6
CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY 2018 Power Quality Solutions

Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

POWER QUALITY SOLUTIONSPower Quality issues can cause problems and damages to the equipments, while interrupting the production cycle in the most serious cases.

ICAR offers full Power Quality solutions:• Power Factor Correction• Active filters for harmonics• EMI Filters

ThyristorThyristorThyristorSwitched Switched Switched

C A PA C I TO R SY S T E M SFA S T C O M P E N S AT I O N

I N 0 , 1 5 S E C O N D

QUALITY MADE IN ITALY

COLT

ADV.IT

CT-ICAR-2

018-S

6-P

FC-2

EN

Icar Power Quality Solutionsby Ortea S.p.A. Via dei Chiosi, 2120873 Cavenago di Brianza MB - ItalyPhone +39 02 95.917.800

[email protected]

TECHNICAL FEATURES AND DIMENSIONS OF THIS CATALOGUE CAN BE CHANGED WITHOUT ICAR PRIOR NOTICE.ORTEA DECLINES ANY RESPONSIBILITY FOR DAMAGES TO HUMANS OR OBJECTS FROM WRONG SELECTION OR USE OF ICAR MADE PRODUCTS.

2018

Banks Range • FH20/S: with 180Hz detuned reactors and high energy density polypropylene film and 550V nominal voltage capacitors.

• FH30/S: with 135Hz detuned reactors and high energy density polypropylene film and 550V nominal voltage capacitors.

TECHNICAL CHARACTERISTICS Rated operational voltage Ue= 400-415VRated frequency 50HzMax current overload In (cabinet) 1.3xIn

Max current overload In (capacitors @40°C)

1.3xIn (continuo/continuous)2xIn (per 380s ogni 60 min./for 380s every 60 min.)3xIn (per 150s ogni 60 min /for 150s every 60 min.)4xIn (per 70s ogni 60 min /for 70s every 60 min.)5xIn (per 45s ogni 60 min /for 45s every 60 min.)

Max voltage overload Vn (cabinet) 1.1xUeMax voltage overload Vn (capacitors) 3xUN (for 1 min.)Insulating voltage 690VTemperature range (cabinet) -5/+40°CTemperature range (capacitors) -25/+55°CDischarge device on each bankUse indoorService continousCapacitors connection deltaOperation devices Thyristor swtchesTotal losses ~6W/kvarInner surface fi nish zinc passivationApplicable standards IEC 61439-1/2 IEC 61921 IEC 61642Capacitors standards IEC 60831-1/2

FH20/SPart

numberPOWERUe=415V

(kvar)

POWERUe=400V

(kvar)

STEPUe=400V

(kvar)

BANKSUe=400V

(kvar)

L.B. SWITCH

(A)

ICC(kA)

P.F.C.Controller

Dim IP4Xwxdxh

cm

IU7AFF310050786 107 100 20-2x40 20-2x40 250 17 8BGA 610x670x1760IU7AFF312050786 128 120 40-80 40-80 250 17 8BGA 610x670x1760IU7AFF314050786 150 140 20-40-80 20-40-80 400 25 8BGA 610x670x1760IU7AFF316050786 171 160 2x40-80 2x40-80 400 25 8BGA 610x670x1760IU7AFF320050786 214 200 40-2x80 40-2x80 630 25 8BGA 610x670x1760IU7AFF324050786 257 240 2x40-2x80 2x40-2x80 630 25 8BGA 610x670x1960IU7AFF328050786 300 280 40-3x80 40-3x80 630 25 8BGA 610x670x1960IU7AFF332050786 342 320 2x40-80-160 2x40-3x80 800 50 8BGA 610x670x2160IU7AFF336050786 385 360 40-2x80-160 40-4x80 800 50 8BGA 610x670x2160IU7AFF340050786 428 400 2x40-4x80 2x40-4x80 1250 50 8BGA 610x670x2360IU7AFF344050786 471 440 40-80-2x160 40-5x80 1250 50 8BGA 610x670x2360IU7AFF348050786 516 480 2x80-2x160 6x80 1250 50 8BGA 610x670x2360IU7AFF356050786 599 560 80-3x160 7x80 2x800 50 8BGA 1220x670x1960IU7AFF364050786 685 640 2x80-3x160 8x80 2x800 50 8BGA 1220x670x1960IU7AFF372050786 770 720 80-4x160 9x80 2x1250 50 8BGA 1220x670x2160IU7AFF380050786 856 800 2x80-4x160 10x80 2x1250 50 8BGA 1220x670x2160IU7AFF388050786 942 880 80-5x160 11x80 2x1250 50 8BGA 1220x670x2360IU7AFF396050786 1032 960 2x80-3x160-320 12x80 2x1250 50 8BGA 1220x670x2360

