16
Polymeric SPE Successful Bioanalytical Sample Preparation Without the Dry Down NEW Method Development and Peptide Screening Plates Increase sensitivity Process small or limited sample volumes Save time and reduce costs Reduce loss of challenging analytes Microelution 96-Well SPE Plates

Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

Polymeric SPE

Successful Bioanalytical Sample Preparation

Without the Dry DownNEW Method Development and Peptide Screening Plates

• Increase sensitivity

• Process small or limited sample volumes

• Save time and reduce costs

• Reduce loss of challenging analytes

Microelution 96-Well SPE Plates

Page 2: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

2

5 Simple Steps for Clean Samples

Solid Phase Extraction (SPE) is an effective technique for cleaning up and concentrating samples prior to UHPLC/HPLC or GC analysis. Available in several chemistries, the SPE sorbent selectively targets your analytes of interest, allowing interferences and impurities to be washed away by following 5 easy steps.

A conditioning step activates the SPE sorbent

An equilibration solvent prepares the sorbent for interaction with your sample

Target analytes are selectively targeted and bound to the SPE sorbent

Interferences are washed away

An elution solvent breaks the bond between the SPE sorbent and your target analytes, allowing them to be collected for further analysis

Your sample is now clean and concentrated

Step 1. Condition

Step 2. Equilibrate

Step 3. Load Sample

Step 4. Wash Away Impurities

Step 5. Collect Analytes of Interest

Interferences

Target Analytes

Interferences

Target Analytes

Solid Phase Extraction (SPE) Basics

SPE Is Easy!Turn to page 4 to learn how Strata-X Microelution 96-Well SPE Plates can further improve your work.

© 2016 Phenomenex, Inc. All rights reserved.

Phenomenex l WEB: www.phenomenex.com

Page 3: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

3

Microelution SPE is Faster and More Sensitive pp. 4-5

Skip the Dry Down Step

m Increase Throughput p. 6

m Reduce the Risk of Analyte Loss p. 7

Easily Process Samples p. 8

Applications:

m Reliable Peptide Analysis p. 9

m Ultra Sensitive Pharmaceutical Analysis p. 10

m Reproducible Clinical Research Analysis p. 11

m Rapid Analysis of Drugs of Abuse p. 12

Method Development / Web Tools / Seminars p. 13

Ordering Information pp. 14-15

than Traditional SPE

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Page 4: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

4

Microelution SPE is Faster and More Sensitive

Not amenable to small or limited sample volumes

Concentration of target analytes is diluted

Dry down is required to increase sensitivity, adding time and cost

Step 1. Condition

Step 2. Equilibrate

Step 3. Load Sample

Step 4. Wash

Step 5. Elute

Step 6. Dry Down

and Recon-stitute

Traditional 10 mg SPE

200 µL

200 µL

100+ µL

200-400 µL

200 µL

~30-60 EXTRA minutes

10 mg

10 mg

10 mg

10 mg

10 mg

Thermolabile or unstable analytes can be lost during this step

Phenomenex l WEB: www.phenomenex.com

Page 5: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

5

Microelution SPE is Faster and More Sensitive

Step 1. Condition

Step 2. Equilibrate

Step 3. Load Sample

Step 4. Wash Away Impurities

Step 5. Elute

Process small or limited sample volumes without constraints

At least 8x more sensitive than traditional 10 mg SPE!

Save 30 or more minutes per 96-well plate!

Step 1. Condition

Step 2. Equilibrate

Step 3. Load Sample

Step 4. Wash

Step 6. Dry Down and Recon-stitute

Strata-X Microelution SPE

200-400 µL

200 µL

200 µL

25 µL

sample volumes as low as

10 µL

NOT REQUIRED

Save on labor costs, do more in less time

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Page 6: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

6

Increase Throughput

Save 30 or more minutes per 96-well plate by eliminating timely dry down and reconstitution steps.

View the Case Study!www.phenomenex.com/Microelution

Traditional 10 mg SPE

Strata®-X MicroelutionSPE

30 Minutes

No Dry Down!60 Minutes

Total

Processing Time

768 Samples

Throughput(in 8 hours) 1,536

Samples

DOUBLE Your Throughput

REDUCE Cost per Sample!

