78 | advance/Laboratory • April 2006 www.advanceweb.com
POCTCompany Info Product Name Type of
AnalyzerSize and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
Abbott Point of Care
104 Windsor Center DriveEast Windsor, NJ 08520
Contact: i-STAT 1Michael A. Saperstein (609) 443-9300
E-mail: [email protected];[email protected]
Web Site: www.abbottpointofcare.com
i-STAT 1 Portable Clini-cal Analyzer
W x D x L = 2.5 in x 2.0 in x 8.2 in; Weight – 18 oz
Handheld Emergency de-partments, respi-ratory therapy, transports, mil-itary (field); any place bedside blood analysis is required
Variety of blood gas-es, electrolytes, chemistries, co-agulation, cardi-ac markers
Whole blood Standard lab methodologies (impedance, elec-trogenic)
Yes Internal, auto-matic electron-ic QC
Input for user and patient ID numbers; user programmable
Approx. 2 drops (var-ies by test cartridge)
Blood Gas/Chem/Electrolyte: am-perometric; Coagu-lation: electrogenic; Immunoassay: ELI-SA/amperometric
Approx. 2 minutes (var-ies by car-tridge)
Yes Yes Yes, most com-mercial data management packages
Infrared Yes Yes Yes Yes Portable 1.0 lb analyz-er can perform electro-lytes, chemistry, blood gas, coagulation and cardiac markers on single platform
Contact: Precision PCxKen Stoner(609) 469-0322fax: (609) 443-9310
Web Site:www.abbottpointofcare.com
Precision PCx Glucose Meter 7.7” x 2.9” x 2”, 10 oz./ $995
Handheld; glucose only; test strip
Hospital-wide Glucose Whole blood/drop, can apply blood directly to test strip
YSI Accuracy: cap-illary blood y=0.91x + 0.91, r=0.98/YSI. Precision: Blood samples: CV 2.9% to 5.1%
User-defined QC lockout; stores 4,000 patient results and 1,000 QC with full date and time; oper-ator ID and pa-tient ID; data review
QC lockout for user ID fail-ure, QC failure, download time if selected
3.5 micro-liters with PCx/2.5 mi-croliters with PCx Plus
Amperomet-ric: Glucose oxi-dase with Precision PCx strips. Glu-cose dehydroge-nase with PCx Plus test strips
20 seconds Hands-free data download-ing via docking station
Yes TCP/TP, RS-232, bi-directional
Future de-velopment
Yes Yes Yes User defined remote con-trol of instru-ment and reagents; QC lockout for user ID fail-ure; QC fail-ure; download time if se-lected
Patented fill-trigger electrode designed to start test only when sufficient sample is detected; ability to re-apply blood within 30 seconds; positive re-agent ID, positive cal-ibration ID-no need to visually verify code key against test strip vial; state-of-the-art inter-facing to HIS and LIS systems via QC Man-ager; sybase interfac-ing engine
Bayer HealthCare Diagnostics Division
Contact: Susan Oelerking(914) 631-8000
E-mail:[email protected]
Web Site:www.bayerdiag.com
Clinitek Status Analyzer
Urinalysis analyzer for POC/POL
D x W x H = 10.7 in x 6.7 in x 6.2 in; 3.65 lbs.
LED optics, 6 wavelengths
Urinalysis screening, hCG screening in POC/POL
Range of Bay-er’s most pop-ular urinalysis reagent strips including Mul-tistix® 10SG, Multistix® 8SG, Multistix PRO®, Clinitek® Mi-croalbumin and Clinitest® hCG Test. Addition-al tests and im-munoassays to come.
Urine Reference meth-od depends on analyte being tested
Error tolerances depend on ana-lyte being mea-sured
Numerous user-interface prompts
Password pro-tected instru-ment settings
1 minute RS232 inter-face for data download to POC interface
Yes PC, Point-of-Care LIS
No Simple to use; user in-terface with touch screen operation; pa-tient information and operator identification input; broad menu; 200 test memory is downloadable for im-proved data manage-ment; battery and/or main operation
DCA 2000®+ Analyzer with DCA 2000 He-moglobin A1c reagent kit
Immuno-chemistry Ana-lyzer/Diabetes Analyzer
Immuno-chemistry an-alyzer
Diabetes man-agement
Quantitative measurement of Hemoglo-bin A1c
Blood HPLC Standard con-trol solutions available
Numerous in-ternal perfor-mance checks
1 uL Inhibition of la-tex agglutination assay
6 minutes RS 232 Inter-face
LIS, PC RS 232 No No No No NGSP Certified, IFCC Certified
DCA 2000®+ Analyzer with Microalbumin/Creatinine Re-agent Kit
Immuno-chemistry an-alyzer
Immuno-chemistry an-alyzer
Diabetes man-agement
Quantitative de-termination of Microalbumin:Creatinine ratio
Urine Immunoassay/JAFFE reaction
Standard con-trols
System perfor-mance checks
40 uL Antibody binds with albumin Benedict/Dehre Chemistry for cre-atinine
7 minutes RS 232 Inter-face
LIS, PC RS 232 No No No No No NGSP Certified, IFCC Certified
Rapidpoint 400/405 blood gas analyzer
Blood gas W x D x H = 11.5 in x 16 in x 21.5 in; 31 lbs.
Integrated, multi-use cartridge sys-tem
ICU, ER, OR, RT Measured (range) pH; pCO2, mm Hg; pO2, mm Hg; BP, mm Hg; Hct, %; K+, mmol/L; NA+, mmol/L; Ca++, mmol/L; CL-, mmol/L; Others (Cl-, Glucose, tHb, CO-ox Derived: a/A; A-aDO2; BE; BEecf; Hb; HCO3; ctOs; SB; SO2; ctCO2 Oth-ers: A-a/a DO2; RI; BO2
Heparinized whole blood
Analyte reference method
Ampouled QC or automatic QC module; QC lockout; remote QC triggering
Three levels for 500 users
100–200 uL Direct potentiom-etry ( pH, pCO2, NA+, CA++, CL-, K+) amperome-try (pO2, glucose) corrected conduc-timetry (Hct) mut-li-wavelengths spectrophotome-try on whole blood (tHB, O2Hb, COHb, MetHb, HHb)
60 seconds Ability to down-load patient data; calibra-tion and QC in-formation
RS 232, TCP-IP
Optional No Yes First blood gas system specifically designed for POC with integrated CO-oximetry for com-prehensive and ac-curate oxygen status; intuitive user interface with onboard train-ing video, high-level of bio safety; six types of measuring cartridges
BUYERS GUIDE
6Th AnnUAl
The 6th annual “ADVANCE Point-of-Care Testing Buyers Guide” represents a collaborative effort between laboratory administrators, POCT manufacturers and ADVANCE editorial staff.
Here, respondents surveyed offer POCT-related products for hospital and non-hospital laboratories.
