Planning cover letter:
2 Hogarth Road, Sulphur Creek
Applicant: eclo designs
Prepared by: Chloe Overton
Date: 04/03/20
Project no: 19023
Certificate of title: 148311/2
PID: 2745882
Site area:702m2
Municipality: Central Coast
Zone: General Residential
Proposal: Second storey Extension
Use Class: Residential
10.4.2 Setbacks and building envelope for all dwellings
Objective:
To control the siting and scale of dwellings to:
(a) provide reasonably consistent separation between dwellings on adjacent sites and a dwelling and its frontage; and
(b) Assist in the attenuation of traffic noise or any other detrimental impacts from roads with high traffic volumes; and
(c) Provide consistency in the apparent scale, bulk, massing and proportion of dwellings; and
(d) Provide separation between dwellings on adjacent sites to provide reasonable opportunity for daylight and sunlight to enter habitable rooms and private open space.
P1/P2:
The proposed building fits within the plan building setbacks; however a portion of the southern wall of the proposed second storey extends past the projected building envelope by approximately 1041-1067. And a portion of the approximately 1582 of the north/west corner of the deck/balcony roof section also extends past the projected building envelope for the acceptable solutions.
Being a corner block the front set back isn’t consistent with the existing neighbouring properties. And the other properties on the street have dramatically different setbacks for instance the dwelling of 4 Hogarth road has a front setback of approximately 5m and the dwelling of 362 preservation drive has an approximate front set back of only 2m.
The top storey extension will be in the same character as most dwelling along preservation drive where they have built 2 storey buildings to take advantage of the unobstructed sea views and northerly aspect.
the new proposal will not be adversely effected by the abutting road any more than the existing building was effected by noise because the new balcony/deck is actually set back further away from the road than the existing out door entertain area was. All windows will be replaced with double glazing to lessen the effect of noise within the dwelling also.
Discretion is requested for the garage setback, because although the separation to the boundary is only 3356, the new crossover at the roadside kerb is 8956 due to the extensive nature strip. There is also another existing crossover at the primary frontage allowing for rear access to the existing shed and plenty of onsite parking and manoeuvrability.
P3:
The proposed extension has an modest separation from the neighbouring dwelling of 4 Hogarth road of approximately 10m. There is also an existing shed to the north of the existing neighbouring property and a fence that casts the majority of the shadow; As shown in red on the attached plans page a13. The private open space to the north/west of the neighbour still achieves ample sunlight from noon till sunset for the winter solstice. Considerations have been made in the design to try and reduce the overall height of the building by sloping the roof to the south and keeping the ceiling height and pitch as low as possible in the first storey extension.
10.4.6 Privacy for all dwellings
Objective:
To provide reasonable opportunity for privacy for dwellings.
P1: consideration has been given in relations to the balcony and deck within 3m of a side boundary in relation to privacy and overlooking. A timber privacy screen 1800h has been shown to alleviate any privacy concerns.
Window 6 of bedroom 4 is within 3m of a driveway and has a sill height less than 1.7m. As such shall be white glass to minimise direct view.
10.4.12 Setback of development for sensitive use
Objective:
Development for a sensitive use is to –
(a) Minimise likelihood for conflict, interference, and constraint between the sensitive use and the use or development of land in a zone that is not for a residential purpose; and
(b) Minimise unreasonable impact on amenity of the sensitive use through exposure to emission of noise, fumes, light and vibration from road, rail, or marine transport
P2:
The proposed extension within proximity to the railway is within the existing footprint of the existing dwelling so shouldn’t increase the impact. All windows will be replaced with double glazing to lessen the effect of noise within the dwelling also.
