27
© 2019 Cooper Lighting Solutions. All rights reserved. PR4 Sales Guide Cooper Lighting Solutions

PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

© 2019 Cooper Lighting Solutions. All rights reserved.

PR4 Sales GuideCooper Lighting Solutions

Page 2: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

HALO Commercial PR4Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

2

Product Features• Selectable - low lumen 1000/1500/2000 lm

• Selectable - high lumen 2000/3000/4000 lm

• SeleCCTable color temperature: 3000/3500/4000K

• CRI options: 80 or 90 CRI

• Medium / Wide beam polymer reversable “flip” lens included (in medium position)

• Finish options: matte white, matte metallic silver, dark bronze

• New Construction: Housing Frame & Driver

• Retrofit Kit: Junction box and driver - retrofit 5.1” min. to 5.75” max. apertures

Value Proposition• Field SeleCCTable lumens and color temperature

• High Lumen and Low Lumen options

• Extremely versatile with new construction and retrofit options

Target Application• Commercial, non-residential

Vertical Segment

Residential

Office ✓

Hospitality ✓

Retail ✓

Healthcare ✓

Product DescriptionHalo Commercial = Efficiency + Value. And PR4 series 4-inch semi-regressed lens LED downlight delivers with available new construction, retrofit, and surface cylinder models. The PR4 series LED modules feature field SeleCCTable color temperatures, field selectable lumens, plus medium & wide beam reversible lens option included for ultimate flexibility saving customers time and money. Suitable for general area commercial lighting with intended applications of healthcare, hospitality, and institutional utility spaces.

New ConstructionRetrofit

Low Lumen1000/1500/2000

High Lumen2000/3000/4000

Page 3: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

HALO Commercial PR4

3

Product Features• Selectable - low lumen 1000/1500/2000 lm

• Selectable - high lumen 2000/3000/4000 lm

• SeleCCTable color temperature: 3000/3500/4000K

• CRI options: 80 or 90 CRI

• Medium / Wide beam polymer reversable “flip” lens included (in medium position)

• One-piece construction of durable spun aluminum

• Works with both PR4M12* low lumen and PR4M24* high lumen LED modules

• Flush ceiling installation to 4” round, 3-1/2” and 4” octagonal and square junction boxes

• Listed for wet locations in protected ceilings

• Integral LED driver

• Finish options: matte white, matte metallic silver, dark bronze

Value Proposition• High Lumen and Low Lumen options

• Field SeleCCTable

Target Application• Commercial, non-residential

Vertical Segment

Residential

Office ✓

Hospitality ✓

Retail ✓

Healthcare ✓

Product DescriptionHalo Commercial = Efficiency + Value. And PR4 series 4-inch semi-regressed lens LED downlight delivers with available new construction, retrofit, and surface cylinder models. The PR4 series LED modules feature field SeleCCTablecolor temperatures, field selectable lumens, plus medium & wide beam reversible lens option included for ultimate flexibility saving customers time and money. Suitable for general area commercial lighting with intended applications of healthcare, hospitality, and institutional utility spaces.

Surface Cylinder

Matte White

Matte Metallic Silver

Dark Bronze

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 4: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR44-inch Selectable LED Downlight

Housing Frame • Boat-shaped for new construction or remodeling• Plaster lip pre-set 1/2“, adjusts for ceilings up to 1-1/2" thick

Adjustable Mounting Brackets• Brackets adjust 2" vertically and remove for remodel installation• Brackets work with the included “No Fuss” bars or 1/2" EMT

Junction Box• Listed for (8) #12 AWG 90° C conductors (4-in/4-out)• Listed for feed through branch wiring• (3) 1/2" and (2) 3/4" trade size pry-outs • Low voltage barrier section for 0-10V dimming wires• (3) 4-port push wire nuts (1-port is fixture connection)

No Fuss Bar Hangers™• Pre-installed and centered mounting bars• Bars lock T-grid with screwdriver or pliers, and have holes for sheet metal screws

