Upload
phungdien
View
219
Download
0
Embed Size (px)
Citation preview
POD’S in Data Centres
Presented by: Greg GoodePresented by: Greg Goode
The Frame Group Pty Ltd
POD
SOLUTIONS
REFERRED TO AS:
POD’S in Data Centres
?DATA Centres
REFERRED TO AS:
Cells
Modular Rooms
High Density Zones
Portable Modular Data
Centres (Containers)
?
POD’S in Data Centres
�Multiple Interpretations
�Varied Environments�Varied Environments
�Multiple Definitions
POD’S in Data Centres
I call this the “Raw Google Statistic”
No shortage of comment, advise, information
POD’S in Data Centres
TOPIC AGENDA
•Taxonomy
•Characteristics•Characteristics
•History
•Commercials
•Green
•Benefits
•Future
POD’S in Data Centres
TAXONOMYTAXONOMY
POD’S in Data Centres
POD’S in Data Centres
COMPARTMENTALISED OPEN DATA HALL ENVIRONMENT
POD’S in Data Centres
ENGINEERED AISLE CONTAINED-RACK ARRANGEMENT
POD’S in Data Centres
MODULAR PRE-FABRICATED ROOM
POD’S in Data Centres
UNIVERAL FORM FACTOR SHIPPING CONTAINER
POD’S in Data Centres
CHARACTERISTICS�ENVIRONMENTS�TECHNOLOGIES
POD’S in Data Centres
COMPARTMENTALISED DATA HALL ENVIRONMENT
� ONE AREA SEGREGATED INTO SMALLER HALLS
Total 1000m²
Compartmented in 5 x 200m² AREAS
� SPECIFIC MAXIMUM ENERGY LOAD PER HALL SCALABLE e.g.
240kW, 480kw, 640kw etc240kW, 480kw, 640kw etc
� REPLICATABLE ENVIRONMENT – DESIGN | BUILD
IT HAS A CONSTRAINED SPACE AND ENERGY ENVELOPE
POD’S in Data Centres
AISLE CONTAINED MULTI-RACK ENCLOSURE
� SINGLE AISLE – TWO SYMMETRICAL ROWS OF RACKS WITH
AISLE CONTAINMENT (HOT/COLD)
� SPECIFIC MAXIMUM ENERGY LOAD PER ENCLOSURE
SCALABLE e.g. 240kW, 480kw, 640kw etc
� REPLICATABLE ENVIRONMENT – DESIGN | BUILD
IT HAS A CONSTRAINED SPACE AND ENERGY ENVELOPE
POD’S in Data Centres
UNIVERAL FORM FACTOR SHIPPING CONTAINER
� 20’ OR 40’ ISO9000 CONTAINER (PURPOSE BUILT)
� SPECIFIC MAXIMUM ENERGY LOAD PER ENCLOSURE
SCALABLE e.g. 240kW, 480kw, 640kw etc
� REPLICATABLE ENVIRONMENT – DESIGN | BUILD� REPLICATABLE ENVIRONMENT – DESIGN | BUILD
IT HAS A CONSTRAINED SPACE AND ENERGY ENVELOPE
POD’S in Data Centres
POD
CONTAINMENT RACKING COOLING POWERDATA CABLING
MANAGEMENTFIRE
MONITORING &
MANAGEMENTSECURITY
MODULAR | SCALEABLE | ENERGY EFFICIENT
POD’S in Data Centres
POD MORPHOLOGY - CONTAINMENT
• BUILDING
• CLOSED CONTAINED RACKS
• UNIVERSAL FORM FACTOR CONTAINER
� COMMON CHARACTERISTICS
� MODULAR | COMPARTMENTALISED
� SCALABLE
� ENERGY EFFICIENCY
� REPLICABLE
POD’S in Data Centres
POD MORPHOLOGY - RACKING
• COMMON “INTELLIGENT” RACKS
Allowing for management of :
� server mounting
� power distribution | management
� cooling distribution | management
� cabling distribution | management� cabling distribution | management
� fire control
� security
