- 1 -
ENGLISH
Thank you for choosing Delta DVP-SV. DVP-SV is a 28-point (16 input + 12 output) PLC
MPU, offering various instructions and with 16k steps program memory, able to connectto all DVP-SS/SA/SX/SC/SV series extension models, including digital I/O (max. 512points), analog modules (for A/D, D/A conversion and temperature measurement) and
all kinds of high-speed extension modules. 4 groups of high-speed (200kHz) pulse
output and 2 two-axis interpolation instructions satisfy all kinds of applications. DVP-SVis small in size and easy to install.
This instruction sheet only provides introductory information on electricalspecifications, general specifications, installation and wiring. For detalied infromationon programming and intructions, please refer to DVP-PLC Application Manual:
Programming. For information about optional peripherals, please see individualproduct instuction sheet or DVP-PLC Application Manual: Special Modules.
This is an OPEN-TYPE device and therefore should be installed in an enclosure freeof airborne dust, humidity, electric shock and vibration. The enclosure should preventnon-maintenance staff from operating the device (e.g. key or specific tools arerequired to open the enclosure) in case danger and damage on the device may
occur.
DO NOT connect input AC power supply to any of the I/O terminals; otherwiseserious damage may occur. Check all the wiring again before switching on the power.
Make sure the groud terminal is correctly grounded in order to preventelectromagnetic interference. DO NOT touch any internal when the power is switchedoff.
Product Profile
Direct fastening hole
Nameplate[ Figure 1 ]
I/O terminal
COM1(RS-232)program I/Ocommunicationport
Left-side moduleconnection port
DIN rail clip
RUN/STOP switch
I/O indicator
VR0: M1178 /D1178enabledcorresponding value
VR1: M1179 enabled/D1179corresponding value
POWER/RUN/BAT.LOW/ERROR indicator
COM1(RS-232) receivingcommunication (Rx) indicator
COM2(RS-485) sendingcommunication (Tx) indicator
2
3
4
7
8
5
6
9
11
12
13
1
10
3PIN removable terminal(standard component) I/O module
positioning hole
[ Figure 2 ]
I/O moduleconnection port
COM2(RS-485)communication port(Master/Slave)
Power input portI/O module fastening clip
Mounting slot(35mm)
Power input connectioncable (standard component)
14
15
16
17
18
19
20
21
8/10/2019 PLC DVP28SV11T
3/20
- 2 -
Electrical Specifications
Model
ItemDVP28SV11R DVP28SV11T
Power supplyvoltage
24VDC (-15% ~ 20%) (with counter-connection protection on thepolarity of DC input power)
Inrush current Max. 2.2A@24VDC
Fuse capacity 2.5A/30VDC, Polyswitch
Power consumption 6W
Insulation resistance > 5M(all I/O point-to-ground: 500VDC)
Noise immunity
ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,Analog & Communication I/O: 1kV
Damped-Oscillatory Wave: Power Line: 1kV, Digital I/O: 1kVRS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
GroundingThe diameter of grounding wire shall not be less than that of the wiringterminal of the power. (When PLCs are in use at the same time, pleasemake sure every PLC is properly grounded.)
Operation / storage
Operation: 0C ~ 55C (temperature); 50 ~ 95% (humidity);
pollution degree 2
Storage: -25C ~ 70C (temperature); 5 ~ 95% (humidity)
Agency approvalsUL508European community EMC Directive 89/336/EEC and Low VoltageDirective 73/23/EEC
Vibration / shockimmunity
International standards: IEC61131-2, IEC 68-2-6 (TESTFc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
Weight (g) 260 240
Input Point
24VDC single common port inputSpec.Items 200kHz 20kHz 10kHz
Input No. X0, X1, X4, X5 X10, X11, X14, X15X6, X7, X12, X13,
X16, X17
Input voltage (10%) 24VDC, 5mA
Input impedance 4.7k 3.3k 4.7k
OffOn > 4mA (16.5V) > 6mA (18.5V) > 4mA (16.5V)Action level
On
Off < 1.5mA (8V) < 2.2mA (8V) < 1.5mA (8V)OffOn < 150ns < 3.5s < 8sResponse
time OnOff < 3s < 20s < 60s
Filter time Adjustable within 10 ~ 60ms by D1020, D1021 (Default: 10ms)
Output Point
TransistorSpec.Items
Relay
High-speed Low-speed
Output No. Y0 ~ Y7, Y10 ~ Y13 Y0 ~ Y4, Y6Y5, Y7, Y10
~ Y13Y14 ~ Y17,
Y20 ~ #1
Max. frequency 1Hz 200kHz 10kHz 1kHz
Working voltage 250VAC, < 30VDC 30VDC
Max. load Resistive 1.5A/1 point (5A/COM)0.3A/1 point @ 40C; When the output ofY0, Y1, Y10 and Y11 is high-speed pulse,
Y0,Y1, Y10 and Y11 = 30mA
8/10/2019 PLC DVP28SV11T
4/20
- 3 -
Output Point
TransistorSpec.Items
RelayHigh-speed Low-speed
Inductive #2 9W (30VDC)Max. load
Lamp 20WDC/100WAC 1.5W (30VDC)
OffOn 0.2s 20s
8/10/2019 PLC DVP28SV11T
5/20
- 4 -
wires being loose. The retaining clip is at the bottom of the PLC. To secure the PLC toDIN rail, pull down the clip, place it onto the rail and gently push it up. To remove thePLC, pull the retaining clip down with a flat screwdriver and gently remove the PLC from
DIN rail. See [Figure 6].
