1 of 44 Number: 0585 Policy *Please see amendment for Pennsylvania Medicaid at the end of this CPB. Implantable Cardioverter‐Defibrillators Aetna considers Food and Drug Administration‐approved implantable cardioverter‐defibrillators (thoracotomy and non‐ thoracotomy systems) medically necessary for any of the following groups of individuals, except where contraindicated: I. Members after one or more episodes of spontaneously occurring and inducible ventricular fibrillation (VF), or syncopal or hypotensive ventricular tachycardia (VT) that is not associated with acute myocardial infarction (AMI)]; and not due to a remediable cause (e.g., drug toxicity, electrolyte abnormalities, ischemia); or II. Members after spontaneously occurring but non‐inducible documented syncopal or hypotensive VT that was not due to AMI; or III. Members after VT/VF cardiac arrest that was not associated with an inducible ventricular arrhythmia, and not due to AMI; or IV. Members with structural heart disease (such as prior myocardial infarction (MI), congenital heart disease, and/or ventricular dysfunction) and spontaneous, sustained VT Last Review 06/08/2017 Eective: 02/05/2002 Next Review: 06/07/2018 Review History Definitions Clinical Policy Bulletin Notes

*Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

1 of 44

Number: 0585

Policy *Please see amendment for Pennsylvania Medicaid at the end of this CPB. Implantable Cardioverter‐Defibrillators

Aetna considers Food and Drug Administration‐approved implantable cardioverter‐defibrillators (thoracotomy and non‐ thoracotomy systems) medically necessary for any of the following groups of individuals, except where contraindicated:

I. Members after one or more episodes of spontaneously

occurring and inducible ventricular fibrillation (VF), or syncopal or hypotensive ventricular tachycardia (VT) that is not associated with acute myocardial infarction (AMI)]; and not due to a remediable cause (e.g., drug toxicity, electrolyte abnormalities, ischemia); or

II. Members after spontaneously occurring but non‐inducible documented syncopal or hypotensive VT that was not due to AMI; or

III. Members after VT/VF cardiac arrest that was not associated with an inducible ventricular arrhythmia, and not due to AMI; or

IV. Members with structural heart disease (such as prior myocardial infarction (MI), congenital heart disease, and/or ventricular dysfunction) and spontaneous, sustained VT

Last Review 06/08/2017 Effective: 02/05/2002 Next Review: 06/07/2018

Review History

Definitions

Clinical Policy Bulletin Notes

Page 2: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

2 of 44

(greater than 30 seconds), whether hemodynamically stable or

unstable; or I. Members with sustained VT (greater than 30 seconds) and

normal or near‐normal ventricular function; or II. Members after unexplained syncope, which by history and

clinical circumstances was probably due to a ventricular tachyarrhythmia, with either of the following: 1) the presence

of reproducible inducible syncopal or hypotensive VT or VF that is not associated with AMI and not due to a remediable

cause; or 2) significant left ventricular (LV) dysfunction (LV ejection fraction less than 50 %), and structural heart disease

such as prior myocardial infarction (MI), congenital heart disease, and/or ventricular dysfunction; or

III. Members with ischemic dilated cardiomyopathy* with a history of heart attack and one of the following: (i) New York

Heart Association (NYHA) Class II or III heart failure (see appendix) with a LVEF less than or equal to 35 %, who are at

least 40 days post MI, and are on optimal medical therapy, defined as 3 months of maximally titrated doses as tolerated

of an ACE inhibitor, beta‐blocker, and diuretic; or (ii) NYHA Class I heart failure (see appendix) with a LVEF less than or

equal to 30 %, who are at least 40 days post MI, and are on optimum medical therapy; or (iii) non‐sustained VT due to

prior MI, and LVEF less than or equal to 40 %, and inducible VF or sustained VT at EP study performed at least 96 hours after

revascularization or MI; or IV. Members with non‐ischemic dilated cardiomyopathy, NYHA

Class II or III heart failure (see appendix), and a LVEF less than or equal to 35 % who are on optimal medical therapy, defined

as 3 months of maximally titrated doses as tolerated of an ACE inhibitor, beta‐blocker, and diuretic; or

V. Members with familial or inherited conditions with a high‐risk of life‐threatening ventricular tachyarrhythmias, including:

A. Long QT syndrome with either of the following:

1. Syncope and/or VT while receiving beta‐blockers; or 2. Asymptomatic with one or more of the following risk

factors for sudden cardiac death:

a. QTc greater than 500 msec, or b. LQT2 or LQT3; or

Page 3: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

3 of 44

c. Family history of sudden death

B. Hypertrophic cardiomyopathy or arrhythmogenic right ventricular cardiomyopathy (ARVC) with one or more of the following risk factors for sudden cardiac death:

1. Documented VT; or 2. Family history of sudden cardiac death in at least one

first‐degree relative; or 3. Left ventricular thickness of 3 cm or greater; or 4. Hypotensive response to exercise treadmill testing (ETT);

or 5. At least one episode of unheralded syncope within the

previous 12 months.

C. Catecholaminergic polymorphic VT who have syncope and/or documented sustained VT while receiving beta‐ blockers.

D. Brugada Syndrome who have had syncope or who have documented or inducible VT.

E. LV non‐compaction cardiomyopathy with either of the following:

1. Positive family history of sudden cardiac death; or 2. Impaired left ventricular ejection fraction (less than 50

%)

F. Cardiac sarcoidosis, giant cell myocarditis, or Chagas disease, regardless of LV ejection fraction

G. ICD implantation may be considered in affected members with a familial cardiomyopathy associated with sudden death.

* Note: Ischemic cardiomyopathy is defined as left ventricular systolic dysfunction associated with marked stenosis (at least 75 % narrowing) of at least 1 of the 3 major coronary arteries, or a documented history of myocardial infarction.

Page 4: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

4 of 44

Aetna considers ICDs with hemodynamic (fluid status) monitoring experimental and investigational because of a lack of reliable evidence of efficacy and safety.

Aetna considers the use of implantable cardioverter‐defibrillators in persons with left ventricular assist devices (LVADs) experimental and investigational because the effectiveness of this approach has not been established.

Notes:

Aetna considerrs replacement of an implantable cardioverter defibrillator pulse generator and/or leads medically necessary when damaged, malfunctioning, when replacement is recommended according to the manufacturer's instructions in the product labeling, or due to a change in the member's medical condition.

Aetna considers implantable cardioverter‐defibrillators experimental and investigational for other indications because its safety and effectiveness has not been established.

Subcutaneous Cardioverter‐Defibrillators:

Aetna considers FDA‐approved subcutaneous cardioverter‐ defibrillators medically necessary for persons who meet medical necessity criteria for an implantable cardioverter defibrillator listed above and who do not have symptomatic bradycardia, incessant ventricular tachycardia, or spontaneous, frequently recurring ventricular tachycardia that is reliably terminated with anti‐tachycardia pacing or who have previous endocarditis or infection associated with conventional implantable cardioverter‐ defibrillators.

Aetna considers subcutaneous cardioverter‐defibrillators experimental and investigational for all other indications because their effectiveness and safety have not been established.

Contraindications:

Page 5: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

5 of 44

Cardioverter‐defibrillators are not considered medically necessary when other disease processes are present that clearly and severely limit the member's life expectancy.

Notes: Electronic analysis of defibrillator systems is required for long‐term routine follow‐up care of cardioverter‐defibrillators. Automatic defibrillator monitoring is considered medically necessary. Electrophysiologic assessment is a more complex evaluation of cardioverter‐defibrillators, and is considered medically necessary.

Note: Intracardiac electrophysiological procedures performed before implantation of cardioverter‐defibrillator may be done as an outpatient.

See also CPB 0579 ‐ T‐Wave Alternans (0579.html), and CPB 0610 ‐ Biventricular Pacing (Cardiac Resynchronization Therapy)/Combination Resynchronization‐Defibrillation Devices for Congestive Heart Failure (../600_699/0610.html).

Wearable Cardioverter‐Defibrillators

Aetna considers wearable cardioverter‐defibrillators (WCDs) (automatic external cardioverter‐defibrillators that are worn under the member's clothing) medically necessary durable medical equipment (DME) only for members who meet any of the following criteria:

A documented episode of VF or a sustained (lasting 30 seconds or longer) VT (these dysrhythmias may be either spontaneous or induced during an electrophysiologic (EP) study, but may not be due to a transient or reversible cause and not occur during the first 48 hours of an AMI); or A previously implanted defibrillator now requires explantation; or Member meets above‐listed criteria for an ICD and is awaiting heart transplantation; or Member meets above‐listed criteria for an ICD and has a systemic infectious process or other temporary condition that precludes ICD implantation; or

Page 6: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

6 of 44

Either documented prior myocardial infarction or dilated cardiomyopathy and a measured LVEF less than or equal to 35 %; or Familial or inherited conditions with a high risk of life‐ threatening VT such as long QT syndrome or hypertrophic cardiomyopathy.

Aetna considers WCDs experimental and investigational for use after CABG or PTCA (in persons not meeting any of the above indications) or for other indications because its safety and effectiveness has not been established.

For Aetna's policy on automatic external defibrillators (AEDs) for home use, see CPB 0623 ‐ Safety Items (../600_699/0623.html).

Background Cardiovascular mortality as a consequence of ventricular fibrillation (VF) or ventricular tachycardia (VT) continues to be a major health problem despite advances in the overall management of cardiovascular disease. Sudden cardiac death kills approximately 400,000 people per year. About 10 to 15 % of individuals who experience life threatening VT or VF recover, usually with an external cardiac defibrillator. These survivors have various therapeutic options such as anti‐arrhythmic drugs, radiofrequency or surgical ablation of VT focus, or implantable cardioverter‐defibrillators (ICDs).

Available literature indicates ICDs are now widely used for the secondary prevention of sudden cardiac death due to VF or VT. Ventricular tachycardia or VF can be secondary to a variety of conditions: progression in underlying pathology (i.e., deterioration of left ventricular [LV] function or worsening of coronary artery disease), autonomic imbalance, electrolyte abnormalities or even pharmacological intervention. The ICD is generally accepted as treatment for patients who have experienced an episode of VF not accompanied by an acute myocardial infarction or other transient or reversible causes (e.g., drug toxicity, electrolyte abnormalities, and ischemia). Additionally, accepted guidelines prefer this treatment in patients with sustained VT causing syncope or hemodynamic compromise.

Page 7: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

7 of 44

As primary prevention, the literature shows the ICD is superior to conventional anti‐arrhythmic drug therapy in patients who have survived a myocardial infarction and who have spontaneous, non‐ sustained VT, a low ejection fraction, inducible VT at electrophysiological study, and whose VT is not suppressed by procainamide.

