CADDO-BOSSIER PARISHES PORT COMMISSION APRIL 2019 PORT RCC PHYSICAL SECURITY PROJECT A1 MATERIAL INDEX DRAWING INDEX ARCHITECTURAL VICINITY MAP SYMBOLS LEGEND A1 A2 A3 ABBREVIATIONS 5A OF Job Drawn Scale Date KEVIN BRYAN ARCHITECT, L. L. C 712 TEXAS STREET SHREVEPORT, LOUISIANA 71101 WORK 318-673-9980 FAX 318-673-9982 [email protected]REVISIONS ARCHITECT PROJECT 6000 DOUG ATTAWAY BLVD. SHREVEPORT, LA 71115 PROJECT INFO APRIL 2019 AS SHOWN SHEET CADDO-BOSSIER PARISHES PORT COMMISSION PORT RCC PHYSICAL SECURITY PROJECT PROJECT NO. ENG.19.013 A4 A5 SITE MAP 6000 DOUG ATTAWAY BLVD. SHREVEPORT, LOUISIANA 71115 PROJECT LOCATION PROJECT NO. ENG.19.013
PORT RCC PHYSICAL SECURITY PROJECT - Caddo-Bossier RCC... · 2019-06-03 · project 6000 doug attaway blvd. shreveport, la 71115 project info april 2019 as shown sheet port rcc physical
1601 BARRIER GATE BY DOORKING OR EQUAL. USES 12HP CONTINUOUS DUTY MOTOR. 115, 230, OR 460 VAC BUT 230 AND 460 VOLT WILL REQUIRE A STEP DOWN POWER TRANSFORMER TO ACHIEVE 115 VOLT OPERATING VOLTAGE. 40:1 GEAR-BOX RUNNING IN A CONTINUOUS OIL BATH. ARM ROTATES 90° IN APPROXIMATELY 1.5SECONDS. MUST COMPLY WITH FEDERAL REGULATION UL325 ADDITIONAL OPTIONS TO PRICE ARE AS FOLLOWS: -12-FOOT BREAK-A-WAY ARM KIT (ALUMINUM) -PLUG-IN LOOP DETECTORS -FOAM PADDING FOR ALUMINUM ARM -DC POWERED CONVENIENCE OPEN -MANUAL CRANK KIT -SET OF PHOTO CELLS
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
EXISTING JUNCTION BOX IN PLACE
AutoCAD SHX Text
J
AutoCAD SHX Text
EXIST. 1"C TO PANEL "HG" FOR MOTORIZED GATE
AutoCAD SHX Text
EXIST. 1"C TO PANEL "HG" FOR MOTORIZED GATE
AutoCAD SHX Text
GATE OPERATOR
AutoCAD SHX Text
W/ SWING GATE
AutoCAD SHX Text
12'-0"L ARM
AutoCAD SHX Text
EXIST. 3/4" CONDUIT
AutoCAD SHX Text
2'-0"
AutoCAD SHX Text
NOTE: PROVIDE 5" THICK CONCRETE BENEATH EA. GATE OPERATOR AND CODE OPENER
AutoCAD SHX Text
IF SHEET IS LESS THAN 30" x 42", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.
AutoCAD SHX Text
.
