POCKET RATING GUIDE Generator Sets R

Pocket Rating Guide Gensets_LEXE2576-07

Embed Size (px)

Citation preview

Page 1: Pocket Rating Guide Gensets_LEXE2576-07

POCKET RATING GUIDEGenerator Sets

R

Page 2: Pocket Rating Guide Gensets_LEXE2576-07

OLYMPIAN GENERATOR SETS(DIESEL)

TABLE OF CONTENTS

Olympian International Diesel Ratings

Caterpillar Diesel Ratings

Caterpillar Diesel Rental Ratings

Olympian and Cat Diesel Rating Definitions

Olympian International Gas Ratings

Olympian North America Gas Ratings

Caterpillar Gas Ratings

Olympian and Cat Gas Rating Definitions

Conversion Tables

Notes Page

Caterpillar Offices

4-5

7-12

13

14

16

17

19-22

23

24-34

35

36

Olympian DieselCat Diesel

Olympian GasCat Gas

Color Key:

Page 3: Pocket Rating Guide Gensets_LEXE2576-07

Standby

68691114

16.517.52426354450648088105

Standby

––––131720––304044557294100

112.5

Standby

13.8182222303530334450556588100110150165––

220250275

50 Hz - kVArpm

15001500150030003000300015001500150015001500150015001500150015001500

––

150015001500

Prime

1215.518–––2427364045556488

90.4120–

135.2–

180––

Prime

12.516.520–––2730404550608090100135150––

200230250

60 Hz - ekW

*Ratings at 0.8 pf and 43 deg C (100 deg F).

Gen SetModel

GEP13.5-2GEP18-2GEP22.2

GEPH22-2GEPH30-2GEPH35-2GEP30-1GEP33-1GEP44-5GEP50-5GEP55-1GEP65-5GEP88-1GEP100GEP110GEP150GEP165GEH175GEH188GEH220GEH250GEH275

OLYMPIAN INTERNATIONAL DIESEL RATINGS (cont.)

Standby

131720–––

27.23040455060

70.496100132–

148150.4200––

OLYMPIAN INTERNATIONAL DIESEL RATINGS

**Ratings at 1.0 pf and 32 deg C (90 deg F).

60 Hz - ekW 50 Hz - kVA

Single Phase Output**rpm

15001500300030001500150015003000300015001500150015001500150015001500

Prime

––––12

15.518––27364050658590100

Prime

5.57––101315––2432404558728096

rpm

––––

180018001800

––

18001800180018001800180018001800

Gen SetModel

GEK6SP-1GEK8SP-1

GEKH6SP-1GEKH9SP-1GEP11SP-2GEP14SP-2GEP16SP-2GEPH17SPGEPH24SPGEP26SP1GEP35SP5GEP44SP1GEP50SP5GEP64SP1GEP80SP1GEP88SP1GEP105SP1

54

3-Phase Output*rpm

180018001800

–––

1800180018001800180018001800180018001800

–180018001800

––

Page 4: Pocket Rating Guide Gensets_LEXE2576-07

PrimekVA

275320365365

410

455

500545591635680725–

91091010001000113511351275127513601500160017001825182520002275

ContinuouskVA

––––

––––––––

83091091010101010120612301230

–1500

–1600164017502000

CAT 50 Hz DIESEL RATINGS

Configuration

Low BSFCLow BSFCLow BSFC

EU Stage II, Low BSFC,Low Emissions

EU Stage II, Low BSFC,Low Emissions

EU Stage II, Low BSFC,Low Emissions

EU Stage II, Low BSFC,Low Emissions

Low BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low Emissions

Low BSFCLow BSFCLow BSFCLow BSFC

Low BSFC, Low EmissionsLow BSFC

Low BSFC, Low EmissionsLow BSFCLow BSFC

Low BSFC, Low EmissionsLow BSFC

Low BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low EmissionsLow BSFC, Low Emissions

