POTTERTON GOLD – RANGE GUIDE

POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

PO

TT

ER

TO

N G

OL

D –

RA

NG

E G

UID

E

Page 2: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Potterton Gold.A track record of reliability.If it’s consistent reliability you’re after, install a Potterton Gold boiler and help your customers enjoy energy efficient heating and cost savings, day after day.

With 150 years of engineering excellence and over 7 million Potterton boilers built and installed, we’ve learned a thing or two about reliability. We’ve won awards along the way too, with the Potterton Gold Combi 24 HE A picking up a ‘Which? Best Buy’ award for efficiency, ease of use and durability in 2010.

We’re always looking to set new high standards. It’s why we continually invest millions of pounds in research, design and manufacturing to create a range that’s easy to install – and hard to beat. It’s why we put our boilers through their paces, carrying out a rigorous testing programme on every single one to make sure they’re fit for the job. And it’s why the Potterton Gold range comes with added cost saving features and a 2 year parts and labour warranty*, which is backed-up by heateam, our award-winning customer support service ranked top in the heating sector and 7th best overall in the UK**. All so we can give you – and your customers, every confidence and complete peace of mind.

There’s only one thing that matches our commitment to the reliability and performance of our models, and that’s the support we’ll give to you and your customers. From our easy- to-use website with access to help and advice, to 12 training centres and a wide range of courses – we’re here to help you build your skills, your business and your reputation.

Go for Gold with the Potterton Gold range. There’s nothing better than the warm feeling of satisfaction that comes from knowing you’ve achieved another personal best.

*Subject to registration and an annual service.**Recent UK Study carried out by independant market research company GFK mystery shopping

Introduction

“Our original Potterton boiler has never let us down, so I had no hesitation in replacing it with another. When something is so reliable, why change?” Ex-England football captain (and Potterton fan)

“I’ve been a Potterton installer for nearly 40 years. People ask for Potterton boilers by name, because they’ve had one and want another.” Potterton Installer (with a Royal Warrant), Marlow

Introduction

2

MADE IN THE UK

Page 3: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

3

A series of illustrations providing a guide for each of the flue systems required for Potterton Gold products. Accessories page 19.

PAGE

16

It might weigh only 26kg, but this fully modulating wall-mounted boiler punches well above its weight. 15kW, 18kW and 24kW.

Potterton Gold H (Heat only) PAGE

8

With state-of-the-art design, this genuine and powerful all-rounder can perform in a variety of applications. 18kW, 24kW and 28kW.

Potterton Gold System HE A PAGE

6

With proven HE technology and robust components, this award-winning boiler will always perform to deliver optimum performance. 24kW, 28kW (& 28kW LPG) and 33kW.

Potterton Gold Combi HE APAGE

4

A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible enough for a wide range of installations. 30kW.

Potterton Gold FSB 30 HEPAGE

10

A lightweight high output boiler providing larger homes with the heating and hot water demand they require while maintaining optimum efficiency.

Potterton Gold High Output PAGE

12

Provides efficient electric wet central heating for use with conventional radiators or underfloor heating systems. 4kW, 6kW, 9kW, 11kW and 12kW models.

Potterton Gold Electric Flow Boiler PAGE

14

Page 4: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Can be situated in an

unventilated cupboard

Fitted clock

Flue lengths up to 20m give

increased flexibility for siting

SEDBUK (2009)

88.9-91% efficient

dependent on output

4

In September 2010 the Potterton Gold Combi HE A was awarded Which? ‘Best Buy’ for efficiency, ease of use and durability.

Compact and packed with added features, the wall-mounted Potterton Gold Combi HE A combines long-term reliability and ease of installation, with high efficiency and ultra-low emissions. Available in 24kW, 28kW (& 28kW LPG) and 33kW outputs, it can be sited in a wide range of locations.

Potterton Gold Combi HE A KEY FEATURES & BENEFITS

Greater reliability Quality components, rigorous quality testing and our ongoing commitment to excellence all ensure we deliver trademark Potterton reliability.

Optimum performance A built-in pressure gauge allows for accurate central heating pressures, and makes for faster and more accurate commissioning of the system.

Easy to fit, even in difficult locations Extensive flue options of up to 20 metres give greater fitting flexibility, while a filling loop (fitted as standard) allows for easier installation.

Suitable for a wide range of properties Available in a variety of outputs, it’s suitable for most homes.

Free parts and total peace of mind Our 2 year parts and labour warranty goes much further than just a guarantee.*

Installer friendly The Potterton Gold Combi HE A comes supplied with a one piece pre-plumbing jig to give accurate alignment and allow first fix of system pipework (even without the boiler).

Consistent flow rates and consistently high customer satisfaction A reliable and proven Grundfos pump means greater comfort and significantly less maintenance.

2 year warranty*

Energy Saving

Trust Recomm

ended

E

Whi

ch? Se

ptem

ber 2

010

‘Bes

t

Buy’ fo

r eff

icie

ncy, e

ase

of

use

and

dura

bilit

y

Potter

ton

Gold

Combi

24

HE

A

Also

avai

labl

e in

LPG

*Subject to registration and an annual service.

Page 5: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Flue OptionsThe standard flue is suitable only for horizontal termination applications. Maximum permissible equivalent flue lengths are:

Horizontal Concentric 10/20* metresVertical Concentric 10/20* metresHorizontal/Vertical Twin Pipe 15 metres

*Depending on flue system used.

Any additional ‘in line’ bends in the flue system must be taken into consideration.

Their equivalent lengths are:

Concentric Pipes: 135° bend 0.5 metres 93° bend 1.0 metres

Twin Flue Pipe: 135° bend 0.25 metres 90° bend 0.5 metres

The elbow is now supplied with the flue system (not the appliance) and is not included in any equivalent length calculations. The Multifit flue illustrations show examples of permissible flue lengths. Instructions for guidance and fitting are included in each kit, where appropriate.