A number of well‐designed studies have shown the effectiveness of the ICD in high‐risk patients who have already experienced a myocardial infarction (MI). Schlapfer and colleagues (2002) compared the long‐term survival rates of patients with sustained ventricular tachyarrhythmia after MI who were treated according to the results of EP study either with amiodarone or an ICD. They found that the long‐term survival of patients with sustained ventricular tachyarrhythmias after MI, with depressed LV function, is significantly better with an ICD than with amiodarone therapy, even when stratified according to the results of the EP study. In a randomized controlled study (n = 1,232) to evaluate the effect of an implantable defibrillator on survival of patients with reduced LV function after MI, Moss et al (2002) concluded that in patients with a prior MI and advanced LV dysfunction, prophylactic implantation of a defibrillator improves survival and should be considered as a recommended therapy.

The Multi‐center Autonomic Defibrillator Implantation Trial II (MADIT II) was stopped early because of a 30 % reduction in mortality in patients randomized to receive an ICD (Coats, 2002). The 4‐year multi‐center trial of 1,200 patients was terminated early after an independent board observed that the post‐MI patients with impaired LV function receiving the implantable defibrillator had improved survival rates compared to those receiving conventional treatment.

The Center for Medicare and Medicaid Services (CMS) determined that the evidence is adequate to conclude that an ICD is reasonable and necessary for the following: (i) patients with ischemic dilated cardiomyopathy (IDCM), documented prior MI, and a measured left ventricular ejection fraction (LVEF) of less than or equal to 35 %; (ii) patients with non‐ischemic dilated cardiomyopathy (NIDCM) greater than 9 months with a measured

Page 8: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

8 of 44

EF less than or equal to 35 %.

In addition, according to CMS, several additional criteria must be met. Patients must not have: New York Heart Association (NYHA) Class IV heart failure; cardiogenic shock or symptomatic hypotension while in a stable baseline rhythm; coronary artery bypass graft or percutaneous transluminal coronary angioplasty within the past 3 months; acute myocardial infarction (AMI) within the past month; clinical symptoms or findings that would make them a candidate for coronary revascularization; irreversible brain damage from pre‐existing cerebral disease; or any disease, other than cardiac disease (e.g., cancer, uremia, liver failure) associated with a likelihood of survival less than 1 year.

The Center for Medicare and Medicaid Services expanded coverage of ICDs to persons with NIDCM, based primarily on the results of the Sudden Cardiac Death in Heart Failure Trial (SCD‐ HeFT), a prospective randomized trial to determine whether amiodarone or an ICD will improve survival compared to placebo in patients with NYHA Class II and Class III heart failure and reduced LVEF less than 35 %. The study included persons with NIDCM and patients with ischemic dilated cardiomyopathy. A total of 2,521 patients were enrolled, 847 of whom were assigned to placebo plus conventional heart failure therapy, 845 to amiodarone plus conventional heart failure therapy, and 829 to single lead ICD plus conventional heart failure therapy. There was a significant reduction in all‐cause mortality in the ICD group compared to the placebo group (hazard ratio compared to control = 0.77; 97.5 % confidence intervals [CI]: 0.62 to 0.96, p = 0.007). For patients with ischemic dilated cardiomyopathy, there was a reduction in mortality hazard ratio compared to control but it was not statistically significant (hazard ratio 0.79; 97.5 % CI: 0.60 to 1.04). For patients with NIDCM, there was a reduction in the mortality hazard ratio for ICD therapy compared to control but it was also not statistically significant (hazard ratio 0.73; 97.5 % CI: 0.50 to1.07). CMS noted that the absolute reduction in mortality was modest for a trial with a median follow‐up of 45.5 months.

Patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) are characterized by

Page 9: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

9 of 44

progressive degeneration of the right ventricular myocardium, ventricular arrhythmias, fibrous‐fatty replacement, and increased risk of sudden death. Mutations in 6 genes, including 4 encoding desmosomal proteins (junctional plakoglobin, desmoplakin, plakophilin 2, and desmoglein 2), have been identified in patients with ARVD/C. The potential use of genetic screening for desmoglein 2 mutations is for identifying persons at increased risk of ARVD/C who are candidates for prophylactic ICD. Currently, there are no prospective studies of the use of desmoglein 2 genetic testing for selecting ICD candidates. About one‐third of individuals with ARVD/C have been reported to have mutations in the desmoglein 2 gene or other associated mutations (Franz et al, 2001), and it is unknown what proportion of asymptomatic persons who have desmoglein 2 mutations go on to develop ARVD/C. Thus, the risks and benefits of prophylactic ICD implantation in persons with mutations of this gene are unknown.

Marenco et al (2001) conducted a systematic review of the literature on the use of automatic external defibrillators (AEDs). Most of the literature on AEDs discusses their use by emergency medical technician or ambulance staff. The authors summarized the literature on use of AEDs by non‐medical persons in the home:

Because the majority of cardiac arrests occur at home, several studies have examined the use of AEDs by family members of high‐risk patients. Although these studies demonstrated the feasibility of training laypersons (e.g., family members) to use an AED, researchers had difficulty with patient recruitment and obtained disappointing results. There is mounting evidence for the efficacy of ICDs in patients at increased risk for sudden cardiac death. This has limited enthusiasm for the placement of AEDs in the home of high‐risk patients and primarily limited the role of the AED in the home to high‐risk patients who either refuse an ICD or have a contraindication to ICD placement. However, these studies used earlier‐generation AEDs and, given the lower costs and ease of use of the current devices, further study with the newer technology is warranted.

An assessment of AEDs for home use by the Canadian

Page 10: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

10 of 44

Coordinating Centre for Health Technology Assessment (CCOHTA) (Murray and Steffensen, 2005) found: “No prospective studies demonstrate that the use of AEDs in the home by untrained persons improves health outcomes. Further investigation is needed to determine the benefit and harm of AEDs in the home”.

Because there are no prospective clinical studies demonstrating that use of AEDs by non‐medical persons for home use improves health outcomes, Aetna considers wearable automatic external cardioverter defibrillators (wearable cardioverter‐defibrillators or WCDs) medically necessary only on an exception basis for high‐ risk patients who meet the criteria for an ICD and who either refuse an ICD or have a contraindication to ICD placement.

Epstein et al (2013) described usage of the WCD during mandated waiting periods following MI for patients perceived to be at high‐ risk for sudden cardiac arrest (SCA). These researchers evaluated characteristics of and outcomes for patients who had a WCD prescribed in the first 3 months post‐MI. The WCD medical order registry was searched for patients who were coded as having had a "recent MI with ejection fraction less than or equal to 35 %" or given an International Classification of Diseases, 9th Revision 410.xx diagnostic code (acute MI), and then matched to device‐ recorded data. Between September 2005 and July 2011, a total of 8,453 unique patients (age of 62.7 ± 12.7 years, 73 % male) matched study criteria. A total of 133 patients (1.6 %) received 309 appropriate shocks. Of these patients, 91 % were resuscitated from a ventricular arrhythmia. For shocked patients, the LVEF was less than or equal to 30 % in 106, 30 % to 35 % in 17, greater than 36 % in 8, and not reported in 2 patients. Of the 38 % of patients not re‐vascularized, 84 % had a LVEF less than or equal to 30 %; of the 62 % of patients re‐vascularized, 77 % had a LVEF less than or equal to 30 %. The median time from the index MI to WCD therapy was 16 days. Of the treated patients, 75 % received treatment in the first month, and 96 % within the first 3 months of use. Shock success resulting in survival was 84 % in non‐re‐vascularized and 95 % in re‐vascularized patients. The authors concluded that during the 40‐day and 3‐month waiting periods in patients post‐MI, the WCD successfully treated SCA in 1.4 %, and the risk was highest in the first month of WCD use.

Page 11: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

11 of 44

The WCD may benefit individual patients selected for high risk of SCA early post‐MI. The main drawback of this observational study was the lack of a control group. Additionally, quality‐of‐life data, cost‐effectiveness and survival were not available in this study.

In an accompanying editorial of the afore‐mentioned study, Zei (2013) stated that “A major limitation to this study is the selection bias inherent in the database used …. Another important limitation of this study is the lack of data about potential arrhythmia under‐detection with the WCD … [T]his study still does not quite answer the elusive question of how to best risk‐ stratify post‐MI low‐EF patients in the early days after infarction”.

In a review on “Wearable cardioverter‐defibrillators”, Adler et al (2013) stated that “The wearable defibrillator was not subjected to such rigorous trials, and it is not clear whether this device will significantly decrease total mortality (and not merely arrhythmic death) in patients with recent MI …. [W]hen the prescription of a wearable defibrillator is being considered, it should be kept in mind that there are no randomized, controlled studies showing that it provides survival benefit”.

The first multi‐center randomized controlled clinical study to examine the use of at‐home AEDs found that the devices do not improve overall survival when compared to conventional resuscitation methods, such as cardiopulmonary resuscitation (CPR). Bardy et al (2008) randomly assigned 7,001 patients with previous anterior‐wall MI who were not candidates for an ICD to receive 1 of 2 responses to sudden cardiac arrest occurring at home: either the control response (calling emergency medical services and performing CPR) or the use of an AED, followed by calling emergency medical services and performing CPR. The primary outcome was death from any cause. The median age of the patients was 62 years; 17 % were women. The median follow‐ up was 37.3 months. Overall, 450 patients died: 228 of 3,506 patients (6.5 %) in the control group and 222 of 3,495 patients (6.4 %) in the AED group (hazard ratio, 0.97; 95 % CI: 0.81 to 1.17; p = 0.77). Mortality did not differ significantly in major pre‐ specified subgroups. Only 160 deaths (35.6 %) were considered to

Page 12: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

12 of 44

be from sudden cardiac arrest from tachyarrhythmia. Of these deaths, 117 occurred at home; 58 at‐home events were witnessed. Automatic external defibrillators were used in 32 patients. Of these patients, 14 received an appropriate shock, and 4 survived to hospital discharge. There were no documented inappropriate shocks. The authors concluded that for survivors of anterior‐wall MI who were not candidates for ICD, access to a home AED did not significantly improve overall survival, as compared with reliance on conventional resuscitation methods.

Exner (2009) stated that most sudden cardiac death (SCD) events occur in patients with less severe LV dysfunction, yet past trials and guidelines focus on those with severe LV dysfunction. Given the large pool of patients with less severe LV dysfunction and a modest risk of SCD, methods to identify those who might benefit from an ICD are needed. Observational studies indicate that abnormal cardiac repolarization and impaired autonomic function, especially in combination, appear to identify patients with less severe LV dysfunction at risk of SCD. Extensive scarring also appears to identify patients at risk. Ongoing and planned studies will better define the role of using non‐invasive tests to select patients for ICD therapy. The author concluded that non‐ invasive measures of cardiac structure, autonomic function and myocardial substrate appear to be promising in identifying patients with less severe LV dysfunction at risk of SCD. However, it is unclear if ICD therapy will improve survival in these patients. Until definitive data from prospective, randomized trials are available it is premature to recommend use of these tools to guide ICD therapy.

