    1 Safety remarks 4

    2 System description

    Access in general 6

    Fields of application 6

    Performance features 6

    System overview 7

    3 System structure, conductor material and range

    General planning information 8

    Planning areas 8

    Supply limits ATLC/NG 670-… 9

    Permitted conductor material 9

    Network LAN 10

    Cabling structure/areas 10

    Power over Ethernet (PoE) 10

    Network characteristics 10

    Cabling for indoor devices 11

    Cameras 12

    Pick-up range of the camera 13

    Location of the video camera 13

    4 System components

    Overview 18

    Door stations (outdoor/indoor area) 20

    Access cameras 24

    External cameras 25

    Indoor stations (audio/video) 26

    Accessory 28

    Distribution components – Door controller 29

    Distribution components – Active/passive system expansion 30

    Distribution components – Line rectifiers 31

    Distribution components – Transformers 32

    Space requirements in distribu-tion boards/IT cabinets (19 inch) 33

    Access server variants 34

    Minimum requirements – Server hardware / Virtual machine 36

    System conditions Access Professional 37

    Additional requirements imposed on virtualization 37

    Network security 38

    Client-Software 38

    App 39

    Software integration for non-Siedle systems 39

    Upgrade (server) 39

    Access licences 40

    Microsoft licences (CAL) 43

    5 Function overview 44

    6 Configuration – Access System

    Models 48

    Server administration – device parameters 51

    Button functions 53

    7 Access control through the Vario bus

    Ranges in the Vario bus 60

    Distribution components – Transformers 62

    Modules 63

    Distribution components – Server/controller 64

    8 Access circuit diagrams

    Overview 66

    Switching outputs/inputs 68

    8.1 Siedle Vario 70

    8.2 Access custom-fit door loudspeaker 98

    8.3 Siedle Classic 104

    8.4 Siedle Steel 114

    8.5 Camera connection 126

    8.6 Storey call button 130

    9 Commissioning and operation

    Commissioning 132

    Commissioning requirements 132

    Commissioning instruction 132

    Recommendation 133

    Operating manual 133

    Updates and maintenance 133

    Maintenance contract 133

  • 3

    RemarksThis document serves as a guide for the planning and technical implementation of the Siedle Access system. It is designed to provide an overview of the key points that need to be observed.

    This document supplements and is supplemented by the Access server commissioning instructions.To supplement this system manual, you will find the latest edition in the download area of our website on www.siedle.com

    For complex systems or special requirements, the technical consult-ants in Project Sales will be pleased to advise you.(For detailed information, see page 153)

    We accept no liability for modi-fications, mistakes or printing errors.Modifications / additions, mistakes or printing errors do not form grounds for any claim to compensa-tion for damages.

    10 Servicing

    Service requirement 134

    Warranty 134

    Exchanging devices 134

    Exchanging ATLM/ATLE 670-… 134

    Exchanging a defective server AS 670-…/ASH 670-… 134

    Update process 134

    Start process 134

    Initial commissioning/Login 135

    Registration at the administrator user interface 135

    LED displays 136

    Terminal connections and meas-ured values 138

    11 Glossary 140

    12 Index

    Access components 150

    Access topics 151

    13 Siedle service

    Customer support and cus-tomer advice/Siedle centres 152

    After-sales service 153

  • 4

    1 Safety remarks

    Electrical voltage

    Mounting, installation and servicing work on electrical devices may only be performed by a suitably qualified electrician.Failure to observe this regulation could result in the risk of serious damage to health or fatal injury due to electric shocks.

    Devices with 230 V connection In accordance with DIN VDE 0100 part 410, section 411.1.3 attention must be paid to ensuring a safe sepa-ration between system lines and the mains voltage; i.e. system and mains cores must not be permitted to touch! The system line cable (extra-low safety voltage) must be stripped back by the minimum possible.

    Electrostatic charging

    As a result of electrostatic charging, direct contact with the circuit board can result in destruction of the device. Direct contact with the circuit board must therefore be avoided.

    • When working at the device, observe the remarks relating to mains cut-off.• Observe the DIN EN 60065 standard! When establishing the electronic connection, observe the requirements of VDE 0805 or EN 60950.• The building installation must include an all-pole mains switch with a contact separation of at least 3 mm.• Ensure maximum fusing of 16 A for the mains connection in the building installation.• When planning large-scale (complex) systems, the distributor space required for the switch panel mounting devices must be taken into consideration in the distributor planning process. • No external voltages >30 V AC/DC may be applied to system users.

    Electrical distribution boards and IT cabinet systems

    Please make sufficient provisions in the electrical distribution boards/IT cabinet system for later expansion, changes or subsequent disassembly (service/maintenance).

    Plan the electrical distribution board/the IT cabinet system so that the heat generated by all installed com-ponents is adequately dissipated and cannot impair any functions or cause damage to the components or infra-structure at the installation site.

    During planning, take the applicable legal provisions, standards, directives and safety instructions for the opera-tion/installation site into account.

    All system components which are designed for/suitable for installation in an electrical distribution board or in an IT cabinet system/housing may only be installed in the permitted installation position according to the enclosed product information.If system components are operated in improper installation positions or with improper operating parameters (e.g. excessive ambient tempera-ture), this will render their warranty rights void in the event of service.

  • 5

    Legal notice Photographs of individuals taken without their knowledge may not be published or stored in publicly acces-sible video memory facilities.Individuals who have been photo-graphed without their knowledge are entitled to request that pictures be deleted based on the right of persons to their own likeness. Never store pictures of persons you do not know in social networks or send them by email to others/public groups. This will infringe their per-sonal rights.If stored images are used as part of private / criminal law proceedings or in a police investigation, this requires prior clarification with a lawyer or the responsible police authority. Photographs of individuals taken without their knowledge may not be published or stored in publicly acces-sible video memory facilities.Individuals who have been photo-graphed without their knowledge are entitled to request that pictures be deleted based on the right of persons to their own likeness. Never store pictures of persons you do not know in social networks or send them by email to others/public groups. This will infringe their per-sonal rights.If stored images are used as part of private / criminal law proceedings or in a police investigation, this requires prior clarification with a lawyer or the responsible police authority.The legally admissible operation and installation of this device and all its system components (hardware and software) are the responsibility of the user and not of the device manufacturer.

    Protect your network! Only use up-to-date components and terminals in the network in line with the latest state of the art. Regularly update the operating sys-tems of all components and termi-nals. Exchange obsolete components and terminals for up-to-date models. Use professional protective software (antivirus, firewall, …) in all termi-nals. Issue secure passwords. Secure your network with the highest secu-rity standards available in the net-work. Protect your network against unauthorized attack from inside and outside.

    Protect your property! The Siedle App can be used from any location as a door release! Keep smartphones/tablets on which the Siedle App is activated safe from theft. Protect these devices against unauthorized usage with a code/password/fingerprint. Always use the latest protection mechanisms avail-able for your smartphone/tablet.

  • 6

    Access in general Siedle Access is a server-based IP system for building communication. It offers the whole breadth of Siedle communication system functionality, from the speech or video connec-tion through concierge functionality to complex switching and control functions. Access works in its own IP network.Central management on the Access server permits configuration and administration both over the web browser and remotely. In addition, it facilitates system upgrading by adding and exchanging devices or licence models (e.g. function licences, licences for the use of external makes such as VoIP tel-ephones).The system utilizes the network protocols TCP/IP and UDP, as well as SIP for internet telephony (VoIP), extended to include an access-specific data protocol. The audio encoding standard (G.711) and video encoding standard (H.264) guarantee high picture and tone quality with minimal network loading.

    Fields of application Projects with• a large number of users (door stations and/or indoor devices) and long distances• stringent demands on audio and video transmission• several (also geographically) sepa-rate building sections• concierge and surveillance func-tions• heterogeneous utilization (private and commercial mixed use)• fundamental requirement for structured cabling and IP technology

    2 System description

    Performance features Access offers• Simple planning and installation in conformity with standards• PC-based one-man commissioning• Use of door stations, indoor sta-tions, software clients or apps• Up to 320 users and 25 parallel video and speech channels (full-duplex voice connections) per Access server• Worldwide accessibility with secure door call via Siedle app on iPhone or iPad• An efficient PC-based concierge workstation with video surveillance function• Server for central system manage-ment and update function• Indoor devices that are supplied via PoE (Power over Ethernet) according to IEEE802.3af• Extensive audio/video communica-tion, control and security functions in and outside the Access system• Connection of different commu-nication and control platforms (VoIP, KNX, etc.)• System can be linked to public net-work telephony and telephone sys-tems conforming to the SIP standard• Connection of selected third-party hardware (VoIP TC systems, VoIP telephone, IP cameras (only for app), KNX gateways)• Integration of SIP audio, SIP video and a/b telephones• Integration of external cameras• Intercom functionality• Function extensions via optionally available licences• Call rerouting, call forwarding and call follow-me function• Call differentiation in terminals• Door call via call display or code lock keypad• Storey door loudspeaker (with and without video) and storey door release• Display of messages, statuses, or arriving calls in plain text on devices with displays• Scan mode for connected cameras• Optional group formation (e.g. for announcements)

    • Call storage facility with call list and video memory• Polyphonic ringtones

    Remarks From Access V 3.1.0, the inte-gration and operation of a building automation server (JUNG Facility Pilot Server) is possible using the Access Video Panel. Please note that the building automation server (JUNG Facility Pilot Server) is not a constituent part of the Siedle Access system. Advisory services and the sale of hardware and licences take place exclusively through ALBRECHT JUNG GmbH & Co. KG.

