Upload
theresa-robinson
View
245
Download
12
Embed Size (px)
Citation preview
PORTABLE GAS DETECTORS
GAS / FLAME DETECTION GAS / DUST MONITORING
Portable single gas detectors:
Explosimetres range Toximetres and Oxygenometres range
EX 2000 GDP 2000 EX 2000C
TX 2000 TX 2000 +
C 2000
RX 500Pump BP2000
PORTABLE EXPLOSIMETRES
POCKET SIZE:237 cm3
The 2000 range: DESCRIPTION
EX 2000C
PLUG IN / TOP MOUNTED SENSOR
LARGE DISPLAYWITH PICTOGRAMS
USERFRIENDLY KEYBOARD
CALIBRATION PLUG
BIG FLASHING LED
BUZZER
GDP 2000
HIGH PERFORMANCES
LONG BATTERY LIFE:
- 22h with « NimH »- and 30 hours with dry cell batteries
HIGH PERFORMANCES
CHARGERS:- simple charger (slow charge)=16h
max. - 12VDC charger (DC cable/slow
charge)= 16h max.- « intelligent » two position charger
(fast charge)= 4h max.
MANY FUNCTIONS
FRIENDLY DISPLAY PANEL:
MANY FUNCTIONSVISUAL AND AUDIO GAS ALARMS:- red light flashing- pulsed alarm=1 beep every 2sec.---> AL 1- pulsed alarm=1 beep every 1sec.---> AL 2
VISUAL AND AUDIO FAULT ALARMS:- red light lighting (continous)- battery and sensor faults
MANY FUNCTIONS
AUTO OPERATION STATUS :- auto test when switching on- auto diagnosis- confidence beep- battery and sensor faults:
pictograms displayed
CHARACTERISTICS
EX 2000To measure the explosive gas
concentration:- displays 0 - 100 % LEL
Detects all types of explosive gases
Can be programmed for a selected gas (manual procedure)2 gas alarms
EX 2000CTo measure the concentration (low or
high) of explosive gases:Detect and display low concentration « 0-
100% LEL » = explosimeterDetect and display high concentration
« 0-100%vol.)= catharometerOnly one detection sensorAutomatic switch over of range (catalytic
or catharomic)
GDP 2000To discriminate between natural gas and
other explosive gas and to DISPLAY the gas concentration
Detect all types of explosive gases with discrimination
displays simple messages for the user: NATURAL GAS or FLAMMABLE GAS
with the gas concentration detected in % LEL.
ACCESSORIES 2000
Chargers :220VAC or 12VCCcalibration kitsampling kittool kitprotective leather kitelectric pump
APPROVALS:2000 range- EEx iad IIC T4 INERIS 98 D 5022 X
surface
- EEx iad I INERIS 98 Y 3001 X mine
with the north American certification:
- ATEX
- Gas distribution companies
- Telecommunications
- Fire brigades
- wastewater stations ….
ELECTRIC PUMP BP 2000
Small sizelight weightEasy to operate (ON/OFF)
allows the detection of gases where it ’s difficult to access.
BP 2000 : description
gas inlet
gas outlet
pression detector
LED + buzzer
electric Pump
Simple charger connection
Bloc of batteries
ELECTRIC PUMP: BP 2000
powered by 3 dry batteries LR6 (1,5V) or rechargeable batteries NiMH
Autonomy:mini 8Hcharger CR2002 =max. charging time: 4Hsimple charger (AC bloc)=max. charging time : 16H
ELECTRIC PUMP BP 2000
Indications : battery defaultflow alarm (pump)(integreted pressure detector). too low pressure(pump used…). too high pressure(outlet closed…)visual and audible alarms (30s to 1mn).
ELECTRIC PUMP BP 2000
T° of using : 10° à 45°CHygrometry: 5% RH à 90%RHindex of protection: IP 66 (exept inlet/outlet of pump)
ELECTRIC PUMP BP 2000
certifications:II 1 GD EEx ia IIC T3 ou T4 (dry batt.)I M1EEx ia Iin accordance with the regulations: CE, CEM et ATEX.
Example: BP 2000 and EX 2000
multigas portable detectors :
MX 2000MX 2000
MX 21 plusMX 21 plus
BM 22 plusBM 22 plus
MX 2100 BM 25
= Certified « ATEX »
MX 2100S
portable multigas detectors:
C 2000
MX 2100
BM 25
MX2100S
ia
Multigas : MX 2100(S)
5 gas simultaneous detectionup to 6 measurement ranges with MX 2100.