Tsai et al (2009) noted that SCD among orthotopic heart transplant recipients is an important mechanism of death after cardiac transplantation. The role for ICDs in this population is not well‐established. These researchers examined if ICDs are effective in preventing SCD in high‐risk heart transplant recipients. They retrospectively analyzed the records of all orthotopic heart transplant patients who had ICD implantation between January 1995 and December 2005 at 5 heart transplant centers. A total of 36 patients were included in this study. The mean age at orthotopic heart transplant was 44 +/‐ 14 years, the majority

Page 13: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

13 of 44

being male (n = 29). The mean age at ICD implantation was 52 +/‐ 14 years, whereas the average time from orthotopic heart transplant to ICD implant was 8 +/‐ 6 years. The main indications for ICD implantation were severe allograft vasculopathy (n = 12), unexplained syncope (n = 9), history of cardiac arrest (n = 8), and severe left ventricular dysfunction (n = 7). Twenty‐two shocks were delivered to 10 patients (28 %), of whom 8 (80 %) received 12 appropriate shocks for either rapid VT or VF. The shocks were effective in terminating the ventricular arrhythmias in all cases. Three (8 %) patients received 10 inappropriate shocks. Underlying allograft vasculopathy was present in 100 % (8 of 8) of patients who received appropriate ICD therapy. The authors concluded that use of ICDs after heart transplantation may be appropriate in selected high‐risk patients. They stated that more studies are needed to establish an appropriate prevention strategy in this population.

The U.S. Food and Drug Administration (FDA) has approved the Subcutaneous Implantable Defibrillator (S‐ICD) System (Cameron Health, San Clemente, CA) "to provide defibrillation therapy for the treatment of life‐threatening ventricular tachyarrhythmias in patients who do not have symptomatic bradycardia, incessant ventricular~tachycardia, or spontaneous, frequently recurring ventricular tachycardia that is reliably terminated with antitachycardia pacing." The Subcutaneous Implantable Defibrillator (S‐ICD) System uses a lead that is implanted just under the skin along the bottom of the rib cage and breast bone. The S‐ICD System consists of: a titanium case containing a battery and electronic circuitry that provides defibrillation therapy and pacing at a rate of 50 beats per minute up to 30 seconds after a shock; a subcutaneous electrode which has a proximal and distal ring electrode on each side of a 3 inch (8 cm) defibrillation coil electrode; and accessories include an electrode insertion tool, programmer, telemetry wand, magnet, suture sleeve, torque wrench, and memory card. The FDA approval was based upon the results of a 321‐patient study in which 304 patients were successfully implanted with the S‐ICD System. At the time of implantation, the investigator tested the effectiveness of the device by inducing heart arrhythmias. The S‐ICD System was successful at converting all abnormal heart rhythms that it

Page 14: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

14 of 44

detected back to normal rhythms. Investigators followed these patients for six months following implantation, during which time the device detected and recorded 78 spontaneous arrhythmias in 21 patients; all arrhythmias were either successfully converted back to normal by the defibrillator or resolved on their own. The FDA noted that, because the S‐ICD System memory stores data from only the 22 most recent arrhythmia episodes, there may have been other detected episodes that could not be analyzed by investigators. The FDA reviewed safety data based on the entire 321‐patient study population to identify complications that can occur during and after implantation of the S‐ICD System. The most common complications included inappropriate shocks, discomfort, system infection, and electrode movement, which required repositioning. The FDA reported that 8 patients died during the study; however, experts (who were not involved with the study) could not definitively attribute the deaths to the S‐ICD System. Eleven patients required the removal of the device, and 18 had discomfort that was resolved without repositioning the device or surgery. At the end of six months, more than 90 percent of patients had no complications. As part of the approval, FDA is requiring the manufacturing company to conduct a postmarket study to assess the long‐term safety and performance of the device and to assess differences in effectiveness across genders. The study will follow 1,616 patients for five years. There is currenty insufficient published evidence of the effectiveness and safety of this device (Bardy et al, 2010; Gold et al, 2012; Jarman et al, 2012; Kobe et al, 2012).

Jarman and Todd (2013) described the early phase United Kingdom (UK) clinical experience with the S‐ICD. A questionnaire was sent to all UK hospitals implanting S‐ICDs. Nineteen of 25 (76 %) hospitals responded with the details of 111 implanted patients (median 5/hospital [range of 1 to 18]). Mean duration of follow‐ up was 12.7 ± 7.1 months. Median patient age was 33 years (range of 10 to 87 years). Underlying pathology was primary electrical disease in 43 %, congenital heart disease 12 %, hypertrophic cardiomyopathy 20 %, ischemic cardiomyopathy 14 %, idiopathic dilated cardiomyopathy 5 %, and other cardiomyopathies 7 % patients. Nineteen (17 %) patients required 20 re‐operations, including permanent device

Page 15: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

15 of 44

explantation in 10 (9 %). Twenty‐four appropriate shocks were delivered in 13 (12 %) patients, including 10 for VF. One patient suffered arrhythmic death, but there were no failures to detect or terminate ventricular arrhythmias above the programmed detection rate. Fifty‐one inappropriate shocks were delivered in 17 (15 %) patients; 41 (80 %) were for T‐wave over‐sensing and 1 (2 %) for atrial flutter‐wave over‐sensing. The 11 patients who received inappropriate shocks due to T‐wave over‐sensing were significantly younger than patients who did not (24 ± 10 versus 37 ± 19 years; p = 0.02). The authors concluded that the S‐ICD is an important innovation in ICD technology. However, these data indicated that adverse event rates were significant during early clinical adoption. Important lessons in patient selection, implant technique, and device programming could be learnt from this experience.

In a prospective, non‐randomized, multi‐center trial, Weiss et al (2013) evaluated the safety and effectiveness of the S‐ICD System for the treatment of life‐threatening ventricular arrhythmias (VT/VF). Adult patients with a standard indication for an ICD, who neither required pacing nor had documented pace‐terminable VT, were included in this study. The primary safety end‐point was the 180‐day S‐ICD System complication‐free rate compared with a pre‐specified performance goal of 79 %. The primary effectiveness end‐point was the induced VF conversion rate compared with a pre‐specified performance goal of 88 %, with success defined as 2 consecutive VF conversions of 4 attempts. Detection and conversion of spontaneous episodes were also evaluated. Device implantation was attempted in 321 of 330 enrolled patients, and 314 patients underwent successful implantation. The cohort was followed for a mean duration of 11 months. The study population was 74 % male with a mean age of 52 ± 16 years and mean LVEF of 36 ± 16 %. A previous transvenous ICD (TV‐ICD) had been implanted in 13 %. Both primary end‐points were met: The 180‐day system complication‐ free rate was 99 %, and sensitivity analysis of the acute VF conversion rate was greater than 90 % in the entire cohort. There were 38 discrete spontaneous episodes of VT/VF recorded in 21 patients (6.7 %), all of which successfully converted. Forty‐one patients (13.1 %) received an inappropriate shock. The authors

Page 16: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

16 of 44

concluded that the findings of this study supported the safety and effectiveness of the S‐ICD System for the treatment of life‐ threatening ventricular arrhythmias. The main drawbacks of this study were the lack of a control group and the short duration of the follow‐up.

In an accompanying editorial of the afore‐mentioned study, Saxon noted that “Over the follow‐up interval reported in this study, the subcutaneous ICD terminated spontaneously occurring VT/VF in 6.5 % of the patients implanted (21 patients). There were a total of 22 episodes of spontaneously occurring monomorphic VT and 16 episodes of VF treated. First and second shock success rate was 92 % and 97 %, respectively. Two patients had multiple successful shocks for VT storm. Although these data are reassuring and comparable to TV‐ICD success rates, the overall number of treated episodes is incredibly small in comparison with the data on transvenous defibrillator therapies delivered outside the hospital, over the life of the device, that are available for analysis in tens of thousands of patients. Without the ability to remotely collect episodes in all subcutaneous device recipients, it is difficult to know how the learning around spontaneous VT/VF episodes and treatment will occur, other than the old‐fashioned way, through case reports and post‐approval registries. This is a significant limitation from a clinical learning and safety advisory perspective …. Without remote monitoring capability, it will be difficult to track the occurrences of these episodes in the population of patients who receive the subcutaneous ICD. This is concerning, because the population enrolled in the subcutaneous ICD study were 10 to 20 years younger than the standard transvenous ICD recipient. The age of the subcutaneous ICD recipients indicates that they may be a more active and more prone to over‐sensing owing to subcutaneous sensing challenges or T‐wave double counting …. Although the subcutaneous ICD is de‐featured and exists only to defibrillate, it does represent a major engineering feat for an entirely subcutaneous system. Yet, the most profound technology advances in the past decades, particularly in the case of devices, allow for an enhancement of capability (and complexity) to the backend architecture and a simplification of design features and user interface. The subcutaneous ICD does not encompass these features nearly as

Page 17: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

17 of 44

much as the transvenous device. In the best of all possible worlds, the subcutaneous ICD will grow and evolve into a device whose design supports the growth of features and capabilities that can evolve with the patient’s condition. This includes integrating wirelessly with other hardware‐ and software‐based healthcare solutions that will enhance the device and the device recipient's overall medical condition. The enhancements will provide multiple reasons for subcutaneous ICD to exist”.

Akerstrom et al (2013) stated that the S‐ICD has recently been approved for commercial use in Europe, New Zealand and the United States. It is comprised of a pulse generator, placed subcutaneously in a left lateral position, and a parasternal subcutaneous lead‐electrode with 2 sensing electrodes separated by a shocking coil. Being an entirely subcutaneous system it avoids important peri‐procedural and long‐term complications associated with transvenous implantable cardioverter‐ defibrillator (TV‐ICD) systems as well as the need for fluoroscopy during implant surgery. Suitable candidates include pediatric patients with congenital heart disease that limits intra‐cavitary lead placements, those with obstructed venous access, chronic indwelling catheters or high infection risk, as well as young patients with electrical heart disease (e.g., Brugada Syndrome, long QT syndrome, and hypertrophic cardiomyopathy). Nevertheless, given the absence of intra‐cavitary leads, the S‐ICD is unable to offer pacing (apart from short‐term post‐shock pacing). It is therefore not suitable in patients with an indication for anti‐bradycardia pacing or cardiac resynchronization therapy, or with a history of repetitive monomorphic VT that would benefit from anti‐tachycardia pacing. Current data from initial clinical studies and post‐commercialization "real‐life" case series, including over 700 patients, have so far been promising and shown that the S‐ICD successfully converts induced and spontaneous VT/VF episodes with associated complication and inappropriate shock rates similar to that of TV‐ICDs. Furthermore, by using far‐field electrograms better tachyarrhythmia discrimination when compared to TV‐ICDs has been reported. The authors concluded that future results from ongoing clinical studies will determine the S‐ICD system's long‐ term performance, and better define suitable patient profiles.