  • 7

    ATLC/NG 670

    ASHT

    10:1012 1 20.05.2013Start 08:00 | 16.12.2014

    AVP

    AHTV AHF AHFV

    Router

    Internet

    Internet

    Internet

    iPhone

    iPad

    iPad

    iPhone

    Router

    Internet

    ASHT

    ASC

    iPad

    iPhone

    Public mobil network

    Public WLAN

    Local network

    Local telephone networkLocal Access network

    Door station

    Access serverSwitch

    Switch

    SIP telephone SIP telephone SIP telephone SIP telephone SIP telephone

    SIP telephone system

    Door release

    WLAN

    WLAN

    Access gateway

    Switch Customer server(e.g. mail server)

    3G / 4G

    System overview

  • 8

    3 System structure, conductor material and range

    General planning information The basis for planning an Access system is an IP network configured in accordance with specifications for creating structured cabling (as described under Network cabling).The purpose of the Access security concept is to ensure that network cabling terminates not outside the door but with the ATLC/NG 670-… Consequently, the door connection (as described under cabling in the door area) is not a constituent part of the IP network.For positioning of the Access devices and network components, it is advis-able to provide a construction plan. This should take into consideration the length restrictions of the con-nection types such as copper and optical fibres. The space requirement of network components and Siedle devices must be determined and taken into consideration. Siedle recommends drawing up a schematic drawing of the network structure and the used Siedle devices.

    ATLC/NG 670-… ATLC/NG 670-…(+ NG 602-…)

    max. 10 m

    Door station

    Camera

    Door area

    Network LAN

    Range depends on the installed conductor material.

    Network LAN

    Door release (Tö)

    Planning areas Generally speaking, a distinction is drawn between the door area and the protected local area network (LAN).

    Door area The installation for the door station is referred to as the door area. If cor-rectly installed, this area is protected from unauthorized access. From the outside, it is not possible to access the network.

    Logical and self-explanatory names should be assigned to the various devices, for example FL1AP5 for 1st floor, apartment 5. All cable seg-ments between active components should be listed in an index showing their name, cable length and cable type.In order to permit correctly con-trolled server shutdown, we recom-mend including a UPS (uninter-ruptible power supply) unit in the planning.

    Cabling in the door area The IP network terminates with the ATLC/NG 670-… To protect against unauthorized access, the ATLC/NG 670-… must be accommodated without fail inside the building.The cabling from the ATLC/NG 670-… to the door station is executed in the conventional way. Every door station/independent camera is installed in the system with its own ATLC/NG 670-…The cabling between the door release and ATLC/NG 670-… should be tamper-proof with a separate line (direct laying).If an external camera is used, the maximum distance between AIVS 670-… and the camera is 10 m. The AIVS 670-… requires a video input signal of 1 Vss.The following conductor materials with suitable maximum ranges have been officially approved for wiring between ATLC/NG 670-… and the door station:

  • 9

    Permitted conductor material

    Cable type Diameter Maximum range

    Telecommunications installation cable(Pair-twisted)

    J-Y(St)Y… dia. 0.8 mm 200 m

    J-Y(St)Y… dia. 0.6 mm 100 m

    Telecommunications outdoor cable (Quad-twisted)

    A-2Y(L)2Y… dia. 0.8 mm 200 m

    A-2Y(L)2Y… dia. 0.6 mm 100 m

    Network cable(Pair-twisted)

    Cat. 5 AWG22… dia. 0.644 mm 120 m

    Cat. 5 AWG23… dia. 0.573 mm 90 m

    Cat. 5 AWG24… dia. 0.511 mm 80 m

    Cat. 5 AWG26… dia. 0.405 mm 50 m

    Terminals Cable type – Pair-twisted Cable type – Quad-twisted

    ATLC/NG 670-0 Core Twin core Location Core Twin core Bundle

    S1 a1 1

    a1

    1S2 b b

    S3 a2 1

    a2

    S4 b b

    D1 a3 1

    a3

    2D2 b b

    V1 a4 1

    a4

    V2 b b

    Depending on the cable type, pair-twisted or quad-twisted, we rec-ommend the following connection methods for the cabling between the door station and ATLC/NG 670-0:

    Supply limits ATLC/NG 670-…

    Siedle Vario Video door stations Audio door stations

    Standard with COM 611-…

    with DRM 612-…

    Standard with COM 611-…

    with DRM 612-…

    ACM 67x-… 1 1 1 - - -

    ATLM 670-… 1 1 1 1 1 1

    COM 611-… - 1 - - 1 -

    DRM 612-… - - 1 - - 1

    BTM 650-… 10 1 1 26 12 12

    Siedle Classic/Steel

    ACM 67x-… 1 1 1 - - -

    CATLE/SATLM 670-… 1 1 1 1 1 1

    COM 611-… - 1 - - 1 -

    DRM 612-… - - 1 - - 1

    Call buttons 20 1 1 60 30 30

  • 10

    Network LAN The requirement for integration of an Access system is a network infra-structure created in accordance with the stipulations for generic cabling (from Category 5).Rules for generic cabling are set out in various standards:• DIN 50173-1 General requirementsFor individual building types, the fol-lowing standards apply in addition:• DIN 50173-2 (ISO/IEC 11801) for office buildings• DIN 50173-3 (ISO/IEC 24702) for industrially used locations• DIN 50173-4 (ISO/IEC 15018) for apartmentsInternationally, the ISO/IEC standards apply.

    Cabling structure/areas The cabling is broken down into 3 areas.

    Primary area • Fibre optic cables• Cabling between individual buildings and/or within buildings between several main building dis-tributors.• In the case of copper wire con-nections, adequate equipotential bonding must be guaranteed.

    Secondary area • Fibre optic cables• The storeys are networked by means of storey distributors. Both fibre optic and copper connections can be used. This is dependent upon the switches used and their distance from the main distributor/switch.

    Tertiary area • Twisted pair for fixed installation plus patch cable for cabling from the network junction box to the terminal.

    ATLC/NG 670

    ServerSwitch

    Door station

    Primary area

    Tertiary area

    Seco

    ndar

    y ar

    ea

    Door release (Tö)

    3 System structure, conductor material and range

    Network characteristics Access system• Maximum of 150 ms delay in one direction (one way delay)• Maximum of 300 ms total delay• Packet loss < 1%• Maximum of 20 ms jitter

    Power over Ethernet (PoE) The supply for the indoor stations must be ensured by the customer via PoE. Depending on the network infrastructure, the decentral PoE supply of individual devices can take place with PoE injectors, and the central PoE supply of several devices can take place with PoE-capable routers/switches. Routers/switches used must be PoE-capable according to IEEE802.3af.

  • 11

    Cabling for indoor devices All indoor devices are always con-nected via an RJ45 8/8 (or RJ45 socket modules 8(8)) network socket. This is divided into two sockets. The left-hand socket is reserved for the network (LAN area). The right-hand socket is independent of the network and is used for connecting other control elements permitting additional uses.Supplementary functions such as a storey call button are also connected via the RJ45 network socket (right-hand socket/side) or the RJ45 socket modules 8(8).The range between ERT and the indoor device is max. 50 m (Cat 5 AWG22).The Access indoor devices can be installed without problems using standard RJ45 flush mounting net-work junction boxes.In this case, simply install the net-work junction box without the frame and panel. The Siedle indoor device can be mounted above the junction box and connected to the network with a plug-in connector.

    If there is no flush mounted network socket at the required mounting height due to circumstances on site, the indoor call station can be surface mounted with the AZA 870-… In this case, the connection from the indoor call station to the network is established using a patch cable (not provided).

    If the indoor call station is intended for use as a table-top unit, the device can be converted using the AZTV 870-… with 3 metre long con-necting cable.

    165

    cm

    Eye level

    Junction boxRJ45

    Installation with patch cable

    150

    cm

    165

    cm

    Eye levelJunction boxRJ45

    Installation on flush mounted junctio box

    Ideally, an RJ45 flush mounted junc-tion box should be positioned at the mounting height for the indoor device (display height less 15 cm).

    Mounting with Access surface mounting accessory AZA 870-… and patch cable provided on site.

  • 12

    3 System structure, conductor material and range Cameras

    External cameras Audio door station with external analogue camera: For the external camera, an AIVS 670-… and a matching separate power supply (e.g. NG 602…) is required.

    Separately operated external ana-logue camera: One AIVS 670-… and one ATLC/NG 670-… are required for each external analogue camera.

    25x23x2

    2Tö

    AIVS 670

    ATLC/NG 670-…NG 602-…

    Door stationCamera

    LAN

    24x23x23x22 2

    AIVS 670 AIVS 670

    ATLC/NG 670-…ATLC/NG 670-…(NG 602-…)

    ATLC/NG 670-…(NG 602-…)

    Door stationCamera 1 Camera 2

    LAN

    If the camera used cannot be oper-ated with 48 V DC, an additional power supply (e.g. NG 602-…) must be selected.