Phenomenex l WEB: www.phenomenex.com

Page 7: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

7

Many target analytes such as peptides and thermolabile compounds can be lost during dry down steps. Stop risking analyte loss and skip the dry down step without losing sensitivity.

Strata-X 96-Well SPE Plate, 10 mg/well Strata-X Microelution 96-Well SPE Plate, 2 mg/well

Condition 400 µL Methanol 200 µL MethanolEquilibrate 400 µL Water 200 µL WaterLoad 400 µL diluted serum (200 µL serum diluted

1:1 with 4 % Phosphoric acid in water)400 µL diluted serum (200 µL serum diluted 1:1 with 4 % Phosphoric acid in water)

Wash 1 400 µL 2 % Formic acid in water 200 µL 2 % Formic acid in waterWash 2 400 µL 20 % Acetonitrile in water 200 µL 20 % Acetonitrile in waterElute 2x 175 µL Trifluoroacetic acid/Acetonitrile/Water

(1:74:25)2x 25 µL Trifluoroacetic acid/Acetonitrile/Water (1:74:25)

Dry Down Dry down under a gentle stream of Nitrogen and reconstitute in 50 µL Trifluoroacetic acid/ Acetonitrile/Water (1:74:25)

NOT REQUIRED

Inject 10 µL 10 µL

Ap

p ID

229

96 a

nd 2

2997

0 0.5 11 1.5 2 2.5 3 3.5 4 4.5 5 5.5 min0.0

1.0e4

2.0e4

3.0e4

4.0e4

5.0e4

6.0e4

7.0e4

8.0e4

9.0e4

1.0e5

1.1e5

1.2e5

1.3e5

1.4e5

1.5e5

1.6e5

1.7e5

22996

Inte

nsity

, cp

s

0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 min

1.0e4

2.0e4

3.0e4

4.0e4

5.0e4

6.0e4

7.0e4

8.0e4

9.0e4

1.0e5

1.1e5

1.2e5

1.3e5

1.4e5

1.5e5

1.6e522997

Inte

nsity

, cp

s

Column: Kinetex® 5 µm C8Dimensions: 50 x 4.6 mm

Part No.: 00B-4608-E0Mobile Phase: A: 0.1 % Formic acid in Water

B: 0.1 % Formic acid in MethanolGradient: Time (min) % B

0.003.004.004.016.00

1090901010

Flow Rate: 600 µL/minTemperature: Ambient

Detection: MS/MS, Triple Quad™ 4500 (SCIEX), ESI+Sample: DALDA C8 (peptide), spiked at 10 ng/mL

10 mg SPE • ~50 % loss is observed after dry down step• Absolute Recovery: 50 %• % CV (N=6): 10.5

Microelution SPE • Skip the dry down and increase recovery• Absolute Recovery: 95 %• % CV (N=6): 5.7

1. CNS Delivery and Pharmacokinetic Evaluations of DALDA Analgesics Peptide Analog Administered in Nano-Sized Oil-in-Water Emulsion Formation. Shah L., Gattacceca F. and Amiji MM. Pharm Res (2014) 31:1315-1324.2. Analgesic Efficacy and Safety of DALDA Peptide Analog Delivery to the Brain using Oil-in-Water Nanoemulsion Formation. Shah L., Kulkarni P., Ferris C., and Amiji MM. Pharm Res. (2014) 31:2724-2734.

Reduce Analyte Loss

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Page 8: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

8

Easily Process Samples

Strata®-X Microelution 96-well SPE plates are compatible with standard vacuum manifolds, positive pressure manifolds, and liquid handling systems, making it even easier to process your samples.

High-Throughput, Hands-Free Liquid Handling SystemsUse the dimensions outlined below to program your liquid handling system.

measured in mm

127.76

85.4

814.38

11.1

76

9.00

9.