Wiring1. Use 22-16AWG (1.5mm) single or multiple core wire on
I/O wiring terminals. See the figure in the right hand sidefor its specification. PLC terminal screws should betightened to 1.90 kg-cm (1.65 in-lbs) and please use only60/75C copper conductor.
22-16AWG
< 1.5mm
2. DO NOT wire empty terminal. DO NOT place the I/O signal cable in the same wiringcircuit.
3. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring. Tear
off the sticker on the heat dissipation hole for preventing alien substances fromdropping in, to ensure normal heat dissipation of the PLC.
Power Supply
The power input of DVP-SV is DC. When operating DVP-SV, note the following points:
1. The power is connected to two terminals, 24VDC and 0V, and the range of power is20.4 ~ 28.8VDC. If the power voltage is less than 20.4VDC, the PLC will stop running,all outputs go Off, and the ERROR indicator will start to blink continuously.
2. The power shutdown for less than 10ms will not affect the operation of the PLC.However, the shutdown time that is too long or the drop of power voltage will stop theoperation of the PLC, and all outputs will go off. When the power returns to normalstatus, the PLC will automatically resume the operation. (Please take care of thelatched auxiliary relays and registers inside the PLC when doing the programming).
Safety Wiring
Since DVP-SV is only compatible with DC power supply, Deltas power supply modules
(DVPPS01/DVPPS02) are the suitable power supplies for DVP-SV. We suggest youinstall the protection circuit at the power supply terminal to protect DVPPS01 orDVPPS02. See the figure below.
1 AC power supply:100 ~ 240VAC, 50/60Hz 2 Breaker3 Emergency stop: This button cuts off the system power supply when accidental
emergency takes place.
4 Power indicator 5 AC power supply load6 Power supply circuit protection fuse (2A) 7 DVPPS01/DVPPS028 DC power supply output: 24VDC, 500mA 9 DVP-PLC (main processing unit)10 Digital I/O module
8/10/2019 PLC DVP28SV11T
6/20
- 5 -
Input Point Wiring
There are 2 types of DC inputs, SINK and SOURCE. (See the example below. Fordetailed point configuration, please refer to the specification of each model.)
DC Signal IN SINK mode
Input point loop equivalent circuit
+24V
24G
S/S
X0
24VDC
X1[ Figure 8 ]
DC Signal IN SOURCE mode
Input point loop equivalent circuit
+24V
24G
S/S
X0
24VDC
X1[ Figure 9 ]
Output Point Wiring
1. DVP-SV has two output modules, relay and transistor. Be aware of the connection ofshared terminals when wiring output terminals.
2. Output terminals, Y0, Y1, and Y2, of relay models use C0 common port; Y3, Y4, andY5 use C1 common port; Y6, Y7, and Y10 use C2 common port; Y11, Y12, and Y13
use C3 common port. See [Figure 10].
When the output points are enabled, their corresponding indicators on the frontpanel will be on.
3. Output terminals, Y0 and Y1, of transistor models use C0 common port; Y2 and Y3
use C1 common port; Y4 and Y5 use C2 common port; Y6 and Y7 use C3 commonport; Y10, Y11, Y12 and Y13 use C4 common port. See [Figure 11].
4. Isolation circuit: The optical coupler is used to isolate signals between the circuitinside PLC and input modules.
Relay (R) output circuit wiring
8/10/2019 PLC DVP28SV11T
7/20
- 6 -
1 DC power supply 2 Emergency stop: Uses external switch3 Fuse: Uses 5~10A fuse at the shared terminal of output contacts to protect the output circuit4 Transient voltage suppressor (SB360 3A 60V): Extends the life span of contact.
