THE SCIENCE OF CERTAINTY®

PosiBand®

Unique contact technology that eliminates the weaknesses of the split-finger design

Page 2: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 2

• The PosiBand female contact configuration features a higher cross-sectional area of material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact.

• PosiBand has greater surface engagement at the male and female contact interface, resulting in more consistent electrical performance.

• Resistance of size 22 contacts is 5 milliohms, maximum. Resistance of size 20 contacts is 4 milliohms, maximum. Low contact resistance offers opportunities to use size 22 and size 20 contacts for power.

• PosiBand has lower average insertion forces, resulting in greater ease in mating, especially in larger high density connectors. The average lower insertion force is accomplished while meeting or exceeding performance requirements.

• As the PosiBand external pressure element performs the mechanical action of the connection, the contact body material can be selected from a large spectrum of alloys featuring higher conductivity or superior crimp deformation properties, eliminating the need for further processing such as annealing.

• PosiBand is qualified under SAE AS3902 and MIL-DTL-24308 specifications. PosiBand is also qualified to the higher 40 gram contact separation test requirement of GSFC S-311-P4/08 and GSFC S-311-P4/10.

What makes the PosiBand contact design an improvement?

Page 3: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 3

Separation & Surface Engagement Summary

Over separation results in reduced normal force and degradation of electrical performance.

Over-separation is limited by insulator cavity

Surface engagement

concentrated at the tip

Open EntryOver-separation is limited by sleeve

Surface engagement

concentrated at the tip

Closed EntryOver-separation is eliminated

Surface engagement is

consistent along the barrel

Normal force

(male contact in gray)

PosiBand®

Page 4: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 4

The PosiBand Design

The PosiBand external pressure element design fully separates the mechanical action from the electrical action of the connection. The pressure element performs the mechanical action by applying a force pressing the male pin against the inner female cavity achieving electrical connection along a long line of direct contact. The length of the line of interface can be varied therefore allowing to optimize by design the interface resistance of the connection.

Page 5: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 5

• Provides normal force on the male contact

• Spring tempered copper alloy

• Rugged and reliable

• Lower average insertion force...while meeting or exceeding performance requirements.

• Contact body does not require annealling

PosiBand: A Closer Look

PosiBand spring clipSpring Clip

Page 6: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 6

More electrical paths means less potential disruption due to vibration and corrosion

PosiBand: A Closer Look

Assembled Contact

Cross Section

Chamfer

Unbroken Ring

Electrical Pathis provided along the “floor” of the contact body

Spring Clip

Page 7: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 7

Size 20 PosiBand® Temperature Rise Curve

Low initial contact resistance of 4 milliohms maximum

TEMPERATURE RISE (ºC)

RA

TE

D C

UR

RE

NT

(AM

PS

)

Current Capacity, per UL 1977: 18 amps @ 2 contacts14 amps @ 6 contacts11 amps @ 15 contacts10 amps @ 25 contacts 9 amps @ 50 contacts

0

2

4

6

8

10

12

14

16

18

20 CONTACTSLOADED IN POSITIONS1 - 6

CONTACTSLOADED IN POSITIONS1 - 2

CONTACTSLOADED IN POSITIONS1 - 25

CONTACTSLOADED IN POSITIONS1 - 50

CONTACTSLOADED IN POSITIONS1 - 15

Page 8: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 8

Size 22 PosiBand® Temperature Rise Curve

Low initial contact resistance of 5 milliohms maximum

Current Capacity, per UL 1977: 12 amps @ 2 contacts 10 amps @ 6 contacts7.5 amps @ 26 contacts6.5 amps @ 62 contacts 5.0 amps @ 104 contacts

CONTACTSLOADED IN POSITIONS1 - 6

CONTACTSLOADED IN POSITIONS1 - 2

CONTACTSLOADED IN POSITIONS1 - 26

CONTACTSLOADED IN POSITIONS1 - 62

CONTACTSLOADED IN

POSITIONS1 - 104

0

2

4

6

8

10

12

14

TEMPERATURE RISE (ºC)

RA

TE

D C

UR

RE

NT

(AM

PS

)

Page 9: PosiBand...material compared to split-finger designs and a solid, unbroken ring at the entry point, which increases the mechanical robustness of the contact. • PosiBand has greater

THE SCIENCE OF CERTAINTY®

connectpositronic.com

Rev C — 9

Here’s what Engineers are saying

“I believe the PosiBand causes less digging/scraping to male contacts than the split-finger design, most notably when the male contact is made of soft metal.”

“Our report with resistance values after vibrations is very interesting, showing a significant reduction in resistance value consistently. Also, the plating (as associated with fretting) seems to have higher integrity after vibrations.”

“The PosiBand clip is shorter than the shrouded split-finger clip so it can fit in a more compact connector system.”