    The camera is connected to the ATLC via the AIVS.

    The camera is connected to the ATLC via the AIVS.

  • 13

    General Video cameras operating with the Vario door loudspeaker or exter-nally in the background provide an unobtrusive method of surveillance in the entrance area. Call, speech and door release operation of the door station. The visitor appears on screen at one or more of the video call stations.Possible applications include single and multiple family homes, private/commercial premises, practices and surgeries, administrative buildings etc.Other video components for special applications can be combined with our devices on request.

    Location of the video camera Selection of the most suitable camera and its location is decisive to ensure good picture quality. The camera must not be directed towards:

    • direct backlight• direct sunlight• very bright image backgrounds• highly reflective walls opposite the camera• lamps or direct light sources

    Pick-up range of the camera

    Diagram showing the pick-up range of external camera CE 600-… with image pick-up chip 1/3".

    If the range of a camera module is not sufficient, external cameras such as the CE 600-… or CE 950-… can be used.

    Object distance in m (h)

    Obj

    ect

    wid

    th in

    m (a

    )

    12.00

    10.00

    8.00

    6.00

    4.00

    2.00

    0.00

    3.8

    mm

    5.0

    mm

    9.5 mm

  • 14

    Diagram showing the pick-up range of external camera CE 950-… with image pick-up chip 1/4".

    Object distance in m (h)

    Obj

    ect

    wid

    th in

    m (a

    )

    3.8

    mm

    5.0 m

    m

    8.0 mm

    45.6 mm

    12.00

    10.00

    8.00

    6.00

    4.00

    2.00

    0.00

    Diagram pickup rangeCamera ACM 670-… with image pick-up chip 1/3".

    Pick-up angle of the camera module ACM 670-…The adjustment range of the ACM 670-… is indicated by shading.

    Object distance in m (h)

    Obj

    ect

    wid

    th in

    m (a

    )

    12.00

    10.00

    8.00

    6.00

    4.00

    2.00

    0.00

    AC

    M 6

    70

    2.9

    mm

    50 cm

    86 c

    m10

    6 cm

    160

    cm

    214

    cm

    appr. 60°

    113 cm

    50 c

    mappr. 80°

    3 System structure, conductor material and range Pick-up range of the camera

  • 15

    The picture excerpt visible on the display is mechanically set on the ACM 670-… camera by max. 30°.

    Diagram pickup rangeCamera ACM 673-… with image pick-up chip 1/3".

    Pick-up angle of the camera module ACM 673-…

    50 cm

    114

    cm10

    3 cm

    217

    cm

    160

    cm

    ca. 100°

    2 4 6 8 10 12

    Object distance in m (h)

    Obj

    ect

    wid

    th in

    m (a

    )

    12.00

    10.00

    8.00

    6.00

    4.00

    2.00

    0.00

    2.1

    mm

    205 cm

    50 c

    m

    appr. 130°

  • 16

    The ACM 673-… camera transmits the entire recorded video image.

    Diagram pickup rangeCamera ACM 678-… with image pick-up chip 1/3".

    Pick-up angle of the camera module ACM 678-… in full screen mode.

    ca. 135°

    160

    cm

    50 cm

    234

    cm

    43 c

    m

    277

    cm

    2 4 6 8 10 12

    12.00

    10.00

    8.00

    6.00

    4.00

    2.00

    0.00

    1.4

    mm

    Object distance in m

    Obj

    ect

    wid

    th in

    m

    appr. 165°

    760 cm

    50 c

    m

    3 System structure, conductor material and range Pick-up range of the camera

  • 17

    Select the picture excerpt based on the existing mounting situation.

    The pick-up angle of camera module ACM 678-… can be adjusted depending on the mounting situ-ation.Required picture excerpt from the camera view (1 to 9) or full screen (0).

    Picture excerpt (1–3) top camera alignmentPicture excerpt (4–6) central camera alignmentPicture excerpt (7–9) bottom camera alignment

    70° 70° 70°

    160

    cm

    160

    cm

    160

    cm

    50 cm 50 cm 50 cm

    277

    cm

    125

    cm 195

    cm

    124

    cm

    43 c

    m

    167

    cm

    70 c

    m

    124

    cm

    1 2 3

    456

    7 8 9

  • 18

    4 System components Overview

    * Can also be used for customer’s existing door stations/letterbox sys-tems.

    Door stations (outdoor/indoor area) (Possible designs: Vario/Classic/Steel)• ACM 670-…Access camera 80 for Siedle Vario

    • ACM 673-…Access camera 130 for Siedle Vario

    • ACM 678-…Access camera 180 for Siedle Vario

    • ATLE 670-… *Access custom-fit door loudspeaker incl. Bus call button matrix

    • ATLM 670-…Access door loudspeaker module

    • BRMA 050-… *Bus call button matrix

    • BTM 650-01 to -04Bus call button module

    • COM 611-…Code lock module

    • DRM 612-…Display call module

    • ELM 611-…Electronic-key reading module

    • FPM 611-…Fingerprint module

    • PME…Mail notification system(Classic/Steel)

    • TÖ 61x-…Door release (DIN left or right)

    • VTMC 640-…Flush-mounted colour camera

    External cameras/ Surface-mounted components • AIVS 670-…Access Interface analog-video standard

    • CE 600-…External colour CCD video camera for external mounting

    • CE 950-…External colour CCD video camera for external mounting

    Indoor stations (audio/video) • AHF 870-…Access handsfree telephone

    • AHFV 870-…Access video handsfree telephone

    • AHT 870-…Access in-house telephone

    • AHTV 870-…Access video in-house telephone

    • AVP 870-…Access video panel

    Upgrade (audio indoor station) • AUV 870-…Access for video upgrade

    Accessory • AZA 870-…Access surface-mount accessory

    • AZIO 870-…Access input/output accessory

    • AZTV 870-…Access table-top accessory

    • AZTVP 870-…Access table-top accessory

    • ZRE 600-…19 inch rack mounting accessory

    Distribution components • ANG 600-…Access line rectifier

    • ATLC/NG 670-…Access door loudspeaker controller with line rectifier

    • ATLCE 670-…Access door loudspeaker controller extension

    • AVA 670-…Access video decoupler

    • ECE 602-…Entrance controller extension

    • EC 602-…Entrance controller

    • NG 602-…Line rectifier

    • TCIP 603-…Door controller IP

    • TCIP SRV 603-…Door controller IP server

    • VNG 602-…Video line rectifier

    • TR 602-…Transformer

    • TR 603-…Transformer

    • ZWA 640-…Western socket accessory

  • 19

    Client-Software • ASC 170-…Access Software Concierge

    • ASHT 170-…Access Software In-house telephone

    App • Siedle app for Access

    Software integration for non-Siedle systems • ASM 170-…Access software module

    Access user licence packages (Server operation) • APR 670-0 10 Access Professional

    • APR 670-0 20 Access Professional

    • APR 670-0 40 Access Professional

    • APR 670-0 80 Access Professional

    • APR 670-0 160 Access Professional

    • APR 670-0 320 Access Professional

    Optional Access application licences (Models) • ALFA 270-…Access licence for external audio device

    • ALFS 270-…Access licence for external smart-phone

    • ALFT 270-…Access licence for external tablet

    • ALFV 270-…Access licence for external video device

    • ALKNX 270-…

  • 20

    Siedle Vario From the door bell to the switching and control centre, modern building communication has a lot to offer. Visitor information and guidance, receiving mail, lighting, security, access control and image projection: The requirements are many and varied. Siedle’s solution is a simple one: The modular principle.Siedle Vario is unmatched in its flex-ibility. As an open-ended, modular system, it fits in with the building owner’s requirements, the design specifications of the architect as well as building constraints. The Vario system design ensures that any com-bination of functional modules com-plies with the most stringent stand-ards of both form and function.Top-quality materials such as alu-minium or weather and UV-resistant polycarbonate guarantee reliable performance over a long service life.The same high standards apply to the planning and processing stage. Thanks to pre-installation, mounting aids and installation compartments, Siedle Vario is quickly and economi-cally planned and installed.

    Siedle Classic A metal range with a system:Siedle Classic provides an attractive entry into the use of premium mate-rials at the threshold. The product line is a variable system with a broad range of functions and an enlarged application spectrum. Siedle Classic provides everything you could conceivably need at the front door. Alongside intercom system with bell, access control, the letterbox and movement sensor module supple-ment the audio and video communi-cation functions.Siedle Classic is available in various standard systems. These are designed to cover the majority of door communication requirements. We are able to supply bespoke solu-tions to address special requirements in terms of design and functionality.

    Siedle Steel Door stations from the Siedle Steel range are individually produced and supplied as a fully functional com-plete unit. So when planning a new installation, all you need to decide is which type of installation system you require. We take charge of collating all the necessary components and equipping the door station.

    4 System components Door stations (outdoor/indoor area)

  • 21

    ATLM 670-0 Access door loudspeaker module in 611 Vario design.Complete module with loudspeaker, microphone and light button with LED illuminated light symbol.Up to max. 48 call button modules can be connected in any optional combination, allowing up to max. 192 users.Acoustic feedback when actuating the call button at the BTM 650-01 to -04 optional.Ambient temperature: –20 °C to +55 °CProtection system: IP 54Height of structure (mm): 9Dimensions (mm) W x H x D: 99 x 99 x 35

    The ATLM 670-0 draws 48 V DC over terminals S1-S4 from the ATLC/NG 670-0. This converts the voltage into 15 V DC with max. 400 mA and outputs this to terminals b1 and c1 of the terminal block.

