PLUMBING
COVER SHEET
P0-01
P0-01 PLUMBING COVER SHEET
PLUMBING SHEET INDEX
ISSUE LOG
TITLE#
DATE
P1-01 PLUMBING - WASTE & VENT - 1ST FLOOR
P1-02 PLUMBING - WASTE & VENT - 2ND & 3RD FLOOR
P1-03 PLUMBING - WASTE & VENT - 4TH & ROOF FLOOR
P2-01 PLUMBING - DOMESTIC & GAS - 1ST FLOOR
P2-02 PLUMBING - DOMESTIC & GAS - 2ND & 3RD FLOOR
P2-03 PLUMBING - DOMESTIC & GAS - 4TH FLOOR & ROOF
P3-01 PLUMBING - LARGE SCALE ROOM PLANS
P4-01 PLUMBING - RISER DIAGRAM
P5-00 PLUMBING - SCHEDULES
P6-00 PLUMBING - DETAILS
P6-01 PLUMBING - DETAILS
P6-02 PLUMBING - DETAILS
P4-00 PLUMBING - RISER DIAGRAM
NATURAL GAS LOAD
FIXTURE
INPUT (MBH)
INLET PRESSURE
MIN-MAX (in WC)
DRYER
135 3.5" WC - 7.0" WC
DRYER
135 3.5" WC - 7.0" WC
DRYER
135 3.5" WC - 7.0" WC
WH-1
751 8" WC
WH-2
751 8" WC
WH-3
251 8" WC
MAU-1
150 4.0" WC - 14.0" WC
MAU-2
300 4.0" WC - 14.0" WC
TOTAL CONNECTED LOAD (MBH) 2608.00
NOTES:
1. GAS METER, REGULATOR, AND GAS COCK PROVIDED BY UTILITY COMPANY.
COORDINATE EXACT LOCATION OF METER SET WITH UTILITY COMPANY.
2. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON FITTINGS.
WHERE GAS PIPING CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG
THE FULL SIZE OF THE SUPPLY PIPE, A 100% SHUT-OFF GAS COCK AND UNION.
3. PORTIONS OF A GAS PIPING SYSTEM INSTALLED IN CONCEALED LOCATIONS SHALL NOT
HAVE UNIONS, TUBE FITTINGS OR RUNNING THREADS.
4. GAS PIPING SIZED PER FBC-FG 5th ed. TABLE 402.4(5). PIPE SIZING FOR 2 POUNDS
PRESSURE CAPACITY OF PIPES FOR AN INITIAL PRESSURE OF 2.0 psi WITH A 1.0 psi
PRESSURE DROP AND A GAS OF 0.6 SPECIFIC GRAVITY. TOTAL EQUIVALENT LENGTH: 275
FT. PROVIDE "LBS-TO-INCHES" REGULATORS AT EQUIPMENT CONNECTIONS AS REQ'D.
VENT ALL REGULATORS TO ATMOSPHERE.
PLUMBING GENERAL NOTES
REDUCED PRESSURE BACKFLOW PREVENTER
TEMPERATURE & PRESSURE RELIEF VALVE
VACUUM RELIEF VALVE
T & P
WATER HAMMER ARRESTOR
AUTOMATIC TRAP PRIMER
WHA
TP
WATERTIGHT SLEEVEWTS
UNION
ARROW INDICATES DIRECTION OF FLOW
G
CHECK VALVE
WASTE & TRAPW & T
CV
SHUT-OFF VALVE
NATURAL GAS
SOV
G
SANITARY WASTE
STORM/OVERFLOW
V
SD
VENT
SAN
COLD WATER
HOT WATERHW
CW
PRESSURE REDUCING VALVEPRV
SANITARY WASTE BELOW FLOOR
HOT WATER RECIRC
SAN
HWR
VTR
CLEANOUT PLUG FLUSH WITH FLOORCO
CLEANOUT PLUG OR WALL CLEAN OUTCO & WCO
FPHB & HBFREEZE PROOF HOSE BIBB WITH SOV INLINE
BFP
T
P
PRESSURE GAUGE WITH ISOLATION VALVEPG
PRESSURE GAUGE WITH ISOLATION VALVETG
CONCENTRIC VENT KIT
CVK
MIXING VALVEMV
RECIRCULATION PUMP
RCP
VENT THROUGH ROOF
-
-
VRV
PLUMBING LEGEND
POINT OF CONNECTION
POC
CIRCUIT SETTERCS
GMGAS METER
MEDICAL AIR
MEDICAL OXYGEN
MEDICAL VACUUMV
O
A
CONDENSATE DRAINCD
V
O
A
CD
GENERAL PLUMBING NOTES:
1. CODES AND PERMITS: ALL WORK TO BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL AND STATE CODES.
PERMIT AND CONNECTION FEES TO BE PAID BY CONTRACTORS AS REQUIRED. WARRANTY: WORK AND
MATERIALS TO BE WARRANTED FOR ONE (1) YEAR AFTER PROJECT COMPLETION.
2. THE CONTRACTOR SHALL FURNISH ALL LABOR, INSTALL ALL MATERIAL AND EQUIPMENT AND INCLUDE SERVICES
AND INCIDENTALS TO THE INSTALLATION OF WORK INVOLVED FOR A COMPLETE AND OPERATING FACILITY.
3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL REQUIRED PERMITS, INSPECTIONS, AND
PAY ALL FEES REQUIRED FOR THIS JOB.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSEMBLING ANY EQUIPMENT SHIPPED IN SECTIONS, IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
5. EACH EQUIPMENT CONNECTION TO HAVE SHUT-OFF COCK, DRIP LEG, AND UNION. WHERE DISTRIBUTION
PRESSURE IS HIGHER THAN UTILIZATION PRESSURE, PROVIDE SUITABLE PRESSURE REGULATOR.
6. PLUMBING FIXTURES, TRIM, AND ACCESSORIES: PROVIDE FIXTURES, TRIM, CARRIERS AND ACCESSORIES AS
SCHEDULED AND REQUIRED FOR COMPLETE INSTALLATION AND PROPER OPERATION. NO "ALTERNATES" OR
"EQUALS" MAY BE USED WITHOUT THE WRITTEN PRE-AUTHORIZATION BY THE ARCHITECT OR ENGINEER.
7. FAUCETS FOR LAVATORIES AND SINKS TO HAVE WASHERLESS CARTRIDGES WITH POSITIVE POSITIONING
SHUTOFF AGAINST METALLIC OR CERAMIC STOPS.
8. HANDICAPPED PROVISIONS: HEIGHTS OF FIXTURES DESIGNATED FOR HANDICAPPED USE SHALL BE IN
ACCORDANCE WITH ANSI A117.1-80, ADA, OR LOCALLY APPLICABLE HANDICAP CODES.
9. OFFSET P-TRAPS TO MAXIMIZE KNEE SPACE AT SINKS AND LAVATORIES. INSULATE EXPOSED WATER AND WASTE
PIPING WITH PREFABRICATED INSULATING ASSEMBLY.
10. FLUSH OPERATOR DEVICE FOR WATER CLOSETS TO BE LOCATED ON SIDE OF FIXTURE WITH WIDE DIMENSION IN
TOILET STALL OR ENCLOSURE.
11. THE PLUMBING DRAWINGS ARE DIAGRAMMATIC AND SHOW ONLY THE RELATIONSHIP BETWEEN EQUIPMENT AND
CONNECTION. DO NOT SCALE THE DRAWINGS FOR EXACT SIZES OR LOCATIONS. FIELD VERIFY ALL DIMENSIONS
PRIOR TO INSTALLATION OR FABRICATION.
12. AS PART OF THE PROJECT CLOSEOUT THE PLUMBING CONTRACTOR SHALL PROVIDE FULL PLUMBING SYSTEM
AS-BUILTS AS WELL AS TEST AND BALANCE REPORTS OF ALL PERTINENT SYSTEMS.
13. INSTALL PIPING TIGHT TO BEAMS, JOISTS, COLUMNS, WALLS AND OTHER PERMANENT ELEMENTS OF THE
BUILDING. PROVIDE SPACE TO PERMIT INSULATION APPLICATIONS WITH 1" CLEARANCE OUTSIDE THE
INSULATION. ALLOW SUFFICIENT SPACE ABOVE REMOVABLE CEILING PANELS TO ALLOW REMOVAL.
14. REFER TO PLUMBING FIXTURE SCHEDULE FOR WATER, WASTE AND VENT CONNECTION SIZES.
15. PROVIDE AUTOMATIC TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS, WHICH ARE LOCATED IN
INTERIOR SPACES. PRIMERS TO BE INSTALLED IN CW PIPING AT NEAREST SUITABLE FIXTURE, PREFERABLY A
LAVATORY. TRAPS TO HAVE FACTORY FABRICATED FITTING TO RECEIVE PRIMER LINE. PRIMERS TO HAVE
AUTOMATIC OPERATION, WITH BRONZE BODY, INTEGRAL VACUUM BREAKER, NON- LIMING INTERNAL
OPERATING ASSEMBLY, GASKETED BRONZE COVER, AND 1/2" CONNECTIONS. PRIMERS TO BE ZURN Z1022 OR
EQUAL.
16. PROVIDE SLEEVES FOR PIPES THRU FLOORS, MASONRY WALLS & FIRE OR SMOKE PARTITIONS. PENETRATIONS
THROUGH WALLS AND FLOORS BELOW GRADE AND OUTSIDE WALLS SHALL BE SEALED AND CAULKED WATER,
MOISTURE AND AIR TIGHT TO ARCHITECT APPROVAL.
ABBREVIATIONS
CO CLEAN OUT
CD CONDENSATE DRAIN
CW DOMESTIC COLD WATER
DF DRINKING FOUNTAIN
ECO EXTERIOR CLEANOUT
EEW EMERGENCY EYE WASH
EWC ELECTRIC WATER COOLER
EX EXISTING
FD FLOOR DRAIN
FPHB FREEZE PROOF HOSE BIB
FS FLOOR SINK
G GAS
GI GREASE INTERCEPTOR
GM GAS METER
GW GREASE WASTE
HB HOSE BIB
HW DOMESTIC HOT WATER
HWR DOMESTIC HOT WATER RECIRC
IWH INSTANT. WATER HEATER
LAV LAVATORY
MS MOP SINK
RD ROOF DRAIN
SH SHOWER
SK SINK
TUB BATHTUB
UR URINAL
VTR VENT THRU ROOF
WC WATER CLOSET
WCO WALL CLEAN OUT
WH WATER HEATER
WHA WATER HAMMER ARRESTOR
SD
P6-03 PLUMBING - DETAILS
P4-02 PLUMBING - RISER DIAGRAM
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
1
0
0
%
C
D
S
E
T
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
5/11/17
x
SANITARY SEWER FIXTURE LOAD
FIXTURE OCCUPANCY
TYPE OF SUPPLY
CONTROL
DRAINAGE FIXTURE UNIT
VALUES
QTY
TOTAL DFU'S
BATHROOM GROUPS PRIVATE FLUSH TANK 5.00 90 450.00
WATER CLOSET PUBLIC FLUSH VALVE 4.00 2 8.00
LAVATORY PUBLIC FAUCET 1.00 2 2.00
KITCHEN SINK PRIVATE FAUCET 2.00 2 4.00
3" FLOOR DRAIN PRIVATE - 5.00 2 10.00
MOP SINK PUBLIC FAUCET 2.00 1 2.00
DRINKING FOUNTAIN PUBLIC
3/8" VALVE
0.50 1 0.50
WASHING MACHINE PUBLIC WALL BOX 2.00 2 4.00
ADDED DRAINAGE FIXTURE UNIT TOTAL 480.50
DOMESTIC WATER FIXTURE LOAD
FIXTURE OCCUPANCY
TYPE OF SUPPLY
CONTROL
SUPPLY FIXTURE UNIT VALUES
QTY
TOTAL WATER
SUPPLY FIXTURE
UNITS
COLD HOT TOTAL
BATHROOM GROUPS PRIVATE - 2.70 1.50 3.60 90
324.00
WATER CLOSET PUBLIC FLUSH VALVE 10.00 0.00 10.00 2
20.00
LAVATORY PUBLIC FAUCET 1.50 1.50 2.00 2
4.00
KITCHEN SINK PRIVATE FAUCET 1.00 1.00 1.40 2
2.80
MOP SINK PRIVATE FAUCET 2.25 2.25 3.00 1
3.00
DRINKING FOUNTAIN PUBLIC
3/8" VALVE
0.25 0.00 0.25 1
0.25
WASHING MACHINE PUBLIC WALL BOX 2.25 2.25 3.00 2
6.00
ADDED WATER SUPPLY FIXTURE UNIT TOTAL
360.05
GPM
97
DOMESTIC WATER:
1. BACK FLOW PREVENTER AT THE BUILDING SERVICE ENTRY SHALL BE LOCAL AUTHORITY APPROVED TYPED
IRRESPECTIVE OF WHAT IS SHOWN ON THE DRAWINGS. THE REQUIRED TYPE SHALL BE VERIFIED PRIOR TO BID.
INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS WITH RECOMMENDED
CLEARANCES FOR TESTING AND SERVICE. BACK FLOW PREVENTER SHALL BE LOCATED IN ACCORDANCE WITH
STATE CODES, LOCAL CODES AND AUTHORITY HAVING JURISDICTION.
2. ALL COLD WATER SUPPLY LINES TO HAVE IN-LINE SHUT-OFF VALVES AT CONNECTION POINT TO MAIN. ALL
BRANCH DOMESTIC WATER PIPING TO PLUMBING FIXTURES TO HAVE IN-LINE SHUT-OFF VALVES. LOCATE
SHUT-OFF VALVES WITHIN EASY REACH ABOVE SUSPENDED CEILINGS. SEE ARCH REFLECTED CEILING PLAN.
3. INTERIOR ABOVE SLAB - TYPE L HARD-DRAWN COPPER WITH SOLDERED JOINTS.
4. INTERIOR BELOW SLAB - TYPE L SOFT-DRAWN COPPER WITHOUT JOINTS IN SIZES 1-1/4" AND SMALLER, AND
SILVER- BRAZED JOINTS IN SIZES 1-1/2" AND LARGER.
5. EXTERIOR BURIED PIPING - TYPE L HARD-DRAWN COPPER WITH SOLDERED JOINTS, OR LOCAL CODES
PERMITTING, POLYPROPYLENE (PP-R) SDR-11 'GREENPIPE' WITH FUSION WELDED JOINTS. INSTALL #10 AWG
COPPER TRACER WIRE WITH PLASTIC PIPING AND TERMINATE ABOVE GRADE AT BUILDING.
6. INSULATION: INSULATE DOMESTIC WATER LINES ABOVE GRADE WITH CLOSED CELL ELASTOMETRIC INSULATION.
THICKNESS AS FOLLOWS: 1/2" AT CW LINES AND 1" AT HW.
7. IF DOMESTIC WATER PIPING MATERIAL USED IS PEX-A ALL SIZES INDICATED ARE TO BE INCREASED BY ONE PIPE
SIZE. IF USING PEX-A AND ASTM F1960 COLD EXPANSION FITTINGS, UP-SIZING IS NOT REQUIRED.
SANITARY, WASTE AND VENT (DWV) & STORM SYSTEM:
1. ROUTE PIPING AS SHOWN. MAKE ALL CHANGES IN DIRECTION FOR PIPING USING APPROPRIATE "Y" BRANCHES,
STRAIGHT TEES AND ELBOWS. MAKE NO CHANGE IN DIRECTION OF FLOW GREATER THAN 90 DEGREES.
REDUCTION OF THE SIZE OF PIPING IN THE DIRECTION OF FLOW IS PROHIBITED. SLOPE PIPING A MINIMUM OF
1/8 INCH PER FOOT.
2. ALL LOCATIONS - NO-HUB CAST IRON WITH GASKETED JOINTS FOR ALL BURIED STORM AND SANITARY PIPING.
DWV (SCH. 40) SOLID WALL PVC WITH SOLVENT-WELDED JOINTS ACCEPTABLE ABOVE GRADE. STORM PIPING
MUST BE PROVIDED WITH 1" THICK CLOSED CELL ELASTOMERIC INSULATION. CELLULAR (FOAM) CORE PVC IS
AN UNACCEPTABLE SUBSTITUTION. (SOLID CORE PVC MAY BE SUBSTITUTED IN PLACE OF CAST-IRON WITH
WRITTEN APPROVAL FROM OWNER.) ALL BURIED PVC PIPE AND FITTINGS SHALL BE INSTALLED PER ASTM D
2321.
3. IF PLASTIC PIPING IS USED, PROVIDE SUITABLE EXPANSION JOINTS IN VERTICAL RISERS. FLASHING - AT
BUILT-UP ROOF, USE 4 LB. SHEET LEAD; AT METAL ROOF, COORDINATE WITH ROOF SYSTEM VENDOR.
4. PROVIDE CLEANOUTS PER CODE AND WHERE INDICATED AS FOLLOWS: FLOOR: ZURN ZN-1400, WALL: ZURN
Z-1441 WITH STAINLESS STEEL COVER EXTERIOR: ZURN ZN-1400-HD WITH RECESSED PLUG AND 12"X 12"X 4"
DEEP CONCRETE PAD.
5. FABRICATED PVC DWV FITTINGS SHALL CONFORM TO ASTM F 1866. PIPE AND FITTINGS SHALL BE
MANUFACTURED AS A SYSTEM AND BE THE PRODUCT OF ONE MANUFACTURER UNLESS WRITTEN APPROVAL
FROM OWNER IS PROVIDED.
NATURAL GAS
1. SCH. 40 BLACK STEEL WITH THREADED (1-1/2" AND SMALLER) OR WELDED (2" AND LARGER) JOINTS. INSTALL
PIPING IN ACCESSIBLE, VENTILATED SPACES AND PROVIDE SUITABLE SLEEVES UNDER SLABS ON GRADE AND
THRU PLENUMS.
2. WHERE GAS PIPING CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG THE FULL SIZE OF THE
SUPPLY PIPE, A 100% SHUT-OFF GAS COCK AND UNION.
3. PORTIONS OF A GAS PIPING SYSTEM INSTALLED IN CONCEALED LOCATIONS SHALL NOT HAVE UNIONS, TUBE
FITTINGS OR RUNNING THREADS.
4. BURIED STEEL PIPING TO BE PLASTIC COATED, WITH JOINTS TAPED. PROVIDE 17 LB. MAGNESIUM ANODE(S) AS
DIRECTED.
5. ALL EXPOSED, UNFINISHED PIPE, FITTINGS, SUPPORTS AND ACCESSORIES SHALL BE PREPARED FOR FINISH
PAINT. IN THE ABSENCE OF MORE STRINGENT SPECIFICATIONS, CONTRACTOR SHALL TOUCH-UP THE SURFACE
AS REQUIRED WITH A RUST-INHIBITIVE PRIMER RECOMMENDED BY TOP COAT MANUFACTURER AND THEN APPLY
TWO COATS OF LATEX ENAMEL IN A COLOR CONSISTENT WITH THE ANSI STANDARDS OR AS DIRECTED BY THE
OWNER/ARCHITECT.
COMPRESSED AIR
1. SCH. 40 BLACK STEEL WITH THREADED OR WELDED (2" AND LARGER) JOINTS.
2. WHERE COMPRESSED AIR PIPING CONNECTS TO EQUIPMENT, PROVIDED A SHUT-OFF VALVE, FILTER AND
REGULATOR ASSEMBLY EQUAL TO WILKERSON D28
MED GAS PIPING
1. SEAMLESS TYPE "K" HARD DRAWN COPPER WITH WROUGHT COPPER FITTINGS FOR BRAZED CONNECTIONS. ALL
PIPING SHALL BE PRE-CLEANED AND PLUGGED PRIOR TO SHIPMENT TO THE JOB SITE. MED GAS PIPING SYSTEMS
SHALL BE INSTALLED PER NFPA 99. ALL JOINTS TO BE MADE WITH 1000°F MELTING POINT MINIMUM 15% SILVER
BRAZING ALLOY. SYSTEMS SHALL BE PURGED CONTINUOUSLY WITH DRY NITROGEN WHILE BEING ASSEMBLED
AND BRAZED. USE OF FLUX IS NOT ALLOWED EXCEPT ON DISSIMILAR METALS. USE OF FLUX SHALL BE KEPT TO A
MINIMUM. CROSS CONNECTION TESTING AND CERTIFICATION OF THE MEDICAL GAS SYSTEM MUST BE
PERFORMED BY FACTORY TRAINED TECHNICIANS FROM THE MEDICAL GAS PIPELINE EQUIPMENT SUPPLIER.
MEDICAL GAS VALVE BOXES, VALVES, ALARMS, MANIFOLD, AND OUTLETS SHALL BE BY ONE MANUFACTURER.
VALVES BOXES SHALL BE BE MANUFACTURED BY CHEMETRON.
2. DISSIMILAR METALS SUCH AS COPPER AND BRASS SHALL BE JOINED USING AN APPROPRIATE FLUX WITH EITHER
A COPPER-PHOSPHORUS (BCUP SERIES) OR A SILVER (BAG SERIES) BRAZING FILLER METAL. APPLY FLUX
SPARINGLY TO THE CLEAN TUBE ONLY AND IN A MANNER TO AVOID LEAVING ANY EXCESS INSIDE OF
COMPLETED JOINTS.
ARGON
1. TYPE L HARD-DRAWN COPPER WITH SOLDERED JOINTS.
PLUMBING SPECIFICATIONS
________________________________________________________________________
BY DATE
05/31/2017
ENGINEERING & CONSTRUCTION
MANAGEMENT DEPARTMENT
PLUMBING REVIEW
These Plans Have Been Reviewed For General Conformity And
Permit May be Issued Subject To All Applicable Provisions Of
The City Plumbing and Gas Code.
__________________________________________________________
BY DATE
05/31/2017
C
D
H
C
14 15 16 17
D D
C C
A A
B B
E E
cen
F F
131211106 7 8 95431 2
G G
0.a 0.a
LOUNGE
1003
WORK ZONE
1002
VESTIBULE
1000
COMMAND
CENTER
1001
DINING
1004
GAME ZONE
1005
WATER/ICE
1008
ELEVATOR
LOBBY
1006
3500
2500
COORIDOR
1007A
WOMEN
1010
MEN
1011
DRYERS
019
CORRIDOR
1026
STAIR 2
S102
PBX
1028
OFFICE
1030
G.M. OFFICE
1029
MECH
1024
RISER ROOM
1025
FITNESS
1009
ELEV. EQUIP
1015
LAUNDRY
1017
LINEN STORAGE
1016
PASSAGE
1020
ELECTRICAL
1023
WATER ROOM
1021
JANITOR
1022
PANTRY
1027
STAIR 1
S101
EMPLOYEE
BREAK ROOM
1013
GUEST
CORRIDOR
1007B
SHAFT 1
LINEN
TERMINATION
1018
108
104
109
ACC KING
SHOWER
HEARING
107
105
103
101
KING
102
QQ HEARING
106
BREAKFAST
005
1
2
2
2
2
3
3
3
3
3
3
3 3
33
2 3
2
2
2
3
3
3
2
3
3
3
3
3
3
3
33
4
5
P3-01
3
PTAC-1
CCU-1
AHU-1
AHU-2
AHU-3
AHU-4
PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1 PTAC-1
PTAC-1
PTAC-1
3
PLUMB.PLUMB.
