6
PRESBYOND Laser Blended Vision from ZEISS Customized. All distances. Immediate.

PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

PRESBYOND Laser Blended Vision from ZEISSCustomized. All distances. Immediate.

Page 2: PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

* In

refe

ren

ce t

o cl

inic

al o

utc

om

es a

s co

mp

ared

to

mo

no

visi

on.

Dat

a o

n fi

le.

Blending vision into better outcomes*.ZEISS PRESBYOND Laser Blended Vision ZEISS PRESBYOND Laser Blended Vision

A clear choice for patients with presbyopia

PRESBYOND® Laser Blended Vision from ZEISS is an advanced method for treating patients with age-related loss of accommodation, also known as presbyopia. It offers the opportunity to achieve freedom from glasses by combining the simplicity and accuracy of corneal refractive surgery with the benefits of increased depth of field in retaining visual quality. As a surgical solution based on the naturally occurring spherical aberrations of the eye, this ZEISS software extends the scope of customized ablation beyond the limits of conventional monovision laser methods in several ways.

Whether for its customized treatment profiles, its visual acuity at all distances, its indications range or its immediate impact, ZEISS PRESBYOND Laser Blended Vision is a clear treatment choice for the fast growing demographic of patients with presbyopia.

ZEISS PRESBYOND Laser Blended VisionCustomized. All distances. Immediate.

ZEISS PRESBYOND Laser Blended Vision

lets you greatly expand your ZEISS MEL® 80

or MEL 90 excimer laser treatment

repertoire and your patient base

3

// INSPIRATION MADE BY ZEISS

Page 3: PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

54

Conventional monovision

With conventional monovision treatment

methods, the dominant eye is corrected

for distance vision to almost plano while

the non-dominant eye is corrected for

near vision, usually up to -3.0 D. Optimal

vision is achieved at distance and near

range, requiring the brain to contend with

two separate images at different levels

of correction which not all patients can

tolerate.

Patients that do tolerate the method

are left with an uncorrected gap in the

intermediate range, the so-called “Blur

Zone.” In addition to the fuzzy image,

it can also cause other side effects

such as reduced contrast sensitivity and

stereoacuity.

ZEISS PRESBYOND Laser Blended Vision

As a physiologically optimized laser

treatment method for patients with

presbyopia, ZEISS PRESBYOND Laser

Blended Vision represents the next stage in

eye care excellence. Similar to conventional

monovision, the dominant eye is corrected

for distance vision to almost plano, whereas

the non-dominant eye is corrected to be

slightly myopic for near vision to -1.5 D.

This micro-monovision strategy is further

enhanced by a decisive difference: an

increase in the depth of field of each eye

using a wavefront-optimized ablation

profile to create a continuous refractive

power gradient for the whole optical

zone of the cornea. This ZEISS software

is an absolutely individualized treatment

plan based on the preoperative spherical

aberrations and the functional age of the

eye. As a result, a customized fusion of the

two images for near and distance vision

is created for each patient – the so-called

“Blend Zone.”

Although similar to conventional monovision laser methods in terms of the workflow, ZEISS PRESBYOND® Laser Blended Vision takes customized vision correction a step beyond, particularly with respect to the outcomes.

Next-level vision correctionbeyond conventional monovision

The unique Blend Zone

Essentially, the Blend Zone makes it easier for the brain to merge the images of

both eyes, thereby achieving true binocular vision. In addition to excellent near

and far vision, ZEISS PRESBYOND Laser Blended Vision patients also experience

very good visual acuity and contrast sensitivity in the intermediate range.

No increase in depth of field

No increase in depth

of field

Dominant eye

±0.0 D

Non-dominant eye

up to -3.0 D

DISTANCE

Increase in depth

of field

Increase in depth of field

Dominant eye

±0.0 D

Non-dominant eye

-1.5 D

NEAR

DISTANCE

NEAR

Page 4: PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

96 76 7

All distancesCustomized Immediate

Optimizing outcomes for patients with presbyopia ZEISS PRESBYOND Laser Blended Vision

Individualized ablations

ZEISS PRESBYOND® Laser Blended Vision is a truly

customized solution for treating presbyopic patients. It

incorporates preoperative wavefront data to fine-tune

the depth of field for each eye individually. The

functional age of the eye is also factored in. As a

result, a personalized ablation profile is created per

eye for optimized target refraction. The monovision

component can be pre-adjusted for the patient’s

tolerance level. Also, different optical zone sizes can

be selected to account for the patient’s pupil size.