Designed for ease of use, this chart includes contact names, telephone/fax numbers, e-mail/Web site address-es, product and cost, type of analyzer, size and weight of device, type of design and other POCT product-specific
EDITOR’S nOTE:
6Th
An
nU
Al
PO
CT
BU
YER
S G
UID
E
www.advanceweb.com advance/Laboratory • April 2006 | 79
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
Abbott Point of Care
104 Windsor Center DriveEast Windsor, NJ 08520
Contact: i-STAT 1Michael A. Saperstein (609) 443-9300
E-mail: [email protected];[email protected]
Web Site: www.abbottpointofcare.com
i-STAT 1 Portable Clini-cal Analyzer
W x D x L = 2.5 in x 2.0 in x 8.2 in; Weight – 18 oz
Handheld Emergency de-partments, respi-ratory therapy, transports, mil-itary (field); any place bedside blood analysis is required
Variety of blood gas-es, electrolytes, chemistries, co-agulation, cardi-ac markers
Whole blood Standard lab methodologies (impedance, elec-trogenic)
Yes Internal, auto-matic electron-ic QC
Input for user and patient ID numbers; user programmable
Approx. 2 drops (var-ies by test cartridge)
Blood Gas/Chem/Electrolyte: am-perometric; Coagu-lation: electrogenic; Immunoassay: ELI-SA/amperometric
Approx. 2 minutes (var-ies by car-tridge)
Yes Yes Yes, most com-mercial data management packages
Infrared Yes Yes Yes Yes Portable 1.0 lb analyz-er can perform electro-lytes, chemistry, blood gas, coagulation and cardiac markers on single platform
Contact: Precision PCxKen Stoner(609) 469-0322fax: (609) 443-9310
Web Site:www.abbottpointofcare.com
Precision PCx Glucose Meter 7.7” x 2.9” x 2”, 10 oz./ $995
Handheld; glucose only; test strip
Hospital-wide Glucose Whole blood/drop, can apply blood directly to test strip
YSI Accuracy: cap-illary blood y=0.91x + 0.91, r=0.98/YSI. Precision: Blood samples: CV 2.9% to 5.1%
User-defined QC lockout; stores 4,000 patient results and 1,000 QC with full date and time; oper-ator ID and pa-tient ID; data review
QC lockout for user ID fail-ure, QC failure, download time if selected
3.5 micro-liters with PCx/2.5 mi-croliters with PCx Plus
Amperomet-ric: Glucose oxi-dase with Precision PCx strips. Glu-cose dehydroge-nase with PCx Plus test strips
20 seconds Hands-free data download-ing via docking station
Yes TCP/TP, RS-232, bi-directional
Future de-velopment
Yes Yes Yes User defined remote con-trol of instru-ment and reagents; QC lockout for user ID fail-ure; QC fail-ure; download time if se-lected
Patented fill-trigger electrode designed to start test only when sufficient sample is detected; ability to re-apply blood within 30 seconds; positive re-agent ID, positive cal-ibration ID-no need to visually verify code key against test strip vial; state-of-the-art inter-facing to HIS and LIS systems via QC Man-ager; sybase interfac-ing engine
Bayer HealthCare Diagnostics Division
Contact: Susan Oelerking(914) 631-8000
E-mail:[email protected]
Web Site:www.bayerdiag.com
Clinitek Status Analyzer
Urinalysis analyzer for POC/POL
D x W x H = 10.7 in x 6.7 in x 6.2 in; 3.65 lbs.
LED optics, 6 wavelengths
Urinalysis screening, hCG screening in POC/POL
Range of Bay-er’s most pop-ular urinalysis reagent strips including Mul-tistix® 10SG, Multistix® 8SG, Multistix PRO®, Clinitek® Mi-croalbumin and Clinitest® hCG Test. Addition-al tests and im-munoassays to come.
Urine Reference meth-od depends on analyte being tested
Error tolerances depend on ana-lyte being mea-sured
Numerous user-interface prompts
Password pro-tected instru-ment settings
1 minute RS232 inter-face for data download to POC interface
Yes PC, Point-of-Care LIS
No Simple to use; user in-terface with touch screen operation; pa-tient information and operator identification input; broad menu; 200 test memory is downloadable for im-proved data manage-ment; battery and/or main operation
DCA 2000®+ Analyzer with DCA 2000 He-moglobin A1c reagent kit
Immuno-chemistry Ana-lyzer/Diabetes Analyzer
Immuno-chemistry an-alyzer
Diabetes man-agement
Quantitative measurement of Hemoglo-bin A1c
Blood HPLC Standard con-trol solutions available
Numerous in-ternal perfor-mance checks
1 uL Inhibition of la-tex agglutination assay
6 minutes RS 232 Inter-face
LIS, PC RS 232 No No No No NGSP Certified, IFCC Certified
DCA 2000®+ Analyzer with Microalbumin/Creatinine Re-agent Kit
Immuno-chemistry an-alyzer
Immuno-chemistry an-alyzer
Diabetes man-agement
Quantitative de-termination of Microalbumin:Creatinine ratio
Urine Immunoassay/JAFFE reaction
Standard con-trols
System perfor-mance checks
40 uL Antibody binds with albumin Benedict/Dehre Chemistry for cre-atinine
7 minutes RS 232 Inter-face
LIS, PC RS 232 No No No No No NGSP Certified, IFCC Certified
Rapidpoint 400/405 blood gas analyzer
Blood gas W x D x H = 11.5 in x 16 in x 21.5 in; 31 lbs.
Integrated, multi-use cartridge sys-tem
ICU, ER, OR, RT Measured (range) pH; pCO2, mm Hg; pO2, mm Hg; BP, mm Hg; Hct, %; K+, mmol/L; NA+, mmol/L; Ca++, mmol/L; CL-, mmol/L; Others (Cl-, Glucose, tHb, CO-ox Derived: a/A; A-aDO2; BE; BEecf; Hb; HCO3; ctOs; SB; SO2; ctCO2 Oth-ers: A-a/a DO2; RI; BO2
Heparinized whole blood
Analyte reference method
Ampouled QC or automatic QC module; QC lockout; remote QC triggering
Three levels for 500 users
100–200 uL Direct potentiom-etry ( pH, pCO2, NA+, CA++, CL-, K+) amperome-try (pO2, glucose) corrected conduc-timetry (Hct) mut-li-wavelengths spectrophotome-try on whole blood (tHB, O2Hb, COHb, MetHb, HHb)
60 seconds Ability to down-load patient data; calibra-tion and QC in-formation
RS 232, TCP-IP
Optional No Yes First blood gas system specifically designed for POC with integrated CO-oximetry for com-prehensive and ac-curate oxygen status; intuitive user interface with onboard train-ing video, high-level of bio safety; six types of measuring cartridges
6th annual poct buyers guide
information. The Distinguishing Features category identifies a product’s top features.
ADVANCE relies on its readership to improve the quality of special sections. If you find this buyers guide useful or if you have suggestions to increase its effectiveness, please contact us or forward a letter to:
Lynn Nace, Editor, ADVANCE for Administrators of the Laboratory, 2900 Horizon Drive, King of Prussia, PA 19406, or e-mail [email protected].
Listings do not represent endorsement by ADVANCE.
6th a
nn
ua
l po
ct b
uyer
s g
uid
e
80 | advance/Laboratory • April 2006 www.advanceweb.com
Bio-Rad Laboratories
Contact:
Customer Service (800) 854-6737
Web Site:www.bio-rad.com
Quality con-trol products, including Me-ter Trax Con-trol, a whole blood control for glucose, he-moglobin and hematocrit test-ing; urine tox-icology and other controls are available
Glucose: Accu-Chek ADVAN-TAGE, Asencia Elite, MediS-ense Precision Xtra, Fast Take, Glucometer ENCORE QA, One Touch II, Profile, Pre-cision Q-I-D, Precision G, Precision Pcx, Sure Step. Hemoglobin: Hemocue, Re-flotron, SPUN-CRIT, Manual Methods. He-matocrit: He-mataStat, IEC (PCV), i-STAT, READACRIT, SPUNCRIT, Statspin III, IV & V, StatSpin MP, CritSpin. Urine Toxicol-ogy: TOX/SEE, Biosite Triage and other POC methods
Dade Behring Inc.
