2
SENECA XVAULT UNIFIED STORAGE PLATFORM QUICK START GUIDE XV-UM2U35 / XV-UM3U35 / XV-UM4U35 This product contains software that must be registered for continued use and to enjoy the benefits of eligibility for updates. Please take the time to register the operating system and any applications installed on this product. CONTENTS OF XVAULT PACKAGE Quantity Item 1 xVault Unified Storge Platform Appliance 2 Power Cords 1 Bezel with Keys 1 Rackmount Kit with Hardware 1 16GB USB Flash thumb drive for emergency restore 1 32GB USB Flash thumb drive for customer specific configuration backup & restore DEFAULT 1GBE FIXED IP ADDRESSES Port IP Address Mask Management Port 1GbE Port 1 172.16.6.9 255.255.255.0 1GbE Port 2 10.0.10.8 255.255.255.0 1GbE Port 3 10.0.10.9 255.255.255.0 1GbE Port 4 10.0.10.10 255.255.255.0 1GbE Port 5 10.0.10.11 255.255.255.0 1GbE Port 6 10.0.10.12 255.255.255.0 10GbE Port 1 10.10.10.3 255.255.255.0 10GbE Port 2 10.10.10.4 255.255.255.0 MAIN BACK PANEL CONNECTIONS I/O Port Connection Port Usage NIC Port 1 Management Port and Optional IPMI NIC Port 2–6 iSCSI / NAS 1–5 NIC Port 7–8 Optional 10GbE Ports VGA Console USB Port 1 Keyboard USB Port 2 Mouse USB Port 3 USB Port 4 SAS Expansion Port PLEASE STOP AND READ THIS DOCUMENT DEFAULT LOG IN INFORMATION Username: Administrator Password: P@ssw0rd Note: This user has administrative privileges. *XVUSPQS-V2.0* XVUSPQS-V2.0 XVUSPQS-V2.0.1214 1GbE NIC Ports 3–6 / iSCSI-NAS 2–5 Option Slot for 10GbE NIC, 2nd RIAD Controller or Infiband Port 1 USB 1 USB 2 VGA Port 2 RAID Controller SAS Expansion Port Option PCI x8 Option Slot 3 4 5 6 SLOT-1 SLOT-2 SLOT-3 SLOT-4 SLOT-5 SLOT-6 SLOT-7 SLOT-8 SLOT-9 SLOT-10 SLOT-11 SLOT-12 SLOT-13 SLOT-14 SLOT-15 SLOT-16 SLOT-17 SLOT-18 SLOT-19 SLOT-20 SLOT-21 SLOT-22 SLOT-23 SLOT-24 4U 24 BAY SLOT-1 SLOT-5 SLOT-9 SLOT-2 SLOT-6 SLOT-10 SLOT-3 SLOT-7 SLOT-11 SLOT-4 SLOT-8 SLOT-12 2U 12 BAY DRIVE SLOT LOCATIONS BY CHASSIS MODEL SLOT-1 SLOT-5 SLOT-9 SLOT-13 SLOT-2 SLOT-6 SLOT-10 SLOT-14 SLOT-3 SLOT-7 SLOT-11 SLOT-15 SLOT-4 SLOT-8 SLOT-12 SLOT-16 3U 16 BAY Management Port iSCSI-NAS 1

PLEASE STOP AND READ ThIS DOCUMENT

Embed Size (px)

Citation preview

Page 1: PLEASE STOP AND READ ThIS DOCUMENT

SENECA XVAULT UNifiEd STorAgE PLATform QUiCK STArT gUidEXV-UM2U35 / XV-UM3U35 / XV-UM4U35

This product contains software that must be registered for continued use and to enjoy the benefits of eligibility for updates. Please take the time to register the operating system and any applications installed on this product.

CONTENTS OF XVAULT PACKAGEQuantity Item

1 xVault Unified Storge Platform Appliance

2 Power Cords

1 Bezel with Keys

1 rackmount Kit with Hardware

1 16gB USB flash thumb drive for emergency restore

1 32gB USB flash thumb drive for customer specific configuration backup & restore

