to 85°C
Temperature Output Accuracy (digital version only) ±3°C over Operating Temperature RangePressure Ranges Absolute: 0-5psi to 0-100psi
Gage: 0-5psi to 0-100psiCompensated Temperature Range -20°C to 85°COperating Temperature Range -40°C to 85°CStorage Temperature -40°C to 100°CProof Pressure 2X rated pressure rangeBurst Pressure 3X rated pressure range or 200 PSI max
Approvals and Marks
ANALOG ELECTRICAL SPECIFICATIONS Min Typical Max UnitSupply Voltage (Vsupply) 1
3.3 VDC5.0 VDC
3.04.75
3.35
3.55.25
VDC
Supply Current3.3 VDC5.0 VDC
--
--
3.04.0
mA
Output Voltage 10% to 90% (other options available) VsupplyStartup time ( power up to data ready) - - 5 msClipping limitUpperLower
-5%
--
95%-
% Vsupply
DIGITAL ELECTRICAL SPECIFICATIONS Min Typical Max UnitSupply Voltage (Vsupply) 1
3.3 VDC5.0 VDC
3.04.75
3.35
3.55.25
VDC
Supply Current3.3 VDC5.0 VDC
--
--
4.04.5
mA
Startup Time (power up to data ready) - - 5 msPressure Output Resolution - 14 bitsSPI & I2C Voltage Level - Low - - 20% VsupplySPI & I2C Voltage Level - High 80% - - VsupplySDA/MISO, SCL/SCLK, SS pull-up resistor - 2 - kΩTemperature Output Resolution 2 - 11 - bits
1 The sensor is not reverse polarity protected. In correct application of supply voltage or ground to the wrong pin may cause electric failure.
33
34
CP30 Series Low to Medium Pressure Ceramic Transducer
1 The sensor is not reverse polarity protected. In correct application of supply voltage or ground to the wrong pin may cause electric failure.
DIGITAL ELECTRICAL SPECIFICATIONS Min Typ Max UnitSupply Voltage (Vsupply) 1
3.3 VDC5.0 VDC
3.04.75
3.35
3.55.25
VDC
Supply Current3.3 VDC5.0 VDC
--
--
4.04.5
mA
Startup Time (power up to data ready) - - 5 msPressure Output Resolution - 14 bitsI2C Voltage Level – Low - - 20% VsupplyI2C Voltage Level - High 80% - - VsupplySDA, SCL pull-up resistor - 2 - kΩ
1 The sensor is not reverse polarity protected. In correct application of supply voltage or ground to the wrong pin may cause electric failure.
MECHANICAL DIMENSIONS (mm)
Note: All dimensions are for reference only.
ELECTRICAL CONNECTIONS
Pin 1 2 3 4 5 6 7 8ANALOG N/C Vsupply Vout Gnd N/C N/C N/C N/C
SPI Gnd Vsupply MISO SCLK SS N/C N/C N/CI2C Gnd Vsupply SDA SCL N/C N/C N/C N/C
Recommended PCB layout
8
7
6
5
1
2
3
4
10.16
7.62
2.54
34
050100150
V - Analog 005 A - Absolute015 G - Gage030
D - Digital
CP30- D 100 A
Output Pressure Range (psi) Pressure Type
PART NUMBER FOR ORDERING
35
CP40 SeriesFeatures Piezoresistive MEMS Sensing Dual-in-Line Package Absolute or Gage 0°C to 80°C Compensated High Sensitivity High Accuracy
Applications Medical Instruments Air Flow Measurement Factory Automation Process Control
The CP40 series are temperature compensated transducers packaged in a dual-in-line configuration. The CP40 series is designed for use with non-corrosive, non-ionic media such as air or dry gases. It offers various output options (analog or digital) with high performance and long-term stability.
Ultralow Pressure Ceramic Transducer
1 The sensor is not reverse polarity protected. In correct application of supply voltage or ground to the wrong pin may cause electric failure.