00

99.00

63

.00

39

.009

46

.17

0.118

Cost Effective Benchtop Processing

96-Well Plate Vacuum ManifoldPart No. AH0-8950

Presston™ 100 Positive Pressure Manifold Part No. AH0-9334

Phenomenex l WEB: www.phenomenex.com

Page 9: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

9

Absolute Recovery of Goserelin at 5 ng/mL

Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well Part No. 8M-S035-4GA

Condition 200 µL MethanolEquilibrate 200 µL WaterLoad 400 µL diluted serum (200 µL serum diluted 1:1 with 4 %

Phosphoric acid in water)

Wash 1 200 µL 5 % Ammonium hydroxide in waterWash 2 200 µL 20 % Acetonitrile in waterElute 2x 25 µL Trifluoroacetic Acid/Acetonitrile/Water (1:74:25)Inject 2 µL

Application

Reliable Peptide Analysis

Peptide RT (min) % Absolute Recovery % CV (N=10)

Goserelin 2.27 98 5.8

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min0.0

5000.0

1.0e4

1.5e4

2.0e4

2.5e4

3.0e4

3.5e4

4.0e4

4.5e4

5.0e4

5.5e4

6.0e4

6.5e4

7.0e4

7.5e4

8.0e4

8.5e4

9.0e4

22995

Inte

nsity

, cp

s

Ap

p ID

229

95

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Column: Aeris™ WIDEPORE 3.6 µm XB-C18Dimensions: 50 x 2.1 mm

Part No.: 00B-4482-ANMobile Phase: A: 0.1 % Formic acid in Water

B: 0.1 % Formic acid in MethanolGradient: Time (min) % B

0.003.004.004.016.00

1095951010

Flow Rate: 600 µL/minTemperature: Ambient

Detection: MS/MS, Triple Quad™ 4500 (SCIEX), ESI+

Page 10: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

10

Strata®-X-C 96-Well SPE Plate, 10 mg/well Strata-X-C Microelution 96-Well SPE Plate, 2 mg/well

Condition 500 µL Methanol 200 µL MethanolEquilibrate 500 µL Water 200 µL WaterLoad 750 µL diluted serum (375 µL serum diluted

1:1 with 4 % Phosphoric acid in water)750 µL diluted serum (375 µL serum diluted 1:1 with 4 % Phosphoric acid in water)

Wash 1 500 µL 2 % Formic acid in water 200 µL 2 % Formic acid in waterWash 2 500 µL Methanol 200 µL MethanolElute 375 µL (3x 125 µL) 5 % Ammonium hydroxide

in Acetonitrile/Methanol (60:40)25 µL 5 % Ammonium hydroxide in Acetonitrile/ Methanol (60:40)

Inject 1 µL 1 µL

Application

Ultra Sensitive Pharmaceutical Analysis

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min0.0

5.0e4

1.0e5

1.5e5

2.0e5

2.5e5

3.0e5

3.5e5

4.0e5

4.5e5

5.0e5

5.5e5

6.0e5

6.5e5

7.0e5

7.5e5

8.0e5

8.5e5

9.0e5

9.5e5

22983

Inte

nsity

, cp

s

Ap

p ID

229

83 a

nd 2

2985

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min0.0

5.0e4

1.0e5

1.5e5

2.0e5

2.5e5

3.0e5

3.5e5

4.0e5

4.5e5

5.0e5

5.5e5

6.0e5

6.5e5

7.0e5

7.5e5

8.0e5

8.5e5

9.0e5

9.5e522985

Inte

nsity

, cp

s

Procaine (1 ng/mL) Microelution SPE 15× More Concentrated!

10 mg SPE

Ap

p ID

229

82 a

nd 2

2984

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min0.0

5.0e4

1.0e5

1.5e5

2.0e5

2.5e5

3.0e5

3.5e5

4.0e5

4.5e5

5.0e5

5.5e5

22982

Inte

nsity

, cp

s

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min0.0

5.0e4

1.0e5

1.5e5

2.0e5

2.5e5

3.0e5

3.5e5

4.0e5

4.5e5

5.0e5

5.5e5

Inte

nsity

, cp

s

Timolol (1 ng/mL)Column: Kinetex® 2.6 µm Biphenyl

Dimensions: 50 x 2.1 mmPart No.: 00B-4622-AN

Mobile Phase: A: 0.1 % Formic acid in WaterB: 0.1 % Formic acid in Acetonitrile

Gradient: Time (min) % B0.000.503.003.503.515.50

55959555

Flow Rate: 500 µL/minTemperature: Ambient

Detection: MS/MS, API 5000™ (SCIEX)

10 mg SPE

Microelution SPE 15× More Concentrated!