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Cover Page
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A00
COVER PAGESITE PLAN
ISOMETRIC VIEWSEXISTING FLOOR PLAN
PROPOSED FLOOR PLANSELEVATION 1 & 2ELEVATION 3 & 4
SETOUT PLANROOF PLAN
INTERNAL PLUMBING PLAN GFINTERNAL PLUMBING PLAN FF
WINDOW SCHEDULEDOOR SCHEDULE
SHADOW PLAN
SITE INFORMATION
LAND TITLE REFERENCE: 148311/2WIND CLASSIFICATION: N3 ASSUMED SOIL CLASSFICATION: M ASSUMEDCLIMATE ZONE: 7 BAL LEVEL: TBC ALPINE OR SUB-ALPINE AREA: N/ACORROSION ENVIRONMENT: <100m AWAY OTHER HAZARDS: N/APID: 2745882ZONING: GENERAL RESIDENTIAL
AREA SCHEDULE
SITE AREA: 702m2EXISTING FLOOR AREA: 143.4m2/15.42SQ.PROPOSED GROUND FLOOR AREA: 156.5m2FIRST FLOOR AREA: 132.3m2PROPOSED TOTAL FLOOR AREA: 288.8m2/31.07SQ.BALCONY AREA: 18.1m2PERVIOUS SURFACE= 238.4m2/34%
A00A01A02A03A04A05A06A07A08A09A10A11A12A13
Proposed Extension AT 2 Hogarth rd, Sulphur CreekFOR Nick & Monique Moore
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Site Plan
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A01Site PlanScale: 1 : 200
SITE PLAN LEGEND & NOTES:
GENERAL NOTES:DURING CONSTRUCTION SOIL AND WATER IS TO BE APPROPRIATELY MANAGED. THIS INCLUDES THE PROVISION OF SILT FENCING, FILTER SCREENS OR DEDICATED SILT TRAPS TO PREVENT DISCHARDGE OF GRAVEL, SOIL OR OTHER DEBRIS TO ANY EXISTING WATER COURSE OR ADJOINING PROPERTY DURING THE CONSTRUCTION PROCESS.
EXCAVATION:ALLOW FOR BULK EXCAVATION WHERE REQUIRED AND ALL EXCAVATION, FILLING, BACK FILLING AND CONSOLIDATION REQUIRED FOR THE FOOTINGS AND SLAB, RETAIN ALL ACCESS AND SERVICES INDICATED. MAKE GOOD.
SETTING OUT:THE CLIENT IS RESPONSIBLE FOR VERIFYING THE BOUNDARY PEGS ARE IN THE CORRECT LOCATION, MARKED AND CLEARLY VISIBLE FOR THE BUILDER.THE BUILDER SHALL ACCURATELY SET-OUT THE WORKS AND VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING ANY WORKS. AND SHALL MAKE GOOD AT HIS OWN EXPENSE ANY ERRORS ARISING FROM INACCURACIES OF THE SETOUT.
PROTECTION WORK:(SECTION 121 OF THE BUILDING ACT) IF EXCAVATION IS TO A LEVEL BELOW THAT OF THE ADJOINING OWNER'S FOOTINGS, ALONG THE TITLE BOUNDARY OR WITHIN 3 METRES OF A BUILDING BELONGING TO AN ADJOINING OWNER, THE BUILDER MUST (AS A MINIUMUM) PROVIDE AND MAINTAIN A GUARD TO SUPERVISE THE EXCAVATION. ADJOINING OWNER TO BE NOTIFIED USING FORM 6 (BUILDING AND PROTECTION WORK NOTICE) BY THE BUILDING SURVEYOR.
DRIVEWAY:EXPOSED AGGREGATE 120mm THICK 25MPa CONCRETE WITH SAW CUTS AT 4000mm CRS, 24 HOURS AFTER POURING. AGGREGATE STYLE AND FINISH TO BE CONFIRMED BY OWNER
LAWN
NEW COURTYARD
EXISTING SHED
EXIS
TING
DRI
VE
NEW DRIVEWAY
LAWN
NEW PRIVACY FENCE 1800 HIGH TIMBER SLATES
GATE
NEW CONCRETE PATH 1200 WIDE
EXISTING ALFRESCO TO BE REMOVED
REMOME EXISTNG CONCRETEFOR NEW GARDEN NATURE STRIP
EXISTING
NEW CROSS OVER
NEW DECK/BALCONY
EXISTING RESIDENCE EXISTING PORCH TO BE REMOVED
EXISTING CHIMNEYS TO BE REMOVED
PROPOSED EXTENSION OUTLINE
PROPOSED FIRST FLOOR OUTLINE
HO
GAR
TH S
T
PRESERVATION DRIVE NEIGHBOUR
NEIGHBOUR
EXIS
TIN
G 1
50 P
VC S
EWER
MAI
N
EXISTING 150 PVC SEWER MAIN
EXIS
TIN
G 1
00 A
BS W
ATER
MAI
N
EXISTING 100 ABS WATER MAIN
ASSU
MED
STO
RM
WATE
R M
AIN
CU
LVER
T
2222
2838
3370
BUILDIN
G ENVE
LOPE
30.18m
9.48
m
4.91m
32.30
m25
5°56
'00"
0.43m123°52'
9.39m
155°52'00"
11.3
1m
16.7
6m
186°
46'0
0"
2702m2
8956
6000
CROSS O
VER
3600REDUCE WIDTH OF EXISTING CROSS OVER TO STANDARD 3600 AS SHOWN
north SITE SERVICES:
ELECTRICITY, GAS, TELEPHONE, WATER, STORMWATER & SEWER SERVICE LOCATIONS ARE TO BE DETERMINED ON SITE & CONNECTED AS PER LOCAL AUTHORITY REQUIREMENTS.