Ideal for a growing demographic

As an optimized laser method for age-related

accommodation loss, ZEISS PRESBYOND Laser

Blended Vision is ideally suited for serving the

needs of patients 40-60 years of age – a fast-

growing demographic group interested in

sophisticated options. It is also one of the least

invasive methods for addressing this target group.

Familiar procedure

Following the same workflow as conventional

LASIK procedures, ZEISS PRESBYOND Laser

Blended Vision combines the convenient binocular

treatment planning of the CRS-Master® with the

proven comfort and workflow of the MEL® 80 or

MEL 90 excimer laser, all from ZEISS.

Outstanding visual acuity

By customizing each eye individually,

ZEISS PRESBYOND Laser Blended Vision provides

excellent visual acuity for near and distance

vision. Unlike traditional monovision methods,

PRESBYOND Laser Blended Vision also offers

good intermediate vision in the Blend Zone.

According to clinical studies, there is virtually no

loss of contrast sensitivity while stereoacuity is

maintained. Also, side effects such as multiple

images in one eye are almost eliminated.

An all-natural approach

ZEISS PRESBYOND Laser Blended Vision is a

physiologically optimized solution and a true

binocular method for treating patients with

presbyopia.

Wide indication range

ZEISS PRESBYOND Laser Blended Vision is a proven

and effective method for treating indications

ranging from -8.0 D to +2.0 D, including

emmetropic and astigmatic patients (up to +2.0 cyl).

Appropriate for most patients

A key advantage of ZEISS PRESBYOND Laser

Blended Vision is that it is proven to be tolerated

by more patients than conventional monovision.

It is effective for treating up to 97% of all

presbyopia-related forms of impairment as

compared to only 59–67% for conventional

monovision. Even patients with presbyopia also

affected by emmetropia and astigmatism can be

treated. In fact, it has the potential to achieve a

far greater success rate than any comparable

treatment along with giving patients the wow

effect of being able to read without glasses the

very same day. Thus, it positively impacts patients

and refractive surgeons alike – visually for the

former, economically for the latter.1-5

A competitive edge

ZEISS PRESBYOND Laser Blended Vision allows

practices already using a MEL 80 or MEL 90 excimer

laser and CRS-Master from ZEISS to significantly

expand their LASIK repertoire and increase the

patient base. As such, this ZEISS software offers a

decisive competitive advantage over other LASIK

practices only specializing in monovision treatment

methods.

Page 5: PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

MEL 80 and MEL 90 from ZEISS

Type ArF excimer laser

Wavelength 193 nm

Frequency MEL 80: 250 HzMEL 90: FLEXIQUENCE® 250 Hz / 500 Hz

Dimensions (W x D x H)

MEL 80: 1550 mm x 800 mm x 1490 mmMEL 80 with patient supporting system: 3140 mm x 1800 mm x 1490 mmMEL 90: 1360 mm x 730 mm x 1480 - 1700 mmMEL 90 with patient supporting system: 3230 mm x 2380 mm x 1700 mm

Surgical microscope OPMI® pico from ZEISS with integrated HD video camera

Active eye tracker Infrared, pupil and limbus tracking, 1050 frames per second (fps), manual ablation center selection, automatic Pupil Center Shift Correction

Beam dimensions 0.7 mm FWHM (full width at half maximum), Gaussian beam profile

VisuMax from ZEISS

System components Patient supporting system, including platform Integrated uninterruptible power supply (UPS)Surgical microscope with additional slit illuminationVideo camera with integrated recording

Femtosecond laser parameters

Wavelength 1043 nmLaser pulse rate 500 kHz

Recommended space requirements

180° setup with MEL 80 / MEL 90:4500 x 3800 mm90° setup with MEL 80 / MEL 90:4000 x 4000 mm

8 9

A perfect combination: The refractive system landscape of ZEISS

Technical data

Dimensions (W x D x H)

Max. 1060 x 420 x 1510 mm

Data transfer USB flash memory drive (USB memory stick)

Data printout Via network connection with Ethernet cable and optional network isolator

References

Claims made in this document are supported by

information provided in the following publications:

1. Reinstein DZ, Couch DG, Archer TJ. LASIK for Hyperopic Astigmatism and

Presbyopia Using Micro-monovision With the Carl Zeiss Meditec MEL 80.

