Technical Document
Revision 1.0
March, 2009
www.cermate.com
PLC Connection Guide
TN512D Communication settings between
Siemens S7-200 PPI and PanelMaster HMI
◎Revision Record
Revision Date Content Owner
TND512-E0
Page 2 of 9 www.cermate.com
Preface
This tech note introduces how to connect Siemens S7-200 PPI Port with PanelMaster
HMI.
<S7-200 CPU>
(1) PLC Parameter setting:
Execute the “STEP 7 MicroWIN” software to link with the S7-200 PLC via PPI Adapter program cable.
PPI Port (Port0 & Port1)
TND512-E0
Page 3 of 9 www.cermate.com
Create a new project and select the CPU to set its communication format from “System Block”.
NOTE: The standard format is 9600, 8, Even, 1 and the PLC Address is “2”
Execute “Set PG/PC Interafce” --- “PC/PPI cable(PPI)” option to select the correct communication port
on PC side.
TND512-E0
Page 4 of 9 www.cermate.com
Execute “Communication” option, it can find out the PLC automatically.
TND512-E0
Page 5 of 9 www.cermate.com
If the communication port is correct, you can execute the download/upload function to change the “PLC
Address”/”Baud Rate”…etc.
Connection Cable diagram
HMI Side PLC Cable Side
COM1 9-PIN Male PPI Port 9-PIN Male (RS485)
485 + 1 3 485+
485 - 6 8 485-
SG 5 5 SG
HMI Side PLC Cable Side
COM2 T.B. 5-PIN PPI Port 9-PIN Male (RS485)
485 TX+ 1 3 485+
485 TX- 4 8 485-
SG 5 5 SG
TND512-E0
Page 6 of 9 www.cermate.com
(1)HMI setting:
(a) S7-200 (PPI; 1-to-1) Setting: (Without Token Command)
Select【Device/Server:Siemens AG → Simatic S7-200 (PPI; 1-to-1)】
NOTE: Driver Name --- C39001.dll / C39001.mod
Set the HMI link port parameter identical with PLC communication parameter
TND512-E0
Page 7 of 9 www.cermate.com
(b) S7-200 (PPI; Network) Setting: (With Token Command)
Select 【Device/Server: Siemens AG → Simatic S7-200 (PPI; Network)】
NOTE: Driver Name --- C39011.dll / C39011.mod
Set the HMI link port parameter identical with PLC communication parameter
Note: The network driver is using token command to link with PLC and HMI, it can be used
to link with different devices that support PPI Network protocol.
TND512-E0
Page 8 of 9 www.cermate.com
(3) PLC Memory Address
Bit Devices (PPI; 1-to-1 & Network)
Word Devices (PPI; 1-to-1 & Network)
NOTE: Device named DBWn specified same as VWn.
~Thank You~
TND512-E0
Page 9 of 9 www.cermate.com
Technical Support Information
中國大陸 QQ專線 : 800014850 www.panelmaster.com.cn / www.cermate.com
資料下載專區 ftp:://mail.cermate.com + User name + Password (欲加入會員需要申請)
合作貼牌聯絡專線: China: 0910011916 / 86-13823788405 [email protected] Taiwan: 886-910011915 [email protected]
Worldwide: 886-910011914 [email protected]
Cermate Technologies (Shanghai) Inc. 屏通科技(上海)有限公司
Phone: +86-21-51758590~2 FAX : +86-21-51758589
E-mail: [email protected]
Shenzhen Cermate Technologies Inc. 屏通科技(深圳)有限公司
Phone: +86-755-83562179, FAX : +86-755-83562294
E-mail: [email protected]
Cermate Technologies Inc. (台湾) 屏通科技股份有限公司 7F-1, No. 168, Lien-Cheng Road, Chung-Ho City, Taipei, Taiwan 235 R.O.C.
Phone: 886-2-22437000 FAX : 886-2-22499933
E-mail: [email protected]