SD
SD
PLUMB.PLUMB.
SD
S
D
S
D
S
D
SD
PLUMB.PLUMB.
SD
PLUMB.PLUMB.
S
D
SD
PLUMB.PLUMB.
PLUMB.PLUMB.
SD
SD
S
D
PLUMB.PLUMB.
SD
SD
S
D
4" STORM
4" STORM
4" STORM4" STORM
6" STORM
6" STORM
6" STORM
6" STORM
6" STORM 6" STORM
6" STORM
6
6
6
6
6 6
7
8
9
6" BUILDING DRAIN
CO
WC-1
SH-1
2" SAN
WC-1
SH-1
WC-1
SH-1
2" SAN 2" SAN
WCO
WCO
4" SAN
4" SAN
WC-1
WC-1
2" SAN 2" SAN
WCO
4" SAN
WC-1
LAV-1
SH-1
2" SAN
4" SAN
WC-1
2" SAN
4" SAN
WC-2
SH-2
2" SAN
LAV-1
FD-1
WCO
WC-2
LAV-1
2" SAN
WCO
WCO
PLU
MB.
SP-1
SP-1
FD-1
FD-1 FD-1
6" BUILDING DRAIN6" BUILDING DRAIN6" BUILDING DRAIN6" BUILDING DRAIN
FD-3
WCO
WC-3WC-3
LAV-2LAV-2
FD-1
3" SAN
2" SAN
SK-2
SK-1
SK-5
SK-4
ECOECO ECOECO
EEW-1
1500 GALLON
GREASE TRAP
3" SAN
3" SAN
2" SAN
3" SAN
4" SAN
4" SAN
4" SAN
4" SAN
3" SAN
3" SAN
3" SAN
2" SAN
LAV-1 LAV-1
LAV-1
LAV-1
LAV-1LAV-1
MS-2
EEW-1
SK-3
2" VENT
3" GW
4" GW4" GW
2" VENT
2" VENT 2" VENT
3" VENT
2" VENT
1-1/2" VENT
1-1/2" VENT
2" VENT
3" VENT
3" GW
3" VENT
2" VENT
1-1/2" VENT
P4.01
1
CIVIL
CIVIL CIVIL CIVIL CIVIL
CIVIL CIVIL
CIVIL
4" SAN
4" SAN
2
SH-1
SH-1
SH-1
FD-1
SH-1
10
SD
S
D
6
EWC-1
MV-1
WH-3
WH-2
WH-1
WS-1
FD-2
P1-01
1
SCALE: 1/8"= 1'-0"
PLUMBING - WASTE & VENT - 1ST FLOOR
PLUMBING
WASTE & VENT
1ST FLOOR
P1-01
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
CLEANOUTS SHALL BE LOCATED IN THE SANITARY LINE EVERY 50' OR
CHANGE IN DIRECTION WHETHER SHOWN OR NOT.
a.
b.
c.
PLUMBING REFERENCED NOTES
COORDINATE LOCATION OF 1500 GALLON GREASE TRAP WITH CIVIL.
GREASE TRAP TO BE TRAFFIC RATED.
SANITARY PIPE ELBOW DOWN BELOW GRADE.
WASTE STACKS. SEE FLOOR ABOVE FOR STACK SIZE.
2" COPPER DISCHARGE FROM SUMP PUMP TO FLOOR SINK
PROVIDE FLOOR DRAIN UNDER ICE MACHINE.
4" STORM RISER TO BE ROUTED BELOW GRADE AND INCREASED TO
6"
COMMON VENT ALL WATER HEATER EXHAUST TO OUT DOORS PER
MANUFACTURES REQUIREMENTS. TERMINATE WITH
MANUFACTURER'S VENT TERMINATION KIT. ROUTE ABOVE GYPSUM
CEILING COORDINATE ROUTING WITH ALL TRADES.
ROUTE DRAIN FROM UNDER COUNTER DISH WASHER TO FLOOR SINK.
TERMINATE WITH AIR GAP.
3 COMP SINK TO SPILL INDIRECTLY TO FLOOR SINK. TERMINATE
WITH AIR GAP.
SEE LAUNDRY TRENCH DETAIL ON P6.03 FOR MORE INFORMATION.
1
2
3
4
5
6
7
8
9
10
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
D D
C C
A A
B B
E E
cen
F F
G G
ELEVATOR
LOBBY
2001
3500
2500
LINEN AND
STORAGE
2004
LINEN DROP
2002
ELECTRICAL
2003
CORRIDOR
2000
STAIR 2
S102
STAIR 1
S101
SHAFT 1
SHAFT 2
X501
LINEN
AREA OF
REFUGE
AREA OF
REFUGE
KING
213
211
KING HEARING
215
KING
217
KING
219
QQ CONNECTOR
212
ACC QUEEN
210
KING
226
KING
224
222
QQ HEARING
220
KING
218
KING
216
KING
214
208
206
204
KING
202
KING
227
KING
225
KING
223
KING HEARING
221
205
201
203
ACC KING
207
QQ CONECTOR
209
1
2
3
1
2
3
1
2
3
1
2
3 1
2
3
P3-01
2
P3-01
1
P3-01
5
P3-01
4
PTAC-1
PTAC-1
PTAC-1PTAC-1
PTAC-1PTAC-1
PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
PTAC-1
PTAC-1
PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1 PTAC-1
PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1
4
444
4
4 4
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
TUB-1
2" SAN
FD-1
2" SAN
SH-1
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
2" SAN
SH-1
WC-1
LAV-1
SH-1
WC-1
LAV-1
2" SAN 2" SAN
SH-1
WC-1
LAV-1
SH-1
WC-1
LAV-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
TUB-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
LAV-1
FD-1
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
cen cen
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
S302
3002
3004
3003
S301
ELEVATOR
LOBBY
3001
3500
X01
2500
X02
SHAFT 1
X500
LINEN AND
STORAGE
3004
LINEN DROP
3002
ELECTRICAL
3003
SHAFT 2
X501
CORRIDOR
3000
STAIR 2
S102
STAIR 1
S101
LINEN
X502
QQ CONNECTOR
312
ACC QUEEN
310
308
306
304
KING
302
KING
326
KING
324
322
320
KING
318
KING
316
KING
314
KING
327
KING
325
KING
323
KING
321
KING
319
KING
317
KING HEARING
315
KING
313
311
QQ CONNECTOR
309
ACC KING
307
305
303
301
1
2
3
1
2
3
1
2
3
1
2
3 1
2
3
PTAC-1
PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
PTAC-1
PTAC-1 PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1 PTAC-1
PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1
4
44444 4
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-2
LAV-1
TUB-2
2" SAN
FD-1
2" SAN
SH-1
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
2" SAN
SH-1
WC-1
LAV-1
SH-1
WC-1
LAV-1
2" SAN 2" SAN
SH-1
WC-1
LAV-1
SH-1
WC-1
LAV-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-2
TUB-2
2" SAN
WC-1
LAV-1
SH-1
2" SAN
LAV-1
FD-1
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
P1-02
1
SCALE: 1/8"= 1'-0"
PLUMBING - WASTE & VENT - 2ND FLOOR
PLUMBING
WASTE & VENT
2ND & 3RD FLOOR
P1-02
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
CLEANOUTS SHALL BE LOCATED IN THE SANITARY LINE EVERY 50' OR
CHANGE IN DIRECTION WHETHER SHOWN OR NOT.
a.
b.
c.
P1-03
2
SCALE: 1/8"= 1'-0"
PLUMBING - WASTE & VENT - 3RD FLOOR
PLUMBING REFERENCED NOTES
2" SANITARY STACK (TYPICAL OF ALL LAVATORY DISCHARGING
STACKS)
3" SANITARY STACK (TYPICAL OF ALL WATER CLOSET OR SHOWER
DISCHARGING STACKS)
3" VENT STACK (TYPICAL OF ALL VENT STACKS)
4" STORM RISER
1
2
3
4
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
ELECTRICAL
4003
S402
4003
4004
S401
ELEVATOR
LOBBY
4001
3500
X01
2500
X02
LINEN AND
STORAGE
4004
SHAFT 2
X501
LINEN DROP
4002
SHAFT 1
X500
LINEN
X502
STAIR 1
S101
CORRIDOR
4000
STAIR 2
S102
QQ CONNECTOR
412
QUEEN WIDE
410
KING
426
KING
424
422
QQ HEARING
420
KING
418
KING
416
KING
414
QQ HEARING
406
404
KING
402
KING
427
KING
423
KING HEARING
421
KING
419
KING
417
KING
415
KING
413
411
409
KING WIDE
407
405
403
401
408
KING
425
BUILDING
SIGNAGE
1
2
3
1
2
3
1
2
3
1
2
1
2
3
PTAC-1
PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1PTAC-1
PTAC-1
PTAC-1 PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1 PTAC-1
PTAC-1
PTAC-1 PTAC-1 PTAC-1
PTAC-1
3
5
5555
5
5
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
TUB-1
2" SAN
FD-1
2" SAN
SH-1
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
2" SAN
SH-1
WC-1
LAV-1
SH-1
WC-1
LAV-1
2" SAN 2" SAN
SH-1
WC-1
LAV-1
SH-1
WC-1
LAV-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
TUB-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
LAV-1
FD-1
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
WC-1
LAV-1
SH-1
2" SAN
4" VTR
4" VTR4" VTR
3" VENT 3" VENT
3" VENT
3" VENT
3" VENT 3" VENT
4" VTR
3" VENT
3" VENT3" VENT
4" VTR
3" VENT
3" VENT3" VENT
4" VTR
3" VENT
3" VENT3" VENT
4" VTR
3" VENT3" VENT3" VENT
3" VENT
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
cen
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
0.a 0.a
SLO
PE
1/4" P
ER
1'-0"
RD-1
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
RD-2 RD-3 RD-4
RD-5
RD-6 RD-7
2 HOUR ROOF OVER
STAIR SHAFT
2 HOUR ROOF OVER
STAIR SHAFT
ROOF ACCESS HATCH
MAKE-UP AIR
UNIT AREA
MAKE-UP AIR
UNIT AREA
WALKWAY
PROTECTION PAD
IN CONTRASTING
COLOR TO ROOF
TYP.
2 HOUR ROOF OVER
ELEVATOR SHAFT
SLOPE 1/4" PER 1'-0"
GUTTER &
DOWNSPOUT
BUILDING SIGNAGE
SCUPPER
SCUPPER
LINEN CHUTE
ROOF PARAPET
2 PARAPET VENTS BETWEEN
EACH DRAFT STOP (TYP.)
DRAFT STOP
AT MAX OF
EVERY 20'
ROOF PARAPET
2 PARAPET VENTS BETWEEN
EACH DRAFT STOP (TYP.)