Phenomenex l WEB: www.phenomenex.com

Page 11: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

11

Strata®-X-C 96-Well SPE Plate, 10 mg/well Strata-X-C Microelution 96-Well SPE Plate, 2 mg/well

Condition 500 µL Methanol 200 µL MethanolEquilibrate 500 µL Water 200 µL WaterLoad 750 µL diluted serum (375 µL serum diluted

1:1 with 4 % Phosphoric acid in water)750 µL diluted serum (375 µL serum diluted 1:1 with 4 % Phosphoric acid in water)

Wash 1 500 µL 2 % Formic acid in water 200 µL 2 % Formic acid in waterWash 2 500 µL Methanol 200 µL MethanolElute 375 µL (3x 125 µL) 5 % Ammonium hydroxide

in Acetonitrile/Methanol (60:40)25 µL 5 % Ammonium hydroxide in Acetonitrile/ Methanol (60:40)

Inject 1 µL 1 µL

Application

Absolute Recovery of 7 Antipsychotics at 25 ng/mL

Reproducible Clinical Research Analysis

Strata-X-C Microelution 96-Well SPE Plate, 2 mg/well Part No. 8M-S029-4GA

Condition 200 µL MethanolEquilibrate 200 µL WaterLoad 400 µL diluted plasma (200 µL plasma diluted 1:1 with 4 %

Phosphoric acid in water)

Wash 1 200 µL 2 % Formic acid in waterWash 2 200 µL MethanolElute 2x 25 µL 5 % Ammonium hydroxide in Acetonitrile/

Methanol (60:40)Inject 2 µL

Antipsychotics RT (min) % Absolute Recovery Recovery % CV (N=4)

Olazepine 2.7 99 6.9

Norclozapine 3.9 91 7

Clozapine 4.16 94 4

9-OH Risperidone 4.28 88 6.6

Risperidone 4.55 99 6

Norquetiapine 4.57 70 5.5

Quetiapine 4.73 90 2.7

22993

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 min0.0

1.0e5

2.0e5

3.0e5

4.0e5

5.0e5

6.0e5

7.0e5

8.0e5

9.0e5

1.0e6

1.1e6

1.2e6

1.3e6

1.4e6

1.5e61.6e6

1

2

34

5

6

7

Inte

nsity

, cp

s

Ap

p ID

229

93

Column: Kinetex® 2.6 µm BiphenylDimensions: 50 x 2.1 mm

Part No.: 00B-4622-ANMobile Phase: A: 0.1 % Formic acid in Water

B: 0.1 % Formic acid in MethanolGradient: Time (min) % B

0.005.005.505.518.00

5959555

Flow Rate: 500 µL/minTemperature: Ambient

Detection: MS/MS, Triple Quad™ 4500 (SCIEX)

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Page 12: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

12

Application

Absolute Recovery of 5 Amphetamines

Strata®-X-C Microelution 96-Well SPE Plate, 2 mg/well Part No. 8M-S029-4GA

Condition 200 µL MethanolEquilibrate 200 µL WaterLoad 400 µL diluted urine (200 µL urine diluted 1:1 with water)Wash 1 200 µL 2 % Formic acid in waterWash 2 200 µL MethanolElute 2x 25 µL 5 % Ammonium hydroxide in Acetonitrile/Methanol (60:40)Inject 2 µL

Amphetamines Concentration (ng/mL) (25 % below SAMHSA cut off)

RT (min) % Absolute Recovery % CV (N=4)