4

1

2

3

4

New Construction frame

1

1

2

3

4

2

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Remodeler frame w/o bar hangers/brackets

Page 5: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR44-inch Selectable LED Retrofit Downlight

Retrofit Arm• Durable die-formed galvanized steel• One-piece construction• Attaches to LED module with 2- knurled thumb screws• For installation from below the ceiling into existing commercial open frames• Retrofit 5.1” min. to 5.75” max. Apertures (up to 7" with oversize trim ring)

Junction Box• Listed for (8) #12 AWG 90° C conductors (4-in/4-out)• Listed for feed through branch wiring• (3) 1/2" and (2) 3/4" trade size pry-outs • Low voltage barrier section for 0-10V dimming wires• (3) 4-port push wire nuts (1-port is fixture connection)

Oversized Trim Ring • OT450P oversize trim ring retrofits up to 7” max. aperture

5

1

2

31

2

OT450P Oversize trim ring

3

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 6: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR44-inch Selectable LED Downlight

6

PR4M* Series LED Modules• Field SeleCCTable CCT

• Field Selectable Lumens• Factory settings (pre-set at factory)

• 3500K• Low lumen 2000 lm• High lumen 4000 lm

• Medium / Wide beam reversable “flip” lens• Medium beam position pre-set at factory• Wall wash louver & lens kit optional accessory• Finishes: matte white, matte metallic silver, dark bronze

SeleCCTableCCT4000K3500K*3000K

SelectableLumen4000lm*3000lm2000lm

High Lumen

SeleCCTableCCT4000K3500K*3000K

SelectableLumen2000lm*1500lm1000lm

Low Lumen

Low Lumen1000/1500/2000

High Lumen2000/3000/4000

*Factory pre-set CCT & lumens

Matte White

Matte Metallic Silver

Wall Wash Kit

Dark Bronze

Medium / Wide beam “flip” lens

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 7: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR44-inch Selectable LED Downlight

7

LumaWatt Pro – EnlightedTilemount Sensor & Control

WaveLinx Tilemount Sensor Kit

DLVPSaves up to

40%

Emergency Backup with Remote Test Switch• Emergency battery backup 7W or 14W• Available on new construction and retrofit kits only• Factory installed (use with “D010” standard driver)

DLVP distributed low voltage power • “DLV” low voltage dimming driver - available on new

construction & retrofit• Remote emergency options available in DLV• Order separately – 300W or 600W LV power supply and

pre-terminated LV cables (see DLVP design guide)

LumaWatt Pro - Enlighted• “LWPD1” controller, tile mount wireless sensor

WaveLinx• WaveLinx: “WTA” relay w/ 0-10V dimming, tile mount

sensor and control

LumaWatt Pro - Enlighted & WaveLinx - factory installed (use with “D010” driver – not available with “DLV” driver)

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 8: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR4R – New ConstructionStandard 0-10V Dimming Driver

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

HOUSING PR4 FS12 D010 REM7 LED MODULE PR4M 12 MD 8FS MW PR4WW

Housing Lumens (Nominal) Driver Options LED Module Lumens (Nominal) Lens / Beam CRI / CCT Finish Accessory

PR4 = 4" new construction and remodeler frame

PR4CP = 4" Chicago Plenum new construction and remodeler frame CCEA construction

Field SelectableFS12 = selectable 1000 / 1500 / 2000 lumens, use with PR4M12* LED module

FS24 = selectable 2000 / 3000 / 4000 lumens, use with PR4M24* LED module

Fixed, Factory Set10 = 1000 lumens, use with PR4M12* LED module

15 = 1500 lumens, use with PR4M12* LED module

30 = 3000 lumens, use with PR4M24* LED module

D010 = 120 -277V 50/60Hz 0 – 10V 1% -100% dimming

REM7 = 7W Remote Emergency battery w/ remote indicator & test switch (D010 only) 1

