2017Version 1.0
Plumbers’Handbook
®
®
®
22
To receive updates of the Rheem Plumbers’ Handbook
register at
rheem.com.au/trade-promotions
How to Download a QR Code Reader to your Mobile Device
Open your mobile app store (App Store, Google Play, Windows Marketplace, etc.)
Search for QR code reader. Check out the list of QR code readers for mobile phones to find the right one for you.
Simply download the QR code reader to your phone, open it and you are ready to scan the codes that appear in the Rheem Plumbers’ Handbook .
3
Contents
Installation - Checklist
General 4
Electric Water Heaters/Heat Pump 5
Gas Water Heaters 6
Solar Water Heaters 7
Hot Water Recirculation Systems 8
Anode Selection & Water Supplies 9
Water Connections 11
Pipework and Pipe Sizing 14
Specific Applications 15
Electric Storage Models 17
Gas Storage Models 45
Gas Continuous Flow Models & Accessories 65
Solar Models 91
Heat Pump Models 111
4
Water Heater position
Read the Installation Instructions, to familiarise yourself with the unit – the water heater must be installed, operated and maintained in accordance with the Owner’s Guide & Installation Instructions and local state regulations.
Water heaters must be installed and serviced by a qualified person.
Keep the tank vertical at all times during transport and installation. Not applicable to solar thermosiphon tanks or Stainless Steel water heaters.
Locate close to point of use or the most frequently used hot water outlet:
Closer to the most often used tap will help reduce running costs.
Minimising the length of hot water pipework reduces the time taken for hot water to reach the tap, heat loss and water wastage.
Leave headroom of approximately one water heater height to allow anode inspection and replacement (storage water heaters and hot water storage tanks). Not applicable to Stainless Steel water heaters.
Ensure controls can be easily operated.
Ensure serviceable parts such as TPR (temperature pressure relief) valve are accessible.
Ensure rating label/data plate can be easily read.
Ensure service access covers are easily removable.
For OUTDOOR storage water heaters:
Must be installed on a level plinth 50mm above surrounding ground. Gas storage units must be installed up against a wall or rigid vertical support via the brackets provided.
DO NOT place in direct contact with concrete that is less than 2 months old and not fully cured as this may attack the metal coating of the jacket. A moisture barrier between the two surfaces should be used in this instance.
Installation Checklist General
5
Installation Checklist Electric Water Heaters/Heat Pump
Location
Water heaters installed in roof spaces – local authorities have regulations regarding such installations, so check with your local authorities.
Ensure the front covers, thermostats and elements can be removed for service.
Installation Standards & Safety
The water heater is supplied with a thermostat and a over-temperature cut-out and a combination temperature pressure relief valve (TPR). These devices MUST NOT be tampered with or removed, except for authorised service. The water heater must not be operated unless each of these devices is fitted and in working order.
Operation of the over-temperature cut-out indicates a possibly dangerous situation. Only reset the control after the cause of its operation has been determined and any fault corrected.
The water heater must be installed
By a qualified person
In accordance with the Installation Instructions and in compliance with Standards AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulations.
Safe Tray
Where property damage could occur in the event of a leak, the water heater must be installed in a safe tray
Safe tray construction, installation and draining must comply with AS/NZS 3500.4 and local codes/regulations; check all relevant requirements before installing.
6
A flue of up to 150mm internal diameter must be 25mm clear of combustible materials such as timber walls and cupboards.
A flue exceeding 150mm internal diameter requires clearances of 75mm from unprotected surfaces and 50mm from protected surfaces.
Outdoor gas water heaters (all types) must have minimum clearances from the flue terminal to certain building features such as openable windows/doors and to fences/walls. Refer to AS/NZS 5601.1 for these clearances.
Leave clearance to allow removal of the burner assembly if required.
Leave adequate clearance on all sides for ventilation and safety and ensure flue terminal and air inlet are free from any obstruction (Gas storage and Continuous Flow).
Ensure the combustion air supply is not likely to be contaminated with substances that are corrosive or would become corrosive after passing through a flame.
Outdoor storage models must be installed against a wall or rigid vertical support.
Outdoor models must have free and balanced airflow at both the air intake and flue outlet.
Indoor water heaters require correct ventilation - check AS/NZS 5601.1 for requirements
Gas Continuous Flow
The high gas consumption of these water heaters often necessitates larger diameter gas supply pipe. Undersized pipe will affect performance and hot water capacity. Size the gas supply pipe using the MJ rating marked on the appliance.
Large capacity (27L/minute) Continuous Flow water heaters may, due to their gas consumption, require greater clearance distance from doors and windows – check AS/NZS 5601.1 requirements.
Installation Checklist Gas Water Heaters
7
The correct type of solar water heater is to be selected for the area. Consideration must be given to whether freeze protection is required and to the chemistry of the water to be supplied to the water heater.
For a split system, consideration must also be given to the position of the collectors in relation to the solar storage tank. There are limitations on both the maximum length of the solar hot and solar cold pipes and the maximum height between the storage tank and the collectors. Refer to the installation instructions supplied with the product.
The collectors must be installed in a shade free position. The surrounds should be checked for higher buildings or trees which may cause shade at other times of the year and for small trees which may grow and shade collectors in the future.
The installation must comply with the requirements of either AS/NZS 3500.4 or AS/NZS 3500.5:2012 Section 3 (for a Class 1a or Class 10 building) as applicable under the Plumbing Code of Australia, and all local codes and regulatory authority requirements.
The installer must ensure the structural integrity of the building is not compromised by the solar water heater installation and the roof structure is suitable to carry the full weight of the collectors and frame (if one is installed). If in any doubt of the construction or the condition of the roof, the roof should be suitably strengthened. Consult a structural engineer.
Maximum performance is achieved with an orientation facing true north. Always check for true north using a compass or other suitable device.
The performance of a system reduces as the orientation of the collectors moves away from true north, resulting in the need for increased boosting to supply the same hot water load.
Where it is not possible or practical to install collectors facing north, they may be oriented up to 90° from north (subject to installation code requirements). It may be desirable to install an additional collector or higher performance collectors to help make up for the reduction in solar performance. Each option should be discussed with the system owner. If neither of these options is possible or acceptable to the system owner, then the system owner needs to be made aware of, understand and accept that increased boosting may be required to meet their hot water requirements.
Frames are available from Rheem to raise the inclination of the collectors, and for high wind (cyclone) areas.
Installation Checklist Solar Water Heaters
8
When water heaters are installed on a hot water flow and return recirculation system, the following should be included:
A suitable pump correctly aligned, oriented and weather protected with a check valve and isolation valves.
To reduce energy costs a timer to activate circulation in periods of regular demand.
Suitable pipe insulation to minimise heat loss.
A Temperature Limiting Device positioned on individual branch lines to ablution areas, not in the main flow line to the building.
Where multiple water heater are manifolded, correct Equa-flow® principles must be followed.
Installation Checklist Hot Water Recirculation Systems
9
Every Rheem water heater is manufactured to suit the water conditions of most public reticulated water supplies, but some water chemistries can have detrimental effects on the water heater’s operation and life expectancy.
Ask the local Water Supply Authority for information on the water chemistry, which you can check against the Rheem guidelines below.
A water heater cylinder or heat exchanger can be affected by the chemistry of the water supply. The cylinder of the water heater is only covered by Rheem warranty when the total dissolved solids (TDS) in the water supply is below 2500mg/L and the correct colour anode is used. Using the wrong coloured anode may also shorten the life of the cylinder.
Use the following table to select the correct colour anode to be fitted:
Total Dissolved Solids Anode colour code
0 - 40 mg/L Green
40 - 150 mg/L Green or Black
150 - 400 mg/L Black
400 - 600 mg/L Black or Blue
600 - 2500 mg/L Blue
2500 mg/L + Blue (no cylinder warranty)
The anode will slowly dissipate over time while protecting the cylinder. The life of the cylinder may be extended by replacing the anode.
If the anode is not replaced at the 5 year service, the maximum time when it should be replaced is not more than 8-10 years (depending upon the model – refer to the Owner’s Guide & Installation Instructions).
For water supplies that are softened, desalinated or where the water supply may alternate between tank water and reticulated public supply or another supply, it is recommended the anode be replaced within 5 years of installation and every 5 years thereafter.
Saturation Index is a measure of the water’s corrosive or scaling properties. A corrosive water supply can attack copper components. Where the saturation index is less than -1.0:
Water is very corrosive
A corrosion resistant element must be used for the Rheem warranty to cover the element
Anode Selection & Water Supplies
10
Anode Selection & Water Supplies - cont’d
In a scaling water supply calcium carbonate is deposited onto any hot metallic surface.
Where the saturation index exceeds +0.4:
Water is very scaling
An expansion control valve must be fitted on the cold water line after the non-return valve for the Rheem warranty to cover the cylinder and TPR valve
Where the saturation index exceeds +0.8:
Rheem warranty does not cover a standard watts density element
A low watts density element must be used for the Rheem warranty to cover the element
Stainless Steel cylinders are not suitable for installation in some areas, where water chemistry is such that the cylinder can be affected. Installation in these areas may void the cylinder warranty.