Contact: Leslie Dakarian(847) 236-7286
E-mail: [email protected]
Web Site:www.dadebehring.com
Stratus® CS Acute Care™ Diagnostic Sys-tem
Stat and near patient test-ing for cardiac assays, BhCG and D-dimer
18 in x 27 in x 22 in; 140 lbs
Acute Care™ Kiosk that consists of an instrument, transportable cart, refriger-ator and un-interruptible power sup-ply; may also be used as a benchtop in-strument
ED, stat labs, coronary care units, urgent care centers, main labs
Troponin-I, NT-proBNP myo-globin, mass CKMB, D-di-mer, and BhCG. CardioPhase® hsCRP in devel-opment
Heparinized whole blood and plasma
Internal reference preparations for cardiac assays and D-dimer; 3rd IS for BhCG
Microproces-sor continuously monitors all op-erating systems to ensure per-formance within specifications
System check: Electronic QC to meet daily QC requirements
System check lock-out: Re-quires Sys-tem Check to be performed within lab de-fined period of time
Liquid QC Lock-out: Requires liquid QC to be performed within lab de-fined period of time
Liquid QC Range Lock-out: Prevents patient testing when QC is out of lab defined QC range
Critical Config-urations: Lab password pro-tection
Operator Val-idation: Valid operator ID re-quired
Minimum 3 ml whole blood; 200 uL of plas-ma
Solid phase two-site sandwich fluorometric im-munoassay uti-lizing single use TestPaks to help eliminate contami-nation and reagent waste
Approximate-ly 14 minutes to first result; 4 minutes for each addi-tional
LIS compatible (RS-232) with uni-directional download
Instrument can inter-face direct-ly to the LIS or to POC connectivity middleware (see con-nectivity op-tions)
POC Connectiv-ity Middleware Options: Tel-cor Quick-Linc® and QML®; Med-ical Automation Systems RALS-Plus®
No The SCS is compliant with POCT 1A when interfaced with Tel-cor Quick-Linc® and QML®; Medical Automation Systems RALS-Plus®
N/A Automatic lockout based on QC perfor-mance, oper-ator validation and instru-ment status
The Stratus CS Analyz-er, designed for acute-care diagnostics, is a model of cost-effec-tiveness for both your laboratory and near-patient setting; it’s a random-access ana-lyzer, delivering quanti-tative cardiac markers, BhCG, D-Dimer results from a whole blood sample in as little as 14 minutes; the simple three-step process—load sample and ro-tor, load testpack(s) and press Start— is easy to use by all skill levels
HemoCue Inc.Contact:
(800) 881-1611E-mail:
[email protected] Web Site:
www.hemocue.com
Hb 201+ An-alyzer
Hemoglo-bin testing for point of care
3.35 in x 6.3 in x 1.69 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Physician office, hospital, blood bank, dialysis center and pub-lic health
Single analyte Whole blood International Ref-erence Method (ICSH)
Automatic self-test
10 µl Absorbance pho-tometry; Azidemet-hemoglobin
<1 minute Lab quality results at the point of care; mea-sure at two wave-lengths to correct for turbidity; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Glucose 201 Analyzer
Glucose test-ing
3.35 in x 6.3 in x 1.69 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Physician office and hospital
Single analyte Whole blood Wet chemical glucose dehydro-genase
Automatic self-test
5 µl Absorbance pho-tometry; glucose dehydrogenase
40–240 sec-onds
Lab quality results at the point of care; cleared for screening, diagnosing and mon-itoring of diabetes; off meter dosage; mini-mum of interferences; no lot-to-lot varia-tion; no recalibration needed
Hb 201 DM An-alyzer
Hemoglobin testing with data manage-ment features
3.66 in x 6.7 in x 1.97 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Hospital Single analyte Whole blood International Ref-erence Method (ICSH)
QC lockout; op-erator ID; con-trol lot number; reagent lot number; date/time; result; range; pass/fail; comment code
Certified oper-ator ID and pa-tient ID entry, settings and memory erase functions may be password protected
10 µl Absorbance pho-tometry; Azidemet-hemoglobin
<1 minute Ethernet or USB to PC or laptop for full bi-direction-al communica-tion providing downloading and configura-tion features
Fully net-workable “out of the box”; may be inter-faced to LIS/HIS using third party software
LIS connectivity through third par-ty vendor
No Yes Yes No Yes; can be superviso-ry locked out using the He-moCue 201 DM PC Soft-ware
Lab quality results at the point of care; measure at two wave-lengths to correct for turbidity; full data, op-erator and analyzer management funtion-ality; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th
an
nu
al
po
ct
bu
yer
s g
uid
e
www.advanceweb.com advance/Laboratory • April 2006 | 81
Bio-Rad Laboratories
Contact:
Customer Service (800) 854-6737
Web Site:www.bio-rad.com
Quality con-trol products, including Me-ter Trax Con-trol, a whole blood control for glucose, he-moglobin and hematocrit test-ing; urine tox-icology and other controls are available
Glucose: Accu-Chek ADVAN-TAGE, Asencia Elite, MediS-ense Precision Xtra, Fast Take, Glucometer ENCORE QA, One Touch II, Profile, Pre-cision Q-I-D, Precision G, Precision Pcx, Sure Step. Hemoglobin: Hemocue, Re-flotron, SPUN-CRIT, Manual Methods. He-matocrit: He-mataStat, IEC (PCV), i-STAT, READACRIT, SPUNCRIT, Statspin III, IV & V, StatSpin MP, CritSpin. Urine Toxicol-ogy: TOX/SEE, Biosite Triage and other POC methods
Dade Behring Inc.
Contact: Leslie Dakarian(847) 236-7286
E-mail: [email protected]
Web Site:www.dadebehring.com
Stratus® CS Acute Care™ Diagnostic Sys-tem
Stat and near patient test-ing for cardiac assays, BhCG and D-dimer
18 in x 27 in x 22 in; 140 lbs
Acute Care™ Kiosk that consists of an instrument, transportable cart, refriger-ator and un-interruptible power sup-ply; may also be used as a benchtop in-strument
ED, stat labs, coronary care units, urgent care centers, main labs
Troponin-I, NT-proBNP myo-globin, mass CKMB, D-di-mer, and BhCG. CardioPhase® hsCRP in devel-opment
Heparinized whole blood and plasma
Internal reference preparations for cardiac assays and D-dimer; 3rd IS for BhCG
Microproces-sor continuously monitors all op-erating systems to ensure per-formance within specifications
System check: Electronic QC to meet daily QC requirements
System check lock-out: Re-quires Sys-tem Check to be performed within lab de-fined period of time
Liquid QC Lock-out: Requires liquid QC to be performed within lab de-fined period of time
Liquid QC Range Lock-out: Prevents patient testing when QC is out of lab defined QC range
Critical Config-urations: Lab password pro-tection
Operator Val-idation: Valid operator ID re-quired
Minimum 3 ml whole blood; 200 uL of plas-ma
Solid phase two-site sandwich fluorometric im-munoassay uti-lizing single use TestPaks to help eliminate contami-nation and reagent waste
Approximate-ly 14 minutes to first result; 4 minutes for each addi-tional
LIS compatible (RS-232) with uni-directional download
Instrument can inter-face direct-ly to the LIS or to POC connectivity middleware (see con-nectivity op-tions)
POC Connectiv-ity Middleware Options: Tel-cor Quick-Linc® and QML®; Med-ical Automation Systems RALS-Plus®
No The SCS is compliant with POCT 1A when interfaced with Tel-cor Quick-Linc® and QML®; Medical Automation Systems RALS-Plus®
N/A Automatic lockout based on QC perfor-mance, oper-ator validation and instru-ment status
The Stratus CS Analyz-er, designed for acute-care diagnostics, is a model of cost-effec-tiveness for both your laboratory and near-patient setting; it’s a random-access ana-lyzer, delivering quanti-tative cardiac markers, BhCG, D-Dimer results from a whole blood sample in as little as 14 minutes; the simple three-step process—load sample and ro-tor, load testpack(s) and press Start— is easy to use by all skill levels
HemoCue Inc.Contact:
(800) 881-1611E-mail:
[email protected] Web Site:
www.hemocue.com
Hb 201+ An-alyzer
Hemoglo-bin testing for point of care
3.35 in x 6.3 in x 1.69 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Physician office, hospital, blood bank, dialysis center and pub-lic health
Single analyte Whole blood International Ref-erence Method (ICSH)