Page 18: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

18 of 44

Pettit et al (2013) compared the performance of S‐ICD and TV‐ICD systems in children and teenagers. These researchers studied consecutive patients less than 20 years of age who received an ICD over a 4‐year period in 2 Scottish centers. Baseline characteristics, complications, and ICD therapy were recorded. The primary outcome measure was survival. The secondary outcome measure was survival‐free from inappropriate ICD therapy or system revision. A total of 9 S‐ICD were implanted in 9 patients; 8 TV‐ICD were implanted in 6 patients; 2 were redo procedures. Baseline characteristics were well‐matched. Median duration of follow‐up was lower for S‐ICD (20 months) than for TV‐CD (36 months, p = 0.0262). Survival was 100 % in both groups. Survival free of inappropriate therapy or system revision was 89 % for S‐ICD and 25 % for TV‐ICD systems (log‐rank test, p = 0.0237). No S‐ICD were extracted, but 3 TV‐ ICD were extracted due to infection (n = 1) and lead failure (n = 2). The authors concluded that in real‐world use in children and teenagers, S‐ICD may offer similar survival benefit to TV‐CD, with a lower incidence of complications requiring reoperation. They stated that in the absence of randomized trials, S‐ICD should be compared prospectively with TV‐ICD in large multi‐center registries with comparable periods of follow‐up.

Majithia et al (2014) noted that randomized clinical trials support the use of implantable defibrillators for mortality reduction in specific populations at high‐risk for sudden cardiac death. Conventional transvenous defibrillator systems are limited by implantation‐associated complications, infection, and lead failure, which may lead to delivery of inappropriate shocks and diminish survival. The development of a fully subcutaneous defibrillator may represent a valuable addition to therapies targeted at sudden death prevention. The PubMed database was searched to identify all clinical reports of the subcutaneous defibrillator from 2000 to the present. These investigators reviewed all case series, cohort analyses, and randomized trials evaluating the safety and effectiveness of subcutaneous defibrillators. The subcutaneous defibrillator is a feasible development in sudden cardiac death therapy and may be useful particularly to extend defibrillator therapy to patients with complicated anatomy, limited vascular access, and congenital disease. The

Page 19: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

19 of 44

subcutaneous defibrillator should not be considered in patients with an indication for cardiac pacing or who have VT responsive to anti‐tachycardia pacing. The authors concluded that further investigation is needed to compare long‐term, head‐to‐head performance of subcutaneous defibrillators and conventional transvenous defibrillator systems.

Furthermore, the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines on “The management of ST‐elevation myocardial infarction” (O’Gara et al, 2013) mentioned ICD therapy; but not subcutaneous ICD.

Previous Endocarditis or Device Infection as an Indication for Subcutaneous Defibrillator:

De Maria et al (2014) stated the following regarding implanted and subcutaneous defibrillator: http://www.escardio.org /communities/councils/ccp/e‐journal/volume12/Pages /subcutaneous‐defibrillator‐who‐may‐benefit‐demaria‐olaru‐ cappeli.aspx (http://www.escardio.org/communities/councils /ccp/e‐journal/volume12/Pages/subcutaneous‐defibrillator‐ who‐may‐benefit‐demaria‐olaru‐cappeli.aspx).

Implantable cardioverter‐defibrillator: Insertion of the electrode into the central venous circulation and inside cardiac chambers can cause vascular obstruction, thrombosis, infection and cardiac perforation. Moreover, lead failure has been estimated at 0.58 %/year and up to 20 % at 10 years; failures may require the leads to be extracted, however this is a highly challenging procedure: major complications rates are about 1 % and mortality is at 0.3 %, even in experienced centers. Subcutaneous defibrillator: The risk of systemic infections appears to be very low, best in high‐risk cases of previous device infection, hemodialysis, chronic immunosuppression therapy immunodeficiencies, or artificial heart valves.

Subcutaneous defibrillator as first choice ‐‐ Previous endocarditis or device infection

Page 20: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

20 of 44

Also, an UpToDate review on “Subcutaneous implantable cardioverter defibrillators” (Weinstock et al, 2015) states that “ICD systems consist of a pulse generator, typically placed in the pectoral region, and one or more leads which attach the pulse generator to the heart, most commonly to the endocardium via transvenous insertion. However, conventional transvenous ICD (TV‐ICD) systems come with the inherent drawbacks of transvenous leads, including:

Risks at the time of insertion ‐‐ Cardiac perforation, pericardial effusion, cardiac tamponade, hemothorax, pneumothorax Delayed risks over the lifetime of the device ‐‐ Intravascular lead infection, lead failure

Reports of complications at the time of TV‐ICD range from 3 to 6 % of implants. In addition, the delayed risks of transvenous leads include a risk of infection (incidence of 9 per 1,000 device‐years) and lead failure (ranging from 5 to 40 %of leads at 5 years depending on the type of lead), both of which lead to repeat procedures and increased morbidity for patients …. The subcutaneous implantable cardioverter defibrillator (S‐ICD) system obviates some of the mechanical complications associated with transvenous lead implantation (e.g., cardiac perforation leading to pericardial effusion and cardiac tamponade, hemothorax, pneumothorax, endovascular lead infection)”.

Defibrillation Threshold (DFT) Testing During Implantable Cardioverter‐Defibrillator Implantation:

Gula et al (2008) noted that defibrillation threshold (DFT) testing is generally performed during implantation of ICDs to assess sensing and termination of VF. It is common clinical practice to defibrillate VF twice at an output at least 10 J below the maximum output of the device, providing a 10 J safety margin. However, there are few data regarding impact of DFT testing on outcomes. These investigators evaluated the impact of DFT testing of implanted ICDs on survival. Decision analysis and Monte Carlo simulation were used to assess expected outcomes of DFT testing. Survival of a hypothetical cohort of patients was assessed according to 2 strategies‐routine DFT testing at time of

Page 21: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

21 of 44

ICD implant versus no DFT testing. Assumptions in the model were varied over a range of reasonable values to assess outcomes under a variety of scenarios. Five‐year survival rates with DFT and no‐DFT strategies were similar at 59.72 % and 59.36 %, respectively. The results were not sensitive to changing risk estimates for arrhythmia incidence and safety margin. Results of the Monte Carlo simulation were qualitatively similar to the base case scenario and consistent with a small and non‐significant survival advantage with routine DFT testing. The authors concluded that the impact of DFT testing on 5‐year survival in ICD patients, if it exists, is small. Survival appears higher with DFT testing as long as annual risk of lethal arrhythmia or the risk of a narrow safety margin is at least 5 %, although the incremental benefit is marginal and 95 % CIs cross zero. They stated that a prospective randomized study of DFT testing in modern devices is warranted.

Bianchi et al (2009) compared the outcome of ICD recipients who underwent DFT testing with that of patients in whom no testing was performed. A total of 291 subjects with ischemic dilated cardiomyopathy received transvenous ICDs between January 2000 and December 2004 in 5 Italian cardiology centers were included in this study. In 2 centers, DFT testing was routinely performed in 137 patients (81 % men; mean age of 69 +/‐ 9 years; mean ejection fraction of 26 +/‐ 4 %) (DFT group), while 3 centers never performed DFT testing in 154 patients (90 % men; mean age of 69 +/‐ 9 years; mean ejection fraction of 27 +/‐ 5 %) (no‐ DFT group). These researchers compared total mortality, total cardiovascular mortality, SCD, and spontaneous episodes of ventricular arrhythmia (sustained ventricular tachycardia, VT, and ventricular fibrillation, VF) between these groups 2 years after implantation (median of 23 months; 25th to 75th percentile; 12 to 44 months). On comparing the DFT and no‐DFT groups, these investigators found an overall mortality rate of 20 % versus 16 %, cardiovascular mortality of 13 % versus 10 %, SCD of 3 % versus 1.6 %, VT incidence of 8 % versus 10 %, and VF incidence of 6 % versus 4 % (no significant difference in any comparison). The authors concluded that no significant differences in the incidence of clinical outcomes considered emerged between no‐DFT and DFT groups. They stated that these results should be confirmed

Page 22: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

22 of 44

in larger prospective studies.

Stefano et al (2011) stated that clinical practice with regard to DFT testing during ICD implantation varies considerably, even among experienced implanting centers. International guidelines do not as yet mandate DFT testing. These investigators evaluated current clinical decision making regarding DFT testing during ICD implantation. The ALIVE project collected data on DFT testing from a multi‐center network of Italian clinicians sharing a common system for the collection, management, analysis, and reporting of clinical and diagnostic data from patients with Medtronic (Minneapolis, MN) implantable devices. Data on 2,082 consecutive patients implanted with a Medtronic ICD in 111 Italian centers, over the period 2007 to 2010, were analyzed. Defibrillation threshold testing was performed in 33 % of cases

(678/2,082). The main reasons for performing the test were physician's clinical practice ("I always perform DFT") (80 %) and secondary prevention implantation (12 %). The main reasons for not performing DFT testing were centers' practice (44 %), primary prevention (31 %), and device replacement (15 %). In 22 patients, VF induction was not achieved; 656 patients completed DFT testing: 633 patients (96 %) performed a single test, 19 patients (3 %) performed a second induction test, and 4 patients (0.6 %) underwent an additional induction test. The authors concluded that the preliminary results of the ALIVE project showed that a great number of implant procedures were performed without DFT testing in the common practice of the participating centers. They also measured an inhomogeneous, center‐dependent DFT testing behavior, which suggested the importance of defining a common guideline for ICD implant testing. They stated that follow‐up data on these patients will provide more information on the clinical value of the test.

Russo and Chung (2014) noted that with advancements in ICD technology, the practice of performing DFT testing at the time of implantation has been questioned. With availability of biphasic waveforms, active cans, and high‐output devices, opponents claim that DFT testing is no longer necessary. Clinical trials demonstrating the effectiveness of ICDs in prevention of SCD have, however, all used some form of defibrillation testing. This

Page 23: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

23 of 44

debate is fueled by the absence of data from randomized prospective trials evaluating the role of DFT testing in predicting clinical shock efficacy or survival.