1. Diode suppression of DC load: Used when in smaller power [Figure 13]
2. Diode + Zener suppression of DC load: Used when in larger power and frequent On/Off[Figure 14]
5 Incandescent light (resistive load) 6 AC power supply7 Manually exclusive output: For example, Y3 and Y4 control the forward running and reverse
running of the motor, forming an interlock for the external circuit, together with the PLCinternal program, to ensure safe protection in case of any unexpected errors.
8 Neon indicator 9 Absorber: Reduces the interference on AC load [Figure 15]
Transistor (T) output circuit wiring
8/10/2019 PLC DVP28SV11T
8/20
- 7 -
1 DC power supply 2 Emergency stop 3 Circuit protection fuse4 The output of the transistor model is open collector. If Y0/Y1 is set to pulse output, the
output current has to be bigger than 0.1A to ensure normal operation of the model.
1. Diode suppression: Used when in smaller power [Figure 18]
2. Diode + Zener suppression: Used when in larger power and frequent On/Off [Figure 19]
5
Manually exclusive output: For example, Y10 and Y11 control the forward running andreverse running of the motor, forming an interlock for the external circuit, together with thePLC internal program, to ensure safe protection in case of any unexpected errors.
BAT.LOW indicatorBAT.LOW indicator will be on when the battery is in low voltage. When this happens,
change the battery as soon as possible in case your program and data saved in thelatched area will be lost.
After the DC24V power is switched off, the data in the latched area will be stored inSRAM memory and its power supplied by the rechargeable battery. Therefore, when thebattery is damaged or cannot be changed, the data in the program and latched area willbe lost. If you need to permanently save the data in the latched area in the program and
device D, please refer to Flash ROM permanently saved and recover mechanism asstated below.
Permanently saved mechanism:
You can use WPLSoft (Options -> PLCFlash) to indicate whether to permanently
store the data in the latched area in Flash ROM memory (the new indicated data willreplace all data previously saved in the memory).
Recover mechanism:
If the rechargeable battery is in low voltage, resulting in possible loss of data in theprogram, the PLC will automatically restore the data in the latched area in the program
and device D of Flash ROM into SRAM memory (M1176 = On) next time when DC24V isre-powered. The ERROR LED flashing will remind you that if the recorded program isable to resume its execution. You only need to shut down and re-power the PLC once to
restart its operation (RUN).
1. The rechargeable lithium-ion battery in DVP-SV is mainly used on the latchedprocedure and data storage.
2. The lithium-ion battery has been fully charged in the factory and is able to retain thelatched procedure and data storage for 12 months. If DVP-SV has not been poweredand used for more than 12 months, the battery will be out of power upon normal
consumption, and the procedure and data will be lost.
3. The lithium-ion battery has longer life span than ordinary battery; therefore there isno need to change battery very frequently. You can charge the battery any time
without having to worry its chargeability will decrease. You can also recharge thebattery even when there is still power in the battery.
4. Please be aware of the date of manufacturing. The charged battery can sustain for
12 months from its date of manufacture. If you find that the BAT.LOW indicator stayson after PLC is powered, it means the battery voltage is low and the battery is beingcharged. DVP-SV has to remain on for more than 24 hours to fully charge the battery.
If the indicator turns from on to flash (every 1 second), it means that the batterycannot be charged anymore. Please correctly process your data in time and sendthe PLC back to Delta for changing a new battery.