Low BSFC

Engine Model

3406C3406C3406C

C15 ACERTTM

C15 ACERTTM

C15 ACERTTM

C15 ACERTTM

C18 ACERTTM

C18 ACERTTM

C18 ACERTTM

C18 ACERTTM

3412341234123508

C32 ACERTTM

3508BC32 ACERTTM

35123512B3512B3512B3512B3512B

3516B-HD3512B-HD

35163516

3516B3516B-HDC175-16

1500 rpm

StandbykVA

300350400400

450

500

550

55060065070075080090010001000110011001250125014001400150016001750187520002000225025003000

CAT GENERATOR SETS(DIESEL)

7

Page 5: Pocket Rating Guide Gensets_LEXE2576-07

Prime

11.81618

22.527364554

67.58290

1216.418

22.8273645

54.67290114135

*All ratings at 0.8 pf**All ratings at 1.0 pf

3-Phase Output* - 1800 rpm

CAT 60 Hz DIESEL RATINGS

Model

D13-2SD17-2SD20-4SD25-6SD30-6SD40-4SD50-4SD60-4SD75-4SD90-4SD100-4S

D13-2D18-2D20-4D25-6D30-8D40-4D50-4D60-4D80-4D100-4D125-6D150-8

Single Phase Output** -1800 rpmStandby

13172025304050607590100

131820253040506080100125150

ekW

50 Hz DIESEL RATINGS (cont.)

PrimekVA

5007381050110014001475

–––

2425325048506500

1963––

2600–

39255200

––

–––

–––––

ContinuouskVA

4886389691013122512881368182520252200293844005875

177522252875236332383550472569889313

345646565238

655076388725982513094

1000 rpm

600 rpm

500 rpm

Engine Model

35083508B3512

3512B3516

3516B6CM208CM209CM20

3606360836123616

36066CM258CM25

36089CM25

36123616

12CM3216CM32

6CM328CM329CM32

6CM437CM438CM439CM4312CM43

750 rpm

StandbykVA

–––––––––

2688357553757150

2163––

2863–

43255725

––

–––

–––––

98

Page 6: Pocket Rating Guide Gensets_LEXE2576-07

CAT 60 Hz DIESEL RATINGS (cont.)

Continuous

400520870890110011451325

980130014701650220033004400

EngineModel

35083508B3512

3512B3516

3516B3516B

6CM208CM209CM20

3606360836123616

Prime

42560010001015125012851450

–––

1820242036404840

CAT 60 Hz DIESEL RATINGS (cont.)

900 rpm

1200 rpmStandby

–––––––

–––

2000266040005320

ekW

Prime

225275320

365

410

455

500545591635680725820810910910100011351135127513601360

16001825

1825–

2275––

Continuous ekW

–––

––––––

66074083283089010301010123012301230

14501640

1640–

2050––

Configuration

EPA Tier 3EPA Tier 3

EPA Tier 3, Low BSFC, Low Emissions

EPA Tier 3, Low BSFC, Low Emissions

EPA Tier 3, Low BSFC, Low Emissions

EPA Tier 2, Low BSFC, Low Emissions

EPA Tier 2, Low BSFC, Low Emissions

EPA Tier 2, Low BSFC EPA Tier 2, Low BSFC EPA Tier 2, Low BSFC EPA Tier 2, Low BSFC EPA Tier 2, Low BSFC EPA Tier 2, Low BSFC

Low BSFC, Low EmissionsEPA Tier 2, Low BSFC

Low BSFC, Low EmissionsEPA Tier 2, Low BSFC

Low BSFCLow BSFC

Low BSFC, Low EmissionsLow BSFC, Low Emissions

EPA Tier 2EPA Tier 2, Low BSFC,

Low EmissionsLow BSFC

EPA Tier 2, Low BSFC, Low Emissions

EPA Tier 2EPA Tier 2, Low BSFC,

Low EmissionsEPA Tier 2

EPA Tier 2, Low BSFCEPA Tier 2, Low BSFC

Engine Model

C9 ACERTTM

C9 ACERTTM

C15 ACERTTM

C15 ACERTTM

C15 ACERTTM

C15 ACERTTM

C15 ACERTTM

C18 ACERTTM

C18 ACERTTM

C27 ACERTTM

C27 ACERTTM

C27 ACERTTM

C27 ACERTTM

3508C32 ACERTTM

3508BC32 ACERTTM

35123512B3512

3512B3512C3512B

35163516B

3516C3516B

3516C-HDC175-16C175-16

1800 rpmStandby

250300350

400

450

500

550 (ESP)

