Upload
joy-kerry-richardson
View
216
Download
0
Embed Size (px)
Citation preview
Powerpoint Templates
Page 1Powerpoint Templates
Android Multi-Meter (AMM)
Senior Design I
Final Presentation
Powerpoint Templates
Page 2
AMM Team Members
Team LeaderElectrical Engineer
• Design• Hardware• Analog Readings
Computer Engineer
• Website• App Programming• PIC Programming
Adviser: Dr. Sherif Abdelwahed
Chris Parker
Daniel Hosler
Justin Taylor
Computer Engineer
• Website• App Programming• PIC Programming
Powerpoint Templates
Page 3
Outline
• Problem• Solution•System Overview• Constraints
• Technical• Practical
• Prototype• Evaluation• Future Work•Questions
Powerpoint Templates
Page 4
Section 1
Problemand
Solution
Powerpoint Templates
Page 5
Problem
Most multimeters do not give you the ability of remote viewing. None of these multimeters enable Android devices as the screen.
Our market is users with Android devices with a job or hobby that involves electronics.
Powerpoint Templates
Page 6
Solution
The AMM will allow users to take electrical readings from a distance that may either be more convenient or safer.
The AMM will take readings in several ranges of:
- Voltage - Capacitance
- Resistance
- Current
Powerpoint Templates
Page 7
What is the AMM?
• The user will use leads to take a reading of the electrical system of interest
• The reading will be read into the microprocessor and sent to the wireless module
• The wireless module will then send the information to the Android application which displays the result on the phone
AMM
Powerpoint Templates
Page 8
System Overview
Power Supply
BluetoothRN-41
Leads
Pic24
AndroidApplication
Max134
Powerpoint Templates
Page 9
Section 2
Technical and PracticalConstraints
Powerpoint Templates
Page 10
Technical Constraints
Name Description
Measurement
AC Voltage, AC Current, DC Voltage, DC Current, Resistance, Diode Check, Capacitance with ±2% of Range and ± 2 Counts
Wireless Comm. 20’ minimum range
Battery Life 10 hours
Data LoggingMaximum Sample Rate: 20 Hz On Board Memory: 32kB Flash
DisplayDisplay data with needed prefix and decimal places
Powerpoint Templates
Page 11
Practical Constraints
The AMM application software will be regularly updated
• Compatible for future devices
• Longevity of usefulness
• Fix bugs
• Add functionality
Sustainability and Maintenance
Powerpoint Templates
Page 12
Practical Constraints
Economic and Cost
The AMM will use cheaper hardware components than competitors.
• The AMM will rely on the users personal display and not provide its own
• The AMM will use an Android application that is less expensive for development
Powerpoint Templates
Page 13
Prototype
Powerpoint Templates
Page 14
Prototype
MAX134 DMM Chip
Powerpoint Templates
Page 15
Prototype
RMS to DCConverter
Powerpoint Templates
Page 16
Prototype
PIC24HJ128GP502μController
Powerpoint Templates
Page 17
Prototype
RN-41 Blue-Tooth Module
Powerpoint Templates
Page 18
Prototype
Capacitance Test Circuit
Powerpoint Templates
Page 19
Evaluation
Powerpoint Templates
Page 20
Evaluation
Software
Powerpoint Templates
Page 21
Coding
Writing to the MAX registers
Powerpoint Templates
Page 22
Coding
Reading to the MAX registers
Powerpoint Templates
Page 23
Testing
Reading from the MAX 134
Powerpoint Templates
Page 24
Testing
Transmitting MAX 134 Data
Powerpoint Templates
Page 25
Testing
Debugging with RealTerm
Powerpoint Templates
Page 26
Software
Android Application
Powerpoint Templates
Page 27
Software
Android Application
Powerpoint Templates
Page 28
Testing
Sending a Command
Powerpoint Templates
Page 29
Evaluation
Hardware
Powerpoint Templates
Page 30
DC Voltage
DC Voltage Test Circuit
Powerpoint Templates
Page 31
DC Voltage
DC Voltage Test Data
Range Error0.4000V 100.5 mV 100.1 mV -0.4%0.4000V -115.5 mV -114.5 mV -0.9%4.000V 1.000 V 0.994 V -0.6%4.000V -1.000 V -1.013 V 1.3%40.00V 10.03 V 10.11 V 0.8%40.00V -10.03 V -9.98 V -0.5%300.0V 124.3 V 126.1 V 1.4%300.0V -124.3 V -124.1 V -0.2%
Expected Value Measured Value
Powerpoint Templates
Page 32
DC Current
DC Current Test Circuit
Powerpoint Templates
Page 33
DC Current
DC Current Test Data
Range Error1.000A 204.7 mA 204.3 mA -0.20%
Expected Value Measured Value
Powerpoint Templates
Page 34
AC Voltage
AC Voltage Test Circuit
Powerpoint Templates
Page 35
AC Voltage
AC Voltage Test Data
Range Error0.4000V 211.6 mV 86.7 mV -59.0%4.000V 2.824 V 2.58 V -8.6%40.00V 20.25 V 20.4 V 0.7%300.0V 149.6 V 149.9 V 0.2%
Expected Value Measured Value
Powerpoint Templates
Page 36
AC Current
AC Current Test Circuit
Powerpoint Templates
Page 37
AC Current
AC Current Test Data
Range Error1.000A 190.1 mA 182 mA -4.26%
Expected Value Measured Value
Powerpoint Templates
Page 38
Resistance
Resistance Test Circuit
Powerpoint Templates
Page 39
Resistance
Resistance Test Data
Range Error400.0Ω 100.0 Ω 101.1 Ω 1.10%4.000kΩ 0.997 kΩ 0.988 kΩ -0.90%40.00kΩ 10.03 kΩ 9.88 kΩ -1.50%400.0kΩ 100.6 kΩ 100.8 kΩ 0.20%4.000MΩ 1.019 MΩ 1.015 MΩ -0.39%
Expected Value Measured Value
Powerpoint Templates
Page 40
Capacitance
Capacitance Test Circuit
Powerpoint Templates
Page 41
Capacitance
Capacitance Test Data
Error
47.7 µF 47.6 µF -0.21%
Expected Value Measured Value
Powerpoint Templates
Page 42
Range
Sustained Connection Range
60 Feet
Powerpoint Templates
Page 43
Battery
Battery Life
Normal Operation - 15 Hours
Idle Conditions - 35 Hours
Powerpoint Templates
Page 44
Future Work
• Correct AC measurement errors
• Improve capacitance resolution
• Implement auto range features
• Final PCB Design
• Packaging
Powerpoint Templates
Page 45
Android Multi-Meter (AMM)
Questions?
• Senior Design I• Final Presentation