3
McLaren Applied Technologies McLaren Technology Centre Chertsey Road Woking Surrey GU21 4YH UK McLaren Applied Technologies Suite 115 Bostick Building 9801 West Kincey Avenue Huntersville NC 28078 USA Phone: +44 (0)1483 261400 Fax: +44 (0)1483 261402 [email protected] www.mclaren.com/mat Phone: +001 (704) 660 3181 Fax: +001 (704) 660 8829 © McLaren Applied Technologies 2014 Revision Date: 20 Jun 2005 Page 1 of 3 Power Supply Unit PSU-30V Product Summary

Power Supply Unit - McLaren Applied Technologies 30V/PSU 3… · • Supply current operating

  • Upload
    hakhanh

  • View
    224

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Power Supply Unit - McLaren Applied Technologies 30V/PSU 3… · • Supply current operating

McLaren Applied TechnologiesMcLaren Technology CentreChertsey RoadWokingSurreyGU21 4YHUK

McLaren Applied TechnologiesSuite 115

Bostick Building9801 West Kincey Avenue

HuntersvilleNC 28078

USA

Phone: +44 (0)1483 261400Fax: +44 (0)1483 261402

[email protected]/mat

Phone: +001 (704) 660 3181Fax: +001 (704) 660 8829

© McLaren Applied Technologies 2014 Revision Date: 20 Jun 2005 Page 1 of 3

Power Supply UnitPSU-30V

Product Summary

Page 2: Power Supply Unit - McLaren Applied Technologies 30V/PSU 3… · • Supply current operating

Power Supply UnitPSU-30V

McLaren Applied Technologies USA: McLaren Applied Technologies

Phone: +44 (0)1483 261400Fax: +44 (0)1483 261402

[email protected]/mat

Phone: +001 (704) 660 3181Fax: +001 (704) 660 8829

© McLaren Applied Technologies 2014 Revision Date: 20 Jun 2005 Page 2 of 3

The PSU-30V serves to boost and stabilise the car supply voltage from

14V nominal to 30V stabilised. This is to enable actuators to be driven from

a regulated 30V supply instead of the unregulated 14V car supply. For

solenoids, this allows faster actuation times.

Application

• Provision of a 30V stabilised voltage supply.

Electrical

• Supply voltage 8V to 16.7V at full rated power

• Supply current quiescent <100mA

• Supply current operating <12.6A at 14V at full rated power

• Supply voltage not to exceed 16.7V continuous (unit has reverse polarity protection and is protected against

momentary voltage spikes of either polarity greater than 16.7V)

• Output voltage 30V+0%, -7% at 1A load

• Output current 5A max

• Output impedance 100mohm typ

• Temperature coefficient ±5mV/°C typ

• Current trip providing some protection against momentary short-circuits or short-term overloads

• Output protected against transients

Electro Magnetic Compatibility

• Complies with the essential protection requirements of 89/336/EEC

Connection definition

• Integral, sealed, military-standard connector Lemo EHS.1F.308.XLC

• For PIN numbers please contact our technical consultancy department

Mechanical

• Case material magnesium alloy, chromate converted and painted with black epoxy

• Weight 160g

Environmental

• Splash resistant to standard motorsport fluids

• Temperature not to exceed 65°C at the centre of the top lid during operation – modest forced convection is advised

• Storage temperature -400C to +850C

• Vibration 100 to 1000Hz, all axes, 24 hours

Page 3: Power Supply Unit - McLaren Applied Technologies 30V/PSU 3… · • Supply current operating

Power Supply UnitPSU-30V

McLaren Applied Technologies USA: McLaren Applied Technologies

Phone: +44 (0)1483 261400Fax: +44 (0)1483 261402

[email protected]/mat

Phone: +001 (704) 660 3181Fax: +001 (704) 660 8829

© McLaren Applied Technologies 2014 Revision Date: 20 Jun 2005 Page 3 of 3