FH30/SIU7JFF260050872 65 60 20-40 20-40 250 17 8BGA 610x670x1960IU7JFF310050872 108 100 20-2x40 20-2x40 250 17 8BGA 610x670x1960IU7JFF314050872 151 140 20-3x40 20-3x40 400 25 8BGA 822x670x1960IU7JFF318050872 194 180 20-2x40-80 20-4x40 400 25 8BGA 610x670x2160IU7JFF322050872 237 220 20-5x40 20-5x40 630 25 8BGA 822x670x2360IU7JFF324050872 258 240 2x40-2x80 6x40 630 25 8BGA 822x670x2360IU7JFF328050872 301 280 40-3x80 7x40 2x400 25 8BGA 822x670x1960IU7JFF332050872 344 320 2x40-3x80 8x40 2x400 25 8BGA 822x670x1960IU7JFF336050872 388 360 40-4x80 9x40 2x630 25 8BGA 1432x777x2160IU7JFF340050872 431 400 2x40-4x80 10x40 2x630 25 8BGA 1432x777x2160IU7JFF344050872 474 440 40-5x80 11x40 2x630 25 8BGA 1432x777x2360IU7JFF348050872 517 480 2x40-3x80-160 12x40 2x630 25 8BGA 1432x777x2360

Also available the following series with bimetallized paper capacitors:TC10/S: with bimetallized paper and 400V nominal voltage capacitors.TC20/S: with bimetallized paper and 460V nominal voltage capacitors.FD25/S: with 180Hz detuned reactors and bimetallized paper and 460V nominal voltage capacitors.FD35/S: with 135Hz detuned reactors and bimetallized paper and 550V nominal voltage capacitors.

Power Quality Solutions

Power Quality Solutions

IP55 also available

Page 2: Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

Every time it’s necessary to compensate loads over short periods of time (example 60ms).Examples are steel companies, lifting apparatus (cranes, quay cranes, etc), cable makers (extruders, etc), welding machines, robots, compressors, skiing lift stations, LV industrial networks (chemical plants, paper mills, automotive suppliers), data centers.Every time is required a noiseless device like hotels, banks, offices, service infrastructures (telecommunications board, hospitals, malls).

Limits of the traditional contactor switched banks

• High inrush current and over voltages• Risk of over voltages due to the arc breaking• Longer reconnecting time: more than 30 sec• More demanding maintenance compared with

static switches.

In general there is a comprehensive PLANT EFFICIENCY; because power factor correction is fast, the power transformer and line design can be done considering only the actual load.Therefore longer working life and reliability of plant.Static switches allow unlimited operations.Steps switching is also done limiting transient phenomena that inside normal plants stresses the capacitors reducing their working life.

Electronic Fast Switches benefits

• High-speed reactive power availability (about 60ms to switch on total rating).

• No peak current on capacitors during steps operation.

• No peak voltage on capacitors during steps disconnection.

• Reduction of network disturbance such as voltage drop.

• No moving parts therefore reduced maintenance (i.e. no electro-magnetic contactors)

• Capacitors longer expected life Controller 8BGA with additional module STR4NO Technical characteristics

• Auxiliary supply voltage: 100÷440Vac• Frequency: 50Hz/60Hz• Voltage Measuring range: 100÷600Vac

(-15% / +10%)• Current Measuring range: 5A (1A selectable)• Current incoming range: from 25mA to 6A

(from 10mA to 1,2A)• Automatic phase sequence reading: yes• Compensation in cogeneration: yes• Burden: 9,5 VA• Output relay current: 5A – 250Vac• Cos φ range: from 0,5 ind to 0,5 cap• Step switching time: 1s÷1000s• Alarm relay: yes• Degree of protection: IP54• Working temperature range: from -20°C to 60°C• Storage temperature range: from -30°C to + 80°C• USB optic communication port (with COMUSB)• Temperature Control: from -30°C to +85°C• Standards compliance: IEC EN 61010-1; IEC/EN

61000-6-2;• IEC/EN 61000-6-3; UL508; CSA C22-2 n°14• Step output relays: 4 (expandible till) 8.