Before installing, check the Rheem website for suitable installation areas: www.rheem.com.au/stellar
+0.4 +0.80
very corrosive very scalingscalingcorrosive
-1.0
SATURATION INDEX (SI)WATER HEATERS
WITHIN WARRANTYSPECIFICATION
SATURATION INDEX(calculated @ 80°C water temperature)
no w
arra
nty
appl
ies
to a
: te
mpe
ratu
re p
ress
ure
relie
f val
ve o
r aw
ater
hea
ter c
ylin
der u
nles
s an
expa
nsio
n co
ntro
l val
ve is
fitte
d.
no w
arra
nty
appl
ies
to a
:- s
tand
ard
wat
ts d
ensi
ty e
lem
ent
- dire
ct (o
pen
circ
uit)
sola
r col
lect
or- h
eat p
ump
heat
exc
hang
er- s
tain
less
ste
el c
ylin
der
- con
tinuo
us fl
ow c
oppe
r hea
t exc
hang
er
no w
arra
nty
appl
ies
to a
:- s
tand
ard
wat
ts d
ensi
ty e
lem
ent
- dire
ct (o
pen
circ
uit)
sola
r col
lect
or- h
eat p
ump
heat
exc
hang
er- s
tain
less
ste
el c
ylin
der
- con
tinuo
us fl
ow c
oppe
r hea
t exc
hang
er
11
Water Connections
Cold Water Connection191025
The following may be required on the cold water inlet pipework (see figure below for order of installation)Isolating Valve Also known as a stop cock
Required for service and maintenance
Non-Return Valve Also known as a check valveSoft seat type preferredLocated between stop cock and water heaterDo not fit to inlet of continuous flow water heater
Duo Valve Combination isolating and non return valveCan be used instead of two separate valves
Pressure Limiting or Pressure Reducing Valve
Required if supply pressure is likely to exceed 80% of relief valve setting.Recommended use on supply to the entire building to ensure same pressure of cold and hot water
Expansion Control Valve Required for all storage water heaters in QLD, WA, SA and any other area where the water supply has a saturation index exceeding +0.4Last valve before water heater
Disconnecting Union Final fitting on the cold water plumbing.
Expansion ControlValve
Pressure LimitingValve
Non-ReturnValve
Stopcock
To UnionConnector
12
Hot Water Connection191025
The following are required for the hot water outletTemperature Limiting Device/Tempering Valve/ Thermostatic mixing valve
Required for bathrooms, basins, not required for kitchen, laundry
Pipe Insulation The pipe work must be insulated in accordance with AS/NZS 3500.4All piping with circulating water is to be insulated
Disconnecting union First fitting after the water heater.Note: Vacuum break valves are not normally necessary. Note: Heat traps are only required on Rheem Stainless Steel top outlet water heaters. (Dip tube on other Rheem models acts as an integral heat trap).In Western Australia heat traps are required on all electric storage water heaters.
Water connections - cont’d
Control of Delivery Temperature
AS/NZS 3500.4 stipulates a maximum of up to 50oC hot water temperature to ablution areas (bathrooms). This may be reduced to 45oC depending on the building’s use. This is mandatory for all new installations. The above requirement is mandatory in some states for replacement installation also. Check local regulatory requirements in your area for new and replacement installations.
This is achievable via:
For 50°C applications – tempering valve, thermostatic mixing valve or an AS 3498 compliant 50OC limited water heater model eg: Rheem Gas Continuous Flow model, RheemPlus Heat Pump, RheemPlus Gas or Electric storage
For 45°C applications – thermostatic mixing valve
13
Water Connections
TPR and ECV Drain Line191025
The relief valve must be fitted with a drain pipe, with the following requirements:
The minimum diameter of the pipe is DN15 on 15 mm valves, and DN20 on 20 mm valves.
The drain pipe must be of copper.
The drain pipe must be of minimum possible length and have a continuous fall to its outlet.
Where the distance from the valve to the final point of discharge is greater than 9 m, the valve drain line must discharge into a tundish that is drained in accordance with AS/NZS 3500.4
Relief Valve drains must terminate in a position that is visible, will not cause nuisance or damage and will not cause injury. Local regulations may require that the discharge from relief valves terminate to a drain.
In frost prone areas additional requirements apply, refer to AS/NZS 3500.4
14
Pipework and Pipe Sizing
Pipe material
All pipe material used must comply with the requirements of AS/NZS 3500.4.
Plastic/synthetic pipe:
Cannot be used for the last metre into and first metre out of the water heater – these sections must be copper.
Must be rated to the same maximum working pressure and temperature the water heater is capable of supplying.
MUST NOT be used for solar flow and return installations.
Pipe Sizing
Calculating the correct pipe diameter for the installation involves 3 steps:
1. Estimate the peak required flow rate along the length of the pipe.
Note: if the home is fitted with water saving fixtures the required flow rate will be reduced.
2. Calculate the pressure gradient along the pipe.
3. Refer to the pipe supplier’s product handbook to determine the recommended pipe diameter
For most domestic installations, it is acceptable to base pipe sizing for hot water reticulation on known average requirements.
ApplicationFlow Rate (Hot Water)
Litres/min Litres/sec
Domestic Bath 18 0.3Domestic Shower 6 0.1Hand Basin 6 0.1Kitchen Sink and Laundry Tub 7 0.12Washing Machines and Dishwashers 12 0.2
15
Specific Applications
Rheem water heaters (other than Commercial specific models such as Commpak or Heavy Duty models) are designed for use in a single family domestic dwelling for the purpose of heating potable water. Use in any other application may shorten the life of the water heater.
If an uninterrupted hot water supply is necessary for the application or business, there should be back-up redundancy built into the system design, to ensure supply continuity in the event of the water heater becoming inoperable. We recommend you provide advice to the system owner regarding their needs and building back-up redundancy into the hot water supply system.
Scan code for details & installation
instructions
Water connections
Electric S
torag
e
17
18
19
Scan code for details & installation
instructions
Rheem Electric 25L 191025,191025/P
Features & Benefits
Small diameter - 400mm
Fast, easy like-for-like replacement
Dual handed connections
Plug & lead indoor models 2.4kW only
7 year cylinder warranty1
MODEL 191025191025/P
Hot Water Delivery (L) 25kW Rating 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP3/4
Approx. Weight (Empty) kg 19
7YEARW
AR R A N
TY
C
YLINDER
436430
60
106
142
400
64O 64O
26O 26O
PEOPLE INSTALLATION
1Indoor/Outdoor
20
Scan code for details & installation
instructions
Rheem Electric Compact 25 111025,111025/P
Features & Benefits
The smallest Rheem electric water heater
Small diameter - 385mm
Fast, easy like-for-like replacement
Plug & lead indoor models 2.4kW only
7 year cylinder warranty1
MODEL 111025111025/P
Hot Water Delivery (L) 18kW Rating 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Approx. Weight (Empty) kg 18
7YEARW
AR R A N
TY
C
YLINDER
385
420
65O
26O
390
60
130
116
Indoor/Outdoor
PEOPLE INSTALLATION
1
21
Scan code for details & installation
instructions
Rheem Electric Compact 47 191045
MODEL 191045Hot Water Delivery (L) 47kW Rating 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Approx. Weight (Empty) kg 25
7YEARW
AR R A N
TY
C
YLINDER
Features & Benefits
The most compact available in the over-40L capacity range
Smallest Diameter – 400mm
Just 670mm HIGH (including anode cap)
47L delivery*
Available in 3.6kW rating only
Recessed plug fittings
Dual handed – easier to install
7 year cylinder warranty1
670347
400HOT WATEROUTLET
COLDWATEROUTLET
T&PRVALVE
60142
436
59O
59O
26O 26O
*Rated Hot Water Delivery (L) is 40L in accordance with AS/NZS4692.1. Actual delivery is 47L when tested to AS/NZS4692.1.
PEOPLE INSTALLATION
Indoor/Outdoor1
22
Scan code for details & installation
instructions
Rheem Electric 50L 191050,191050/P
MODEL 191050191050/P
Hot Water Delivery (L) 50kW Rating 1.8, 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Approx. Weight (Empty) kg 26
7YEARW
AR R A N
TY
C
YLINDER
Features & Benefits
Small diameter - 400mm
Designed for restricted space installations
Dual handed connections
Plug & lead models 2.4kW only
Recessed plug fittings
Safe for wall mounting - Wall mounting bracket 299120
7 year cylinder warranty1
60
400
INLET INLET
OUTLET
695397
142
436
59o 59o
26o 26o
Indoor/Outdoor
PEOPLE INSTALLATION
1
23
Scan code for details & installation
instructions
Rheem Electric 80L 191080
MODEL 191080Hot Water Delivery (L) 80kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:with ECV (kPa) 960without ECV (kPa) 1120Water Connections RP 3/4
Approx. Weight (Empty) kg 36
CABLEENTRY
INLET66
480
INLET
OUTLET OUTLET
RELIEFVALVE
945702
64
515
60o60o
24o 24o
7YEARW
AR R A N
TY
C
YLINDER
Features & Benefits
Small diameter - 480mm
Fast, easy like-for-like replacement
Designed for restricted space installations
Dual handed connections
Recessed plug fittings
Australian made
7 year cylinder warranty1
Indoor/Outdoor
PEOPLE INSTALLATION
1 - 2
24
Scan code for details & installation
instructions
Rheem Electric 125L 191125
MODEL 191125Hot Water Delivery (L) 125kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP3/4
Approx. Weight (Empty) kg 49
7YEARW
AR R A N
TY
C
YLINDER
Features & Benefits
Small diameter - 480mm
Fast, easy like-for-like replacement
Designed for restricted space installations
Dual handed connections
Recessed plug fittings
Australian made
7 year cylinder warranty1
CABLEENTRY
INLET66
480
INLET
OUTLET OUTLET
RELIEFVALVE
1340
1102
64
515
60o60o
24o24o
PEOPLE INSTALLATION
Indoor/Outdoor2 - 3
25
Scan code for details & installation
instructions
Rheem Electric 160L 191160, 192160
Features & Benefits
Fast, easy like-for-like replacement
Dual handed inlet and outlet fittings
Twin element model - 192160
All models suit connection to concessional (off-peak) tariffs
Mains pressure water delivery
Australian made
7 year cylinder warranty1
MODEL 191160192160
Hot Water Delivery (L) 160kW Rating 1.8, 2.4, 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Approx. Weight (Empty) kg 55
1610
1332
104 66
HOT WATEROUTLET
COLDWATEROUTLET
T&PRVALVE
1081
480
515
58o58o
23o
7YEARW
AR R A N
TY
C
YLINDER
PEOPLE INSTALLATION
Indoor/Outdoor2 - 4
26
Scan code for details & installation
instructions
Rheem Electric 250L 491250,492250
MODEL 491250492250
Hot Water Delivery (L) 250kW Rating 1.8, 3.6, 4.8 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 76
Features & Benefits
Easy retrofit
Dual handed inlet and outlet fittings
Commercial grade enamel
Thicker sacrificial anode
Twin element model - 492250
Australian made
10 year cylinder warranty1