DRAFT STOP
AT MAX OF
EVERY 20'
DRAFT STOP
AT MAX OF
EVERY 20'
SCUPPER
SCUPPER SCUPPER
DRAFT STOP
AT MAX OF
EVERY 20'
SLO
PE
SLO
PE
SLOPESLOPE
CANOPY BELOW
ROOF DRAIN /
DOWNSPOUT IN EIFS
COLUMN BUILD-OUT
ROOF DRAIN /
DOWNSPOUT IN EIFS
COLUMN BUILD-OUT
CANOPY BELOW
SLOPE SLOPE
SCUPPER & DOWNSPOUT
TO CONCRETE SPLASH
BLOCK, BOTH SIDES
BUILDING SIGNAGE
DRAFT STOP
AT MAX OF
EVERY 20'
DRAFT STOP
AT MAX OF
EVERY 20'
4 4 4
4
4 4 4
MAU-2
MAU-1
RD-1 RD-1 RD-1 RD-1 RD-1 RD-1 RD-1
4" VTR
4" VTR4" VTR
4" VTR
4" VTR 4" VTR
4" VTR
1961 SQ FT 1490 SQ FT 1466 SQ FT 1378 SQ FT
1741 SQ FT 1668 SQ FT
2024 SQ FT
6 6 6
6
6 6 6
PLUMBING
WASTE & VENT
4TH FLOOR & ROOF
P1-03
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
CLEANOUTS SHALL BE LOCATED IN THE SANITARY LINE EVERY 50' OR
CHANGE IN DIRECTION WHETHER SHOWN OR NOT.
a.
b.
c.
PLUMBING REFERENCED NOTES
2" SANITARY STACK (TYPICAL OF ALL LAVATORY DISCHARGING
STACKS)
3" SANITARY STACK (TYPICAL OF ALL WATER CLOSET OR SHOWER
DISCHARGING STACKS)
3" VENT STACK (TYPICAL OF ALL VENT STACKS)
4" STORM DRAIN
4" STORM RISER
6" STORM OVER FLOW THRU PARAPET WALL SLOPE AT 1/8" PER
FOOT. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF
SCUPPER DRAINS.
1
2
3
4
P1-03
1
SCALE: 1/8"= 1'-0"
PLUMBING - WASTE & VENT - 4TH FLOOR
P1-03
2
SCALE: 1/8"= 1'-0"
PLUMBING - WASTE & VENT - ROOF PLAN
5
6
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
C
D
H C
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
cen
F F
13
13
12
1211
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
0.a 0.a
LOUNGE
1003
WORK ZONE
1002
VESTIBULE
1000
COMMAND
CENTER
1001
DINING
1004
GAME ZONE
1005
WATER/ICE
1008
ELEVATOR
LOBBY
1006
3500
2500
COORIDOR
1007A
WOMEN
1010
MEN
1011
DRYERS
019
CORRIDOR
1026
STAIR 2
S102
PBX
1028
OFFICE
1030
G.M. OFFICE
1029
MECH
1024
RISER ROOM
1025
FITNESS
1009
ELEV. EQUIP
1015
LAUNDRY
1017
LINEN STORAGE
1016
PASSAGE
1020
ELECTRICAL
1023
WATER ROOM
1021
JANITOR
1022
PANTRY
1027
STAIR 1
S101
EMPLOYEE
BREAK ROOM
1013
GUEST
CORRIDOR
1007B
SHAFT 1
LINEN
TERMINATION
1018
108
104
109
ACC KING
SHOWER
HEARING
107
105
103
101
KING
102
QQ HEARING
106
BREAKFAST
005
PLUMB.
CIVIL
3
2
3
4
5 2
3
2
3
2
3
2
3
2
3
2
32
3
2
3
3
3
3
33333
3
22
33333
3
6
13
14
G
16
18
P3-01
3
3" CW (UNDER SLAB)
1" 140° HW
3/4" HWR
2" HW
2-1/2" CW
3/4" 140° HW
1-1/4" (2PSI) GAS
MS-2
SK-5
SK-2
SK-1
FPHB-1
FD-1
WC-3
WC-3
FD-1
LAV-2 LAV-2
FPHB-1
2" CW
2" HW
2" CW
2" HW
2-1/2" CW
2" HW1" CW
1" HW
1" CW
1" HW
1" 140° HW
1-1/4" (2PSI) GAS
3/4" 140° HWR
1-1/4" CW
1-1/4" HW
1-1/2" CW
1-1/2" HW
1-1/2" CW
1-1/2" HW
1/2" HW
1" 140° HW
3/4" 140° HWR
3/4" CW
3/4" CW
1/2" HW
1/2" CW
1/2" CW 3/4" CW
1-1/2" HW
1-1/2" CW
1/2" CW
3/4" CW
3/4" 140° HWR
EWC-1
MS-1
FPHB-1
FPHB-1
3/4" CW
3/4" CW
FPHB-1
1-1/2" CW
EEW-1
1" 140° HW
SK-4
20
SK-3
3/4" 140° HW
6
CS-3
3/4" 140° HW
3/4" CW
FPHB-1
3/4" CW
3/4" HW
3/4" HWR
1-1/4" CW
3/4" (2 PSI) GAS
1-1/2" 140° HW
3/4" HW
3/4" HWR
1-1/4° CW
7
8
11
12
10
17
6
G
G
FD-1
21
G
15
GM
PLUMB.
CIVIL
1-1/4" (2PSI) GAS
G
G
1-1/4" (2PSI) GAS
G G
1
1-1/2" (2psi) GAS
9
3" CW
1-1/2" CW
19
MV-1
WH-3
WH-2
WH-1
6
WS-1
CS-1
CS-2
P2-01
1
SCALE: 1/8"= 1'-0"
PLUMBING - DOMESTIC & GAS - 1ST FLOOR
PLUMBING
DOMESTIC & GAS
1ST FLOOR
P2-01
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
CLEANOUTS SHALL BE LOCATED IN THE SANITARY LINE EVERY 50' OR
CHANGE IN DIRECTION WHETHER SHOWN OR NOT.
a.
b.
c.
PLUMBING REFERENCED NOTES
1" (2PSI) GAS RISER
PROVIDE 1/4 SHUT OFF VALVE WITH 3/4" CW & HW TO EACH ROOM.
LOCATE SHUT OFF VALVES IN CORRIDOR CEILING SPACE ABOVE
REMOVABLE CEILING. TYPICAL OF EACH UNIT.
3/4" CW & HW UP TO SECOND FLOOR.
2" CW & HW RISER.
1-1/2" CW & HW RISER.
PROVIDE 1/2" TRAP PRIMER CONNECTION TO FLOOR DRAIN.
SEE DETAIL ON P6-00 FOR BOILER AND STORAGE TANK PIPING
SCHEMATIC.
MASTER MIXING VALVE TO BE LOCATED ON WALL. SEE P600 FOR
MIXING VALVE SCHEMATIC.
3" DOMESTIC COLD WATER ELBOW UP. PROVIDE WITH SHUT OFF
VALVE.
PROVIDE 1" 140° HW CONNECTION TO SUPPLY WASHER
PROVIDE 1/4 TURN SHUTDOWN VALVE TO LBS TO INCHES
REGULATOR DOWN TO EQUIPMENT. SEE EQUIPMENT SPEC. SHEET
FOR REGULATOR SETTINGS.
PROVIDE 1" CW CONNECTIO TO DRYER FIRE SUPPRESSION SYSTEM.
COORDINATE SUPPLY CONNECTIONS WITH MANUFACTURE'S MANUAL.
PROVIDE 1/2" CONNECTION TO JUICE DISPENSER LOCATED IN
BREAKFAST AND COFFEE AREA, VERIFY LOCATION WITH
ARCHITECTURAL PLANS.
1
2
3
4
5
6
7
8
9
10
11
12
13
PROVIDE 3/4" 140° HW CONNECTION TO UNDER COUNTER DISH
WASHER. REFER TO FOOD SERVICE EQUIPMENT VENDOR FOR SPEC
SHEETS. CONFIRM LOCATION WITH ARCHITECTURAL PLANS.
COORDINATE LOCATION OF NATURAL GAS METER WITH UTILITY
COMPANY (INPUT: 2608 MBH). SLEEVE BUILDING PENETRATION
WEATHER TIGHT.
PROVIDE 1/2" CW CONNECTION IN RECESSED OUTLET BOX FOR ICE
MACHINE.
PROVIDE CW CONNECTION TO BOTTLE FILL STATION. REFER TO
FINAL EQUIPMENT SPECIFICATIONS FOR ROUGH IN SIZE.
PROVIDE 1/2" CONNECTION TO ELECTRIC WATER COOLER.
ROVIDE 3/4" CW CONNECTION TO FROST PROOF HOSE BIB IN
DUMPSTER ENCLOSURE. CW PIPE SHOULD BE SLEEVED AND ROUTED
BELOW FROST LINE. FIELD COORDINATE EXACT LOCATION WITH
GROUND FLOOR PLAN.
PROVIDE 1/2" CW CONNECTION TO COFFEE BREWER
3/4" CW CONNECTION TO ENCASED WALL HYDRANT ZURN Z1320-C IN
BATHROOMS 1012 AND 1013. LOCATE WALL BOX UNDER LAVATORY.
3' X 7' FOOT PRINT RESERVED FOR WATER SOFTENER EQUIPMENT.
COORDINATE EQUIPMENT LAYOUT WITH WATER SOFTENER
SUPPLIER.
14
15
16
17
18
19
20
21
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
22
________________________________________________________________________
BY DATE
05/31/2017
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
cen
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
ELEVATOR
LOBBY
2001
3500
2500
LINEN AND
STORAGE
2004
LINEN DROP
2002
ELECTRICAL
2003
CORRIDOR
2000
STAIR 2
S102
STAIR 1
S101
SHAFT 1
SHAFT 2
X501
LINEN
AREA OF
REFUGE
AREA OF
REFUGE
KING
213
211
KING HEARING
215
KING
217
KING
219
QQ CONNECTOR
212
ACC QUEEN
210
KING
226
KING
224
222
QQ HEARING
220
KING
218
KING
216
KING
214
208
206
204
KING
202
KING
227
KING
225
KING
223
KING HEARING
221
205
201
203
ACC KING
207
QQ CONECTOR
209
P3-01
2
P3-01
1
P3-01
5
P3-01
4
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
5
6
1
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
cen cen
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
S302
3002
3004
3003
S301
ELEVATOR
LOBBY
3001
3500
X01
2500
X02
SHAFT 1
X500
LINEN AND
STORAGE
3004
LINEN DROP
3002
ELECTRICAL
3003
SHAFT 2
X501
CORRIDOR
3000
STAIR 2
S102
STAIR 1
S101
LINEN
X502
QQ CONNECTOR
312
ACC QUEEN
310
308
306
304
KING
302
KING
326
KING
324
322
320
KING
318
KING
316
KING
314
KING
327
KING
325
KING
323
KING
321
KING
319
KING
317
KING HEARING
315
KING
313
311
QQ CONNECTOR
309
ACC KING
307
305
303
301
2
4
2
4
2
4
2
4
2
4
2
4
2
4
2
4
5
6
2" CW
2" HW
2" CW
2" HW
2" CW
2" HW
2" CW
1-1/2" HW
2" CW
1-1/2" HW
1-1/2" CW
1-1/2" HW
1-1/2" CW
1-1/2" HW
1-1/2" CW
1-1/2" HW
3/4" CW
7
1
P2-02
1
SCALE: 1/8"= 1'-0"
PLUMBING - DOMESTIC & GAS - 2ND FLOOR
PLUMBING
DOMESTIC & GAS
2ND & 3RD FLOOR
P2-02
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
CLEANOUTS SHALL BE LOCATED IN THE SANITARY LINE EVERY 50' OR
CHANGE IN DIRECTION WHETHER SHOWN OR NOT.
a.
b.
c.
