30
1 Setting Evaporative Emission Standards for Off Highway Recreational Vehicles (OHRV) March 23, 2006

Power Point - 258K

Embed Size (px)

Citation preview

Page 1: Power Point - 258K

1

Setting Evaporative Emission Standards for Off Highway

Recreational Vehicles (OHRV)

March 23, 2006

Page 2: Power Point - 258K

2

Presentation Outline

1. U.S. EPA standards2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 3: Power Point - 258K

3

U.S. EPA Standards

• Fuel hose permeation standard of 15 g/m2/day– Test temperature of 23 C

• Fuel tank permeation standard of 1.5 g/m2/day– Test temperature of 28 C

Page 4: Power Point - 258K

4

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 5: Power Point - 258K

5

Limitations of U.S. EPA Regulation

• Current technology supports lowering permeation standards

• U.S. EPA regulation does not control vented emissions from the fuel tank

• U.S. EPA regulation does not control carburetor and connector emissions

Page 6: Power Point - 258K

6

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 7: Power Point - 258K

7

California Emissions Inventory(Current Estimate)

Vehicle Type PopulationTotal Evaporative Emissions

(annual average, tons/day)

All Terrain Vehicles 14865 1.0

Off-Road Motorcycles 157706 15.9

Snowmobiles 19739 0.3

Totals 192310 17.2

Page 8: Power Point - 258K

8

California Emissions Inventory Verification

• Vehicle population will be evaluated

– DMV data suggests the population is far higher

Page 9: Power Point - 258K

9

California Emissions Inventory Verification

• Running loss emissions will be verified

– Emissions appear high, therefore the emission factor, activity and methodology used to obtain this data will be reviewed

Page 10: Power Point - 258K

10

California Emissions Inventory Verification

• Representative equipment will be used to generate any needed emissions factors

Page 11: Power Point - 258K

11

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 12: Power Point - 258K

12

Testing Results for OHRV Tested by Automotive Testing Laboratories (ATL)

• ATL tested evaporative emissions for 4 off-road motorcycles and 4 ATVs

• Diurnal and hot soak emissions were measured for each vehicle

• Refueling and running loss emission were measured for select vehicles

• Data was generated using:– Summer fuel (7 RVP)– 65-105 F temperature profile– Tank Filled to 50%

Page 13: Power Point - 258K

13

Testing Results for OHRV Tested by ATL (Continued)

Dirt bikesFuel TankVolume

(gal)

Hot Soak Losses(grams per 3 hour soak)

Diurnal Losses(grams/day)

Running Loss(grams/mile)

Refueling Losses(grams/gal)

82 Honda XR200R 4cyc 2.40 3.96 8.36 0.88 

00 Kawasaki KX250 2cyc 2.20 1.80 8.29  2.51

84 Suzuki RM125 2cyc 2.00 4.49 6.81   

01Yamaha WR250F 4cyc 3.20 9.70 18.57 1.27 

Average for Dirt Bikes 2.45 4.99 10.511.08   

ATVs          

83 Honda FL250 (Odyssey) 2cyc

3.00 2.24 16.98   

01 Yamaha YFZ350N-W (Banshee) 2cyc

3.20 2.64 15.79 1.28 

01 Suzuki LT-F250 (Quadrunner) 4cyc

3.20 2.16 5.36 0.08 2.95

88 Kawasaki KLF220 (Bayou) 4cyc

2.60 4.96 15.40 0.9 

Average for ATVs 3.00 3.00 13.380.75   

Page 14: Power Point - 258K

14

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 15: Power Point - 258K

15

Emissions Source Breakdown

• Emissions by component are calculated from:– ATL data– Vented emissions calculated using

• Reddy Equation• Summer fuel (7 RVP)• 65-105 F temperature profile• Tank filled to 50%

– Permeation emission calculated using:• 1.5 feet of ¼ inch fuel line • A cubic fuel tank• Permeation equal to the standards• Uncontrolled permeation rates of:

