42
Powerwave ® Acoustic Cleaners for SCR Systems Jake Shelton GE Energy © 2004 by General Electric Company. All Rights Reserved.

Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Embed Size (px)

Citation preview

Page 1: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Powerwave® Acoustic Cleanersfor SCR Systems

Jake SheltonGE Energy

© 2004 by General Electric Company. All Rights Reserved.

Page 2: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Powerwave®

Acoustic Cleaners

Installations dating back to 1983

Page 3: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Acoustic Cleaners

Air operated horns that produce low frequency, high energy sound waves.

Page 4: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Acoustic CleanersThe sound waves cause particulate deposits to resonate and dislodge from structural and dust collection surfaces.

Page 5: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Pedestal

Titanium Diaphragm

3/4” Air Inlet

Cover Plate

1/4” Air Outlet

D Series Sound Generator

Page 6: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

PowerWave Air Requirements

> Air Pressure: ‒ 70 – 90 PSI‒ 4.83 – 6.21 bar

> Air Consumption:‒ 60 – 80 SCFM ‒ 19 – 38 l/s

Page 7: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

General Piping Arrangement

3/43/4””Solenoid ValveSolenoid Valve

3/43/4””Flex HoseFlex Hose

Air Header Air Header

Page 8: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

PowerWave® Acoustic Cleaners

Frequencies from 360 Hz to 75 Hz

ESP-75D-75DC-75D-230D-360D-Fluidizer

AH-10AH-15AH-25AG-20-BAcoustic Lance

Page 9: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Lower Frequency = Great Effective Cleaning Area> The wave length of an acoustic cleaner with a

fundamental frequency of 75 Hz is 3 times greater than the wave length emitted from an acoustic cleaner with a fundamental frequency of 230 Hz.

> An acoustic cleaner with a fundamental frequency of 75 Hz does not require as high of dB output to be effective in resonating fly ash deposits as an acoustic cleaner with a fundamental frequency of 230 Hz.

Page 10: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Model DC-75Fundamental Frequency -- 75 HzPWMF -- 107 Hz

110

129

146

126 126

143

130137

60708090

100110120130140150

50 Hz 63 Hz 80 Hz 100 Hz 125 Hz 160 Hz 200 Hz 250 Hz

50 Hz63 Hz80 Hz100 Hz125 Hz160 Hz200 Hz250 Hz

Page 11: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Effective Cleaning Area

1 m 2 m 4 m 6 m 8 m 16 m

Model D-230

4’9”Wave Length

(1 .44 m)

3’Cleaning P

attern

No Longer Effective

230 Hz

147 dB 141dB 135dB 132 dB 129dB 123 dB

Page 12: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Effective Cleaning Area

1 M 2 M 4 M 8 M 12 M 16 M (39’)

Model D-75

14’9”Wave Length

(4.49 m)

11’ Clean ing

Pa tt er n

75 Hz

147 dB 141dB 135dB 129 dB 126dB 123 dB

Page 13: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Acoustic Cleaner Applications onBoilers

> Air Preheaters> Baghouses> Ductwork> Economizers> Fans> Precipitators> SCR Reactors

Page 14: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Advantages of Using the Model D-75Low Initial Investment:> A Model D-75 cost less than 25% of the

cost of a rake style steam sootblower

Page 15: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Advantages of Using the Model D-75Low Installation Cost:> The majority of the installation cost for the

Model D-75 is running a 2” or less air line to each acoustic cleaner as compared to running high pressure steam lines to each sootblower.

Page 16: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Rake Style Steam Sootblowers

Insulated Steam Lines

OutsideSupport

Steel

BlockedWalkway

Page 17: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Model D-75s

1” Air LineNo WalkwayObstructions

Page 18: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Advantages of Using the Model D-75s:No Damage to the Catalyst

Lab & Field TestedThe acoustic energy emittedby the Model D-75 does not harm catalyst.

Page 19: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Advantages of Using the Model D-75sLow Operational Cost> The cost of operating one (1) acoustic

cleaner that is sounded for 10 seconds every 10 minutes is $0.47 per day.

> This is based on the US industry standard of $0.25 per 1000 cubic feet of air.

