21
Structural Engineering & Geospatial Consultants PRECAST CONCRETE STRUCTURES 1. INTRODUCTION The concept of precast (also known as “prefabricated”) construction includes those buildings, where the majority of structural components are standardized and produced in plants in a location away from the building, and then transported to the site for assembly. These components are manufactured by industrial methods based on mass production in order to build a large number of buildings in a short time at low cost.

PRECAST CONCRETE STRUCTURES - جامعة نزوى · 2016. 4. 4. · Structural Engineering & Geospatial Consultants PRECAST CONCRETE STRUCTURES 1.INTRODUCTION The concept of precast

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • Structural Engineering & Geospatial Consultants

    PRECAST CONCRETE STRUCTURES

    1. INTRODUCTION

    The concept of precast (also known as “prefabricated”) construction includes

    those buildings, where the majority of structural components are standardized and

    produced in plants in a location away from the building, and then transported to the site

    for assembly. These components are manufactured by industrial methods based on mass

    production in order to build a large number of buildings in a short time at low cost.

  • Structural Engineering & Geospatial Consultants

    The main features of this construction process are as follows:

    The division and specialization of the human workforce

    The use of tools, machinery, and other equipment, usually automated, in the

    production of standard, interchangeable parts and products

    Compared to site-cast concrete, precast concrete erection is faster and less

    affected by adverse weather conditions.

    Plant casting allows increased efficiency, high quality control and greater control

    on finishes..

    This type of construction requires a restructuring of entire conventional construction

    process to enable interaction between design phase and production planning in order to

    improve and speed up construction.

    1.1 TYPES OF PRECAST SYSTEMS

    Depending on the load-bearing structure, precast systems can be divided into the following

    categories:

    Large-panel systems

    Frame systems

    Slab-column systems with walls

    Mixed systems

  • Structural Engineering & Geospatial Consultants

    1. 1. 1 LARGE PANEL SYSTEMS

    The designation “large-panel system” refers to multistory structures composed of

    large wall and floor concrete panels connected in the vertical and horizontal directions so

    that the wall panels enclose appropriate spaces for the rooms within a building. These

    panels form a box-like structure. Both vertical and horizontal panels resist gravity load.

    Wall panels are usually one story high. Horizontal floor and roof panels span either as

    one-way or two-way slabs. When properly joined together, these horizontal elements

    act as diaphragms that transfer the lateral loads to the walls.

    Depending on wall layout , there are three basic configurations of large-panel buildings:

    Cross-wall systems

    Longitudinal wall systems

    Two-way systems

    A large-panel concrete building under construction

  • Structural Engineering & Geospatial Consultants

    1. 1. 2 FRAME SYSTEMS

    Precast frames can be constructed using either linear elements or spatial beam-

    column sub-assemblages. Precast beam-column sub-assemblages have the advantage that

    the connecting faces between the sub-assemblages can be placed away from the critical

    frame regions; however, linear elements are generally preferred because of the

    difficulties associated with forming, handling, and erecting spatial elements. The use of

    linear elements generally means placing the connecting faces at the beam-column

    junctions. The beams can be seated on corbels at the columns, for ease of construction

    and to aid the shear transfer from the beam to the column. The beam-column joints

    accomplished in this way are hinged. However, rigid beam-column connections are used in

    some cases, when the continuity of longitudinal reinforcement through the beam-column

    joint needs to be ensured. The components of a precast reinforced concrete frame are

    shown in Figure

  • Structural Engineering & Geospatial Consultants

    1. 1. 3 SLAB-COLUMN SYSTEMS WITH SHEAR WALLS

    These systems rely on shear walls to sustain lateral load effects, whereas the

    slab-column

    structure resists mainly gravity loads. There are two main systems in this category:

    • Lift-slab system with walls

    • Prestressed slab-column system

    In the Lift –slab system, the load-bearing structure consists of precast

    reinforced concrete columns and slabs,. Precast columns are usually two stories high. All

    precast structural elements are assembled by means of special joints. Reinforced

    concrete slabs are poured on the ground in forms, one on top of the other. Precast

    concrete floor slabs are lifted from the ground up to the final height by lifting cranes.

    The slab panels are lifted to the top of the column and then moved downwards to the

    final position. Temporary supports are used to keep the slabs in the position until the

    connection with the columns has been achieved.

    A lift-slab building

  • Structural Engineering & Geospatial Consultants

    The prestressed slab-column system uses horizontal prestressing in two

    orthogonal directions to achieve continuity. The precast concrete column elements are 1

    to 3 stories high. The reinforced concrete floor slabs fit the clear span between

    columns. After erecting the slabs and columns of a story, the columns and floor slabs are

    prestressed by means of prestressing tendons that pass through ducts in the columns at

    the floor level and along the gaps left between adjacent slabs. After prestressing, the

    gaps between the slabs are filled with in situ concrete and the tendons then become

    bonded with the spans. Seismic loads are resisted mainly by the shear walls (precast or

    cast-in-place) positioned between the columns at appropriate locations.