J Refract Surg. 2009;25(1):37-58.

2. Reinstein DZ, Archer TJ, Gobbe M. LASIK for Myopic Astigmatism and

Presbyopia Using Non-Linear Aspheric Micro-Monovision with the

Carl Zeiss Meditec MEL 80 Platform. J Refract Surg. 2011;27(1):23-37.

3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of

presbyopia in emmetropic patients using aspheric ablation profiles and a

micro-monovision protocol with the Carl Zeiss Meditec MEL 80 and VisuMax.

J Refract Surg. 2012 [In Press].

4. Reinstein DZ, Archer TJ, Gobbe M. Stereoacuity after Corneal Presbyopic

LASIK in Myopic, Hyperopic and Emmetropic Patients. ESCRS Annual Meeting,

Vienna, September 2011.

5. Evans BJ. Monovision: a review. Ophthalmic Physiol Opt.

2007;27(5):417-439.

CRS-Master from ZEISS

000000-1429-382-04-GB-Vs01 MWIB

VISIBLE AND INVISBLE

LASER RADIATION AVOID EYE

OR SKIN EXPOSURE TO DIRECT

OR SCATTERED RADITION

CLASS 4 LASER PRODUCT

ACCORDING

DIN EN 60825-1:2003 UND :2008

193 nm, <2 mJ, 4-7 ns

Simple upgrade

PRESBYOND® Laser Blended Vision is an optional software

upgrade for the CRS-Master® from ZEISS. It forms a perfect

fit with the ZEISS MEL® 80 or MEL 90 excimer laser, expanding

the repertoire of customized refractive laser corrections far

beyond the limits of conventional monovision methods.

PRESBYOND Laser Blended Vision and CRS-Master

from ZEISS are not intended for sale in the

United States.

Laser warning sign MEL 80/90 Laser warning sign VisuMax

Precise flaps

The ZEISS VisuMax® creates flaps of a highly predictable

thickness and of adjustable geometries for Femto-LASIK and

ZEISS PRESBYOND Laser Blended Vision – the recommended

treatment option for patients with presbyopia.

Page 6: PRESBYOND Laser Blended Vision from ZEISS Customized. All ... · 3. Reinstein DZ, Carp GI, Archer TJ, Gobbe M. LASIK for the correction of presbyopia in emmetropic patients using

Carl Zeiss Meditec AG Goeschwitzer Strasse 51–5207745 JenaGermany www.meditec.zeiss.com/contacts www.zeiss.com/presbyond

EN_

34_0

10_0

003I

II

Prin

ted

in G

erm

any

CZ-IX

/201

7Th

e co

nten

ts o

f the

bro

chur

e m

ay d

iffer

from

the

curre

nt s

tatu

s of

app

rova

l of t

he p

rodu

ct o

r ser

vice

offe

ring

in y

our c

ount

ry. P

leas

e co

ntac

t our

regi

onal

repr

esen

tativ

es fo

r mor

e in

form

atio

n. S

ubje

ct to

cha

nges

in d

esig

n an

d sc

ope

of d

eliv

ery

and

due

to o

ngoi

ng te

chni

cal d

evel

opm

ent.

PRES

BYO

ND,

CRS

-Mas

ter,

MEL

and

Visu

Max

are

eith

er tr

adem

arks

or r

egist

ered

trad

emar

ks o

f Car

l Zei

ss M

edite

c AG

or o

ther

com

pani

es o

f the

ZEI

SS G

roup

Car

l Zei

ss M

edite

c AG

, 201

7. A

ll ri

ghts

res

erve

d.

0297