REM14 = 14W Remote Emergency battery w/ remote indicator & test switch (D010 only) 1

PR4M = 4" LED module

12 = selectable 1000 / 1500 / 2000,Preset 2000 lmUse with PR4FS12*, PR410*, PR415* frames

24 = selectable 2000 / 3000 / 4000, Preset 4000lmUse with PR4FS24*, PR430* frames

MD = medium / wide beam reversible lens. Factory set for medium. Tool-less turn-to-lock reversal changes from medium to wide

8FS = 80 CRI Selectable 3000 / 3500 /4000K Preset 3500K9FS = 90 CRI Selectable 3000 / 3500 /4000K Preset 3500K

827 = 80CRI/ 2700K830 = 80CRI/ 3000K835 = 80CRI/ 3500K840 = 80CRI/ 4000K

927 = 90CRI/ 2700K930 = 90CRI/ 3000K935 = 90CRI/ 3500K940 = 90CRI/ 4000K

MW = matte white

MMS = matte metallic silver

BZ = dark bronze

PR4WW= wall wash kit, field installed

PR4MDWD= 4” reversible medium / wide lens -replacement part

OT450P = Oversize metal retrofit ring with 5.5” ID opening, 8” OD flangeFootnote:

1 Not available in Chicago Plenum

LWTPD1 = Factory installed LumaWattPro - Enlighted tile mount sensor kit (D010 only) 1

WTA = Factory installed WaveLinx tile mount sensor kit (D010 only)1

ACCESSORIES

HB128APK = L channel hanger bar, 26", ‘No-Fuss’, pair (replacement part kit)RMB22 = Adjustable wood joist mounting bars, pair, extend to 22” long (field installed)H347 = Step down transformer 347V input, 75VA max H347200 = Step down transformer 347V input, 200VA maxPORLWTPD1 = Field installed LumaWatt Pro – Enlighted Sensor kit (D010 only)WTA = Field installed WaveLinx sensor kit (D010 only)

Page 9: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR4 – New ConstructionDistributed Low Voltage Driver

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

HOUSING PR4 15 DLV REMV7 LED MODULE PR4M 12 MD 8FS MW PR4WW

Housing Lumens (Nominal) Driver Options LED Module Lumens (Nominal) Lens / Beam CRI / CCT Finish Accessory

PR4 = 4" new construction and remodeler frame

Fixed, Factory Set10 = 1000 lumens, use with PR4M12* LED module

15 = 1500 lumens, use with PR4M12* LED module

20 = 2000 lumens, use with PR4M12* LED module or PR4M24* LED module

30 = 3000 lumens, use with PR4M24* LED module

40 = 4000 lumens, use with PR4M24* LED module

DLV = distributed low voltage dimming driver (1%-100%)

For use with Eaton’s DLVP system only

Refer to DLVP LV power module & DLVP specifications for details1

REMV7 = 7W Remote Emergency battery w/ remote indicator & test switch (DLV only) 1, 2REMV14 = 14W Remote Emergency battery w/ remote indicator & test switch (DLV only) 1, 2

PR4M = 4" LED module

12 = 1000 / 1500 / 2000 lumens, Use with PR410*, PR415*, PR420* frames

24 = 2000 / 3000 / 4000 lumens, Use with PR420*, PR430*, PR440* frames

MD = medium / wide beam reversible lens. Factory set for medium. Tool-less turn-to-lock reversal changes from medium to wide

8FS = 80 CRI Selectable 3000 / 3500 /4000K Preset 3500K9FS = 90 CRI Selectable 3000 / 3500 /4000K Preset 3500K

