20
Presented by: Stephen K. Storm Storm Technologies, Inc. (USA) Track 4: Operating & Servicing Plants Session: Performance Management & Optimization Date: Wednesday 7 th October 2009

Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Presented by: Stephen K. Storm

Storm Technologies, Inc. (USA)

Track 4: Operating & Servicing Plants

Session: Performance Management & Optimization

Date: Wednesday 7th October 2009

Page 2: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

1. Stephen K. Storm

Executive Vice President, Storm Technologies, Inc.

2. Scott M. Smouse

Senior International Manager , U.S. Department of Energy,

National Energy Technology Laboratory

3. Babatunde O. Fapohunda, CEng, MIET

Senior Energy Analyst, Science Applications International Corporation

4. Radha P. Krishnan, Ph.D.

International Program Specialist, Science Applications International Corporation

5. Jacob Stover

Combustion Specialist, Storm Technologies, Inc.

Authors

Page 3: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Objectives

A three-phase combustion optimization and efficiency improvement

training program started in 2008 and continues throughout 2009

Classroom training in India for participating

utilities engineers

- Training and demonstration of

best practices and testing techniques for

participating utilities engineers in U.S. power

plants

- Demonstration of testing &

evaluation of efficiency at the selected power

Plants

Plant Selection (2008 - 2009)

Two (2) state utilities selected to participate initially

One (1) 210-MW unit from each state utility plant selected

Work with the third utility is in progress in Southern India

Page 4: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Program Development – Phase I

1) Fuel Line Clean Airflow Testing

a) Balance and distribution evaluation

b) Minimum airflow set-point evaluations

2) Primary Airflow Measurements and Calibration Tests

a) Evaluation of the transport airflow to the mills, air/fuel ratios and

the heat balance for each milling system.

3) Dirty Airflow and Isokinetic Coal Sampling via the STORM Method

a) Fuel line distribution, balance and air-fuel ratios

b) Representative coal fineness for each fuel pipe

4) Secondary Airflow Measurements and Calibration Tests

a) Evaluation of total combustion airflow to the unit

5) Furnace Exit HVT Traverses

a) Determination of actual flue gas oxygen, temperature, and carbon

monoxide profiles

b) Comparison of actual furnace exit gas temperature vs.

temperature gun

6) Air In-Leakage Survey (4 Major Regions)

a) Furnace exit

b) Economizer outlet

i. Comparison of actual boiler oxygen vs. control indicated

c) Air heater outlet

d) ID fan discharge

Page 5: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Test Program Protocol Cont’d

7) Flue Gas Flow Measurement

8) Boiler Efficiency & Heat Rate Evaluation

9) Fly Ash Particle Size and Bottom Ash LOI Analyses

10) Tuning and Optimization

11) Fly-Ash and Bottom-Ash LOI Results

12) Radiant Losses/Survey with Temperature Gun

13) Control Indications Evaluation

14) Analytical Evaluation

Page 6: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Phase II - U.S. Training

Representatives from the state utilities plants visited the United States power

plants to learn through demonstration of combustion optimization testing

techniques and observe first-hand best practices

Training sites include:

Reid Gardner Power Station (Nevada)

Orlando Utilities, Stanton Energy Center

E.ON – U.S.’s Trimble County Station

Orlando Utilities Commission’s Stanton Energy

Center was the site used for demonstration of

performance testing techniques

Page 7: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

210-MW Associated Babcock Limited (ABL) front-fired boiler with

tubular air heaters and six 8.5E-9 mills

Plant A Phase III

Page 8: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Tangentially-fired boiler Supplied by

Bharat Heavy Electricals Limited

(BHEL), with regenerative air

heaters and XRP mills

Plant B Phase III

Page 9: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Efficiency & Fuel Conservation Heat Rate & GTCHR (Steam Cycle) Challenges

System efficiency related issues are impacting coal consumption, efficiency

& CO2 production

Reduced Generation

Coal Supply

Supply Shortage

Variations in Fuel Quality (2,500kcal – 4,000kcal/kg)

increased levels of CO2 emissions attributable to coal blending & deviations

from design specification. Despite stable carbon content, fuel consumption

is nearly twice the design values

unnecessary supplemental fuel consumption impacting heat rate

Challenges Identified

Page 10: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

High primary

airflows contribute

to unnecessarily

high dry gas

losses. Also poor

fuel distribution,

poor coal fineness

& load Control

High furnace exit gas temperatures contribute to overheated metals, high de-superheating spray

flows, excessive soot blower operation

Coal dribble/spillage due to

throats that are too large

Fly ash Carbon losses

Bottom ash carbon content; Bottom

Ash Hopper - Air In-leakage

Reduced Lower

Furnace Heat

Absorption

Increased Mass flow through the

precipitator decreases precipitator

performance

Air In-Leakage

Typical Thermal Plant Performance Opportunities

ID Fan Capacity

Limitations

(due to high air in-leakage)

Coal Fineness

Page 11: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Evaluations Performed

• Gross Turbine Cycle Heat Rate (GTCHR)