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Isometric views
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A02Isometric viewsScale: 1 : 100
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Existing Floor Plan
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A03
RED DASHED WALLS TO BE REMOVED
RED DASHED DOORS TO BE REMOVED
REPLACE EXISTING WINDOWS WITH NEW DOUBLE GLAZED
RENOVATE BATHROOM. REMOVED VANITY AND BATH
REMOVE KITCHEN
PATCH PLASTER WORK AS REQUIRED, REMOVE ALL CORNICES MAKE SQ SET
REMOVE LAUNDRY
Existing Floor PlanScale: 1 : 100
north
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Proposed Floor Plans
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A04
FIRST FLOOR PLAN GROUND FLOOR PLAN
FLOOR PLAN LEGEND:W## WINDOW MARKERD## DOOR MARKERHW HOTWATER CYLINDER WO WALL OVENDW DISH WASHERF FRIDGEWM WASHING MACHINEHPU HEAT PUMP UNITPAN PANTRY
LIFT DUMB WAITER
R2.0 INSULATION BATTS REQUIRED TO INTERNAL WALLS SEPARATING WET AREAS TO HABITABLE ROOMS. FOR SOUND SEPARATION AS PER NCC 3.8.6 NOT LESS THAN 50 DENSITY RwR2.0 INSULATION BATTS REQUIRED TO INTERNAL WALLS OF THE GARAGE FOR THERMAL PERFORMACE AS PER NCC 3.12.1.6
POSTS & COLUMNS:
C1: TIMBER/STEEL POSTTO ENGINEERS SPECIFICATIONS
INTERNAL INSULATION:
NOTE- DIMENSIONS ARE TO STUDWORK ONLY NOT INCLUDING CLADDING AND CAVITY
ROOF LINE ABOVE
13400
6009320
1301
011
0014
004550
9420
48704550
5370
140
7080
130
6720
140
6950
7260
2000
9060001301830130930
1304020140
5500
130
3380
130
3690
14012
0025
0090
140
1200
3980
1403300901200
1304420140
90 4460 90120090 3900 90
7040 900 1200 600 90
9320
9725
4385
90 2100 90 2270 90 4590 90
3350 1110 129090 1800 2100 90
9042
9590
1115
9072
4090
9037
0039
5590
1800
9017
7517
0082
090
GARAGE
BATH
WCWIR
BED 2
BED 3
BED 4
RUMPUS
LIVING
DINING
KITCHEN
WIPLINEN
HALLWC
ENS' WIR
BED 1 LAU
N
UP
STORE UNDER
BIRBIR
PATH
DECK
STORE
BALCONY
DWN
F
DW
WO
RHGAS
1360
NEW CPT.
NEW CPT.
NEW TLS.
CNC.
CPT.
CPT.
CPT.TLS.
TLS.
TLS.
TLS.
TLS.