Communication functions

RPC 8BGA regulator is very powerful in terms of communication.The modules dedicated to these functions allow multiple solutions to remotely control the power factor system and all other variables measured, calculated or obtained fr om the instrument.

• COM232 isolated RS232 interface• COM485 RS485 opto-isolated• WEBETH Ethernet interface with webserver

function• COMPRO isolated Profi bus-DP interface• CX01 cable connection from the RPC 8BGA

optical port to the USB port of the computer for programming, downloading / uploading data, diagnostics etc..

• CX02 device to connect the optical port in the PRC

• 8BGA via WIFI: for programming, downloading / uploading data, diagnostics etc..

• CX03 antenna quad band GSM (800/900/1800

App POWER STUDIO

App available for WIFI interfacing with RPC 8BGA controller via Android tablet or smartphone.

Electronic Fast Switches general features

• Electronic Fast Switch speed : 20ms ON – 20ms OFF

• Capacitors Banks Switching speed: 0,12s ON – 0,12s OFF

• Continuous duty cycle• Built in over current protection: while the current

overcomes the threshold the switch opens until the current becomes normal

• Very small dimensions (220x262x120,5mm)• Made in Italy with all European components.• External signaling LED • Electronic Fast Switch doesn’t need any discharge

resistance.

Switching diagramContinuos duty cycle

When a real time cap bankis recommended

Real time 8BGAcontroller

Page 3: Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

Every time it’s necessary to compensate loads over short periods of time (example 60ms).Examples are steel companies, lifting apparatus (cranes, quay cranes, etc), cable makers (extruders, etc), welding machines, robots, compressors, skiing lift stations, LV industrial networks (chemical plants, paper mills, automotive suppliers), data centers.Every time is required a noiseless device like hotels, banks, offices, service infrastructures (telecommunications board, hospitals, malls).

Limits of the traditional contactor switched banks

• High inrush current and over voltages• Risk of over voltages due to the arc breaking• Longer reconnecting time: more than 30 sec• More demanding maintenance compared with

static switches.

In general there is a comprehensive PLANT EFFICIENCY; because power factor correction is fast, the power transformer and line design can be done considering only the actual load.Therefore longer working life and reliability of plant.Static switches allow unlimited operations.Steps switching is also done limiting transient phenomena that inside normal plants stresses the capacitors reducing their working life.

Electronic Fast Switches benefits

• High-speed reactive power availability (about 60ms to switch on total rating).

• No peak current on capacitors during steps operation.

• No peak voltage on capacitors during steps disconnection.

• Reduction of network disturbance such as voltage drop.

• No moving parts therefore reduced maintenance (i.e. no electro-magnetic contactors)

• Capacitors longer expected life Controller 8BGA with additional module STR4NO Technical characteristics

• Auxiliary supply voltage: 100÷440Vac• Frequency: 50Hz/60Hz• Voltage Measuring range: 100÷600Vac

(-15% / +10%)• Current Measuring range: 5A (1A selectable)• Current incoming range: from 25mA to 6A

(from 10mA to 1,2A)• Automatic phase sequence reading: yes• Compensation in cogeneration: yes• Burden: 9,5 VA• Output relay current: 5A – 250Vac• Cos φ range: from 0,5 ind to 0,5 cap• Step switching time: 1s÷1000s• Alarm relay: yes• Degree of protection: IP54• Working temperature range: from -20°C to 60°C• Storage temperature range: from -30°C to + 80°C• USB optic communication port (with COMUSB)• Temperature Control: from -30°C to +85°C• Standards compliance: IEC EN 61010-1; IEC/EN

61000-6-2;• IEC/EN 61000-6-3; UL508; CSA C22-2 n°14• Step output relays: 4 (expandible till) 8.

Communication functions

RPC 8BGA regulator is very powerful in terms of communication.The modules dedicated to these functions allow multiple solutions to remotely control the power factor system and all other variables measured, calculated or obtained fr om the instrument.

• COM232 isolated RS232 interface• COM485 RS485 opto-isolated• WEBETH Ethernet interface with webserver

function• COMPRO isolated Profi bus-DP interface• CX01 cable connection from the RPC 8BGA

optical port to the USB port of the computer for programming, downloading / uploading data, diagnostics etc..

• CX02 device to connect the optical port in the PRC

• 8BGA via WIFI: for programming, downloading / uploading data, diagnostics etc..

• CX03 antenna quad band GSM (800/900/1800

App POWER STUDIO

App available for WIFI interfacing with RPC 8BGA controller via Android tablet or smartphone.

Electronic Fast Switches general features

• Electronic Fast Switch speed : 20ms ON – 20ms OFF

• Capacitors Banks Switching speed: 0,12s ON – 0,12s OFF

• Continuous duty cycle• Built in over current protection: while the current

overcomes the threshold the switch opens until the current becomes normal

• Very small dimensions (220x262x120,5mm)• Made in Italy with all European components.• External signaling LED • Electronic Fast Switch doesn’t need any discharge

resistance.

Switching diagramContinuos duty cycle

When a real time cap bankis recommended

Real time 8BGAcontroller

Page 4: Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

Every time it’s necessary to compensate loads over short periods of time (example 60ms).Examples are steel companies, lifting apparatus (cranes, quay cranes, etc), cable makers (extruders, etc), welding machines, robots, compressors, skiing lift stations, LV industrial networks (chemical plants, paper mills, automotive suppliers), data centers.Every time is required a noiseless device like hotels, banks, offices, service infrastructures (telecommunications board, hospitals, malls).

Limits of the traditional contactor switched banks

• High inrush current and over voltages• Risk of over voltages due to the arc breaking• Longer reconnecting time: more than 30 sec• More demanding maintenance compared with

static switches.

In general there is a comprehensive PLANT EFFICIENCY; because power factor correction is fast, the power transformer and line design can be done considering only the actual load.Therefore longer working life and reliability of plant.Static switches allow unlimited operations.Steps switching is also done limiting transient phenomena that inside normal plants stresses the capacitors reducing their working life.

Electronic Fast Switches benefits

• High-speed reactive power availability (about 60ms to switch on total rating).

• No peak current on capacitors during steps operation.

• No peak voltage on capacitors during steps disconnection.

• Reduction of network disturbance such as voltage drop.

• No moving parts therefore reduced maintenance (i.e. no electro-magnetic contactors)

• Capacitors longer expected life Controller 8BGA with additional module STR4NO Technical characteristics

• Auxiliary supply voltage: 100÷440Vac• Frequency: 50Hz/60Hz• Voltage Measuring range: 100÷600Vac

(-15% / +10%)• Current Measuring range: 5A (1A selectable)• Current incoming range: from 25mA to 6A

(from 10mA to 1,2A)• Automatic phase sequence reading: yes• Compensation in cogeneration: yes• Burden: 9,5 VA• Output relay current: 5A – 250Vac• Cos φ range: from 0,5 ind to 0,5 cap• Step switching time: 1s÷1000s• Alarm relay: yes• Degree of protection: IP54• Working temperature range: from -20°C to 60°C• Storage temperature range: from -30°C to + 80°C• USB optic communication port (with COMUSB)• Temperature Control: from -30°C to +85°C• Standards compliance: IEC EN 61010-1; IEC/EN

61000-6-2;• IEC/EN 61000-6-3; UL508; CSA C22-2 n°14• Step output relays: 4 (expandible till) 8.

Communication functions

RPC 8BGA regulator is very powerful in terms of communication.The modules dedicated to these functions allow multiple solutions to remotely control the power factor system and all other variables measured, calculated or obtained fr om the instrument.

• COM232 isolated RS232 interface• COM485 RS485 opto-isolated• WEBETH Ethernet interface with webserver

function• COMPRO isolated Profi bus-DP interface• CX01 cable connection from the RPC 8BGA

optical port to the USB port of the computer for programming, downloading / uploading data, diagnostics etc..

• CX02 device to connect the optical port in the PRC

• 8BGA via WIFI: for programming, downloading / uploading data, diagnostics etc..

• CX03 antenna quad band GSM (800/900/1800

App POWER STUDIO

App available for WIFI interfacing with RPC 8BGA controller via Android tablet or smartphone.

Electronic Fast Switches general features

• Electronic Fast Switch speed : 20ms ON – 20ms OFF

• Capacitors Banks Switching speed: 0,12s ON – 0,12s OFF

• Continuous duty cycle• Built in over current protection: while the current

overcomes the threshold the switch opens until the current becomes normal

• Very small dimensions (220x262x120,5mm)• Made in Italy with all European components.• External signaling LED • Electronic Fast Switch doesn’t need any discharge

resistance.