    ATLE 670-0 Access custom-fit door loudspeaker with bus call button matrix for mounting in a loudspeaker compart-ment, door constructions, letter-boxes etc.12 of the client’s own call buttons can be directly connected at the bus call button matrix BRMA 050-…Control output for external camera, connection of existing buttons via BRMA 050-…Max. 16 BRMA 050-… can be con-nected to 1 ATLE 670-…Protection system: Dependent on the mounting conditionsDimensions (mm) W x H x D: ATLE 670-0 124 x 60 x 31, BRMA 050-01 53 x 100 x 17Dimensions housing (mm) W x H x D: 100 x 60 x 31

    BRMA 050-01 Bus call button matrix for the con-nection of existing call buttons to the custom-fit door loudspeaker BTLE 050-…/ATLE 670-…Max. 160 call buttons can be con-nected. However, a bus call button matrix BRMA 050-… is required for each started group of 12 call but-tons.Max. 14 BRMA 050-… can be con-nected to 1 BTLE 050-…Max. 16 BRMA 050-… can be con-nected to 1 ATLE 670-…

    The connection of the call buttons for Siedle Classic is described in the call button wiring diagram.(For detailed information, see page 104)

  • 22

    DRM 612-01 Display call module as an input device with 4-line display for placing door calls.Indication of names in the display in alphabetical order. The DRM 612-… can also be used in combination with the COM 611-… in order to display the input via the DRM 612-…Operating voltage: 12 V ACOperating current: max. 200 mAProtection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

    COM 611-02 Code lock module as an input device for the placement of door calls and control functions in conjunction with Access and the Siedle access control system.• With keypad for making calls or• For controlling in conjunction with the Easikey controller EC 602-…• C button for cancelling incorrect inputs• DR button for direct door release via the EC 602-…Operating voltage: 12 V ACOperating current: max. 140 mAProtection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

    BTM 650-01 to -04 Bus call button modules BTM 650-… with 1, 2, 3 or 4 call buttons. The BTM 650-… is connected to the ATLM 670-… via ribbon cable.Nameplate size (mm) W x H: 65 x 19.5Call button (mm) W x H: 24 x 24Protection system: IP 54Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 99 x 99 x 27

    4 System components Door stations (outdoor/indoor area)

    1 2 3

    4 5 6

    7 8 9

    F 0 COK

  • 23

    PME-… Mail notification system for signal-ling incoming post on any Access indoor station.The mail notification system must be taken into account during planning for the letterbox system, as it is no longer technically possible to retrofit it later on.To use this function, the relevant indoor station must be configured via the Access administration inter-face.

    TÖ-… (Door release) Siedle door release units are high-resistance > 20 Ohm and provide operating reliability even over long ranges.Standard commercially available door release units 8 – 12 V AC, 20 Ohm can be connected.

    AIVS 670-0 Access analog video standard inter-face in surface-mount housing for connection of an analog camera to the ATLC 670-…Following a door call, the picture from the analog camera automati-cally appears on the Access indoor call station. Manual selection of the door is also possible. The camera cannot be controlled. Protection system: IP 65Ambient temperature: –20 °C to +55 °CDimensions (mm) W x H x D: 122 x 122 x 56Dimensions housing (mm) W x H x D: 93 x 93 x 56

    AIVS 670

    Access Interface Analog-Video Standard

  • 24

    ACM 673-01 Access camera 130 for Siedle Vario with automatic day/night switchover (True Day/Night) and integrated infrared lighting. Horizontal/vertical pick-up angle: appr. 130°/100°Colour system: PALImage pick-up: CMOS sensor 1/3" 756 x 504 PixelResolution: 550 TV linesLens: 2.1 mmContinuous operation: suitable2-step heating: IntegratedProtection system: IP 54, IK 10Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 15Dimensions (mm) W x H x D: 99 x 99 x 41

    ACM 678-01 Access camera 180 for Siedle Vario with automatic day/night switchover. Horizontal/vertical pick-up angle: appr. 165°/135°Colour system: PALImage pick-up: CMOS sensor 1/3" 1280 x 960 PixelResolution: 600 TV linesLens: 1.4 mmContinuous operation: suitable2-step heating: IntegratedProtection system: IP 54, IK 10Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 15Dimensions (mm) W x H x D: 99 x 99 x 41

    4 System components Access cameras

    ACM 670-02 Access camera 80 for Siedle Vario with automatic day/night switchover (True Day/Night) and integrated infrared lighting. Horizontal/vertical pick-up angle: appr. 80°/60°Colour system: PALImage pick-up: CMOS sensor 1/3" 728 x 488 PixelResolution: 500 TV linesLens: 2.9 mmMechanical adjustment range: 30° horizontal/vertical2-step heating: IntegratedProtection system: IP 54, IK 10Ambient temperature: –20 °C to +55 °CHeight of structure (mm): 32Dimensions (mm) W x H x D: 99 x 99 x 58

  • 25

    VTMC 640-01 Flush-mounted colour camera with automatic day/night switchover and integrated infrared lighting. Horizontal/vertical pick-up angle: appr. 65°/53°Colour system: PALImage pick-up: CCD sensor 1/3" 752 x 582 PixelResolution: 470 TV linesLens: 3.7 mmContinuous operation: suitableHeating: 12 V AC max. 50 mAVideo output: 1 Vss at 75 OhmOperating voltage: 20–30 V DCOperating current: max. 105 mAProtection system: IP 54Ambient temperature: –20 °C to +40 °CDimensions (mm) W x H x D: 99 x 99 x 26

    This analogue camera is connected to the ATLC 670-… door con-troller via the Access AIVSE 670-… analogue-video standard interface mounting.An additional power supply is required for the camera heating (e.g. TR 603-…).

    CE 950-01 Colour CCD video camera external mounting with automatic day/night switchover (True Day/Night) and inte-grated infrared lighting. Horizontal pick-up angle: ca. 45,6°–4,0°Colour system: PALImage pick-up: CCD sensor 1/4" 976 x 582 PixelResolution: 700 TV linesLens: 3.8–45.6 mmMechanical adjustment range: 180° horizontal/verticalContinuous operation: suitableVideo output: 1 Vss at 75 OhmOperating voltage: 20–50 V DCOperating current: max. 500 mAProtection system: IP 67Ambient temperature: –20 °C to +50 °CDimensions (mm) W x H x D: 100 x 108 x 267

    CE 600-01 Colour CCD video camera external mounting with automatic day/night switchover (True Day/Night) and inte-grated infrared lighting. Horizontal pick-up angle: appr. 81.2°–22.5°Colour system: PALImage pick-up: CCD sensor 1/3" 976 x 582 PixelResolution: 750 TV linesLens: 2.8–12 mmMechanical adjustment range: 160° horizontal/180° verticalContinuous operation: suitableVideo output: 1 Vss at 75 OhmOperating voltage: 20–50 V DCOperating current: max. 250 mAProtection system: IP 67Ambient temperature: –20 °C to +50 °CDimensions (mm) W x H x D: 75.3 x 76 x 218.5

    External cameras

  • 26

    AVP 870-0 Access video panel with touchscreen 17.8 cm for the Access system, made of high-grade plastic. The panel is a system product with a low-profile surface-mount housing for wall and table-top mounting. It provides ergonomically designed intuitive user prompting with gesture control.

    The AVP 870-… can only be used in conjunction with Server Release V.2.1.0 and higher.On a change of release, additional costs could be incurred under certain circumstances.

    With the functions calling, speech, vision, door release, light, remote switching and call silencing.Performance features:• Individual crafted design concept offering a wide choice of varied fea-tures and finishes• Display offers graphic scope for individual operation • 17.8 cm (7") touchscreen, resolu-tion 800 x 480 Pixel• Brilliant image reproduction• Excellent audio quality (dual loud-speaker technology)• Input for storey call• Output freely programmable• Additional inputs and outputs with Access input/output accessory AZIO 870-…• Call differentiation between door calls, storey calls, and internal calls• Switching functions• Video memory function• Can be used with table-top acces-sory AZTVP 870-… as a table-top device• Update capability using the Access server

    Current consumption of the indoor station: PoE class 3Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 202 x 202 x 30

    AHTV 870-0 Access in-house telephone video with door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the camera image and the graphic menu interface.With the functions calling, speech, door release, vision, light, remote switching and call silencing.Performance features:• Display 8.8 cm• Entrance for storey calls• Exit freely programmable• Call differentiation between door calls, storey calls and indoor calls• Switching functions• Status indications• Video memory function• Integrated 5-way control button• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 51

    4 System components Indoor stations (audio/video)

  • 27

    AHT 870-0 Access in-house telephone with door release button and 7 additional but-tons with 2-colour status LED. All buttons are freely programmable. The display shows the graphic menu interface, but not a camera image. It is possible to upgrade to a fully functional video station.With the functions calling, speech, door release, light, remote switching and call barring.With the additional purchase of the AUV 870-… T, the AHT 870-… can be transformed into a fully valid video indoor device.Performance features:• Display 8.8 cm• Input for storey call• Output freely programmable• Call differentiation between door calls, storey calls, and internal calls• Switching functions• Status messages• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 51

