24
Systems Integration Specialists Company, Inc. The Standards Based Integration Company © Copyright 2011 SISCO, Inc. CIM Base PMU Registry John Gillerman SISCO, Inc. Tel: +1-732-937-9745 Mobile: +1-732-979-9595 Email: [email protected]

Pmu Registry Sisco - Naspia

Embed Size (px)

Citation preview

Page 1: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 1/24

Systems Integration Specialists Company, Inc.

The Standards Based Integration Company

© Copyright 2011 SISCO, Inc.

CIM Base PMU Registry

John GillermanSISCO, Inc.Tel: +1-732-937-9745Mobile: +1-732-979-9595Email: [email protected]

Page 2: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 2/24

© Copyright 2011 SISCO, Inc.2

Demo Components

IEC 61850

L3-IP GOOSE

Converter 

GOOSE IP

Multicast

GOOSE L3

Multicast

Substation LAN

Control Center LAN

SISCO/OSIsoft

UAP with High

Speed Phasor Analytics

And Registry Consumer 

GOOSE L3Multicast

IEC 61850

L3-IP GOOSE

Converter 

GOOSE L3Multicast

GOOSE IPMulticast

OSIsoft PI

GOOSE L3Multicast

C37.118 IPMulticast

Cisco PMOD

IP Multicaster 

C37.118 IP

Multicast

C37.118.1

Unicast from SEL

487s

These WAN

routing functions

actually supplied

by a singe router for the demo

SISCO/OSIsoft

UAP Phasor 

Gateway with

CIM Based Registry

Simulated C37.118

GOOSE L3

Multicast

IEC 61850

L3-IP GOOSE

Converter 

GOOSE IP

Multicast

GE N60

GOOSE L3

Multicast

EPRI Knoxville

and Lenox Labs

GE N60

GOOSE L3

Multicast

Voltage and

currents

Voltage and

currents

C37.118 IP

Multicast

Instep

GOOSE L3Multicast

GE UR+

C37.118 IPMulticast

Instep

OPC UA Web

Services

OPC UA WebServices

Verizon WAN (MPLS Network)

Page 3: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 3/24

© Copyright 2011 SISCO, Inc.3

Topics

SISCO

NASPInet

IEC Common Information Model

Registry Use

Page 4: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 4/24

© Copyright 2011 SISCO, Inc.4

SISCO Active in Standards

ISO TC184 - ISO 9506 (MMS)

EPRI UCA 2.0 (IEEE TR1550)

Control Center API (Common Information Model – CIM)

IEC Technical Committee 57 (TC57) WG07 – IEC60870-6 TASE.2 (ICCP)

WG10 – IEC61850 WG13 – IEC61970 (CIM and API)

WG14 – IEC61968 (CIM)

WG15 – Communications Security

WG16 – Energy Market Extensions to CIM

WG17 – Distributed Resources WG19 – TC57 Harmonization

OPC Foundation Unified Architecture

Page 5: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 5/24

© Copyright 2011 SISCO, Inc.5

ICCP

SISCO Products: where they fit

Distribution

ManagementSystems (DMS)

IT-Systems

Utility Control Center 

External Control Center or 

Independent System Operator 

Remote

Terminal Unit(RTU)

Substation/Field Device Substation/Field Device

Substation

AutomationSystem

Energy

ManagementSystems (EMS)

Utility Integration Bus (UIB) – CIM/API

Power Plants

SubstationAutomation

System

IEC 61850

Control Center 

Integration

Products

IEC 61850Communication

Products

Intercontrol

Control Center 

Communication

Products

Switchgear , Transformers,Instrumental Transformers

Supervisory Control and

Data Acquisition

(SCADA)

Inter-Control Center Data link

Page 6: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 6/24

© Copyright 2011 SISCO, Inc.6

SISCO Products - Communications

IEC61850 Substation Automation Protocol source code for OEMs: MMS-EASE Lite

AX-S4 MMS (“Access for MMS”) OPC interface for plug-in access to

IEC61850 for Windows applications.