CPT.STAIRS
DECK
HW
C1 C1
LIFT
68090
1230
1130
2690
1300
LIFT
D1
D2
D3
W2
W3
W4
W5
W6
W7
D4
W8
W1
W9
W10
W11
W12
W13
W14
W15
W16
D5
W17
W18
W19
D6
D7
D7
D7
DRAFT SEAL ON DOOR
D6
D08
2285
90
900
Proposed Floor PlansScale: 1 : 100
north
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Elevations 1 & 2
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A05
FCL
FFL
FRL
FFCL
FFL27
0024
00
7421
FCL
FFL
FRL
FFCL
FFL
GLASS BALUSTRADE 1M HIGHTO NCC 3.9.2
TIMBER PRIVACY SCREEN 1800H
BLOCK WALL TEXTURE COAT
COLORBOND MONUMNET ROOFING, GUTTER AND FLASHINGS SCYON STRIA 325 CEMENT SHEET
CLADDING SELECTED WHITEBUILDING ENVELOPE
BUILDING ENVELOPE
1067
1592
D1 W1 W8D2
W9W10W11
W12
W7D4
D5
W18W19
W17
East ElevationScale: 1 : 100
1 North ElevationScale: 1 : 100
2
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Elevations 3 & 4
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A06
FCL
FFL
FRL
FFCL
FFL
2700
2400
7421
FCL
FFL
FRL
FFCL
FFL
SCYON STRIA 325 CEMENT SHEET CLADDING SELECTED WHITE
BLOCK WALL TEXTURE COAT
BUILDING ENVELOPE
1041
BUILDING ENVELOPE
W13
D3W2W3
W4W5W6
W16 W15 W14
FROST GLASS TO W6West ElevationScale: 1 : 100
3 South ElevationScale: 1 : 100
4
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Setout Plan
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A07Setout PlanScale: 1 : 200
STEPLESS SHOWER:
FLOOR TRUSSES REBATED FOR SHOWER BASE TO ENSURE APPROPRIATE FALL IS ACHIEVED 1:50. STAINLESS STEEL GRATE DRAIN RL -20 BELOW FLOOR LEVEL. (REFER TO A17 FOR WATER PROOFING DETAILS)
EXTERIOR CONCRETE:
REBATE PORCH RL -50 BELOW FLOOR LEVEL. SLOPE AWAY FROM BUILDING TO ENSURE APPROPRIATE FALL IS ACHIEVED 1:50 FOR WATER RUNOFF . (REFER TO ENGINEERING PLANS DETAILS)
LIFT VOID
STAIR VOID
GRO
UN
D FLO
OR PLA
N
EXIS
TING
FLOO
R PLA
N
FIRST FLO
OR PLA
N
north
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Roof Plan
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A08
ROOF PLAN NOTES:
GUTTERS AND DOWNPIPES TO AS3500. MAXIMUM CENTRES FOR DOWNPIPES TO BE 12M.
ROOF STRUCTURE:
CUSTOM ORB ROOFING IN COLOR & PERMIABLE SARKING TIMBER TRUSSES TO MANUFACTURES SPECIFICATIONS
EAVES VENTS WITH ALUMINUM MESH BACKING AT INTERVALS AS SHOWN (2500mm MAX. CENTRES).
ROOF PLUMBING:GENERIC QUAD 150 HIGH FRONT GUTTERIN COLOR AND FASCIA
COLORBOND COLOR CAPPINGSAND FLASHINGS
D.P. 100 x 50 UPVC SQUARE DOWNPIPESCOLOR FINISH
D.P.S 100 x 50 UPVC SQUARE DOWNPIPES & SPREADERCOLOR FINISH
NOTES:BATTENS TYPICALLY 70 X 35 DEEP HARDWOOD @600MAX. CENTRES. (USE F5 KD TREATED PINE IFBATTENS ON TOP OF SARKING).
SEE BCA VOL. 2 FIGURE 3.5.1.5 DIAGRAM B FORDEFINITION OF INTERNAL AND END SPANS.
VAPOUR PERMEABLE SARKING INSTALLED AS PERMANUFACTURER'S INSTRUCTIONS. ENSURE THERE IS ACLEAR UNIMPEDED PATH OF TRAVEL FOR WATER TOESCAPE FROM SARKING INTO THE EAVES GUTTER.ADDITIONAL BATTENS OR BLOCKING PIECES MAY BEREQUIRED.
SARKING MUST COMPLY WITH AS/NZS 4200 PARTS 1AND 2.
DOWNPIPES MUST NOT SERVE MORE THAN 12M OFGUTTER LENGTH FOR EACH DOWNPIPE.
ROOF CLADDING TO COMPLY WITH AS 1562.1.
ROOF DRAINAGE MUST COMPLY WITH:- PLUMBING CODE OF AUSTRALIA PART D1- AS/NZS 3500.3- BCA VOLUME 2 PARTS 3.1.2 AND 3.5.2.(DEEMED TO SATISFY PROVISIONS)
450
DP DPDP
Roof PlanScale: 1 : 100
north
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Internal plumbing plan ground floor
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A09
LEGEND & NOTES Stormwater line (100mm UPVC)
Sewer line (100mm UPVC)
Water line (100mm UPVC)
Install inspection openings at major bends forstormwater and all low points of downpipes.