    AHFV 870-0 Access handsfree telephone video with speech/control button, door release button and 7 additional but-tons with 2-colour status LED. All buttons are freely programmable. The display shows the camera image and the graphic menu interface.With the functions calling, speech, door release, vision, light, remote switching and call silencing. Performance features:• Display 8.8 cm• Entrance for storey calls• Exit freely programmable• Call differentiation between door calls, storey calls and indoor calls• Switching functions• Status indications• Video memory function• Integrated 5-way control button• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 32

    AHF 870-0 Access handsfree telephone with speech/control button, door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the graphic menu interface, but not a camera image. It is pos-sible to upgrade to a fully functional video station.With the functions calling, speech, door release, light, remote switching and call barring.With the additional purchase of the AUV 870-… F, the AHF 870-… can be transformed into a fully valid video indoor device.Performance features:• Display 8.8 cm• Input for storey call• Output freely programmable• Call differentiation between door calls, storey calls, and internal calls• Switching functions• Status messages• Can be used with table-top acces-sory AZTV 870-… as a table-top deviceCurrent consumption of the indoor station: PoE class 2Operating voltage: PoE in accord-ance with 802.3afAmbient temperature: +5 °C to +40 °CDimensions (mm) W x H x D: 106 x 278 x 32

  • 28

    AUV 870-0 T/F Access upgrade video subsequently enables the video function in an audio device.For the in-house telephone AHT 870-…, the AUV 870-0 T is required / for the handsfree telephone AHF 870-…, the AUV 870-0 F.

    4 System components Accessory

    AZTV 870-0 Access table-top accessory for Access in-house and handsfree telephones for conversion from wall mounted to table-top device, slip-proof console.Connecting cable: 2 x 8-core 3 m long with RJ45 plug

    AZA 870-0 Access surface-mounting accessory for professional surface mounting of Access in-house and handsfree telephones.Comprises a connection adapter and 4 spacers. The raised height is increased by 8 mm.

    AZIO 870-0 Access input/output accessory as circuit board for integration in an indoor unit with an additional input/output.Switching output:n.o. contact 30 V AC/DC, 1 ASwitching input for potential-free contacts (min. 20 V DC, 10 mA)

    AZTVP 870-0 Table-top accessory for the video panel AVP 870-… for conversion from a wall to a table unit.Performance features:• Individual design concept with 3 design variants• Slip-proof table foot• Cable guide• 2 connecting cables with RJ45 plugConnecting cable: 2 x 8-core 3 m long with RJ45 plug

    ZRE 600-0 19 inch rack mounting accessory for the Access Server S and the TCIP server. Comprising retaining plate including mounted handles and mounting accessories.Dimensions (mm) W x H x D: 483 x 88 x 132

    TopOben

  • 29

    ATLC/NG 670-0 Access door loudspeaker controller with line rectifier in switch panel housing as an interface for the con-nection and power supply of door components to the Access network.

    Set consisting of ATLC 670-0 and ANG 600-0.

    ATLC 670-0 Access door loudspeaker controller in switch panel housing as interface for connecting the door station to a network.Switch contact for door release and freely programmable switching input.Optional connection facility for a maximum of 3 extension modules ATLCE 670-…Supply via ANG 600-0Supply voltage 48 V DCOutput voltage: 10–16 VOutput current: max. 700/300 mA AC/DCContact type: Contact 30 V, 2 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

    Distribution components – Door controller

    ANG 600-0 Access line rectifier in switch panel housing for power supply e.g. to the ATLC 670-… with 230 V AC switching contact.Admissible switching output:• Light bulbs max. 1300 W• Fluorescent lamps max. 800 W• Twin fluorescent lamps max. 1200 W• Parallel compensated fluorescent lamps max. 400 WOperating voltage: 100–240 V AC, +/-10 %, 50/60 HzOperating current: 0.5–1 AOutput voltage: 48 V DCOutput current: 800 mAFusing: primary T 2 A, secondary short circuit proofContact type: changeover switch max. 250 V AC, 6 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

  • 30

    ATLCE 670-0 Access door loudspeaker controller extension in switch panel housing with 4 outputs and 2 inputs.A maximum of 3 ATLCE 670-… units can be connected in series to an ATLC 670-… by means of ribbon cable.Protection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

    AVA 670-0 Access video decoupler in switch panel housing. Permits the decou-pling of an analogue video signal from the Access system.Operating voltage: 10–50 V DCOperating current: max. 25 mAProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

    ZWA 640-0 Western socket accessory for switch panel mounting. Integrated socket for 4/6/8-pin western plug.Connection by means of screw-type terminals.Protection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 1Dimensions (mm) W x H x D: 18 x 90 x 60

    4 System components Distribution components – Active/passive system expansion

    DSC 602-0 Pilfer safeguard controller in a switch panel housing to control a maximum of 2 pilfer safeguard accessories ZDS 601-…Using 2 integrated buttons, the mounting frame can be locked and unlocked. An LED flashes to indi-cate that the release button at the DSC 602-… has been activated. It is only possible to lock the mounting frame after removing the Vario key.Operating voltage: 12 V ACOperating current: max. 100 mAProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

  • 31

    VNG 602-02 Video line rectifier in switch panel housing for centrally supplying video door intercom systems or for sup-plying additional components (e.g. external camera).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 200 mAOutput voltage: 30 V DCOutput current: 1.1 AFusing: Si 1 T 200 mA, secondary side thermal fuseProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 10Dimensions (mm) W x H x D: 180 x 89 x 60

    NG 602-01 Line rectifier in switch panel housing for supplying additional components (e.g. external camera).Operating voltage: 230 V AC, +/-10 %, 50/60 HzTypical current consumption: 41 VAOutput voltage: 23.3 V DC, 12 V ACOutput current: 0.3 A DC, 1.6 A ACProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

    Distribution components – Line rectifiers

    ANG 600-0 Access line rectifier in switch panel housing for power supply e.g. to the ATLC 670-… with 230 V AC switching contact.Admissible switching output:• Light bulbs max. 1300 W• Fluorescent lamps max. 800 W• Twin fluorescent lamps max. 1200 W• Parallel compensated fluorescent lamps max. 400 WOperating voltage: 100–240 V AC, +/-10 %, 50/60 HzOperating current: 0.5–1 AOutput voltage: 48 V DCOutput current: 800 mAFusing: primary T 2 A, secondary short circuit proofContact type: changeover switch max. 250 V AC, 6 AProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

  • 32

    TR 602-01Transformer in switch panel housing for supplying additional components (e.g. easikey controller for access control).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 170 mAOutput voltage: 12 V ACOutput current: max. 2.5 AFusing: Secondary side with thermal fuseProtection system: IP 20Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 6Dimensions (mm) W x H x D: 107 x 89 x 60

    TR 603-0Transformer in switch panel housing for supplying additional components (e.g. mail notification system or door release via potential-free contact).Operating voltage: 230 V AC, +/-10 %, 50/60 HzOperating current: 100 mAOutput voltage: 12 V ACOutput current: max. 1.3 AFusing: Secondary side with thermal fuseProtection system: IP 30Ambient temperature: 0 °C to +40 °CHorizontal pitch (HP): 3Dimensions (mm) W x H x D: 53.5 x 89 x 60

    4 System components Distribution components – Transformers

  • 33

    Space requirements in distribution boards/IT cabinets (19 inch)

    Space required (height) in IT cabinet system/housing (19 inch)

    Models Rack units (RU)

    AGW 670-0 2

    ASH 670-04 M 2

    ASH 670-04 S * (2)

    TCIP SRV 603-0* (2)

    * with rack installation kit: ZRE 600-0 2

    Please make sufficient provisions in the electrical distribution boards/IT cabinet system for later expansion, changes or subsequent disassembly (service/maintenance).All system components which are designed for/suitable for installation in an electrical distribution board or in an IT cabinet system/housing may only be installed in the permitted installation position according to the enclosed product information. If system components are operated in improper installation positions or with improper operating parameters (e.g. excessive ambient tempera-ture), this will render their warranty rights void in the event of service.During planning, take the applicable legal provisions, standards, directives and safety instructions for the opera-tion/installation site into account.

    Space requirement in the distributor

    Models Horizontal pitches (TE)

    ANG 600-0 6

    ASH 670-04 S * 3 x 12 TE

    ATLC 670-0 6

    ATLCE 670-0 3

    ATLC/NG 670-0 2 x 6 TE

    AVA 670-0 3

    EC 602-03 6

    ECE 602-0 3

    NG 602-01 6

    TCIP SRV 603-0 * 3 x 12 TE

    TCIP 603-03 8

    TR 602-01 6

    TR 603-0 3

    VNG 602-02 10

    * with top hat rail mounting kit.Please ensure enough space is provided for service and maintenance.