Accuracy (month/second) of RTC
Temperature (C/F) 0 / 32 25 / 77 55 / 131
Max. inaccuracy (second) -117 52 -132
8/10/2019 PLC DVP28SV11T
9/20
- 8 -
DVP DVP-SV 28 16 + 12 PLC 16k steps SS/SA/SX/SC/SV I/O 512 A/DD/A I/O 200kHz
DVP-PLC DVP-PLC
OPEN TYPE/
1 [Figure 1] [Figure 2]
1 I/O 12 COM1RS-2322 13 DIN 3 COM1RS-232Rx 14 COM2RS-485Master/Slave
4
COM2
RS-485
Tx
15
5 16 3PIN 6 RUNSTOP 17 7 VR0M1178 D1178 18 I/O 8 VR1M1179 D1179 19 I/O 9 20 DIN (35mm)10 21 I/O
11
DVP28SV11R DVP28SV11T
24VDC (-15% ~ 20%) Max. 2.2A@24VDC
2.5A/30VDC
(Polyswitch)
6W > 5M 500VDC
ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,Analog & Communication I/O: 1kV
Damped-Oscillatory Wave: Power Line: 1kV, Digital I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
PLC
0C ~ 55C50 ~ 95% 2-25C ~ 70C5 ~ 95%
UL508
European community EMC Directive 89/336/EEC and Low VoltageDirective 73/23/EEC
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC68-2-27 (TEST Ea)
8/10/2019 PLC DVP28SV11T
10/20
- 9 -
DVP28SV11R DVP28SV11T
260g 240g
24VDC
200kHz 20kHz 10kHz
No. X0, X1, X4, X5 X10, X11, X14, X15 X6, X7, X12, X13,X16, X17
10% 24VDC, 5mA 4.7k 3.3 k 4.7 k
OffOn > 4mA (16.5V) > 6mA (18.5V) > 4mA (16.5V)
OnOff < 1.5mA (8V) < 2.2mA (8V) < 1.5mA (8V)
OffOn < 150ns < 3.5s < 8s OnOff < 3s < 20s < 60s D1020 D1021 10 ~ 60 ms (10ms)
No. Y0 ~ Y7, Y10 ~ Y13 Y0 ~ Y4, Y6Y5, Y7, Y10
~ Y13
Y14 ~ Y17,
Y20 ~ #1
1Hz 200kHz 10kHz 1kHz 250VAC, < 30VDC 30VDC
1.5A/1 point (5A/COM) 0.3A/1 @ 40C Y0, Y1, Y10, Y11 Y0,Y1, Y10, Y11 = 30mA #2 9W (30VDC)
20WDC/100WAC 1.5W (30VDC)
OffOn 0.2s 20s
8/10/2019 PLC DVP28SV11T
11/20
- 10 -
1. / 22-16AWG (1.5mm) 4 PLC 1.90 kg-cm (1.65 in-lbs) 60/75C
2. 3.
PLC
PLC
DVP-SV 1. 24VDC 0V 20.4 ~ 28.8VDC
20.4VDC PLC OffERROR LED 2. 10ms PLC
PLC OffPLC PLC
DVP-SV DC Only (DVPPS01/DVPPS02) DVP-SVDVPPS01/DVPPS02 4 [Figure 7]
1
100 ~ 240VAC, 50/60Hz
2
3 4 5 6 2A 7 DVPPS01/DVPPS02 8 24VDC500mA 9 DVP PLC 10 /
DC SINK SOURCE 5 [Figure 8][Figure 9]
1. DVP-SV PLC
2. Y0Y1Y2 C0 Y3Y4Y5 C1 Y6Y7
Y10 C2 Y11Y12Y13 C3 5 [Figure10]
3. Y0Y1 C0 Y2Y3 C1 Y4Y5 C2Y6Y7 C3 Y10Y11Y12Y13 C4 6 [Figure 11]
4. PLC
5 [Figure 12]
1 2 3 5 ~ 10A 4
1. DC 6 [Figure 13]2. DC +Zener On/Off
6 [Figure 14]5 6
8/10/2019 PLC DVP28SV11T
12/20
- 11 -
7 Y3 Y4 PLC
8 9 6 [Figure 15]
Y0
LED
C0
< 0.3A
6 [Figure 17]
1 2 3 4 (Open Collector) Y0/Y1
0.1A1. 6 [Figure 18]2. +Zener On/Off 6 [Figure 19]
5 Y10 Y11 PLC
BAT.LOW BAT.LOW 24V SRAM SRAM D Flash ROM
WPLSoft
-->
PLCFlash D FlashROM Flash ROM
PLC Flash ROM D SRAM PLC (RUN)
1. DVP-28SV
2. 12 DVP-28SV 12
3.