Automatic self-test
10 µl Absorbance pho-tometry; Azidemet-hemoglobin
<1 minute Lab quality results at the point of care; mea-sure at two wave-lengths to correct for turbidity; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Glucose 201 Analyzer
Glucose test-ing
3.35 in x 6.3 in x 1.69 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Physician office and hospital
Single analyte Whole blood Wet chemical glucose dehydro-genase
Automatic self-test
5 µl Absorbance pho-tometry; glucose dehydrogenase
40–240 sec-onds
Lab quality results at the point of care; cleared for screening, diagnosing and mon-itoring of diabetes; off meter dosage; mini-mum of interferences; no lot-to-lot varia-tion; no recalibration needed
Hb 201 DM An-alyzer
Hemoglobin testing with data manage-ment features
3.66 in x 6.7 in x 1.97 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Hospital Single analyte Whole blood International Ref-erence Method (ICSH)
QC lockout; op-erator ID; con-trol lot number; reagent lot number; date/time; result; range; pass/fail; comment code
Certified oper-ator ID and pa-tient ID entry, settings and memory erase functions may be password protected
10 µl Absorbance pho-tometry; Azidemet-hemoglobin
<1 minute Ethernet or USB to PC or laptop for full bi-direction-al communica-tion providing downloading and configura-tion features
Fully net-workable “out of the box”; may be inter-faced to LIS/HIS using third party software
LIS connectivity through third par-ty vendor
No Yes Yes No Yes; can be superviso-ry locked out using the He-moCue 201 DM PC Soft-ware
Lab quality results at the point of care; measure at two wave-lengths to correct for turbidity; full data, op-erator and analyzer management funtion-ality; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th a
nn
ua
l po
ct b
uyer
s g
uid
e6th annual poct buyers guide
82 | advance/Laboratory • April 2006 www.advanceweb.com
HemoCue Inc.(continued)
Glucose 201 DM Analyzer
Glucose test-ing with data management features
3.66 in x 6.7 in x 1.97 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Hospital Single analyte Whole blood Wet chemical glucose dehydro-genase
QC lockout; op-erator ID; con-trol lot number; reagent lot number; date/time; result; range; pass/fail; comment code
Certified oper-ator ID and pa-tient ID entry, settings and memory erase functions may be password protected
5 µl Absorbance pho-tometry; Glucose dehydrogenase
40–240 sec-onds
Ethernet or USB to PC or laptop for full bi-direction-al communica-tion providing downloading and configura-tion features
Fully net-workable “out of the box”; may be inter-faced to LIS/HIS using third party software
LIS connectivity through third par-ty vendor
No Yes Yes No No Lab quality results at the point of care; cleared for screening, diagnosing and moni-toring of diabetes; full data, operator and an-alyzer management funtionality; off meter dosage; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Plasma/Low Hb Photometer
Plasma hemo-globin testing
6.29 in x 8.25 in x 3.54 in; 2 lbs
Portable; single-use testing: mi-crocuvette
Hospital lab, sur-gery and blood banks
Single analyte Plasma, serum, aqueous so-lutions, stored blood
International Ref-erence Method (ICSH)
Liquid controls available
20 µl Absorbance pho-tometry; Azidemet-hemoglobin
<1 minute Lab quality results at the point of care; mea-sure at two wave-lengths to correct for turbidity; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Donor Hb Checker Pho-tometer
Hemoglo-bin testing for blood donor screening
6.29 in x 8.25 in x 3.54 in; 2 lbs
Portable; single-use testing: mi-crocuvette
Blood donor col-lection facilities
Single analyte Whole blood International Ref-erence Method (ICSH)
Control cuvette to verify cali-bration
10 µl Absorbance pho-tometry; measures the absorbance of hemolyzed blood at the Hb/HbO2 isobestic point
<1 minute Lab quality results at the point of care; mea-sure at two wave-lengths to correct for turbidity; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Albumin 201 Analyzer (pend-ing FDA clear-ance)
Microalbunin-uria screen-ing for point of care
6.89 in x 2.56 in x 4.53 in; .77 lbs
Portable; single-use testing: mi-crocuvette
Physician office and hospital
Single analyte Urine Tubidimetric method using CRM 470 (cert-fied reference material)
Automatic self-test
18 µl Absorbance pho-tometry; immmuno chemical reaction
<90 seconds Lab-quality results at the point of care; for screening, diagnosing and monitoring for mi-croalbuminuria
HemoSense, Inc. 651 River Oaks Parkway, San Jose, CA 95134
Contact: Tim Still, EVP Sales & Marketing; 408-719-1393 fax: 408-719-1184
E-mail:[email protected]
Web Site: www.hemosense.com
INRatio PT/INR Monitoring Sys-tem
Prothrombin Time/INR
6.125 x 3 x 2.2 in / 155.6 x 76 x 55.8 mm / 8.1 oz. / 229g / MSRP $1,595 POC; $1,995 Pa-tient Self Test
Portable size, single strip use
Point-of-Care Testing
PT, INR Fingerstick blood Calibrated to WHO standards
2 levels of quantitative QC onboard with reportable re-sults
1 drop ~15µL fresh whole capil-lary blood
Electrochemical impedance based
<2 minutes Yes, export re-sults to printer or software
RS232 cable Data Port to con-nect to computer or printer
Yes 2 levels of quantita-tive QC onboard with results displayed; test strip storage non-re-frigerated up to 12 months; no exter-nal or liquid controls required; no special blood collection devic-es required; individual-ly packaged strips
Inverness Medical Professional Diagnostics
(800) 637-3717Web site: www.invernessmedicalpd.com
PocketChemTM UA Compact Urine Alyzer
Ultra-porta-ble Urine Strip Reader
9x5x1 inches, 1.5 lbs/
reflectance spectropho-tometry
Nursing units, ED/ER, laborato-ry, POL
Glucose, Protein, Blood, Nitrites, pH, Urobilino-gen, Ketones, Bilirubin, Leuko-cytes, Specific Gravity
Urine Glucose - double sequential en-zyme Protein - protein error reaction Bilirubin - Azo coupling Urobilinogen - Azo coupling pH - mixed pH indicator S.G. - cation ex-traction Blood - pseudo-peroxidase Ketone - Legal reaction Nitrite - Griess reaction Leukocytes - es-terase activity
Exterl QC ma-terial, also HCG pos
Option to input measurement and PT ID
Enough to cover all pads
Triple wavelength, dedicated LED
60 seconds RS-232 inter-face
External RS-232 interface None Pocket sized; automatic correction for pH; automatic correction for temp; automatic compensa-tion for color; automatic calibration with standard pad; allows for left or right-handed setup
AcceavaTM H. pylori
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
H. pylori rap-id test
Whole blood, se-rum, plasma
Onboard proce-dural control
Option to input measurement and PT ID
10 ul for se-rum/plas-ma 25 ul for whole blood
Detection of IgG, IgA, and IgM anti-bodies to H. pylori
10 minutes Detection of IgG, IgA, and IgM antibodies; 95.9% sensitivity; 89.1% specificity
Clearview H. pylori
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
H. pylori rap-id test
Whole blood, se-rum, plasma
1 drop (~20 ul) serum/plasma 2 drops (~40 ul) whole blood
Detection of IgG antibodies to H. pylori
1 to 5 minutes 92.6% sensitivity; 82.4% specificity
ImmunoCar-dSTAT! Rota-virus
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
Rotavirus rap-id test
Stool 25 ul Detection of Group A Rotavirus antigen in stool
10 minutes Easy, clean procedure; 93.1% sensitivity; 95.8% specificity
BioStar OIA Cd-TOX A
Optical Im-munoassay
Nursing units, ED/ER, laborato-ry, POL
Clostridium difi-cile toxin A rap-id test
Stool Onboard proce-dural control
Scrape with sam-ple brush or 220 ul liquid stool
Detection of CD Tox A enterotoxin
15 minutes Easy, clean procedure
Clearview Cd-TOX A
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
Clostridium difi-cile toxin A rap-id test
Stool 125 ul stool filtrate
Detection of CD Tox A enterotoxin
30 minutes
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th
an
nu
al
po
ct
bu
yer
s g
uid
e
www.advanceweb.com advance/Laboratory • April 2006 | 83
| s t o r y tA g L i n e |
HemoCue Inc.(continued)
Glucose 201 DM Analyzer
Glucose test-ing with data management features