OUTLET OUTLET
1395
9881117
73
CABLEENTRYINLET INLET
103
640
680
92O
88O
32O
RELIEFVALVE
Indoor/Outdoor3 - 5
PEOPLE INSTALLATION
27
Scan code for details & installation
instructions
Rheem Electric 315L 491315,492315
MODEL 491315492315
Hot Water Delivery (L) 315kW Rating available 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 97
Features & Benefits
Easy retrofit
Dual handed inlet and outlet fittings
Commercial grade enamel
Thicker sacrificial anode
Twin element model - 492315
Australian made
10 year cylinder warranty1
OUTLET OUTLET
1640
1317
113 103
CABLEENTRY INLETINLET
640
680
92O
88O
32O
RELIEFVALVE
1228
Indoor/Outdoor
PEOPLE INSTALLATION
4 - 6
28
Scan code for details & installation
instructions
Rheem Electric 400L 491400,492400
MODEL 491400492400
Hot Water Delivery (L) 400kW Rating 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 118
Features & Benefits
Easy retrofit
Dual handed inlet and outlet fittings
Commercial grade enamel
Thicker sacrificial anode
Twin element model - 492400
Australian made
10 year cylinder warranty1
18401479
1323
105121
690
730
97°83°
30°
OUTLET OUTLETRELIEFVALVE
INLETCABLEENTRY
INLET
Indoor/Outdoor
PEOPLE INSTALLATION
5 - 9
29
Scan code for details & installation
instructions
RheemPlus® Electric 125L 121125
Features & Benefits
Fast, easy like-for-like replacement
50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4
Left hand connection
Australian made
7 year cylinder warranty1
MODEL 121125Hot Water Delivery (L) 125kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections G 3/4BApprox. Weight (Empty) kg 49
7YEARW
AR R A N
TY
C
YLINDER
13401102
64 84
HOT WATEROUTLET
COLDWATEROUTLET
T&PRVALVE
515
183
23o
58o
480545
Indoor/Outdoor
PEOPLE INSTALLATION
2 - 3
30
Scan code for details & installation
instructions
RheemPlus® Electric 160L 121160
Features & Benefits
Fast, easy like-for-like replacement
50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4
Left hand connection
Australian made
7 year cylinder warranty1
MODEL 121160Hot Water Delivery (L) 160kW Rating 3.6Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections G 3/4BApprox. Weight (Empty) kg 57
7YEARW
AR R A N
TY
C
YLINDER
1332
104
1610
HOT WATEROUTLET
COLDWATEROUTLET
T&PRVALVE
84
515
183
23o
58o
480545
Indoor/Outdoor
PEOPLE INSTALLATION
2 - 4
31
Scan code for details & installation
instructions
RheemPlus® Electric 250L 121250
Features & Benefits
Fast, easy like-for-like replacement
50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4
Left hand connection
Australian made
7 year cylinder warranty1
MODEL 121250Hot Water Delivery (L) 250kW Rating 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections G 3/4BApprox. Weight (Empty) kg 74
7YEARW
AR R A N
TY
C
YLINDER
1117
73 128
1395
705
640
262
680
HOT WATEROUTLET
COLDWATEROUTLET
T&PRVALVE
32o
88o
Indoor/Outdoor3 - 5
PEOPLE INSTALLATION
32
Scan code for details & installation
instructions
RheemPlus® Electric 315L 121315
Features & Benefits
Fast, easy like-for-like replacement
50°C temperature limited model supplies hot water at a maximum 50°C in accordance with AS/NZS 3500.4
Left hand connection
Australian made
7 year cylinder warranty1
MODEL 121315Hot Water Delivery (L) 315kW Rating 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections G 3/4BApprox. Weight (Empty) kg 99
7YEARW
AR R A N
TY
C
YLINDER
1317
113
1640705
640
262
680
HOT WATEROUTLET
COLDWATEROUTLET
T&PRVALVE
128
32o
88o
Indoor/Outdoor
PEOPLE INSTALLATION
4 - 6
33
Scan code for details & installation
instructions
Rheem Electric Stellar® SS 50L 4A1050
Features & Benefits
Compact design to fit into cupboards and under bench
Stainless steel cylinder and water fittings resist corrosion for longer, extending product life
Dual handed fittings located on the front of the water heater
4.8% better performance than MEPS reduces energy use, saving money
Up to 42% lighter2 - for easier handling and installation
Australian made
10 year cylinder warranty1
MODEL 4A1050Hot Water Delivery (L) 50kW Rating 1.8, 2.4, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP3/4
Approx. Weight (Empty) kg 17
60o 60o
27.5o 27.5o
HOT WATEROUTLET (LH)
695385
400
432
145
COLDWATERINLET (LH)
TPR VALVE
POWER LEAD & PLUG(APPLICABLEMODELS ONLY)
Indoor/Outdoor
PEOPLE INSTALLATION
1
34
Scan code for details & installation
instructions
Rheem Electric Stellar® SS 80L 4A1080
MODEL 4A1080Hot Water Delivery (L) 80kW Rating 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP3/4
Approx. Weight (Empty) kg 25
Features & Benefits
Stainless steel cylinder and water fittings resist corrosion for longer, extending product life
Dual handed fittings located on the front of the water heater
24% better performance than MEPS reduces energy use, saving money
Up to 42% lighter2 - for easier handling and installation
Australian made
10 year cylinder warranty1
495
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
COLDWATERINLET CABLE
ENTRY
885510
185 110
500
125o
55o
25o
Indoor/Outdoor
PEOPLE INSTALLATION
1 - 2
35
Scan code for details & installation
instructions
Rheem Electric Stellar® SS 125L 4A1125
MODEL 4A1125Hot Water Delivery (L) 125kW Rating 1.8, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Approx. Weight (Empty) kg 30
Features & Benefits
Stainless steel cylinder and water fittings resist corrosion for longer, extending product life
Dual handed fittings located on the front of the water heater
17% better performance than MEPS reduces energy use, saving money
Up to 42% lighter2 - for easier handling and installation
Australian made
10 year cylinder warranty1
495
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
COLDWATERINLET CABLE
ENTRY
1295920
185110
500
125o
55o
25o
Indoor/Outdoor
PEOPLE INSTALLATION
2 - 3
36
Scan code for details & installation
instructions
Rheem Electric Stellar® SS 160L 4A1160
MODEL 4A1160Hot Water Delivery (L) 160kW Rating 2.4, 3.6 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Approx. Weight (Empty) kg 40
Features & Benefits
Stainless steel cylinder and water fittings resist corrosion for longer, extending product life
Dual handed fittings located on the front of the water heater
12% better performance than MEPS reduces energy use, saving money
Up to 42% lighter2 - for easier handling and installation
Australian made
10 year cylinder warranty1
495
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
COLDWATERINLET CABLE
ENTRY
16151240
185110
500
125o
55o
25o
Indoor/Outdoor
PEOPLE INSTALLATION
2 - 4
37
Scan code for details & installation
instructions
Rheem Electric Stellar® SS 250L 4A1250, 4A2250
MODEL 4A12504A2250
Hot Water Delivery (L) 250kW Rating 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:with ECV (kPa) 680without ECV (kPa) 800Water Connections RP 3/4
Approx. Weight (Empty) kg 45
Features & Benefits
Stainless steel cylinder and water fittings resist corrosion for longer, extending product life
Dual handed fittings located on the front of the water heater
Twin element model- 4A2250
19% better performance than MEPS reduces energy use, saving money
Up to 42% lighter2 - for easier handling and installation
Australian made
10 year cylinder warranty1
625
COLDWATERINLET
CABLEENTRY 145
630
120o
60o
30o
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
1440
990
230
Indoor/Outdoor3 - 5
PEOPLE INSTALLATION
Indoor/Outdoor3 - 5
PEOPLE INSTALLATION
38
Scan code for details & installation
instructions
Rheem Electric Stellar® SS 315L 4A1315, 4A2315
MODEL 4A13154A2315
Hot Water Delivery (L) 315kW Rating 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 55
625
COLDWATERINLET
CABLEENTRY 145
630
120o
60o
30o
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
1760
1310
230
Features & Benefits
Stainless steel cylinder and water fittings resist corrosion for longer, extending product life
Dual handed fittings located on the front of the water heater
Twin element model- 4A2315
17% better performance than MEPS reduces energy use, saving money
Up to 42% lighter2 - for easier handling and installation
Australian made
10 year cylinder warranty1
Indoor/Outdoor
PEOPLE INSTALLATION
4 - 6
39
Scan code for details & installation
instructions
Rheem Electric Heavy Duty 50L 613050
MODEL 613050Hot Water Delivery (L) 50kW Rating (3 elements) 3.6, 4.8Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP1 1/4Approx. Weight (Empty) kg 34
Features & Benefits
Ideal for cafés, hair salons and small business applications
Larger mass anode
Quick recovery
5 year commercial warranty on cylinder1
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
675405
440
480
30O
90O
90 80
*First hour delivery calculated @ 50oC rise
Indoor/Outdoor
INSTALLATIONFIRST HR DEL
235 -295*
40
Scan code for details & installation
instructions
Rheem Electric Heavy Duty 315L 613315
MODEL 613315Hot Water Delivery (L) 315kW Rating (3 elements) 3.6, 4.8, 6.0Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP1 1/4Approx. Weight (Empty) kg 100
Features & Benefits
Ideal for cafés, hair salons and small business applications
3 element model
Larger mass anode
Quick recovery
5 year commercial warranty on cylinder1
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
16401294
128 130
Ø640
680
90O
32O
*First hour delivery calculated @ 50oC rise
Indoor/Outdoor
INSTALLATIONFIRST HR DEL
500 -625*
41
Scan code for details & installation
instructions
Rheem Electric Heavy Duty 315L 616315
MODEL 616315Hot Water Delivery (L) 315kW Rating (6 elements) 3.6, 4.8, 6.0Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP1 1/4Approx. Weight (Empty) kg 104
Features & Benefits
Ideal for cafés, hair salons and industrial applications
6 element model
Larger mass anode
Quick recovery
5 year commercial warranty on cylinder1
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
16401294
128 130
Ø640
680
90O
32O
*First hour delivery calculated @ 50oC rise
Indoor/Outdoor
INSTALLATIONFIRST HR DEL
685 -935*
42
MODEL 299120
For suitable for Rheem models 191025, 111025, 191045, 4A1050, 191050, 4A1080, 191080
Rheem Wall Mounting Bracket 299120
Features & Benefits
Suitable for 25L, 50L & 80L
To be only used on walls that can support the load of a filled water heater
For fixing to wood use Tek screws for fixing to concrete, brick masonry and natural stone use DynaboltsTM with 8mm masonry drill (nominal embedment 32mm). DynaboltsTM are not suitable for fixing to mortar or soft masonry (not included)
152
117 8
29 95
17 17
152
14089
13 152
130
110
57
8 8
13
9517 17
25
1010o
127
186
5
152
89
13127
Slotted Top Plate
Offset Plate
Bottom Angle Support
Indoor/Outdoor
INSTALLATION
43
Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product
warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater
models of the same capacity.