Switching diagramContinuos duty cycle

When a real time cap bankis recommended

Real time 8BGAcontroller

Page 5: Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

POWER QUALITY SOLUTIONSPower Quality issues can cause problems and damages to the equipments, while interrupting the production cycle in the most serious cases.

ICAR offers full Power Quality solutions:• Power Factor Correction• Active filters for harmonics• EMI Filters

C A PA C I TO R SY S T E M SFA S T C O M P E N S AT I O N

I N 0 , 1 5 S E C O N D

QUALITY MADE IN ITALY

COLT

ADV.IT

CT-ICAR-2

018-S

6-P

FC-2

EN

Icar Power Quality Solutionsby Ortea S.p.A. Via dei Chiosi, 2120873 Cavenago di Brianza MB - ItalyPhone +39 02 95.917.800

[email protected]

TECHNICAL FEATURES AND DIMENSIONS OF THIS CATALOGUE CAN BE CHANGED WITHOUT ICAR PRIOR NOTICE.ORTEA DECLINES ANY RESPONSIBILITY FOR DAMAGES TO HUMANS OR OBJECTS FROM WRONG SELECTION OR USE OF ICAR MADE PRODUCTS.

2018

Banks Range • FH20/S: with 180Hz detuned reactors and high energy density polypropylene film and 550V nominal voltage capacitors.

• FH30/S: with 135Hz detuned reactors and high energy density polypropylene film and 550V nominal voltage capacitors.

TECHNICAL CHARACTERISTICS Rated operational voltage Ue= 400-415VRated frequency 50HzMax current overload In (cabinet) 1.3xIn

Max current overload In (capacitors @40°C)

1.3xIn (continuo/continuous)2xIn (per 380s ogni 60 min./for 380s every 60 min.)3xIn (per 150s ogni 60 min /for 150s every 60 min.)4xIn (per 70s ogni 60 min /for 70s every 60 min.)5xIn (per 45s ogni 60 min /for 45s every 60 min.)

Max voltage overload Vn (cabinet) 1.1xUeMax voltage overload Vn (capacitors) 3xUN (for 1 min.)Insulating voltage 690VTemperature range (cabinet) -5/+40°CTemperature range (capacitors) -25/+55°CDischarge device on each bankUse indoorService continousCapacitors connection deltaOperation devices Thyristor swtchesTotal losses ~6W/kvarInner surface fi nish zinc passivationApplicable standards IEC 61439-1/2 IEC 61921 IEC 61642Capacitors standards IEC 60831-1/2

FH20/SPart

numberPOWERUe=415V

(kvar)

POWERUe=400V

(kvar)

STEPUe=400V

(kvar)

BANKSUe=400V

(kvar)

L.B. SWITCH

(A)

ICC(kA)

P.F.C.Controller

Dim IP4Xwxdxh

cm

IU7AFF310050786 107 100 20-2x40 20-2x40 250 17 8BGA 610x670x1760IU7AFF312050786 128 120 40-80 40-80 250 17 8BGA 610x670x1760IU7AFF314050786 150 140 20-40-80 20-40-80 400 25 8BGA 610x670x1760IU7AFF316050786 171 160 2x40-80 2x40-80 400 25 8BGA 610x670x1760IU7AFF320050786 214 200 40-2x80 40-2x80 630 25 8BGA 610x670x1760IU7AFF324050786 257 240 2x40-2x80 2x40-2x80 630 25 8BGA 610x670x1960IU7AFF328050786 300 280 40-3x80 40-3x80 630 25 8BGA 610x670x1960IU7AFF332050786 342 320 2x40-80-160 2x40-3x80 800 50 8BGA 610x670x2160IU7AFF336050786 385 360 40-2x80-160 40-4x80 800 50 8BGA 610x670x2160IU7AFF340050786 428 400 2x40-4x80 2x40-4x80 1250 50 8BGA 610x670x2360IU7AFF344050786 471 440 40-80-2x160 40-5x80 1250 50 8BGA 610x670x2360IU7AFF348050786 516 480 2x80-2x160 6x80 1250 50 8BGA 610x670x2360IU7AFF356050786 599 560 80-3x160 7x80 2x800 50 8BGA 1220x670x1960IU7AFF364050786 685 640 2x80-3x160 8x80 2x800 50 8BGA 1220x670x1960IU7AFF372050786 770 720 80-4x160 9x80 2x1250 50 8BGA 1220x670x2160IU7AFF380050786 856 800 2x80-4x160 10x80 2x1250 50 8BGA 1220x670x2160IU7AFF388050786 942 880 80-5x160 11x80 2x1250 50 8BGA 1220x670x2360IU7AFF396050786 1032 960 2x80-3x160-320 12x80 2x1250 50 8BGA 1220x670x2360