PLUMBING REFERENCED NOTES
1" (2PSI) GAS RISER
PROVIDE 1/4 SHUT OFF VALVE WITH 3/4" CW & HW TO EACH ROOM.
LOCATE SHUT OFF VALVES IN CORRIDOR CEILING SPACE ABOVE
REMOVABLE CEILING. TYPICAL OF EACH UNIT.
3/4" CW & HW FROM FIRST FLOOR. TYPICAL OF EACH UNIT.
3/4" CW & HW UP TO FOURTH FLOOR.
2" CW & HW RISER.
1-1/2" CW & HW RISER.
3/4" CW UP TO ROOF TO SERVE FREEZE PROOF POST HYDRANT.
1
2
3
5
6
P2-02
2
SCALE: 1/8"= 1'-0"
PLUMBING - DOMESTIC & GAS - 3RD FLOOR
4
7
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
ELECTRICAL
4003
S402
4003
4004
S401
ELEVATOR
LOBBY
4001
3500
X01
2500
X02
LINEN AND
STORAGE
4004
SHAFT 2
X501
LINEN DROP
4002
SHAFT 1
X500
LINEN
X502
STAIR 1
S101
CORRIDOR
4000
STAIR 2
S102
QQ CONNECTOR
412
QUEEN WIDE
410
KING
426
KING
424
422
QQ HEARING
420
KING
418
KING
416
KING
414
QQ HEARING
406
404
KING
402
KING
427
KING
423
KING HEARING
421
KING
419
KING
417
KING
415
KING
413
411
409
KING WIDE
407
405
403
401
408
KING
425
BUILDING
SIGNAGE
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
5
14
14
15
15
16
16
17
17
D D
C C
A A
B B
E E
cen
F F
13
13
12
12
11
11
10
10
6
6
7
7
8
8
9
9
5
5
4
4
3
3
1
1
2
2
G G
0.a 0.a
SLO
PE
1/4" P
ER
1'-0"
RD-1
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
SLO
PE
1/4" P
ER
1'-0"
RD-2 RD-3 RD-4
RD-5
RD-6 RD-7
2 HOUR ROOF OVER
STAIR SHAFT
2 HOUR ROOF OVER
STAIR SHAFT
ROOF ACCESS HATCH
MAKE-UP AIR
UNIT AREA
MAKE-UP AIR
UNIT AREA
WALKWAY
PROTECTION PAD
IN CONTRASTING
COLOR TO ROOF
TYP.
2 HOUR ROOF OVER
ELEVATOR SHAFT
SLOPE 1/4" PER 1'-0"
GUTTER &
DOWNSPOUT
BUILDING SIGNAGE
SCUPPER
SCUPPER
LINEN CHUTE
ROOF PARAPET
2 PARAPET VENTS BETWEEN
EACH DRAFT STOP (TYP.)
DRAFT STOP
AT MAX OF
EVERY 20'
ROOF PARAPET
2 PARAPET VENTS BETWEEN
EACH DRAFT STOP (TYP.)
DRAFT STOP
AT MAX OF
EVERY 20'
DRAFT STOP
AT MAX OF
EVERY 20'
SCUPPER
SCUPPER SCUPPER
DRAFT STOP
AT MAX OF
EVERY 20'
SLO
PE
SLO
PE
SLOPESLOPE
CANOPY BELOW
ROOF DRAIN /
DOWNSPOUT IN EIFS
COLUMN BUILD-OUT
ROOF DRAIN /
DOWNSPOUT IN EIFS
COLUMN BUILD-OUT
CANOPY BELOW
SLOPE SLOPE
SCUPPER & DOWNSPOUT
TO CONCRETE SPLASH
BLOCK, BOTH SIDES
BUILDING SIGNAGE
DRAFT STOP
AT MAX OF
EVERY 20'
DRAFT STOP
AT MAX OF
EVERY 20'
MAU-2
MAU-1
1/2" (2PSI) GAS
G
3/4" (7") GAS
4
1/2" (2PSI) GAS
G
3/4" (7") GAS
4
6
RHB-1
1
1" (2PSI) GAS 3/4" (2PSI) GAS
1" (2PSI) GAS
G
G G G
PLUMBING
DOMESTIC & GAS
4TH FLOOR & ROOF
P2-03
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
CLEANOUTS SHALL BE LOCATED IN THE SANITARY LINE EVERY 50' OR
CHANGE IN DIRECTION WHETHER SHOWN OR NOT.
a.
b.
c.
PLUMBING REFERENCED NOTES
1" (2PSI) GAS RISER
PROVIDE 1/4 SHUT OFF VALVE WITH 3/4" CW & HW TO EACH ROOM.
LOCATE SHUT OFF VALVES IN CORRIDOR CEILING SPACE ABOVE
REMOVABLE CEILING. TYPICAL OF EACH UNIT.
3/4" CW & HW FROM THIRD FLOOR. TYPICAL OF EACH UNIT.
PROVIDE SHUT OFF VALVE WITH LBS TO INCHES REGULATOR TO
EQUIPMENT, SEE EQUIPMENT SPEC SHEET FOR REGULATOR
SETTINGS.
3/4" CW UP TO ROOF.
PROVIDE FREEZE PROOF POST HYDRANT ZURN Z1388 OR
EQUIVALENT.
1
2
3
P2-03
1
SCALE: 1/8"= 1'-0"
PLUMBING - DOMESTIC & GAS - 4TH FLOOR
P2-03
2
SCALE: 1/8"= 1'-0"
PLUMBING - DOMESTIC & GAS - ROOF PLAN
4
5
6
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
A5-03
5
8
67
G02
G01
ABOVE
5
'
-
0
"
T
U
R
N
D
I
A
M
E
T
E
R
PARALLEL APPROACH 30" X 48"
DOOR + 24" X 60"
DOOR + 18" X 60"
36" WIDE ROUTE AROUND BED
PA
RA
LL
EL
A
PP
RO
AC
H 3
0" X
4
8"
G03
DOOR + 18" X 60"
TUB-2
WC-2
LAV-1
4
FD-1
3/4" CW
3/4" HW
3/4" CW
1/2" HW
1/2" CW
2
3
5 1
G02
G01
SE
E D
ET
AIL
3
O
N S
HE
ET
A
1.0
1
ABOVE
SH-1
WC-1
LAV-1
2
3
5
3/4" CW
3/4" HW
3/4" CW
1/2" HW
1/2" CW
1
A5-04
5
76
8
SE
E D
ET
AIL 3 O
N S
HE
ET
A
1.01
W60K1
W40A0
G02
G01
G03
MIN. CLEARANCE
5
'
-
0
"
T
U
R
N
D
I
A
M
E
T
E
R
PA
RA
LLE
L A
PP
RO
AC
H 30" X
48"
PARALLEL APPROACH 30" X 48"
PA
RA
LLE
L A
PP
RO
AC
H 30" X
48"
DOOR + 24" X 60"
DOOR + 18" X 60"
F.D.
F.D.
DOOR + 18" X 60"
TUB-2
WC-2
LAV-1
3/4" CW
3/4" HW
3/4" CW
1/2" HW
1/2" CW
2
3
5
1
4
FD-1
SE
E D
ET
AIL
3
O
N S
HE
ET
A
1.0
1
W40A0
W40E0
G02
GO1
SH-1
WC-1
LAV-1
2
3
5
3/4" CW
3/4" HW
3/4" CW
1/2" HW
1/2" CW
1
A5-05
5
67
8
A5-09
4C
4B
ABOVE
5
'
-
0
"
T
U
R
N
D
I
A
M
E
T
E
R
PARALLEL APPROACH 30" X 48"
DOOR + 24" X 60"
DOOR + 18" X 60"
36" WIDE ROUTE AROUND BED
PA
RA
LLE
L A
PP
RO
AC
H 30" X
48"
F.D.
F.D.
SH-2
WC-2
LAV-1
4
FD-1
3/4" CW
3/4" HW
3/4" CW
1/2" HW
1/2" CW
2
3
5 1
SE
E D
ET
AIL 3 O
N S
HE
ET
A
1.01
W40E0
ABOVE
TUB-1
WC-1
LAV-1
3/4" CW
3/4" HW
3/4" CW
1/2" HW
1/2" CW
2
3
5
1
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
PLUMBING
LARGE SCALE
ROOM PLAN
P3-01
P3-01
4
SCALE: 1/2"= 1'-0"
PLUMBING - LSRP - QUEEN
P3-01
5
SCALE: 1/2"= 1'-0"
PLUMBING - LSRP - ACC QUEEN
PLUMBING UNREFERENCED NOTES
SEE SHEET P0-01 FOR GENERAL PLUMBING NOTES.
FOR FIXTURE CONNECTION SIZES REFER TO FIXTURE SCHEDULE
SHEET ON P5-00.
a.
b.
PLUMBING REFERENCED NOTES
3/4" CW & 3/4" HW TO FIXTURE. CONTRACTOR TO COORDINATE
VALVE LOCATION AND ORIENTATION WITH ARCHITECTURAL PRIOR
TO INSTALLATION.
1/2" CW & 1/2" HW DOWN TO FIXTURE.
3/4" CW DOWN TO FIXTURE.
PROVIDE 1/2" TRAP PRIMER TO FLOOR DRAIN. SEE DETAIL ON
DETAILS SHEET FOR CLARITY.
ALL ROOMS TO RECEIVE 3/4" CW & HW. EACH ROOM TO HAVE CW &
HW 1/4 TURN SHUT OFF VALVES. PROVIDE ACCESS PANEL AS REQ'D
TO ACCESS VALVES
1
2
3
4
5
P3-01
2
SCALE: 1/2"= 1'-0"
PLUMBING - LSRP - KING
P3-01
1
SCALE: 1/2"= 1'-0"
PLUMBING - LSRP - ACC KING
P3-01
3
SCALE: 1/2"= 1'-0"
PLUMBING - LSRP - ACC KING SHOWER HEARING
P3-01
6
SCALE: 1/2"= 1'-0"
PLUMBING - LSRP - KING WIDE
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
RISER DIAGRAM
P4-00
P4-00
1
SCALE: NONE
PLUMBING - RISER DIAGRAM - KING TYP.
P4-00
2
SCALE: NONE
PLUMBING - RISER DIAGRAM - Q/Q TYP.
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
COLUMN LINE "D"
DRAIN, WASTE, AND
VENT STACK (TYP.)
45° ELBOW (TYP.)
"W" SECTION BEAM
NOTE:TYPICAL OF ALL DWV
STACKS ON COLUMN "C" & "D"
IN COMMAND CENTER AREA.