– 12 g/m2/day for fuel tanks– 100 g/m2/day for fuel hose

Page 16: Power Point - 258K

16

Breakdown of Uncontrolled Emissions Sources for Off-Road

MotorcyclesEmissions Sources for Off-Road Motorcycles

g/day% of Total Emissions

Permeation Emissions

From Fuel line0.919%

Carburetor and Other

Emissions3.3632%

Permeation Emissions from

Fuel Tank 3.1730%

Diurnal Tank Emissions

3.062529%

Page 17: Power Point - 258K

17

Breakdown of Uncontrolled Emissions Sources for ATVs

Emissions Sources for ATVsg/day

% of Total Emissions

Permeation Emissions

from Fuel Tank 3.6427%

Carburetor and Other

Emissions5.0838%

Diurnal Tank Emissions

3.7528%

Permeation Emissions

From Fuel line0.917%

Page 18: Power Point - 258K

18

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 19: Power Point - 258K

19

Need for ARB Regulation

• Significant additional reductions are needed for ozone attainment

• Permeation emissions can be controlled further

• Vented emissions can be controlled

• Carburetor and connector emissions can be controlled

Page 20: Power Point - 258K

20

Permeation Technology Advancements from SORE Allow

Lower ARB Standards

* Increase in test temp of 10 deg C leads to double the permeation

Company name Product Test FuelTest Results

(g/m^2/day)

Equivilent Results at 28 C for tanks and 23 C

for hoses *

EPA standard @ test temperature

(g/m2/day

Arkema Tank CE10 0.80 0.35 1.5 @28C

Custom Pak Tank California Cert. fuel 0.30 0.13 1.5 @28C

Kelch Tank California Cert. fuel 0.26 0.11 1.5 @28C

Avon Automotive Hose California Cert. fuel 3.94 1.71 15 @23C

Dana Hose Indolene 7.40 3.22 15 @23C

DTR industries Hose Indolene 3.20 1.39 15 @23C

Gates Hose California Cert. fuel 8.20 3.57 15 @23C

good year tire Hose CE10 12.32 5.36 15 @23C

Mold-Ex Hose California Cert. fuel 4.63 2.02 15 @23C

Parker Hose CE10 12.60 5.48 15 @23C

Parker (Model # II) Hose CE10 3.75 1.63 15 @23C

Teleflex Hose CE10 11.13 4.85 15 @23C

Page 21: Power Point - 258K

21

Need to Control Vented and Carburetor Emissions

• Vented emissions account for ~30% of total emissions

• Carburetor and fittings emissions account for another ~30% of total emissions

• Controlling these emission sources will result in substantial reductions

Page 22: Power Point - 258K

22

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 23: Power Point - 258K

23

Potential Control Technologies to be Evaluated

• Active and passively purged carbon canisters

• Low permeation fuel hoses

• Low permeation fuel tanks

• Fuel injection systems

Page 24: Power Point - 258K

24

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 25: Power Point - 258K

25

ARB and U.S. EPA Evaporative Emissions Control Comparison Graph

ARB assumptions:• fuel hose permeation of 5g/m^2/day• fuel tank Permeation of 0.5 g/m^2/day• 65% diurnal and running loss control without FI• 80% diurnal and running loss control with FI•All values based on current emissions inventory

Tons/ day Reduction by Vehicle Type and Agnecy

0.52

0.040.62

10.23

2.06

12.90

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Tons/day Reduction of Total Emissions for Off-roadMotorcycles

Tons/day Reduction of Total Emissions for ATVs

tons

/day

EPA rule

ARB rule without FI

ARB rule with FI

Page 26: Power Point - 258K

26

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 27: Power Point - 258K

27

Next Steps for Rule Development(Tentative)

• Emissions Inventory Development– Spring 2006 – Spring 2007

• Control Technology Evaluation– Summer 2006 – Summer 2007

• Development of Staff Proposal– Summer 2007 – 2008

• Board Hearing – 2008

Page 28: Power Point - 258K

28

Outline

1. U.S. EPA standards 2. Limitations of U.S. EPA standards3. California emissions inventory4. Existing test data5. Emissions source breakdown6. Need for ARB regulation7. Potential control technology8. ARB and U.S. EPA control comparison9. Next steps10. Comments and contact information

Page 29: Power Point - 258K

29

Comments?

Page 30: Power Point - 258K

30

ContactsMonitoring and Laboratory Division

(For Questions Concerning the Rule Development)

• Jim Watson– Manager, Engineering Development and Testing Section

• (916) 327-1282, [email protected]

• Pippin Mader– Project Lead, Engineering Development and Testing Section

• (916) 322-8930, [email protected]

Planning and Technical Support Division(For Questions Concerning the Emissions Inventory)

• David Chou– Manager, Off-Road Modeling and Assessment Section

• (626) 450-6136, [email protected]