Amphetamine 125 1.83 82 13.1

Methamphetamine 125 2.12 107 15.1

MDA 62.25 2.15 106 4.2

MDMA 62.25 2.36 99 15.7

MDEA 62.25 2.53 108 10.5

Rapid Analysis of Drugs of Abuse

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 min0.0

5000.0

1.0e4

1.5e4

2.0e4

2.5e4

3.0e4

3.5e4

4.0e4

4.5e4

5.0e4

5.5e4

6.0e4

6.5e4

7.0e4

7.5e47.8e4

22986

Inte

nsity

, cp

s

Ap

p ID

229

86

Column: Kinetex® 2.6 µm BiphenylDimensions: 50 x 2.1 mm

Part No.: 00B-4622-ANMobile Phase: A: 0.1 % Formic acid in Water

B: 0.1 % Formic acid in MethanolGradient: Time (min) % B

0.003.004.004.016.00

1095951010

Flow Rate: 500 µL/minTemperature: Ambient

Detection: MS/MS, Triple Quad™ 4500 (SCIEX)

Phenomenex l WEB: www.phenomenex.com

Page 13: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

13

Column: Kinetex® 2.6 µm BiphenylDimensions: 50 x 2.1 mm

Part No.: 00B-4622-ANMobile Phase: A: 0.1 % Formic acid in Water

B: 0.1 % Formic acid in MethanolGradient: Time (min) % B

0.003.004.004.016.00

1095951010

Flow Rate: 500 µL/minTemperature: Ambient

Detection: MS/MS, Triple Quad™ 4500 (SCIEX)

Method Development / Web Tools / Seminars

Strata-X Method Development Plate (Part No.: KS0-9529) • Strata-X-C (3 wells) screening for basic analytes • Strata-X-AW (3 wells) screening for strong acidic analytes • Strata-X-CW (3 wells) screening for strong basic analytes • Strata-X-A (3 wells) screening for acidic analytes

Strata-X Peptide Screening Plate (Part No.: KS0-9528) • Strata-X-CW (6 wells) • Strata-X-A (6 wells)

Strata-X Method Development Microelution 96-Well PlatesEasily tests different sorbents for your unique peptide and small molecules using a single 96-well plate.

Learn more about method development plates: www.phenomenex.com/MicroelutionMethods

Complimentary Seminars and WebinarsDoes your lab need to become SPE experts? Schedule a complimentary, customized on-site seminar. Let us know what your challenges are and we can put together a presentation to help you solve them. If you don’t have time for us to visit, we can hold online trainings, or view our On-Demand Webinars.

Schedule a Seminar Now: [email protected]

Watch an On-Demand Webinar

m Method development

m Sorbent selection

m Troubleshooting

www.phenomenex.com/webinars

Need Additional Method Development Help?Create a Customized SPE MethodUse our SPE Method Development Tool to create a method in under 1 minute.

www.phenomenex.com/MDTool

Find More Web Tools at: www.phenomenex.com/webtools

Wells 1-3 Strata-X-C Screening

basic analytes

Wells 7-9 Strata-X-CW Screening strong basic analytes

Wells 4-6 Strata-X-AW Screening strong acidic analytes

Wells 10-12 Strata-X-A Screening

acidic analytes

Strata-X-C Strata-X-AW Strata-X-CW Strata-X-A

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Page 14: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

14

Part No. Description UnitKS0-9528 Strata-X Peptide Screening

Strata-X-CW 2 mg/well (6 rows) Strata-X-A 2 mg/well (6 rows)

ea

KS0-9529 Strata-X Method DevelopmentStrata-X-C 2 mg/well (3 rows) Strata-X-AW 2 mg/well (3 rows) Strata-X-CW 2 mg/well (3 rows) Strata-X-A 2 mg/well (3 rows)

ea

Ordering Information

My Target Analytes Are:

Your Strata-X Microelution Product and Sorbent Chemistry Part No. Price (ea)

Strong Bases(pKa >10)

8M-S035-4GA

Weak Bases(pKa 8-10)

8M-S029-4GA

Neutral 8M-S100-4GA

Weak Acids (pKa 2-4)

8M-S123-4GA

Strong Acids (pKa <2)

8M-S038-4GA

π-π Bonding Hydrogen Bonding Dipole-Dipole Interactions

N..

n)

)

O

N..

n)

)

O

Hydrophobic Interaction

N..