CLEANOUT TEE
CLEANOUT PLUG
COUNTERSUNK SCREW
POLISHED S.S. ACCESS COVER
PLUMBING
RISER DIAGRAM
P4-01
P4-01
1
SCALE: NONE
PLUMBING - RISER DIAGRAM - "C" & "D" COLUMN
P4-01
2
SCALE: NONE
PLUMBING - "C" & "D" COLUMN BEAM COORDINATION
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
RISER DIAGRAM
P4-02
2ND FLOOR
4TH FLOOR
ROOF
GG
1" GAS (2 PSI)
3RD FLOOR
LBS TO INCHES REGULATOR
(TYPICAL)
1-1/2" GAS (2PSI)
3/4" GAS (7" WC)
G
G
3/4" GAS (7" wc)
3/4" GAS (2 PSI)
3/4" GAS (7" wc)
LBS TO INCHES REGULATOR
(TYPICAL)
DRYER
(135 MBH)
MAU-1
(150 MBH)
MAU-2
(300 MBH)
DRYER
(135 MBH)
3/4" GAS (2 PSI)
GAS METER & REGULATOR
BY UTILITY COMPANY
1ST FLOOR
GG
2ND FLOOR
4TH FLOOR
3RD FLOOR
ROOF
1ST FLOOR
WATER HEATERS BFP
TO MECHANICAL
ROOM REFER TO
P6.00 FOR PIPING
SCHEMATIC
RCP-1CS-1
1" CW
1" HW
1-1/2" CW
1-1/2" HW
1-1/2" CW
1-1/4" HW
2" HW
2-1/2" CW
2" CW
2" HW
2" HW
2" CW
2" CW
1-1/2" HW
2" CW
2" HW
1-1/2" CW
3/4" CW & HW SUPPLY WITH
1/4 SHUT OFF VALVE TYPICAL
OF EACH GUEST ROOM
2-1/2" CW
2" HW
3/4" HWR
3/4" CW & HW SUPPLY WITH
1/4 SHUT OFF VALVE TYPICAL
OF EACH GUEST ROOM
3/4" CW & HW SUPPLY WITH
1/4 SHUT OFF VALVE TYPICAL
OF EACH GUEST ROOM
P4-02
1
SCALE: NONE
PLUMBING - RISER DIAGRAM - GAS RISER DIAGRAM
P4-02
2
SCALE: NONE
PLUMBING - RISER DIAGRAM - DOMESTIC RISER
1" GAS (2 PSI)
1-1/4" GAS (2PSI)
3/4" GAS (7" WC)
1-1/2" CW
1-1/2" HW
1-1/2" HW
2" CW
2" HW
1-1/4" CW
1" HW
3/4" GAS (7" WC)
DRYER
(135 MBH)
SHUT OFF VALVE (TYPICAL)
LBS TO INCHES REGULATOR (TYPICAL)
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
1" GAS (2 PSI)
G
WH-1
WATER
HEATER
(751 MBH)
1" GAS
(2PSI)
WH-2
WH-3
WATER
HEATER
(751 MBH)
WATER
HEATER
(251 MBH)
1-1/4" GAS 1-1/4" GAS
2" GAS 2" GAS
G GG
SHUT OFF VALVE W/
LBS-TO-INCHES REGULATOR
SEE EQPM SPEC SHEET FORE
PRESSURE REQUIREMENTS.
3/4" GAS
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
SCHEDULES
P5-00
PLUMBING FIXTURE SCHEDULE
ITEM DESCRIPTION MANUFACTURER CATALOG #
FAUCET/VALVE
TRIM SUPPLIES WASTE TRAP
ROUGH-IN (INCHES)
C.W. H.W. WASTE VENT
WC-1
GUEST ROOM WATER CLOSET
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - INTEGRAL
3/4"
- 4" 2"
WC-2
ADA GUEST ROOM WATER CLOSET
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - INTEGRAL
3/4"
- 4" 2"
WC-3
PUBLIC WATER CLOSET
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - INTEGRAL 1" - 4" 2"
LAV-1
GUEST ROOM LAVATORY
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2" 1-1/2" 1-1/2"
LAV-2
PUBLIC LAVATORY
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2" 1-1/2" 1-1/2"
SH-1
GUEST ROOM SHOWER
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2"
2"
1-1/2"
SH-2
ADA GUEST ROOM SHOWER
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
TUB-1
GUEST ROOM TUB
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
TUB-2
ADA GUEST ROOM TUB
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
SK-1
LAUNDRY ROOM SERVICE SINK
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
SK-2
EMPLOYEE BREAK ROOM SINK
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
SK-3
PANTRY HAND SINK
COORDINATE SELECTION WITH FOOD SERVICE EQUIPMENT
VENDOR
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
SK-4
PANTRY 3 COMPARTMENT SINK
COORDINATE SELECTION WITH FOOD SERVICE EQUIPMENT
VENDOR
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
SK-5
WORK TABLE SINK
COORDINATE SELECTION WITH FOOD SERVICE EQUIPMENT
VENDOR
- - - - - - P-TRAP
1/2" 1/2"
2"
1 1/2"
MS-1
JANITOR MOP SINK
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
3/4" 3/4"
2"
1 1/2"
MS-2
JANITOR MOP SINK
COORDINATE FIXTURE SELECTION WITH FOOD SERVICE
EQUIPMENT VENDOR
- - - - - - P-TRAP
3/4" 3/4"
2"
1 1/2"
EWC-1
ELECTRIC WATER COOLER
COORDINATE FIXTURE SELECTION WITH FIXTURE MATRIX
- - - - - - P-TRAP
1/2"
-
1-1/2" 1-1/4"
EEW-1 EMERGENCY EYE WASH BRADLEY S19224 - - - - -
1/2" 1/2" 1-1/2" 1-1/2"
CO FLOOR CLEANOUT ADJUSTABLE TO FF. ZURN ZN-1400 - - - - - - - - -
ECO
CLEANOUT ADJUSTABLE TO FINISHED GRADE. POLISHED
NICKEL BRONZE ROUND SCORIATED SECURED TOP WITH
RECESSED PLUG. PROVIDE 12"x12"x4" CONCRETE PAD
ZURN ZN-1400-HD - - - - - - - - -
WCO
WALL CLEANOUT ROUND SS ACCESS COVER WITH SECURING
SCREEN
ZURN Z-1441 - - - - - - - - -
TP-1 TRAP PRIMER FOR 1 DRAIN ZURN Z1022 - - - - -
1/2"
- - -
FS-1 12"x12" FLOOR SINK ZURN ZN-1900 - - - - P-TRAP - -
SEE
PLAN
-
FPHB-1
FREEZE PROOF HYDRANT WITH INTEGRAL VACUUM BREAKER
AND BOX
ZURN Z-1320 - - - - -
3/4"
- - -
RHB-1 SELF DRAINING FREEZE PROOF POST HYDRANT ZURN Z-1388 - - - - -
3/4"
- - -
FD-1 FLOOR DRAIN WITH 5" TOP. ZURN ZN-415-5B - - - - P-TRAP - - 4" 2"
FD-2
12IN. DIAMETER FLOOR DRAIN W/ DUCTILE IRON TOPZURN Z541 - - - - P-TRAP - - 4" 2"
FD-3
6" X 9" MEDIUM-DUTY HINGED DRAIN (USED IN LAUNDRY
TENCH), CAST IRON BODY WITH 3" BOTTOM OUTLET, SEEPAGE
PAN WITH SUSPENDED SEDIMENT BUCKET
ZURN Z585 - - - - P-TRAP - - 3"
1-1/2"
RD-1 ROOF DRAIN WITH DECK PLATE AND ADJ. EXTENSION ZURN ZC100-DP-EA - - - - - - - 4" -
NOTES:
1. PROVIDE THERMOSTATIC MIXING VALVE SYMMONS #7-210-CK FOR PUBLIC LAVATORIES & SINKS.
2. PROVIDE EEW-1 WITH BRADLEY S19-2000 THERMOSTATIC MIXING VALVE SET AT 85°F.
3. COORDINATE FIXTURES WITH FIXTURE MATRIX AND BRAND STANDARDS.
ELEVATOR SUMP PUMP SCHEDULE
ITEM MANUFACTURER CATALOG # HP GPM
HEAD (FT)
VOLTAGE
SP-1 ZOELLER 153-002
1/2
50 22
115/1∅
PROVIDE COMPLETE "OIL SMART" PUMP SYSTEM WITH ALARM.
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
WATER SOFTENER SCHEDULE
ITEM MANUFACTURER CATALOG #
FLOW (GPM)
INLET-OUTLET
WS-1 CULLIGAN SYSTEMS CTM-300 HWB NHWB MT 95 2" - 2"
CIRCUIT SETTER SCHEDULE
ITEM MANUFACTURER CATALOG #
FLOW (GPM)
INLET-OUTLET
CS-1 ARMSTRONG
CBV-3/4" MS
4.0
3/4" - 3/4"
CS-2 ARMSTRONG
CBV-3/4" MS
3.5
3/4" - 3/4"
CS-3 ARMSTRONG
CBV-3/4" MS
1.0
3/4" - 3/4"
MIXING VALVE SCHEDULE
ITEM MANUFACTURER MODEL
FLOW RATE (gpm)
TEMPERATURE SETTING
MV-1 ARMSTRONG DRV50R 60 120°
RECIRCULATING PUMP SCHEDULE
ITEM MANUFACTURER CATALOG # HP VOLTAGE NOTES
RCP-1 GRUNDFOS UP2699-BF
1/6 120/1∅ 3 SPD PUMP W/ INTEGRAL CHECK
RCP-2 GRUNDFOS UP2699-BF
1/6 120/1∅ 3 SPD PUMP W/ INTEGRAL CHECK
PROVIDE GRUNFOS #595657 AQUASTAT FOR RCP-1.
TANKLESS WATER HEATER SCHEDULE
ITEM MANUFACTURER CATALOG #
INPUT (MBH)
GAS CONN. CONTROL
WH-1 INTELLIHOT
iQ751
751
1 1/4"
INTEGRAL
WH-2 INTELLIHOT
iQ751
751
1 1/4"
INTEGRAL
WH-3 INTELLIHOT
iQ251
251
3/4"
INTEGRAL
PROVIDE CONDENSATE NEUTRALIZATION KIT.
PROVIDE WITH MANUFACTURE'S CONCENTRIC VENT KIT.
EXPANSION TANK SCHEDULE
MARK MFGR. MODEL SIZE REMARKS
ET-1
ZURN/WILKINS
WTTA-30 15 GALLON -
ET-2
ZURN/WILKINS
WTTA-5 3.5 GALLON -
NOTE:
1. TANK PRECHARGED AT 40 psi. ADJUST AIR PRECHARGE AS REQUIRED TO EQUAL INCOMING WATER PRESSURE.
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
DETAILS
P6-00
SYMMONS MODEL 7-210-CK
THERMOSTATIC TEMPERING
VALVE. SET DISCHARGE
TEMP TO 110°.
COUNTER
TEMPERED WATER
1/2" CW SUPPLY1/2" HW SUPPLY
1 1/4" O.D. WASTE
1 1/4" O.D. TAILFACE
FINISHED FLOOR
LOCAL MIXING VALVE DETAIL
1/2" #10 SCREW
PROVIDE & INSTALL AN
ADDITIONAL SHEET OF ROOFING
MATERIAL OR A TRAFFIC PAD AS
DIRECTED BY ROOFING
MANUFACTURER.
NOTE: PROVIDE SUFFICIENT ROOM
BETWEEN THE PIPE AND STRAP TO
PROVIDE FOR FREE MOVEMENT OF
THE PIPE WITHOUT BINDING.
ELEVATIONS)
SPACER (TO INCREASE
2"
SIDE VIEWFRONT VIEW
TOP VIEW
7 1/2"
7 1/2"
GAS PIPING
"MIRO" PILLOW BLOCK PIPESTAND
MODEL NO. 3-R OR APPROVED
EQUAL. PROVIDE GAS SUPPORTS AT
10'-0" ON CENTER & AT ALL BENDS.
CLAMP (UNISTRUT TYPE)
SCALE: NONE
GAS PIPING ROOF SUPPORT
12" M
IN
.
DRAW BAND
ROOF
NOT INSULATED
8" MIN.
3" MIN.
ROOF DECK
REQUIRED
ROOF
12" M
IN
.
ROOF DECK
LEAD FLASHING
INSULATED
8" MIN.
VENT STACK
TURN LEAD FLASHING
INTO PIPE 3" MIN.