827 = 80CRI/ 2700K830 = 80CRI/ 3000K835 = 80CRI/ 3500K840 = 80CRI/ 4000K

927 = 90CRI/ 2700K930 = 90CRI/ 3000K935 = 90CRI/ 3500K940 = 90CRI/ 4000K

MW = matte white

MMS = matte metallic silver

BZ = dark bronze

PR4WW= wall wash kit, field installed

PR4MDWD= 4” reversible medium / wide lens -replacement part

OT450P = Oversize metal retrofit ring with 5.5” ID opening, 8” OD flange

Footnote:1 Not available in Chicago Plenum2 ULusListed U.S. only

ACCESSORIES

HB128APK= L channel hanger bar, 26”, ‘No-Fuss’, pair (replacement)RMB22 = Adjustable wood joist mounting bars, pair, extend to 22” long

Page 10: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

10

LOW LUMEN MODULE1000lm / 1500lm / 2000lm

Halo Commercial PR4 – New Construction4-inch Selectable LED Downlight

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 11: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

11

HIGH LUMEN MODULE2000lm / 3000lm / 4000lm

Halo Commercial PR4 – New Construction4-inch Selectable LED Downlight

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 12: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

HOUSING PR4R FS12 D010 REM7 LED MODULE PR4M 12 MD 8FS MW PR4WW

Housing Lumens (Nominal) Driver OptionsLED Module Lumens (Nominal) Lens / Beam CRI / CCT Finish Accessory

PR4R = 4" retrofit kit, frame arm w/ J-Box, retrofit 5.1” to 5.75” aperture and up to 7” max. w/ OT450P accessory ring

PR4RCP = 4" Chicago Plenum retrofit kit, frame arm w/ J-Box, CCEA rated, retrofit 5.1” to 5.75” aperture and up to 7” max. w/ OT450P accessory ring

Field SelectableFS12 = selectable 1000 / 1500 / 2000 lumens, use with PR4M12* LED module

FS24 = selectable 2000 / 3000 / 4000 lumens, use with PR4M24* LED module

Fixed, Factory Set10 = 1000 lumens, use with PR4M12* LED module

15 = 1500 lumens, use with PR4M12* LED module

30 = 3000 lumens, use with PR4M24* LED module

D010 = 120 -277V 50/60Hz 0 – 10V 1% -100% dimming

REM7 = 7W Remote Emergency battery w/ remote indicator & test switch (D010 only) 1

REM14 = 14W Remote Emergency battery w/ remote indicator & test switch (D010 only) 1

PR4M = 4" LED module

12 = selectable 1000 / 1500 / 2000 lumens, Preset 2000lm, Use with PR4RFS12*, PR4R10*, PR4R15* retrofit

24 = selectable 2000 / 3000 / 4000 lumens, Preset 4000lm, Use with PR4RFS24*, PR4R30* retrofit

MD = medium / wide beam reversible lens. Factory set for medium. Tool-less turn-to-lock reversal changes from medium to wide

8FS = 80 CRI Selectable 3000 / 3500 /4000K Preset 3500K9FS = 90 CRI Selectable 3000 / 3500 /4000K Preset 3500K

827 = 80CRI/ 2700K830 = 80CRI/ 3000K835 = 80CRI/ 3500K840 = 80CRI/ 4000K

927 = 90CRI/ 2700K930 = 90CRI/ 3000K935 = 90CRI/ 3500K940 = 90CRI/ 4000K

MW = matte white

MMS = matte metallic silver

BZ = dark bronze

PR4WW= wall wash kit, field installed

PR4MDWD= 4” reversible medium / wide lens -replacement part

OT450P = Oversize metal retrofit ring with 5.5” ID opening, 8” OD flange

Footnote:1 Not available in Chicago Plenum

LWTPD1 = Factory installed LumaWattPro - Enlighted tile mount sensor kit (D010 only) 1

WTA = WaveLinx tile mount sensor kit (D010 only)1

ACCESSORIES

H347 = Step down transformer 347V input, 75VA max H347200= Step down transformer 347V input, 200VA maxPORLWTPD1 = Field installed LumaWatt Pro - EnlightedSensor kit (D010 only)WTA = Field installed WaveLinx sensor kit (D010 only)