44
Scan code for details & installation
instructions
Gas S
torag
e
45
47
Scan code for details & installation
instructions
Rheem Gas Internal 135L 300135
Features & Benefits
Suitable for indoor installations
Mains pressure – to service multiple hot water demand at once
An easy replacement for most existing 3 Star models
Natural and propane gas model
Australian made
5 year cylinder warranty1
MODEL 300135Storage Capacity (L) 135Hourly Recovery (L) 120Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 54
Ø75 NOM.
TPRVALVE1615
328
1490
988
297
425
58°COLD WATER INLET
HOT WATER OUTLET
500
GAS
Rheem
PEOPLE INSTALLATION
Indoor2 - 4
48
Scan code for details & installation
instructions
MODEL 300170Storage Capacity (L) 170Hourly Recovery (L) 126Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 63
Rheem Gas Internal 170L 300170
Features & Benefits
Suitable for indoor installations
Mains pressure – to service multiple hot water demand at once
An easy replacement for most existing 3 Star internal models
Natural gas model
5 year cylinder warranty1
Australian made
Ø75 NOM.
TPRVALVE1915
1790
1213
403 297
COLD WATER INLET
HOT WATER OUTLET
GAS
425
500
58°
3 - 5PEOPLE INSTALLATION
Indoor
49
Scan code for details & installation
instructions
Rheem 4 Star Gas 90L 347090
Features & Benefits
4 Star energy efficiency
Mains pressure at multiple taps
Easy replacement – common fittings with standard 3 Star models
Natural gas model
7 year cylinder warrany1
MODEL 347090Storage Capacity (L) 90Hourly Recovery (L) 100Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 48
7YEARW
AR R A N
TY
C
YLINDER
1158
1078
588916
328
208
473502
298
422
COLD WATER INLET
GAS INLET
RELIEFVALVEHOT
WATER OUTLET
PEOPLE INSTALLATION
1 - 2 Outdoor
50
Scan code for details & installation
instructions
MODEL 347135Storage Capacity (L) 135Hourly Recovery (L) 113Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 59
Rheem 4 Star Gas 135L 347135
Features & Benefits
4 Star energy efficiency
Mains pressure at multiple taps
Easy replacement – common fittings with standard 3 Star models
Natural and propane gas model
7 year cylinder warrany1
7YEARW
AR R A N
TY
C
YLINDER
COLD WATER INLET GAS
INLET
HOT WATER OUTLET
1558
1478
988
328
208473
502
298
1316
422
RELIEFVALVE
PEOPLE INSTALLATION
2 - 5 Outdoor
51
Scan code for details & installation
instructions
Rheem 4 Star Gas 170L 347170
Features & Benefits
4 Star energy efficiency
Mains pressure at multiple taps
Easy replacement – common fittings with standard 3 Star models
Natural and propane gas model
7 year cylinder warrany1
7YEARW
AR R A N
TY
C
YLINDER
COLD WATER INLET
GASINLET
RELIEFVALVEHOT
WATER OUTLET
1858
1778
1213
1616
403
208473502
298
422
MODEL 347170Storage Capacity (L) 170Hourly Recovery (L) 113Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 69
PEOPLE INSTALLATION
2 - 5 Outdoor
52
Scan code for details & installation
instructions
Rheem 5 Star Gas - 265 350265
Features & Benefits
5 Star energy efficiency
Mains pressure at multiple taps
Strong recovery – to have you back in hot water fast
275L first hour capacity of hot water
Compact size – 490mm diameter
Natural gas model
7 year cylinder warranty¹7YEARW
AR R A N
TY
C
YLINDER
COLD WATER INLET
GASINLET
HOT WATER OUTLET
RELIEFVALVE
RELIEFVALVE
1600
988
332
605
556528
240
490
300 95
302
MODEL 350265Storage Capacity (L) 130Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 75
PEOPLE INSTALLATION
2 - 5 Outdoor
53
Scan code for details & installation
instructions
Rheem 5 Star Gas - 295 350295
Features & Benefits
5 Star energy efficiency
Mains pressure at multiple taps
Strong recovery – to have you back in hot water fast
305L first hour capacity of hot water
Compact size – 490mm diameter
Natural gas model
7 year cylinder warranty¹7YEARW
AR R A N
TY
C
YLINDER
COLD WATER INLET
GASINLET
HOT WATER OUTLET
RELIEFVALVE
1900
1213
407
605
556528
240
490
300 95
302
RELIEFVALVE
MODEL 350295Storage Capacity (L) 160Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 85
3 - 5PEOPLE INSTALLATION
Outdoor
54
Scan code for details & installation
instructions
RheemPlus® 5 Star Gas - 265 354265
7YEARW
AR R A N
TY
C
YLINDER
Features & Benefits
5 Star energy efficiency
Mains pressure at multiple taps
50°C temperature limited models supply hot water at a maximum 50°C in accordance with AS 3498
Natural gas model
7 year cylinder warranty¹
COLD WATER INLET
GASINLET
HOT WATER OUTLET
RELIEFVALVE
RELIEFVALVE
1600
988
332 302
605
556 528
545
490
300 95
240182
MODEL 354265Storage Capacity (L) 130Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections G 3/4BGas Connections RP 1/2Approx. Weight (Empty) kg 76
PEOPLE INSTALLATION
2 - 4 Outdoor
55
Scan code for details & installation
instructions
RheemPlus® 5 Star Gas - 295 354295
7YEARW
AR R A N
TY
C
YLINDER
Features & Benefits
5 Star energy efficiency
Mains pressure at multiple taps
50°C temperature limited models supply hot water at a maximum 50°C in accordance with AS 3498
Natural gas model
7 year cylinder warranty¹
MODEL 354295Storage Capacity (L) 160Hourly Recovery (L) 145Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections G 3/4BGas Connections RP 1/2Approx. Weight (Empty) kg 86
COLD WATER INLET
GASINLET
HOT WATER OUTLET
RELIEFVALVE
RELIEFVALVE
19001213
407 302
605
556 528
545
490
300 95
240182
3 - 5PEOPLE INSTALLATION
Outdoor
56
Scan code for details & installation
instructions
Rheem Stellar® Gas - 330 850330
Features & Benefits
5 Star energy efficiency – uses less gas than 3 or 4 Star water heaters
200L/hour hot water recovery
Advanced technology – the Stellar Superflue®
Mains pressure – to service multiple hot water demands at once
Natural gas model
10 year cylinder warranty1
Australian made
MODEL 850330Storage Capacity (L) 130Hourly Recovery (L) 200 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 70
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
GASINLET
485
558
29993
988
252
328
520
298210
1600 252 252
PEOPLE INSTALLATION
2 - 5 Outdoor
57
Scan code for details & installation
instructions
Rheem Stellar® Gas - 360 850360
Features & Benefits
5 Star energy efficiency – uses less gas than 3 or 4 Star water heaters
200L/hour hot water recovery
Advanced technology – the Stellar Superflue®
Mains pressure – to service multiple hot water demands at once
Natural gas model
10 year cylinder warranty1
Australian made
MODEL 850360Storage Capacity (L) 160Hourly Recovery (L) 200 Relief Valve Setting (kPa) 1400Expansion Control Valve (kPa) 1200Max Water Supply Pressure:
with ECV (kPa) 960without ECV (kPa) 1120
Water Connections RP 3/4
Gas Connections RP 1/2Approx. Weight (Empty) kg 80
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
GASINLET
485
558
29993
1213
252
409
520
298210
1900252 252
PEOPLE INSTALLATION
3 - 6 Outdoor
58
Scan code for details & installation
instructions
Rheem Heavy Duty Gas 260L 630260
Features & Benefits
Supply large quantities of hot water
Double layer of vitreous enamel
Adjustable thermostat
Equa-Flow® system allows for flexibility in installation
Natural gas & Propane model
5 year commercial warranty on cylinder1
MODEL 630260Storage Capacity (L) 260Thermal Input (MJ/hr) 51 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 1/2Approx. Weight (Empty) kg 106
*First hour delivery calculated @ 50oC rise
Outdoor
INSTALLATIONFIRST HR DEL
385L*
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
GAS
15201640
990
330300
680655
420
590
295
27O
59
Scan code for details & installation
instructions
MODEL 620260Storage Capacity (L) 260Thermal Input (MJ/hr) 51 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 1/2Approx. Weight (Empty) kg 98
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
GAS
1520
1320
1660
100
330 300
590
67027O
*First hour delivery calculated @ 50oC rise
Indoor
INSTALLATIONFIRST HR DEL
385L*Rheem Heavy Duty Gas 260L 620260
Features & Benefits
Supply large quantities of hot water
Double layer of vitreous enamel
Adjustable thermostat
Equa-Flow® system allows for flexibility in installation
Natural gas & Propane model
5 year commercial warranty on cylinder1
60
Scan code for details & installation
instructions
*First hour delivery calculated @ 50oC rise
Rheem Heavy Duty Gas 265L 631265
Features & Benefits
Multi-Fin™ technology means faster, more efficient heating
Electronic ignition for economy
Equa-Flow® system allows for flexibility in installation
Digital adjustable thermostat to 82°C for sanitisation applications
BMS option available
Natural gas, Propane & Butane model
5 year commercial warranty on cylinder1
MODEL 631265Storage Capacity (L) 265Thermal Input (MJ/hr) 110 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 3/4
Approx. Weight (Empty) kg 146
Outdoor
INSTALLATIONFIRST HR DEL
620L*
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
GAS
16551835
750
700
380