550600650700750800–

900–

1000110012501250140015001500

17502000

20002250

250027503000

1110

Page 7: Pocket Rating Guide Gensets_LEXE2576-07

CAT 50 Hz RENTAL UNIT RATINGS

Prime

20274580100135200250

Model

XQE20XQE27XQE45XQE80XQE100XQE135XQE200XQE250

CAT 60 Hz RENTAL UNIT RATINGS

1800 rpmModel

XQ20-2XQ30-4XQ45-2XQ60-4XQ80-2XQ100-4XQ230XQ300XQ500XQ600XQ750XQ1000XQ1500XQ2000

Prime

18274154709021027545554568091013601825

3-Phase Output* - 1500 rpmStandby

––––––––

Standby

2030456080100230300500600750100015002000

*All ratings at 0.8pf

kVA

ekW

CAT 60 Hz DIESEL RATINGS (cont.)

Prime

1525–

2020––

30504040

––

–––

–––––

Continuous

137517301830223025002750366055907450

276537254190

524061106980786010475

EngineModel

36066CM25

36088CM259CM25

36123616

12CM3216CM32

6CM328CM329CM32

6CM437CM438CM439CM4312CM43

720 rpm

600 rpm

514 rpm

Standby

1680–

2200––

33604440

––

–––

–––––

ekW

1312

Page 8: Pocket Rating Guide Gensets_LEXE2576-07

Standby Output available with varying load for the duration of the interruption of the normalsource power. Maximum expected usage equals 500 hours a year. Standby power inaccordance with ISO8528. Fuel stop power in accordance with ISO3046, AS2789, andBS5514 available on request.

Emergency Standy (ESP) Output available with varying load for the duration of the interruption of the normalsource power. Maximum expected usage equals 200 hours a year. Standby power inaccordance with ISO8528. Fuel stop power in accordance with ISO3046, AS2789 andBS5514 available on request.

Prime Output available with varying load for an unlimited time. Prime power in accordance with ISO8528. 10% overload power in accordance with ISO3046, AS2789 and BS5514 is available for emergency use for a maximum of 1 hour in 12, but for no more than 25 hours per year.

Continuous Output available without varying load for an unlimited time. Continuous power in accordance with ISO8528, ISO3046, AS2789, and BS5514.

HD — High DisplacementekW — Generator output at 0.8 pfkVA — Generator output

CAT DIESEL RATING DEFINITIONS:

OLYMPIAN GENERATOR SETS(GAS)

StandbyThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings.Natural gas ratings have been established on these ratings. Natural gas ratings havebeen established on natural gas with net calorific value of approximately 36.8 mJ/m3(988 Btu/ft3).

PrimeThese ratings are applicable for supplying continuous electrical power (at variable load)in lieu of commercially purchased power. There is no limitation to the annual hours ofoperation and this model can supply 10 percent overload power for 1 hour in 12 hours.

OLYMPIAN DIESEL RATING DEFINITIONS:14

Page 9: Pocket Rating Guide Gensets_LEXE2576-07

60Hz OLYMPIAN (NORTH AMERICA) GAS RATINGS

*Ratings at 0.8 pf and 43°C (100°F)**Ratings at 1.0 pf and 32°C (90°F)