  • 34

    ASH 670-04 S Access Server hardware S for the IP-based building communication system Siedle Access Professional for up to 50 users. An Access user licence is required for the regular use of Access Server hardware.Version in a metal housing suitable for top hat rail mounting (space requirement distribution: 3 x 12 horizontal pitch units (TE)). Capable of integration in the existing IT landscape (with optional acces-sory ZRE 600-0 rack installation kit (486.6mm/19") – space requirement (height): 2 rack units (HE)). Scope of supply: Access Server hardware in desktop housing incl. pre-installed server operating system Windows Server 2012 R2 for Telecommunication and Access Professional with 30-day test licence as well as electrical con-necting cable and small mounting items for top hat rail mounting.Components:CPU: Intel Atom D510; 1.6 GHz Dual-CoreWorking memory: 2 GB DDR3Graphic: Intel GMA3150Hard disc: 320 GB SATA-IILAN: 2 x gigabitOperating voltage: 90–264 V AC, 47–63 HzTypical current consumption: max. 45 WHorizontal pitch (HP): 3 x 12Ambient temperature: +10 °C to +50 °CDimensions (mm) W x H x D: 328 x 88.8 x 201

    ASH 670-04 M Access Server hardware M for the IP-based building communication system Siedle Access Professional for up to 320 users. An Access user licence is required for the regular use of Access Server hardware.Version in a housing for IT cabinet systems (482.6 mm / 19") – space requirement (height): 2 rack units (HE).Scope of supply: Access Server hardware in 19" housing incl. pre-installed server operating system Windows Server 2012 R2 for Telecommunication and Access Professional with 30-day test licence as well as electrical con-necting cable and small mounting items for installation in an existing 19" IT cabinet system.Components:CPU: Intel Xeon X3430; 2.4 GHz Quad-CoreWorking memory: 4 GB DDR3Graphics: Matrox G200eWHard disc: 250 GB SATA-IILAN: 2 x gigabitOperating voltage: 90–264 V AC, 47–63 HzTypical current consumption: max. 78 WAmbient temperature: +10 °C to +35 °CDimensions (mm) W x H x D: 463 x 88 x 460

    4 System components Access server variants

    Access Professional Access system software for installa-tion and operation on existing server hardware/virtualization with installed server operating system according to requirements. For regular operation of the Access system, an Access user licence for up to 320 users/devices must be purchased for a fee. The trial period for an Access system without a valid Access user licence ends after 30 days. In order to operate Access Professional correctly as a software variant, the provided server hardware/virtual machine and the network infrastructure must meet the minimum requirements of the Access system:• Processor output: min. Intel Xeon Quad Core Processor 64 Bit (from launch year 2014 or more recent)• Random access memory (RAM): at least 4 GB• Storage location (HD): at least 256 GB• Network connection (LAN): at least 1 x 1000 Mbit/s• Recommended number of line rectifiers: 2• Operating system: Microsoft Server 2012 R2 Standard or Datacenter (installation: Standard full installation -> Server with graphic user interface)• Role of the server operating system: optionally: DHCP server ser-vice, if no DHCP server is operated in the existing network.• Necessary DHCP options: Time Server, Log Servers, NTP Servers, Boot Server Host Name, Bootfile NameOptionally: Router (Default Gateway), Domain Name and DNS-Server

  • 35

    A comparison of Access server variants

    Access server variant Access Professional ASH 670-04 M ASH 670-04 S

    Finish Software without server oper-ating system/virtualization

    Hardware server + pre-installed Access Professional

    Hardware server + pre-installed Access Professional

    Access system version Access Professional V 4… Access Professional V 4… Access Professional V 4…

    Possible number of users (User licences)

    10–320 10–320 10–50

    Possible number of com-munication connections (simultaneously)

    25 25 10

    Conditions • Hardware server• Server operating system (MS Server 2012 R2 Standard)• Microsoft .NET Framework 4.6.1 for Windows Server 2012 R2 (offline installer or web installer if internet connection exists).• Network/VLAN as required• Indoor stations with POE supply • Software clients/apps on terminals with network con-nection

    • Network/VLAN as required• Indoor stations with POE supply • Software clients/apps on terminals with network connection

    • Network/VLAN as required• Indoor stations with POE supply • Software clients/apps on terminals with network connection

    As-delivered status • The Access server must be installed and commissioned.• For regular operation of the Access system, an Access user licence for up to 320 users/devices must be purchased for a fee. The trial period for an Access system without a valid Access user licence ends after 30 days.• The server hardware/virtu-alization and server operating system must be provided by the customer and must be available.• Microsoft licences: Please check whether any Microsoft server access licences (Client Access License – CAL) are required by the customer for operation of the Access users, or whether these already exist. (For detailed informa-tion, see page 43)

    • The Access server is installed ready for operation and prepared for commissioning by the customer.• An Access user licence is required for the regular use of Access Professional. The Access user licence allows Siedle Access Professional to be enabled and used in Version V 4.0.0 for up to 320 users/terminals per system (optionally inclusive of licensed hardware indoor stations/door stations and/or optional hardware and software terminals to be licensed). Access user licences can be purchased for 10, 20, 40, 80, 160 or 320 users/terminals and combined as required. The trial period for an Access system without a valid Access user licence ends after 30 days.• Optional application licences enable the use of addi-tional performance features.

    RemarkThe standard password for the server operating system of a Access Server Hardware (from ASH 670-04…) is: SiedleAccessMain2015

    Please change the password on initial commis-sioning, taking note of the security instructions.

    Maintenance contract Maintenance contracts for the Siedle Access system can be purchased both through the Siedle Project Sales and through an Access Certified Partner (ACP).(For detailed information, see page 133)

  • 36

    Minimum requirements – Server hardware / Virtual machine *

    Possible number of users (User licences)

    320 50

    Processor output min. Intel Xeon Quad Core Processor 64 Bit (from launch year 2014 or more recent)

    min. Intel Atom D510; 1.6 GHz dual-core *

    Random access memory (RAM) at least 4 GB at least 2 GB

    Storage location (HD) at least 256 GB

    Network connection (LAN) at least 1 x 1000 Mbit/s

    Server operating system/software

    Operating system Microsoft Server 2012 R2 Standard or Datacenter (installation: Standard full installation -> Server with graphic user interface)

    Role of the server operating system optionally: DHCP server service, if no DHCP server is operated in the existing network.

    Other server services optionally: NTP server

    Necessary DHCP options Time Server, Log Servers, NTP Servers, Boot Server Host Name, Bootfile NameOptionally: Router (Default Gateway), Domain Name and DNS-Server

    Access system version Access Professional – from Version 4.0.0

    Access licences For regular operation of Access Professional, an Access user licence must be purchased against a fee.Optional application licences enable the use of additional performance features.

    Network connection

    Network Own physical network from CAT-5 and optionally with modified VLAN with Quality of Service (IEEE802.1p)

    Transmission speed 100 MBit/sec (End devices)1000 MBit/sec (Server hardware)

    Internet protocol IPv4

    Multicast capability(only if you wish the video signal to be transferred in the network as a multicast stream. As an alterna-tive, the unicast operation mode can be used. With unicast, every video stream is separately generated and can cause very high network capacity utilization where there are high number of users with approx. 1 MBit per user.)

    Throughout the entire network

    Distribution list The use of switches is a requirement.

    Power over Ethernet (PoE) Access indoor stations require PoE-capable switches or PoE injectors in compliance with IEEE802.3af

    4 System components A comparison of Access server variants

  • 37

    System conditions Access Professional In order to operate Access Professional correctly as a soft-ware variant, the provided server hardware/virtual machine and the network infrastructure must meet the minimum requirements of the Access system

    Remarks• In order to work with Access Server Administration, you need an PC with the latest version of the web browser Mozilla Firefox.If you use a different web browser to the Mozilla Firefox, display errors can occur.• Two network sockets are affixed to the back of the Access server hardware (Service and Access). For linking the Access devices to the Access network, the Access socket must be used.

    Notice on the scope of supply The Access server hardware is delivered as standard with the fol-lowing additional software tools and releases:• 7-Zip (x64)• Firefox• Notepad++• Putty• Wireshark• WinPcap• Remote desktop release

    The listed files and programs are required for configuration and servicing purposes and should only be used by specialist and servicing personnel.The Access system (software variant) is delivered without these additional software tools and releases.

    Additional requirements imposed on virtualization • For virtualization, from VMware  vSphere 6 upwards a virtualization solution configured for server sys-tems must be used.• The minimum requirements imposed on the virtual machine are the same on principle as server hardware provided by the customer for up to 320 users. With the virtual machine, remember that at least 2 virtual and separate processor units (CPUs) must be made available.• If virtualization is used, the host (physically present server on which the virtual machine is operated) must have sufficient performance to make available the output needed for the virtual machine.

    RemarksThe size of the hard disk storage capacity which should be selected depends on various factors when using a virtualization solution:• Number of users, groups and terminals• Utilization scenario and incidence of communication• Activated video memory func-tion: If no video memory function is used, we recommend a hard disk storage capacity of at least 30 Gigabytes. When using the video memory function, please contact the Access Service Center to be advised on the minimum capacity required for the hard disk memory.• For Access systems with up to 50 users, server hardware can be used which corresponds to the performance data of Access server hardware S:• - Processor output: At least Intel Atom D510; 1.6 GHz dual-core• - Random access memory (RAM): at least 2 GB• Important: Please note that in this configuration, no virtualization and no additional system expansion are possible.