Potterton Gold Combi HE A can be fitted with the following flue systems:

Horizontal Concentric Flue System A Flue System G

Vertical Concentric Flue System A Flue System G

Twin Pipe Flue System N

Plume Displacement Kit Flue System K

Technical Information - 24, 28 & 33 HE ATechnical Information – 24, 28, 28 LPG & 33kW

5mm min in operation 450mm for servicing

5mm min450mm

200mm min

150mm min

5mm min

780mm

NB. Flue is offset to the right.

345mm

3° (1 in 20) or 1.5° providing flue has been adequately clamped as per installation instructions

PO

TT

ER

TO

N G

OL

D –

CO

MB

I HE

A

5

**Minimum flow rate 2.5 l/min when appliance used in conjunction with DHW flow restrictors.

Gold Combi HE Units 24kW 28kW 28kW LPG 33kW

Sales Code (Boiler only) 720207001 720207101 720519201 720207201Sales Code (Std Flue) & Elbow 60/100 5118489 5118489 5118489 5118489Sales Code (Boiler with Flue) 720217301 720217401 720519301 720217501ControlsConcealed User Controls Yes Yes Yes YesOperating Mode Selector Switch with Reset Yes Yes Yes YesUser Adjustable DHW temperature Yes Yes Yes YesUser Adjustable CH temperature Yes Yes Yes YesLCD Operating Status Display Yes Yes Yes YesLED Operating Status Display Yes Yes Yes YesIntegral 24hr Electro-Mechanical Timer Yes Yes Yes YesIntegral 7 day Electronic Timer Optional Optional Optional OptionalSingle Channel Wireless Programmable Room Thermostat Optional Optional Optional OptionalGasNatural Gas Yes Yes No YesLPG (Butane/Propane) No No Yes NoInlet Supply Pressure mbar 20 20 37 20Maximum Gas Rate m3/hr 2.61 3.1 2.25 3.6Central Heating Input (max) kW 22.7 27.4 27.4 32.1Central Heating Output - Condensing (max) kW 21 25.9 25.9 30.3Central Heating Output - Non Condensing (max) kW 20 24 24 28Domestic Hot Water Input (max) kW 27.4 32.1 32.1 37.7SEDBUK 2005 Seasonal Efficiency % 91.1 91.1 93.2 91.1SEDBUK 2009 Seasonal Efficiency % 89.0 89.0 91.0 88.9SEDBUK Rating Band A A A ANOx Class 5 5 5 5ElectricalElectrical Supply Volts/Hz 230/50 230/50 230/50 230/50Permanent Live Required Yes Yes Yes YesPower Consumption watts 155 155 155 160External Fuse Rating amps 3 3 3 3Integral 'Boiler Only' Frost Thermostat Yes Yes Yes YesMechanicalWall Mounting Jig Yes Yes Yes YesIsolating Valves Yes Yes Yes YesGas Supply Connection mm 22 22 22 22Central Heating Connections mm 22 22 22 22Domestic Hot Water Connections mm 15 15 15 15Condensate Drain Connection mm 21.5 21.5 21.5 21.5Safety Discharge Connection mm 15 15 15 15Filling Loop Kit Yes Yes Yes YesHydraulicDomestic Hot Water Output (Raised 35oC) (max) l/min 9.8 11.5 11.5 13.5Domestic Hot Water Operating Flow Rate (min) l/min 2** 2** 2** 2**Domestic Hot Water Operating Pressure (min) bar 0.15 0.15 0.15 0.15Domestic Hot Water System Pressure (max) bar 8 8 8 8Safety Discharge Pressure bar 3 3 3 3Integral Automatic Bypass Yes Yes Yes YesIntegral Expansion Vessel Capacity litres 8 8 8 10CH System Capacity (max) litres 125 125 125 155Compartment Ventilation Required No No No No24hr Pump Exercise Yes Yes Yes YesPump Overrun Yes Yes Yes YesConcentric Flue SystemsConcentric Flue Diameters mm 60/100 and 80/125Concentric Flue Length mm 685 685 685 685Max. Equivalent Vertical Length (Ø 60/100) m 10 10 10 10Max. Equivalent Vertical Length (Ø 80/125) m 20 20 20 20Max. Equivalent Horizontal Length (Ø 60/100) m 10 10 10 10Max. Equivalent Horizontal Length (Ø 80/125) m 20 20 20 20Twin Flue SystemTwin Pipe Flue Diameter mm 80/80 80/80 80/80 80/80Max. Equivalent Vertical Length m 15 15 15 15Max. Equivalent Horizontal Length m 15 15 15 15Plume Displacement KitMax. Equivalent Vertical Length m 13 13 13 8WeightsGross Packaged Boiler Weight kg 48.6 49.2 49.2 51Packaged Boiler Dimensions (LxWxD) mm 964 x 540 x 403Installation Lift Weight kg 43.6 44.2 44.2 46

Page 6: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

6

Offering a choice of outputs – 18kW, 24kW and 28kW – the Potterton Gold System HE A can meet the heating and hot water requirements of even the largest of properties – and all with the trademark Potterton reliability.

Potterton Gold System HE A KEY FEATURES & BENEFITS

Flexibility The Potterton Gold System HE A is available in three models, covering outputs from 18kW to 28kW. Extensive flue options also give you and homeowners greater siting choice and flexibility.

Free parts and total peace of mind Our 2 year parts and labour warranty goes much further than just a guarantee.*

Easy to learn, easy to fit A one piece pre-plumbing jig allows for quicker and easier installation, saving both time and installation costs.

Better protection A built in frost thermostat helps protect the boiler from freezing and damage, as well as opening up new site possibilities, such as in a garage or utility room.