Standby ekW Prime ekWLP

1015

17.52025253035455575–

1215202025253040506080–––

Natural

1015

17.52025213035

42.55570100

1215202025253040456075100125150

LP

913.5

–18–

22.527

31.5405064–

1113.5

–18–

22.52736

42.55568–––

Natural

913–18–1827

31.536506085

1113.2

–18–212736

37.555

63.585114

134.4

Gen SetModel

G10U3SG15U3S

G17.5UH3SG20F3S

G25UH3SG25F3SG30F3SG35F3SG45F3SG55F3SG75F3SG100F3S

G12U3G15U3

G20UH3G20F3

G25UH3G25F3G30F3G40F3G50F3G60F3G80F3G100F3G125G1G150G1

Single Phase output**

3-Phase output*

rpm

180018003600180036001800180018001800180018001800

18001800360018001800180018001800180018001800180018001800

OLYMPIAN (INTERNATIONAL) 50Hz GAS RATINGSStandby ekW Prime ekW

LP

132024

16.52530

Natural

11.817.524

152230

LP

1117–

1422–

rpm

150015003000

150015003000

Natural

1014.8

12.519–

Gen SetModel

GEUG13S1GEFG20S1

GEUHG24S1

GEUG16-1GEFG25-1

GEUHG30-1

Single Phase output**

3-Phase output*

Standby ekW Prime ekWLP

162525

162525

Natural

152325

152525

LP

13.522–

13.522.5

rpm

180018003600

180018003600

Natural

1320–

13.521.2

Gen SetModel

GEUG13S1GEUFG20S1GEUHG24S1

GEUG16-1GEFG25-1

GEUHG30-1

Single Phase output**

3-Phase output*

OLYMPIAN (INTERNATIONAL) 60Hz GAS RATINGS

*Ratings at 0.8 pf and 43°C (100°F)**Ratings at 1.0 pf and 32°C (90°F)

1716

Page 10: Pocket Rating Guide Gensets_LEXE2576-07

CAT 50 Hz GAS RATINGS

kVA

1061381561561942002192312812883634064444506006389069561219128813561431138014562000200024382500

ekW

85110125125155160175185225230292325355360480510725766975103010901145110511651600160019502000

EngineModel

G3306G3306G3306G3406G3408G3406G3406G3406G3412G3408G3412G3412G3412

G3412CG3508G3508G3512G3512G3516G3516

G3516BG3516BG3516BG3516BG3516CG3516EG3520CG3520C

Continuous

1500 rpmNotes*

–31––331–1331331313131

5,35,11,31,31,3

1,3,5

*Notes: All ratings at 0.8 pf and without fan (G3406 NA includes fan and radiator).

1–32°C (90°F). 2–45°C (113°F). 3–54°C (130°F). 5–Ratings at 0.8 pf with fan.

CAT ENGINES & GENERATOR SETS(GAS)

19

Page 11: Pocket Rating Guide Gensets_LEXE2576-07

*Notes: All ratings at 0.8 pf and without fan (G3406 NA includes fan and radiator).

1–32°C (90°F). 3–54°C (130°F). 4–70°C (158°F). 5–Ratings at 0.8 pf with fan.

CAT 60 Hz GAS RATINGS

Continuous

100135150150190210225250255280350375375395425–

13001400166019002055

EngineModel

G3306G3306G3306G3406G3406G3406G3406G3412G3408G3408G3412

G3412CG3412G3412G3412G3516

G3516BG3516BG3516CG3520CG3520C

1800 rpmNotes*

–31–

3,531–31

3,53,53,531331343

ekWStandby

–––

150245260275–

310340350375450480–

1040–––––

Continuous

CAT 50 Hz GAS RATINGS (cont.)

ekW

1270135516951805257527252900342536303860

59001460

EngineModel

G3606G3606G3608G3608G3612G3612G3612G3616G3616G3616

G16CM34G3520B

1000 rpmNotes*

5,35,15,35,15,35,25,15,35,25,1

–5,1

750 rpm

kVA

1588169421192556321934063625428145384825

73751825

*Notes: All ratings at 0.8 pf and without fan (G3406 NA includes fan and radiator).

1–32°C (90°F). 2–45°C (113°F). 3–54°C (130°F). 5–Ratings at 0.8 pf with fan.