INCREASER WHEN
(SEE PLAN FOR SIZES)
CAST IRON PIPE (OR PVC
WHERE ALLOWED)
SCALE: NONE
VENT THRU ROOF DETAIL
SLEEVE ROOF
CONSTRUCTION AS
REQUIRED
SCALE: NONE
SCALE: NONE
WATER HEATER CIRCULATING PUMP SCHEMATIC
WATER HEATER
THERMOSTATIC
MIXING VALVE
BALANCING VALVE
THERMOMETER
THERMOMETER
BALL VALVE
TEMPERED HOT WATER TO FIXTURES
CHECK
BALANCING VALVE
CIRCULATING PUMP
BALL VALVE
THERMOMETER
CHECK
COLD WATER SUPPLYCW
CW
CW
HWR
HWR
HW
R
HWTHW THW
TEMPERED HOT WATER TO FIXTURES
TEMPERED HOT WATER TO FIXTURES
TEMPERED HOT WATER TO FIXTURES
TEMPERED HOT WATER TO FIXTURES
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
SCALE: NONE
WATER HEATER PIPING SCHEMATIC
WH-1
(Setpoint 130°F)
WH-2
(Setpoint 130°F)
NOTES:
1. FOR PIPE SIZES AND GAS PRESSURE REQUIREMENTS, PLEASE REFER TO OPERATION AND INSTALLATION MANUAL.
2. VENTING MATERIALS FOR IQ251 SHOULD BE CPVC, APPROVED POLYPROPYLENE, OR AL29-4C STAINLESS STEEL.
3. ENSURE ALL PIPE DIAMETER ARE SIZED ADEQUATELY TO HANDLE THE FLOW VOLUME (GPM) AT A MAXIMUM WATER VELOCITY OF 6 FEET PER SECOND.
4. PIPE T&P VALVE TO DRAIN WITH NO SHUTOFF VALVES OR RESTRICTIONS IN THE LINE; OR PER LOCAL CODE REQUIREMENTS.
5. ROUTE PIPING FOR T&P, DRAIN VALVE AND CONDENSATE TO FLOOR DRAINS AND SPILL INDIRECTLY. TYPICAL OF ALL WATER HEATERS AND STORAGE TANKS.
6. MOUNT WATER HEATER AND TANK ASSEMBLY LEVEL ON 4" THICK STEEL REINFORCED CONCRETE HOUSE KEEPING PAD. INSTALL IN A MANNER TO MAINTAIN
MANUFACTURERS SUGGESTED CLEARANCES. ROUTE FULL SIZE EXHAUST VENT AND COMBUSTION INTAKE TO EXTERIOR WALL AS SHOWN. PROVIDE SLEEVED WALL
PENETRATION SEALED WEATHER TIGHT.
7. VACUUM RELIEF VALVES ARE SHOWN FOR SCHEMATIC PURPOSES ONLY. THE VACUUM RELIEF VALVE SHALL COMPLY WITH ANSI Z21.22. THE VACUUM RELIEF VALVE
SHALL BE INSTALLED IN THE COLD WATER SUPPLY LINE ABOVE THE TOP OF THE WATER HEATER. REFER TO IPC 2009 504.2
Electrical Supply (typ)
Condensate Drain (typ)
iQ251
(Setpoint 140°F)
ET-1
ET-2
RCP-1
RCP-2
CS-1
CS-2
MV-1
3/4" 140°F HWR
3/4" HWR
2-1/2" CW
1" (2PSI) GAS
G
2" 124°F HW TO SUPPLY
GUEST ROOMS. SEE P-201
FOR CONTINUATION.
1-1/2" 140°F HW TO KITCHEN
AND LAUNDRY EQUIPMENT. SEE
P-201 FOR CONTINUATION
2" HW
2" CW
1-1/2" 140°F HW
2" CW
2" CW
1"
2-1/2" CW2" CW
2" HW 2" HW
1-1/2" HW
1"
3/4" HWR
3/4" HWR
1" (2PSI) GAS
SHUT OFF VALVE WITH LBS-TO-INCHES REGULATOR
2" GAS 2" GAS
1-1/4" GAS 1-1/4" GAS
3/4" GAS
WATER HAMMER
ARRESTOR
LEGEND
PRESSURE RELIEF VALVE
ISOLATION VALVE
CHECK VALVE
COUPLING
PRESSURE REGULATOR
RECIRCULATION PUMP
BALANCING VALVE
TEMPERATURE GUAGE
VALVE
NORMALLY CLOSED
GG
G
SEE VENDOR'S WATER
SOFTENER SCHEMATIC
FOR PIPE ASSSEMBLY
BRINE AND DRAIN LINE
OUT WATER SOFTENER
SYSTEM.
2-1/2" WATER
SOFTENER BYPASS.
N.C.
FIELD COORDINATE BRINE &
RESIN TANK LOCATIONS.
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
DETAILS
P6-01
SCALE: NONE
DOMESTIC WATER BACKFLOW PREVENTER DETAIL
HOT WATER SUPPLY & DRAIN SHALL BE
INSULATED OR COVERED WITH A
REMOVABLE NON METALLIC BAFFLE WHEN
HOT WATER EXCEEDS 120°F.
CONTROLS SHALL MOUNTED ON WIDE
SIDE OF TOILET AREA & OPERATE ON 5
LBS OF FORCE OR LESS.
PRIVACY SCREEN
DASHED LINE DENOTES MAX. SIZE OF
REMOVABLE, NON- METALLIC BAFFLE
SHADED AREA DENOTES KNEE AND TOE
SPACE REQUIRED AT ACCESSIBLE
LAVATORY.
8" MIN.
6" MAX.
9" M
IN
.
44" M
AX.
27" M
IN
.
29" M
IN
.
34" M
IN
.-36" M
AX.
TO
P O
F SEAT
17"-19"
44" M
AX.
C
L
18"
RIM
ELEV
17" AFF
C
L
BOTH SIDES
15" MIN.
TYPICAL FOR FLUSH VALVE
OR TANK TYPE & WALL OR
FLOOR MTD.
TYPICAL FOR WALL OR
CABINET MTD. LAVATORY,
OPERATE ON 5 LBS OF FORCE OR LESS
URINAL SHALL HAVE A MIN.
14" ELONGATED BOWL.
SCALE: NONE
ADA PLUMBING FIXTURE INSTALLATION DETAIL
MAY EXTEND AS
REF. ARCH. DWGS.
FOR WALL CONST.
CLEANOUT TEE
WASTE OR VENT
OF LINE CLEANOUT
1/8" BEND AND END
WASTE LINE
FLOW
NEOPRENE SEAL
CLEANOUT PLUG
SET SCREW
FINISHED FLOOR
HEAVY SCORIATED COVER
CONCRETE
FLOOR SLAB
SET LEVEL WITH FINISHED FLOOR. IN
CARPETED PUBLIC AREAS, MAKE FLUSH
WITH CONCRETE.
4" PIPE
4" LONG SWEEP
4" PIPE
BRASS COUNTERSUNK PLUG
C.I. FERRULE WITH THREADED
& EIGHTH BEND
4" COMBINATION WYE
CLEANOUT INSTALLATION DETAILS
NOTE: SEE SPECS FOR PIPING MATERIAL
EXTERIOR CLEANOUT INSTALLATION DETAIL
WALL CLEANOUT INSTALLATION DETAIL
FLOOR CLEANOUT INSTALLATION DETAIL
FINISHED GRADE
CLEANOUT TO GRADE INSTALLATION DETAIL
BRASS CLEANOUT PLUG
W/ COUNTER SUNK HEAD.
16"SQUARE CONC. PAD
TROWEL SMOOTH AND EDGE.
1/8 C.I. BEND
C.I. WASTE LINE.
LENGTH TO SUIT.
WASTE LINE
1/8 BEND IF CLEANOUT
OCCURS AT END OF LINE.
SCALE: NONE
14"x14"x5"
CONCRETE PAD
18"x14"x5"
CONCRETE PAD 14"x14"x5"
CONCRETE PAD
TWO WAY
CLEANOUT FITTING
LINE SIZE SEE PLAN
PLUG IF END OF LINE
ADJUSTABLE HOUSING
POLISHED S.S.
ACCESS COVER
COUNTERSUNK SCREW
CLEANOUT PLUG
WASTE LINE LENGTH TO SUIT
FLOORDRAIN OR HUBDRAIN
AIR GAP
12" MIN.
30" MAX.
NOTE:
ALL PIPING TO BE RIGIDLY
SUPPORTED FROM WALL.
2" DOM. WATER
REDUCER
DIRECTION OF FLOW
REDUCER
2" DOM. WATER
3" DOM. WATER
FULL PORT BALL
VALVE
IN-LINE BRONZE "Y" TYPE
STRAINER WITH 20 MESH
STAINLESS STEEL SCREEN.
3" DOM. WATER
PRESSURE GAUGE. SELECTED FOR
OPERATING PRESSURE RANGE.
(TYPICAL OF 4)
2" WILKINS MODEL 2-975XL-AG
REDUCED PRESSURE PRINCIPLE
BACKFLOW PREVENTER
SET VALVE 5 PSI HIGHER
WILKINS 500 SERIES
PRESSURE REDUCING VALVE.
SET VALVE 5 PSI HIGHER
2" DOM. WATER
LENGTH AS REQ'D
3/8"∅ THREADED ROD
SUPPORT FROM ROOF JOISTS
3/8"∅ THREADED ROD
(SIZE AS REQ'D)
CLEVIS HANGER
SUPPORT FROM
ROOF JOIST
STEEL CHANNEL
STEEL PIPE STRAP
SADDLE
INSULATION
BOLT & CLAMPING
NUT (TYP)
MULTIPLE PIPE RUNS
SADDLE
SINGLE PIPE RUN
1 5/8"x1 5/8"x12 GA.
INSULATION
SCALE: NONE
PIPING SUPPORT INSTALLATION DETAILS
UNION
GAS BALL VALVE
LINE REGULATOR, 2 PSIG INLET
EQUIPMENT SUPPLY PRESSURE
OUTLET WITH LEAK LIMITER IN
VENT (OR VENT TO
OUTDOOORS AS REQ'D)
8" LONG DIRT LEG WITH
REMOVABLE END PLUG
CONNECTION
TO EQUIPMENT
SCALE: NONE
2 PSI GAS CONNECTION DETAIL
2 PSI GAS LINE
FROM MAIN
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
DETAILS
P6-02
INDIRECT WASTE
DRAIN OR FLOOR
SINK
FLOOR
VENT
TRAP ARM
WASTE
CLUSTER CLOSELY
TOGETHER
AIR GAP PER NSPC
SECTION 9.3.1
SCALE: NONE
INDIRECT WASTE DRAIN DETAIL
SCALE: NONE
ELEVATOR SUMP PUMP DETAIL
FLOW
CIRCULATION
PUMP (RCP-1)
BALANCING
VALVE
AQUASTAT
TEMPERATURE GAUGE
CHECK VALVE
UNION OR FLANGED
TYPE PUMP SERVICING
CONNECTION (TYP.)
NOTE: SUPPORT PUMP FROM
STRUCTURE, WALL, OR
FLOOR AS REQUIRED.
FULL PORT BALL
VALVE (TYP.)
HOT WATER CIRCULATION PUMP
SCALE: NONE
MOTOR
ELEVATOR SHAFT WALL
2" COPPER DISCHARGE
GATE VALVE
CHECK VALVE
SUMP GRATE
ZOELLER 153-002 OIL SENSING
SUMP PUMP. 1/2 HP, 115V/1∅
SUMP PIT
ELEV. SHAFT FLOOR
FINISHED FLOOR
INDIRECT
DISCHARGE TO
MOPSINK .