Less heat waste, less time waste An integral system bypass means you don’t need to spend precious time ensuring adequate heat loss.

Can be situated in an

unventilated cupboard

Integral frost protection

Flue lengths up to 20m give

increased flexibility for siting

SEDBUK (2009)

89% efficient

2 year warranty*

Energy Saving

Trust recomm

ended

E

*Subject to registration and an annual service.

Page 7: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

PO

TT

ER

TO

N G

OL

D –

SY

ST

EM

HE

A

7

Flue OptionsThe standard flue is suitable only for horizontal termination applications. Maximum permissible equivalent flue lengths are:

Horizontal Concentric 10/20* metresVertical Concentric 10/20* metresHorizontal/Vertical Twin Pipe 15 metres

*Depending on flue system used.

Any additional ‘in line’ bends in the flue system must be taken into consideration.

Their equivalent lengths are:

Concentric Pipes: 135° bend 0.5 metres 93° bend 1.0 metres

Twin Flue Pipe: 135° bend 0.25 metres 90° bend 0.5 metres

The elbow is now supplied with the flue system (not the appliance) and is not included in any equivalent length calculations. The Multifit flue illustrations show examples of permissible flue lengths. Instructions for guidance and fitting are included in each kit, where appropriate.

Potterton Gold System HE A can be fitted with the following flue systems:

Horizontal Concentric Flue System A Flue System G

Vertical Concentric Flue System A Flue System G

Twin Pipe Flue System N

Plume Displacement Kit Flue System K

345mm

3° (1 in 20) or 1.5° providing flue has been adequately clamped as per installation instructions

5mm min450mm

200mm min

150mm min

5mm min

780mm

NB. Flue is offset to the right.

Technical Information – 18, 24 & 28kW

Gold System HE Units 18kW 24kW 28kW

Sales Code (Boiler only) 720518601 720518701 720518801Sales Code (Std Flue) & Elbow 60/100 5118489 5118489 5118489Sales Code (Boiler with Flue) 720518901 720519001 720519101ControlsConcealed User Controls Yes Yes YesOperating Mode Selector Switch with Reset Yes Yes YesUser Adjustable CH Temperature Yes Yes YesLCD Operating Status Display Yes Yes YesLED Operating Status Display Yes Yes YesGasGas (Natural Gas/LPG) NG NG NGInlet Supply Pressure mbar 20 20 20Maximum Gas Rate m3/hr 1.95 2.61 3.10Central Heating Input (max) kW 20.5 27.4 32.1Central Heating Output - Condensing (max) kW 19.4 25.9 30.3Central Heating Output - Non Condensing (max) kW 18 24 28SEDBUK 2005 Seasonal Efficiency % 91.2 91.2 91.2SEDBUK 2009 Seasonal Efficiency % 89.0 89.0 89.0SEDBUK Rating Band A A ANOx Class 5 5 5ElectricalElectrical Supply Volts/Hz 230/50 230/50 230/50Permanent Live Required Yes Yes YesPower Consumption watts 140 150 160External Fuse Rating amps 3 3 3Boiler IPX Rating (Electrical Protection) IPX 5D IPX 5D IPX 5DIntegral 'Boiler Only' Frost Thermostat Yes Yes YesMechanicalWall Mounting Jig Yes Yes YesIsolating Valves Yes Yes YesGas Supply Connection mm 22 22 22Central Heating Connections mm 22 22 22Condensate Drain Connection mm 21.5 21.5 21.5Safety Discharge Connection mm 15 15 15Filling Loop Kit Yes Yes YesHydraulicIntegral Automatic Bypass Yes Yes YesIntegral Expansion Vessel Capacity litres 8 8 10CH System Capacity (max) litres 125 125 125Compartment Ventilation Required No No No24hr Pump Exercise Yes Yes YesPump Overrun Yes Yes YesConcentric Flue SystemsConcentric Flue Diameters mm 60/100 and 80/125Concentric Flue Length mm 685 685 685Max. Equivalent Vertical Length (Ø 60/100) m 10 10 10Max. Equivalent Vertical Length (Ø 80/125) m 20 20 20Max. Equivalent Horizontal Length (Ø 60/100) m 10 10 10Max. Equivalent Horizontal Length (Ø 80/125) m 20 20 20Twin Flue SystemTwin Pipe Flue Diameter mm 80/80 80/80 80/80Max. Equivalent Vertical Length m 15 15 15Max. Equivalent Horizontal Length m 15 15 15Plume Displacement KitMax. Equivalent Vertical Length m 14 8 14WeightsGross Packaged Boiler Weight kg 43.6 44.2 46Packaged Boiler Dimensions (LxWxD) mm 964 x 540 x 403Installation Lift Weight kg 38.6 39.2 41

5mm min in operation 450mm for servicing

Page 8: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

8

Deceptively small but powerful and perfectly formed, Potterton Gold H is a fully modulating wall-mounted boiler available in 15kW, 18kW, 24kW outputs. Its slimline styling makes it ideally suited to installation in standard kitchen units. It’s quick and easy to fit too.

Potterton Gold H (Heat Only)

KEY FEATURES & BENEFITS

Less mess There’s no wiring between the pump and boiler, saving time and damage to surroundings.

Top efficiency rating and energy performance Rated SEDBUK (2005) Band A, it offers the very highest levels of efficiency.

Easy to fit, even in difficult locations Multi-directional flue options give solutions for on-site restrictions.

Compact size for discrete siting At 66mm x 390mm x 280mm, the Potterton Gold H can fit within a kitchen wall unit.

Free parts and total peace of mind Our 2 year parts and labour warranty goes much further than just a guarantee.*

Cost saving features as standard Full modulation automatically regulates output, helping lower fuel consumption.

Lightweight design, makes light work of installation With a dry lift weight of 26kg, it’s easy to move and manoeuvre.