AutoCAD SHX Text
N
AutoCAD SHX Text
THE OVERHEAD COILING GRILL OR CONTROLS FOR OPERATING THE OVERHEAD COILING GRILL SHALL HAVE A COMPONENT INCLUDED THAT WILL TRIGGER OPENING OF THE DOOR UPON RADIO SIGNAL FROM FIRE DEPARTMENT OR POLICE. CONTRACTOR TO PURCHASE AND INSTALL A CLICK2ENTER” DEVICE THAT ALLOWS FOR ACCESS TO SITE. DEVICE THAT ALLOWS FOR ACCESS TO SITE. CONTRACTOR SHALL PURCHASE AND INSTALL TWO - ONE FOR THE OVERHEAD COILING GRILL AND ONE FOR THE GUARD ARMS AT THE ENTRANCE TO THE PARKING LOT. CONTRACTOR HAS OPTION TO PURCHASE ONE CLICK2ENTER DEVICE TO CONTROL BOTH, BUT ONLY IF THE CONTRACTOR CAN ASSURE THAT ONE DEVICE CAN CONTROL BOTH. PROVIDE POWER TO EACH DEVICE AS NEEDED. CONTRACTOR TO PURCHASE THE CLICK2ENTER DEVICE THAT IS SPECIFICALLY MADE TO WORK IN THE SHREVEPORT REGION. VERIFY PRIOR TO PURCHASE AND INSTALLATION. VISIT WWW.CLICK2ENTER.NET TO PURCHASE. WWW.CLICK2ENTER.NET TO PURCHASE. TO PURCHASE.
AutoCAD SHX Text
GENERAL CONTRACTOR SHALL PURCHASE AND INSTALL TWO SURFACE MOUNTED 3200 SERIES KNOX BOXES FROM THE KNOX BOX COMPANY. CONTRACTOR TO ENSURE THE PURCHASE IS SPECIFICALLY MADE FOR THE SHREVEPORT REGION OR SAID BOXES WILL NOT FUNCTION FOR THIS LOCALE. ONE BOX SHALL BE WALL MOUNTED AT OR AROUND THE DOORS LEADING INTO THE GROUND FLOOR OF THE OFFICE FROM THE PARKING GARAGE. THE OTHER BOX SHALL BE RAIL MOUNTED NEAR THE MAIN FRONT DOORS OF THE BUILDING. EXACT LOCATIONS OF BOTH BOXES SHALL BE BY ARCHITECT AND / OR OWNER. VERIFY PRIOR TO INSTALLATION. VISIT WWW.KNOXBOX.COM TO PURCHASE. WWW.KNOXBOX.COM TO PURCHASE. TO PURCHASE.
PROVIDE 8"X8"X "T 14"T STEEL BASE PLATE W/ "DIA. 38"DIA. HILTI ANCHORS OR AS RECOMMENDED BY MANUFACTURER
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
NEW 5"THICK CONCRETE PAVING. PROVIDE #5 BARS EA. WAY 12"O.C. AND DOWEL INTO EXISTING CONCRETE W/ #5 BARS 12"DEEP. PRIOR TO POURING CONCRETE PROVIDE SELECT COMPACTED FILL AS PER CODE FOR PAVING.
AutoCAD SHX Text
NEW 4" THICK CONCRETE SIDEWALK. PROVIDE W.W.F. IN CENTER OF CONCRETE PRIOR TO POURING. SUBGRADE MUST BE PROPERLY COMPACTED
AutoCAD SHX Text
NEW 42"W
AutoCAD SHX Text
SECURITY DOOR
AutoCAD SHX Text
EXISTING SPRINKLER PIPE ABOVE AT THIS LOCATION WILL NEED TO BE RE ROUTED AS INDICATED-SEE E/A3
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
PROVIDE FACE MTD. MOTOR AT THIS LOCATION
AutoCAD SHX Text
REMOVE THIS SECTION OF SPRINKLER PIPE
AutoCAD SHX Text
E
AutoCAD SHX Text
A3
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
SAW CUT CONCRETE CURB AND SIDEWALK BACK JUST ENOUGH TO INSTALL DOOR GUIDES SO THAT THE DOOR FUNCTIONS PROPERLY. POUR NEW CONCRETE BACK LEVEL WITH EXISTING DRIVEWAY PAVEMENT