Halo Commercial PR4R – Retrofit KitStandard 0-10V Dimming Driver

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 13: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

HOUSING PR4R 15 DLV REMV7 LED MODULE PR4M 12 MD 8FS MW PR4WW

Housing Lumens (Nominal) Driver OptionsLED Module Lumens (Nominal) Lens / Beam CRI / CCT Finish Accessory

PR4R = 4" retrofit kit, frame arm w/ J-Box, retrofit 5.1” to 5.75” aperture and up to 7” max. w/ OT450P accessory ring

Fixed, Factory Set10 = 1000 lumens, use with PR4M12* LED module

15 = 1500 lumens, use with PR4M12* LED module

20 = 2000 lumens, use with PR4M12* LED module or PR4M24* LED module

30 = 3000 lumens, use with PR4M24* LED module

40 = 4000 lumens, use with PR4M24* LED module

DLV = distributed low voltage dimming (1%-100%) driver

For use with DLVP system only

Refer to DLVP low-voltage power module & DLVP specifications for details1

REMV7 = 7W Remote Emergency battery w/ remote indicator & test switch (DLV only) 1, 2REMV14 = 14W Remote Emergency battery w/ remote indicator & test switch (DLV only) 1, 2

PR4M = 4" LED module

12 = 1000 / 1500 / 2000 lumens, Preset 2000lm, Use with PR4R10*, PR4R15*, PR4R20* retrofit

24 = 2000 / 3000 / 4000 lumens, Preset 4000lm, Use with PR4R20*, PR4R30*, PR4R40* retrofit

MD = medium / wide beam reversible lens. Factory set for medium. Tool-less turn-to-lock reversal changes from medium to wide

8FS = 80 CRI Selectable 3000 / 3500 / 4000K Preset 3500K

9FS = 90 CRI Selectable 3000 / 3500 / 4000K Preset 3500K

827 = 80CRI/ 2700K830 = 80CRI/ 3000K835 = 80CRI/ 3500K840 = 80CRI/ 4000K

927 = 90CRI/ 2700K930 = 90CRI/ 3000K935 = 90CRI/ 3500K940 = 90CRI/ 4000K

MW = matte white

MMS = matte metallic silver

BZ = dark bronze

PR4WW= wall wash kit, field installed

PR4MDWD= 4” reversible medium / wide lens -replacement part

OT450P = Oversize metal retrofit ring with 5.5” ID opening, 8” OD flange

Footnote:1 Not available in Chicago Plenum2 ULusListed U.S. only

ACCESSORIES

Halo Commercial PR4 – Retrofit KitDistributed Low Voltage Driver

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 14: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

14

LOW LUMEN MODULE1000lm / 1500lm / 2000lm

Halo Commercial PR4R – Retrofit Kit4-inch Selectable LED Downlight

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 15: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

15

HIGH LUMEN MODULE2000lm / 3000lm / 4000lm

Halo Commercial PR4R – Retrofit Kit4-inch Selectable LED Downlight

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 16: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

HOUSING PR4S FS12 D010 LED MODULE PR4M 12 MD 8FS MW

Housing Lumens (Nominal) Driver Finish LED Module Lumens (Nominal) Lens / Beam CRI / CCT Finish Accessory

PR4S = 4" Surface Cylinder

Field SelectableFS12 = selectable 1000 / 1500 / 2000 lumens, use with PR4M12* LED module

FS24 = selectable 2000 / 3000 / 4000 lumens, use with PR4M24* LED module

Fixed, Factory Set10 = 1000 lumens, use with PR4M12* LED module

15 = 1500 lumens, use with PR4M12* LED module

30 = 3000 lumens, use with PR4M24* LED module

D010 = 120 - 277V 50/60Hz 0 – 10V 1% -100% dimming

MW = matte white

MMS = matte metallic silver

BZ = dark bronze

PR4M = 4" LED module

12 = selectable 1000 / 1500 / 2000 lumens, Preset 2000lmUse with PR4SFS12*, PR4S10*, PR4S15* cylinders