710660
420
610
302
36O
61
Scan code for details & installation
instructions
*First hour delivery calculated @ 50oC rise
Features & Benefits
Multi-Fin™ technology means faster, more efficient heating
Electronic ignition for economy
Equa-Flow® system allows for flexibility in installation
Digital adjustable thermostat to 82°C for sanitisation applications
BMS option available
Natural gas, Propane & Butane model
5 year commercial warranty on cylinder1
MODEL 621265Storage Capacity (L) 265Thermal Input (MJ/hr) 110 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 3/4
Approx. Weight (Empty) kg 137
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
GAS
1655
1795
125
750
700
380
610
750660
302
36O
Indoor
INSTALLATIONFIRST HR DEL
620L*Rheem Heavy Duty Gas 265L 621265
62
Scan code for details & installation
instructions
*First hour delivery calculated @ 50oC rise
Rheem Heavy Duty Gas 275L 631275 INSTALLATIONFIRST HR DEL
970L*
Features & Benefits
Multi-Fin™ technology means faster, more efficient heating
Electronic ignition for economy
Digital adjustable thermostat to 82°C for sanitisation applications
Outdoor installation or Indoor room sealed with kit (purchased separately)
BMS option available
Natural gas, Propane & Butane model
5 year commercial warranty on cylinder1
MODEL 631275Storage Capacity (L) 265Thermal Input (MJ) 110 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:with ECV (kPa) 680without ECV (kPa) 800Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 3/4
Approx. Weight (Empty) kg 132
MODEL 631275Storage Capacity (L) 275Thermal Input (MJ/hr) 200 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 3/4
Approx. Weight (Empty) kg 187
HOTWATEROUTLET
TRPVALVE
COLDWATERINLET
GAS
16951865
760
700
340
780722
320
640
320
36O
Indoor/Outdoor
63
Scan code for details & installation
instructions
*First hour delivery calculated @ 50oC rise
Indoor
INSTALLATIONFIRST HR DEL
Rheem Heavy Duty Gas 275L 621275
Features & Benefits
Multi-Fin™ technology means faster, more efficient heating
Electronic ignition for economy
Equa-Flow® system allows for flexibility in installation
Digital adjustable thermostat to 82°C for sanitisation applications
BMS option available
Natural gas, Propane & Butane model
5 year commercial warranty on cylinder1
MODEL 621275Storage Capacity (L) 275Thermal Input (MJ/hr) 200 Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections (BSPF) RP 11/4
Gas Connections (BSPF) RP 3/4
Approx. Weight (Empty) kg 172
HOTWATEROUTLET
TPRVALVE
COLDWATERINLET
GAS
1695
1895
200
760
700
340
640
780722
320
36O
970L*
64
Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product
warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater
models of the same capacity.
Scan code for details & installation
instructions
Gas C
ontinuo
us Flo
w
65
66
67
Scan code for details & installation
instructions
Rheem 12L 876612, 874612
Features & Benefits
12 L/min continuous hot water delivery @ 25oC rise
Remote Temperature Controller options
Accessories: Pipe cover 299841, Recess Box 299842, 299842/WA Security Cage 299867
50°C models available, requiring no tempering valve3
LED display for easy fault diagnosis
Natural gas & Propane models
10 year heat exchanger warranty1
MODEL 876612 874612
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 94Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 16
ENERGY EFFICIENTSTAR
CL
592
5753
163
1610
90
350
490
54
520
592
4543
12543
126
51
GASCONNECTION
COLD WATER INLET
HOT WATEROUTLET
COLD WATER INLET
GAS CONNECTION
HOT WATER OUTLET
560
164
POWER LEAD CONNECTION
MOUNTINGHOLES
PEOPLE INSTALLATION
Outdoor1 - 2
68
Rheem Standard Flue Diverter 299881 - suitable for 12L/16L
Features & Benefits
Enables compliance with relevant national and local regulations for installation in covered open areas.*
Suitable for Rheem 12L or Rheem Metro 16L
Offers added flexibility in installation
Fits simply to the water heater
Natural gas model
Suitable for installation with Recess Box 299842, 299842/WA Pipe Cover 299841
Fe
PART 299881To suit models:876612NF, 874612NF876E16NF, 874E16NF
379
520
350
245
262
160
*Confirm with your local authorities that the installationcomplies with all regulations applicable in your area.
INSTALLATION
Outdoor
69
Scan code for details & installation
instructions
Rheem Metro 16L 876E16, 874E16
Features & Benefits
16 L/min continuous hot water delivery @ 25oC rise
60ºC hot water for kitchen and laundry
50ºC models provide added safety
Remote Temperature Controller options for added convenience and safety
LED display for easy fault diagnosis
Natural gas & Propane models
10 year heat exchanger warranty¹
MODEL 876E16 874E16
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 126Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 16
CL
592
5753
163
1610
90
350
490
54
520
592
4543
12543
126
51
GASCONNECTION
COLD WATER INLET
HOT WATEROUTLET
COLD WATER INLET
GAS CONNECTION
HOT WATER OUTLET
560
164
POWER LEAD CONNECTION
MOUNTINGHOLES
ENERGY EFFICIENTSTAR
PEOPLE INSTALLATION
Outdoor1 - 3
70
Scan code for details & installation
instructions
Rheem 20L 876620, 874620
Features & Benefits
20 L/min continuous hot water delivery @ 25oC rise
Remote Temperature Controller options
50°C models available, requiring no tempering valve3
LED display for easy fault diagnosis
Natural gas & Propane models
Accessories: Pipe Cover 299841, Recess Box 299842, 299842/WA Security Cage 299867
10 year heat exchanger warranty1
MODEL 876620 874620
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 153Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 16
CL
592
5753
163
1610
90
350
490
54
520
592
4543
12543
126
51
GASCONNECTION
COLD WATER INLET
HOT WATEROUTLET
COLD WATER INLET
GAS CONNECTION
HOT WATER OUTLET
560
164
POWER LEAD CONNECTION
MOUNTINGHOLES
ENERGY EFFICIENTSTAR
PEOPLE INSTALLATION
2 - 4 Outdoor
71
Scan code for details & installation
instructions
Rheem Metro Plus 24L 875E24, 871E24
Features & Benefits
24 L/min continuous hot water delivery @ 25oC rise
Remote Temperature Controller options
50°C models available, requiring no tempering valve3
Digital display for easy fault diagnosis
Natural gas & Propane models
Accessories: Pipe Cover 299848, Recess Box 299842, 299842/WA, Security Wall Mounting 299868, Security Cage 299867
10 year heat exchanger warranty1
MODEL 875E24 871E24
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 19
ENERGY EFFICIENTSTAR
17HOT WATER
OUTLETGAS INLET
GASCONNECTIONCOLDWATER INLET
COLDWATER INLET
HOT WATEROUTLETPOWER
CONNECTION
350
90 19
44
562565605
112127
21132
53 103
16
205
50
10
65
647
92
MOUNTING HOLES
CL
PEOPLE INSTALLATION
Outdoor4 - 5
72
Scan code for details & installation
instructions
Rheem 24L 875624, 871624
Features & Benefits
24 L/min continuous hot water delivery @ 25oC rise
Flamesafe® overheat protection
Remote temperature controller options
50°C models available, requiring no tempering valve3
Digital display for easy fault diagnosis
Natural gas & Propane models
10 year heat exchanger warranty1
MODEL 875624 871624
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 21
ENERGY EFFICIENTSTAR
17HOT WATER
OUTLETGAS INLET
GASCONNECTIONCOLDWATER INLET
COLDWATER INLET
HOT WATEROUTLETPOWER
CONNECTION
350
90 19
44
562565605
112127
21132
53 103
16
205
50
10
65
647
92
MOUNTING HOLES
CL
PEOPLE INSTALLATION
4 - 5 Outdoor
73
Scan code for details & installation
instructions
33
379
350
137119
305205
*Confirm with your local authorities that the installation complies with all regulations applicable in your area.
PEOPLE INSTALLATION
MODEL 875E24NF-FDMin. Operating Flow rate (L/min) 2.7Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 19
Features & Benefits
Enables compliance with relevant national and local regulations for installation in covered open areas.*
Adjustable to deliver 50OC at the nearest tap
Recess Box available -299842 to set water heater into the wall. Compatible with flue diverter.
Digital display for easy fault diagnosis and service
Natural gas model
10 year heat exchanger warranty¹
OutdoorRheem Metro Plus 24L Standard Flue Diverter 875E24NF-FD
4 - 5
74
Scan code for details & installation
instructions
Rheem Metro Plus 24L Extended Flue Diverter 875E24NF-FE
MODEL 875E24NF-FE
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 188Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connections R 3/4
Approx. Weight (Empty) kg 19
Features & Benefits
Enables compliance with relevant national and local regulations for installation in covered open areas.*
Digital display for easy fault diagnosis
Natural gas model
10 year heat exchanger warranty¹
Edge ofbalcony
565
350 Edge ofbalcony
137119
30566
591
no greater than 695
938
350
205
*Confirm with your local authorities that the installation complies with all regulations applicable in your area.