4. 12 BAT.LOW DVP-28SV 24
1 PLC
(C/F) 0/32 25/77 55/131 -117 52 -132
8/10/2019 PLC DVP28SV11T
13/20
- 12 -
DVP DVP-SV 28 16 + 12 PLC 16k steps SS/SA/SX/SC/SV I/O 512 A/DD/A I/O 200kHz
DVP-PLC DVP-PLC
(OPEN TYPE)
1 [Figure 1] [Figure 2]
1 I/O 12 COM1RS-2322 13 DIN 3 COM1RS-232Rx 14 COM2RS-485Master/Slave
4
COM2
RS-485)
Tx
15
5 16 3PIN 6 RUNSTOP 17 7 VR0M1178 D1178 18 I/O 8 VR1M1179 D1179 19 I/O 9 20 DIN 35mm10 21 I/O
11
DVP28SV11R DVP28SV11T
24VDC (-15% ~ 20%)
Max. 2.2A@24VDC
2.5A/30VDC (Polyswitch)
6W
> 5M 500VDC
ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,Analog & Communication I/O: 1kV
Damped-Oscillatory Wave: Power Line: 1kV, Digital I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
PLC
0C ~ 55C50 ~ 95% 2
-25C ~ 70C5 ~ 95%
UL508
European community EMC Directive 89/336/EEC and Low VoltageDirective 73/23/EEC
IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC68-2-27 (TEST Ea)
8/10/2019 PLC DVP28SV11T
14/20
- 13 -
DVP28SV11R DVP28SV11T
260g 240g
24VDC
200kHz 20kHz 10kHz
No. X0, X1, X4, X5 X10, X11, X14, X15X6, X7, X12, X13,
X16, X17
10% 24VDC, 5mA
4.7k 3.3k 4.7k
OffOn > 4mA (16.5V) > 6mA (18.5V) > 4mA (16.5V)
OnOff < 1.5mA (8V) < 2.2mA (8V) < 1.5mA (8V)
Off
On < 150ns < 3.5s < 8s OnOff < 3s < 20s < 60s
D1020 D1021 10 ~ 60 ms (10ms)
No. Y0 ~ Y7, Y10 ~ Y13 Y0 ~ Y4, Y6
Y5, Y7, Y10
~ Y13
Y14 ~ Y17,
Y20 ~ #1
1Hz 200kHz 10kHz 1kHz
250VAC, < 30VDC 30VDC
1.5A/1 point (5A/COM)0.3A/1 @ 40C Y0, Y1, Y10, Y11
Y0,Y1, Y10, Y11 = 30mA
#2
9W (30VDC)
20WDC/100WAC 1.5W (30VDC)
OffOn 0.2s 20s
8/10/2019 PLC DVP28SV11T
15/20
- 14 -
1. / 22-16AWG (1.5mm) 4 PLC 1.90 kg-cm (1.65 in-lbs) 60/75C
2.
3. PLC PLC
DVP-SV
1. 24VDC 0V 20.4VDC ~ 28.8VDC20.4VDC PLC OffERROR LED
2. 10ms PLC
PLC
Off
PLC
PLC
DVP-SV DC Only
(DVPPS01/DVPPS02) DVP-SV DVPPS01/DVPPS02
4 [Figure 7]
1 100 ~ 240VAC, 50/60Hz
2
3 4 5 6 2A 7 DVPPS01/DVPPS02 8 24VDC500mA 9 DVP PLC 10 /
DC DC
5 [Figure 8][Figure 9]
1. DVP-SV PLC
2. Y0Y1Y2 C0 Y3Y4Y5 C1 Y6Y7
Y10 C2 Y11Y12Y13 C3 5 [Figure10]
3. Y0Y1 C0 Y2Y3 C1 Y4Y5 C2
Y6Y7 C3 Y10Y11Y12Y13 C4
6 [Figure 11]
4. PLC
5 [Figure 12]
1 2 3 5 ~ 10A 4
1. DC 6 [Figure 13]
2. DC +Zener On/Off 6
[Figure 14]
8/10/2019 PLC DVP28SV11T
16/20
- 15 -
5 6 7 Y3 Y4
PLC
8 9 6 [Figure 15]
Y0
LED
C0
< 0.3A
6 [Figure17]
1 2 3 4 (Open Collector) Y0/Y1
0.1A
1. 7 [Figure 18]
2. +Zener On/Off 7 [Figure 19]
5 Y10 Y11 PLC
BAT.LOW BAT.LOW 24V SRAM
SRAM D
Flash ROM WPLSoft -->
PLCFlash D FlashROM Flash ROM
1
PLC Flash ROM D SRAM PLC (RUN)
1. DVP-28SV
2. 12 DVP-28SV 12
3.
4.
12
BAT.LOW
DVP-28SV 24 1 PLC
(C/F) 0/32 25/77 55/131
-117 52 -132
8/10/2019 PLC DVP28SV11T
17/20
- 16 -
....... TRKE .........
Delta DVP-SV serisi rnleri setiiniz iin teekkrler. DVP-SV serisi PLClerin CPUda 16-giri
+ 12-kolmak zere toplam 28-nokta ve 16K program kapasitesi vardr. Farkluygulamalar
gerekletirmek iin eitli komutlar sunar. Dijital giri/k(maksimum 512 ilave giri/k), ve
analog (A/D, D/A evrim ve scaklk) gibi SS/SA/SX/SC/SV CPUlara balanabilen tm modlleri
desteklemesinin yansra her eit yeni yksek-hzlilave modlleri destekler. 4-grup
yksek-hzl(200kHz) pulse kve 2-eksen interpolasyon komutlarile tm uygulamalarauygun zmler sunar. DVP-SV serisi kk boyutlu olup kurulumu ok kolaydr.