3.66 in x 6.7 in x 1.97 in; .77 lbs
Handheld; portable; single-use testing: mi-crocuvette
Hospital Single analyte Whole blood Wet chemical glucose dehydro-genase
QC lockout; op-erator ID; con-trol lot number; reagent lot number; date/time; result; range; pass/fail; comment code
Certified oper-ator ID and pa-tient ID entry, settings and memory erase functions may be password protected
5 µl Absorbance pho-tometry; Glucose dehydrogenase
40–240 sec-onds
Ethernet or USB to PC or laptop for full bi-direction-al communica-tion providing downloading and configura-tion features
Fully net-workable “out of the box”; may be inter-faced to LIS/HIS using third party software
LIS connectivity through third par-ty vendor
No Yes Yes No No Lab quality results at the point of care; cleared for screening, diagnosing and moni-toring of diabetes; full data, operator and an-alyzer management funtionality; off meter dosage; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Plasma/Low Hb Photometer
Plasma hemo-globin testing
6.29 in x 8.25 in x 3.54 in; 2 lbs
Portable; single-use testing: mi-crocuvette
Hospital lab, sur-gery and blood banks
Single analyte Plasma, serum, aqueous so-lutions, stored blood
International Ref-erence Method (ICSH)
Liquid controls available
20 µl Absorbance pho-tometry; Azidemet-hemoglobin
<1 minute Lab quality results at the point of care; mea-sure at two wave-lengths to correct for turbidity; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Donor Hb Checker Pho-tometer
Hemoglo-bin testing for blood donor screening
6.29 in x 8.25 in x 3.54 in; 2 lbs
Portable; single-use testing: mi-crocuvette
Blood donor col-lection facilities
Single analyte Whole blood International Ref-erence Method (ICSH)
Control cuvette to verify cali-bration
10 µl Absorbance pho-tometry; measures the absorbance of hemolyzed blood at the Hb/HbO2 isobestic point
<1 minute Lab quality results at the point of care; mea-sure at two wave-lengths to correct for turbidity; minimum of interferences; no lot-to-lot variation; no re-calibration needed
Albumin 201 Analyzer (pend-ing FDA clear-ance)
Microalbunin-uria screen-ing for point of care
6.89 in x 2.56 in x 4.53 in; .77 lbs
Portable; single-use testing: mi-crocuvette
Physician office and hospital
Single analyte Urine Tubidimetric method using CRM 470 (cert-fied reference material)
Automatic self-test
18 µl Absorbance pho-tometry; immmuno chemical reaction
<90 seconds Lab-quality results at the point of care; for screening, diagnosing and monitoring for mi-croalbuminuria
HemoSense, Inc. 651 River Oaks Parkway, San Jose, CA 95134
Contact: Tim Still, EVP Sales & Marketing; 408-719-1393 fax: 408-719-1184
E-mail:[email protected]
Web Site: www.hemosense.com
INRatio PT/INR Monitoring Sys-tem
Prothrombin Time/INR
6.125 x 3 x 2.2 in / 155.6 x 76 x 55.8 mm / 8.1 oz. / 229g / MSRP $1,595 POC; $1,995 Pa-tient Self Test
Portable size, single strip use
Point-of-Care Testing
PT, INR Fingerstick blood Calibrated to WHO standards
2 levels of quantitative QC onboard with reportable re-sults
1 drop ~15µL fresh whole capil-lary blood
Electrochemical impedance based
<2 minutes Yes, export re-sults to printer or software
RS232 cable Data Port to con-nect to computer or printer
Yes 2 levels of quantita-tive QC onboard with results displayed; test strip storage non-re-frigerated up to 12 months; no exter-nal or liquid controls required; no special blood collection devic-es required; individual-ly packaged strips
Inverness Medical Professional Diagnostics
(800) 637-3717Web site: www.invernessmedicalpd.com
PocketChemTM UA Compact Urine Alyzer
Ultra-porta-ble Urine Strip Reader
9x5x1 inches, 1.5 lbs/
reflectance spectropho-tometry
Nursing units, ED/ER, laborato-ry, POL
Glucose, Protein, Blood, Nitrites, pH, Urobilino-gen, Ketones, Bilirubin, Leuko-cytes, Specific Gravity
Urine Glucose - double sequential en-zyme Protein - protein error reaction Bilirubin - Azo coupling Urobilinogen - Azo coupling pH - mixed pH indicator S.G. - cation ex-traction Blood - pseudo-peroxidase Ketone - Legal reaction Nitrite - Griess reaction Leukocytes - es-terase activity
Exterl QC ma-terial, also HCG pos
Option to input measurement and PT ID
Enough to cover all pads
Triple wavelength, dedicated LED
60 seconds RS-232 inter-face
External RS-232 interface None Pocket sized; automatic correction for pH; automatic correction for temp; automatic compensa-tion for color; automatic calibration with standard pad; allows for left or right-handed setup
AcceavaTM H. pylori
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
H. pylori rap-id test
Whole blood, se-rum, plasma
Onboard proce-dural control
Option to input measurement and PT ID
10 ul for se-rum/plas-ma 25 ul for whole blood
Detection of IgG, IgA, and IgM anti-bodies to H. pylori
10 minutes Detection of IgG, IgA, and IgM antibodies; 95.9% sensitivity; 89.1% specificity
Clearview H. pylori
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
H. pylori rap-id test
Whole blood, se-rum, plasma
1 drop (~20 ul) serum/plasma 2 drops (~40 ul) whole blood
Detection of IgG antibodies to H. pylori
1 to 5 minutes 92.6% sensitivity; 82.4% specificity
ImmunoCar-dSTAT! Rota-virus
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
Rotavirus rap-id test
Stool 25 ul Detection of Group A Rotavirus antigen in stool
10 minutes Easy, clean procedure; 93.1% sensitivity; 95.8% specificity
BioStar OIA Cd-TOX A
Optical Im-munoassay
Nursing units, ED/ER, laborato-ry, POL
Clostridium difi-cile toxin A rap-id test
Stool Onboard proce-dural control
Scrape with sam-ple brush or 220 ul liquid stool
Detection of CD Tox A enterotoxin
15 minutes Easy, clean procedure
Clearview Cd-TOX A
lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
Clostridium difi-cile toxin A rap-id test
Stool 125 ul stool filtrate
Detection of CD Tox A enterotoxin
30 minutes
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th a
nn
ua
l po
ct b
uyer
s g
uid
e6th annual poct buyers guide
84 | advance/Laboratory • April 2006 www.advanceweb.com
Inverness Medical Professional Diagnostics(continued)
Clearview UL-TRA FOB
Lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
Rapid immuno-assay for Fecal Occult Blood
Stool onboard proce-dural control
scrape with sample probe
specific for human hgb in stool
1-5 minutes Easy, clean procedure; specific for human hgb; no dietary restrictions; 50 ng limit of de-tection; 99.3% sensitivity; 98.9% accuracy; separate PT take; home sample kits
STREP A OIA MAX
Optical Im-munoassay
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 5 minutes Yes Yes
Acceava GAS Lateral flow ICT
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
Clearview Exact Strep A
Lateral flow ICT
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
NOW Strep A Lateral flow ICT, Clam-shell
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
BioStar OIA FLU Optical Im-munoassay
Microbiology NP Swab, sal As-pirate, Throat Swab, Sputum
Positive and negative con-trols in kit
Immunoassay 18 minutes Yes Yes
BioStar OIA FLU A/B
Optical Im-munoassay
Microbiology NP Swab, sal As-pirate, Throat Swab, Sputum
Positive and negative con-trols in kit
Immunoassay 18 minutes Yes Yes
BinaxNOW Influ-enxa A&B
Lateral flow ICT, Clam-shell
Microbiology NP Swab, sal Wash
Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
Clearview Mono Lateral flow ICT
Microbiology Plasma, Serum, Whole Blood
Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
Acceava Mono Lateral flow ICT
Microbiology Plasma, Serum, Whole Blood
Positive and negative con-trols in kit
Immunoassay 10 minutes Yes Yes
Clearview D-Dimer
Lateral flow ICT
Microbiology Whole blood, Plasma
Positive and negative con-trols in kit
Immunoassay Yes Yes
Legionella Uri-nary Antigen test
Lateral flow ICT, Clam-shell
Hospital/refer-ence lab
Urine Culture
Streptococcus pneumoniae An-tigen test
Lateral flow ICT, Clam-shell
Hospital/refer-ence lab
Urine/CSF Blood Culture
Influenza A & B Combo test (Moderately Complex)
Lateral flow ICT, Clam-shell
Hospital/refer-ence lab
Culture/DFA
Nanogen Inc.