PIPE SIZE
AS NOTED
ON PLAN
CONCRETE
EXCEPTION OF CLEAR WATER WASTES.
IN LENGTH SHALL BE TRAPPED WITH THE
NOTE: INDIRECT WASTE PIPING EXCEEDING 5'
FLOOR SINK DETAIL
SCALE: NONE
2x INLET PIPE DIA. AIR GAP
FINISHED
FLOOR
INDIRECT
WASTE LINES
INSULATE TO
COPPER C.W. LINE
3/4" INSULATED
HYDRANT
HYDRANT
THIS ELBOW
MASTIC
INSULATING
SECTIONPLAN
SAW BLOCK FOR
EVEN EDGES AT
THESE POINTS
EXPOSED WALL HYDRANT INSTALLATION DETAIL
SCALE: NONE
HO
T
CO
LD
INSTALL CHECK VALVES ON COLD &
HOT WATER SUPPLY TO FAUCET.
INSTALL VALVES IN ACCESSIBLE
LOCATION.
3" DIA. P-TRAP
SPOUT BRACE
METAL EDGE
36"
DRAIN
SPOUT WITH HOSE END
SERVICE FAUCET WITH
AND PAILHOOK
VACUUM BREAKER
10"
SCALE: NONE
MOP SINK INSTALLATION DETAIL
SCALE: NONE
GREASE INTERCEPTOR DETAIL LOW-BOY FLOOR TYPE DETAIL
WASTE
VENTED
GREASE INTERCEPTOR
TO SAN. WASTE MAIN
VALVE
FLOW CONTROL
TRIPLE COMPARTMENT SINK
AIR INTAKE
SANITARY BRANCH RUNOUT FROM
GUESTROOM. 4"∅ PIPING SHALL BE
SLEEVED WITH 8"∅ SCH 40 PVC.
FINISHED SLAB - 0"-0"
BOTTOM OF FOOTER.
SEE STRUCTURAL PLANS.
1'-0" MIN
3'-0" MIN
SCALE: NONE
UNDER SLAB SANITARY INVERT CLARIFICATION DETAIL
TRAP PRIMER DETAIL
NOTE:
LOCATE IN AN ACCESSIBLE
BUT CONCEALED OR
SEMI-CONCEALED LOCATION.
DISTRIBUTION UNIT AS
REQ'D 2 TO 4 OPN'G
BALL VALVE
WATER SUPPLY
12" MIN
TRAP
VALVE
PRIMER
TP-1
CONNECTION TO FLOOR
DRAIN TRAP (TYPICAL)
SCALE: NONE
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num.Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
________________________________________________________________________
BY DATE
05/31/2017
PLUMBING
DETAILS
P6-03
STEEL PIPE THROUGH CONCRETE FLOOR OR WALL
SECTION A-A
TOP VIEW
F RATING = 3-HR.
T RATING = 1/4-HR.
U.L. SYSTEM NO. CAJ1154
NOTES : 1. MAXIMUM DIAMETER OF OPENING IS 14".
2. ANNULAR SPACE 0" TO A MAX. 0F 3-1/4".
3. WALLS REQUIRE 1/2" DEPTH OF FS 605 ON BOTH SIDES.
SEE HILTI FIRESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS
HILTI, INC. TULSA, OK 1-800-879-8000
AA
1
2
3 5
4
1. FLOOR OR WALL ASSEMBLY :
A. MIN. 4-1/2" THICK LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE.
B. MIN. 8" CONCRETE BLOCK.
2. 10" DIA. (OR SMALLER) STEEL PIPE, 4" DIA. EMT, OR 4" DIA.
3. MIN. 1/2" DEPTH HILTI FS 605 FIRESTOP SEALANT.
4. HILTI CF 124 FOAM, BACKER ROD, OR MINERAL WOOL.
5. MIN. 1/2" BEAD OF HILTI FS 605 AT PIPE POINT OF CONTACT.
COPPER PIPE.
NOTES : 1. ANNULAR SPACE = MIN. 1-5/8", MAX. 2-1/2".
2. WALLS REQUIRE SEALANT ON BOTH SIDES.
3. MAXIMUM AREA OF OPENING = 192 SQ. IN. WITH MAX.
DIMENSION OF 24 INCHES.
SEE HILTI FIRESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS
HILTI, INC. TULSA, OK 1-800-879-8000
A
8"
1
4
5
1. FLOOR OR WALL ASSEMBLY :
A. MIN. 4-1/2" THICK CONCRETE FLOOR.
B. MIN. 5" CONCRETE WALL.
C. ANY U.L. CLASSIFIED CONCRETE BLOCK WALL.
2. MAX. 3" DIA. (OR SMALLER) COPPER TUBING, STEEL PIPE, OR EMT CONDUIT.
3. OPTIONAL 1" THICK (OR LESS) GLASS FIBER PIPE INSULATION COVERED
WITH ALL SERVICE JACKET.
4. MIN. 4" DEPTH MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED.
5. MIN. 1/2" DEPTH HILTI FS 601 FIRESTOP SEALANT.
STEEL/COPPER PIPE THROUGH CONCRETE OR
SECTION A-AFRONT VIEW
F RATING = 2-HR.
T RATING = 0 AND 1/4-HR.
U.L. SYSTEM NO. WJ1021
NOTES : 1. ANNULAR SPACE = MIN. 0", MAX. 2-3/4".
2. T RATING = 1/4-HR. WHEN STEEL PIPE IS USED.
SEE HILTI FIRESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS
HILTI, INC. TULSA, OK 1-800-879-8000
A
A
1
2
3
4
5
6
1. WALL ASSEMBLY :
A. MINIMUM 5" THICK CONCRETE WALL.
B. ANY U.L. CLASSIFIED CONCRETE BLOCK WALL.
2. 17-1/4" DIA. (OR SMALLER) STEEL PIPE OR 4" DIA. (OR SMALLER)
COPPER PIPE.
3. NO. 8 STEEL WIRE MESH RECESSED 1/8" BELOW EACH WALL SURFACE (FOR
HOLLOW BLOCK WALLS ONLY).
4. MINIMUM 4-1/2" THICKNESS FLEXIBLE URETHANE SHEET, (MIN. 4 PCF DENSITY).
5. MINIMUM 1/4" DEPTH HILTI FS 605 FIRESTOP SEALANT.
6. 1/2" BEAD HILTI FS 605 SEALANT AT POINT OF CONTACT.
CONCRETE BLOCK WALL
NOTES : 1. MAXIMUM DIAMETER OF OPENING = 18".
2. ANNULAR SPACE = MIN. 1", MAX. 1-1/8".
3. FOR CONCRETE WALLS USE EITHER 1/4" HILTI KWIK BOLT II
OR X-ZF 27 PINS WITH STEEL WASHER. FOR CONCRETE BLOCK
WALLS USE HILTI SLEEVE ANCHORS.
SEE HILTI FIRESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS
HILTI, INC. TULSA, OK 1-800-879-8000
A
2
5
6 71. WALL ASSEMBLY :
A. MINIMUM 5" THICK CONCRETE WALL.
B. ANY U.L. CLASSIFIED CONCRETE BLOCK WALL.
2. 10" DIA. (OR SMALLER) STEEL PIPE, 0R 4" DIA. (OR SMALLER)
EMT OR COPPER PIPE.
3. MAXIMUM 2" THICK (MIN. 3.5 PCF) GLASS FIBER INSULATION.
4. OPTIONAL: STEEL SLEEVE (SCHEDULE 40 OR HEAVIER) CAST OR
SECURELY GROUTED INTO WALL.
5. HILTI RETAINING COLLAR FILLED COMPLETELY WITH HILTI FS 611A.
6. ATTACH EVERY OTHER TAB WITH APPROPRIATE HILTI FASTENERS
(SEE NOTE 3).
7. HILTI COLLAR CLAMP(S).
8. MINIMUM 1-1/4" DEPTH HILTI FS 611A FIRESTOP SEALANT.
NOTE : NOMINAL ANNULAR SPACE OF 1/4" TO 1" REQUIRED.
SEE HILTI FIRESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS
HILTI, INC. TULSA, OK 1-800-879-8000
A
A
2
1
3
1. 1-HR. FIRE-RATED GYPSUM WALL ASSEMBLY.
2. 10" DIA. (OR SMALLER) STEEL PIPE, 4" DIA. (OR SMALLER)
COPPER PIPE, EMT OR CONDUIT.
3. MIN. 5/8" DEPTH HILTI FS 601.
SECTION A-A
FRONT VIEW
HILTI, INC. TULSA, OK 1-800-879-8000
SEE HILTI FIRESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS
NOTES : 1. MAXIMUM DIAMETER OF OPENING IS 18".
2. NOMINAL ANNULAR SPACE OF 1-1/8" IS REQUIRED.
U.L. SYSTEM NO. WL5023
F RATING = 1-HR.
T RATING = 3/4-HR.
FRONT VIEW
SECTION A-A
INSULATED STEEL PIPE THROUGH 1-HR. GYPSUM WALL
A
A
1
2
3
4
5 6
7
8
1. 1-HR. FIRE-RATED GYPSUM WALL ASSEMBLY.
2. OPTIONAL : 18" DIA. (OR SMALLER) SCHEDULE 40 STEEL SLEEVE.
3. 10" DIA. (OR SMALLER) STEEL PIPE OR 4" DIA. (OR SMALLER)
COPPER PIPE, EMT OR CONDUIT.
4. NOMINAL 2" THICK (MIN. 3.5 PCF) GLASS FIBER INSULATION WITH
AN ALL SERVICE JACKET.
5. HILTI RETAINING COLLAR. COMPLETELY FILLED WITH MIN. 2" DEPTH
6. MIN. 5/8" DEPTH HILTI FS 611A INSIDE ANNULAR SPACE.
7. RETAINING COLLAR CLAMP(S).
8. 1/4" HILTI TOGGLER BOLTS TO FASTEN EVERY OTHER TAB.
HILTI FS 611A FIRESTOP SEALANT.
EMERGENCY SHOWER/EYE-WASH INSTALLATION DETAIL
SCALE: NONE
+
45"
1-1/4" VENT LINE
2" SAN
4" SAN
(TYPICAL)
1/2" TRAP PRIMER CONNECTION
THERMOSTATIC MIXING VALVE
CABINET AS PER SPECIFICATION
1 1/4" CHROME OR
STAINLESS STEEL
4" SLEEVE & FIRE STOP
PIPES
CEILING LINE
3/4" HW & 3/4" CW
FD-1
FLOOR LINE
5'-0"
2/1/2017 5:14:29 P
M
El P
aso
, T
exa
s
TR
U b
y H
ilto
n - E
l P
as
o
Tru
H
ote
l P
artn
ers, L
LC
16105
Revision Schedule
Rev.
Num. Rev. Date Revision Description
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.001-17
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
Release Date:
Project No.:
SCALE: NONE
LAUNDRY TRENCH DRAIN DETAIL
7'-6"
1'-0"
C0NCRETE TRENCH
S.S. MESH
FILTER
FLOOR DRAIN IN BTM.
OF TRENCH - ZURN #Z-585
S.S. MOUNTING
CHANNEL (EACH)
SIDE OF TRENCH
1/4" X 1/4" STAINLESS STEEL MESH
IN S.S. FRAME (FREE SLIDING)
HINGED GRATE
SLOPE TO DRAIN
FORMED CONCRETE TRENCH
FLOOR
SEDIMENT
BUCKET
DEEP SEAL, CAST
IRON P-TRAP
9"
________________________________________________________________________