Bu bilgi dkmansadece rnn elektriksel zellikleri, genel zellikleri, kurulumu ve
balantsile ilgili aklamalar salar. Komutlar ve programlama ile ilgili detaylbilgi sahibi
olmak iin ltfen DVP-PLC Application Manual: Programming e baknz. Opsiyonel evre
donanmlarhakknda daha fazla bilgi sahibi olmak iin, ilgili donanma ait bilgi dkmanna
bakabilir veya DVP-PLC Application Manual: Special Modules inceleyebilirsiniz.
DVP-SV AIK TP bir rndr. PLC toz, rutubet, elektrik oku ve titreimden uzak yerlerede
muhafaza edilmelidir. Ayrca kiisel ve/veya maddi zararlarnlemek iin rne yetkili
olmayan kiilerin mdahale etmesini engeleleyecek koruyucu nlemler alnmaldr. (rnn
kurulduu panoya kilit konulmasvb).
rnn giri/kterminallerine kesinlikle AC power balamaynz, aksi halde rn zarar
grebilir. rne enerji vermeden nce tm balantlarn doru olduunu kontrol ediniz.
Elektromanyetik grlty nlemek iin PLCnin dzgn topraklandna emin olunuz .
Enerji varken rn terminallerine dokunmaynz.
rn Grn
Ltfen ngilizce (English) blmde ekil 1[Figure 1] ve ekil 2 [Figure 2]ye baknz.
Elektriksel zelliklerModel
MaddeDVP28SV11R DVP28SV11T
Power supply voltaj 24VDC (-15% ~ 20%) (DC power giriters balant(polarite) korumas
SzntAkm Max. 2.2A@24VDC
Sigorta Kapasitesi 2.5A/30VDC, Polyswitch
G Tketimi 6WIzolasyon direnci > 5M(Tm I/O nokta-ground: 500VDC)
Ses Bakl
ESD (IEC 61131-2, IEC 61000-4-2): 8kV Hava DearjEFT (IEC 61131-2, IEC 61000-4-4): G Hatt: 2kV, Dijital I/O: 1kV, Analog &Haberleme I/O: 1kVSnml-SalnmlDalga: G Hatt: 1kV, Dijital I/O: 1kVRS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
TopraklamaTopraklama kablosunun kesiti power terminal kablosunun kesitinden kkolmamaldr. (Birok PLC aynanda kullanlacazaman, ltfen her birPLCnin dzgn topraklandndan emin olunuz.)
alma / Saklama alma: 0C ~ 55C (scaklk); 50 ~ 95% (rutubet); kirlenme derece 2
Saklama: -25C ~ 70C (scaklk); 5 ~ 95% (rutubet)
Acente OnaylarUL508Avrupa Topluluu EMC Directive 89/336/EEC ve Low Voltage Directive73/23/EEC
Titreim / ok direnciUluslararasstandartlar: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 &IEC 68-2-27 (TEST Ea)
Arlk (g) 260 240
Giriler24VDC tek ortak port giriizellik
Madde 200kHz 20kHz 10kHz
GiriNo. X0, X1, X4, X5 X10, X11, X14, X15X6, X7, X12, X13, X16,
X17
Girivoltaj(10%) 24VDC, 5mA
Giriempedans 4.7k 3.3k 4.7k
OffOn > 4mA (16.5V) > 6mA (18.5V) > 4mA (16.5V)Aktif seviye
OnOff < 1.5mA (8V) < 2.2mA (8V) < 1.5mA (8V)
8/10/2019 PLC DVP28SV11T
18/20
- 17 -
Giriler
24VDC tek ortak port giriizellikMadde 200kHz 20kHz 10kHz
OffOn < 150ns < 3.5s < 8sCevapZaman OnOff < 3s < 20s < 60s
Filtre zaman D1020, D1021den 10 ~ 60ms arasayarlanabilir (Default: 10ms)
klar
TransistrzellikMadde
RleYksek-hz Dk-hz
kNo. Y0 ~ Y7, Y10 ~ Y13 Y0 ~ Y4, Y6Y5, Y7, Y10 ~
Y13Y14 ~ Y17,
Y20 ~ #1
Maksimum frekans 1Hz 200kHz 10kHz 1kHz
alma Voltaj 250VAC, < 30VDC 30VDC
Resistif 1.5A/1 nokta (5A/COM) 0.3A/1 nokta @ 40Cde; Y0, Y1, Y10 ve Y11
klaryksek-hzlpulse kolarakkullanldnda, Y0,Y1, Y10 ve Y11 = 30mA
Endktif #2 9W (30VDC)
Maksimumyk
Lamba 20WDC/100WAC 1.5W (30VDC)
OffOn 0.2s 20s
8/10/2019 PLC DVP28SV11T
19/20
- 18 -
DVP-SV serisi rnlerin enerji besleme girii DCdir. DVP-SV serisi rnler kullanlacazamanaadaki noktalara dikkat ediniz:
1. G kaynaPLCnin 24VDC ve 0V terminallerine balanr. Besleme aral20.4 ~ 28.8V
DCdir. Eer besleme voltaj20.4VDCden az ise, PLC almasndurdurur, tm klar
Off olur ve ERROR indikatr srekli flash yapar.
