XT-SeriesExpanding the Powerof FluorescentFlow Cytometry
Sysmax Manufacturers
• Sysmex was the first company to use fluorescent flow cytometry and cell counting methods to reliably detect abnormal samples and reduce false positives.
• Take advantage of our experience.
Sysmex XT-2000i
• The Sysmex XT-2000i is an automated hematology analyzer for in vitro diagnostic use. The XT-2000i can analyze and output the results of 24 parameters of a blood sample by using an optical detector block based on flow cytometry and a semiconductor laser.
Technologies
• Fluorescent Flow Cytometry method:
• DC sheath flow method:• SLS method:
• Fluorescent Flow Cytometry method:
• DC sheath flow method:• SLS method:
Parameters
There are 24 parameters
• WBC,RBC,HGB,HCT,MCV,MCH,MCHC,PLT
• Neut%, Lymph%, Mono%, Eo% ,Baso%
• Neut#, Lymph#, Mono#, Eo#, Baso#• RDW-SD,RDW-CV,MPV,RET
%,RET#,IRF
There are 24 parameters
• WBC,RBC,HGB,HCT,MCV,MCH,MCHC,PLT
• Neut%, Lymph%, Mono%, Eo% ,Baso%
• Neut#, Lymph#, Mono#, Eo#, Baso#• RDW-SD,RDW-CV,MPV,RET
%,RET#,IRF
Aspiration Volume
• 80 samples/hour • Sampler or manual closed mode:
150 µL• Manual open mode: 85 µL• Capillary mode: 40 µL
Throughput
Data Storage
•10,000 samples (incl .graphics)•5,000 patients ’information•1,000 selective test orders
Interfaces• Comprehensive
QC files including “Current ”and
“New ”lot feature
• line printer,• graphic printer
Quality Control
Standard•Rack sampler for 50 sample tubes•Hand-held barcode scanner
Fluorescent Flow Cytometry Makes the Difference
A difference in managing abnormal samples• Reliable detection of abnormal
samples remains the most important issue in the hematology laboratory.
• Accurate WBC, RBC, PLT and Differential results are essential to providing meaningful clinical information and in maintaining an efficient laboratory
Continue
• The xt-Series, which is comprised of the xt-2000i and the xt-1800i, use the identical and advanced Fluorescent Flow Cytometry technology and state-of-the-art cell counting methods.
• The xt-Series extensive panel of hematology parameters provides more comprehensive data for better clinical decisions.
Continue
• Fluorescent enhanced WBC Differential Counts• Fluorescent and Impendence Platelet Counts*• Fluorescent Reticulocytes and Immature Reticulocyte Fractions
Success of excellence
• Built on the modern Fluorescent Flow• Reliable system requiring minimum• Maintenance (just one shut-down
cycle/day)• Excellent WBC differential with low
review rate due to fluorochrome staining of
cells
Valuable informationwith diagnostic impact
• Reticulocyte enumeration including maturation indices for efficient
monitoring of the erythropoietin activity• Fluorescent optical platelets for
accurate plate-let counts even in case of mall RBC or large PLT
• Cumulative patient data and Delta Check
Easy-to-use
• Windows 2000 graphical user interface
• Q-Flags for quantitative flagging, adjustable according to laboratory
needs• Comprehensive software programs
for internal and external quality control on board
Cost effective
• Four random access selective test profiles
(CBC,CBC/DIFF,CBC/RET,CBC/DIFF/RET)• Real time bi-directional Host
communication• Network capability for integration into a productive laboratory
environment
Flexibility
• Information Processing Unit (IPU) with customizable display
Advantages of xt-2000I IN DIAGNOSIS
• Abnormalities in the WBC (myeloid) line
• Abnormalities in the WBC (lymphoid) line
• Abnormalities in the RBC line• Abnormalities in the PLT line