Contact: Nancy T. Rector(416) 798-0631
E-mail: [email protected]
Web Site: www.nanogen.com
i-Lynx™ System
Data Capture Device
Device: 8 in x 7.5 in x 4.6 in; Dock-ing Station: 9.25 in x 5 in x 4.25 in; List $5,600
Handheld Emergency de-partment or laboratory/cardi-ologist office
Cardiac markers Open architecture Kit related Opera-tor lockout timed assay mode
Kit related Kit related 5-15 minutes Yes Yes LAN, TCPIP, USB Future ca-pability
Yes Yes Yes Yes QC and operator data capture • Software compatible and connectivity ready with POC industry soft-ware solutions • Security log in and lockout features • Instant or multi test mode to allow for high throughput • Hand-held device for testing at the patient bedside • True walk away mode or instant multi-test option • Easy to use PDA-style touch screen • Integrated universal barcode scanner • Docking station built-in printer
Cardi-ac STATus™ Myoglobin/Tro-ponin I, CKMB Cardiac Mark-ers
Lateral flow membrane
Tandem (TnI/Myo/CKMB), $51.00
Kit test Emergency de-partment or laboratory/cardi-ologist office
TnI/Myo/CKMB Whole blood, se-rum or plasma
Beckman Ac-cess: TnI Abbott IMX: CKMB Dade Opus: Myoglobin
Internal QC 150 mL of whole blood; serum or plasma
Immunochromato-graphic
5 minutes to a positive; 15 minutes to a negative
When used in conjunc-tion with the i-Lynx™ Sys-tem
When used in conjunc-tion with the i-Lynx™ System
When used in conjunction with the i-Lynx™ System
When used in conjunc-tion with the i-Lynx™System
Quickly and accurate-ly identify heart attacks in patients experienc-ing chest pain with Spectral’s Cardiac STA-Tus™. • Rapid Results— Qualitative cardiac marker results in 15 minutes without instru-mentation
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th
an
nu
al
po
ct
bu
yer
s g
uid
e
www.advanceweb.com advance/Laboratory • April 2006 | 85
Inverness Medical Professional Diagnostics(continued)
Clearview UL-TRA FOB
Lateral flow ICT
Nursing units, ED/ER, laborato-ry, POL
Rapid immuno-assay for Fecal Occult Blood
Stool onboard proce-dural control
scrape with sample probe
specific for human hgb in stool
1-5 minutes Easy, clean procedure; specific for human hgb; no dietary restrictions; 50 ng limit of de-tection; 99.3% sensitivity; 98.9% accuracy; separate PT take; home sample kits
STREP A OIA MAX
Optical Im-munoassay
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 5 minutes Yes Yes
Acceava GAS Lateral flow ICT
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
Clearview Exact Strep A
Lateral flow ICT
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
NOW Strep A Lateral flow ICT, Clam-shell
Microbiology Throat swab Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
BioStar OIA FLU Optical Im-munoassay
Microbiology NP Swab, sal As-pirate, Throat Swab, Sputum
Positive and negative con-trols in kit
Immunoassay 18 minutes Yes Yes
BioStar OIA FLU A/B
Optical Im-munoassay
Microbiology NP Swab, sal As-pirate, Throat Swab, Sputum
Positive and negative con-trols in kit
Immunoassay 18 minutes Yes Yes
BinaxNOW Influ-enxa A&B
Lateral flow ICT, Clam-shell
Microbiology NP Swab, sal Wash
Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
Clearview Mono Lateral flow ICT
Microbiology Plasma, Serum, Whole Blood
Positive and negative con-trols in kit
Immunoassay 6 minutes Yes Yes
Acceava Mono Lateral flow ICT
Microbiology Plasma, Serum, Whole Blood
Positive and negative con-trols in kit
Immunoassay 10 minutes Yes Yes
Clearview D-Dimer
Lateral flow ICT
Microbiology Whole blood, Plasma
Positive and negative con-trols in kit
Immunoassay Yes Yes
Legionella Uri-nary Antigen test
Lateral flow ICT, Clam-shell
Hospital/refer-ence lab
Urine Culture
Streptococcus pneumoniae An-tigen test
Lateral flow ICT, Clam-shell
Hospital/refer-ence lab
Urine/CSF Blood Culture
Influenza A & B Combo test (Moderately Complex)
Lateral flow ICT, Clam-shell
Hospital/refer-ence lab
Culture/DFA
Nanogen Inc.
Contact: Nancy T. Rector(416) 798-0631
E-mail: [email protected]
Web Site: www.nanogen.com
i-Lynx™ System
Data Capture Device
Device: 8 in x 7.5 in x 4.6 in; Dock-ing Station: 9.25 in x 5 in x 4.25 in; List $5,600
Handheld Emergency de-partment or laboratory/cardi-ologist office
Cardiac markers Open architecture Kit related Opera-tor lockout timed assay mode
Kit related Kit related 5-15 minutes Yes Yes LAN, TCPIP, USB Future ca-pability
Yes Yes Yes Yes QC and operator data capture • Software compatible and connectivity ready with POC industry soft-ware solutions • Security log in and lockout features • Instant or multi test mode to allow for high throughput • Hand-held device for testing at the patient bedside • True walk away mode or instant multi-test option • Easy to use PDA-style touch screen • Integrated universal barcode scanner • Docking station built-in printer
Cardi-ac STATus™ Myoglobin/Tro-ponin I, CKMB Cardiac Mark-ers
Lateral flow membrane
Tandem (TnI/Myo/CKMB), $51.00
Kit test Emergency de-partment or laboratory/cardi-ologist office
TnI/Myo/CKMB Whole blood, se-rum or plasma
Beckman Ac-cess: TnI Abbott IMX: CKMB Dade Opus: Myoglobin
Internal QC 150 mL of whole blood; serum or plasma
Immunochromato-graphic
5 minutes to a positive; 15 minutes to a negative
When used in conjunc-tion with the i-Lynx™ Sys-tem
When used in conjunc-tion with the i-Lynx™ System
When used in conjunction with the i-Lynx™ System
When used in conjunc-tion with the i-Lynx™System
Quickly and accurate-ly identify heart attacks in patients experienc-ing chest pain with Spectral’s Cardiac STA-Tus™. • Rapid Results— Qualitative cardiac marker results in 15 minutes without instru-mentation
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th a
nn
ua
l po
ct b
uyer
s g
uid
e6th annual poct buyers guide
86 | advance/Laboratory • April 2006 www.advanceweb.com
Nanogen Inc.(continued)
• Time critical diag-nostic information, in accordance with AHA and ACC guidelines • Stored at room tem-perature • Easy to use—No de-capping• Simple to read • Utilizes the re-nowned 8I-7 antibody in a sandwich assay for superior Troponin I• Capture and avoids interfering factors
Cardi-ac STATus™ Myoglobin/Troponin I Cardiac Mark-ers
Lateral Flow Membrane
TnI/ Myo, $40.80
Kit test Emergency de-partment or laboratory/cardi-ologist office
Troponin I/Myo-globin
Whole blood, se-rum or plasma
Beckman Ac-cess: TnI Dade Opus: Myo-globin
Internal QC 150 mL of whole blood; serum or plasma
Immunochromato-graphic
5 minutes to a positive; 15 minutes to a negative
When used in conjunc-tion with the i-Lynx™ Sys-tem
When used in conjunc-tion with the i-Lynx™ System
When used in conjunction with the i-Lynx™ System
When used in conjunc-tion with the i-Lynx™ System
See above
Cardi-ac STATus™ Troponin I Car-diac Marker
Lateral Flow Membrane
TnI $35.70 / kit
Kit test Emergency de-partment or laboratory/cardi-ologist office
Troponin I Whole blood, se-rum or plasma
Beckman Ac-cess: TnI
Internal QC 150 mL of whole blood; serum or plasma
Immunochromato-graphic
5 minutes to a positive; 15 minutes to a negative
When used in conjunc-tion with the i-Lynx™ Sys-tem
When used in conjunc-tion with the i-Lynx™ System
When used in conjunction with the i-Lynx™ System
When used in conjunc-tion with the i-Lynx™ System
See above
Nova Biomedical Contact:
Harlan Polishook (781) 894-0800
E-mail: [email protected]
Web Site: www.novabiomedical.com
Stat Profile Criti-cal Care Xpress
Blood gas/electrolyte/chemistry
17.2 in x 22.3 in x 17.3 in, 53 lbs; $25,000–$59,000
Transportable, multi-use, microsensor-based
Laboratory, re-spiratory care, ICU, OR, ED
pH, PCO2, PO2, SO2%, Hct, Hb, Na+, K+, Cl-, Ca++, Mg++, Glucose, Lac-tate, BUN, Cre-atinine, HHb, O2Hb, MetHb, COHb
Whole blood, se-rum, plasma
Conforms to ac-cepted laboratory standards from a variety of industry organizations
Onboard liquid QC; QC lock-out; ability to store, date, time stamp, print pa-tient and QC re-sults
Multiple lay-er; user con-figurable, including pa-tient ID, medical record number, operator ID, PIN number
60-210 mi-croliters (de-pending on menu se-lected)
pH, Na+, K+, Cl, Ca++, Mg++ — Direct ISE; glucose, lactate, creati-nine — enzyme/amperometric; PCO2 —Sever-inghaus; PO2 — amperometeric; SO2%— optical, reflectance; Hct — conductivity; Hb — multi-wavelength, reflectance; BUN — enzyme/direct ISE; HHb, O2Hb, MetHb, COHb -- spectophotometry
62 seconds (high through-put); 134 sec-onds (routine throughput)
“Unlimited” pa-tient and QC database on-board that is download-able or direct connected to LIS/HIS
Yes TCP/IP; Ether-net; USB; RF net-works; serial RS-232; bi-direc-tional communi-cations; remote control for cal-ibrations; QC, maintenance and troubleshooting; remote review of results prior to release
Yes Stat Pro-file Criti-cal Care Xpress
Yes Yes Yes Color touch screen; in-tegrated co-oximeter; open software archi-tecture; onboard data management; auto-mated, onboard quality control; sealed waste system; auto-monitor-ing of QC and reagent packs; tankless gas calibration; automated maintenance
Radiometer America Inc.