PEOPLE INSTALLATION
Outdoor4 - 5
75
Scan code for details & installation
instructions
Rheem Metro Max 26L 875E26, 871E26
Features & Benefits
26 L/min continuous hot water delivery @ 25oC rise
Remote Temperature Controller options
50°C models available, requiring no tempering valve3
Digital display for easy fault diagnosis
Natural gas & Propane models
Accessories: Pipe Cover 299848, Recess Box 299842, 299842/WA, Security Wall Mounting 299868, Security Cage 299867
10 year heat exchanger warranty1
MODEL 875E26 871E26
Min. Operating Flow rate (L/min) 2.7 Nom. Gas Consumption (MJ/hr) 199Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 21
ENERGY EFFICIENTSTAR
17HOT WATER
OUTLETGAS INLET
GASCONNECTIONCOLDWATER INLET
COLDWATER INLET
HOT WATEROUTLETPOWER
CONNECTION
350
90 19
44
562565605
112127
21132
53 103
16
205
50
10
65
647
92
MOUNTING HOLES
CL
PEOPLE INSTALLATION
Outdoor4 - 5
76
Scan code for details & installation
instructions
Rheem 27L 876627, 874627
Features & Benefits
27 L/min continuous hot water delivery @ 25oC rise
Remote Temperature Controller options for added convenience and safety
50°C models available, requiring no tempering valve3
Digital display for easy fault diagnosis
Natural gas & Propane models
10 year heat exchanger warranty1
MODEL 876627 874627
Min. Operating Flow rate (L/min) 2.0 Nom. Gas Consumption (MJ/hr) 205Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connection R 3/4
Approx. Weight (Empty) kg 24
HOT WATEROUTLET
GASCONNECTION
COLD WATER INLET
POWER LEAD CONNECTION
35126990 17
42
669
132 127 226
54
669
227
9764
28
84
CL
601
ENERGY EFFICIENTSTAR
PEOPLE INSTALLATION
Outdoor4 - 6
77
Scan code for details & installation
instructions
Rheem 27L Internal 866627, 864627
Features & Benefits
27 L/min continuous hot water delivery @ 25oC rise
Remote Temperature Controller options for added convenience and safety
Rheem co-axial flue system
50°C models available, requiring no tempering valve3
Digital display for easy fault diagnosis
Natural gas model
10 year heat exchanger warranty1
MODEL 866627 864627
Min. Operating Flow rate (L/min) 2.0 Nom. Gas Consumption (MJ/hr) 205Max Water Supply Pressure (kPa) 1000Min Water Supply Pressure (kPa) 140Water Connections R 3/4
Gas Connections R 3/4
Approx. Weight (Empty) kg 24
ENERGY EFFICIENTSTAR
351 240
21
5338
10 to 40
131
17
763
132 1275
240119
8628
107
707650
49
331Ø127
HOT WATER OUTLET
HOT WATEROUTLET
COLD WATERINLET
POWER LEAD CONNECTION
POWER LEADCONNECTION
GASCONNECTION
GASCONNECTION
COLD WATER INLET
CL
PEOPLE INSTALLATION
Indoor4 - 6
78
Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627
Approx
255
Approx
192
Approx
207
Approx
270 Approx
500Approx
380
Approx 400295118 90° Bend
210
260
280
400
Approx
153
295119 45° Bend
295116 Horizontal Terminal
Ø127 Ø76
97
227
295117 Vertical Terminal
300 260140
Ø233
Ø208
PART DESCRIPTION WHERE USED
295116 Horizontal Terminal Required where flue terminates horizontally
295117 Vertical Terminal Required where flue terminates vertically
295118 90º Bend Maximum of 3 per installation
295119 45º Bend Maximum of 6 per installation (with no 90º bends)
Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.
79
Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627
295126 Straight Length 300mm
277
295124 MM Adapter
187
295123 FF Adapter
213
295125 Trim Ring
Ø230
Ø133
887
295122 – Straight Length 900mm
PART DESCRIPTION WHERE USED
295122 Straight Length 900mm Long straight sections
295123 Female Female Adapter
Required to reverse flue pipe direction to allow condensate to drain away correctly from water heater in long horizontal sections of horizontally terminating flues
295124 Male Male Adapter
Required to reverse flue pipe direction to allow condensate to drain away correctly from water heater in long horizontal sections of horizontally terminating flues
295125 Trim Ring (optional) Conceal internal and/or external hole in wall or ceiling terminating flues
295126 Straight Length 300mm Short straight sections
Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.
80
Rheem Continuous Flow Flue Components Suitable for 866627, 864627, 862627
295139 Condensate Trap
295129 – Bracket
145 180
Ø127 25
295127 – Adjustable Straight 560 – 890mm
890 MAX 560 MIN
PART DESCRIPTION WHERE USED
295127 Adjustable Length 560 – 890mm Allows to trim flue to exact length required
295129 Bracket Support flue at intervals not exceeding 2m and after any bend
295139 Condensate Trap Required with every condensate drain. Can be connected to a common waste
Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.
Rheem INTERNAL Continuous Flow Water Heater must only be installed using certified Rheem coaxial flue components. Do not use any other type of flue system. Carefully follow the installation instructions.
81
Rheem Continuous Flow Flue System Typical Internal Flue Installation
295116295126295118
295125(optional)
295117
295122
295126
295139
FLASHING (not supplied)
13.5m MAXIMUM*
VERTICAL TERMINAL
Horizontal termination to adjacent wall
Direct Vent Horizontal Wall Direct Vent Vertical Termination
* Note: Maximum flue length with no bends is 13.5m. Reduce the maximum length by 1.5m for every 90° bend and reduce the maximum length by 0.75m for every 45° bend.
Flue termination must comply with the requirements of AS/NZS 5601.1
Refer to Rheem Owner’s Guide and Installation Instruction for details.
13.5m MAXIMUM LINEAL LENGTH* SUBTRACT 1.5M PER 90˚ BEND OR 0.75m PER 45˚ BEND
295124 295127 295122 295123 295116
295125295118
295126/ 295122/ 295127
20mm
1000mm
SLOPE
82
Controllers Rheem Standard and Deluxe Electronic Temperature Controllers
Features & Benefits
Suitable for all Rheem Continuous Flow models
Allows you to choose the desirable hot water temperature
Standard or Deluxe models
Deluxe controllers offer a “bath fill’ mode to turn off the water flow once the bath is filled
Deluxe Temperature Controller with cable
299858 - Kitchen
299859 - Bathroom 1
299860 - Bathroom 2
Controllers and cable also available separately
Temperature Controller with cable
299850 - Kitchen
299851 - Bathroom 1
299852 - Bathroom 2
83
Scan code for details & installation
instructions
Rheem EZ Link® 290141
Features & Benefits
Suitable for use with all Rheem 12,16, 20 and 27 L/min Continuous Flow gas water heater models
Flexible delivery of up to 54 L/min
Staged heating, so energy usage corresponds only to the hot water demand
2 units means no loss of hot water supply in the event of a unit breakdown
Optional remote controller for temperature control, easy fault diagnosis and service
MODEL 290141Suitable for Rheem 12,16, 20 and 27 L/min models
Refer to EZ Link Owner’s Guide and Installation Instructions for the set up procedure.
84
Rheem Security Cage 299867
Rheem Security Cage for use with all Rheem continuous flow gas water heater models.
The kit contains:
1. Security cage
2. Top mounting bracket
3. Bottom mounting bracket
4. Securing fasteners
1
4
2
3
1030
261
600
508
565
85
Rheem Security Wall Bracket 299868
Suitable for most Rheem Continuous Flow units
Flat Security Bracket – to be fixed to the masonry wall with supplied anchors and shear-off nuts.
U Shaped Security Bracket –to be fastened to flat bracket using a padlock (padlock not supplied)
A
B
190
233
117
42
30
86
168
33
42
PART 299868Suitable for models: 875E24, 871E24, 875624, 871624, 875E26, 871E26, 876627, 874627
B
A
Hole sizeØ7mm
86
Rheem Recess Box 299842 (12-26L), 299831 (27L)
PART NO. FASCIA CAVITY
Height Width Depth Height Width DepthA B C D E F
299842 (12-26L) 1088 425 25 1010 347 160299831 (27L) 1081 435 50 1010 352 160299842/WA (12-26L) 1088 425 59 1015 347 125299831/WA (27L) 1091 435 85 1018 353 125
Security BracketRequires Padlock(not Supplied)
TH
0
0
The installation position of the Rheem Continuous Flow unit must comply with AS 5601 or AS/NZS 5601.1. This should be considered when choosing the installation position of the Recess box.
Features & Benefits
Galvanised Steel
Especially designed for standard double brick construction, WA models suit solid brick construction
In-built anti-theft bracket
Easy access door
Scan code for details & installation
instructions
87
Scan code for details & installation
instructions
Rheem Pipe Cover Kit 299841, 299848, 299830
The Pipe Cover is to be installed after the Continuous Flow water heater has been installed. The pipe cover is designed to be installed underneath the water heater to cover the pipe work and valves, but cannot cover the external GPO.
The kit contains:
1. Pipe cover housing
2. Pipe cover access panel
1
2
MODEL299841 suitable for 12-20L/min299848 suitable for 24L/min and 26L/min299830 suitable for 27L/min
Indoor/Outdoor3 - 5
PEOPLE INSTALLATION
88
Scan code for details & installation
instructions
Rheem Pronto® 834012
Features & Benefits
Easy installation matching common mechanical water heater fittings
6 Star energy efficiency
12 L/min continuous hot water delivery @ 25oC rise
Electronic temperature control
Overheat protection
No electrical connection required
Available in natural and propane
Optional heat shield available - 299880
10 year heat exchanger warranty1
MODEL 834012Min. Operating Flow rate (L/min) 3.0 Nom. Gas Consumption (MJ/hr) 99 NaturalNom. Gas Consumption (MJ/hr) 96 PropaneMax Water Supply Pressure (kPa) 800Min Water Supply Pressure (kPa) 120Water Connections R1/2
Gas Connection Rp 3/4
Approx. Weight (Empty) kg 21
ENERGY EFFICIENTSTAR
3 - 4 Outdoor1 - 2
840
45
HOTWATEROUTLET
HOT WATEROUTLET
COLD WATERINLET
COLDWATERINLET
GAS INLET(FLUSH TO
BASE)
GAS INLET
45388
120 120
222
465
70
69 55 69
70
285
268
R3.5
R8
120 120
CL
Indoor/Outdoor
PEOPLE INSTALLATION
1 - 2 Outdoor
89
Scan code for details & installation
instructions
Rheem Pronto® 834016
Features & Benefits
Easy installation matching common mechanical water heater fittings
5.9 Star (NG) 5.8 Star (Propane)
16 L/min continuous hot water delivery @ 25oC rise
Electronic temperature control
Overheat protection
No electrical connection required
Available in natural and propane
Optional heat shield available - 299880
10 year heat exchanger warranty1
MODEL 834016Min. Operating Flow rate (L/min) 3.0 Nom. Gas Consumption (MJ/hr) 128 NaturalNom. Gas Consumption (MJ/hr) 125 PropaneMax Water Supply Pressure (kPa) 800Min Water Supply Pressure (kPa) 140Water Connections R1/2
Gas Connection Rp 3/4
Approx. Weight (Empty) kg 25
1 - 3 Outdoor
875
50
HOTWATEROUTLET
HOT WATEROUTLET
COLD WATERINLET
COLDWATERINLET
GAS INLET(FLUSH TO
BASE)
GAS INLET
50443
120 120
222
451
84
69 48 69
84
285
268
R3.5
R8
120 120
CL
ENERGY EFFICIENTSTAR
5.9
PEOPLE INSTALLATION
1 - 3 Outdoor
Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product
warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater
models of the same capacity.3 60ºC and higher temperature models and some applications require a
tempering valve in accordance with AS 3500.4.