• IDENTICAL PHYSICALITY
� Dimensions
� Access-ability
� Engineering specification
POD’S in Data Centres
POD MORPHOLOGY - COOLING
Multiple solutions:
� In-row cooling
� Air-side economiser
� Perimeter cooling
� Engineered with:
� Access floor plenum/or not
� Overhead plenum | chimney
� Hot /Cold aisle containment
� Chilled water | refrigerant | air-side
POD’S in Data Centres
POD MORPHOLOGY - POWER
Multiple power distribution solutions:
� In-row UPS | battery | PDU
� Centralised UPS | Battery | PDU
� Engineered with:
� Overhead pathway
� Under floor pathway
� Multiple paths
POD’S in Data Centres
POD MORPHOLOGY - DATA CABLING
Multiple cable distribution solutions:
� Copper
� Fibre� Fibre
� Modular or pair managed
� Engineered with:
� Overhead pathway
� Under floor path way
� Wireless
POD’S in Data Centres
POD MORPHOLOGY - FIRE
Multiple solutions:
� Gas
� Water (Pre-action | Mist)
� Engineered with:
� Detection (Vesda | point)
POD’S in Data Centres
POD MORPHOLOGY - MONITORING & MANAGEMENT
Solutions:� MONITORING & ALARMING
� Cooling� Power� Security� Security� Fire
� MANAGEMENT� Data collection |storage | mining� Analysis� Reporting� Pre-emptive action� Planning | capacity� Remote management� Asset | RFID
POD’S in Data Centres
POD MORPHOLOGY - SECURITY
Multiple solutions:
� Prox
� Bio-metric
� Key� Key
� RFID
� Engineered with:
� CCTV
� Motion sensing
POD’S in Data Centres
COMPARTMENTALISED DATA HALL ENVIRONMENT
POD’S in Data Centres
ENGINEERED AISLE CONTAINED-RACK ARRANGEMENT
POD’S in Data Centres
UNIVERAL FORM FACTOR SHIPPING CONTAINER
POD’S in Data Centres
HISTORY
�DRIVERS
POD’S in Data Centres
HISTORICAL TIMELINE
�WITHIN THE LAST 2 - 3 YEARS
SIGNIFICANT DRIVERS
�ITS ALL ABOUT ENERGY DENISITY | ENERGY EFFICIENCY
OTHER DRIVERSOTHER DRIVERS
�MODULAR | SCALABLE (‘IT ‘ MANTRA FOR A GOOD DECADE)
�BUILDING ARCHITECTURE | WAREHOUSE | INFRASTRUCTURE MINIMALISM
�REPLICATABLE DEPLOYMENT
�TIME TO PROVISION
POD’S in Data Centres
ROIC
OM
ME
RC
IAL
S
TCO
CO
MM
ER
CIA
LS
POD’S in Data Centres
�ONE DESIGN – OFF THE SHELF BUT SCALABLE
�COMMON COMPONENTS
CONTAINMENT, RACKING, POWER, COOLING, CABLING, FIRE,
MANAGEMENT, SECURITY
�JUST in TIME - SITE PROVISIONING
�QUALITY CONTROL TIGHTER – FIELD V FACTORY
SITE CO-ORD, REWORK,WARRANTY, DEFECTS
POD’S in Data Centres
�SINGLE SUPPLIER – THOUGH MULTIPLE VENDORS
�SINGLE SUPPORT CONTRACT
�ENERGY EFFICIENCY GAINS (QUOTING 40% IMPROVEMENT)
�REDUCED REAL-ESTATE FOOTPRINT
�DENSIFICATION OF PROCESSING POWER / M²
POD’S in Data Centres
�TCO (15 YEAR PERIOD)
�OPEN ARCHITECTURE v POD = PROJECTED 30 – 55% REDUCTION
�REDUCED:
�PLANNING
�STARTUP CAPITAL COST�STARTUP CAPITAL COST
�REAL –ESTATE
�PROVISIONING TIME
�OPERATIONAL ENERGY COSTS (GREATEST REDUCTION)