2. 10 msden daha ksa sreli enerji kesintisi durumunda PLCnin almasetkilenmez. Eer
enerji kesintisi veya voltaj dme sresi daha uzun ise PLCnin almasdurur ve tmklar OFF olur. PLC belemesi normal seviyeye geldiinde PLC otomatik olarak
almasna geri dner. (PLC program yazlacazaman kalcyardmcrle ve registerlerin
kullanmna dikkat ediniz).
Gvenli Balant
DVP-SV serisi PLC rnleri DC beslemeli olup, Deltann g kaynarnleri olan
(DVPPS01/DVPPS02), DVP-SV PLClerin beslemesi iin ok elverilidir. DVPPS01 veya
DVPPS02 rnlerini korumak iin kullanclarn koruyucu devre kullanmasnerilir. ngilizce
(English) blmde ekil 7 [Figure 7]ye baknz.
1 AC g kayna:100 ~ 240VAC, 50/60Hz 2 Devre Kesici
3 Acil Stop: Acil bir durum meydana geldiinde bu buton sistemin beslemesini keser.
4 Power indikatr 5 AC g kaynayk
6 G kaynadevre koruma sigortas(2A) 7 DVPPS01/DVPPS02
8 DC g kaynak: 24VDC, 500mA 9 DVP-PLC (Ana ilemci nitesi)
Digital I/O modl
GiriBalants
2 eit DC giribalantsvardr, SINK ve SOURCE. (Aadaki rnee baknz. Detayl
konfigrasyon iin, her bir modelin zelliklerini inceleyiniz.)
DC Sinyal IN SINK mod
Giribalantedeer devresi (ngilizce (English) blmde ekil 8 [Figure 8]e baknz.)
DC Sinyal IN SOURCE mod
Giribalantedeer devresi (ngilizce (English) blmde ekil 9 [Figure 9]e baknz.)
kBalants
1. DVP-SV serisi rnlerde rle ve transistor olmak zere 2 tip kmodl vardr. kbalantlarnyaparken ortak terminallerin kullanmna dikkat ediniz.
2. Rle ktip PLClerde ngilizce (English) blmde ekil 10 [Figure 10]da grld gibi Y0,Y1 ve Y2 kterminalleri C0 ortak terminalini; Y3, Y4 ve Y5 C1 ortak terminalini; Y6, Y7 veY10 C2 ortak terminalini; Y11, Y12 ve Y13 ise C3 ortak terminalini kullan r.
3. klar aktif olduu zaman, n panelde bu klara karlk gelen indikatrler ON olur.
4. Transistor ktip PLClerde ngilizce (English) blmde ekil 11 [Figure 11]de grldgibi Y0, ve Y1 C0 ortak terminalini; Y2, ve Y3 C1 ortak terminalini; Y4 ve Y5 C2 ortakterminalini; Y6 ve Y7 C3 ortak terminalini; Y10, Y11, Y12 ve Y13 ise C4 ortak terminalinikullanr.
5. Izolasyon devresi: PLC ve girimodlleri devreleri arasnda sinyal izolasyonu iin optokuplrkullanlr.
Rle (R) kdevre balants(ngilizce (English) blmde ekil 12 [Figure 12]ye baknz.)
1 DC g kayna 2 Acil stop: Harici anahtar kullanr
3 Sigorta: kdevrelerini korumak iin kkontaklarnn ortak terminallerinde 5~10A sigortakullanlr
4Ani voltaj bastrma (SB360 3A 60V): Kontak mrn uzatr.1. DC yk diyot bastrma: Kk glerde kullanlr (ngilizce (English) blmde ekil13 [Figure 13]e
baknz.)
2. DC yk Diyot + Zener bastrma: Byk g ve sk On/Off durumunda kullanlr. (ngilizce (English)blmde ekil13 [Figure 13]e baknz.)