AutoCAD SHX Text
EXISTING CONCRETE COLUMN
AutoCAD SHX Text
FACE OF WALL MTD. DOOR GUIDE
AutoCAD SHX Text
8'-0 " 12" CLEAR OPG. HEIGHT
AutoCAD SHX Text
EXISTING CONCRETE BEAM
AutoCAD SHX Text
FACE OF WALL MTD. DOOR GUIDE
AutoCAD SHX Text
DOOR MANUFACTURER PROVIDE ADDITIONAL COVER PLATE TO MATCH THE REST OF DOOR HOOD
AutoCAD SHX Text
D
AutoCAD SHX Text
A3
AutoCAD SHX Text
PROVIDE HU517 BOX HINGES TOP AND BOTTOM
AutoCAD SHX Text
PROVIDE PALE W/ " #9 FLAT 34" #9 FLAT EXPANDED METAL
AutoCAD SHX Text
FIN. FLOOR 0'-0"
AutoCAD SHX Text
PROVIDE IMP-II GAUNTLET 8' HEADER KIT F/PRE-HUNG GATE
AutoCAD SHX Text
PROVIDE HARDWARE SET 5 - VON DUPRIN 99 SERIES EXIT DEVICE - VON DUPRIN 996 TRIM HANDLE - LCN 4040XPSRI PARALLEL ARM CLOSER
AutoCAD SHX Text
SECURE SIDE
AutoCAD SHX Text
SECURE SIDE
AutoCAD SHX Text
GATE SHOWN WITH RIGHT HAND OUTSWING
AutoCAD SHX Text
PROVIDE 3" 12GA GALVANIZED JAMB (STANDARD) DIRECT BURY TO 36" DEPTH
AutoCAD SHX Text
PROVIDE 1 3/4" 14GA GALVANIZED GATE (STANDARD)
AutoCAD SHX Text
PROVIDE HEAVY DUTY McKINNEY HINGES (X3) (STANDARD)
AutoCAD SHX Text
4" I-BEAM
AutoCAD SHX Text
IMPASSE-II RAIL
AutoCAD SHX Text
2 3/4" X 14GA. PALE
AutoCAD SHX Text
NEW 42"W
AutoCAD SHX Text
SECURITY DOOR
AutoCAD SHX Text
4" I-BEAM
AutoCAD SHX Text
IMPASSE-II RAILS
AutoCAD SHX Text
2 3/4" X 14GA. PALE
AutoCAD SHX Text
FENCE POSTS INSTALLED WHERE NO CONCRETE EXISTS AT GRADE WILL REQUIRE A CONCRETE FOOTING PER MANUFACTURER'S RECOMMENDATION-MANUFACTURER TO DETERMINE ACTUAL STEEL PIPE DIMENSION REQUIREMENTS NOTE: CONNECTION BETWEEN FENCE PANELS AND STEEL POSTS WILL BE AS PER MANUFACTURER'S RECOMMENDATION
AutoCAD SHX Text
FENCE POSTS INSTALLED WHERE NO CONCRETE EXISTS AT GRADE WILL REQUIRE A CONCRETE FOOTING PER MANUFACTURER'S RECOMMENDATION-MANUFACTURER TO DETERMINE ACTUAL STEEL PIPE DIMENSION REQUIREMENTS NOTE: CONNECTION BETWEEN FENCE PANELS AND STEEL POSTS WILL BE AS PER MANUFACTURER'S RECOMMENDATION
AutoCAD SHX Text
4" I-BEAM
AutoCAD SHX Text
IMPASSE-II RAILS
AutoCAD SHX Text
2 3/4" X 14GA. PALE
AutoCAD SHX Text
EXISTING OR NEW 5" THICK CONCRETE PAVING
AutoCAD SHX Text
EXISTING CONCRETE CEILING
AutoCAD SHX Text
NOTE: CONNECTION BETWEEN FENCE PANELS AND STEEL POSTS WILL BE AS PER MANUFACTURER'S RECOMMENDATION
AutoCAD SHX Text
±3"DIA. EXIST. SPRINKLER PIPETO BE RE ROUTED THRU 6" OPEN SPACE ABOVE NEW DOOR
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
REFER TO F/A3
AutoCAD SHX Text
REFER TO F/A3
AutoCAD SHX Text
REFER TO F/A3
AutoCAD SHX Text
IF SHEET IS LESS THAN 30" x 42", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.