In a single‐blind, randomised, multi‐center, non‐inferiority clinical trial (Shockless IMPLant Evaluation [SIMPLE]), Healey et al (2015) compared the safety and effectiveness of ICD implantation without DFT testing versus the standard of ICD implantation with DFT testing. These investigators recruited patients aged older than 18 years receiving their first ICD for standard indications at 85 hospitals in 18 countries worldwide. Exclusion criteria included pregnancy, awaiting transplantation, participation in another randomised trial, unavailability for follow‐up, or if it was expected that the ICD would have to be implanted on the right‐ hand side of the chest. Patients undergoing initial implantation of a Boston Scientific ICD were randomly assigned (1:1) using a computer‐generated sequence to have either DFT (testing group) or not (no‐testing group). These researchers used random block sizes to conceal treatment allocation from the patients, and randomization was stratified by clinical center. The primary efficacy analysis tested the intention‐to‐treat population for non‐ inferiority of no‐testing versus testing by use of a composite outcome of arrhythmic death or failed appropriate shock (i.e., a shock that did not terminate a spontaneous episode of ventricular tachycardia or fibrillation). The non‐inferiority margin was a hazard ratio (HR) of 1.5 calculated from a proportional hazards model with no‐testing versus testing as the only covariate; if the upper bound of the 95 % CI was less than 1.5. These investigators concluded that ICD insertion without testing

was non‐inferior to ICD with testing. They examined safety with 2, 30‐day, adverse event outcome clusters. Between Jan 13, 2009, and April 4, 2011, of 2,500 eligible patients, 1,253 were randomly assigned to defibrillation testing and 1,247 to no‐ testing, and followed‐up for a mean of 3.1 years (SD 1.0). The primary outcome of arrhythmic death or failed appropriate shock occurred in fewer patients (90 [7 % per year]) in the no‐testing group than patients who did receive it (104 [8 % per year]; HR 0.86, 95 % CI: 0.65 to 1.14; p (non‐inferiority) < 0.0001). The first safety composite outcome occurred in 69 (5.6 %) of 1,236 patients with no‐testing and in 81 (6.5 %) of 1,242 patients with

Page 24: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

24 of 44

defibrillation testing, p = 0∙33. The second, pre‐specified safety composite outcome, which included only events most likely to be directly caused by testing, occurred in 3.2 % of patients with no‐ testing and in 4.5 % with defibrillation testing, p = 0∙08. Heart failure needing intravenous treatment with inotropes or diuretics was the most common adverse event (in 20 [2 %] of 1,236 patients in the no‐testing group versus 28 [2 %] of 1,242 patients in the testing group, p = 0∙25). The authors concluded that routine defibrillation testing at the time of ICD implantation is generally well‐tolerated, but does not improve shock efficacy or reduce arrhythmic death.

Implantable Cardioverter‐Defibrillator Use in Patients With Left Ventricular Assist Devices:

Enriquez and co‐workers (2013) noted that the prognosis for patients experiencing ventricular arrhythmias (VAs) while on continuous flow LVAD support has not been well elucidated. Accordingly, the role of ICDs in this patient population remains undefined. Records of 106 consecutive patients undergoing implantation of the HeartMate II LVAD at a single center were reviewed. For patients surviving greater than 30 days post‐ implant (98 patients), the impact of VAs and ICDs on survival was analyzed. Mean age was 56.6 ± 11.4 years, 82.1 % were male, 42.5 % had an ischemic cardiomyopathy, 87.7 % were bridge to transplantation (BT), and median length of support was 217 days. A total of 21 (19.8 %) patients died, 60 (56.6 %) survived to transplantation, and 25 patients (23.6 %) reached the end of study, had the LVAD explanted, or were lost to follow‐up. Post‐ LVAD VAs occurred in 37 patients (34.9 %); but were not associated with increased mortality (HR, 0.58 [0.18 to 1.90]); 62 (63.3 %) patients had an active ICD, and 36 (36.7 %) patients had no ICD or an inactivated ICD post‐LVAD. Patients with an ICD were more likely to be INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) level 3 or 4 at the time of implant (54.8 % versus 33.3 %; p = 0.04). An appropriate shock was delivered in 27.3 % of patients, but the presence of an active ICD was not associated with improved survival (HR, 1.12 [0.37 to 3.35]). The authors concluded that VAs were common in patients with continuous flow LVADs. Although some episodes may be

Page 25: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

25 of 44

clinically significant, VAs were not associated with a worse prognosis, and concomitant ICDs in these patients may not reduce mortality.

In a systematic review and meta‐analysis, Va kil and colleagues (2016) evaluated the impact of (ICDs on mortality in patients with left ventricular assist devices (LVADs). Relevant studies from January 2000 through October 2015 were identified in the databases PubMed and OVID. Weighted relative risks were estimated using random effects meta‐analysis techniques. A total of 6 observational studies (n = 937) were included. Patients were 53 ± 12 years of age, and 80 % were male; BT was the indication for LVAD use in 93 % of the patients. A continuous‐flow (CF) LVAD was present in 39 % of patients. Mean LV EF was 16 ± 6 %. An ICD was present in 355 patients (38 %). During a mean follow‐up of 7 months, 241 patients (26 %) died (16 % in the ICD group versus 32 % in the no‐ICD group). Presence of an ICD was associated with a 39 % relative risk reduction in all‐cause mortality (relative risk [RR]: 0.61; 95 % CI: 0.46 to 0.82; p < 0.01). Among subgroup of patients with CF‐LVAD (n = 361), ICD use was associated with a statistically non‐significant trend toward improved survival (RR: 0.76; 95 % CI: 0.51 to 1.12; p = 0.17). The authors concluded that ICD use was associated with a significant reduction in mortality in LVAD patients, however, this effect was not significant in patients with CF‐LVADs. They stated that although these data support the use of ICDs, larger randomized trial data are strongly needed to evaluate ICD effectiveness in patients with current generation LVADs.

Agrawal and associates (2016) evaluated the impact of presence of ICD on mortality in continuous flow LVAD recipients. A meta‐ analysis of available literature was performed. PubMed, Embase and Google Scholar databases were searched for studies that compared mortality in continuous flow LVAD patients with ICDs (new implantation or no de‐activation) and without ICDs (including de‐activation of existing implant). Pooled analysis using a fixed effects model was used for outcomes of interest. These investigators included 3 observational studies for a total of 292 patients (203 (69.5 %) with ICD versus 89 (30.5 %) without ICD). The presence of an active ICD was not associated with

Page 26: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

26 of 44

improved survival [odds ratio [OR] 0.63, 95 % CI: 0.33 to 1.18; p = 0.15]. In BT patients (224 patients, 149 with ICD versus 75 without ICD), an active ICD was not associated with a higher probability of survival [OR 1.47, 95 % CI: 0.78 to 2.76; p = 0.23]. There was no difference in the occurrence of severe right ventricular dysfunction or failure between 2 groups [OR 0.78, 95 % CI: 0.42 to 1.47; p = 0.45]. The risk of LVAD related complications were similar [OR 0.68, 95 % CI: 0.35 to 1.31; p = 0.25]. The authors concluded that this meta‐analysis demonstrated that there is no survival benefit with ICD in heart failure patients supported with continuous flow LVAD. They stated that there is an urgent need of large‐scale randomized trials to specifically address this issue.

Appendix

New Yo rk Heart Association Functional Classification of Cardiac Disability:

Class I: Patients with cardiac disease but without resulting limitations of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, dyspnea, or anginal pain.

Class II: Patients with cardiac disease resulting in slight limitation of physical activity. They are comfortable at rest. Ordinary physical activity results in fatigue, palpitation, dyspnea, or anginal pain.

Class III: Patients with cardiac disease resulting in marked limitation of physical activity. They are comfortable at rest. Less than ordinary physical activity causes fatigue, palpitation, dyspnea, or anginal pain.

Class IV: Patients with cardiac disease resulting in inability to carry on any physical activity without discomfort. Symptoms of cardiac insufficiency or of the anginal syndrome may be present even at rest. If any physical activity is undertaken, discomfort is increased.

Source: Adapted from Goldman et al (1981).

Page 27: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

27 of 44

CPT Codes / HCPCS Codes / ICD‐10 Codes

Information in the [brackets] below has been added for clarification

purposes. Codes requiring a 7th character are represented by "+":

Implantable Cardioverter‐Defibrillators:

CPT codes covered if selection criteria are met:

33216 Insertion of a single transvenous electrode, permanent

pacemaker or implantable defibrillator

33217 Insertion of 2 transvenous electrodes, permanent

pacemaker or implantable defibrillator

33218 Repair of single transvenous electrode, permanent

pacemaker or implantable defibrillator

33220 Repair of 2 transvenous electrodes for permanent

pacemaker or implantable defibrillator

33223 Relocation of skin pocket for implantable defibrillator

33224 Insertion of pacing electrode, cardiac venous system,

for left ventricular pacing, with attachment to previously placed pacemaker or implantable

defibrillator pulse generator (including revision of pocket, removal, insertion, and/or replacement of

existing generator)

33225 Insertion of pacing electrode, cardiac venous system,

for left ventricular pacing, at time of insertion of

implantable defibrillator or pacemaker pulse generator (eg, for upgrade to dual chamber system) (List

separately in addition to code for primary procedure)

33226 Repositioning of previously implanted cardiac venous

system (left ventricular) electrode (including removal, insertion and/or replacement of existing generator)

33230 Insertion of implantable defibrillator pulse generator

only; with existing dual leads

33231 with existing multiple leads

33240 Insertion of implantable defibrillator pulse generator

only; with existing single lead

33241 Removal of implantable defibrillator pulse generator

only

Page 28: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

28 of 44

33243 Removal of single or dual chamber implantable defibrillator electrode(s); by thoracotomy

33244 by transvenous extraction

33249 Insertion or replacement of permanent implantable defibrillator system, with transvenous lead(s), single or

dual chamber

33262 Removal of implantable defibrillator pulse generator with replacement of implantable defibrillator pulse generator; single lead system

33263 dual lead system

33264 multiple lead system

93741 Electronic analysis of pacing cardioverter‐defibrillator

(includes interrogation, evaluation of pulse generator status, evaluation of programmable parameters at rest

and during activity where applicable, using electrocardiographic recording and interpretation of

recordings at rest and during exercise, analysis of event markers and device response); single chamber

or wearable cardioverter‐defibrillator system, without reprogramming

93742 Electrophysiologic evaluation of single or dual

chamber transvenous pacing cardioverter‐defibrillator (includes defibrillation threshold evaluation, induction

of arrhythmia, evaluation of sensing and pacing for arrhythmia termination, and programming or

reprogramming of sensing or therapeutic parameters)

93743 dual chamber, without reprogramming

93744 dual chamber, with reprogramming

93745 Initial set‐up and programming by a physician of wearable cardioverter‐defibrillator includes initial

programming of ssytem, establishing baseline electronic ECG, transmission of data to data repository,

patient instruction in wearing system and patient reporting of problems or events