2120

Page 12: Pocket Rating Guide Gensets_LEXE2576-07

Standby These ratings are applicable for supplying continuous electrical power (at variable load)in the event of a utility power failure. No overload is permitted on these ratings. Naturalgas ratings have been established on natural gas with net calorific Low Heat Value (LHV)of approximately 35.6 mJ/m3 (905 Btu/ft3) and 80 methane number (MN).

ContinuousOutput available without varying load for an unlimited time. Continuous power inaccordance with ISO8528, AS2789,and BS5514. Natural gas ratings have been establishedon natural gas with net calorific Low Heat Value (LHV) of approximately 35.6 mJ/m3 (905Btu/ft3) and 80 methane number (MN).

TA — Turbocharged-AftercooledekW — Generator output at 0.8 pfkVA — Generator output

CAT GAS RATING DEFINITIONS:

EngineModel

G3512G3508G3508G3512G3512G3512G3512G3516G3516G3516G3516

G3520CG3520E

G3606G3606G3608G3608G3612G3612G3616G3616

G16CM34

Continuous

36537540055557057060075077077082016001600

11451220152516252335261531053408

5900

Notes*

–313311331133

5,35,15,35,15,35,15,35,1

CAT 60 Hz GAS RATINGS (cont.)

Standby

–––––––––––––

––––––––

900 rpm

1200 rpm

720 rpm

*Notes: All ratings at 0.8 pf and without fan (G3406 NA includes fan and radiator).

1–32°C (90°F). 3–54°C (130°F). 5–Ratings at 0.8 pf with fan.

ekW StandbyThese ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings.Natural gas ratings have been established on natural gas with net calorific value ofapproximately 36.8 mJ/m3 (988 Btu/ft3).

Prime These ratings are applicable for supplying continuous electrical power (at variable load)in lieu of commercially purchased power. There is no limitation to the annual hours ofoperation and this model can supply 10 percent overload power for 1 hour in 12 hours.

OLYMPIAN GAS RATING DEFINITIONS:2322

Page 13: Pocket Rating Guide Gensets_LEXE2576-07

Single-Phase

V x I x P.F.1000

V x I1000

KW .746 x EFF. (Gen)

HP x .746EFF. (Mot.)

HP x .746V x P.F. x EFF.

KW x 1000V x P.F.

KVA x 1000V

Poles x RPM120

V x I x 1-(P.F.)2

1000

100 (VNL-VFL)VFL

Three-Phase

1.732 x V x I x P.F.1000

1.732 x V x I1000

KW .746 x EFF. (Gen)

HP x .746EFF. (Mot.)

HPx .7461.732 x V x EFF. x P.F.

KW x 10001.732 x V x P.F.

KVA x 10001.732 x V

Poles x RPM120

1.732 x V x I x 1-(P.F.)2

1000

100 (VNL-VFL)VFL

ELECTRICAL TABLES

To Obtain

Kilowatts

KVA

Horsepower required when KWknown (Generator)

KW input when HP known (Motor)

Ampheres when HP known

Ampheres when KW known

Ampheres when KVA known

Frequency(c.p.s)

ReactivekVA (KVAR)

% VoltageRegulation

Direct Current

V x I1000

KW .746 x EFF. (Gen)

HP x .746EFF. (Mot.)

HP x .746V x EFF.

KW x 1000V

100 (VNL-VFL)VFL

24

Alternating Current

ELECTRICAL TABLE ABBREVIATIONS:

V - voltage in voltsI - current in ampheresKW - power in kilowatts (actual power)KVA - kilovolt-ampheres (apparent power)HP - horsepowerRPM - revolutions per minute

KVAR - reactive kilovolt-ampheresEFF. - efficiency as a decimal factorNL - no loadFL - full loadP.F. - power factorNote: DC KW = DC KVA