FH30/SIU7JFF260050872 65 60 20-40 20-40 250 17 8BGA 610x670x1960IU7JFF310050872 108 100 20-2x40 20-2x40 250 17 8BGA 610x670x1960IU7JFF314050872 151 140 20-3x40 20-3x40 400 25 8BGA 822x670x1960IU7JFF318050872 194 180 20-2x40-80 20-4x40 400 25 8BGA 610x670x2160IU7JFF322050872 237 220 20-5x40 20-5x40 630 25 8BGA 822x670x2360IU7JFF324050872 258 240 2x40-2x80 6x40 630 25 8BGA 822x670x2360IU7JFF328050872 301 280 40-3x80 7x40 2x400 25 8BGA 822x670x1960IU7JFF332050872 344 320 2x40-3x80 8x40 2x400 25 8BGA 822x670x1960IU7JFF336050872 388 360 40-4x80 9x40 2x630 25 8BGA 1432x777x2160IU7JFF340050872 431 400 2x40-4x80 10x40 2x630 25 8BGA 1432x777x2160IU7JFF344050872 474 440 40-5x80 11x40 2x630 25 8BGA 1432x777x2360IU7JFF348050872 517 480 2x40-3x80-160 12x40 2x630 25 8BGA 1432x777x2360

Also available the following series with bimetallized paper capacitors:TC10/S: with bimetallized paper and 400V nominal voltage capacitors.TC20/S: with bimetallized paper and 460V nominal voltage capacitors.FD25/S: with 180Hz detuned reactors and bimetallized paper and 460V nominal voltage capacitors.FD35/S: with 135Hz detuned reactors and bimetallized paper and 550V nominal voltage capacitors.

Power Quality Solutions

Power Quality Solutions

IP55 also available

Page 6: Power Quality Solutions - ICAR...Thyristor Switched CAPACITOR SYSTEMS FAST COMPENSATION IN 0,15 SECOND QUALITY MADE IN ITALY COLTADV.IT CT-ICAR-2018-S6-PFC-2EN Icar Power Quality Solutions

POWER QUALITY SOLUTIONSPower Quality issues can cause problems and damages to the equipments, while interrupting the production cycle in the most serious cases.

ICAR offers full Power Quality solutions:• Power Factor Correction• Active filters for harmonics• EMI Filters

C A PA C I TO R SY S T E M SFA S T C O M P E N S AT I O N

I N 0 , 1 5 S E C O N D

QUALITY MADE IN ITALY

COLT

ADV.IT

CT-ICAR-2

018-S

6-P

FC-2

EN

Icar Power Quality Solutionsby Ortea S.p.A. Via dei Chiosi, 2120873 Cavenago di Brianza MB - ItalyPhone +39 02 95.917.800

[email protected]

TECHNICAL FEATURES AND DIMENSIONS OF THIS CATALOGUE CAN BE CHANGED WITHOUT ICAR PRIOR NOTICE.ORTEA DECLINES ANY RESPONSIBILITY FOR DAMAGES TO HUMANS OR OBJECTS FROM WRONG SELECTION OR USE OF ICAR MADE PRODUCTS.

2018

Banks Range • FH20/S: with 180Hz detuned reactors and high energy density polypropylene film and 550V nominal voltage capacitors.

• FH30/S: with 135Hz detuned reactors and high energy density polypropylene film and 550V nominal voltage capacitors.

TECHNICAL CHARACTERISTICS Rated operational voltage Ue= 400-415VRated frequency 50HzMax current overload In (cabinet) 1.3xIn

Max current overload In (capacitors @40°C)

1.3xIn (continuo/continuous)2xIn (per 380s ogni 60 min./for 380s every 60 min.)3xIn (per 150s ogni 60 min /for 150s every 60 min.)4xIn (per 70s ogni 60 min /for 70s every 60 min.)5xIn (per 45s ogni 60 min /for 45s every 60 min.)