    * For Access systems with up to 50 users, server hardware can be used which corresponds to the performance data of Access server hardware S:- Processor output: At least Intel Atom D510; 1.6 GHz dual-core- Random access memory (RAM): at least 2 GBImportant: Please note that in this configuration, no virtualization and no additional system expansion are possible.

    Virtualization

  • 38

    4 System components Network security

    AGW 670-01 Access gateway for the physical sep-aration of 2 networks (e.g. customer network and Access network) at an Access server. To operate Access terminals in different networks, using one or more Access gateways in large network structures allows two or more proprietary networks to be linked to an Access system while ensuring that they remain strictly separate.The AGW 670-… can only be used in conjunction with Server Release V.2.1.3 Build 938 and higher.On a change of release, additional costs could be incurred under certain circumstances.Operating voltage: 12 V DCTypical current consumption: max. 24 WAmbient temperature: 0 °C to +50 °CDimensions (mm) W x H x D: 200 x 200 x 52

    ASHT 170-0 Access application licence “Access Software In-house telephone” for the operation of ASHT software on the Access system. The ASHT enables audio and video door communication via Windows-based PCs or control panels.Function overview:• Call differentiation between door calls, storey calls and indoor calls• Device and user overview • Users, doors and devices can be selected from lists• Global contact list• Status displays of switchgear • Switching functions via ATLC/ATLCE or KNXSystem requirements:• Microsoft® Windows 7, 8, 8.1, 10• Microsoft® .NET Framework 4.6.1• Microsoft® VC++ 2013 Redistributable Package (x86)• Microsoft® VC++ 2015 Redistributable Package (x86)• At least Microsoft® DirectX® 9.0c• CPU: Dual-Core from 2.0 GHz• At least 2 GB RAM• Graphics card with at least 1280 x 720 pixel, 128 MB RAM• Ethernet card/Network connection: 100 Mbit• Sound card

    Client-Software

    ASC 170-0 Access application licence “Access Software Concierge” for the opera-tion of the ASC software on the Access system.The ASC is the central communica-tion interface at the reception.Function overview:• Several audio and video links can be depicted simultaneously• Convenient forwarding functions • Music-on-hold• Status overview of all Doormatic door statuses• Convenient switching/control and display functions• Global contact list (incl. personal contact management)• Camera scan function • Answering machine functionsSystem requirements:• Microsoft® Windows 7, 8, 8.1, 10• Microsoft® .NET Framework 4.6.1• Microsoft® VC++ 2013 Redistributable Package (x86)• Microsoft® VC++ 2015 Redistributable Package (x86)• At least Microsoft® DirectX® 9.0c• CPU: Dual-Core from 2.0 GHz• At least 2 GB RAM• Graphics card with at least 1280 x 720 pixel, 128 MB RAM• Ethernet card/Network connection: 100 Mbit• Sound card

    www.siedle.de/access www.siedle.de/access

  • 39

    Upgrade (server)

    ASM 170-0 Access application licence “Access software module” for the opera-tion of ASM software on the Access system.The ASM enables Siedle Access to be integrated into non-Siedle systems (e.g. touch panels).You will be kept up to date with the latest information by our Project Sales DepartmentSystem requirements:• Microsoft® Windows 7, 8, 8.1, 10• Microsoft® .NET Framework 4.6.1• Microsoft® VC++ 2013 Redistributable Package (x86)• Microsoft® VC++ 2015 Redistributable Package (x86)• At least Microsoft® DirectX® 9.0c• CPU: Dual-Core from 2.0 GHz• At least 2 GB RAM• Graphics card with at least 128 MB RAM• Ethernet card/Network connection: 100 Mbit• Sound card

    Software integration for non-Siedle systems

    Siedle app for Access The Siedle app for Access turns the iPhone or iPad into a mobile exten-sion of an Access door intercom from Siedle: It allows you to see who is standing outside your door, talk to visitors at the entrance and open the door if you choose – no matter where you happen to be. The con-nection is established via WLAN or via the mobile phone network.If the app is not activated or if the bandwidth of the data network is not sufficient, the Access server automatically establishes a speech connection via the telephone net-work (call function). The call func-tion is only available for the iPhone.The Siedle app for Access can also perform switching and control func-tions, for example door release, light, garage door or shutters. Switching and control functions are encrypted for security purposes.

    The complete functional scope of the Siedle app is described in the Apple App Store.

    App

    ASU 670-04 Access Server upgrade package for upgrading existing Access Server hardware with Access server software V. 1.x.x or V 2.x.x to Access Professional V 4.0.0.The Access server upgrade package can be purchased exclusively through an Access Certified Partner. To place the order, the serial number of the server hardware and the hardware ID of the existing access system are required. The upgrade may only be performed by an Access Certified Partner (ACP) or by the Access Service Center (ASC).Existing licences for the previous Access system remain valid, but must be converted.Scope of supply:• USB stick with system image (Microsoft Windows Server 2012 R2 for Telecommunication and Access Professional with 30-day test licence)• Microsoft End User Licence Agreement (EULA)• Windows Certificate of Authenticity (COA)• Upgrade instructions

    www.siedle.de/accesswww.siedle.de/access

  • 40

    4 System components Access licences

    Licence management/Licence purchasing For regular operation of the Access system, an Access user licence for up to 320 users/devices must be pur-chased for a fee. Optional application licences enable the use of additional performance features.

    Do you need Access licences?• Customers and sales partners from Germany, please consult one of our Siedle centres or one of our Access Certified Partners. * Also in your area.• Qualified staff are on hand to offer a fast, competent service.• By telephone, or where neces-sary we will be pleased to visit you on site.• Customers outside of Germany can contact one of our international representatives.(For detailed information, see page 152)

    * Access Certified Partners (ACPs) are authorized to commission Access systems. They have proven their competency as planners and admin-istrators of Siedle Access systems, have passed independent audits per-formed by the accredited body TÜV Süd and are certified by Siedle.Contact details are available on the internet at www.siedle.com/acp

    Notices – third party device licences For many requirements, the market is flooded by a large number of ideas and devices. Communication and compatibility between the dif-ferent components can sometimes be an issue. For this reason, it is advisable to make contact at an early stage with our project sales depart-ment. The link-up of new third-party devices / technical systems can be checked on customer request. For testing, a test device must be made available by the customer.

    Procedure – Licence order

    Access Professional(Software variant)

    ASH 670-04 M/S(Access server hardware)

    Test licencesThe trial period for an Access system without a valid Access user licence ends after 30 days.For regular operation of Access Professional, an Access user licence must be purchased against a fee.After expiry of the 30-day test period, the Access system is deacti-vated and cannot be used until the Access user licence is imported.Optional application licences enable the use of additional performance features.

    Test licencesThe trial period for an Access system without a valid Access user licence ends after 30 days.For regular operation of Access Professional, an Access user licence must be purchased against a fee.After expiry of the 30-day test period, the Access system is deacti-vated and cannot be used until the Access user licence is imported.Optional application licences enable the use of additional performance features.

    Time of placement of orderThe Access user licence and optional application licences must be ordered from an Access Certified Partner after Access Professional has been started for initial commissioning and the hardware ID has been gener-ated. For licence orders, the hard-ware ID generated by the Access system is required.

    Time of placement of orderThe Access user licence and optional application licences must be ordered from an Access Certified Partner after Access Professional has been started for initial commissioning and the hardware ID has been gener-ated. For licence orders, the hard-ware ID generated by the Access system is required.

    Microsoft licencesPlease check whether any Microsoft server access licences (Client Access License – CAL) are required by the customer for operation of the Access users, or whether these already exist. Microsoft Client Licences (CAL) are not included in the scope of supply of the Access server.

    Microsoft licencesNo additional Microsoft server access licences (Client Access License – CAL) required.

  • 41

    Access user licence packages – Server operation (All Access server variants)

    Licence package – APR 670-0 [xx] Description

    APR 670-0 10APR 670-0 20APR 670-0 40APR 670-0 80APR 670-0 160APR 670-0 320

    An Access user licence is required for the regular use of Access Professional. The Access user licence allows Siedle Access Professional to be enabled and used in Version V 4.0.0 for up to 320 users/terminals per system (optionally inclusive of licensed hardware indoor stations/door stations and/or optional hardware and software terminals to be licensed). Access user licences can be purchased for 10, 20, 40, 80, 160 or 320 users/terminals and combined as required. The trial period for an Access system without a valid Access user licence ends after 30 days. Existing licences for the previous Access system remain valid, but must be converted.

  • 42

    Optional Access application licences (All Access server variants) Optional application licences enable the use of additional performance features. These are sold exclusively through our Access Certified Partners, who will then also enable the licences for you.

    Licence type Description

    Third-party audio device (ALFA 270-0)

    Access licence for third-party audio device, for link-up of a VoIP audio tele-phone to the Access system. An analogue telephone can be connected via a VoIP-ATA adapter. Third-party devices are subject to authorization by Siedle.

    Non-Siedle smartphone device (ALFS 270-0)

    The third-party smartphone Access licence permits connection of the smart-phone to the Access server. A separate licence is required per device. The smartphone functions as a mobile indoor device with video. An additional app is required for operation. This must be purchased from the App Store. (Currently only iPhones and not Android or Windows smartphones).