Scan code for details & installation
instructions
So
lar
91
92
93
Scan code for details & installation
instructions
Rheem Loline 160L 511161
MODEL 511161Storage Capacity (L) 165Solar Collectors (VIC or SA) 1 CSA2612Solar Collectors (VIC only) 2 LCSBooster Type GasWeight Empty (kg)- Tank without booster 52Weight Empty (kg)- Tank with booster 73Tank Water Connections RP 3/4
Gas Booster Water Connections R 3/4
Gas Connection R 3/4
Features & Benefits
Split system design – vitreous enamel lined cylinder installed at ground level
Limited frost protection4
24 L/min in-series gas booster site integrated or Rheem 27L/min in-series gas booster installed remotely
Suitable with CSA2612 collector (VIC & SA) or 2 LCS collectors (VIC only)
Eligible for STCs5
5 year cylinder warranty1
110°
23°
695514
480
65° 47°
1615
987937
105
395
52961
SOLARPREHEATOUTLET
SOLAR HOT(FROMCOLLECTOR)INLET
COLD WATERINLET
SOLAR COLD(TO COLLECTOR) OUTLET
PEOPLE INSTALLATION
Outdoor1 - 4
94
Scan code for details & installation
instructions
Rheem Loline 270L 511271
MODEL 511271Storage Capacity (L) 270Solar Collectors 2 or 3 NPT200,
2 LCSBooster Type Electric or GasElement size (kW) 3.6Weight Empty (kg) - Tank 71Water Connections RP 3/4
Features & Benefits
Split system design – vitreous enamel lined cylinder installed at ground level
Limited frost protection4
Booster – choice of electric element or 6-Star continuous flow gas
Gas booster tank mounting kit available
2 or 3 NPT200 or 2 LCS collectors
Eligible for STCs5
5 year cylinder warranty1
640
1395
73
588
73
412
1112
680
32o
88o
32o
COLD WATERINLET
HOT WATEROUTLET
ELECTRICALCABLE ENTRYSOLAR HOT INLET
(FROM COLLECTOR)
SOLAR COLDOUTLET(FROMCOLLECTOR)
TPRVALVE
PEOPLE INSTALLATION
2 - 5Indoor/Outdoor
95
Scan code for details & installation
instructions
Rheem Loline 325L 511325
MODEL 511325Storage Capacity (L) 325Solar Collectors 2 or 3 NPT200,
2 LCSBooster Type Electric or GasElement size (kW) 3.6Weight Empty (kg) - Tank 87Water Connections RP 3/4
Features & Benefits
Split system design – vitreous enamel lined cylinder installed at ground level
Limited frost protection4
Booster – choice of electric element or 6-Star continuous flow gas
Gas booster tank mounting kit available
2 or 3 NPT200 or 2 LCS collectors
Eligible for STCs5
5 year cylinder warranty1
640
1640
73
710
73
481
1357
680
32o
88o
32o
COLD WATERINLET
HOT WATEROUTLET
ELECTRICALCABLE ENTRY
T&PRVALVE
SOLAR HOTINLET
(FROMCOLLECTOR)
SOLAR COLDOUTLET(FROMCOLLECTOR)
PEOPLE INSTALLATION
2 - 6Indoor/Outdoor
96
Scan code for details & installation
instructions
Rheem Loline 410L 511410
MODEL 511410Storage Capacity (L) 410Solar Collectors 2, 3 or 4 NPT200,
2 or 3 LCSBooster Type Electric or GasElement size (kW) 3.6Weight Empty (kg) - Tank 111Water Connections RP 3/4
Features & Benefits
Split System design – vitreous enamel lined cylinder installed at ground level
Limited frost protection4
Booster – choice of electric element or 6-Star continuous flow gas
2, 3 or 4 NPT200 or 2 or 3 LCS collectors
Eligible for STCs5
5 year cylinder warranty1
690
1840
81
795
81
532
1519
730
30o
82o
30o
COLD WATERINLET
HOT WATEROUTLET
ELECTRICALCABLE ENTRYSOLAR HOT INLET
(FROM COLLECTOR)
SOLAR COLDOUTLET(FROMCOLLECTOR)
T&PRVALVE
PEOPLE INSTALLATION
3 - 7Indoor/Outdoor
97
Scan code for details & installation
instructions
Rheem Premier® Loline 160L 590160
Features & Benefits
Complete Frost Protection – Unique Drain-Back™ heat exchange technology
Complies with regulations in all states
Booster – 6-star continuous flow gas
Compact spilt system design
1 T200, 2 NPT200 or 2 LCS collectors
Eligible for STCs5
5 year cylinder warranty1
MODEL 590160Storage Capacity (L) 160Solar Collectors 1 T200, 2 LCS
or 2 NPT200Booster Type GasWeight Empty - (kg) Tank 93Tank Water Connections RP 3/4
Gas Booster Water Connections R 3/4
Gas Connections R 3/4
423212
211
503
51
1213
402
1615
1818
1613 18
58
SOLARPREHEATOUTLET
COLDWATERINLET
TPRVALVE
SOLARCONNECTIONS
PEOPLE INSTALLATION
2 - 5 Outdoor
98
Scan code for details & installation
instructions
Rheem Premier® Loline 160L 596160
Features & Benefits
Complete Frost Protection – Unique Drain-Back™ heat exchange technology
Complies with regulations in all states
Booster – 6-star 20 L/min continuous flow gas (factory fitted)
Compact spilt system design
1 T200, 2 NPT200 or 2 LCS collectors
Eligible for STCs5
5 year cylinder warranty1
MODEL 596160Storage Capacity (L) 160Solar Collectors 1 T200, 2 LCS
or 2 NPT200Booster Type GasWeight Empty (kg) - Tank 112Water Connections RP 3/4
Gas Booster Water Connections R 3/4
Gas Connections R 3/4
423212
211
503
690
51
408
805
402
1206
1818
1613 18
58
SOLARPREHEATOUTLET
HOTWATEROUTLET
COLDWATERINLET
TPRVALVE
SOLARCONNECTIONS
PEOPLE INSTALLATION
Outdoor2 - 5
99
Scan code for details & installation
instructions
Rheem Premier® Loline 270L 596270
Features & Benefits
Complete Frost Protection – Unique Drain-Back™ heat exchange technology
Complies with regulations in all states
Booster – 27 L/min 6-star continuous flow gas (site integrated)
Full mains pressure for multiple outlets
Integrated tempering valve
2 or 3 SPA2000 or T200 collectors
Eligible for STCs5
5 year cylinder warranty1
MODEL 596270Storage Capacity (L) 270Solar Collectors 2 or 3 SPA2000
2 or 3 T200Booster Type GasWeight Empty - (kg) Tank without booster 141Weight Empty - (kg) Tank with booster 165Water Connections RP 3/4
Gas Connections R 3/4
16541455
1701
1787
510772
265
351
890
648182
215 324
48o
FLUETERMINAL
PEOPLE INSTALLATION
Outdoor2 - 5
100
Scan code for details & installation
instructions
Rheem Premier® Loline 270L 591270
Features & Benefits
Complete Frost Protection – Unique Drain-Back™ heat exchange technology
Complies with regulations in all states
Booster – electric element
Full Mains Pressure for multiple outlets
2 or 3 SPA2000 or T200 collectors
Eligible for STCs5
5 year cylinder warranty1
MODEL 591270Storage Capacity (L) 270Solar Collectors 2 or 3 SPA2000
2 or 3 T200Booster Type ElectricElement size (kW) 3.6Weight Empty (kg) - Tank 146Weight Empty - (kg) Solar Collector (each)
48
Water Connections RP 3/4
980
1775
1701
1078
377
385344324
648
68247o
73o
ELECTRICALCABLE ENTRY
HOT WATEROUTLET
TPRVALVE
COLD WATERINLET
PEOPLE INSTALLATION
2 - 5Indoor/Outdoor
101
Scan code for details & installation
instructions
Rheem 52L Series 52L180
MODEL 52L180Storage Capacity (L) 180Solar Collectors 1 NPT200, L,
CSA2007Booster Type Electric or GasWeight Empty (kg) - Tank 48Weight Empty - (kg) Solar Collector (each)
33
Water Connections DN15 Compression
Gas Connections DN15 Compression
Features & Benefits
Suitable for temperate or tropical location
Stainless steel cylinder
The 52L Series system directly heats the water as it passes through the collectors
Booster – choice of electric element or 6-Star continuous flow gas
Eligible for STCs5
7 year cylinder warranty1 with NPT200 collector
10 year cylinder warranty1 with L, CSA2007 collector*
7YEARW
AR R A N
TY
C
YLINDER
HOT WATEROUTLET
COLDWATERINLET
TPRVALVE
ELECTRICALCONNECTION 79
1937
563
249011381022
1495
* Available through Rheem Solar Specialists only
PEOPLE INSTALLATION
Outdoor1 - 2
102
Scan code for details & installation
instructions
Rheem 52L Series 52L300
Features & Benefits
Suitable for temperate or tropical location
Stainless steel cylinder
The 52L Series system directly heats the water as it passes through the collectors
Booster – choice of electric element or 6-Star continuous flow gas
Available in four COLORBOND® Steel colours
Eligible for STCs5
7 year cylinder warranty1
10 year cylinder warranty1 with L, CSA2007 collector*
7YEARW
AR R A N
TY
C
YLINDER
MODEL 52L300Storage Capacity (L) 300Solar Collectors 2 NPT200,
L, CSA2007Booster Type Electric or GasWeight Empty (kg) - Tank 72Water Connections DN15 Compression