216 VOLTS

240 VOLTS

240 VOLTS

240 VOLTS2

216 VOLTS

216 VOLTS

2

THREE-PHASE, THREE-WIRE (WYE)B

THREE-PHASE, FOUR-WIRE (WYE)C

125 VOLTS

125 VOLTS

125 VOLTS

THREE-PHASE CONNECTION SYSTEMS25

240 VOLTS

240 VOLTS

230 VOLTS

230 VOLTS

2

240 VOLTS

2

230 VOLTS115 VOLTS

115 VOLTS

240 VOLTS

240 VOLTS

THREE-PHASE, THREE-WIRE (DELTA)B

THREE-PHASE, FOUR-WIRE (DELTA)D

Page 14: Pocket Rating Guide Gensets_LEXE2576-07

REDUCED VOLTAGE STARTERS

Type of Starter

Full Voltage Starter

Auto Transformer• 80% Tap• 65% Tap• 50% Tap

Resistor StarterSingle Step

(adjusted for motorvoltage to be 80%

of line voltage)

Reactor• 50% Tap• 45% Tap• 37.5% Tap

Part Winding (lowspeed motors only)

• 75% Winding• 80% Winding

Motor Voltage(% Line Voltage)

100

806550

80

5045

37.5

100100

Line Current (% Full Voltage)Starting Current

100

684630

80

5045

37.5

7550

Starting Torque(% of Full Voltage)

Starting Torque

100

644225

64

252014

7550

26

Characteristic

Starting Line Currentat Same Motor

Terminal Voltage

Starting PowerFactor

Power Draw fromLine during Starting

Torque

Smoothnessof Acceleration

Relative Cost

Ease of Control

Maintenance

Line Disturbance

Autotransformer

Least

Low

Low

Increases slightlywith speed

Motor momentarilydisconnected from

line from start to run

Average

Same

Same

Reactor

Low

Average

Same

Same

Two-Step Part Winding

Low

Increases slightlywith speed

Smooth

Less than others

No provision for adjustment ofstarting current

Less than others

More than others

––– More than autotransformer type –––

––– Varies with conditions and type of load –––

*Resistor starting adds considerable kW load to generator set. Total power required includes the motor kW and the kW which is lost as heat in the resistor.

The series resistors account for a higher than normal starting power factor.

COMPARISON OF REDUCED VOLTAGE STARTING METHODS

––– More than autotransformer type –––

Increases rapidly with speed

Smooth. Transfer made with little change in

motor terminal voltage

27

Primary Resistor

High*

Lower in small size-otherwise equal

Same

Same

Page 15: Pocket Rating Guide Gensets_LEXE2576-07

Engine room ventilation can be estimated by the following formulas,assuming 100°F (38°C) ambient air temperature:

V (cfm) = H + Engine Combustion Air0.070 x 0.24 x T

V (m3/min) = H + Engine Combustion Air1.099 x 0.017 x T

V = Ventilation air (cfm) (m3/min).H = Heat radiation (Btu/min) (kW).

T = Permissible temperature rise in engine room (°F) (°C).Density of air at 100°F = 0.070 lb/cu ft (1.099 kg/m3).Specific heat of air = 0.24 Btu/°F (0.017 kW/°C).

ENGINE ROOM VENTILATION28

Day Tank Sizing

Tank Size (gal) = Rated BSFC (lb/hp•hr) x Rated HP x Load Factor7.076 (lb/gal)

x Hours Between Refilling+ Reserve Requirement

ORRule of Thumb for tank size with 25% reserve0.056 x Ave. BHP demand x Hours between refills x 1.25 = gal.0.27 x Ave. BKW demand x Hours between refills x 1.25 = liters.

Note: Additional tank capacity required for cooling of recirculated fuel in unit injectedengines. Tank should be located below level of injectors or nozzles.