    Post-tensioned slab-column connection

  • Structural Engineering & Geospatial Consultants

    2. PRECAST CONCRETE STRUCTURAL ELEMENTS

    1.1 Precast Slabs

    1.2 Precast Beam & Girders

    Hollow core slabs

  • Structural Engineering & Geospatial Consultants

    1.3 Precast Columns

    1.4 Precast Walls

    Inverted Tee beams supported on precast columnsPrecast columns

  • Structural Engineering & Geospatial Consultants

    1.5 Other Elements

    2.

    Precast concrete Stairs Uniquely shaped structural elements for a sports stadium

  • Structural Engineering & Geospatial Consultants

    DESIGN CONCEPTS FOR PRECAST CONCRETE BUILDINGS

    The design concept of the precast buildings is based on the buildability,

    economy and standardization of precast components.

  • Structural Engineering & Geospatial Consultants

    In design of precast members and connections, all loading and restraint conditions from

    casting to end use of the structure should be considered. The stresses developed in precast

    elements during the period from casting to final connection may be more critical than the service

    load stresses. Special attention should be given to the methods of stripping, storing,

    transporting, and erecting precast elements.

    When precast members are incorporated into a structural system, the forces and

    deformations occurring in and adjacent to connections (in adjoining members and in the entire

    structure) should be considered. The structural behavior of precast elements may differ

    substantially from that of similar members that are monolithically cast in place. Design of

    connections to transmit forces due to shrinkage, creep, temperature change, elastic

    deformation, wind forces, and earthquake forces require special attention. Details of such

    connections are especially important to insure adequate performance of precast structures.

    Precast members and connections should be designed to meet tolerance requirements. The

    behavior of precast members and connections is sensitive to tolerances. Design should provide

    for the effects of adverse ccombinations of fabrication and erection tolerances. Tolerance

    requirements should be listed on contract documents, and may be specified by reference to

    accepted standards. Tolerances that deviate from accepted standards should be so indicated.

  • Structural Engineering & Geospatial Consultants

    All details of reinforcement, connections, bearing elements, inserts, anchors, concrete

    cover, openings and lifting devices, and specified strength of concrete at critical stages of

    fabrication and construction, should be shown on either the contract documents prepared by the

    architect/engineer ofrecord or on the shop drawings furnished by the contractor. Whether this

    information is to be shown on the contract documents or shop drawings depends on the provisions

    of the contract documents. The shop drawings should show, as a minimum, all details of the

    precast concrete members and embedded items. The contract documents may specify that

    portions of connections exterior to the member are also to be shown on the shop drawings. The

    contract documents may also require the contractor to provide designs for the members and/or

    connections.

    The contract documents should show the loads to be considered in design of the precast

    concrete elements of the structure, and they should indicate any special requirements or

    functions (for example: seismic loads, allowance for movements, etc.) that should be considered

    in design assigned to the contractor. In this case, the shop drawings should include complete

    details of the connections involved.

    Precast concrete structure consisting of solid wall panels and hollow core slabs.

  • Structural Engineering & Geospatial Consultants

    A single story warehouse consisting of double tees supported by insulated sandwich wall panels.

  • Structural Engineering & Geospatial Consultants

    3. TYPICAL CONNECTION OF PRECAST CONCRETE ELEMENTS

    COLUMN TO COLUMN CONNECTION

  • Structural Engineering & Geospatial Consultants

    BEAM TO COLUMN CONNECTION

  • Structural Engineering & Geospatial Consultants

    SLAB TO BEAM CONNECTION

  • Structural Engineering & Geospatial Consultants

    WALLPANEL CONNECTED TO INSITU CONCRETE

  • Structural Engineering & Geospatial Consultants

  • Structural Engineering & Geospatial Consultants

    CONNECTION BETWEEN SLABS

  • Structural Engineering & Geospatial Consultants

    CORNER CONNECTIONS OF WALL PANELS

  • Structural Engineering & Geospatial Consultants

    CONNECTION OF WALL PANELS TO COLUMNS

    4. PRECAST CONCRETE CONSTRUCTION AND SEISMIC DESIGN

    There is a general concern regarding the seismic performance of precast construction.

    It is noticed that large panel construction performs better than frame system.

    However, in areas of high seismic risk, structures must be designed to respond safely to

    the dynamic forces imparted into the structure. Innovations in joint design are improving theconnection systems in precast concrete structures and making them increasingly suitable for use in such

    areas.

    Information, pictures, photographs etc of the paper have been taken from

    www.bca.gov.sg/publications/BuildabilitySeries/others/bsl_cp3.pdf

    www.cpci.ca

    Precast industrial buildings detailing manual by National Precast Concrete Association Australia

    www.world-housing.net/uploads/precast__concrete.pdf

    Precast construction by Svetlana Brzev, British Columbia Institute of Technology, Canada ,Teresa Guevara-Perez,

    Architect, Venezuela

    ACI 550R-96, Design recommendations of precast Concrete Structures.

    Precast.ppt by Fundamental of Building construction , Materials & Methods, 5th Edition