HOT WATEROUTLETTPRVALVE
ELECTRICALCONNECTION
563 2180
21982094
2490
1937
79
COLDWATERINLET
* Available through Rheem Solar Specialists only
PEOPLE INSTALLATION
Outdoor2 - 5
103
Scan code for details & installation
instructions
Rheem Hiline 52S 52S160
MODEL 52S160 Storage Capacity (L) 160Solar Collectors 1 NPT200Booster Type Electric or GasWeight Empty (kg) - Tank 70Hot Water Connection RP 3/4
Cold Water Connection G 1/2 B
Features & Benefits
Energy efficient
Booster – choice of electric element or 6-Star continuous flow gas
Vitreous enamel lined cylinder
Eligible for STCs5
5 year cylinder warranty1
HOT WATEROUTLET
TPRVALVE
ELECTRICALCONNECTION
79
1937
540
249011381022
1070
COLDWATERINLET
PEOPLE INSTALLATION
Outdoor1 - 2
104
Scan code for details & installation
instructions
Rheem Hiline 52S 52S300
MODEL 52S300 Storage Capacity (L) 300Solar Collectors 2 NPT200Booster Type Electric or gasWeight Empty (kg) - Tank 100Hot Water Connection RP 3/4
Cold Water Connection G 1/2 B
Features & Benefits
Energy efficient
Booster – choice of electric element or 6-Star continuous flow gas
Vitreous enamel lined cylinder
Eligible for STCs5
5 year cylinder warranty1
79
540
19372490
2094
21981022
1865
HOT WATEROUTLET
TPRVALVE
ELECTRICALCONNECTION
COLDWATERINLET
3 - 5INSTALLATIONPEOPLE
Outdoor2 - 5
105
Scan code for details & installation
instructions
Features & Benefits
Complete frost protection
Space saving design – a complete roof mounted installation
Stainless steel cylinder
Booster – choice of electric element or 6-Star continuous flow gas
Eligible for STCs5
7 year cylinder warranty1 with SPA2000, NPT200
10 year cylinder warranty1 with L, CSA2007 collector*
MODEL 52H180Storage Capacity (L) 180Solar Collectors 1 SPA2000,
NPT200, LBooster Type Electric or GasWeight Empty (kg) - Tank 52Hot Water Connection DN15 Compression
Cold Water Connection DN15 Compression
Rheem Premier® Hiline 52H 52H180
HOT WATEROUTLET
COLDWATERINLET
TPRVALVE
ELECTRICALCONNECTION 79
1937
563
249011381022
1495
7YEARW
AR R A N
TY
C
YLINDER
* Models with NPT200, L, CSA2007 collectors available through Rheem Solar Specialists only
INSTALLATIONPEOPLE
1 - 2 Outdoor
106
Scan code for details & installation
instructions
Rheem Premier® Hiline 52H 52H300
Features & Benefits
Complete frost protection
Space saving design – a complete roof mounted installation
Stainless steel cylinder
Booster – choice of electric element or 6-Star continuous flow gas
Eligible for STCs5
7 year cylinder warranty1 with SPA2000, NPT200
10 year cylinder warranty1 with L, CSA2007 collector*
HOT WATEROUTLETTPRVALVE
ELECTRICALCONNECTION
563 2180
21982094
2490
1937
79
COLDWATERINLET
MODEL 52H300Storage Capacity (L) 300Solar Collectors 1 SPA2000,
NPT200, LBooster Type Electric or GasWeight Empty - (kg) Tank 79Hot Water Connection R 3/4
Cold Water Connection RP 1/2
7YEARW
AR R A N
TY
C
YLINDER
* Models with NPT200, L, CSA2007 collectors available through Rheem Solar Specialists only
PEOPLE INSTALLATION
Outdoor2 - 5
107
Scan code for details & installation
instructions
Rheem Premier® Hiline 300L 52C300
MODEL 52C300Storage Capacity (L) 300Solar Collectors 2 NPT200Booster Type Electric or GasWeight Empty - (kg) Tank 109Hot Water Connection DN15 Compression
Cold Water Connection R 3/4
Features & Benefits
Complete frost protection
Energy efficient
Booster – choice of electric element or 6-Star continuous flow gas
Suitable for a range of water supplies
Eligible for STCs5
5 year cylinder warranty1
HOT WATEROUTLET
COLDWATERINLET
T.P.RVALVE
ELECTRICALCONNECTION 77
24252118
1022
19372475
508
2290
PEOPLE INSTALLATION
Outdoor2 - 5
108
Rheem Collectors NPT200, LCS, CSA2007, SPA2000, T200, CSA2612, L
A
B
PIPE WORK TO SOLAR COLLECTORS2.0m2 Collector A B
1 Collector 1240 18752 Collector 2360 18753 Collector 3480 18753 Collector 3480 18752.6m2 Collector
1 Collector 1340 2165
COLLECTOR DATACollector Dimension Weight Kg
(empty)System
NPT200 1943 x 1027 x 82 36 direct/indirect
LCS 1943 x 1027 x 82 31 direct/indirect
CSA2007 1996 x 1043 x 82 36 direct/indirect
SPA2000 1996 x 1043 x 82 45 indirect
T200 1943 x 1027 x 82 48 indirect
CSA2612 2285 x 1130 x 82 47 direct
L 1943 x 1027 x 82 29 direct/indirect
INSTALLATION
Outdoor
109
Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product
warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater
models of the same capacity.3 60ºC and higher temperature models and some applications require a
tempering valve in accordance with AS 3500.4.4 Frost protection to 400m altitude above sea level5 Eligibility criteria apply.
110
Heat P
ump
111
112
Scan code for details & installation
instructions
113
Scan code for details & installation
instructions
HDi-310 551310
Features & Benefits
Top Down heating
No Solar collectors
Energy efficient
Back-up element – Provides hot water regardless of the weather
Fits on a compact footprint
LED display to indicate operating status
Eligible for STCs5
5 year cylinder warranty1
MODEL 551310Storage Capacity (L) 310Element Rating (kW) 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 135
1075
820
1870
679
670643
100300MIN
300MIN
50O
30O
HOTOUTLET
AIRINLET
AIROUTLET
VENTILATIONCLEARANCE
TPRVALVE
CONDENSATEDRAIN
WALL
108
COLDOUTLET
PEOPLE INSTALLATION
Outdoor3 - 6
114
Scan code for details & installation
instructions
MPi-325 Series II 551325
Features & Benefits
Multi-pass heating – Heats the water by passing the water through the heat exchanger multiple times
No Solar collectors
Back up electric element
One man installation – can be fully installed by plumbing regular trades
LED display to indicate operating status
Eligible for STCs5
5 year cylinder warranty1
MODEL 551325Storage Capacity (L) 325Element Rating (kW) 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 130
57432O
300 MIN
894619 275
638
1631
1018
872
544
162
114
1317
100
WALL
AIR INLET
AIR INLET
AIROUTLET
TPRVALVE
HOTOUTLET
COLDINLET
CONDENSATE DRAIN
VENTILATIONCLEARANCE
VENTILATIONCLEARANCE
300 min
ELECTRICALCONNECTION
AIRINLET
AIROUTLET
PEOPLE INSTALLATION
Outdoor2 - 5
115
Scan code for details & installation
instructions
MPi-325 Series II 554325
Features & Benefits
Inbuilt temperature control valve, adjustable to deliver 50ºC at first tap
Multi-pass heating
No Solar collectors
Back up electric element
One man installation – can be fully installed by plumbing regular trades
LED display to indicate operating status
Eligible for STCs5
5 year cylinder warranty1
MODEL 554325Storage Capacity (L) 325Element Rating (kW) 3.6Relief Valve Setting (kPa) 1000Expansion Control Valve (kPa) 850Max Water Supply Pressure:
with ECV (kPa) 680without ECV (kPa) 800
Water Connections RP 3/4
Approx. Weight (Empty) kg 130
57432O
300 MIN
8941006
619 275
638
1636
1018
872
544
114
329
1317
100
WALL
AIR INLET
AIR INLET
AIROUTLET
TPRVALVE
HOTOUTLET
COLDINLET
CONDENSATE DRAIN
VENTILATIONCLEARANCE
VENTILATIONCLEARANCE
300 min
ELECTRICALCONNECTION
AIRINLET
AIROUTLET
PEOPLE INSTALLATION
Outdoor2 - 5
116
Conditions apply:1 See the Rheem warranty in the product’s Owner’s Guide or view product
warranties at www.rheem.com.au/warranty2 Up to 42% lighter than comparable Rheem vitreous enamel water heater
models of the same capacity.3 60ºC and higher temperature models and some applications require a
tempering valve in accordance with AS 3500.4.4 Frost protection to 400m altitude above sea level5 Eligibility criteria apply.
117
® Registered Trademarks of Rheem Australia Pty Ltd. Registered Trademark of COLORBOND Registered Trademark of Equa-flowTM Trademark of Dynabolt
Materials and specifications are subject to change without notice.
®
Rheem Australia Pty LtdABN 21 098 823 511
Head Office1 Alan Street
Rydalmere NSW 2116
Australia
PO Box 7508
Silverwater NSW 2128
Australia
National Sales Phone: 132 552
National Service Phone: 131 031
www.rheem.com.au