All plumbing & drainage to be in accordance with localCouncil requirements.
Provide surface drain to back of bulk excavation to drainlevelled pad prior to commencing footing excavation.
ServicesThe heated water system must be designed andinstalled with Part B2 of NCC Volume Three -Plumbing Code of Australia.
Thermal insulation for heated water piping must:a) be protected against the effects of weather andsunlight; andb) be able to withstand the temperatures within thepiping; andc) use thermal insulation in accordance with AS/NZS4859.1
Heated water piping that is not within a conditionedspace must be thermally insulated as follows:1. Internal pipinga) All flow and return internal piping that is -
i) within an unventilated wall spaceii) within an internal floor between storeys; oriii) between ceiling insulation and a ceiling
Must have a minimum R-Value of 0.2 (ie 9mm of closed cellpolymer insulation)
2. Piping located within a ventilated wall space,an enclosed building subfloor or a roof spacea) All flow and return pipingb) Cold water supply piping and Relief valve pipingwithin500mm of the connection to central waterheating systemMust have a minimum R-Value of 0.45 (ie 19mm of closedcell polymer insulation)
3. Piping located outside the building or in anunenclosed building sub-floor or roof spacea) All flow and return pipingb) Cold water supply piping and Relief valve pipingwithin500mm of the connection to central waterheating systemMust have a minimum R-Value of 0.6 (ie 25mm of closedcell polymer insulation)
Piping within an insulated timber framed wall, such asthat passing through a wall stud, is considered tocomply with the above insulation requirements.
– AIR ADMITTANCE VALVE
LEGEND:AAVEVI.OORG
EDPI.SFC
– EDUCT VENT– INSPECTION SHAFT OPENING– OVERFLOW RELIEF GULLY
– EXISTING DOWN PIPE– INSPECTION SHAFT– FLEXIBLE CONNECTOR
FWG - FLOOR WASTE GULLY (NO SMALLER THAN DN40 UNTRAPPED)
- NEW DOWN PIPENDP
(TPRV FROM HWC CONNECTED INTO STORMWATER)
ORG rim to be minimum 150mmbelow lowest sanitary fitting.
I.OREEVI.O
EXISTING SEWER LINE
CONNECT NEW SEWER DRAINAGE INTO EXISTING AS SHOWN
CAUTION UNDER GROUND SEWER PIPIING IN VINCINTY, DIVERT EXISTNG SEWERLINE AROUND NEW EXTENSION
VD
REEVI.O
I.O
E.D.P
N.D.PN.D.P
E.D.P
NEW PVC STORMWATER
CONNECT NEW STORMWATER INTO EXISTING DRAINAGE AS SHOWN
ORG
EXISTING STORMWATER LOCATION UNKNOWN, TO BE SITE VERITIED
N.D.P
Internal plumbing plan ground floorScale: 1 : 100
north
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Internal plumbing plan first floor
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A10
LEGEND & NOTES Stormwater line (100mm UPVC)
Sewer line (100mm UPVC)
Water line (100mm UPVC)
Install inspection openings at major bends forstormwater and all low points of downpipes.
All plumbing & drainage to be in accordance with localCouncil requirements.
Provide surface drain to back of bulk excavation to drainlevelled pad prior to commencing footing excavation.
ServicesThe heated water system must be designed andinstalled with Part B2 of NCC Volume Three -Plumbing Code of Australia.
Thermal insulation for heated water piping must:a) be protected against the effects of weather andsunlight; andb) be able to withstand the temperatures within thepiping; andc) use thermal insulation in accordance with AS/NZS4859.1
Heated water piping that is not within a conditionedspace must be thermally insulated as follows:1. Internal pipinga) All flow and return internal piping that is -
i) within an unventilated wall spaceii) within an internal floor between storeys; oriii) between ceiling insulation and a ceiling
Must have a minimum R-Value of 0.2 (ie 9mm of closed cellpolymer insulation)
2. Piping located within a ventilated wall space,an enclosed building subfloor or a roof spacea) All flow and return pipingb) Cold water supply piping and Relief valve pipingwithin500mm of the connection to central waterheating systemMust have a minimum R-Value of 0.45 (ie 19mm of closedcell polymer insulation)
3. Piping located outside the building or in anunenclosed building sub-floor or roof spacea) All flow and return pipingb) Cold water supply piping and Relief valve pipingwithin500mm of the connection to central waterheating systemMust have a minimum R-Value of 0.6 (ie 25mm of closedcell polymer insulation)
Piping within an insulated timber framed wall, such asthat passing through a wall stud, is considered tocomply with the above insulation requirements.