24 = selectable 2000 / 3000 / 4000 lumens,Preset 4000lmUse with PR4SFS24*, PR4S30* cylinders

MD = medium / wide beam reversible lens. Factory set for medium. Tool-less turn-to-lock reversal changes from medium to wide

8FS = 80 CRI Selectable 3000 / 3500 /4000K Preset 3500K

9FS = 90 CRI Selectable 3000 / 3500 /4000K Preset 3500K

827 = 80CRI/ 2700K830 = 80CRI/ 3000K835 = 80CRI/ 3500K840 = 80CRI/ 4000K

927 = 90CRI/ 2700K930 = 90CRI/ 3000K935 = 90CRI/ 3500K940 = 90CRI/ 4000K

MW = matte white

MMS = matte metallic silver

BZ = dark bronze

PR4WW= wall wash kit, field installed

PR4MDWD= 4” reversible medium / wide lens -replacement part

ACCESSORIES

Halo Commercial PR4R – Surface Cylinder4-inch Selectable LED Cylinder

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 17: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

17

CYLINDER w/ High Lumen Module2000lm / 3000lm / 4000lm

CYLINDER w/ Low Lumen Module1000lm / 1500lm / 2000lm

Halo Commercial PR4R – Surface Cylinder4-inch Selectable LED Downlight Cylinder

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 18: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

18

ManufacturerNew

ConstructionRetrofit

Surface Cylinder

Selectable1000/2000/

3000 lumens

Selectable 2000/3000/

4000 lumens

Selectable CCT90 CRI option

1% Dimming

120V-277V

cULus /Wet Location

PR4

GE CurrentLRS-R4

Accy Plate 650/1000 10%

Green CreativeSelectFit

Accy Plate 550/750/1000 80CRI 5% & 10% ETL WetMaxLiteUniversal Commercial Accy Plate 750 only 80 CRI 120V Triac

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Halo Commercial PR4R4-inch Selectable LED Downlight

NO EQUALS TO PR4

Page 19: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

• UNV 120-277V, 0-10V dimming driver dims to 1%• Factory installed emergency options:

• 7W or 14W battery backup – new construction & Retrofit • Remote test switch

Electrical

• Frame: “boat-shaped” for new construction or remodel• Preinstalled “No Fuss” bars, and bar brackets also accept EMT• Remodel: remove bar brackets from boat-shaped frame to install from

below the ceiling

Frame

Mechanical

• Color temperature selection: 3000K / 3500K / 4000K in 80CRI or 90CRI• Lumen options:

• Low lumen range: 1000 / 1500 / 2000 lm• High lumen range: 2000 / 3000 / 4000 lm

SelectableColor

Lumens

• Factory installed connected lighting options:• LumaWatt Pro- Enlighted sensor - daylight, motion, heat, asset tracking • WaveLynx wireless tilemountsensor kit daylight, motion, RTLS option• DLVP – Low Voltage DC driver in distributed low voltage power system

Connected Lighting

Halo Commercial PR4 SeriesQuick Reference Specifications

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 20: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

• Self-flanged metal trim/module• Medium / Wide beam polymer reversable “flip” lens

• Medium beam position factory pre-set• Wide beam option by reversing “flip” lens

Reflector

Mechanical

Optical

• High quality paint finishes• Matte white, matte metallic silver, dark bronze

Reflector & Cylinder

Finishes

• Wall wash optional accessory louver & lens kitAccessory

• cULus listed/classified damp & wet listed in protected ceilings• Energy Star – certified light fixtures database• May be used for T24 Part 6 non-residential as a dimmable LED luminaire

Listings

Matte White

Matte Metallic Silver

Dark Bronze

Halo Commercial PR4 SeriesQuick Reference Specifications

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 21: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Dimmer / PIR Occupancy Sensor Occupancy or Vacancy 0-10V Dimmer 120/277V