�OPERATIONAL MANAGEMENT (COMMON ENVIRONMENT)
POD’S in Data Centres
OPERATIONS
POD’S in Data Centres
�ONE SUPPLIER
�ONE POINT OF CONTACT | MULTIPLE VENDORS
�ONE SERVICE CONRACT
�SUPPORT
�UPGRADE
�MONITORING & MANAGEMENT
�REAL-TIME
�PRO-ACTIVE
�PREDICATIVE
�CHANGE MANAGEMENT
�DEFINED ENVIRONMENT
POD’S in Data Centres
�CONFIGURATION MANAGEMENT
�MAPPED TO POD
�IT & FACILITY MANAGEMENT
�CONVERGENCE OF BACKEND - FRONTEND ENGINEERING
�CONVERGENCE OF ‘IT & FACILITY’ PERSONNEL
�CONVERGENCE OF COST Centres (GREATER VISIBILITY)
�IMPROVED RESPONSIVENESS TO
‘IT’ ARCHITECTURAL CHANGE | CAPACITY PLANNING | PROVISIONING
POD’S in Data Centres
GREEN
POD’S in Data Centres
�PREDICTABLE PERFORMANCE
�NO 2ND GUESSING IN DESIGN
�PUE, DCiE, WPSM, CADE
�DEFINABLE | MEASURABLE | TUNABLE
�ADAPTABLE TO EFFICIENT ENERGY SOLUTIONS
�‘IT’ ARCHITECTURE�‘IT’ ARCHITECTURE
�COOLING
�POWER
�ADAPTABLE TO ‘GREENER’ AND SMARTER BUILDING DESIGN
�ENABLES ‘LEEDS’ AND EQUIVALENT RATINGS
�MODULAR | SCALABLE | DYNAMIC
POD’S in Data Centres
�IN BUILT ENGINEERED ENERGY EFFICIENCY PRINCIPLES
�RACKING
�COOLING
�POWER
�MANAGEMENT & MONITORING
�CONSTRAINED ENVIRONMENT | GREATER CONTROL�CONSTRAINED ENVIRONMENT | GREATER CONTROL
�SCALABLE DURING LIFE CYCLE
�MEETS IMMEDIATE PROCESSING NEEDS
�NO WASTED ENERGY UP FRONT
POD’S in Data Centres
BENEFITS
POD’S in Data Centres
�STRATEGIC PERSPECTIVE
�BUSINESS CORE COMPETENCY
�MARKET DIFFERENTIATOR
�COMPETITION
�INITIATIVES | MARKETING |SALES |PRODUCTION etc
�FINANCE | PLANs 5 – 10 – 20 yr
TRANSLATES TO
�TACTICAL
�PROPERTY
�TECHNOLOGY
�OPERATIONAL
POD’S in Data Centres
�PODS ADDRESS
�PROPERTY
�GREATER BUILDING SITE SCOPE
�SMARTER BUILDING CONSTRUCTION
�JUST IN TIME | LOWER PROVISIONIONG COST
�ENERGY EFFICIENT
�TECHNOLOGY
�SMART RACKS – POWER | COOLING | CABLING | FIRE
�COOLING SOLUTIONS – ADAPTABLE SOLUTIONS
�POWER SOLUTIONS – ADAPATBALE SOLUTIONS
�ENERGY DENSITIES – HIGHER | DEFINABLE | SCALABLE
�MANAGEMENT – ENERGY (POWER, COOLING)
POD’S in Data Centres
�OPERATIONS
�COMMON ENVIRONMENT
�REDUCED IMPLEMENTATION TO OPERATIONAL
�REDUCED MANPOWER
�MONITORING & MANAGEMENT
�SERVICE CONTRACT�SERVICE CONTRACT
�ONE STOP
�CONTEMPORARY TECHNOLOGY
�MINIMAL NEW LEARNINGS
�REDUCED ‘TCO’
POD’S in Data Centres
FUTURE
POD’S in Data Centres
�THE DATA CENTRE PARADIGM TRENDS
�ENERGY EFFICIENCY
�PRINCIPLES OF MODULAR | SCALABLE
(TOUCHES EVERYTHING IN THE DATA CENTRE)
�HIGHER DENSITY COMPUTING | CLOUD
(PROCESSING POWER)
�STORAGE GROWTH
�JUST IN TIME (BUSINESS NEEDS)
POD’S in Data Centres
�THE DATA CENTRE PARADIGM TRENDS
�BUILDING ARHITECTURE EVOLVING | SUSTAINABILITY
�RETRO-FITS (THE LEGACY)
�REDUCED ‘TCO ‘
�SHORTER ‘ROI’ PERIOD
�COMMODITISATION
POD’S in Data Centres
THANK YOU
47
THANK YOU