Customer confidence An Energy Saving Trust recommendation provides evidence of carbon saving and ‘best-in-class’ performance.

Can be situated in an

unventilated cupboard

2 year warranty*

Flue lengths up to 50m give

increased flexibility for siting

SEDBUK (2009)

88.7-89% efficient

dependent on output

Energy Saving

Trust recomm

ended

E

*Subject to registration and an annual service.

Page 9: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Technical Information – 15, 18 & 24kW

Potterton Gold H can be fitted with the following flue systems:

Horizontal ConcentricFlue System B

Vertical ConcentricFlue System B

Twin PipeFlue System P

Plume Displacement KitFlue System L

PO

TT

ER

TO

N G

OL

D –

H (H

EA

T O

NL

Y)

9

280mm

5mm min in operation 500mm for servicing

3° (1 in 20) or 1.5° providing flue has been adequately clamped as per installation instructions

5mm min390mm

200mm min

5mm min

600mm

50mm min

Gold H (Heat Only) Units 15kW 18kW 24kWSales Code (Boiler only) 720512501 720512601 720512701Sales Code (Std Flue) 236921 236921 236921Sales Code (Boiler with Flue) 720518301 720518401 720518501ControlsConcealed User Controls Yes Yes YesLED Operating Status Display Yes Yes YesGasGas (Natural Gas/LPG) NG NG NGInlet Supply Pressure mbar 20 20 20Maximum Gas Rate m3/hr 1.64 1.94 2.31Central Heating Input (max) kW 16.9 20.2 24.5Central Heating Output - Condensing (max) kW 16.5 19.27 23.8Central Heating Output - Non Condensing (max) kW 15.2 17.8 22SEDBUK 2005 Seasonal Efficiency % 91.3 90.4 90.9SEDBUK 2009 Seasonal Efficiency % 89.0 88.7 88.8SEDBUK Rating Band A A ANOx Class 5 5 5ElectricalElectrical Supply Volts/Hz 230/50 230/50 230/50Permanent Live Required No No NoPower Consumption watts 80 80 80External Fuse Rating amps 3 3 3Boiler IPX Rating (Electrical Protection) IPX2 IPX2 IPX2Integral ‘Boiler Only’ Frost Thermostat No No NoMechanicalGas Supply Connection inch 1/2” BSP 1/2” BSP 1/2” BSPCentral Heating Connections mm 22 22 22Condensate Drain Connection mm 21.5 21.5 21.5Upward Piping Route Yes Yes YesHydraulicSafety Discharge Pressure bar 3 3 3Compartment Ventilation Required No No NoConcentric Flue SystemsConcentric Flue Diameter mmConcentric Flue Length mm 800 800 800Max. Equivalent Vertical Length (70/110) m 4 4 4Max. Equivalent Horizontal Length (70/110) m 4 4 4Twin Flue SystemTwin Pipe Flue Diameter mm 80/80 80/80 80/80Max. Equivalent Vertical Length m 75 75 75Max. Equivalent Horizontal Length m 75 75 75Plume Displacement KitMax. Equivalent Vertical Length m 29 29 29WeightsGross Packaged Boiler Weight kg 36.2 36.2 36.2Packaged Boiler Dimensions (LxWxD) mm 670 x 465 x 420Installation Lift Weight kg 26 26 26

Flue OptionsThe standard flue is suitable only for horizontal termination applications. Maximum permissible equivalent flue lengths are:

Horizontal Concentric 4* metresVertical Concentric 4* metresHorizontal/Vertical Twin Pipe 75 metres

*Depending on flue system used.

Any additional ‘in line’ bends in the flue system must be taken into consideration.

Their equivalent lengths are:

Concentric Pipes: 135° bend 0.5 metres 93° bend 1.0 metres

Twin Flue Pipe: 135° bend (Air Duct) 1.3 metres 135° bend (Flue Duct) 2.6 metres 91.5° bend (Air Duct) 4.8 metres 90° bend (Flue Duct) 9.6 metres

The elbow is now supplied with the flue system (not the appliance) and is not included in any equivalent length calculations. The Multifit flue illustrations show examples of permissible flue lengths. Instructions for guidance and fitting are included in each kit, where appropriate.

Page 10: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

A floor-standing boiler with maximum flexibility, the Potterton Gold FSB 30 HE can be used with a range of flueing options, on fully pumped, open or sealed systems.

Potterton Gold FSB 30 HE KEY FEATURES & BENEFITS

One size fits all Fully modulating from 9.2kW to 30.2kW it is suitable for a wide range of installations.

Installer friendly With built-in frost protection and no compartment ventilation required, installation of this boiler is quick and easy.

Versatility of siting Small enough to fit under a standard worktop, an integral condensate pump and a comprehensive range of flueing options allows the boiler to be easily sited.

Adaptable Suitable for fully pumped open vented and sealed sytems providing heating and hot water.

Free parts and total peace of mind Our 2 year parts and labour warranty goes much further than just a guarantee*.

In-built condensate pump

- can be situated in basement

Fully modulating

Integral frost protection

SEDBUK (2009)

88.8% efficient

Ultra-low NOx em

issions.

Class 5 (the best)

*Subject to registration and an annual service.

10

2 year warranty*

Page 11: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Technical Information – 30kW

The Potterton Gold FSB 30 HE can be fitted with the following flue systems:

Horizontal ConcentricFlue System B

Vertical ConcentricFlue System B

Twin PipeFlue System P

Plume Displacement KitFlue System L

Flue OptionsConcentric Flue The maximum equivalent lengths are 4m (horizontal and vertical). These lengths exclude the standard elbow and flue/terminal assembly (horizontal) and terminal assembly (vertical).

