power and auxiliary layout for 1 storey residence

Embed Size (px)

DESCRIPTION

a sample of power and auxiliary layout including the general notes for the electrical plans

Citation preview

Page 1: power and auxiliary layout for 1 storey residence

REG. NO :

TIN NO :

PTR. NO :

DATE :

ENGINEER

SHEET CONTENTSPROJECT & LOCATION OWNER

DRAWN:

ALL PLANS AND SPECIFICATIONS, AS INSTRUMENTS

OF SERVICE, ARE THE PROPERTY OF THE DESIGNER

AND CANNOT BE COPIED OR DUPLICATED IN PART OR

IN WHOLE WITHOUT WRITTEN PERMISSION,THIS MUST

HAVE TO BE RETURNED WHEN NO LONGER IN USE.

SHT NUMBER

E-101

REG. NO :

TIN NO :

PTR. NO :

DATE :

ENGINEER

SHEET CONTENTSPROJECT & LOCATION OWNER

DRAWN:

ALL PLANS AND SPECIFICATIONS, AS INSTRUMENTS

OF SERVICE, ARE THE PROPERTY OF THE DESIGNER

AND CANNOT BE COPIED OR DUPLICATED IN PART OR

IN WHOLE WITHOUT WRITTEN PERMISSION,THIS MUST

HAVE TO BE RETURNED WHEN NO LONGER IN USE.

SHT NUMBER

E-201

1.

ELECTRICAL ENGINEER.

GENERAL NOTES:

3.

2.

4.

6.

5.

7.

2

9.

8.

11.

10.

SHALL BE MADE ACCORDINGLY.ALL MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED SHALL BE NEW AND MUSTBE OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE INTENDED.

ALL 20-AMPERE CIRCUIT HOMERUNS TO PANELBOARDS OF MORE THAN 30 METERS IN LENGTH SHALL BE 5.5mm UNLESS OTHERWISE SPECIFIED

VERIFIED WITH THE ENGINEER/OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES

WHERE REQUIRED. MINIMUM SIZE FOR ALL CONDUITS SHALL BE 15mm INSIDE DIAMETER

FOR PERMANENT CONNECTION WITH CONCRETE WALLING OR BEAM.

TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF UTILITIES & OTHER TRADES.

COPPER AND THERMOPLASTIC INSULATED TYPE THWN/THHN UNLESS OTHERWISE INDICATED. THEMINIMUM SIZE FOR POWER AND LIGHTING SHALL BE 3.5mm².THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF INCOMING POWERFOR CONNECTION INCLUDING THE LOCATION OF METER CENTER.ALL PIPE SLEEVES SHALL BE PROVIDED WITH PROPER SUPPORT OR ANCHORAGE NECESSARY

ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND ALLNON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN ACCORDANCE

CONDUIT ROUTING SHOWN IS ESSENTIALLY DIAGRAMMATICAL. CONTRACTOR SHALL LAY OUT RUNS

ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE

ELECTRICAL METALLIC CONDUIT (EMT). FLEXIBLE METALLIC CONDUITS SHALL ALSO BE USED THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN INTERMEDIATE METALLIC CONDUIT (IMC)

ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITHTHESE PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATESTEDITION OF THE PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THELOCAL ENFORCING AUTHORITY, AND THE REQUIREMENTS OF THE LOCAL POWER. THEELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED

THE ELECTRIC SERVICE VOLTAGE SHALL BE SINGLE PHASE 3-WIRE WITH GROUND 230V 60HZ.

ELECTRICAL TRADE SIZE MINIMUM SIZE OF PULLBOX TO BE USED SHALL BE 150x150x100mm.

ALL CONDUITS AND RACEWAY PENETRATIONS THROUGH FIRE OR SMOKE RATED WALLS AND FLOORSSHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAME AND HOT

12.

GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC OF FIRE STOPSASTM-E-814. PROVIDE A UL LISTED THROUGH PENETRATION FIRE STOP SYSTEM NUMBERED PER ULFIRE RESISTANCE DIRECTORY.

ALL WIRES FOR INDOOR INSTALLATION SHALL BE

WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.

MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS: SWITCHES : 1,370MM ABOVE FLOOR FINISH RECEPTACLES : 300MM ABOVE FLOOR FINISH

: 170MM ABOVE COUNTER TOP PANEL BOARD : 1800MM ABOVE FLOOR FINISH

13.

CHANDELIER

BRANCH CIRCUIT HOMERUN

LEGEND

1-40w FLUORESCENT LAMP

4"Ø / 6"Ø PINLIGHT

LIGHTING FIXTURE

E.RANGE OUTLET

REFRIGERATOR OUTLET

WEATHERPROOF OUTLET

ABOVE COUNTER OUTLET

DUPLEX CONVENIENCE OUTLET

PP01

KWHM KILOWATT-HOUR METERM

PP,LP,PB

CABLE TV OUTLET

TELEPHONE OUTLET

LIGHTING LINE, CONCEALED ON CLNG.

ELECTRICAL SERVICE ENTRANCE

SINGLE POLE SWITCH2-GANG SWITCH

POWER LN., EMBEDDED ON SLAB/WALL

ACU OUTLET

S2bc / S2

Sa / S

PANEL BOARD

GENERAL NOTES

POWER & AUXILIARY LAYOUT

POWER AND AUXILIARY LAYOUT

LIGHT SWITCHES DETAIL

CONVENIENCE OUTLET DETAIL

SCALE: 1:100 MTS.

POWER & AUXILIARY LAYOUT

E-11

150

PA

NE

L

TEL

CATV

LPA1

LPA2

SCALE: 1:100 MTS.

POWER & AUXILIARY LAYOUT

E-11

150

S2

S2

S2

S1

S1

PA

NE

L

JUAN DE LA CRUZ

JBS 08/07/13

JUAN DE LA CRUZ

JBS 08/07/13

LPA3

DESIGNER

DESIGNER

SERVICEENTRANCE

METERREADING

2-50mm² THHN STRANDED WIRE BLACK1-5.5mm² COPPER STRANDEDWIRE WHITE32mmØ RIGID STEEL CONDUIT PIPE(RSCP)

16mmØ x 3.0m COPPER/ BRONZEGROUND ROD

1-5.5mm² COPPER STRANDEDWIRE WHITE

100AT, 125 AP, 230V,60 HZ

SCALE:E-3

3

N.T.S.

RISER DIAGRAM