1
nbn Power Supply with Battery Backup Battery specification for Fibre to the Premises (FTTP) connections Identifying the nbn Power Supply with Battery Backup Location of battery Supply this page to your battery retailer. The specifications will help ensure the battery backup you purchase works with the nbn Power Supply with Battery Backup. Replacement of the battery Detailed battery replacement instructions are in the nbn Fibre User Guide that was supplied inside the nbn connection box enclosure or at nbn.com.au/battery For your own safety, never perform maintenance on your nbn Power Supply with Battery Backup (including disconnecting or replacing the battery) without first reading the detailed instructions in the nbn Fibre User Guide. For more information, including recycling instructions Phone 1800 687 626 Visit our website at nbn.com.au/battery Email [email protected] nbn connection box* *Also known as the Network Termination Device (NTD) nbn Power Supply with Battery Backup Battery Battery type: 12V 7.0-7.2Ah 6 cell VRLA Sealed Lead Acid Battery. Dimensions: • 94mm (H) x 151mm (W) x 65mm (D) (excl. terminals) • 100mm (H) x 151mm (W) x 65mm (D) (incl. terminals) (all tolerances +/- 1mm). Terminal type: Spade-type. Quick disconnect ‘F2’ 6.35mm (W) x 0.81mm (thickness). Terminal position: 8mm from the battery sides, 12-24mm from the battery end. Positive terminal positioned on the side depicted in the picture. 8mm 12-24mm © 2019 nbn co ltd. nbn and business nbn are trade marks of nbn co ltd | ABN 86 136 533 741. 1930162_FTTP

Power Supply with Battery Backup - Home | nbn · nbn™ Power Supply with Battery Backup Battery specification for Fibre to the Premises (FTTP) connections Identifying the nbn™

Embed Size (px)

Citation preview

Page 1: Power Supply with Battery Backup - Home | nbn · nbn™ Power Supply with Battery Backup Battery specification for Fibre to the Premises (FTTP) connections Identifying the nbn™

nbn™ Power Supplywith Battery BackupBattery specification for Fibre to the Premises (FTTP) connections

Identifying the nbn™ Power Supplywith Battery Backup

Location of battery

Supply this page to your battery retailer. The specifications will help ensure the battery backup you purchase works with the nbn™ Power Supply with Battery Backup.

Replacement of the battery Detailed battery replacement instructions are in the nbn™ Fibre User Guide that was supplied inside the nbn™ connection box enclosure or at nbn.com.au/battery

For your own safety, never perform maintenance on your nbn™ Power Supply with Battery Backup (including disconnecting or replacing the battery) without first reading the detailed instructions in the nbn™ Fibre User Guide.

For more information, including recycling instructionsPhone 1800 687 626 Visit our website at nbn.com.au/batteryEmail [email protected]

nbn™ connection box*

*Also known as the Network Termination Device (NTD)

nbn™ Power Supply with Battery Backup

Battery

Battery type:12V 7.0-7.2Ah 6 cell VRLA Sealed Lead Acid Battery.

Dimensions:• 94mm (H) x 151mm (W) x 65mm (D) (excl. terminals)• 100mm (H) x 151mm (W) x 65mm (D) (incl. terminals)(all tolerances +/- 1mm).

Terminal type:Spade-type. Quick disconnect ‘F2’ 6.35mm (W) x 0.81mm (thickness).

Terminal position: 8mm from the battery sides, 12-24mm from the battery end. Positive terminal positioned on the side depicted in the picture.

8mm12-24mm

© 2019 nbn co ltd. nbn and business nbn are trade marks of nbn co ltd | ABN 86 136 533 741. 1930162_FTTP