Page 20: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Advantages of Using the Model D-75sLow Maintenance Cost> The Model D-75 has only 1 moving part, a

titanium diaphragm. > The diaphragm has a life expectancy of

over 5 years.

Page 21: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

SCR Installation Experience

• Installations on more than 100 SCR Reactors following coal-fired boilers.

• Installations on more than 20 SCR Reactors designed by Babcock Power.

• The first installation on a SCR Reactor designed by Babcock Power took place in 2001. Since that time, all of the SCR Reactors designed by Babcock Power have used GE Energy’s acoustic cleaners as the catalyst cleaning system.

• Installations on numerous SCR Reactors fitted with plate style catalyst as supplied by Hitachi.

Page 22: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

SCR Installation ExperienceGE Energy has installations on SCR reactors

in low dust and high dust arrangements.

Low Dust Reactor High Dust Reactor

Page 23: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

SCR Installation ExperienceNumerous installations on SCR reactors

using a variety of catalyst designs

Honeycomb Plate Corrugated

Page 24: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Steam Sootblower

Model D-75

PG&E Generating Co.Indiantown Station

Duke EnergyBelews Creek Steam Station

MirantBirchwood Power Facility

and Others

Acoustic Cleanersvs. Sootblowers

Page 25: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Model DC-75

Frequency: 75 HzSound Pressure Level: 147 dBLength: 94 3/4 inchesMouth of Bell: 15 1/2 inches

Page 26: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

React or W

all

Lagging Wall

I nsulat ion

Catalyst

Model DC-75Tube Mount

Page 27: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM
Page 28: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

React or W

all

L ag g ing W

a ll

Air Line

1450 mm

Model DC-75Tube Mount

Pressure Pulse Sensor

Page 29: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

React or W

all

L ag g ing W

a ll

Air Line

Pressure Pulse Sensor

762 mm

710 mmModel DC-75Insertion Mount

Page 30: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Air Header

Isolation Valve

¾” Solenoid Valve

Flex Hose

Model D-75

Page 31: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Solenoid Valve Location

Easy Access Difficult Access

Page 32: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Powerwave ThermalWraps

Removable Insulating Blankets

Insulated Model D-75Insulated Model DC-75

Page 33: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Model D-75s that have been insulated by the plant.

Page 34: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Ambient Noise

Continuous Noise Level -- 72.2 dBAcoustic Cleaner Sounding – 88.6 dB

Page 35: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Acoustic Enclosures

A properly designed acoustic enclosure can reducethe ambient noise by as much as 10 dB.

Page 36: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Model D-75s beinginstalled on a SCR Reactor.

Installation Completed -The Model D-75s have

been covered with Acoustic Enclosures.

Page 37: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

What it does…

Acoustic Cleaner Verification System

The Acoustic Cleaner Verification Sensor monitors the pressure inside the horn. When the horn operates, the device senses the pressure waves as they travel down the bell sections, and triggers the output when the pressure waves reach a preset level. The Acoustic Cleaner Verification Sensor detects only the rapidly changing pressure caused by the sound pressure waves, so normal process pressure changes do not trigger the device.

Page 38: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Acoustic Cleaner Verification System

Pres

sure

Time

Output Active Output Active

ProcessPressure

Sound PressureWaves

Change inProcess Pressure

Page 39: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Specifications…

Acoustic Cleaner Verification System

Temperature Range -25°C to 85°C (-77°F to 185°F)

Power Supply 24 VDC ± 10%Output 24 VDC @ 3A *Sensor Port ¼” NPTStatic Pressure Range -75” H2O to 75” H2O

* Output current may be limited by external power supply.

Page 40: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Horn Verification System

Page 41: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

System Wiring

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn

Horn Verification Sensor24 VDC Signal

24 VDC Power

Horn Controller and/or

Annunciator By Customer or GE

24 VDC Power Supply By

Customer or GE

Page 42: Powerwave for SCR - WPCAwpca.info/pdf/presentations/3) Acoustic Cleaners for SCR Systems.pdf · Powerwave for SCR Author: GE Energy Created Date: 5/26/2005 1:47:16 PM

Any questions...

The End