    RO (Reverse Osmosis)

    PlantPresentationPrepared By:

    Bilal Mushtaq(TMT Utilities)

  • 8/13/2019 Presentationof RO

    2/15

  • 8/13/2019 Presentationof RO

    3/15

  • 8/13/2019 Presentationof RO

    4/15

  • 8/13/2019 Presentationof RO

    5/15

  • 8/13/2019 Presentationof RO

    6/15

    P-101A,B,C,D T-100 Bag FilterP-102A/B/C

    UVSterilizerMMF A/B

    AntiScalant Dosing

    CartridgeFilter

    HP Pump A/B

    Buffer Tank36 Cu.m

    12 Cu.m Effluent waterwill drain in effluent pit.

    CartridgeFilter

    NaoH Dosing

    HP Pump A/B

    T-200

    AntiScalant Dosing

    CleaningTank

    Simulation Diagram Of RO Plant

    42 Cu.m water willcome in MMF

    6 Cu.m water will goto 1 st from 2 nd pass.

    CleaningPump

  • 8/13/2019 Presentationof RO

    7/15

    P-101A,B,C,D T-100 Bag FilterP-102A/B/C

    UVSterilizerMMF A/B

    CartridgeFilterHP Pump A/BBuffer Tank

    . To RO Effluent Pit

    CartridgeFilter

    HP Pump A/B

    T-200

    NOTE:Before start up the RO plant 20 minutes Manual Flushing of 1 st pass will

    be done To Drain the BIOCIDE From Membranes.For Flushing This Procedure Will Be followed.

    1. Open The start Menu and select Manual command.2. Open the Rejection valve of solenoid valve.3. Open the inlet valve of solenoid valve.4. Open the Valve #2 of MMF A/B.5. Open the valve #1of MMF A/B.6. After flushing reverse procedure will be followed and start the plant

    on AUTO or MANUAL mode.Green Thick Lines Show the Passing Way of Raw Water DuringFlushing.

    Manual Flushing Before Start the 1 st pass of ROplant

    To Cleaning Tank

  • 8/13/2019 Presentationof RO

    8/15

    Buffer Tank36 Cu.m

    12 Cu.m Effluent waterwill drain in effluent pit.

    CartridgeFilter

    HP Pump A/B

    T-200

    NOTE:Before start up the RO plant 20 minutes Manual Flushing of 2 nd pass will bedone to flush the Membranes.1 st pass will be in service and its permeate willtaken in buffer tank to flush the Membranes of 2 nd pass.

    For Flushing This Procedure Will Be followed.1. Open The start Menu and select Manual command.2. Open the Rejection valve of solenoid valve from PLC.3. Open the inlet valve of solenoid valve form PLC.4. Select the Pump #1 or 2 from PLC.5. After flushing reverse procedure will be followed and start the plant on

    AUTO or MANUAL mode.6. Green Thick Lines Show the Passing Way of Raw Water During Flushing.

    Manual Flushing Before Start the 2nd

    pass ofRO plant

    All water will be drain i neffluent pit during flushing .

    AntiScalant DosingTo Cleaning Tank

    P-101A,B,C,D T-100 Bag FilterP-102A/B/C

    UVSterilizerMMF A/B

    CartridgeFilter

    HP Pump A/B

  • 8/13/2019 Presentationof RO

    9/15

    P-101A,B,C,D T-100 Bag FilterP-102A/B/C

    UVSterilizerMMF A/B

    CartridgeFilter

    HP Pump A/BBuffer Tank

    CartridgeFilter HP Pump A/B

    T-200

    CleaningTank Cleaning

    Pump

    Biocide Dosing

    Note:After make up the level of treated water tank when we will stop the RO plantsecond flushing will be done for one minute.After second flushing treated water with Biocide will be add in 1 st pass ofRO by the force of cleaning pump in membranes to protect them from

    bacteria for One Minute.Green Thick Lines Show the Passing Way of Biocide Dosing.

    Biocide Dosing in 1 st pass of RO

  • 8/13/2019 Presentationof RO

    10/15

    Design Parameters Of RO 1 st Pass