Unified Analytic Platform for real-time analytics using IEC GOOSE

ICCP-TASE.2 for Intercontrol center communications and power plant

dispatching:

ICCP Development Tools: for OEMs to embed ICCP into their applications

and devices

ICCP-TASE.2 Extensions for MMS-EASE Lite (Source Code) ICCP Toolkit for MMS-EASE (Binary Object Library)

AX-S4 ICCP (“Access For ICCP”) OPC interface for plug-in access to ICCP

for Windows applications

Page 7: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 7/24

© Copyright 2011 SISCO, Inc.7

SISCO Products - Integration

Utility Integration Bus (UIB) Electric utility specific standards based extensions for off-the-shelf commercial

middleware

Provides IEC T57 and IntelliGrid standard support enabling extension of EAI,

BPI, BPM, and Enterprise Information Integration (EII) into the operations

functions of utilities. IBM WebSphere

Other JMS based middleware can be supported

Products

Development tools enabling standards based application adapter 

development Deployment tools for off-the-shelf integration:

Adapters

Page 8: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 8/24

© Copyright 2011 SISCO, Inc.8

SISCO Products for the OSIsoft PI System

AX-S4 ICCP

Preferred OSIsoft interface for ICCP-TASE.2

AX-S4 MMS

Preferred OSIsoft Interface for IEC 61850

COMTRADE Utility

Retrieves IEEE COMTRADE format disturbance and oscillography files from substationdevices and stores them into the PI archive

UIB Adapter for PI

Empowers the PI environment with support for the Common Information Model (CIM),the standard API/Services, and SOA middleware.

Unified Analytic Platform for PI

Real-time analytic platform for wide are remedial action using IEC 61850 GOOSE, PMU data,and other real-time streams on the OSIsoft PI System.

Page 9: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 9/24

© Copyright 2011 SISCO, Inc.9

Some SISCO Customers

San Diego Gas & Electric

Southern California Edison Sacramento Municipal Utility District

US Army Corps of Engineers

TXU Energy Delivery

DTE Energy

Long Island Power Authority

Xcel Energy American Electric Power 

Tennessee Valley Authority

Centerpoint Energy

EDF

Shanghai Municipal Power Authority

Korean Electric Power Company

ETSA Utilities

General Motors

Boeing

US Postal Service

ABB

AREVA T&D General Electric

Siemens

Intergraph

Power Costs

OSIsoft

Dranetz/BMI Telvent

LS Industrial Systems

Toshiba

Schweitzer Engineering Labs

Reinhausen

Shandong Luneng

Sifang Automation

Doble Engineering

XJ Electric

many resellers and integrators

End Users OEMs

Page 10: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 10/24

© Copyright 2011 SISCO, Inc.10

NASPI Architecture

Use IEC 61850 90-5/C37.118 multicast for 

current phasor data .

Use OPC API to isolate applications fromthe particulars of the NASPInet databaseprotocols and services. (PDC’s andarchive require native 90-5 and C37.118

support)

Use IEC 61970 OPC UA Web Services for historical phasor data as well as registrydata, alarms, network model data and for NASPInet Data Bus Configuration.

Expose merged phasor registry data witha CIM topology model.