    Non-Siedle tablet device (ALFT 270-0)

    The Access licence for third-party tablets permits connection of the tablet to the Access server. A separate licence is required per device. The tablet functions as a mobile indoor device with video. An additional app is required for operation. This must be purchased from the App Store. (Currently only iPhones or iPads and not Android or Windows tablets).

    Non-Siedle video device (ALFV 270-0)

    Access licence for third-party video device, for link-up of a VoIP video tel-ephone to the Access system. A separate licence is required per device. Third-party devices are subject to authorization by Siedle.

    KNX link (ALKNX 270-0

  • 43

    Microsoft licences (CAL)

    Microsoft Client Licences (CAL) are not included in the scope of supply of the Access server.

    The Microsoft Client Access License (CAL) licences access by devices or users to Microsoft server operating systems whose licence model envis-ages that additional licensing is required every time the server soft-ware is accessed.

    Customers who wish to operate the Access system on their own server must check whether CALS have to be purchased or whether the existing provision (in respect of the server type and CAL variant) is sufficient (e.g. the customer already has user CALs for all employees for the Windows server 2012. The cus-tomer is required to check its own licence agreements to determine whether these entitle users to access the Windows server of the Access system.).

    CAL variants• Device CAL: A device CAL entitles all users to use a certain device with server access (e.g. PC in the workshop which is used by different employees.).• User CAL: A user CAL entitles a certain user to use any optional number of devices with server access (e.g. employee uses a PC, laptop and smartphone).

  • 44

    5 Function overview

    Calling, speech and video functions between door station and the con-nected Access indoor stations.An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The defini-tion of functions and the relevant buttons take place during configura-tion of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server.

    Connection facility for a storey call button (ERT) for calling an apart-ment door and potential-free con-tact is available as standard.Different ringtones for calling from the front door, the apartment door, concierge or internal call.

    Supplementary functions • Internal calls and speech commu-nication between Access indoor call stations are possible.• Connection of an analogue camera to the ATLC 670-… via the interface AIVS 670-…• Concierge function as central interface, e.g. at the reception• 8 freely selectable ringtones• Call forwarding• Call follow-me function• Parallel door and storey call• Group formation possible• Selective dialling of the door sta-tion using additional free buttons• Central video memory module (server) possible

    Access system function Access system version

    Communication V 4.0.x

    Internal calls/internal conversations •

    Audio and video privacy device •

    Door call and door conversation with video •

    Direct door call with video •

    Storey call •

    Echo compensation •

    Active background noise suppression •

    Call list with history (ASC/ASHT) •

    Send and receive text messages (ASC/ASHT) •

    Voicebox (ASC/ASHT) •

    Storey call to groups configurable •

    Acoustic feedback after pressing a call button •

    AZIO configurable (additional input and output for AHT/AHTV, AHF/AHFV, AVP) •

    Support of the ZAM 670 (Status display module) •

    CTI-Call support with ASC/ASHT and external IP telephone •

    • = available- = Not available

  • 45

    Access system function Access system version

    Video functions V 4.0.x

    Central image memory •

    Automatic and selective capture of a camera image per door call •

    Selective capture, display and deletion of camera images/pictures •

    Camera dialling via contact list or in video area •

    Camera scan mode (ASC) •

    Telephony functions

    Connection of a telecommunications system to the Access Server (only VoIP) •

    Selection of public network numbers •

    Call using the landline network using a code lock •

    Hold (ASC/ASHT) •

    Brokering (ASC) •

    Music on hold •

    Call rerouting •

    Call forwarding (ASC) •

    Display of participant status •

    Individual language setting (AHT/AHTV, AHF/AHFV, AVP) •

    Supports DTMF tones (SIP info) for telephony connection •

    Supports DTMF tones (RCF2833) for telephony connection •

    Control functions (switching/control)

    Doormatic function (target-, doorbased) with status indicator •

    Support for binary KNX functions •

    Switching functions configurable to call buttons •

    ATLC input configurable •

    Support for the ATLCE •

    Inverting an output •

    Retriggering an output •

    Support for the mail notification system •

  • 46

    5 Function overview

    Access system function Access system version

    Commissioning functions V 4.0.x

    Browser-based commissioning •

    Central management and configuration of participants and devices •

    Group administration •

    Several administrators with different authorisation levels •

    Extended DHCP setting possibilities (from V 3.0.0 in the server operating system)

    -

    DHCP IP address range can be set •

    NTP server can be set •

    Remote configuration via the Access server's web interface •

    Service functions

    Configuration backup •

    Remote maintenance and updates(Internet connection required!)

    Monitoring of system capacity utilization (via dashboard) •

    Manual line / user monitoring •

    Management of software statuses in the Access server •

    Detailed logging for Siedle support •

    Interfaces

    Connection to standardised IP telephone systems •

    Integration of a / b converters •

    External analogue cameras (with Access Interface Analog Video Standard – AIVS 670… to ATLC)

    KNX or other building automation systems (e.g. Crestron or Control4) •

    Link to video recording devices, operating displays and video servers via the den Access video decoupler

    Compilation of customer-specific scripts for the automation of functions (optional and subject to charge)

    Access control (via Vario bus) •

  • 47

    Access system function Access system version

    Client-Software V 4.0.x

    ASHT: Overlay entire application on an incoming call •

    ASHT: Automatic login and minimizing on Windows start-up •

    ASC/ASHT: Confirmation request prior to closing the application •

    ASM: Software module (integration in non-Siedle systems) •

    App

    Siedle app for Access (iPhone) •

    Siedle app for Access (iPad) •

    Hardware clients

    AVP •

    AVP with KNX •

    AHF/AHFV •

    AHT/AHTV •

    Non-Siedle devices (SIP) •

    • = available- = Not available

  • 48

    * from Access-Server V 3.1… • = available- = Not available

    6 Configuration – Access System Models

    ATL

    C 6

    70-…

    AH

    F 87

    0-…

    AH

    FV 8

    70-…

    AH

    T 87

    0-…

    AH

    TV 8

    70-…

    AV

    P 87

    0-…

    ASC

     170

    -…

    ASH

    T 17

    0-…

    ASM

     170

    -…

    Sied

    le A

    pp iP

    ad

    Sied

    le a

    pp iP

    hone

    SIP

    vide

    o te

    leph

    one

    SIP

    audi

    o te

    leph

    one

    Exte

    rnal

    tel

    epho

    nes

    Bina

    ry s

    witc

    hing

    dev

    ice

    General

    Name • • • • • • • • • • • • • • •

    Description • • • • • • • • • • • • • • •

    Address (KNX) - - - - - - - - - - - - - - •

    Data type (KNX) - - - - - - - - - - - - - - •

    Call number (Internal) • • • • • • • • • • • • • - -

    Assignment • • • • • • • • • • • • • • -

    Software type - - - - - - • • • • • - - - -

    Account name - - - - - - • • • • • - - - -

    Password (info field: Password is adopted from the user.)

    - - - - - - • • • • • • • - -

    Using as an autonomous telephone - - - - - - • • • - - - - - -

    CTI device - - - - - - • • • - - - - - -

    MAC address • • • • • • - - - - - - - - -

    Installation type (Wall / table) - • • • • • - - - - - - - - -

    Hardware revision • • • • • • - - - - - • • - -

    Activate building automation * - - - - - • - - - - - - - - -

    URL building automation * - - - - - • - - - - - - - - -

    Ringtone volume - • • • • • - - - - - - - - -

    Speech volume • • • • • • - - - - - - - - -

    Display time at the terminal - • • • • • - - - - - - - - -

    Microphone sensitivity • - - - - - - - - - - - - - -

    Camera available • - - - - - - - - - - - - - -

    Telephone script • • • • • • • • • • • • • • -

    Size of audio frame [ms] - - - - - - - - - - - • • - -

    Acoustic button acknowledgements • - - - - - - - - - - - - - -

    Line prefix and (external) call number - - - - - - - - - - • - - • -

  • 49

    ATL

    C 6

    70-…

    AH

    F 87

    0-…

    AH

    FV 8

    70-…

    AH

    T 87

    0-…

    AH

    TV 8

    70-…

    AV

    P 87

    0-…

    ASC

     170

    -…

    ASH

    T 17

    0-…

    ASM

     170

    -…

    Sied

    le A

    pp iP

    ad

    Sied

    le a

    pp iP

    hone

    SIP

    vide

    o te

    leph

    one

    SIP

    audi

    o te

    leph

    one

    Exte

    rnal

    tel

    epho

    nes

    Bina

    ry s

    witc

    hing

    dev

    ice

    Button configuration

    Expert mode - • • • • - - - - - - - - - -

    Single click - • • • • - - - - - - - - - -

    Double click - • • • • - - - - - - - - - -

    Press button - • • • • - - - - - - - - - -

    Release button - • • • • - - - - - - - - - -

    Entrance door light •

    Buttons (The number is dependent on the equipment of the door stations)

    • - - - - - - - - - - - - - -

    Door release button / 2–8 - • • • • - - - - - - - - - -

    Button / tile 1–44 - - - - - • - - - - - - - - -

    Switching outputs/inputs

    Voltage mode output 23,24 • - - - - - - - - - - - - - -

    O