TECHNICAL SPECIFICATIONSPressure Accuracy (Total Error Band)Linearity, repeatability, hysteresis, and calibration
±1.5 %Span 0°C to 50°C ±2.0 %Span -20°C to 85°C
Temperature Output Accuracy (digital version only) ±3°C over operating temperature rangePressure Range Gage: 0-1 inch H2O through 0-20 inch H2OCompensated Temperature Range 0°C to 50°COperating Temperature Range -20°C to 80°CStorage Temperature -40°C to 100°CProof Pressure 0-1inch to 0-4 inch H2O: 10X, 0-10inch to 0-20 inch H2O: 5XBurst Pressure 0-1inch to 0-4 inch H2O: 20X, 0-10inch to 0-20 inch H2O: 10XCycle Life 1million pressure cycles minimumVibration 5g (33Hz)Humidity 0% to 95%RH, non-condensingSubstrate Material Alumina CeramicAdhesives Epoxy, siliconePorts and covers High temperature polyamidePackage Type DIPMedia Compatibility Dry Gases onlySoldering Time and Temperature Lead solder : 250°C 5 sec. max, Reflow (SMT) at 250°C for 15 sec. maxESD (Human Body Model) ± 2KV
ANALOG ELECTRICAL SPECIFICATIONS Min Typ Max UnitSupply Voltage (Vsupply) 1
3.3 VDC5.0 VDC
3.04.75
3.35
3.55.25
VDC
Supply Current3.3 VDC5.0 VDC
--
--
3.04.0
mA
Output Voltage 10% to 90% (other options available) VsupplyStartup time (power up to data ready) - - 5 msClipping limitUpperLower
-5%
--
95%-
% Vsupply
35
36
CP40 Series Ultralow Pressure Ceramic SensorsDIGITAL ELECTRICAL SPECIFICATIONS Min Typ Max UnitSupply Voltage (Vsupply) 1
3.3 VDC5.0 VDC
3.04.75
3.35
3.55.25
VDC
Supply Current3.3 VDC5.0 VDC
--
--
4.04.5
mA
Startup Time (power up to data ready) - - 5 ms
Pressure Output Resolution - 14 bitsI2C Voltage Level – Low - - 20% VsupplyI2C Voltage Level - High 80% - - VsupplySDA, SCL pull-up resistor - 2 - kΩ
1 The sensor is not reverse polarity protected. In correct application of supply voltage or ground to the wrong pin may cause electric failure.
MECHANICAL DIMENSIONS (mm)
Note:1) All dimensions are for reference only.
ELECTRICAL CONNECTIONS
Pin 1 2 3 4 5 6 7 8ANALOG N/C Vsupply Vout Gnd N/C N/C N/C N/C
SPI Gnd Vsupply MISO SCLK SS N/C N/C N/CI2C Gnd Vsupply SDA SCL N/C N/C N/C N/C
Recommended PCB layout
8
7
6
5
1
2
3
4
10.16
7.62
2.54
36
20: 0 - 20" H2O
V - Analog 01: 0 - 1" H2O A - Absolute
02: 0 - 4" H2O G - Gage
10: 0 - 10" H2O
D - Digital
CP40- D 20 G
Output Pressure Range (psi) Pressure Type
PART NUMBER FOR ORDERING
3737
MKT00010 Rev. A, 2017
DunAn Sensing LLC – USA
1953 Concourse DriveSan Jose, California 95131
Phone: (408) 613-1015Fax: (408) 503-6308
DunAn Sensing reserves the right to make changes to any product in this publication without notice. The information we supply is believed to beaccurate and reliable as of this printing. All operating parameters must be validated for each customer application by customer’s technicalexperts.DunAn Sensing assumes no responsibility for customers’ product designs nor any liability arising out of the application or use of any product.DunAn Sensing disclaims any and all liability, including without limitation consequential or incidental damages.
Copyright 2017 © DunAn Sensing, LLC. All rights reserved