Contact: (440) 871-8900
E-mail: [email protected]
Web Site: www.radiometeramerica.com
ABL80 FLEX Blood gas, electrolytes and glucose
16 in x 9 in x 11 in
Portable with built-in bat-tery; car-tridge-based consumable; no user main-tenance
CVOR, OR, ICU, ER, NICU, re-spiratory de-partments, laboratory
pH, pO2, pCO2, Ca++, Cl-, K+, Na+, Hct, cGlu
Heparinized, whole blood
Validated to IFCC guidelines
Automatic, on-board QC sys-tem with automatic lock-out for parame-ter that fails
5 user-defined access levels
70 uL See reference manual
120 seconds Wireless, on-board CD R/RW drive
Yes ASTM, HL7, TCP/IP, POCT-1A
Yes Yes Yes Yes Yes Part of Radiometer’s first automatic blood gas analysis system that uses pre-bar-coded samplers and FLEXLINK software to ensure accurate pa-tient and sample iden-tification; portable mixing device ensures fast and complete mix-ing prior to analysis
NPT7 Blood gas and CO-oximetry
10 in x 13 in x 17 in
Portable with built-in bat-tery; car-tridge-based consumable; no user main-tenance
ICU, ER, re-spiratory de-partments, laboratory
pO2, pCO2, pH, tHb, O2Hb, metHb, HHb
Heparinized, whole blood
Validated to IFCC guidelines
QualityGuard System au-tomatically checks analyzer and each sam-ple cuvette be-fore and during analysis
User logon, manager as-signs levels of access, QC lockout, result repression
90 uL Patented optical technology; mea-surements are achieved through technologies of modulation, infra-red spectroscopy, 128-wavelength spectroscopy and phosphorescence quenching
Approx. 1 minute
Built-in PCMCIA memory card, Ethernet and serial interface to LIS and all external data management systems. RA-DIANCE STAT Analyzer Man-agement Sys-tem.
Both ASTM Serial and Ethernet
No Yes, with RADIANCE STAT Ana-lyzer Man-agement System
Yes Yes Yes, with RA-DIANCE STAT Analyzer Management System
The only discrete car-tridge-based blood gas analyzer on the mar-ket to verify the perfor-mance of the cartridge prior to analysis; Qual-ityGuard QC system; battery operation; three-month in-use cartridge life; minimal waste; full CO-Oxim-tery panels with each blood gas; mainte-nance free
Response Biomedical Corp. Contact:
(604) 456-6010; Toll Free: (888) 591-5577
E-mail: [email protected]
Web Site: www.responsebio.com
RAMP Rapid Ana-lyte Measure-ment Platform (RAMP)—A Fluorescence Reader
27 cm (11”) wide x 25 cm (10”) deep x 15 cm (6”) high; Weight: 4.6 lbs
Quantitative Immunochro-matographic Analyzer
Point of care—emergency de-partment
Currently avail-able: Tropo-nin I, CK-MB and Myoglobin. Coming in 2006: Nt-ProBNP (un-der license from Roche). Under development: Flu A, Flu B and RSV
Whole blood System QC Fully program-mable self di-agnostics (IQC), lot verifica-tion and expi-ry information for up to 50 as-say lots; pow-er-on self-tests include: calibra-tion verification, clock, trans-port mecha-nism, optics function and re-chargeable bat-tery test
Supervisor-con-trolled functions such as oper-ator lists and lockout, QC in-terval, IQC in-terval and internal clock; barcode wand data entry for patient ID and user ID
70 µL Approx. 15 minutes
Assay results can be down-loaded to print-er or PC
PC, printer, reader-to-reader
Download results to PC or via Tel-cor for POC or LIS connectivity
Yes Yes Quantitative, rapid, with <10% CVs across assay ranges; very sensitive Troponin I as-say; discrete cartridge system for running only those tests re-quested; low cost per test, portable, ambula-tory, barcode wand for patient and operator ID entry, 500 patient re-sults and 250 user ca-pacity
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th
an
nu
al
po
ct
bu
yer
s g
uid
e
www.advanceweb.com advance/Laboratory • April 2006 | 87
Nanogen Inc.(continued)
• Time critical diag-nostic information, in accordance with AHA and ACC guidelines • Stored at room tem-perature • Easy to use—No de-capping• Simple to read • Utilizes the re-nowned 8I-7 antibody in a sandwich assay for superior Troponin I• Capture and avoids interfering factors
Cardi-ac STATus™ Myoglobin/Troponin I Cardiac Mark-ers
Lateral Flow Membrane
TnI/ Myo, $40.80
Kit test Emergency de-partment or laboratory/cardi-ologist office
Troponin I/Myo-globin
Whole blood, se-rum or plasma
Beckman Ac-cess: TnI Dade Opus: Myo-globin
Internal QC 150 mL of whole blood; serum or plasma
Immunochromato-graphic
5 minutes to a positive; 15 minutes to a negative
When used in conjunc-tion with the i-Lynx™ Sys-tem
When used in conjunc-tion with the i-Lynx™ System
When used in conjunction with the i-Lynx™ System
When used in conjunc-tion with the i-Lynx™ System
See above
Cardi-ac STATus™ Troponin I Car-diac Marker
Lateral Flow Membrane
TnI $35.70 / kit
Kit test Emergency de-partment or laboratory/cardi-ologist office
Troponin I Whole blood, se-rum or plasma
Beckman Ac-cess: TnI
Internal QC 150 mL of whole blood; serum or plasma
Immunochromato-graphic
5 minutes to a positive; 15 minutes to a negative
When used in conjunc-tion with the i-Lynx™ Sys-tem
When used in conjunc-tion with the i-Lynx™ System
When used in conjunction with the i-Lynx™ System
When used in conjunc-tion with the i-Lynx™ System
See above
Nova Biomedical Contact:
Harlan Polishook (781) 894-0800
E-mail: [email protected]
Web Site: www.novabiomedical.com
Stat Profile Criti-cal Care Xpress
Blood gas/electrolyte/chemistry
17.2 in x 22.3 in x 17.3 in, 53 lbs; $25,000–$59,000
Transportable, multi-use, microsensor-based
Laboratory, re-spiratory care, ICU, OR, ED
pH, PCO2, PO2, SO2%, Hct, Hb, Na+, K+, Cl-, Ca++, Mg++, Glucose, Lac-tate, BUN, Cre-atinine, HHb, O2Hb, MetHb, COHb
Whole blood, se-rum, plasma
Conforms to ac-cepted laboratory standards from a variety of industry organizations
Onboard liquid QC; QC lock-out; ability to store, date, time stamp, print pa-tient and QC re-sults
Multiple lay-er; user con-figurable, including pa-tient ID, medical record number, operator ID, PIN number
60-210 mi-croliters (de-pending on menu se-lected)
pH, Na+, K+, Cl, Ca++, Mg++ — Direct ISE; glucose, lactate, creati-nine — enzyme/amperometric; PCO2 —Sever-inghaus; PO2 — amperometeric; SO2%— optical, reflectance; Hct — conductivity; Hb — multi-wavelength, reflectance; BUN — enzyme/direct ISE; HHb, O2Hb, MetHb, COHb -- spectophotometry
62 seconds (high through-put); 134 sec-onds (routine throughput)
“Unlimited” pa-tient and QC database on-board that is download-able or direct connected to LIS/HIS
Yes TCP/IP; Ether-net; USB; RF net-works; serial RS-232; bi-direc-tional communi-cations; remote control for cal-ibrations; QC, maintenance and troubleshooting; remote review of results prior to release
Yes Stat Pro-file Criti-cal Care Xpress
Yes Yes Yes Color touch screen; in-tegrated co-oximeter; open software archi-tecture; onboard data management; auto-mated, onboard quality control; sealed waste system; auto-monitor-ing of QC and reagent packs; tankless gas calibration; automated maintenance
Radiometer America Inc.