Max voltage overload Vn (cabinet) 1.1xUeMax voltage overload Vn (capacitors) 3xUN (for 1 min.)Insulating voltage 690VTemperature range (cabinet) -5/+40°CTemperature range (capacitors) -25/+55°CDischarge device on each bankUse indoorService continousCapacitors connection deltaOperation devices Thyristor swtchesTotal losses ~6W/kvarInner surface fi nish zinc passivationApplicable standards IEC 61439-1/2 IEC 61921 IEC 61642Capacitors standards IEC 60831-1/2

FH20/SPart

numberPOWERUe=415V

(kvar)

POWERUe=400V

(kvar)

STEPUe=400V

(kvar)

BANKSUe=400V

(kvar)

L.B. SWITCH

(A)

ICC(kA)

P.F.C.Controller

Dim IP4Xwxdxh

cm

IU7AFF310050786 107 100 20-2x40 20-2x40 250 17 8BGA 610x670x1760IU7AFF312050786 128 120 40-80 40-80 250 17 8BGA 610x670x1760IU7AFF314050786 150 140 20-40-80 20-40-80 400 25 8BGA 610x670x1760IU7AFF316050786 171 160 2x40-80 2x40-80 400 25 8BGA 610x670x1760IU7AFF320050786 214 200 40-2x80 40-2x80 630 25 8BGA 610x670x1760IU7AFF324050786 257 240 2x40-2x80 2x40-2x80 630 25 8BGA 610x670x1960IU7AFF328050786 300 280 40-3x80 40-3x80 630 25 8BGA 610x670x1960IU7AFF332050786 342 320 2x40-80-160 2x40-3x80 800 50 8BGA 610x670x2160IU7AFF336050786 385 360 40-2x80-160 40-4x80 800 50 8BGA 610x670x2160IU7AFF340050786 428 400 2x40-4x80 2x40-4x80 1250 50 8BGA 610x670x2360IU7AFF344050786 471 440 40-80-2x160 40-5x80 1250 50 8BGA 610x670x2360IU7AFF348050786 516 480 2x80-2x160 6x80 1250 50 8BGA 610x670x2360IU7AFF356050786 599 560 80-3x160 7x80 2x800 50 8BGA 1220x670x1960IU7AFF364050786 685 640 2x80-3x160 8x80 2x800 50 8BGA 1220x670x1960IU7AFF372050786 770 720 80-4x160 9x80 2x1250 50 8BGA 1220x670x2160IU7AFF380050786 856 800 2x80-4x160 10x80 2x1250 50 8BGA 1220x670x2160IU7AFF388050786 942 880 80-5x160 11x80 2x1250 50 8BGA 1220x670x2360IU7AFF396050786 1032 960 2x80-3x160-320 12x80 2x1250 50 8BGA 1220x670x2360

FH30/SIU7JFF260050872 65 60 20-40 20-40 250 17 8BGA 610x670x1960IU7JFF310050872 108 100 20-2x40 20-2x40 250 17 8BGA 610x670x1960IU7JFF314050872 151 140 20-3x40 20-3x40 400 25 8BGA 822x670x1960IU7JFF318050872 194 180 20-2x40-80 20-4x40 400 25 8BGA 610x670x2160IU7JFF322050872 237 220 20-5x40 20-5x40 630 25 8BGA 822x670x2360IU7JFF324050872 258 240 2x40-2x80 6x40 630 25 8BGA 822x670x2360IU7JFF328050872 301 280 40-3x80 7x40 2x400 25 8BGA 822x670x1960IU7JFF332050872 344 320 2x40-3x80 8x40 2x400 25 8BGA 822x670x1960IU7JFF336050872 388 360 40-4x80 9x40 2x630 25 8BGA 1432x777x2160IU7JFF340050872 431 400 2x40-4x80 10x40 2x630 25 8BGA 1432x777x2160IU7JFF344050872 474 440 40-5x80 11x40 2x630 25 8BGA 1432x777x2360IU7JFF348050872 517 480 2x40-3x80-160 12x40 2x630 25 8BGA 1432x777x2360

Also available the following series with bimetallized paper capacitors:TC10/S: with bimetallized paper and 400V nominal voltage capacitors.TC20/S: with bimetallized paper and 460V nominal voltage capacitors.FD25/S: with 180Hz detuned reactors and bimetallized paper and 460V nominal voltage capacitors.FD35/S: with 135Hz detuned reactors and bimetallized paper and 550V nominal voltage capacitors.

Power Quality Solutions

Power Quality Solutions

IP55 also available