4 gas simultaneous detection with MX 2100S .
Multigas : MX 2100(S)
( weight)
Multigas : MX 2100(S)
characteristics
cells
Anti-skid side
Graphical LCD
keypadclip
Carrier belt
95db at 30cm
MX 2100(S) : power supply
*continuouslyType operating time operating time without electric pump with electric* pump
alkaline batteries 24/13 hours 10/7 hoursAAA
NiMH battery 16/9 hours 6/4.30 hours Pack
MX 2100(S) : tactile pad
- Audible alarm acknowledgement- display mode
- LCD: backlighting- parameter display- display of menus
ON/OFF/validation
MX 2100(S) : graphical display
- graphical display for easier measurement readout
- simultaneous display of 5 measurements with MX2100
and 4 measurements with MX2100S
- manual or automatic backlighting
- parameter display.
MX 2100(S):all sensors are pre-calibrated, smart and interchangeable (outside danger area)
big cell
small cells
explo Cell
Standard configuration4 gases detected
Examples of configuration: MX2100
- toxic cells or
- oxygen cell : 1 year life
- catalytic explo cell : 100% LEL or
- explo/catharo cell : 100% LEL/100%volume
- or oxygen cell : 2 years life
- toxic cells (CO/H2S ; SO2 ; CL2 ; CO2/IR)
Examples of configuration: MX2100S
- toxic cells: CO or H2S or
- catalytic explo cell : 100% LEL
- oxygen cell : life time = 2 ans
- toxic cell SO2 or - oxygen cell : 1 year of life time
MX 2100(S): smart blocks
MX 2100(S) : alarms and histograms
InstantaneousSTEL / TLV data
MX 2100(S) : into details
gas alarms :high and low
thresholds for oxygen
1 low threshold for the catharometric channel
types of alarms: alarme 1 : every sec. alarme 2: every 500ms
trouble alarms : 20% over alarm in negative
mode 120% over alarm in tox and
oxygen mode 100% over alarm in explo.
mode.
types of alarms:continous audible
signal common to all channels.
MX 2100(S) : User-friendliness
**variable storage intervals: between 1 sec. and 1 hour- 200000 records (events and measurements)- FIFO
memory saved bya lithium battery
Stored events and measurements
The data-logging function
MX 2100 : User-friendliness
* * pre-programmed list of names( 32 names)
Patrol function
MX 2100 : User-friendliness
Auto zero: on demand
or as a charger output (option)
operating check : audible bip (interval can be set by
Oldham).
Self-diagnostics and any anomalies indication
accessories
Plastic protective case
- charging time = 3 hours max.
Smart charger
Electric pump
Sampling kit
MX2100(S) : portable TEST BENCH « CALCHECK »
MX2100(S) : test terminal
-reference gas injection system to trigger the alarms
- Le MX 2100(S) detects the presence of the terminal anddisplay any faulty channels
- fitted with one or two cylinders.
( 50% LEL CH4 / 15% O2 / 100ppm CO / 1 % CO2 / 20 ppm H2S )
Printout of data
Serial cable (RS232)
Charging or sampling Block
IR module
- Directly linked to a PC:
communication software COM 2100
Serial cable
Charging or sampling Block
IR module
The MX2100(S) can be linked to a PCvia a IR port:
communication software COM 2100
Supervise and maintain the device:
text display of leasurements and channel parameters
troubleshooting if there is a problem
programming of the detector and measurement channel
option management channel calibration via automated
drop-down menu printout of encrypted status sheet
and test sheet management,display and printout
of stored events and measurements
protection by password.
Conformity with ATEX directives:certification
- As per explosive atmospheres (ATEX) directive : 94/9/EC (a very high safety level).
- As per electromagnetic compatibility directive 89/336/EC, standard EN 50270.
portable multigas detectors:
C 2000
MX 2100
BM 25
MX2100S
ISC gas portable detectors
Monitoring Choices
• CO (0 – 1500 ppm)
• H2S (0 – 500 ppm)
– 0.1 ppm resolution
• O2 (0 – 30% by vol)
• NO2 (0 – 150 ppm)
• SO2 (0 – 150 ppm)
www.GasBadge.com
M40
www.GasBadge.com
VX500
PID