Twin Flue The total maximum permissible equivalent flue length for calculation purposes is 150m, however, in reality only 100m of physical flue pipe will be used, i.e. where air and flue pipes run parallel, the maximum permissible flue length per tube is 50m. Flue tubes should be counted as 2m and air tubes as 1m for this calculation.

Any additional ‘in line’ bends in the flue system must be taken into consideration.

Their equivalent lengths are:

Concentric Pipes: 135° bend 0.5 metres 93° bend 1.0 metres

Twin Flue Pipe: 135° bend (air/flue) 1.3/2.6 metres 90° bend (air/flue) 4.8/9.6 metres

The elbow is now supplied with the flue system (not the appliance) and is not included in any equivalent length calculations. Detailed examples of equivalent flue length calculations are given in the Installation Guidance Notes for each flue system type (Documents 243501 and 243502 for concentric and twin pipe respectively).

5mm min390mm

15mm min

5mm min

850mm

(25mm if under non removable worktop)

520mm

5mm min in operation 500mm for servicing

3° (1 in 20) or 1.5° providing flue has been adequately clamped as per installation instructions

PO

TT

ER

TO

N G

OL

D –

FS

B

Potterton Gold FSB 30 HE Units 30kWSales Code (Boiler only) 72080601Sales Code (Std Flue) 236921Sales Code (Boiler with Flue) 720890501ControlsConcealed User Controls YesOperating Mode Selector Switch with Reset YesUser Adjustable CH Temperature YesLED Operating Status Display YesIntegral 7 day Twin Channel Timer OptionalGasGas (Natural Gas/LPG) NGInlet Supply Pressure mbar 20Maximum Gas Rate m3/hr 3.4Max. Central Heating Input kW 33.76Min. Central Heating Input kW 10.3Max. Central Heating Output (Non Condensing) kW 30.18Min. Central Heating Output (Non Condensing) kW 9.2Max. Central Heating Output (Condensing) kW 32.61Min. Central Heating Output (Condensing) kW 10SEDBUK 2005 Seasonal Efficiency % 90.9SEDBUK 2009 Seasonal Efficiency % 88.8SEDBUK Rating Band ANOx Class 5NOx Levels Mg/kWhr 48EcoHomes Credits 2ElectricalElectrical Supply Volts/Hz 230/50Permanent Live Required YesPower Consumption Watts 80External Fuse Rating Amps 3Integral ‘Boiler Only’ Frost Thermostat YesMechanicalGas Supply Connection mm 15Flow & Return Pipe Connection mm 28Condensate Drain Connection mm 10HydraulicSafety Discharge Pressure bar 3Compartment Ventilation Required NoConcentric Flue SystemsConcentric Flue Diameter mm 70/110Concentric Flue Length mm 850Max. Equivalent Vertical Length (Ø 70/110) m 4Max. Equivalent Horizontal Length (Ø 70/110) m 4Twin Flue SystemTwin Pipe Flue Diameter mm 80/80Max. Equivalent Vertical Length m 50Max. Equivalent Horizontal Length m 50Plume Displacement KitMax. Equivalent Vertical Length m 22WeightsGross Packaged Boiler Weight kg 49.5

11

Page 12: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

A lightweight, high output heating appliance. Low noise and easy to install, the Potterton Gold High Output is extremely energy efficient and uses the latest stainless steel heat exchanger technology in conjunction with a sophisticated control system that delivers maximum condensing performance. Potterton Gold High Output boilers are easy to maintain with excellent internal space for providing access to key components.

Potterton Gold High Output

KEY FEATURES & BENEFITS

Energy efficient Using the very latest in technology the combustion system delivers exceptional energy efficiency exceeding Part L of the building regulations (seasonal efficiency 94%).

Intelligent thinking Fully modulating burner control automatically adapts the boiler output to help lower fuel consumption, reducing annual fuel bills.

Fuel flexibility Suitable for use with natural gas or LPG.

Sophisticated controls User friendly display panel, versatile boiler controls and full onboard diagnostics allow the installer and homeowner complete control over their heating and hot water needs.

Customer comfort Available with a wide range of accessories and a 2 year parts and labour warranty*, the boiler is designed to deliver greater comfort to the homeowner.

The service team for this appliance can be contacted on 0845 070 1058

*Subject to registration and an annual service.

12

Potterton Gold High Output

Page 13: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Technical Information – 46 & 65WH

Potterton Gold High Output can be fitted with the following flue systems:

Horizontal ConcentricFlue System G

Vertical ConcentricFlue System G

Twin PipeFlue System P

Flue OptionsThe standard flue is suitable only for horizontal termination applications. Maximum permissible equivalent flue lengths are:

Horizontal Concentric 9* metres Vertical Concentric 9* metres

*Depending on flue system used

Any additional ‘In Line’ bends in the flue system must be taken into consideration.

Their equivalent lengths are:

Concentric Pipes: 135° 0.5 Metres 93° 1.0 metres

13

Optional Extras

Low Loss Header - provides hydraulic separation between the boiler (primary circuit) and the heating system (secondary circuit). This ensures any varying water flow through the heating system will have no effect on the primary boiler circuit and allows for a number of heating zones of different load and temperature requirements, with the boiler providing a constant temperature and water flow through the primary circuit. (Sales code 5103855)

Remote Room Thermostat - allowing simple temperature control. (Sales code 5116429)

Boiler Sequence Controller - wall mounted sequential controller, for up to 12 boilers in a cascade, complete with outside weather sensor for direct weather compensation. When using this product an additional clip-in interface will be required for each boiler in the cascade. (OCI 420 Sales code 5116431)

Clip-in Interface - for use with variable temperature heating circuits, allows control of a second heating pump and 3-way mixing valve. (Sales code 5116430)

Programmable Room Thermostat - programmable up to 3 phases per day, holiday functions and frost protection. (Sales code 5116426)