Contact: (440) 871-8900
E-mail: [email protected]
Web Site: www.radiometeramerica.com
ABL80 FLEX Blood gas, electrolytes and glucose
16 in x 9 in x 11 in
Portable with built-in bat-tery; car-tridge-based consumable; no user main-tenance
CVOR, OR, ICU, ER, NICU, re-spiratory de-partments, laboratory
pH, pO2, pCO2, Ca++, Cl-, K+, Na+, Hct, cGlu
Heparinized, whole blood
Validated to IFCC guidelines
Automatic, on-board QC sys-tem with automatic lock-out for parame-ter that fails
5 user-defined access levels
70 uL See reference manual
120 seconds Wireless, on-board CD R/RW drive
Yes ASTM, HL7, TCP/IP, POCT-1A
Yes Yes Yes Yes Yes Part of Radiometer’s first automatic blood gas analysis system that uses pre-bar-coded samplers and FLEXLINK software to ensure accurate pa-tient and sample iden-tification; portable mixing device ensures fast and complete mix-ing prior to analysis
NPT7 Blood gas and CO-oximetry
10 in x 13 in x 17 in
Portable with built-in bat-tery; car-tridge-based consumable; no user main-tenance
ICU, ER, re-spiratory de-partments, laboratory
pO2, pCO2, pH, tHb, O2Hb, metHb, HHb
Heparinized, whole blood
Validated to IFCC guidelines
QualityGuard System au-tomatically checks analyzer and each sam-ple cuvette be-fore and during analysis
User logon, manager as-signs levels of access, QC lockout, result repression
90 uL Patented optical technology; mea-surements are achieved through technologies of modulation, infra-red spectroscopy, 128-wavelength spectroscopy and phosphorescence quenching
Approx. 1 minute
Built-in PCMCIA memory card, Ethernet and serial interface to LIS and all external data management systems. RA-DIANCE STAT Analyzer Man-agement Sys-tem.
Both ASTM Serial and Ethernet
No Yes, with RADIANCE STAT Ana-lyzer Man-agement System
Yes Yes Yes, with RA-DIANCE STAT Analyzer Management System
The only discrete car-tridge-based blood gas analyzer on the mar-ket to verify the perfor-mance of the cartridge prior to analysis; Qual-ityGuard QC system; battery operation; three-month in-use cartridge life; minimal waste; full CO-Oxim-tery panels with each blood gas; mainte-nance free
Response Biomedical Corp. Contact:
(604) 456-6010; Toll Free: (888) 591-5577
E-mail: [email protected]
Web Site: www.responsebio.com
RAMP Rapid Ana-lyte Measure-ment Platform (RAMP)—A Fluorescence Reader
27 cm (11”) wide x 25 cm (10”) deep x 15 cm (6”) high; Weight: 4.6 lbs
Quantitative Immunochro-matographic Analyzer
Point of care—emergency de-partment
Currently avail-able: Tropo-nin I, CK-MB and Myoglobin. Coming in 2006: Nt-ProBNP (un-der license from Roche). Under development: Flu A, Flu B and RSV
Whole blood System QC Fully program-mable self di-agnostics (IQC), lot verifica-tion and expi-ry information for up to 50 as-say lots; pow-er-on self-tests include: calibra-tion verification, clock, trans-port mecha-nism, optics function and re-chargeable bat-tery test
Supervisor-con-trolled functions such as oper-ator lists and lockout, QC in-terval, IQC in-terval and internal clock; barcode wand data entry for patient ID and user ID
70 µL Approx. 15 minutes
Assay results can be down-loaded to print-er or PC
PC, printer, reader-to-reader
Download results to PC or via Tel-cor for POC or LIS connectivity
Yes Yes Quantitative, rapid, with <10% CVs across assay ranges; very sensitive Troponin I as-say; discrete cartridge system for running only those tests re-quested; low cost per test, portable, ambula-tory, barcode wand for patient and operator ID entry, 500 patient re-sults and 250 user ca-pacity
Company Info Product Name Type of Analyzer
Size and Weight/Cost
Type of Design
Primary Area of Use
Test Menu Sample Type Product Reference Methods
Error Tolerances to Measure Performance
QC Features Security Features
Sample Size Required
Analytical Principle for Each Analyte
Turnaround Time for Results
Downloading Capabilities
Internal or External Connectivity
Connectivity Options
Availability of Wireless Communi-cation
Compliance with CLSI-POCT1A
Utilization of CLSI Technical Performance Standards
Utilization of CLSI Automation Standards
Remote Lock-out/Operation
Distinguishing Features
6th a
nn
ua
l po
ct b
uyer
s g
uid
e6th annual poct buyers guide
88 | advance/Laboratory • April 2006 www.advanceweb.com
Company Info Product Name QC Features Distinguishing Features
6th
an
nu
al
po
ct
bu
yer
s g
uid
e6th annual poct buyers guide
Response Biomedical Corp. (continued)
Software QC unauthorized user lock-out; external QC overdue result flag; patient re-sults output includes: pa-tient result, pa-tient ID, user ID, date, time, lot number, serial number
Test Cartridge QC Each test car-tridge uses an internal con-trol zone and the RAMP Ratio for calibrating each test. This process miti-gates variabili-ty and reduces CV’s. Each car-tridge is bar coded with lot expiry and as-say information. Multiple safe-guards to miti-gate procedural errors.
Security Fea-tures: Supervi-sor-controlled functions such as operator lists and lockout, QC interval, IQC in-terval and in-ternal clock. Barcode Wand data entry for patient ID and user ID.
RNA Medical; A Division of Bionostics Inc.
Contact: Paul F. Shea
Phone: 978-772-9070
Fax: 978-772-9071
E-mail: [email protected]
Web Site: www.RNAMedical.com
Blood gas qual-ity and linear-ity controls; diabetes quali-ty and linearity controls; he-matology and urinalysis con-trols
PeerQC gives the end user the opportuni-ty to record the data and re-ceive a peer comparison within a few minutes
RNA Medical offers differentiated QC so-lutions for your POC market
Roche Diagnostics
9115 Hague RoadIndianapolis, IN 46256
Contact:Ben GreenfieldMarketing Manager
Phone:(317) 521-3088
Web Site:www.roche-diagnostics.us