(0.61in)
55m
m
27,4
32m
m
63,9
23m
m
(2.5
1in
)
15,613mm
(0,9
6in
)
(2.1
6in
)
135mm
12
,50
0m
m1
2,0
67
mm
(5.31in)
(0.4
9in
)(0
.47
in)
cle
ara
nc
e
34
,6m
m
(1.3
6in
)
111mm
(4.371in)
ELECTRONIC CONTROL
and
A P P L I C A T I O N S
Characteristics• Easy interface• Highly customizable• Custom symbols on switches and display• Individual multicolor indicators• 13 key baklighted rubber keyboard• ABS board• Robust automotive standard connector• OLED graphic display 128x64px• Diagnostics menu• Parameter adjustment menu• Dual scale (ºF or ºC)
Fox is the modern family of Globus controllers,designed to bring comfort to the user
NOMINAL VOLTAGE
VOLTAGE RANGE 10 Vdc to 30 Vdc
MAXIMUM VOLTAGE 32 Vdc During 5min
MAXIMUM OUTPUT CURRENT 500mA
OUTPUT SHORT CIRCUIT PROTECTION Protected
REVERSE POLARITY PROTECTION Protected
OPERATION TEMPERATURE RANGE -40ºC to +70°C /-40ºF to +158ºF
STORAGE TEMPERATURE -40ºC ~ + 85°C /-40ºF ~ + 185ºF
TEMPERATURE SENSOR NTC 10KW / 25ºC/77ºF
PROTECTION DEGREE IP 54 Front Panel
CONNECTORS TYCO MATE-N-LOK
COMMUNICATION BUS CAN - SAE J1939 / ONE WIRE
CURRENT COMSUMPTIOM 50mA
12 Vdc to 24 Vdc
Technical Information
Optionals• CAN BUS / LIN BUS / ONE WIRE communication• PWM outputs• Bluetooth• Data Logger• Integrated or remote I/Os (using on ECU)• All functions CAN be customized
www.globuselectronics.com
Part Number GL-P6HGL001
HVAC+R CONTROLLER CONCEPT USING FRONT RUBBER PANEL AND OLED GRAPHIC DISPLAY
• 3 speed evaporator blower• Clutch output• Heating output• Fresh air output• Pressure switch input• Return temperature sensor input• External temperature sensor input• Cooling, heating and auto modes
ELECTRONIC CONTROL
GND
BLOWER FRESH AIR
EXTERNALFUSE
+-12/24VDC
CLUTCH CONDENSERFAN
HEATING
EXTERNALTEMP SENSOR
RETURNTEMP SENSOR
PRESSURESWITCH
V+
www.globuselectronics.com PT0094E REV. 01
Part Number GL-P6CGL001+MICGL001
ELECTRONIC CONTROL
CABIN CONTROLLER CONCEPT USING FRONT RUBBER PANEL AND OLED GRAPHIC DISPLAY
• 3 speed evaporator blower• Clutch output - Automatic control• Fresh air output• Pressure switch input• Return temperature sensor• Front and rear work light• Front and rear wiper• Front and rear washer• Extension ECU (GL-MICGL001) - one wire communication
GND
BLOWER FRESH AIR
EXTERNALFUSE
+-12/24VDC
CLUTCH CONDENSERFAN
GL-P6CGL001 GL-MICGL001
FRONT WASHER
FRONT WIPER
REAR WIPER
FRONT WORK LIGHT
REAR WORK LIGHT
V+
EXTERNALTEMP SENSOR
PRESSURESWITCH
ONEWIRE
V+
REARWASHER
MENU
www.globuselectronics.com PT0094E REV. 01
1
ELECTRONIC CONTROL
Part Number GL-P6HGL002
• Easy HMI Interface• CAN BUS communication• Customer designs owm software• Cooling, heating and auto modes• Fresh air control• 3 speed ventilation control
CAN
ECUCUSTOMER
CAN BUS (SAE - J1939)
NETWORK
CONTROLLER CONCEPT USING FRONT RUBBER PANEL AND OLED GRAPHIC DISPLAY
GND
EXTERNAL FUSE
+-12/24VDC
www.globuselectronics.com PT0094E REV. 01
23ºC+12/+24VDC
PRESSURESWITCH
SENSOR 2
SENSOR 1GND
OUTPUT 5OUTPUT 4OUTPUT 2OUTPUT 1OUTPUT 3
D + CAN H CAN L 1 WIRE
CAN OU 1 WIRE
Part Number GL-
CABIN CONTROLLER CONCEPT USING FRONT RUBBER PANEL AND OLED GRAPHIC DISPLAY
ELECTRONIC CONTROL
www.globuselectronics.com PT0094E REV. 01
• Vertical layout• 3 speed evaporator blower• Clutch output - Automatic control• Fresh air output• Pressure switch input• Return temperature sensor• Front and rear work light• Front and rear wiper• Front and rear washer• Extension ECU (GL-MICGL001) - one wire communication