n))

O

)

S – O-

O

O

=

= H+)

)

S – O-

O

O

=

= H+)

S – O-

O

O

=

= H+)

)

Strong Cation-Exchange

)

S – O-

O

O

=

= H+)

)

S – O-

O

O

=

= H+)

S – O-

O

O=

= H+)

)

π-π Bonding

)

S – O-

O

O

=

= H+)

)

S – O-

O

O

=

= H+)

S – O-

O

O

=

= H+)

)

Hydrophobic Interaction

Weak Cation-Exchange

OH

O

)

)

OH

)

)O

O

OH

)

)

π-π BondingOH

O

)

)

OH

)

)O

O

OH)

)

Hydrophobic Interaction

OH

O

)

)

OH

)

)O

O

OH

)

)

Strong Anion-Exchange π-π Bonding

N+

)

)CH3

CH3

N+

)

)CH3

CH3

N+

)

)CH3

CH3

N+

)

)CH3

CH3

N+

)

)CH3

CH3

N+

)

)CH3

CH3

Hydrophobic Interaction

N+

)

)CH3

CH3

N+

)

)CH3

CH3

N+

)

)CH3

CH3

Weak Anion-Exchange π-π Bonding

NH

)

) NH2

NH

)

) NH2

NH

)

) NH2

Hydrophobic Interaction

NH

)

) NH2

NH

)

) NH2

NH

)

) NH2NH

)

) NH2

NH

)

) NH2

NH

)

) NH2

Strata-X-CW 33 µm Polymeric Weak Cation-Exchange Microelution 96-Well Plate, 2 mg/well

Strata-X-C 33 µm Polymeric Strong Cation-Exchange Microelution 96-Well Plate, 2 mg/well

Strata-X 33 µm Polymeric Reversed Phase Microelution 96-Well Plate, 2 mg/well

Strata-X-A 33 µm Polymeric Strong Anion-Exchange Microelution 96-Well Plate, 2 mg/well

Strata-X-AW 33 µm Polymeric Weak Anion-Exchange Microelution 96-Well Plate, 2 mg/well

Strata-X Microelution Method Development 96-Well Plates

Phenomenex l WEB: www.phenomenex.com

If Strata-X Microelution 96-Well SPE Plates do not perform as well or better than your current Microelution 96-Well Plate SPE, return the product with comparative data within 45 days for a FULL REFUND.

Page 15: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

15

Cost Effective Benchtop Processing

96-Well Plate Vacuum Manifold

Presston™ 100 Positive Pressure Manifold

Collection Plates (deep well, polypropylene)Part Number Description Unit PriceAH0-7192 350 µL/well, Square 50/pkAH0-7193 1 mL/well, Square 50/pkAH0-7279 1 mL/well, Round/Round Bottom, 7 mm 50/pkAH0-7194 2 mL/well, Square 50/pkAH0-8635 2 mL/well, Square/Round-Conical Bottom 50/pkAH0-8636 2 mL/well, Round/Round Bottom, 8 mm 50/pk

Sealing Mats (silicone)Part Number Description Unit PriceAH0-8633 Pierceable, 96-Round Well 8 mm 50/pk

Description 100/pk Price 1000/pk PriceVial Kit, Snap, µVial i3 (Qsert), Clear w/ Patch + PTFE/Silicone AR0-9671-12 AR0-9671-13Vial Kit, Snap, µVial i3 (Qsert), Clear w/ Patch + PTFE/Silicone, preSlit AR0-9672-12 AR0-9672-13Vial Kit, 9 mm, µVial i3 (Qsert) Clear w/ Patch + PTFE/Silicone AR0-9973-12 AR0-9973-13Vial Kit, 9 mm, µVial i3 (Qsert) Clear w/ Patch + PTFE/Silicone, preSlit AR0-9974-12 AR0-9974-13Cert+ Vial Kit, 9 mm, µVial i3 (Qsert) Clear w/ Patch + PTFE/Silicone, preSlit cap*

AR0-9974-12-C AR0-9974-13-C

Type Finish Material Total Volume Residual Volume Available as12 x 32mm Specialty Vials

