36
Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig Department of Agricultural and Biological Engineering Laboratory of Renewable Resources Engineering Department of Statistics

Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors

Nathan S. Mosier and Bruce Craig

Department of Agricultural and Biological EngineeringLaboratory of Renewable Resources Engineering

Department of Statistics

Page 2: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Acknowledgements› This research was supported through a cooperative agreement with

the ARS of the United States Department of Agriculture, project number 1935-42000-035.

› Eastern Regional Research Center

› Center for Food Safety Engineering

› Yifei Zang, Benjamin Tyner

› Laboratory of Renewable Engineering Faculty, Staff, and Students– Dr. Michael R. Ladisch, LORRE Director

– Dr. Tom Huang, Xingya Liu, Amanda Stewart, Wan-Tzu Chen, and Miroslav Sedlak

Page 3: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Food Borne Pathogens

Feces/manure

Raw meat

Soil, food processing environment

Common sources

As few as 10 cellsunknownInfectious dose

Hemorrhagic colitis Gastroenteritis

Stillbirth

Death

Symptoms

2-5 days> 1-5 daysIncubation period

E. coli O157:H7L. monocytogenesBACTERIA

www.foodsafety.gov http://www.cfsan.fda.gov/~mow/intro.html

Page 4: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Listeria monocytogenes

Gram positive (1x 2 μm )

Grows at 1 to 45 ºC

Acid and salt tolerant

Annual cases >2,500; Mortality 20-28%

Page 5: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Rapid detection of bacteria

NoNoYesYes Live/Dead

YesYesNoYesIdentification

Growth Based

Nucleic Acid-based

Cell Comp. Based

Viability Based

Technique

Features

Growth steps required to provide live/ dead information

Using selective media

Our research addresses growth-based and cell-component based approaches to provide

live/dead and ID information

Through antibody-based capture

How/why?

Adapted from M.R. Ladisch, presentation to USDA-ARS-EERC, 8 November 2004

Page 6: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

2. Macro Level,

16 wells on a cartridge

1. Petri Dish

3. Micro Level,

On-Chip culture

Evolution of Growth Detection

Page 7: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

NeedsRapid detection during food processing

Elapsed time between sampling and result (time to result) of 3 hours or less

Detection against background of other non-pathogenic organisms

Page 8: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Pathogen Detection on Biochips

Page 9: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Microchips: Can be made in large numbers

•Microchips for adsorption studies

•PECVD fabricated oxide layer

•SiO2 with Pt patterns

Page 10: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Jennifer Sturgis, BMS

Paul Robinson, BMS, BME

Arun Bhunia, Food Sci

Rashid Bashir, ECE

Rafael Gomez, ECE

Glass cover

In/Out ports

Channels/Wells

Epoxy adhesive

Pin

10 mm

Page 11: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Silicon substrate

Pt electrode SiO2 insulation

Glass coverGlass cover

Z Z

Target molecules Target molecules bound to receptorsbound to receptors

Other molecules in theOther molecules in thesolution will solution will notnot bindbind

Receptors immobilized on electrode

Protein Biochip Technology Platform

Page 12: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Micro-fabricated Biochip for Bacterial Cell Culture

PC boardw. heater

Wire-bond(with epoxy)

Micro-fluidicTubes

Micro-fluidicTubes

Edge Connector

MicroscopeObjective

BioChip

Measurementelectrodes

DEP captureelectrodes

Outlet Inlet

Measurementelectrodes

DEP captureelectrodes

Outlet Inlet

Page 13: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Challenge

Food Sample

Detection volume

ERRC, 2000

10-100 mL

Dilute Cells

0.10-10 uL

Captured Cells

>1000x size change

Page 14: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

General strategy for present work:Recovery of live bacteria

Page 15: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

2. Extract Microorganisms

In order of decreasing severityblender > stomacher > massage

machine2 min air

(froth)20°CDecant intostomacher bag

2 minin air

20°CIn stomacher

bag

2 minin air20°CIn stomacher

bag

Page 16: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Homogenized Hotdog ExperimentBefore blending the hotdog

Page 17: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Homogenized Hotdog Experiment After hotdog was blended

Page 18: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Massaged Hotdog Experiment

Page 19: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

General strategy for present work:Recovery of live bacteria

Page 20: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

25 mm filter holder25 mm filter holder

47 mm filter holder47 mm filter holder

Air SpaceAir Space

CCR Kit Assembly•Microfiltration basis

•Designed to capture and recover bacterial cells from a food-derived sample

•Uses membranes in series to process 100 mL hot dog extract into 0.1 to 1 mL sample

Cell Concentration and Recovery

Page 21: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

CCR Method

Page 22: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

CCR Work Summary› Careful selection of membranes

– Pore size and distribution

– Surface chemistry

– Interaction of target cell

2.5µm depth filter – 47mm diaPRE-FILTER

0.4µm screen filter – 25mm diacapture and conc. bacteria

Top downSide viewTop downSide view

1µm10µm

SEM by Chia-Ping Huang

Page 23: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Depth Filter Before Use

WhatmanWhatman 42 42

10μ1800X 5kV41133

Page 24: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Screen Filter Before Use

0.4 micron Polycarbonate0.4 micron Polycarbonate

1μ8000X 5kV41135

Page 25: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Membrane Properties

Polycarbonate membrane

1 μm

Page 26: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Bacterial cells recovered in 500 µLfrom hot dog meat broth containing 15 cells/ mL

y = 10.352x - 1.2721R2 = 0.9863

0

200

400

600

800

1000

1200

0 20 40 60 80 100Filtered volume(ml)

num

ber

of c

ells

rec

over

ed

cell number vs. filtered volume

Linear (cell number vs. filteredvolume)

Chen et al, 2004

~1500 cells/mL

Page 27: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Validating Location of CellsNeed to “see” cells for rapidly screening different filtration and

sensing systems:

led to use of GFP bacteria

red or green E. coli

green L. monocytogenes

(Applegate and Sedlak, 2004)

Page 28: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Wilson et al. (2001) Infect. Immun.

Mutant GFP protein – GFP-mut3

Fortineau et al. (2000) Res. Microbiol.

Mutant GFP protein – GFP-mut1Listeria monocytogenes ATCC 23074

Expressing Fluorescent Proteins

Page 29: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

GFP L. monocytogenes

Page 30: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

RFP E. coli and GFP L monocytogenes

Page 31: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Sampling Issue

› How high a concentration is needed in sample introduced to biochip to guarantee detection of cells?

› How much volume must be processed from hot dog sample to guarantee capture of at least one cell?

Page 32: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

SYSTEM CHARACTERIZATION

› Uneven distribution of microbes – Graininess;

› Uneven distribution of sample matrices.

› Variability

› Poor reproducibility

Page 33: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Distribution of GFP E. coli

108 cells/mL10X

Page 34: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Distribution of GFP E. coli

107 cells/mL10X

Page 35: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Distribution of GFP E. coli

106 cells/mL10X

Page 36: Predicting Cell Capture from Dilute Samples for ... cell capture-Mosier.pdf · Predicting Cell Capture from Dilute Samples for Microfluidic Biosensors Nathan S. Mosier and Bruce Craig

Distribution of GFP E. coli

105 cells/mL10X