18
PMT Readout and Floor Triggering PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis George Bourlis

PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Embed Size (px)

Citation preview

Page 1: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

PMT Readout and Floor TriggeringPMT Readout and Floor Triggering• Charge estimation using the times over the thresholds• Event Building and Triggering

+

multiplicity

George BourlisGeorge Bourlis

Page 2: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

ReadOut Electronics

GPS Input

USB PortTrigger Output5 PMT Signal Inputs

25ps accuracy TDC

HPTDC

• 32 channels (LR) – 8 Channels (HR)

•25ps (HR) to 100 ps (LR) accuracy

•Self Calibrating

Page 3: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

ReadOut Electronics

Page 4: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

EZ-USB FX2 HPTDC CONTROL

Page 5: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis
Page 6: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Card Debugging Configuration

Trigger

Input

splitter

splitter

discriminator

- Offset of each input

- Scale of each input

- Timing among input channels

Page 7: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Sample PulsesInput 1

Page 8: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Sample PulsesInput 1

Page 9: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Sample PulsesInput 1

Page 10: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

The Photomultiplier Tube:

PH: XP1912

Charge (pCb)

Single p.e

Gain vs HV

Calibration

@ “nominal” H.V.

gain: ~ 4 105

<charge>/p.e. ~ 0.07pCb

<pulse height>/p.e. ~ 1.05mV

Rise Time: 1.2 ns

Charge (in units of mean p.e. charge)

At the Detector Center

Data

- Monte Carlo Prediction

Page 11: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Charge versus Time Over ThresholdC

ha

rge

(p

C)

Time Over Threshold (s)

1st Threshold only 1st & 2nd Threshold 1st, 2nd & 3rd Threshold

4mV

50mV

15mV

Page 12: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Charge Parameterization

1st & 2nd Threshold 1st, 2nd & 3rd Threshold

kkCharge= a (tot)

Page 13: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Charge Estimation

1st & 2nd Threshold 1st, 2nd & 3rd Threshold

Measured Charge - Estimated Charge

Measured Charge

11% 8%

- Estimated Resolution ~10%

- Better if all thresholds are crossed

Page 14: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Charge Estimation

1st & 2nd Threshold 1st, 2nd & 3rd Threshold

Measured Charge - Estimated Charge

Estimated Error

- σ=(1.01 ± 0.01) (2 thresholds)

- σ=(1.1 ± 0.1) (3 thresholds)

Page 15: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis

Time (ns)

Trigger

Input

Page 16: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis
Page 17: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis
Page 18: PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis