Click here to load reader
Upload
marc-zerwin-muros
View
477
Download
3
Embed Size (px)
DESCRIPTION
a sample of power and auxiliary layout including the general notes for the electrical plans
Citation preview
REG. NO :
TIN NO :
PTR. NO :
DATE :
ENGINEER
SHEET CONTENTSPROJECT & LOCATION OWNER
DRAWN:
ALL PLANS AND SPECIFICATIONS, AS INSTRUMENTS
OF SERVICE, ARE THE PROPERTY OF THE DESIGNER
AND CANNOT BE COPIED OR DUPLICATED IN PART OR
IN WHOLE WITHOUT WRITTEN PERMISSION,THIS MUST
HAVE TO BE RETURNED WHEN NO LONGER IN USE.
SHT NUMBER
E-101
REG. NO :
TIN NO :
PTR. NO :
DATE :
ENGINEER
SHEET CONTENTSPROJECT & LOCATION OWNER
DRAWN:
ALL PLANS AND SPECIFICATIONS, AS INSTRUMENTS
OF SERVICE, ARE THE PROPERTY OF THE DESIGNER
AND CANNOT BE COPIED OR DUPLICATED IN PART OR
IN WHOLE WITHOUT WRITTEN PERMISSION,THIS MUST
HAVE TO BE RETURNED WHEN NO LONGER IN USE.
SHT NUMBER
E-201
1.
ELECTRICAL ENGINEER.
GENERAL NOTES:
3.
2.
4.
6.
5.
7.
2
9.
8.
11.
10.
SHALL BE MADE ACCORDINGLY.ALL MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED SHALL BE NEW AND MUSTBE OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE INTENDED.
ALL 20-AMPERE CIRCUIT HOMERUNS TO PANELBOARDS OF MORE THAN 30 METERS IN LENGTH SHALL BE 5.5mm UNLESS OTHERWISE SPECIFIED
VERIFIED WITH THE ENGINEER/OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES
WHERE REQUIRED. MINIMUM SIZE FOR ALL CONDUITS SHALL BE 15mm INSIDE DIAMETER
FOR PERMANENT CONNECTION WITH CONCRETE WALLING OR BEAM.
TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF UTILITIES & OTHER TRADES.
COPPER AND THERMOPLASTIC INSULATED TYPE THWN/THHN UNLESS OTHERWISE INDICATED. THEMINIMUM SIZE FOR POWER AND LIGHTING SHALL BE 3.5mm².THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF INCOMING POWERFOR CONNECTION INCLUDING THE LOCATION OF METER CENTER.ALL PIPE SLEEVES SHALL BE PROVIDED WITH PROPER SUPPORT OR ANCHORAGE NECESSARY
ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND ALLNON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN ACCORDANCE
CONDUIT ROUTING SHOWN IS ESSENTIALLY DIAGRAMMATICAL. CONTRACTOR SHALL LAY OUT RUNS
ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE
ELECTRICAL METALLIC CONDUIT (EMT). FLEXIBLE METALLIC CONDUITS SHALL ALSO BE USED THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN INTERMEDIATE METALLIC CONDUIT (IMC)
ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITHTHESE PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATESTEDITION OF THE PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THELOCAL ENFORCING AUTHORITY, AND THE REQUIREMENTS OF THE LOCAL POWER. THEELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED
THE ELECTRIC SERVICE VOLTAGE SHALL BE SINGLE PHASE 3-WIRE WITH GROUND 230V 60HZ.
ELECTRICAL TRADE SIZE MINIMUM SIZE OF PULLBOX TO BE USED SHALL BE 150x150x100mm.
ALL CONDUITS AND RACEWAY PENETRATIONS THROUGH FIRE OR SMOKE RATED WALLS AND FLOORSSHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAME AND HOT
12.
GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC OF FIRE STOPSASTM-E-814. PROVIDE A UL LISTED THROUGH PENETRATION FIRE STOP SYSTEM NUMBERED PER ULFIRE RESISTANCE DIRECTORY.
ALL WIRES FOR INDOOR INSTALLATION SHALL BE
WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS: SWITCHES : 1,370MM ABOVE FLOOR FINISH RECEPTACLES : 300MM ABOVE FLOOR FINISH
: 170MM ABOVE COUNTER TOP PANEL BOARD : 1800MM ABOVE FLOOR FINISH
13.
CHANDELIER
BRANCH CIRCUIT HOMERUN
LEGEND
1-40w FLUORESCENT LAMP
4"Ø / 6"Ø PINLIGHT
LIGHTING FIXTURE
E.RANGE OUTLET
REFRIGERATOR OUTLET
WEATHERPROOF OUTLET
ABOVE COUNTER OUTLET
DUPLEX CONVENIENCE OUTLET
PP01
KWHM KILOWATT-HOUR METERM
PP,LP,PB
CABLE TV OUTLET
TELEPHONE OUTLET
LIGHTING LINE, CONCEALED ON CLNG.
ELECTRICAL SERVICE ENTRANCE
SINGLE POLE SWITCH2-GANG SWITCH
POWER LN., EMBEDDED ON SLAB/WALL
ACU OUTLET
S2bc / S2
Sa / S
PANEL BOARD
GENERAL NOTES
POWER & AUXILIARY LAYOUT
POWER AND AUXILIARY LAYOUT
LIGHT SWITCHES DETAIL
CONVENIENCE OUTLET DETAIL
SCALE: 1:100 MTS.
POWER & AUXILIARY LAYOUT
E-11
150
PA
NE
L
TEL
CATV
LPA1
LPA2
SCALE: 1:100 MTS.
POWER & AUXILIARY LAYOUT
E-11
150
S2
S2
S2
S1
S1
PA
NE
L
JUAN DE LA CRUZ
JBS 08/07/13
JUAN DE LA CRUZ
JBS 08/07/13
LPA3
DESIGNER
DESIGNER
SERVICEENTRANCE
METERREADING
2-50mm² THHN STRANDED WIRE BLACK1-5.5mm² COPPER STRANDEDWIRE WHITE32mmØ RIGID STEEL CONDUIT PIPE(RSCP)
16mmØ x 3.0m COPPER/ BRONZEGROUND ROD
1-5.5mm² COPPER STRANDEDWIRE WHITE
100AT, 125 AP, 230V,60 HZ