Other CPT codes related to the CPB:

Page 29: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

29 of 44

93640 Electrophysiologic evaluation of single or dual chamber pacing cardioverter‐defibrillator leads

including defibrillation threshold evaluation (induction of arrhythmia, evaluation of sensing and pacing for

arrhythmia termination) at time of initial implantation or replacement;

93641 with testing of single or dual chamber pacing

cardioverter‐defibrillator pulse generator

93642 Electrophysiologic evaluation of single or dual chamber pacing cardioverter‐defibrillator (includes

defibrillation threshold evaluation, induction of arrhythmia, evaluation of sensing and pacing for

arrhythmia termination, and programming or reprogramming of sensing or therapeutic parameters)

HCPCS codes covered if selection criteria are met:

C1721 Cardioverter‐defibrillator, dual chamber (implantable)

C1722 Cardioverter‐defibrillator, single chamber (implantable)

C1777 Lead, cardioverter‐defibrillator, endocardial single coil

(implantable)

C1882 Cardioverter‐defibrillator, other than single or dual

chamber (implantable)

C1895 Lead, cardioverter‐defibrillator, endocardial dual coil (implantable)

C1896 Lead, cardioverter‐defibrillator, other than endocardial single or dual coil (implantable)

C1899 Lead, pacemaker/cardioverter‐defibrillator combination (implantable)

G0448 Insertion or replacement of a permanent pacing cardioverter‐defibrillator system with transvenous

lead(s), single or dual chamber with insertion of pacing electrode, cardiac venous system, for left ventricular

pacing

K0606 Automatic external defibrillator, with integrated

electrocardiogram analysis, garment type

HCPCS codes not covered for indications listed in the CPB:

Page 30: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

30 of 44

E0617 External defibrillator with integrated electrocardiogram analysis

Other HCPCS code related to the CPB:

J0282 Injection, amiodarone HCL, 30 mg

ICD‐10 codes covered if selection criteria are met:

A00.0 –

B99.9

Certain infectious and parasitic disease [systemic

infectious process]

D86.85 Sarcoid myocarditis

I40.1 Isolated myocarditis

I42.1 ‐ I42.1 Obstructive and other hypertrophic cardiomyopathy

I42.8 ‐ I42.9 Other and unspecified cardiomyopathies [arrhythmogenic right ventricular cardiomyopathy

(ARVC)] [ LV non‐compaction cardiomyopathy]

I46.2 ‐ I46.9 Cardiac arrest

I47.1 Supraventricular tachycardia

I47.2 Ventricular tachycardia [catecholaminergic polymorphic]

I47.9 Paroxysmal tachycardia, unspecified

I49.01 Ventricular fibrillation

I49.02 Ventricular flutter

Q24.8 Other specified congenital malformations of heart

[Brugada syndrome]

T82.110+ ‐ T82.199+

Mechanical complication of cardiac electronic device

T82.6xx+ ‐

T82.7xx+

Infection and inflammatory reaction due to cardiac

device, implant, and graft

Z45.02 Encounter for adjustment and management of automatic implantable cardiac defibrillator

Z76.82 Awaiting organ transplant status [awaiting heart

transplant]

Subcutaneous cardioverter‐defibrillators:

CPT codes covered if selection criteria are met:

Page 31: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

31 of 44

33270 Insertion or replacement of permanent subcutaneous implantable defibrillator system, with subcutaneous

electrode, including defibrillation threshold evaluation, induction of arrhythmia, evaluation of sensing for

arrhythmia termination, and programming or reprogramming of sensing or therapeutic parameters,

when performed

33271 Insertion of subcutaneous implantable defibrillator

electrode

33272 Removal of subcutaneous implantable defibrillator electrode

33273 Repositioning of previously implanted subcutaneous implantable defibrillator electrode

93260 ‐ Programming device evaluation (in person) with 93261 iterative adjustment of the implantable device to test

the function of the device and select optimal

permanent programmed values with analysis, review and report by a physician or other qualified health care

professional

93644 Electrophysiologic evaluation of subcutaneous implantable defibrillator (includes defibrillation

threshold evaluation, induction of arrhythmia, evaluation of sensing for arrhythmia termination, and

programming or reprogramming of sensing or therapeutic parameters)

HCPCS codes covered if selection criteria are met:

C1882 Cardioverter‐defibrillator, other than single or dual chamber (implantable) [subcutaneous cardioverter‐

defibrillators]

ICD‐10 codes covered if selection criteria are met:

B57.0, B57.2 Chagas disease with heart involvement

D86.89 Sarcoidosis of other sites [cardiac]

I01.1 ‐ I01.2 Acute rheumatic endocarditis

I33.0 ‐ I33.9 Acute and subacute endocarditis

I38 Endocarditis, valve unspecified

I40.1 Isolated myocarditis

Page 32: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

32 of 44

I42.1 Obstructive hypertrophic cardiomyopathy

I42.2 Other hypertrophic cardiomyopathy

I42.8 Other cardiomyopathies [arrhythmogenic right ventricular cardiomyopathy (ARVC)][ LV non‐

compaction cardiomyopathy]

I49.01 ‐

I49.02

Ventricular fibrillation and flutter

I46.2 ‐ I46.9 Cardiac arrest

Q24.8 Other specified congenital malformations of heart [Brugada syndrome]

T82.110+ ‐ T82.119+

Mechanical complication of cardiac prosthetic devices implants and grafts

T82.6xx+ ‐ T82.7xx+

Infection and inflammatory reaction due to other cardiac devices, implants and grafts

Z45.02 Fitting and adjustment of automatic implantable cardiac defibrillator

ICD‐10 codes not covered for indications listed in the CPB:

I47.0 ‐ I47.9 Paroxysmal tachycardia [not covered for incessant

ventricular tachycardia, or spontaneous, frequently recurring ventricular tachycardia that is reliably

terminated with anti‐tachycardia pacing]

R00.1 Bradycardia, unspecified [symptomatic]

The above policy is based on the following references: 1. Dreifus LS, Fisch C, Griffin JC, et al. Guidelines for

implantation of cardiac pacemakers and antiarrhythmia devices. A report of the American College of Cardiology / American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures. J Am Coll Cardiol. 1991;18(1):1‐13; Circulation. 1991;84(1):455‐467.

2. Yurchak PM, Williams SV, Achord JL, et al. Clinical competence in elective direct current (DC) cardioversion. A statement for physicians from the ACP/ACC/AHA Task Force

Page 33: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

33 of 44

on Clinical Privileges in Cardiology. Circulation. 1993;88(1):342‐345.

3. Saksena S, Epstein AE, Lazzara R, et al. Clinical investigation of antiarrhythmic devices. A statement for healthcare professionals from a joint task force of the American Heart Association, the North American Society of Pacing and Electrophysiology, the American College of Cardiology, and the Working Groups on Arrhythmias and Cardiac Pacing of the European Society of Cardiology. J Am Coll Cardiol. 1995;25(5):961‐973; Circulation. 1995;91(7):2097‐2109.

4. Friedman PL, Stevenson WG. Unsustained ventricular tachycardia ‐‐ to treat or not to treat? N Engl J Med. 1996;335(26):1984‐1985.

5. Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933‐1940.

6. Owens DK, Sanders GD, Harris RA, et al. Cost‐effectiveness of implantable cardioverter defibrillators relative to amiodarone for prevention of sudden cardiac death. Ann Intern Med. 1997;126(1):1‐12.

7. Raviele A. Implantable cardioverter‐defibrillator (ICD) indications in 1996: Have they changed? Am J Cardiol. 1996;78(5A):21‐25.

8. Greene HL. The implantable cardioverter‐defibrillator. Clin Cardiol. 2000;23(5):315‐326.

9. Stanton MS, Bell GK. Economic outcomes of implantable cardioverter‐defibrillators. Circulation. 2000;101(9):1067‐1074.

10. Eckardt L, Haverkamp W, Johna R, et al. Arrhythmias in heart failure: Current concepts of mechanisms and therapy. J Cardiovasc Electrophysiol. 2000;11(1):106‐117.

11. Bocka J. Automatic external defibrillation. eMedicine J. 2001;2(3). Available at: http://www.emedicine.com /emerg/topic698.htm (http://www.emedicine.com /emerg/topic698.htm). Accessed April 3, 2002.

12. Eisenberg MS, Moore J, Cummins RO, et al. Use of the automatic external defibrillator in homes of survivors of out‐of‐hospital ventricular fibrillation. Am J Cardiol.

Page 34: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

34 of 44

1989;63(7):443‐446. 13. Moore JE, Eisenberg MS, Andresen E, et al. Home

placement of automatic external defibrillators among survivors of ventricular fibrillation. Ann Emerg Med. 1986;15(7):811‐812.

14. Cummins RO, Eisenberg MS, Bergner L, et al. Automatic external defibrillation: Evaluations of its role in the home and in emergency medical services. Ann Emerg Med. 1984;13(9 Pt 2):798‐801.

15. Marenco JP, Wang PJ, Link MS, et al. Improving survival from sudden cardiac arrest: The role of the automated external defibrillator. JAMA. 2001;285(9):1193‐1200.

16. McDaniel CM, Berry VA, Haines DE, et al. Automatic external defibrillation of patients after myocardial infarction by family members: Practical aspects and psychological impact of training. Pacing Clin Electrophysiol. 1988;11(11 Pt 2):2029‐2034.

17. Cannom DS. Implantable cardioverter defibrillator trials: What's new? Curr Opin Cardiol. 2002;17(1):29‐35.

18. Schlapfer J, Rapp F, Kappenberger L, et al. Electrophysiologically guided amiodarone therapy versus the implantable cardioverter‐defibrillator for sustained ventricular tachyarrhythmias after myocardial infarction: Results of long‐term follow‐up. J Am Coll Cardiol. 2002;39(11):1813‐1819.

19. Coats AJ. MADIT II, the Multi‐center Autonomic Defibrillator Implantation Trial II stopped early for mortality reduction, has ICD therapy earned its evidence‐based credentials? Int J Cardiol. 2002;82(1):1‐5.

20. Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877‐883.

21. Swygman C, Wang PJ, Link MS, et al. Advances in implantable cardioverter defibrillators. Curr Opin Cardiol. 2002;17(1):24‐28.

22. BlueCross BlueShield Association (BCBSA), Technology Evaluation Center (TEC). Use of implantable cardioverter‐ defibrillators for prevention of sudden death in patients at high risk for ventricular arrhythmia. TEC Assessment

Page 35: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

35 of 44

Program. Chicago, IL: BCBSA; August 2002;17(10). Available at: http://www.bcbs.com/tec/vol17/17_10.html. Accessed February 21, 2005.