DEFAULT 1GbE FIXED IP ADDRESSESPort IP Address Mask

management Port1gbE Port 1

172.16.6.9 255.255.255.0

1gbE Port 2 10.0.10.8 255.255.255.0

1gbE Port 3 10.0.10.9 255.255.255.0

1gbE Port 4 10.0.10.10 255.255.255.0

1gbE Port 5 10.0.10.11 255.255.255.0

1gbE Port 6 10.0.10.12 255.255.255.0

10gbE Port 1 10.10.10.3 255.255.255.0

10gbE Port 2 10.10.10.4 255.255.255.0

MAIN bACK PANEL CONNECTIONSI/O Port Connection Port Usage

NiC Port 1 management Port and optional iPmi

NiC Port 2–6 iSCSi / NAS 1–5

NiC Port 7–8 optional 10gbE Ports

VgA Console

USB Port 1 Keyboard

USB Port 2 mouse

USB Port 3

USB Port 4

SAS Expansion Port

PLEASE STOP AND READ ThIS DOCUMENT

DEFAULT LOG IN INFORMATIONUsername: AdministratorPassword: P@ssw0rdNote: This user has administrative privileges.

*XVUSPQS-V2.0*XVUSPQS-V2.0

XVUSPQS-V2.0.1214

1GbE NIC Ports 3–6 / iSCSI-NAS 2–5

Option Slot for 10GbE NIC, 2nd RIAD Controller or Infiband

Port 1

USB 1

USB 2VGA

Port 2

RAID Controller

SAS Expansion Port Option

PCI x8 Option Slot

34

56

SLOT-1 SLOT-2 SLOT-3 SLOT-4

SLOT-5 SLOT-6 SLOT-7 SLOT-8

SLOT-9 SLOT-10 SLOT-11 SLOT-12

SLOT-13 SLOT-14 SLOT-15 SLOT-16

SLOT-17 SLOT-18 SLOT-19 SLOT-20

SLOT-21 SLOT-22 SLOT-23 SLOT-24

4U 24 bAY

SLOT-1

SLOT-5

SLOT-9

SLOT-2

SLOT-6

SLOT-10

SLOT-3

SLOT-7

SLOT-11

SLOT-4

SLOT-8

SLOT-12

2U 12 bAY

DRIVE SLOT LOCATIONS bY ChASSIS MODEL

SLOT-1

SLOT-5

SLOT-9

SLOT-13

SLOT-2

SLOT-6

SLOT-10

SLOT-14

SLOT-3

SLOT-7

SLOT-11

SLOT-15

SLOT-4

SLOT-8

SLOT-12

SLOT-16

3U 16 bAY

Management Port iSCSI-NAS 1

Page 2: PLEASE STOP AND READ ThIS DOCUMENT

Manual Location: The manual is in electronic format, the link to open is on the “Startup” screen which can be opened by hitting the “Start” key. The manual is downloadable from the Seneca web site at http://www.xvaultstorage.com/change/USP_manual/manual.pdf.

hOw TO CONFIGURE ALERTS

1. Select and login to megarAid Storage manager from the desktop.

2. Select Tools Monitor Configure Alerts

3. Select the Mail Server tab and enter the proper information.

4. Select Email tab and enter recipient information

Use to Identify SenderPreceding “@”: Alpha numeric with “_” only @

After “@”: Alpha numeric only

Name or IP Address“25” is standard SmTP port. Can be changed by unchecking “Use default”.

Only If Required

“Save backup” if configuration retention is desired.

“Load backup” if configuration saved earlier.

XVAULT SUPPORTSeneca customer care group stand ready to assist with any hardware and operat-ing system assistance.

Contact Seneca Digital Security and Surveillance Support:

Normal Business Hours outside Business Hours

800.227.3432 option 5 888.227.9994Available monday–friday 8am–6pm EST

Download the complete user manual at http://www.xvaultstorage.com/change/USP_manual/manual.pdf.

First level of data protection and integrity begins with AC power protection.

Please consult your Seneca Account Manager for properly sized, uninterruptable power supply (UPS).

New recipient email address:Enter all new email recipients and press “Add” “Test“ will send a brief message to all recipients.

Clicking “OK” will only hold recipi-ents for this mSm session only.

new email address

NOTE: Please reference manual for more detailed configuration information.

wARNING: Power on self test takes several minutes until boots process.

INITIAL SETUP OUTLINES:

rack mount Equipment

Create Virtual disksmanual page 44

route and Connect Signal and AC Power Cables

manual page 24

Create Volume(s)manual page 51

gather Site Specific Addressing and Volume information

iSCSi Volume Creationmanual page 59

find Host iQN Numbermanual page 59

Consult manualConnect iSCSi Volume to Server

manual page 66

Change iP Addressessmanual page 26

Backup New Configurationsmanual page 89

review Shipped rAid Sets

Create Pool Spacemanual page 40

Bring online