On-Site Power RequirementsBased on 100,000 sq ft. of office bldg., etc and 40°N. Latitudes

• Electric Requirements600 kW continuous load(Air conditioning is absorption)Use three - 300kW units(2 prime and 1 standby)

Refrigeration• One ton refrigeration = 200 Btu/min = 12,000 Btu/h• One Boiler hp = 33,475 Btu/h• One ton compressor rating = One engine hp• Auxilary air conditioning equipment requires 1/4 hp/ton of compressor rating

Ice Plant• Complete power requires 4-5 hp per daily ton capacity

Air Compressor• hp = 1/4 x cu ft m/min at 100 psi

Increase bhp 10% for 125 psiDecrease bhp 10% for 80 psi

FUEL SYSTEM - DIESEL

• Air Conditioning and Compressor400 tons prime loadUse two - 200 hp engines(No Standby)

29

Page 16: Pocket Rating Guide Gensets_LEXE2576-07

Unit1 Kilogram

1 Ounce1 Pound

1 Short Ton1 Long Ton

1 Metric Ton

Kilograms1

0.028350.4536907.21,0161,000

OuncesAvoirdupois

35.27116

32,00035,84035,300

PoundsAvoirdupois

2.2050.0625

12,0002,2402,205

Short–––1

1.121.102

Long–––

0.89291

0.9842

Metric–––

0.90721.016

1

Unitmm2

in2

m2

ft2

mm2

1645.16

10 0000092903

in2

0.001551

1550144

m2

–0.000 645 16

10.0929

ft2

–0.006 944

10.7641

Area

CONVERSION FACTORS

mm1

25.4304.8914.41000

100 0000160 9340

in.03937

11236

39.370139 370.163 360

ft.0032810.083 33

13

3.280 843208.84

5280

yd.0010940.027 780.333 33

11.093 611093.61

1760

m.001

0.02540.30480.9144

11000

1609.34

km.0000 010.000 030.000 300.000 91

0.0011

1.609 34

mi––––

0.000 620.621 37

1

1 sq mile = 640 acres1 acre = 4840 yd2

1 cir mil = 7.854 x 10-7in2

1 cir mil = .7854 x mils21 cir mil = 5.067 x 10-6cm2

LengthUnitmminftydm

kmmi

1 grain = 0.064799 gram

30

––– Tons –––

Weight

U.S. gal/min

1694.5448.84.40315.85

million U.S.gal/day

0.001 4401

0.6460.006 340.0228

ft3/s0.002 23

1.5471

0.009 810.0353

m3/h0.2270157.73101.9

13.60

L/s0.063143.828.320.2778

1

Flow

UnitU.S. gpm

1 million gal/dayft3/sm3/hL/s

BTUCalorie

Foot-PoundJoule

KilocalorieTherm

Btu1

0.003970.0012850.0009483.96825100,000

Cal2521

0.3237650.23895

1000396.8254

ft-lb778

3.088661

0.737453089

128.5347

J1055.056

4.1871.356

14185.0

94.78169

Kcal0.2520.001

0.0030890.000239

10.39682

Therm0.000010.0025190.0008160.010552.519

1

1 Therm = 1,000,000 BtuBtu/ft2/min = 0.1220 Watts/in2

Btu/ft3 = 8.899 kg-cal/m3

Btu/lb = .5556 kg-cal/kg

Energy

MCFD = 1000 ft3/day MMCFD = 1,000,000 ft3/day lb/bhp-hr x 607.73 = g/kW-hr

31

Page 17: Pocket Rating Guide Gensets_LEXE2576-07

CONVERSION FACTORS (cont.)

Unitmm/Hgin./Hgin. H20ft. H20lb/in2

kg/cm2

barkPa

mm/Hg(0°C)

125.4

1.868 2722.419251.7149735.559750.0627.500 62

in./Hg(0°C)

0.039 371

0.07 3550.882 652.036 0228.95929.530

0.295 30

in. H20(60°F)0.535713.61

112

27.70394.7401.8

4.01835

ft. H20(60°F)