Real-time Historical

EC

Real-time Historical

Phasor 

Gateway

NASPInet Data Bus

PDC

Page 11: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 11/24

© Copyright 2011 SISCO, Inc.11

Current PMU Data Within The Context Of A CIM View

View changes with

model changes Access by Navigation

Phasor Gateway

Client

PMU Registry

TVA Phasor 

Gateway

PMU 1 PMU 2 PMU 3 PMU 4

Phasor 

Set 1

High QoS

Phasor 

Set 1

Low QoS

Phasor 

Set 2

High QoS

Phasor 

Set 2

Low QoS

Phasor 

Set 3

High QoS

Phasor 

Set 3

Low QoS

Phasor 

Set 4

High QoS

Phasor 

Set 4

Low QoS

Entergy Phasor 

Gateway

NASPInet DataBus

Page 12: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 12/24

© Copyright 2011 SISCO, Inc.12

PMU Registry Data Within The Context Of A CIM View

View changes with

model changes Access by Navigation

Phasor Gateway

Client

PMU Registry

TVA Phasor 

Gateway

PMU 1 PMU 2 PMU 3 PMU 4

Entergy Phasor 

Gateway

NASPInet DataBus

PMU

Make/

Model

PMU

Install Date

PMU

Make/

Model

PMU

Install Date

PMU Registry

data exposed

as additional

attributes inthe CIM

based tree PMU

Make/

Model

PMU

Install Date

PMU

Make/

Model

PMU

Install Date

Page 13: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 13/24

© Copyright 2011 SISCO, Inc.13

Example Based Phasor Gateway/PDC/Archive Architecture

Optional

Standard

OPC

Interface

PMU registry data as well

as current and historical

phasor data

Current phasor 

data

Open PDC

PMU Registry

DB

Phasor Data

Cache/

Archivie

C37.118

Interface

OPC UA Secure,

Cross Platform

Web Services

Current phasor 

data

IEC 61850

90-5

Interface

CIM XML file

CIM

Topology

View

Data

References

EMS

Page 14: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 14/24

Page 15: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 15/24

© Copyright 2011 SISCO, Inc.15

Common Information Model (CIM) is an object-orientedinformation model of the power system

Central GeneratingStation

Step-UpTransformer 

Distribution

Substation

Receiving

Station

Distribution

Substation

DistributionSubstation

Commercial

Industrial Commercial

GasTurbine

RecipEngine

Cogeneration

RecipEngine

Fuelcell

Micro-turbine

Flywheel

Residential

Photovoltaics

Batteries

UML – Unified Modeling Language

Page 16: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 16/24

© Copyright 2011 SISCO, Inc.16

Benefits of Models

Models give context and meaning to data improving

integration and interoperability.

The information contained in the model enables

automation of setup and maintenance tasks.

Model aware applications can be made independent of the data.

Page 17: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 17/24

© Copyright 2011 SISCO, Inc.17

Legacy Data Model – Data is Referenced by TagSCADA

I need the primary current

of the 345KV transformer 

in the airport substation

Page 18: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 18/24

© Copyright 2011 SISCO, Inc.18

How do users find this today?

With lots of paper 

documentation and manual

maintenance effort subject

to manual error detectionand correction.

Page 19: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 19/24

© Copyright 2011 SISCO, Inc.19

SISCO UIB Adapter for PI

Brings power system models to the OSIsoft PI archive system

Allows PI data to be viewed in the context of the power system model

within the PI application environment

Supports the EPRI CIM model or any user specific model via XML

Includes OPC Server and Client Adapters:

PI access to any UIB data source

UIB clients can access PI data

Can be used with or without UIB for external applications

Page 20: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 20/24

© Copyright 2011 SISCO, Inc.20

Tag Based Access

What tags belong to

which equipment?PI

Telemetry

PI Tags

??

Server 

Historized

Values

Page 21: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 21/24

© Copyright 2011 SISCO, Inc.21

CIM Based Data Access

Data Relationships

are now visible

Telemetry

PI

DATAArchive

Historized

Models andValues

MODELSMDB

or AF

Page 22: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 22/24

© Copyright 2011 SISCO, Inc.22

UIB Adapter Application

PI ProcessBook

UIB Adapter for PI

PI

External

Model

RepositoryModel Population and Synchronization

SISCO

Control

Other CIMApplications

CIM

Model/Schema

Definitions

XML

CIM Model

Instance

Information

PI Interface

Standard Interface

SISCO UIBSISCO UIB

MDB

or 

AF

Archive

X

CIM

XML

ModelsData

Model-Driven

Application Access

Page 23: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 23/24

© Copyright 2011 SISCO, Inc.23

Node record from the OpenPDC PMU Registry DB

Device record from the OpenPDC PMU Registry DB

CIM data from a

CIM XML file

CIM Measurement Value containing

current and historical phasor data.

CIM Based PMU Registry in PI AF

Page 24: Pmu Registry Sisco - Naspia

8/6/2019 Pmu Registry Sisco - Naspia

http://slidepdf.com/reader/full/pmu-registry-sisco-naspia 24/24

Systems Integration Specialists Company, Inc.

The Standards Based Integration Company

© Copyright 2011 SISCO, Inc.

Thank You

John GillermanSISCO, Inc.Tel: +1-732-937-9745Mobile: +1-732-979-9595Email: [email protected]