950mm

466mm600mm

*According to EN 60529

PO

TT

ER

TO

N G

OL

D –

HIG

H O

UT

PU

T

Additional options Outside weather sensor for single boiler direct weather compensation. (Sales code 5104726) Domestic hot water temperature sensor for use when hot water control is required using an indirect cylinder. (Sales code 5116436)

Model High Output Units WH 46 WH 65Sales Code (Boiler Only) 5103857 5103858Sales Code (Std Flue) 5138527ControlsUser Adjustable CH temperature Yes YesIntegral 24 hr Time Control Yes YesLCD Operating Statues Display Yes YesOn Board Fault Diagnostics Yes YesOn Board Direct Weather Compensation Optional OptionalOn Board DHW Cylinder Time and Temperature Control Optional OptionalRemote Programable Room Temperature Control Optional OptionalGasGas Consumption (NG) m3/h 4.91 6Gas Consumption (LPG) m3/h 1.89 2.31Max. Gas Inlet Gas Pressure (NG) mbar 20 20Max. Gas Inlet Gas Pressure (LPG) mbar 37 37Max. Heat Input (Gross) kW 51.5 62.9Max. Heat Output (Condensing) kW 48.7 59.5Reduced Heat Output (Condensing) kW 15.8 16.8Max Heat Output (Non Condensing) kW 45 55Reduced Heat Output (Non Condensing) kW 14.5 15.5Part L2 Seasonal Efficiency % 94 94NOx Class 5 5CO2 for Natural Gas % 8.7 8.7CO2 for LPG % 10 10Max. Flue Gas Temperature °C 74 75Max. Flue Gas Flow Rate kg/s 0.022 0.032ElectricalPermanent Live Required Yes YesElectrical Supply Volts/Hz 230/50 230/50Maximum Electrical Power Consumption Watts 75 125Protection Against Humidity and Water Leakage IPX5D * IPX5D *Integral ‘Boiler Only’ Frost Protection Yes YesMechanicalFlow & Return Connection Size BSP 1” 1”Gas Connection Size BSP 3/4” 3/4”Condensate Drain Connection mm 22 22HydraulicMinimum Operating Pressure bar 1 1Maximum Operating Pressure bar 4 4

Kpa 31.38 34.32Kpa 11.7 20.6Kpa 10.79 11.77lit/sec 0.72 1.04lit/sec 0.54 0.78lit/sec 0.36 0.52

Maximum Flow Temperature °C 85 85Water Content litres 5.1 6.5Compartment B Ventilation Required Yes YesConcentric Flue SystemsConcentric Flue Diameter mm 80/125 80/125Max. Equivalent Vertical Length m 9 9Max. Equivalent Horizontal Length m 9 9Twin Flue SystemsTwin Pipe Flue Diameter mm 80 80Max. Equivalent Length m 14.5 14.5WeightsBoiler Dry Weight kg 64 72Gross Packaged Weight kg 69 77

5138527

Page 14: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Designed to heat re-circulated water used in wet central heating systems. No flue or fuel tank makes the Potterton Gold Electric Flow Boiler 99.8% efficient. Available in 4kW, 6kW, 9kW, 11kW and 12kW models.

The Potterton Gold Electric Flow Boiler

KEY FEATURES & BENEFITS

Installation friendly The lightweight design makes for easy handling, whilst compatibilty with standard radiators, programmers, pumps, room thermostats and thermostatic radiator valves gives you hassle-free installation.

Low maintenance and long-life reliability Solid state technology and the absence of moving parts ensure a longer service life, while our 2 year on-site parts and labour warranty* gives added peace of mind. You don’t even need an annual safety certificate!

Controllable efficiency As well as a soft start and zero volt switching to help avoid power surges, min/max controls make it easy to adjust the water temperature output from the boiler, helping you get the most from wet central heating.

Easy to use A front panel indication gives you an ‘at a glance’ reading for the boiler state.

Versatile Suitable for both pressurised or open- vented systems, it gives domestic hot water from the boiler in conjunction with either an indirect or separate direct cylinder.

Compact and discreet Sleek and ‘slim-fit’ in construction, it also runs silently – so you’ll hardly know it’s there.

14*Subject to registration and an annual service.

Page 15: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Technical Information – 4, 6, 9, 11 & 12kW

35mmPipe flow36 litre/min

28mmPipe flow24 litre/min

22mmPipe flow12 litre/min

22mmPipe flow12 litre/min

28mmPipe flow24 litre/min

35mmPipe flow36 litre/min

RELIEF SYSTEM

PUMP

FLOW

RETURN

SERVICEVALVE

RELAYSYSTEM94970058

DRAINVALVE

ModelBoiler Output

Model 220v/Btu 240v/Btu

94022008 4kW 3.5kW/11,900 4kW/13,600

94022004 6kW 5kW/17,000 6kW/20,400

94022005 9kW 7.5kW/25,600 9kW/30,700

94022006 11kW 9kW/30,700 11kW/37,500

94022007 12kW 10kW/34,000 12kW/40,900

Model Part No. Description Comment

RL1 94970056 1 relay assembly Suitable for linking an electrical shower with the boiler to ensure that both do not run at the same time preventing overloading of the electrical supply

RL2 94970057 2 relay assembly 2x boiler pump isolation relay suitable for boilers being connected on single phase or 3 phase supplies

RL3 94970058 3 relay assembly 3x boiler pump isolation relay suitable for boilers being connected on single phase or 3 phase supplies

Specifications & dimensions

Output temperature control range: (Radiator) 65°C to 80°C

(Underfloor) 30°C to 60°C

Operating voltage 200V - 245V/50Hz

Pump supply fuse (internal) T 2A 240V - 20x5mm

‘RUN’ control input signal requires 200V - 245V/50Hz

‘RUN’ control input signal draws less than 0.25A 10mA typical

Optical isolation Between the control signals and the boiler supply

Over temperature trips 95 and 100°C

Water content 1.3 litres

PO

TT

ER

TO

N G

OL

D –

EL

EC

TR

IC B

OIL

ER

15

Page 16: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Vertical Concentric Flues 60/100mm Flue System A

To make sure our boilers are easy to fit, we’ve developed ‘Multifit’ – a unique range of fully compatible flue components. Working across the Potterton Gold range, they help ensure trouble-free installation, whatever the task. The following illustrations show you what’s available, and how they can help.