0.044641.134

0.083 331

2.30932.8433.49

0.33486

J/min1055.0001.350444791

14412759997

59.9968

Metric hp0.023910.000031.014

0.00002261

1.359620.00136

kW0.01758430.00002260.74570

0.00001660.73549

10.001

W17.58430.0226745.7

0.016668735.498

10001

Power

Unitin3

ft3

yd3

mm3

m3

U.S.gallmp gal

literacre-ft

in3

1172846656

6.1 x 10-5

61 023.7231

277.41961.023 7

ft3

0.000 58127

4.0 x 10-8

35.31470.133 680.160 540.035 3143 560

yd3

0.000 020.037 04

1-

1.307 950.004 950.005 950.001 311613.33

mm3

16387.128 320 000764 554 858

11,000,000,000

378542045400901000 000

m3

0.000 020.028 320.76455

-1

0.003 780.004 55

0.0011233.48

U.S. gal0.004 327.480 52201.974

2.6 x 10-7

264.1921

1.200 950.264 17325 851

lmp gal0.003 615.228 83168.178

2.2 x 10-7

219.9690.832 67

10.219 97271 335

liter0.0163928.3169764.555

1.0 x 10-6

10003.785 414.546 09

1–

1 board-foot = 144 in3 1 bushel = 1.244 ft3 1 bushel = 4 pecks

Volume and CapacityVolume and Capacity

Pressure and Head

32

Btu/minft-lb/min

HorsepowerJoules/minMetric hpKilowatt

Watt

Btu/min1

0.0012842.4560.0009541.82756.86900.05687

ft-lb/min778.2

1330000.7405325504425044.25

hp0.023580.00003

10.00002230.986321.341020.00134

33

lb/in2

0.019 340.491 150.036 130.433 52

114.225714.504

0.145 038

kg/cm2

0.001 360.034 530.002 540.030 4790.070 31

11.019 72

0.010 1972

bar0.001 330.033 860.002 490.029 890.068 950.980 67

10.010 000

Atmospheres101.4kPa (14.7 psi)

0.001 3150.033 420.002 460.029 500.068 050.967 840.98692

0.009 869 20

kPa––

0.2492.9896.89598.067101.325

1

Page 18: Pocket Rating Guide Gensets_LEXE2576-07

NEMA Code Letter

ABCDEFGHJKLMNPRSTUV

Starting skVA/hp

0.00 - 3.143.15 - 3.543.55 - 3.994.00 - 4.494.50 - 4.995.00 - 5.595.60 - 6.296.30 - 7.097.10 - 7.998.00 - 8.999.00 - 9.99

10.00 - 11.1911.20 - 12.4912.50 - 13.9914.00 - 15.9916.00 - 17.9918.00 - 19.9920.00 - 22.39

22.40

Identifying Code Letters on AC Motors

Note: Code letters apply to motors up to 200 HP.

Temperature Conversion°F = (1.8 x °C) + 32

°C = 0.5555 (°F - 32)

34 35

Page 19: Pocket Rating Guide Gensets_LEXE2576-07

Asia and Pacific:SingaporeTel: ++65 6828 7118Fax:++65 6828 7414

ChinaBeijing OfficeTel: ++86 10 5921 0339Fax: ++86 10 5921 0022

TokyoTel: ++81 3 5786 3800 – 81 3 5797 4300Fax: ++81 3 5786 3809 – 81 3 5797 4359

Euope, Africa, Middle East:Geneva, SwitzerlandTel: +41 22 849 4444Fax: +41 22 849 4139

Commonwealth of Independent StatesMoscow, RussiaTel: +7 495 755 6811Fax: +7 495 785 5688

North America (Canada and U.S.A.):Peoria, IL U.S.A.Tel: ++1 309 578 6298Fax: ++1 309 578 2559

Central and South America, Mexico, The Caribbean:Miami, Florida, U.S.A.Tel: ++305 476 6800Fax: ++305 476 6850

(Listing does not include all Caterpillar offices.)

Email: [email protected]

LEXE2576-07© 2006 Caterpillar All Rights Reserved CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow” and the POWER EDGE trade dress,

as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.

If you have any questions, please consult your local Caterpillar dealer. If you need assistance in finding a dealer, consult one of our Caterpillar offices.

CATERPILLAR OFFICES