– AIR ADMITTANCE VALVE
LEGEND:
AAVEVI.OORGDPFC
– EDUCT VENT– INSPECTION SHAFT OPENING– OVERFLOW RELIEF GULLY– DOWN PIPE – FLEXIBLE CONNECTOR
FWG - FLOOR WASTE GULLY (NO SMALLER THAN DN40 UNTRAPPED)
- VERTICAL DROPPERVD
(TPRV FROM HWC CONNECTED INTO STORMWATER)
AAV
I.OVD
EVREI.O
FWD
Internal plumbing plan first floorScale: 1 : 100
north
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Window Schedule
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A11
FLYSCREENS TO BE FITTED TO ALL OPENABLE WINDOWS AND DOORS.REFER TO ENERGY ASSESSMENT FOR GLAZING U-VALUE AND SHGC REQUIREMENTS
SHOWER SCREENS 1800H SEMI-FRAMELESS SHOWER SCREENS TO COMPLY WITH BCA TABLE 3.6.5. & AS1288.
MINIMUM 4MM THICK GRADE A TOUGHENED SAFETY GLASS, LABELLED TO COMPLY WITH INDUSTRY STANDARDS.
OPAQUE BANDSWHERE GLAZED DOORS OR SIDE PANELS ARE CAPABLE OF BEING MISTAKEN FOR A DOORWAY OR OPENING, THE GLASS MUST BE MARKED TO MAKE IT READILY VISIBLE AS FOLLOWS:- MARKING IN THE FORM OF AN OPAQUE BAND NOT LESS THAN 20MM IN HEIGHT;- THE UPPER EDGE IS NOT LESS THAN 700MM ABOVE THE FLOOR;- THE LOWER EDGE IS NOT MORE THAN 1200MM ABOVE THE FLOOR.
FLASHINGS TO WALL OPENINGSALL OPENINGS MUST BE ADEQUATELY FLASHED USING MATERIALS THAT COMPLY WITH AS/NZS 2904.REFER TO SECTIONS FOR WINDOW HEAD AND SILL DETAILS. FLASHING TO BE INSTALLED WITH GLAZING MANUFACTURER'S SPECIFICATIONS FOR BRICK VENEER CONSTRUCTION. PROTECTION OF OPENABLE WINDOWS.A WINDOW OPENING MUST BE PROVIDED WITH PROTECTION, IF THE FLOOR BELOW THE WINDOW IN A BEDROOM IS 2M OR MORE ABOVE THE SURFACE BENEATH.PROTECT THE WINDOWS (IDENTIFIED IN THE TABLE BESIDE) BY ONE OF THE FOLLOWING METHODS:a) A DEVICE CAPABLE OF RESTRICTING THE WINDOW OPENING; ORb) A SCREEN WITH SECURE FITTINGS.THE DEVICE OR SCREEN MUST:a) NOT PERMIT A 125MM SPHERE TO PASS THROUGH THE WINDOW OPENING OR SCREEN; ANDb) RESIST AN OUTWARD HORIZONTAL ACTION OF 250N AGAINST THE:WINDOW RESTRAINED BY A DEVICE; ORSCREEN PROTECTING THE OPENING; ANDc) HAVE A CHILD RESISTANT RELEASE MECHANISM IF THE SCREEN OR DEVICE IS ABLE TO BE REMOVED, UNLOCKED OR OVERRIDDEN.
ALL GLAZED WINDOW & DOOR ASSEMBLIES IN EXTERNAL WALLS TO COMPLY WITH AS 2047. ALL OTHER GLASS TO COMPLY WITH AS 1288.