5Akkor lamba (rezistif yk) 6 AC g kayna7 Manual tek k: rnein, Y3 ve Y4 klarmotorun ileri ve geri hareketini kontrol etsin,
beklenmeyen bir hatann olumasndaha gl nlemek iin PLCnin dahili programndan bakaklar harici olarak birbirlerin nne balanabilir.
8/10/2019 PLC DVP28SV11T
20/20
8 Neon indikatr9 Dalga Emici: AC yk zerindeki grlty drmek iin ( ngilizce (English) blmde ekil15 [Figure
15]e baknz.)
Transistr (T) kdevre balants(ngilizce (English) blmde ekil16 [Figure 16] ve ekil17 [Figure 17]ye baknz.)
1 DC g kayna
2
Acil stop3
Devre koruma sigortas
4 Transistr modelinin kopen collector dr. Eer Y0/Y1 pulse kayarlanmsa, normal
almaysalamak iin, kakm0.1Aden byk olmaldr.
1. Diyot bastrma: Kk glerde kullanlr (ngilizce (English) blmde ekil 18 [Figure 18]ebaknz.)
2. Diyot + Zener bastrma: Byk g ve sk On/Off durumlarnda kullanlr. (ngilizce (English)blmde ekil 19 [Figure 19]a baknz.)
5 Manual tek k: rnein, Y10 ve Y11 klarmotorun ileri ve geri hareketini kontrol etsin,beklenmeyen bir hatann olumasndaha gl nlemek iin PLCnin dahili programndan bakaklar harici olarak birbirlerin nne balanabilir.
BAT.LOWindikatrBAT.LOW indikatr pilin voltajdt zaman ON olur. Bu durum olutuu zaman, PLC
iindeki program ve kalcdatalarn silinmemesi iin en ksa srede pili deitiriniz.
DC24V power kesildikten sonra, kalcdatalarn iindeki deerler pil tarafndan beslenen SRAM
hafzada tutulur. Bundan dolaypil deitirilemez veya zarar grrse kalcalandaki datalar ve
program kaybolur. Eer kullancnn program iinde kalcalandaki D datalarsrekli kaydetmesi
gerekiyorsa aada yazlanlar uygulanmaldr.
Srekli Kaydetme MekanizmasKalcalandaki datalarFlash ROM memorye srekli kaydetmek iin WPLSoft Program
(Options -> PLCFlash) kullanlr. (Yeni tanmlanmtm datalar hafzaya nceden
kaydedilen datalarla yer deitirir).
Geri arma Mekanizmas
Eer yeniden arj edilebilir pil voltajderse, programda oluan data kaybsonucunda, PLC,
DC24V ile yeniden enerjilendirildiinde programdaki kalcalanlardaki verileri ve Flash ROM
ierisindeki D registerlarnSRAM hafzasna (M1176=On) otomatik olarak geri ykleyecektir.
ERROR LED'in flash yapmaskullancya programn almasna (RUN) devam etmesi
isteniyorsa, bir kez PLC beslemesini kapatp yeniden enerji verilmesi gerektiini bildirir.
1. DVP-28SVnin iindeki yeniden arj edilebilir lityum-ion pil kalcilem ve datalarsaklama
amacyla kullanlr.
2. Lityum-ion pil retimden kmadan nce kalcilem ve datalar12 ay boyunca
saklayabilecek ekilde tamamen arj edilir. Eer DVP-28SV nitesi 12 ay boyunca
kullanlmaz ve/veya enerjilenmez ise saklanan ilem ve datalar kaybolur.
3. Lityum-ion pil mr dier sradan pillere gre daha uzun olduu niin srekli arj edilmeye
ihtiya duymaz. Pil arj edilebilme zellii azalmasveya bozulmasendiesine kaplmadan
herhangi bir zamanda arj edilebilir. Pilin iinde enerji varken dahi yeniden arj edebilmek
mmkndr.
4. Ltfen PLCnin retim tarihine dikkat ediniz; arj edilen pil bu tarihten itibaren 12 ay boyunca
dayanabilir. PLC enerjilendikten sonra BAT.LOW indikatrn ON olduu fark edilirse, pil
voltajdmve pilin arj edildii anlamna gelir. Bu durumda pilin tamamen arj olmasiin
DVP-28SV PLC 24 saat boyunca enerjili kalmaldr. Bu durumda indikatr ONdan 1 saniyelik
flash konuma geerse bu pilin artk arj edilemeyeceinin gstergesidir. Bu durumda
program ve datalarn yedeini dzgn bir ekilde aldktan sonra pil deiimi iin rn teknik
servisimize gnderiniz.
RTC Doruluu(ay/saniye)Scaklk (C/F) 0 / 32 25 / 77 55 / 131
Maksimum sapma (saniye) -117 52 -132