23. Boehmer JP. Device therapy for heart failure. Am J Cardiol. 2003;91(6A):53D‐59D.

24. Gillis AM, Philippon F, Cassidy MR, et al. Guidelines for implantable cardioverter defibrillator follow‐up in Canada: A consensus statement of the Canadian Working Group on Cardiac Pacing. Can J Cardiol. 2003;19(1):21‐37.

25. Ezekowitz JA, Armstrong PW, McAlister FA. Implantable cardioverter defibrillators in primary and secondary prevention: A systematic review of randomized, controlled trials. Ann Intern Med. 2003;138(6):445‐452.

26. Bradley DJ, Bradley EA, Baughman KL, et al. Cardiac resynchronization and death from progressive heart failure: A meta‐analysis of randomized controlled trials. JAMA. 2003;289(6):730‐740.

27. Center for Medicare Services and Medicaid Services (CMS), Medicare Coverage Advisory Committee. Implantable defibrillators in the primary prevention of sudden cardiac death. Summary of the evidence. Baltimore, MD: CMS; February 11, 2003. Available at: http://cms.hhs.gov /mcd/viewtrackingsheet.asp?id=39 (http://cms.hhs.gov /mcd/viewtrackingsheet.asp?id=39). Accessed October 19, 2003.

28. Center for Medicare and Medicaid Services (CMS). Implantable cardioverter defibrillators (ICDs) (#CAG‐ 0057N). Decision memorandum. National Coverage Analyses. Baltimore, MD: CMS; June 6, 2003. Available at: http://cms.hhs.gov/ncdr/memo.asp?id=39. Accessed October 19, 2003.

29. Center for Medicare and Medicaid Services (CMS). NCD for implantation of automatic defibrillators. Medicare Coverage Issues Manual Sec. 35‐85.CMSPublicationNo.6.Baltimore,MD:CMS;October1,2003. Availableat:http://cms.hhs.gov /mcd/viewncd.asp?ncd_id=35‐85&ncd_version=3& show=all. Accessed October 19, 2003.

30. Parkes J, Bryant J, Milne R. Implantable cardioverter defibrillators: Arrhythmias. A rapid and systematic review.

Page 36: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

36 of 44

Health Technol Assess. 2000;4(26):1‐69. 31. National Institute for Clinical Excellence (NICE). Guidance

on the use of implantable cardioverter defibrillators for arrhythmias. Technology Appraisal 11. London, UK: NICE; 2000.

32. Connolly SJ, Talajic M. Chapter 1. Summary of the CCS Consensus Conference on prevention of sudden death from cardiac arrhythmia. Can J Cardiol. 2000;16(10):1298‐1302.

33. Noorani HZ, Connolly SJ, Talajic M, et al. Implantable cardioverter defibrillator (ICD) therapy for sudden cardiac death. Can J Cardiol. 2000:16(10):1293‐1324.

34. L'Agence Nationale d'Accreditation d'Evaluation en Sante (ANAES). Implantable cardiac defibrillators (an update) [summary]. Paris, France: ANAES; January 2001.

35. Aass H, Hegrenaes L, Heldal M, et al. Implantable defibrillator. SMM‐Report 1/2002. Oslo, Norway: Norwegian Centre for Health Technology Assessment (SMM); 2002.

36. Ontario Ministry of Health and Long‐Term Care. Literature review of implantable cardioverter‐defibrillators. Health Technology Assessment Scientific Literature Review. Toronto, ON: Ontario Ministry of Health and Long‐Term Care; July 2003.

37. Swedish Council on Technology Assessment in Health Care (SBU). Implantable defibrillator ‐ early assessment briefs (Alert). Stockholm, Sweden: SBU; 2003.

38. Antezano ES, Hong M. Sudden cardiac death. J Intensive Care Med. 2003;18(6):313‐329.

39. Bansch D, Antz M, Boczor S, et al. Primary prevention of sudden cardiac death in idiopathic dilated cardiomyopathy: The Cardiomyopathy Trial (CAT). Circulation. 2002;105:1453‐1458.

40. Strickberger SA, Hummel JD, Bartlett TG, et al. Amiodarone versus implantable cardioverter‐defibrillator: Randomized trial in patients with nonischemic dilated cardiomyopathy and asymptomatic nonsustained ventricular tachycardia ‐ AMIOVIRT. J Am Coll Cardiol. 2003;41:1707‐1712.

41. Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004;350:2152‐2158.

Page 37: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

37 of 44

42. Bristow MR, Saxon LA, Boehmer J, et al. Cardiac‐ resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004;350:2140‐2150.

43. Connolly SJ, Hohnloser SJ, and the DINAMIT Steering Committee and Investigators. DINAMIT: Randomized trial of prophylactic implantable defibrillator therapy versus optimal medical treatment early after myocardial infarction: The Defibrillator in Acute Myocardial Infarction Trial. American College of Cardiology Scientific Session 2004. Bethesda, MD: American College of Cardiology; 2004. Available at: http://www.acc04online.org/ondemand /trials1/sessions.asp?link=R. Accessed November 15, 2004.

44. Center for Medicare and Medicaid Services (CMS). Decision Memo for Implantable Defibrtillators (CAG‐00157R3). Medicare Coverage Database. Baltimore, MD: CMS; January 27, 2005. Available at: http://www.cms.hhs.gov /mcd/viewdecisionmemo.asp?id=148 (http://www.cms.hhs.gov /mcd/viewdecisionmemo.asp?id=148). Accessed February 4, 2005.

45. Bardy GH, Lee KL, Mark DB, et al., and the SCD‐HeFT Investigators. Amiodarone or an implantable cardioverter‐ defibrillator for congestive heart failure. N Engl J Med. 2005;352:225‐237.

46. Goldman L, Hashimoto B, Cook EF, et al. Comparative reproducibility and validity of systems for assessing cardiovascular functional class: Advantages of a new specific activity scale. Circulation. 1981;64(6):1227‐1264.

47. BlueCross BlueShield Association (BCBSA), Technology Evaluation Center (TEC). Special report: Cost‐effectiveness of implantable cardioverter‐defibrillators in a MADIT‐II population. TEC Assessment Program. Chicago, IL: BCBSA; April 2004;19(3). Available at: http://www.bcbs.com /tec/vol19/19_03.html. Accessed February 21, 2005.

48. Lee DS, Green LD, Liu PP, et al. Effectiveness of implantable defibrillators for preventing arrhythmic events and death: A meta‐analysis. J Am Coll Cardiol. 2003;41(9):1573‐1582.

49. Lee DSY, Green LD, Liu PP, et al. Implantable defibrillators vs antiarrhythmic drugs for left ventricular dysfunction.

Page 38: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

38 of 44

Cochrane Database Systematic Rev. 2002;2:CD003613. 50. Institute for Clinical Systems Improvement (ICSI).

Implantable cardioverter‐defibrillators for the primary prevention of sudden cardiac death due to ventricular arrhythmias. Technology Assessment Report. TA #089. Bloomington, MN:ICSI;March2005.Availableat:http://www.icsi.org /knowledge/detail.asp?catID=107&itemID=2149. Accessed May 12, 2005.

51. Murray CL, Steffensen I. Automated external defibrillators for home use. Issues in Emerging Health Technologies. Issue 69. Ottawa, ON: Canadian Coordinating Office for Health Technology Assessment; June 2005. Available at: http://www.ccohta.ca/entry_e.html. Accessed June 28, 2005.

52. Bryant J, Brodin H, Loveman E, et al. The clinical and cost‐ effectiveness of implantable cardioverter defibrillators: A systematic review. Health Technol Assess. 2005;9(36):1‐150.

53. Ontario Ministry of Health and Long‐Term Care, Medical Advisory Secretariat (MAS). Implantable cardioverter defibrillator: Prophylactic Use. Health Technology Literature Review: 2005 Update of 2003 Review. Toronto, ON: MAS; September 2005.

54. BlueCross BlueShield Association (BCBSA), Technology Evaluation Center (TEC). Use of implantable cardioverter‐ defibrillators for prevention of sudden death in patients at high risk for ventricular arrhythmia. TEC Assessment Program. Chicago, IL: BCBSA; March 2005;19(19). Available at: http://www.bcbs.com/tec/vol19/19_19.html. Accessed September 19, 2005.

55. Traub D, Ganz L. Implantable cardioverter‐defibrillators for secondary prevention: Is it worth it in the elderly? Am J Geriatr Cardiol. 2006;15(2):93‐99.

56. Franz WM, Muller OJ, Katus HA. Cardiomyopathies: From genetics to the prospect of treatment. Lancet. 2001;358(9293):1627‐1637.

57. Pilichou K, Nava A, Basso C, et al. Mutations in desmoglein‐2 gene are associated with arrhythmogenic right ventricular cardiomyopathy. Circulation.

Page 39: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

39 of 44

2006;113(9):1171‐1179. 58. Makikallio TH, Huikuri HV. Association between usage of

beta‐blocking medication and benefit from implantable cardioverter therapy. Am J Cardiol. 2006;98(9):1245‐1247.

59. Buxton M, Caine N, Chase D, et al. A review of the evidence on the effects and costs of implantable cardioverter defibrillator therapy in different patient groups, and modelling of cost‐effectiveness and cost‐utility for these groups in a UK context. Health Technol Assess. 2006;10(27):1‐180.

60. Alcaraz A, Augustovski F, Pichon‐Riviere A. Implantable cardioverter defibrillators [summary]. Report ITB No. 25. Buenos Aires, Argentina: Institute for Clinical Effectiveness and Health Policy (IECS); 2006.

61. National Institute for Health and Clinical Excellence (NICE). Implantable cardioverter defibrillators for arrhythmias: Review of Technology Appraisal 11. Technology Appraisal 95. London, UK: NICE; 2006.

62. Medical Services Advisory Committee (MSAC). Implantable cardioverter defibrillators for prevention of sudden cardiac death. MSAC Reference 32. Canberra, ACT: MSAC; 2006.

63. Sharieff W, Kaulback K. Assessing automated external defibrillators in preventing deaths from sudden cardiac arrest: An economic evaluation. Int J Technol Assess Health Care. 2007;23(3):362‐367.

64. McAlister FA, Ezekowitz J, Dryden DM, et al. Cardiac resynchronization therapy and implantable cardiac defibrillators in left ventricular systolic dysfunction. Prepared by the University of Alberta Evidence‐based Practice Center for the Agency for Healthcare Research and Quality (AHRQ). AHRQ Publication No. 07‐E009. Rockville, MD: AHRQ; June 2007.

65. Van Brabandt H, Thiry N, Neyt M, et al. The implantable cardioverter defibrillator: A health technology assessment. KCE Reports 58C. Brussels, Belgium: Belgian Health Care Knolwedge Center (KCE); 2007.