WINDOW # TYPE HEAD HEIGHT TOTAL DIMENSIONS OPENABLE DIMENSIONS FRAME FRAME FINISH &
COLOUR GLAZING HARDWARE INTERIOR ARCHITRAVE
GROUND FLOOR
W01 FIXED 2100mm 2100mm x 1070mm N/A 20mm ALUMINIUM SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED
STANDARD GLASS N/A 67 x 18 PRE-PRIMED ARCHITRAVE PAINT FINISH
W02 AWNING 2100mm 900mm x 700mm 900mm x 700mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W03 AWNING 2100mm 900mm x 500mm 900mm x 500mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W04 AWNING 2100mm 900mm x 2600mm 2/900mm x 1300mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 2x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W05 AWNING 2100mm 900mm x 2600mm 2/900mm x 1300mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 2x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W06 AWNING 2100mm 900mm x 3520mm 2/900mm x 1760mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED FROST GLASS 2x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W07 FIXED 2100mm 2100mm x 2400mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W08 FIXED 2100mm 2100mm x 2100mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
FIRST FLOOR
W09 AWNING 1700mm 900mm x 2100mm 900mm x 2100mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W10 FIXED 1700mm 900mm x 3000mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W11 AWNING 1700mm 900mm x 1800mm 900mm x 1800mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W12 FIXED 2100mm 1500mm x 3000mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W13 AWNING 2100mm 600mm x 1800mm 600mm x 1800mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W14 AWNING 2100mm 900mm x 1800mm 900mm x 1800mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W15 AWNING 2100mm 900mm x 900mm 900mm x 900mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 1x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W16 AWNING 2100mm 900mm x 3600mm 2/900mm x 1800mm20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS 2x AWNING WINDER 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W17 FIXED 2100mm 2100mm x 4000mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W18 FIXED 3300mm 900mm x 4000mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
W19 FIXED 3300mm 900mm x 4000mm N/A20mm ALUMINIUM
SCYON AXCENT TRIM MONUMENT MATTE DOUBLE GLAZED STANDARD GLASS N/A 67 x 18 PRE-PRIMED
ARCHITRAVE PAINT FINISH
WINDOW SCHEDULEAll window sizes to be checked and measured on site
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Door Schedule
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A12
DOOR # TYPE HEAD HEIGHT TOTAL DIMENSIONS FRAME GLAZING HARDWARE INTERIOR ARCHITRAVE
GROUND FLOOR
D01 EXTERNAL SWING DOOR 2100mm 2100mm x 1070mm POWDERCOAT
MONUMENT MATT N/A LEVER HANDLE WITH LOCK
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
D02 PANEL LIFT GARAGE DOOR 2100mm 2100mm x 5000mm TIMBER N/A MOTOR & REMOTE
CONTROL
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
D03 EXTERNAL SWING DOOR 2100mm 2100mm x 920mm POWDERCOAT
MONUMENT MATTSINGLE GLAZED
STANDARD GLASSLEVER HANDLE
WITH LOCK
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
D04 EXTERNAL SLIDING DOOR 2100mm
2100mm x 4000mm POWDERCOAT MONUMENT MATT
DOUBLE GLAZED STANDARD GLASS
SIDE HANDLE WITH LOCK
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
D08 INTERNAL CAVITY SLIDER 2100mm
2100mm x 1440mm TIMBER N/A SIDE HANDLES
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
FIRST FLOOR
D05 EXTERNAL SLIDING DOOR 2100mm
2100mm x 4000mm POWDERCOAT MONUMENT MATT
DOUBLE GLAZED STANDARD GLASS
SIDE HANDLE WITH LOCK
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
D06 INTERNAL SWING DOOR 2100mm
2100mm x 820mmTIMBER N/A LEVER HANDLE
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
D07 INTERNAL CAVITY DOOR 2100mm
2100mm x 820mmTIMBER N/A LEVER HANDLE
67 x 18 PRE-PRIMED ARCHITRAVE PAINT
FINISH
DOOR SCHEDULEAll door sizes to be checked and measured on site
PROJECT NAME
Proposed Extension
REV DATE DESCRIPTION
PROJECT ADDRESS
2 Hogarth rd, Sulphur Creek
CLIENT
Nick & Monique MoorePROJECT NO.
19023
PAPER SIZEA3
DOCUMENT DATE29/10/2019
DOCUMENT PHASE
Development Approval
DRAWING TITLE
Shadow Plan
DRAWNC.O
eclo
.des
igns
@ou
tlook
.com
0419
3877
46
ACCREDITATIONCC6669
1 12/12/20 modifications
2 04/03/20 modifications
A13Shadow PlanScale: 1 : 500
9.00AM winter solstice 21/june 12.00PM winter solstice 21/june 3.00PM winter solstice 21/june
9.00AM summer solstice 21/dec 12.00PM summer solstice 21/dec 3.00PM summer solstice 21/decnorth