Please note: Potterton products are no longer supplied with a flue elbow in the boiler packaging.

*In addition, the terminal should be no nearer than 150mm to an opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame. See BS 5440 Pt1.

†Reduced clearances This range of boilers has been tested and approved for use with certain clearances less than those shown. Horizontal flues in positions D, E, F, G & H(i) may be reduced to 25mm. H(ii) may only be reduced to 115mm. Only one of these reductions may be used on a single installation.

16

Item Description Flue System A

Specification KEY & OD Dimensions

Sales Code

Standard Horizontal Flue inc Elbow 685mm 60/100mm 5118489

Standard Horizontal Telescopic Flue inc Elbow 315-500mm 60/100mm 5118069

Telescopic Internal Flue Kit 5119654

Flue Extension 1000mm 100mm 5111074

Flue Bend (Pair) 135 degrees 100mm 5111085

Flue Bend 135 degrees 100mm 5111076

Flue Bend 93 degrees 100mm 5111075

Flue Wall Liner 5111067

Flue Terminal Deflector 5111068

Pipe Support Painted white 5111080

Item Description Flue System A

Specification KEY & OD Dimensions

Sales Code

Vertical Flue Terminal 100mm 5118576

Roof Cover Plate 125mm 246143

Flue Extension 1000mm 100mm 5111074

Flue Bend 93 degrees 100mm 5111075

Flue Bend (Pair) 135 degrees 100mm 5111085

Flue Bend 135 degrees 100mm 5111076

Pipe Support Painted white 5111080

Pitched Roof Flashing 25/50 degree 125mm 5122151

Flue Vertical Adaptor (Boiler) 125mm 246144

Horizontal Concentric Flues 60/100mm Flue System A

Multifit Flue Illustrations

Terminal Position with Minimum Distance (mm)

A* Directly below an opening, air brick, opening windows etc. 300

B* Above an opening, air brick, opening window etc. 300

C* Horizontally to an opening, air brick, opening window etc. 300

D† Below gutters, soil pipes or drain pipes. 150

E† Below eaves. 200

F† Below balconies or carport roof. 200

G† From a vertical drain pipe or soil pipe. 150

H† From an internal (i) or external (ii) corner. 300

I Above ground, roof or balcony level. 300

J From a surface or boundary line facing a terminal. 600

K From a terminal facing a terminal (horizontal flue). 1200

K From a terminal facing a terminal (vertical flue). 600

L From an opening in carport (e.g. door, window) into the dwelling.

1200

M Vertically from a terminal on the same wall. 1500

N Horizontally from a terminal on the same wall. 300

R From adjacent wall to flue (vertical only). 300

S From an adjacent opening window (vertical only). 1000

Page 17: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

25

Horizontal Concentric Flues 70/110mm Flue System B

17

Item Description Flue System B

Specification KEY & OD Dimensions

Sales Code

Standard Horizontal Flue inc Elbow 850mm 110mm 236921

Horizontal Flue/Wall Terminal 850mm 110mm 243013BAX

Flue Extension 1000mm 110mm 241695

Flue Extension 500mm 110mm 241694

Flue Extension 250mm 110mm 241692

Flue Bend 90 degrees 110mm 241687

Flue Bend (Pair) 135 degrees 110mm 241689

Flue Terminal Deflector 248167

Vertical Flue Adaptor (Boiler) 110mm 5106888

Pipe Support Painted White 243014BAX

Item Description Flue System B

Specification Key & OD Dimensions

Sales Code

Vertical Roof Terminal 70/110mm 242802

Flue Extension 1000mm 110mm 241695

Flue Extension 500mm 110mm 241694

Flue Extension 250mm 110mm 241692

Flue Bend 90 degrees 110mm 241687

Flue Bend (Pair) 135 degrees 110mm 241689

Roof Cover Plate 243131

Pipe Support Painted White 110mm 243014BAX

Flat Roof Flashing 125mm 243016BAX

Pitched Roof Flashing 25/50 degrees 125mm 243015

Vertical Flue Adaptor (Boiler) 110mm 5106888

Vertical Concentric Flues 70/110mm Flue System B

Item Description Flue System G

Specification Key & OD Dimensions

Sales Code

Horizontal Flue inc Boiler & Terminal Adaptors

125mm 5118580

Horizontal Flue Terminal inc 91.5 degree flue bend

Potterton Gold High Output only 125mm 5138527

Flue Extension 1000mm 125mm 5118584

Flue Bend 91.5 degrees 125mm 5118588

Flue Bend (Pair) 135 degrees 125mm 5118597

Pipe Support For use with 125mm Flue Pipes 125mm 5118610

Horizontal Concentric Flues 80/125mm Flue System G

Page 18: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

Item Description Flue System G

Specification Key & OD Dimensions

Sales Code

Vertical Flue Terminal 125mm 5111078

Flue Extension 1000mm 125mm 5118584

Flue Bend 91.5 degrees 125mm 5118588

Flue Bend (Pair) 135 degrees 125mm 5118597

Roof Cover Plate 125mm 246143

Flue Vertical Adaptor 100/125mm 5111070

Pitched Roof Flashing 25/50 degrees 125mm 5122151

Flat Roof Flashing 125mm 246144

Pipe Support For use with 125mm Flue Pipes 125mm 5118610

Vertical Concentric Flues 80/125mm Flue System G

Twin Pipe Flues 80/80mm Flue System N

Twin Pipe Flues 80/80mm Flue System P

Item Description Flue System N

Specification Key & OD Dimensions

Sales Code

Vertical Flue Terminal 125mm 5111078

Twin Pipe Extension (Pair inc Brackets) 1000mm 80mm 5111087

Twin Pipe Flue Bend (Pair) 90 degrees 80mm 5111072

Twin Pipe Flue Bend (2 Pair) 135 degrees 80mm 5111086

Roof Cover Plate 125mm 246143

Twin Pipe Flue Horizontal Terminal Kit (Pair)