• Fuel Line Performance Measurements

• Mill Inlet Primary Airflow Calibrations

• Total Secondary Airflow Measurement & Calibration

• Furnace Exit Gas Temperature & Flue Gas Constituents

• Economizer Outlet Flue Gas Measurements

• Fly ash & Bottom Ash ~ UBC Measurements

• ID Fan Discharge / Stack Inlet Flue Gas Measurements

• “Stealth Loss” Evaluation

Page 12: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Performance Testing & Input Optimization

HVT Testing Location

Secondary Air Testing Location

Fuel Line Sampling Locations

Primary Air Testing Location

Economizer Outlet Testing Location

APH Outlet Testing Location

ID Fan Discharge Testing Location

Page 13: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Six Basic Steps of the APPLES* Program

Program Introduction

and/or Performance Preservation Planning

Training & Implementation of a Performance Testing

Program

Evaluation of the Plants Data & Test Results

(Data Interpretation)

Review of Plant Performance Opportunities

& Outage Planning

Post Outage Testing and Tuning

Post Outage Testing Presentation and

Overview

* Annual Plant Performance Evaluation Services

Page 14: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Pre-Testing Documented Improvements

73%14%

13%

Reduction in Dry Gas Losses

Reduced UBC (LOI)

Reduced AUX Power

Recommendations

implemented during the

outages resulted in heat

rate improvement of

75kcal/kWh(293btu/kWh)

on the average

Air In-Leakage

ID Fan Aux Fan HP

Flyash LOI

Page 15: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Impact of Controllable Losses on Plant Efficiency

With average plant thermal

efficiency measured at

between 30 and 31%, this

yields hundreds of kcals

approximately (~1,000 – 2,000

Btu’s) of heat rate

improvement that were found

available for improvement.

20%

2%7%

53%

18%

Outage Improvements (Completed)

Aux. ID Fan HP Opportunities

LOI and Rejects

Turbine Opportunities

Boiler Opportunities

Page 16: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Average CO2 Emissions Impact (“As Fired” Versus Design)

Average CO2 Emissions

Boiler Opportunities

Turbine Opportunities

Outage Improvements (Completed)

Aux. Horse Power Savings (ID Fan)

124,000 tonnes of CO2 on

the average could be

reduced if both plants

could operate closer to

their design values.

Assuming opportunity for

improvement in all 6 units

at each plant is the same,

~744,000 tonnes CO2/year

is potentially achievable

at each plant.

Page 17: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Impacts of Performance on Fuel Cost

Increased Fuel Cost (Average from each unit)

Outage Improvements (Completed)

Boiler Opportunities

Turbine Opportunities

Aux. ID Fan HP Opportunities

Page 18: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

1 Crores = 200,000 U.S.D.

Parameter Value

Load 210MW (Gross)

Operation 7,000 Hrs.

Fuel GCV 3,000kcal/kg

Coal Cost 2,500 Rs./Ton

Ash

Content 50%

Heat Rate Impact on Fuel Cost Only (Average)

61,000,000

62,000,000

63,000,000

64,000,000

65,000,000

66,000,000

67,000,000

68,000,000

300.0

305.0

310.0

315.0

320.0

325.0

330.0

335.0

340.0

345.0

2,5

20

2,5

45

2,5

70

2,5

95

2,6

20

2,6

45

2,6

70

2,6

95

2,7

20

2,7

45

2,7

70

Ye

arly F

ue

l C

ost (U

.S.D

.)

Ye

arly F

ue

l C

ost (C

rore

s)

Heat Rate (Kcal/KWhr)

2500 RS/ton

$

$

$

$

$

$

$

$

+$5 Million USD

Page 19: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Twelve Key Points

1. Team training and commitment is essential

2. Installation of the testing ports and a performance program is essential

3. Excess O2 at the furnace exit and economizer outlet must be optimized

4. Pulverized coal fineness must be optimized

5. Balance and supply adequate secondary air flow. This must be controlled with

validated and proven total airflow metering devices within each of the main

supply ducts.

6. Wind box to furnace differential must be optimum

7. Mill air to fuel ratios should be optimum and controlled

8. Fuel flow should be balanced to ±10% of the mean

9. Clean air velocities (fuel line transport energy) balanced within ±2%

10. Burner tolerances within ±¼ inch (6 mm)

11. Boiler efficiency and air in-leakage assessments are essential

12. Air in-leakage must be maintained at a minimum

Page 20: Presented by: Stephen K. Storm Storm Technologies, Inc ... · Program Development –Phase I 1) Fuel Line Clean Airflow Testing a) Balance and distribution evaluation b) Minimum airflow

Closing

o The results achieved have identified what is needed to improve the efficiency

opportunities as well as improve the plants capacity and emission levels.

o These plants immediately began utilizing the protocol for plant wide

improvements and trouble shooting efforts.

o Replicating efficiency improvement practices in all 6 units at each plant and

realizing the full combustion optimization potential, substantial overall

reduction of CO2 emissions could be realized

o In addition to efficiency improvements achieved both plants, the testing

demonstration was helpful in identifying how to operate close to or at design

capacity . In India, this is most important !