Slide Dimmer0-10V Dimmer 120/277V

Decorator Dimmer0-10V Dimmer 120/277V

PIR Sensor Occupancy120/277VPIR Sensor Vacancy120/277V

PIR Sensor Occupancy120/277V

Ultrasonic Occupancy Sensor120/277V

Dual Technology Occupancy & Vacancy120/277V

Color KitsLt. Almond, White, IvoryBlack, White, Gray

Brochure: Wallbox Controls Line CardResources>Library>Literature>Controls

Greengate Wallbox Dimmers & Sensors• 0-10V dimmers • Sensor technology options• Passive Infrared• Ultrasonic• Dual Technology• Daylighting (-R/MV/DMV models) limit lighting when

room is lit by sunlight

Commercial – Lighting Controls Greengate Wallbox Controls

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 22: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Brochure: Greengate Room Controller SystemResources>Library>Literature>Controls

Greengate Room Controller• Three output relays • Three 0-10 VDC dimming outputs• Each 0-10V output supports up to 50

dimming drivers sourcing 2mA • 120/277V, 20A input• Wallstations, occ./vac. sensors, daylight

sensors, receptacle controllers• Connect via QuickConnect Class 2 cables

to room controller

Commercial Lighting Controls Greengate Room Controller

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 23: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

DLVP System• DLV factory installed driver• DLVP System low voltage power supply

• Order separately• Powers the HC6 low voltage driver• 300W or 600W power supply units• Note max wattage limit per run• Plenum rated enclosure• Addressable w/ accessory remotes• Dimming 1% to 100%

• Plenum rated pre-terminated cables• Order separately• Supply power & communications

Benefits• Simplified installation and configuration• Up to 40% lower labor install hours• Up to 20% lower installed system cost• Tile mount daylight and occupancy sensors

Brochure: Distributed Low Voltage Power SystemResources>Library>Literature>Connected Systems

Commercial Lighting Controls DLVP – Distributed Low Voltage Power

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 24: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

WaveLinx• Tile mount daylight & PIR motion sensor

and control unit• Optional Real Time Location Services

• Control unit 120-277VAC 3amp relay pack with 0-10V dimming control

• Control unit mounts to fixture junction box

Benefits• Reduces commissioning time 40%• Automatic code commissioning meets or

exceeds code requirements • Mobile app for building managers to easily

adjust settings

Factory Installed• WTA = WaveLinx factory kit (order with

the housing frame)

Field Installed Accessory Kit• WTA = WaveLinx field installed kit (order

separately)

Brochure: WaveLinxResources>Library>Literature>Connected Systems

Commercial Lighting Controls WaveLinx

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 25: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Wireless data

Brochure: LumaWatt ProResources>Library>Literature>Connected Systems

LumaWatt Pro - Enlighted • Tile mount sensor and control unit• Monitor real time occupancy, light levels,

temperatures and energy usage

Factory Installed• LWTPD1 = LumaWatt factory kit (order

with the housing frame)

Field Installed Accessory Kit• PORLWTPD1 = LumaWatt field installed

kit (order separately)

Commercial Lighting Controls LumaWatt Pro

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Page 26: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

Halo Commercial PR4 Series

26

Marketing Collateral Online • Specification sheets• Brochure• Instruction sheets• Dimming guide• IES files posted to webpages

Pricing & Availability• In-stock • Consult FLASH for up to date pricing and

availability

Overview Configuration Benchmarking Quick Reference Controls Pricing & Support

Halo Commercial Tools website• Training Guide Presentation• Specification sheets• Brochure• Instruction sheets• Dimming guide

Page 27: PR4 Sales Guide€¦ · •Flush ceiling installation to 4 _ round, 3-1/2 _ and 4 _ octagonal and square junction boxes •Listed for wet locations in protected ceilings •Integral

© 2019 Cooper Lighting Solutions. All rights reserved.