80mm 5120172

Twin Pipe Support (Pair) Painted White 80mm 5111081

Twin to Concentric Adaptor 80/80 - 80/125 80/125mm 5111084

Pitched Roof Flashing 25/50 degrees 125mm 5122151

Flat Roof Flashing 125mm 246144

Twin Pipe Flue Adaptor (Boiler) 80mm 720089801

Item Description Flue System P

Specification Key & OD Dimensions

Sales Code

Horizontal Flue Terminal 850mm 110mm 243013BAX

Vertical Roof Terminal 70/110mm 242802

Twin Pipe Flue Extension 1000mm 80mm 246137

Twin Pipe Flue Extension 500mm 80mm 246136

Twin Pipe Flue Extension 250mm 80mm 246135

Twin Pipe Flue Bend (2 Pair) 135 degrees 80mm 5121561

Twin Pipe Flue Bend (Pair) 90 degrees 80mm 5121560

Twin Pipe Support (Pair) Painted White 80mm 5111081

Pipe Support Painted White 110mm 243014BAX

Pitched Roof Flashing 25/50 degrees 125mm 243015

Flat Roof Flashing 125mm 243016BAX

Twin Pipe Flue Adaptor Set 80/80mm 242757

Flue Terminal Deflector 248167

Roof Cover Plate 243131

18

Page 19: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

19

Item Description Flue System K

Specification Key & OD Dimensions

Sales Code

Plume Displacement Kit inc Elbow & Clips 100mm 5118638

Plume Displacement Kit Extension inc Clip 1000mm 60mm 5121368

Plume Displacement Kit Bend 93 degrees 60mm 5121369

Plume Displacement Kit Bend (Pair) 135 degrees 60mm 5121370

Item Description Flue System L

Specification Key & OD Dimensions

Sales Code

Plume Displacement Kit inc Elbow & Clips 110mm 5121371

Plume Displacement Kit Extension inc Clip 1000mm 70mm 5121372

Plume Displacement Kit Bend 93 degrees 70mm 5121373

Plume Displacement Kit Bend (Pair) 135 degrees 70mm 5121374

Plume Displacement 60/100mm Concentric to 60mm PDK – Flue System K

Plume Displacement 70/100mm Concentric to 70mm PDK – Flue System L

Item Description Specification Key Sales Code

1 Integral 7 Day Electronic Timer Combi Boilers only Image 1 247207

2 Wireless Timer Room Thermostat Combi Boilers only Image 2 5117392

3 Multifit GasSaver Combi Boilers only Image 3 720056901

4 Fernox Gold Filter 22mm

Fernox Gold Filter 28mm

Hydrocyclonic and

Magnetic In-line Filter

Image 4 59982

59983

5 Stand Off Kit 40mm Combi and System Boilers only Image 5 5117035

Electronic Timer Giving you maximum versatility, this sophisticated but simple to use timer lets you programme the system over a 7 day period. Offering a full selection of on/off switching operations, it features an advanced switch programme and easy to read digital LCD display.

Wireless Timer Room ThermostatAs easy to fit as it is to use, this programmable room thermostat brings greater control (and cost savings), while minimising issues of compliance with Building Regulations Part L (Energy Conservation) and Part P (Electrical Safety).

Multifit GasSaver A flue gas recovery device designed to sit between the boiler and flue. The GasSaver recycles the heat from the flue gases which would normally be expelled into the atmosphere to preheat DHW.

Fernox Gold Filter The Fernox Gold Filter is an in-line filter, which combines hydrocyclonic action with specially designed magnet assemblies, to remove magnetic and non-magnetic contaminants from system water and contain them safely within the filter.

Optional Accessories

Item Description Flue System G

Specification Key & OD Dimensions

Sales Code

PMK Plume Kit 125mm 5136902

Plume 90 Degree Elbow 90 degrees 80mm 5138535

PMK 1m Extension inc wall bracket 1000mm 80mm 5138537

PMK 45 Degree Elbow 45 degrees 80mm 5138536

Plume Displacement 80/125mm Concentric to 80mm PDK – Flue System G

1.

2.

3.

4.

5.

Page 20: POTTERTON GOLD – RANGE GUIDE - Trade Plumbing Gold...Potterton Gold Combi HE A PAGE 4 A floor-standing boiler designed to fit easily and quickly under a standard worktop, flexible

PO

TT

ER

TO

N G

OL

D –

RA

NG

E G

UID

E

General enquiries Tel: 0844 871 1560

Please note Calls to the contact centre may be recorded or monitored for training purposes.

Potterton Brooks House, Coventry Road, Warwick CV34 4LL. Website: www.pottertongold.co.uk

Potterton policy is one of continual improvement and development. The right

to change specification and appearance without prior notice is reserved. The

reproduction of colours is as accurate as photographic and printing processes

allow. The consumer’s statutory rights are not affected. e&oe.

PottGold/V2/May12/376096/03

You can rely on

This brochure is printed on paper sourced from well-

managed forests and other controlled sources. This

brochure is printed using vegetable based inks. Please

recycle this brochure when you have finished with it.

MADE IN THE UK