66. Blom NA. Implantable cardioverter‐defibrillators in children. Pacing Clin Electrophysiol. 2008;31 Suppl 1:S32‐ S34.

67. Bardy GH, Lee KL, Mark DB, et al; HAT Investigators. Home

Page 40: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

40 of 44

use of automated external defibrillators for sudden cardiac arrest. N Engl J Med. 2008;358(17):1793‐1804.

68. Tricenturion, LLC. Automatic external defibrillators. Local Coverage Determination No. L13613. Durable Medical Equipment Program Safeguard Contractor (DME PSC). Columbia, SC: TriCenturion; revised July 1, 2007.

69. Gula LJ, Massel D, Krahn AD, et al. Is defibrillation testing still necessary? A decision analysis and Markov model. J Cardiovasc Electrophysiol. 2008;19(4):400‐405.

70. Liu QM, Bai ZL, Liu ZJ, et al. Defibrillation threshold testing: Is it necessary during implantable cardioverter‐defibrillator implantation? Med Hypotheses. 2009;72(2):147‐149.

71. Das M. Indications for ICD and cardiac resynchronization therapy for prevention of sudden cardiac death. Expert Rev Cardiovasc Ther. 2009;7(2):181‐195.

72. Exner DV. Implantable cardioverter defibrillator therapy for patients with less severe left ventricular dysfunction. Curr Opin Cardiol. 2009;24(1):61‐67.

73. Ghanbari H, Dalloul G, Hasan R, et al. Effectiveness of implantable cardioverter‐defibrillators for the primary prevention of sudden cardiac death in women with advanced heart failure: A meta‐analysis of randomized controlled trials. Arch Intern Med. 2009;169(16):1500‐1506.

74. Tsai VW, Cooper J, Garan H, et al. The efficacy of implantable cardioverter‐defibrillators in heart transplant recipients: Results from a multicenter registry. Circ Heart Fail. 2009;2(3):197‐201.

75. Santangeli P, Di Biase L, Dello Russo A, et al. Meta‐analysis: Age and effectiveness of prophylactic implantable cardioverter‐defibrillators. Ann Intern Med. 2010;153(9):592‐599.

76. Theuns DA, Smith T, Hunink MG, et al. Effectiveness of prophylactic implantation of cardioverter‐defibrillators without cardiac resynchronization therapy in patients with ischaemic or non‐ischaemic heart disease: A systematic review and meta‐analysis. Europace. 2010;12(11):1564‐1570.

77. Hauser RG. The subcutaneous implantable cardioverter‐ defibrillator: Should patients want one? J Am Coll Cardiol.

Page 41: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

41 of 44

2013;61(1):20‐22. 78. Köbe J, Reinke F, Meyer C, et al. Implantation and follow‐up

of totally subcutaneous versus conventional implantable cardioverter‐defibrillators: A multicenter case‐control study. Heart Rhythm. 2013;10(1):29‐36.

79. Olde Nordkamp LR, Dabiri Abkenari L, Boersma LV, et al. The entirely subcutaneous implantable cardioverter‐ defibrillator: Initial clinical experience in a large Dutch cohort. J Am Coll Cardiol. 2012;60(19):1933‐1939.

80. Aydin A, Hartel F, Schlüter M, et al. Shock efficacy of subcutaneous implantable cardioverter‐defibrillator for prevention of sudden cardiac death: Initial multicenter experience. Circ Arrhythm Electrophysiol. 2012;5(5):913‐919.

81. Gold MR, Theuns DA, Knight BP, et al. Head‐to‐head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: The START study. J Cardiovasc Electrophysiol. 2012;23(4):359‐366.

82. Bardy GH, Smith WM, Hood MA, et al. An entirely subcutaneous implantable cardioverter‐defibrillator. N Engl J Med. 2010;363(1):36‐44.

83. U.S. Food and Drug Administration (FDA). Subcutaneous Implantable Defibrillator (S‐ICD) System ‐ P110042. Device Approvals and Clearances. Silver Spring, MD: FDA; updated November 11, 2012.

84. U.S. Food and Drug Administration (FDA). FDA approves first subcutaneous heart defibrillator. News & Events. Silver Spring, MD: FDA; September 28, 2012.

85. Jarman JW, Todd DM. United Kingdom national experience of entirely subcutaneous implantable cardioverter‐ defibrillator technology: Important lessons to learn. Europace. 2013;15(8):1158‐1165.

86. Weiss R, Knight BP, Gold MR, et al. Safety and efficacy of a totally subcutaneous implantable‐cardioverter defibrillator. Circulation. 2013;128(9):944‐953.

87. Saxon LA. The subcutaneous implantable defibrillator: A new technology that raises an existential question for the implantable cardioverter‐defibrillator. Circulation. 2013;128(9):938‐940.

Page 42: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

42 of 44

88. Akerstrom F, Arias MA, Pachon M, et al. Subcutaneous implantable defibrillator: State‐of‐the art 2013. World J Cardiol. 2013;5(9):347‐354.

89. Pettit SJ, McLean A, Colquhoun I, et al. Clinical experience of subcutaneous and transvenous implantable cardioverter defibrillators in children and teenagers. Pacing Clin Electrophysiol. 2013;36(12):1532‐1538.

90. Majithia A, Estes NA 3rd, Weinstock J. Advances in sudden death prevention: The emerging role of a fully subcutaneous defibrillator. Am J Med. 2014;127(3):188‐194.

91. O'Gara PT, Kushner FG, Ascheim DD, et al. 2013 ACCF/AHA guideline for the management of ST‐elevation myocardial infarction: A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol. 2013;61(4):e78‐e140.

92. Epstein AE, Abraham WT, Bianco NR, et al. Wearable cardioverter‐defibrillator use in patients perceived to be at high risk early post‐myocardial infarction. J Am Coll Cardiol. 2013;62(21):2000‐2007.

93. Zei PC. Is the wearable cardioverter‐defibrillator the answer for early post‐myocardial infarction patients at risk for sudden death?: Mind the gap. J Am Coll Cardiol. 2013;62(21):2008‐2009.

94. Adler A, Halkin A, Viskin S. Wearable cardioverter‐ defibrillators. Circulation. 2013;127(7):854‐860.

95. Lambiase PD, Barr C, Theuns DAMJ, et al; on behalf of the EFFORTLESS Investigators. Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S‐ICD Registry. Eur Heart J. 2014;35(25):1657‐1665.

96. Gula LJ, Massel D, Krahn AD, et al. Is defibrillation testing still necessary? A decision analysis and Markov model. J Cardiovasc Electrophysiol. 2008;19(4):400‐405.

97. Bianchi S, Ricci RP, Biscione F, et al. Primary prevention implantation of cardioverter defibrillator without defibrillation threshold testing: 2‐year follow‐up. Pacing Clin Electrophysiol. 2009;32(5):573‐578.

98. Stefano B, Pietro RR, Maurizio G, et al. Defibrillation testing during implantable cardioverter‐defibrillator implantation

Page 43: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

43 of 44

in Italian current practice: The Assessment of Long‐term Induction clinical ValuE (ALIVE) project. Am Heart J. 2011;162(2):390‐397.

99. Russo AM, Chung MK. Is defibrillation testing necessary? Cardiol Clin. 2014;32(2):211‐224.

100. Healey JS, Hohnloser SH, Glikson M, et al; Shockless IMPLant Evaluation [SIMPLE] investigators. Cardioverter defibrillator implantation without induction of ventricular fibrillation: A single‐blind, non‐inferiority, randomised controlled trial (SIMPLE). Lancet. 2015;385(9970):785‐791.

101. Weinstock J, Selan J, Majithia A. Subcutaneous implantable cardioverter defibrillators. UpToDate Inc., Waltham, MA. Last reviewed April 2015.

102. Vehmeijer JT, Brouwer TF, Limpens J, et al. Implantable cardioverter‐defibrillators in adults with congenital heart disease: A systematic review and meta‐analysis. Eur Heart J. 2016;37(18):1439‐1448.

103. Hu ZY, Zhang J, Xu ZT, et al. Efficiencies and complications of dual chamber versus single chamber implantable cardioverter defibrillators in secondary sudden cardiac death prevention: A meta‐analysis. Heart Lung Circ. 2016;25(2):148‐154.

104. Enriquez AD, Calenda B, Miller MA, et al. The role of implantable cardioverter‐defibrillators in patients with continuous flow left ventricular assist devices. Circ Arrhythm Electrophysiol. 2013;6(4):668‐674.

105. Fauchier L, Alonso C, Anselme F, et al. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators: Groupe de Rythmologie et Stimulation Cardiaque de la Société Française de Cardiologie and Société Française de Gériatrie et Gérontologie. Arch Cardiovasc Dis. 2016;109(10):563‐585.

106. Vakil K, Kazmirczak F, Sathnur N, et al. Implantable cardioverter‐defibrillator use in patients with left ventricular assist devices: A systematic review and meta‐ analysis. JACC Heart Fail. 2016;4(10):772‐779.

107. Agrawal S, Garg L, Nanda S, et al. The role of implantable cardioverter‐defibrillators in patients with continuous flow left ventricular assist devices ‐ A meta‐analysis. Int J Cardiol. 2016;222:379‐384.

Page 44: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

44 of 44

108. Haugaa KH, Tilz R, Boveda S, et al. Implantable cardioverter defibrillator use for primary prevention in ischaemic and non‐ischaemic heart disease‐indications in the post‐DANISH trial era: Results of the European Heart Rhythm Association survey. Europace. 2017;19(4):660‐664.

Page 45: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

45 of 44

Copyright Aetna Inc. All rights reserved. Clinical Policy Bulletins are developed by Aetna to assist in administering plan benefits and constitute neither offers of coverage nor medical advice. This Clinical Policy Bulletin contains only a partial, general description of plan or program benefits and does not constitute a contract. Aetna does not provide health care services and, therefore, cannot guarantee any results or outcomes. Participating providers are independent contractors in private practice and are neither employees nor agents of Aetna or its affiliates. Treating providers are solely responsible for medical advice and treatment of members. This Clinical Policy Bulletin may be updated and therefore is subject to change.

Copyright © 2001‐2017 Aetna Inc.

Page 46: *Please see amendment for Pennsylvania Medicaid at the end … · 2017-09-20 · 1 of 44 . Number: 0585. Policy *Please see amendment for Pennsylvania Medicaid at the end of this

AETNA BETTER HEALTH® OF PENNSYLVANIA

Amendment to Aetna Clinical Policy Bulletin Number: 0585 Cardioverter‐

Defibrillators

There are no amendments for Medicaid.

www.aetnabetterhealth.com/pennsylvania revised 08/11/2017