Snap to Vials, Specialty

Inserts for 9-425 Screw-Tops Vials

12 x 32mm Specialty Vials

Snap to Vials, Specialty

Inserts for 9-425 Screw-Tops Vials

Insert Vial

µVial i3 (Qsert)

11 mm Snap or9-425 Screw

ThreadGlass 475 µL < 2 µL

Convenience Kits (certified and regular)

* Bonded-In Septa

Verex™ Vials

Part No. DescriptionAH0-9334 Presston 100 Positive Pressure Manifold, 96-Well PlateAH0-9342 Presston 100 Positive Pressure Manifold, 3 mL Tube Complete Assembly

AH0-9347 Presston 100 Positive Pressure Manifold, 3 mL Tube Complete AssemblyAH0-9343 Presston 100 Positive Pressure Manifold, 6 mL Tube Complete Assembly

Part No. Description UnitAH0-8950 96-Well Plate Manifold, Universal w/vacuum gauge ea

**Manifold, compatible with 2 mL Impact plate, Strata and Strata-X 96-well plate formats.

Phenomenex l WEB: www.phenomenex.comPhenomenex l WEB: www.phenomenex.com

Page 16: Polymeric SPE Successful Bioanalytical Sample …...Part No. AH0-9334 Phenomenex l WEB: 9 Absolute Recovery of Goserelin at 5 ng/mL Strata-X-CW Microelution 96-Well SPE Plate, 2 mg/well

Suc

cess

ful B

ioan

alyt

ical

Sam

ple

Pre

par

atio

n

Wit

hout

the

Dry

Do

wn

• In

crea

se s

ensi

tivi

ty

• P

roce

ss s

mal

l or

limite

d s

amp

le v

olu

mes

• S

ave

tim

e an

d r

educ

e co

sts

• R

educ

e lo

ss o

f ch

alle

ngin

g a

naly

tes

Mic

roel

utio

n 96

-Wel

l SP

E P

late

s

www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at [email protected]

Australiat: +61 (0)2-9428-6444

[email protected]

Austriat: +43 (0)1-319-1301

[email protected]

Belgiumt: +32 (0)2 503 4015 (French)t: +32 (0)2 511 8666 (Dutch)

[email protected]

Canadat: +1 (800) 543-3681

[email protected]

Chinat: +86 400-606-8099

[email protected]

Denmarkt: +45 4824 8048

[email protected]

Finlandt: +358 (0)9 4789 0063

[email protected]

Francet: +33 (0)1 30 09 21 10

[email protected]

Germanyt: +49 (0)6021-58830-0

[email protected]

Indiat: +91 (0)40-3012 2400

[email protected]

Irelandt: +353 (0)1 247 5405

[email protected]

Italyt: +39 051 6327511

[email protected]

Luxembourgt: +31 (0)30-2418700

[email protected]

Mexicot: 01-800-844-5226

[email protected]

The Netherlandst: +31 (0)30-2418700

[email protected]

New Zealandt: +64 (0)9-4780951

[email protected]

Norwayt: +47 810 02 005

[email protected]

Portugalt: +351 221 450 488

[email protected]

Singaporet: +65 800-852-3944

[email protected]

Spaint: +34 91-413-8613

esp [email protected]

Swedent: +46 (0)8 611 6950

[email protected]

Switzerlandt: +41 61 692 20 20

[email protected]

United Kingdomt: +44 (0)1625-501367

[email protected]

USAt: +1 (310) 212-0555

[email protected]

All other countries Corporate Office USA

t: +1 (310) 212-0555 [email protected]

BR

3052

0618

_W

Terms and Conditions

Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions

Trademarks Kinetex and Strata are registered trademarks of Phenomenex. Aeris, Presston and Verex are trademarks of Phenomenex. Triple Quad and API 5000 are trademarks of AB SCIEX Pte. Ltd. AB SCIEX is being used under license.

Strata-X is patented by Phenomenex. U.S. Patent No. 7,119,145

FOR RESEARCH USE ONLY. Not for use in clinical diagnostic procedures. © 2018 Phenomenex, Inc. All rights reserved.